Table of Contents 200 sections Regulatory Agency Warnings & Notices · Contents · Figures · Tables · … ShowHide
Regulatory Agency Warnings & Noticesp.3Contentsp.7Figuresp.11Tablesp.13Registersp.15Overviewp.17Components and Featuresp.17Functional Overviewp.17Physical Memory Mapp.18Additional Informationp.20Product Certificationp.20RoHS Compliancep.22Terminology and Notationp.22Technical Referencesp.22Setupp.25Electrostatic Dischargep.25PmT1 and PmE1 Circuit Boardp.25Connectorsp.28Installationp.28PmT1 and PmE1 Setupp.29Power Requirementsp.29Environmental Considerationsp.30Reset Methodsp.30Troubleshootingp.30Technical Supportp.31Product Repairp.32Central Processing Unitp.33MPC860P Initializationp.33MPC860P Exception Handlingp.35CPU Interruptsp.36System Interface Unit (SIU)p.36Timebase Counterp.37Decrementer Counterp.37Software Resetp.37MPC860 Parallel Port configurationp.37Optional BDM Headerp.38On-Card Memory Configurationp.41Socketed Flashp.41I2C EEPROMp.41I2C EEPROM Operationp.42Emerson Memory Mapp.42On-card DRAMp.42On-card Memory Sizing and Typep.43DRAM Timingp.43Serial I/Op.45The Communications Processor Modulep.45CPM Register Initialization Formatp.46RISC Controllerp.46CPM Interrupt Handlingp.47Dual-Port RAMp.47General Purpose Timersp.48Independent DMA (IDMA) Channelsp.48Serial DMA (SDMA) Channelsp.48MPC860P Serial Interfacep.48Serial Communication Controllers (SCC)p.49Serial Management Controllers (SMC)p.49Time Slot Assigner (TSA)p.49UART Baud Rate Selectionp.50Serial Connector Pin Assignmentsp.51TDM Interfacep.53The T1 or E1 Line Interfacep.56Configuring the T1 or E1 Interfacep.57The T1 FDL Interfacep.57The Management Data Interface (MDI)p.59Front Panel I/Op.60PMC/PCI Interfacep.63PCI9060ES Register Mapp.63PCI Configuration Registersp.63Local Configuration Registersp.64Shared Runtime Registersp.65PCI9060ES Initializationp.65Deadlocked Cyclesp.68Retries on Local Direct Master Cyclesp.68Retries on Direct Slave Cycles.p.68Assigning Prioritiesp.68Controlling Access Latencyp.69Avoiding the PCI9060ES Phantom Readp.69Managing Bandwidthp.70Bridge to Bridge Considerationsp.70PCI Interruptsp.70PCI Bus Interfacep.70PMC Connector Pin Assignmentsp.70PCI Bus Control Signalsp.72Monitorp.75Power-up/Reset Sequencep.75Start-up Displayp.78Command-line Historyp.79Command-line Editorp.79Initializing Memoryp.80Command Syntaxp.80Initializing Memoryp.81Command Syntaxp.81Typographic Conventionsp.81Boot Commandsp.81bootbusp.81bootepromp.82bootromp.83bootserialp.83Help Commandsp.84helpp.84Memory/Register Commandsp.84checksummemp.84clearmemp.84cmpmemp.84copymemp.84displaymemp.85fillmemp.85findmemp.85findnotmemp.85findstrp.85readmemp.85setmemp.86swapmemp.86testmemp.86ump.86writememp.86writestrp.87NVRAM Commandsp.87nvdisplayp.87nvinitp.88nvopenp.88nvsetp.88nvupdatep.89Configuring the Default Boot Devicep.89Power-up Diagnostic/Test Commandsp.91cachetestp.92eepromtestp.92memtestp.92Remote Host Commandsp.92callp.93downloadp.93Binary Download Formatp.93transmodep.94Configuring the Download Portp.94Hex-Intel Formatp.95Extended Address Recordp.95Data Recordp.96End-of-file Recordp.96Motorola S-record Formatp.98S0-records (User Defined)p.98S1-S2-and S3-records (Data Records)p.99S5-records (Data Count Records)p.99S7-S8-and S9-records (Termination and Start Address Records)p.100Utilitiesp.101configboardp.101Arithmetic Commandsp.101addp.101divp.101mulp.102randp.102subp.102Errors and Screen Messagesp.102Monitor Function Referencep.103PmT1 and PmE1-Specific Functionsp.104ChangeBaudp.104EEPROMAccp.104getcharp.104InitBoardp.105Miscp.105NvHkOffsetp.106NvRamAccp.106SetUnExpIntFunctp.107MPC860P-Specific Functionsp.107Cachep.107Exceptionsp.107Interruptsp.109Statusp.110Standard Monitor Functionsp.110atohp.110BootUpp.111InitFifop.112IsLegalp.112MemMngp.113NVSupportp.114Seedp.116Serialp.116TestSuitep.118xprintfp.119Acronymsp.121Indexp.123Ap.123Bp.123Cp.123Dp.123Ep.123Fp.123Gp.123Hp.124Ip.124Kp.124Lp.124Mp.124Np.125Pp.125Rp.125Sp.125Tp.126Up.126Vp.126Wp.126
Page 1 of the Emerson Power Module (PME1) user manual — PmT1 and PmE1: High Speed T1 and E1 Interface Module
Page 1 · click to enlarge
Page 1
Emerson Power Module (PME1) diagram (page 1)
Fig. 1

