





If your electronics application is one of the many that
requires continuous operation — without tolerance for even
scheduled downtime — you need the reliability provided by
Modeled on proven UPS technology, the Liebert SmartSwitch point-of-use power transfer switch is placed at the most effective spot — the last connection upstream of the protected equipment — allowing dual AC power paths all the way up to the critical load. From design to operation and maintenance, Liebert SmartSwitch has the features that optimize power availability:
dual power sources.
Many of today’s servers and other computing systems are equipped with dual power cords…designed to provide built-in redundancy by allowing connection to two separate power sources. In a similar move, facilities are now introducing this level of dual cord reliability to critical equipment that operates on a single power input by supplying two independent electrical feeds. The key to making it all work, however, is to have a dependable switching mechanism to support it.

The transfer switch should have proven technology and design features to ensure that it will operate dependably when you need it. The swihching mechanism should be easy to configure, install, use and maintain.
A switch needs to operate swiftly and reliably enough to compensate for “fast” power failures such as UPS system failure, circuit breaker trip or operator error — without affecting operation of the protected equipment.
The Liebert SmartSwitch does exactly this by providing rapid switching between two independent AC power sources, for uninterrupted operation of critical electronic equipment.
making power transfer time invisible to your protected equipment.
eliminate connecting together of the independent power sources, even under faulted conditions.

Liebert SmartSwitch provides automatic or manual transfer between dual utility or UPS sources, allowing dual AC power paths all the way up to the critical load.


Three different configurations allow the unit to be placed under a raised floor, mounted on a wall or used in a rack, based on your site needs.
Convenient, from selection to maintenance.

available to match your load specifications, simplifying system installation and setup.
I Selectable preferred input feature allows you to
determine the normal and alternate power source of your choice without rewiring or load shutdown.
provides a safe and fast solution to servicing the Liebert SmartSwitch without disturbing your protected equipment.
feature allow your protected equipment to remain up and running, even when the Liebert SmartSwitch module is being replaced or serviced.
STATUS CONTACTS CONNECTOR
RS-232 CONNECTOR
I LED indicators provide at-a-glance operating status.
Eight output contacts are available for remote status indication. RS232 ASCII communications port allows setpoint control and remote monitoring.
3.15"
3.76"
2.25" 2.25"
1/2" KNOCKOUT 0.88" (22mm) (3 PLACES)
I ETL Listed to UL Standard 1008 for safety.
I CE Mark (50 Hz) — complies with EMC and low voltage

directives.
11.1"
Liebert SmartSwitch includes manual transfer test capability to assure continued proper operation.
The unit is available with your choice of receptacles and connector,simplifying installation and setup.
25.4" 26.9"
INPUT, OUTPUT AND CONTROL CONNECTIONS LOCATED BEHIND REMOVABLE ACCESS DOORS
M C B A M C B A M C B A DO DO DO

10.7" 2.5"
AIR INTAKE 2 SIDES
RIGHT SIDE VIEW

RELAY CONTACTS
& RS-232
PORT
With separate sections for power connections and electronics, Liebert SmartSwitch can sustain power to the load even when the electronics module is being swapped for service.
Source 1 Source 2 Output
LED indicators provide at-a-glance operating status. Eight output contacts are available for remote status indication. RS232 ASCII communications port allows setpoint control and remote monitoring.
Hot swappable electronics module and bypass feature allow your protected equipment to remain up and running, even when the SmartSwitch is being serviced.
Logic and Power Supplies


