Instruction/ maintenance manual of the product BVD34FP50 Empire Comfort Systems
Go to page of 40
Page 1 19400-3-0406 B-VENT GAS FIREPLACE MODEL SERIES MILLIVOL T BVD34FP30(F ,L)N-1 BVD36FP32(F ,L)N-1 BVP42FP32(F ,L)N-1 DIRECT IGNITION BVD34FP50(F ,L)N-1 BVD36FP52(F ,L)N-1 BVP42FP52(F ,L)N-1 EFFECTIVE DA TE APRIL 2006 UL FILE NO.
Page 2 19400-3-0406 Important Safety Information .................................................................................................... 3 Safety Information for Users of LP Gas ............................................................
Page 3 19400-3-0406 Before enclosing the vent pipe assembly , operate the appliance to ensure it is venting pr operly . • If this appliance is installed directly on carpeting, tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.
Page 4 19400-3-0406 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in pr opane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor .
Page 5 19400-3-0406 Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty card supplied with the fireplace. 3. Installer should show owner how to start and operate the fireplace.
Page 6 19400-3-0406 Figure 1 Dim BVD34 BVD36 BVP42 A 37" 940mm 39" 990mm 43" 1092mm B 34" 864 mm 36" 914mm 40" 1,016mm C 22 7/8" 581mm 24 7/8" 632mm 24 7/8".
Page 7 19400-3-0406 Mantel Chart (Figure 3) Figure 3 Clearances (Figure 4) Clearance from top front edge of fireplace to ceiling is 36" Clearance from side of fireplace to adjacent sidewall is 6".
Page 8 19400-3-0406 Figure 6 The gas pipeline can be brought in through the right or left side of the appliance. Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/CGA-B149 (.1 or .2) installation code. Installing a New Main Gas Cock Each appliance should have its own manual gas cock.
Page 9 19400-3-0406 FROM FRONT OF APPLIANCE TO GAS LINE HOLE 3 ½” GAS LINE HOLE BVD34 SERIES - 10” BVD,P (36,42) - 13 ½” Figure 7 BURNER ASSEMBL Y REAR T A B (BURNER BASE) LOCA TIONS FLEXIBLE .
Page 10 19400-3-0406 Framing dimension "A" includes a three inch clearance for standoffs on fir ebox. Framing and Finishing 1. Choose unit location. 2. Frame in fireplace with a header across the top. It is important to allow for the finished face thickness when setting the depth of the frame.
Page 1 1 19400-3-0406 Note: Dimension "C" is the minimum with the fireplace face extending 1/2" in front of the framing to allow for finishing materials. Figure 1 1 Attention: Add 3-3/4" to “A” dimensions when using a flush mantel base.
Page 12 19400-3-0406 V ent Runs In planning the installation for the fireplace, it is necessary to install certain components before the appliance is completely positioned and installed. These include the vent system, gas piping for the appliance, Fresh Air Kit, and the electrical wiring.
Page 13 19400-3-0406 V ent Size Model BVD34FP series uses a 4" B-V ent for operation. Models BVD36FP and BVP42FP series use a 6" B-V ent for operation.
Page 14 19400-3-0406 1 4 5 3 2 Before you begin: if you are installing logs into the BVD34 or BVD36 model, then this fireplace is supplied with a set of five ceramic fiber logs. Do not handle these logs with your bare hands! Always wear gloves to prevent skin irritation from ceramic fibers.
Page 15 19400-3-0406 W ARNING : Failure to position the parts in accordance with this diagram or failure to use only parts specifically approved with this appliance may result in property damage or personal injury . Attenti on: Do not use Figure 19 or Figure 20 to order logs.
Page 16 19400-3-0406 The OWNER should carefully read and follow these operating instructions at all times. Lower the door assembly to view the gas controls for the fireplace. Initial Lighting Upon completing the gas line or turning the gas valve on after it has been in the “OFF” position, a small amount of air will be in the lines.
Page 17 19400-3-0406 ST ANDING PILOT OPERA TING INSTRUCTIONS The fireplace is equipped with a 15 foot length of wire that can be used to connect the valve to a wall switch (installer provided) or remote control receiver .
Page 18 19400-3-0406 Figure 23 THERMOPILE GAS V AL VE (OPTIONAL) REMOTE CONTROL RECEIVER DU RECEPTEUR (F ACUL T A TIVE) CONTROLE E DIST ANCE W ALL SWITCH INTERRUPTEUR MURAL (OPTIONAL) THERMOST A T (F .
Page 19 19400-3-0406 1. STOP! Read the safety information above. 2. Set wall switch or r emote to "OFF ." 3 . T urn off all electric power to the appliance (if applicable). 4. Open bottom louver assembly , or open valve access door . 5. Push in gas control knob slightly and turn clockwi se to "OFF .
Page 20 19400-3-0406 With proper installation and maintenance, your new Gas Fireplace will provide years of trouble-free service. If you do experi- ence a problem, refer to the T rouble Shooting Guide below . This guide will assist a qualified service person in the diagnosis of problems and the corr ective action to be taken.
Page 21 19400-3-0406 "B-VENT" FIREPLACES Model Conversion Kit Model (Part Number) BVD34FP3 SERIES BVCK34P (19160) BVD36FP3 SERIES BVCK36P (19161) BVP42FP3 SERIES BVCK42P (19162) FOR CONVERSION T O LIQUEFIED PETROLEUM GAS W ARNING This conversion kit is to be installed by an Empire Comfort Sys tems, Inc.