1050 Dearborn Drive P.O. Box 29186 Columbus, Ohio 43229 800 877 9222 Phone (U.S. & Canada Only) 614 888 0246 Phone (Outside U.S.) 614 841 6022 FAX
Technical Specifications
Freq No. of Conductors Breaker Size* Amps Enc. Model Recept. Voltage Hz, Ph. Neu. Gnd Poles Amps Cont. Type
Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco (PD) Italy 39 049 9719 111 Phone 39 049 5841 257 FAX
SSIBMAR01 3743 208 60 2 — 1 2 20 16 R SSIBMBU01 3744 208 60 3 — 1 3 15 12 U SSIBMCU01 3753 208 60 2 — 1 2 30 24 U SSIBMDU01 3754 208 60 3 — 1 3 30 24 U SSIBMEU01 7324 208 60 3 — 1 3 60 48 U SS420R9VU01 420R9V 208 60 3 — 1 3 20 16 U SS430R9VU01 430R9V 208 60 3 — 1 3 30 24 U SS460R9VU01 460R9V 208 60 3 — 1 3 60 48 U SS360R6WU01 360R6W 208 60 2 — 1 2 60 48 U SS515R2R01 5262 120 60 15 12 R SS515R4R01 (2) 5262 120 60 15 12 R SS520R2R01 5392CN 120 60 1 20 16 R SS520R4R01 (2) 5392CN 120 60 1 20 16 R SS530R1U01 9308 120 60 1 30 24 U SS615R2R01 5662 208 60 2 — 1 2 15 12 R SS620R2R01 6392CN 208 60 2 — 1 2 20 16 R SS630R1U01 9330 208 60 2 — 1 2 30 24 U SS1420R1U01 8410 120/208 60 2 1 1 2 20 16 U SS1430R1U01 9430 120/208 60 2 1 1 2 30 24 U SS1520R1U01 8420 208 60 3 — 1 3 20 16 U SSL515R1R01 4710 120 60 15 12 R SSL515R2R01 4700 120 60 15 12 R SSL520R1R01 2310 120 60 1 20 16 R SSL520R2R01 (2) 2310 120 60 1 20 16 R SSL530R1U01 2610 120 60 1 30 24 U SSL615R1R01 4560 208 60 2 — 1 2 15 12 R SSL615R2R01 4550 208 60 2 — 1 2 15 12 R SSL620R1R01 2320 208 60 2 — 1 2 20 16 R SSL620R2R01 (2) 2320 208 60 2 — 1 2 20 16 R SSL630R1U01 2620 208 60 2 — 1 2 30 24 U SSL1420R1U01 2410 120/208 60 2 1 1 2 20 16 U SSL1430R1U01 2710 120/208 60 2 1 1 2 30 24 U SSL1520R1U01 2420 208 60 3 — 1 3 20 16 U SSL1530R1U01 2720 208 60 3 — 1 3 30 24 U SSL2120R1U01 2510 120/208 60 3 1 1 3 20 16 U SSL2130R1U01 2810 120/208 60 3 1 1 3 30 24 U SSFW120R01 none 120 60 1 20 16 R SSFW130U01 none 120 60 1 30 24 U SSFW220R01 none 208 60 2 — 1 2 20 16 R SSFW220NU01 none 120/208 60 2 1 1 2 20 16 U SSFW230U01 none 208 60 2 — 1 2 30 24 U SSFW230NU01 none 120/208 60 2 1 1 2 30 24 U SSFW320U01 none 208 60 3 — 1 3 20 16 U SSFW320NU01 none 120/208 60 3 1 1 3 20 16 U SSFW330U01 none 208 60 3 — 1 3 30 24 U SSFW330NU01 none 120/208 60 3 1 1 3 30 24 U SSFW360U01 none 208 60 3 — 1 3 60 48 U SSFW360NU01 none 120/208 60 3 1 1 3 60 48 U SSFW360NW01 none 120/208 60 3 1 1 3 60 48 W SSFW360NX01 none 120/208 60 3 1 1 3 60 48 W SSFW116R01x none 230 50 16 16 R SSFW150U01x none 230 50 1 50 50 U SSFW325U01x none 400 50 3 — 1 3 25 25 U SSFW325NU01x none 400/230 50 3 1 1 3 25 25 U SSFW350U01x none 400 50 3 — 1 3 50 50 U SSFW350W01x none 400 50 3 — 1 3 50 50 W SSFW350X01x none 400 50 3 — 1 3 50 50 W
Emerson Network Power Asia Pacific 7/F., Dah Sing Financial Centre 108 Gloucester Rd, Wanchai Hong Kong 852 25722201 Phone 852 28029250 FAX
24 x 7 Tech Support
800 222 5877 Phone 614 841 6755 (outside U.S.)
While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
© 2007 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.
® Liebert and the Liebert logo are registered trademarks of the Liebert Corporation.
SL-20300 (R10/07) Printed in USA
Emerson Network Power. The global leader in enabling Business-Critical Continuity™.
AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection
* Supply branch breaker not included in Liebert SmartSwitch. Consult factory for other recepticles.
Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2007 Emerson Electric Co.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.