Page 22 19400-3-0406 BURNER ORIFICE CONVERSION - Slope style burners 8b . On model BVP42FP3 series fireplaces, you will have a rectangular slope style burner . T o gain access to the main orifice, disconnect the gas supply tubing at the air shutter .
Page 23 19400-3-0406 LED LIGHT LED LUMIÈRE BLACK NOIR GREEN VERT WHITE BLANC RED ROUGE BLACK NOIR GAS V AL VE V AL VE D E GAZ (OPTIONAL) WALL SWITCH INTERRUPTEUR MURAL (F ACUL T A TIVE) 120 V AC LINE.
Page 24 19400-3-0406 A. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor . WHA T T O DO IF YOU SMELL GAS • Do not try to light any appliance • Do not touch any electrical switch • Do not use any phone in your building.
Page 25 19400-3-0406 With proper installation and maintenance, your new Gas Fireplace will provide years of trouble-free service. If you do experience a problem, refer to the troubleshooting guide below. This guide will assist a qualified service person in the diagnosis of problems and the corrective action to be taken.
Page 26 19400-3-0406 1. T urn off the gas supply . 2 . Turn off the electrical supply to the appliance if so equipped. 3. Open or remove glass doors if applicable. 4. Remove top louver and lower bottom louver . 5. Remove logs from burner assembly . V AL VE CONVERSION 6.
Page 27 19400-3-0406 PLEASE NOTE It is normal for appliances fabricated of steel to give off some expansion and/or contraction noise during the start up or cool down cycle. Similar noises ar e found with your furnace heat exchanger or car engine. It is not unusual for your gas fireplace to give off some odor the first time it is burned.
Page 28 19400-3-0406 USE ONL Y MANUF ACTURER’S REPLACEMENT P ARTS. USE OF ANY OTHER P ARTS COULD CAUSE INJUR Y OR DEA TH. INDEX NO. P AR T NUMBER DESCRIPTION BVD34L BVD34F BVD36L BVD36F 1 19506 1950.
Page 29 19400-3-0406 8 7 6 5 4 2 3 1 8 9 9 10 1 1 12 13 14 15 16 17 18 19 20 21 22 23 24 26 27 28b 25 19 17 18 26 27 28a 21 20 15 29a 30 31 32 33 35a 34 35b 36 37 38 39 16 22 29b 40 41 DIRECT IGNITION.
Page 30 19400-3-0406 INDEX NO. P AR T NUMBER P AR T NUMBER DESCRIPTION BVP42L BVP42F 1 19508 19508 TOP SHIELD 2 17247 17247 TOP ST ANDOFF (2 REQUIRED) 3 10554 10554 NAILING FLANGE (4 REQUIRED) 4 M178 .
Page 31 19400-3-0406 8 7 6 5 4 2 3 1 8 9 9 10 1 1 12 13 14 21 22 29b 28a 29a 30 21 20a 31 32 33 34 35a 35b 36 37 38 39 DIRECT IGNITION BURNER ASSEMBL Y MILLIVOL T BURNER ASSEMBL Y 3 PIECE LOG ASSEMBL .
Page 32 19400-3-0406 Attention : Install blower assembly before connecting gas inlet supply line Note : Junction box on right side of fireplac e must be pre-w ired at time of fireplace installation for use with blower assembly .
Page 33 19400-3-0406 110 VOLT AC JUNCTION BOX WHITE SPEED CONTROL F A N SWITCH GROUND BLACK F A N 1 FBB4 BLOWER ASSEMBL Y COMPLETE 2 R7649 F AN CONTROL 3 R4192 SPEED CONTROL KNOB 4 R4186 SPEED CONTROL.
Page 34 19400-3-0406 CAUT ION: ALL WIRI NG SHOUL D BE DONE BY A QUALI FIED ELECTRI CIAN AND SHALL BE IN COMP LIANCE WITH ALL LOCAL, CITY AND ST A TE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THA T MA IN PO WER SU PPL Y IS DI SCO NNE CT ED.
Page 35 19400-3-0406 The following accessory parts can be obtained from your Empire Comfort Systems dealer . If you need additional information beyond what your dealer can furnish, contact Empire Comfort Systems Inc., Nine Eighteen Freeburg A ve., Belleville, Illinois 62220-2623.
Decorative Louver Mission Decorative Louver Arch Decorative Louver Leaf Decorative Frame Rectangle with hinges Decorative Door Leaf Rectangle Decorative Door Mission Rectangle Decorative Door Plain Re.
Page 37 19400-3-0406 Parts can be ordered only through your service person or dealer . For best results, the service person or dealer should order parts through the distributor . Parts can be shipped directly to the service person/dealer . All parts listed in the Parts List have a Part Number .
Page 38 19400-3-0406 SER VICE NOTES.
Page 39 19400-3-0406 SER VICE NOTES.
Page 40 19400-3-0406 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.
An important point after buying a device Empire Comfort Systems BVD34FP50 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Empire Comfort Systems BVD34FP50 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Empire Comfort Systems BVD34FP50 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Empire Comfort Systems BVD34FP50 you will learn all the available features of the product, as well as information on its operation. The information that you get Empire Comfort Systems BVD34FP50 will certainly help you make a decision on the purchase.
If you already are a holder of Empire Comfort Systems BVD34FP50, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Empire Comfort Systems BVD34FP50.
However, one of the most important roles played by the user manual is to help in solving problems with Empire Comfort Systems BVD34FP50. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Empire Comfort Systems BVD34FP50 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center