User’s Manual from Emerson Network Power™ Embedded Computing

PmT1 and PmE1: High Speed T1 and E1 Interface Module

Page 2 of the Emerson Power Module (PME1) user manual — Revision Level: Principal Changes: Date:
Page 2 · click to enlarge
Page 2

The information in this manual has been checked and is believed to be accurate and reliable. HOWEVER, NO RESPONSIBILITY IS ASSUMED BY EMERSON NETWORK POWER, EMBEDDED COMPUTING FOR ITS USE OR FOR ANY INACCURACIES. Specifications are subject to change without notice. EMERSON DOES NOT ASSUME ANY LIABILITY ARISING OUT OF USE OR OTHER APPLICATION OF ANY PRODUCT, CIRCUIT, OR PROGRAM DESCRIBED HEREIN. This document does not convey any license under Emerson patents or the rights of others.

Emerson. Consider It Solved is a trademark, and Business-Critical Continuity, Emerson Net- work Power, and the Emerson Network Power logo are trademarks and service marks of Emerson Network Power, Embedded Computing, Inc. © 2007 Emerson Network Power, Embedded Computing, Inc.

Revision Level: Principal Changes: Date:

10002367-00 Original release March 2001

10002367-01 RoHS 5-of6 compliance, ECR000272 March 2006

10002367-02 Artwork rev.-33 December 2007

Copyright © 2007 Emerson Network Power, Embedded Computing, Inc. All rights reserved.

Page 3 of the Emerson Power Module (PME1) user manual — FCC RULES AND REGULATIONS — PART 68
Page 3 · click to enlarge
Page 3
Emerson Power Module (PME1) — Regulatory Agency Warnings & Notices diagram (page 3)
Fig. 2 · Regulatory Agency Warnings & Notices

The Emerson PmT1 and PmE1 meets the requirements set forth by the Federal Communi- cations Commission (FCC) in Title 47 of the Code of Federal Regulations. The following information is provided as required by this agency.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

FCC RULES AND REGULATIONS — PART 15

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reason- able protection against harmful interference when the equipment is operated in a commer- cial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful inter- ference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interfer- ence at his own expense.

consent of Emerson Network Power could invalidate the user’s authority to operate this equipment.

EMC COMPLIANCE

The electromagnetic compatibility (EMC) tests used a PmT1 and PmE1 model that includes a front panel assembly from Emerson Network Power.

front panel has been removed, your system chassis/enclosure must provide the required electromagnetic interference (EMI) shielding to maintain EMC compliance.

FCC RULES AND REGULATIONS — PART 68

This equipment complies with Part 68 of the FCC rules. There is a label on the PmT1 and PmE1 board that contains the FCC registration number. If requested, this information must be provided to the telephone company.

10002367-02 PmT1 and PmE1 User’s Manual i

! · !

Page 4 of the Emerson Power Module (PME1) user manual — Regulatory Agency Warnings & Notices
Page 4 · click to enlarge
Page 4
Emerson Power Module (PME1) — Regulatory Agency Warnings & Notices diagram (page 4)
Fig. 3 · Regulatory Agency Warnings & Notices
This board is designed to be connected to the telephone network or premises wiring using a compatible modular jack which is Part 68 compliant. This board cannot be used on telephone company-provided coin service. Connection to Party Line Service is subject to state tariffs. If this board causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. If advance notice is not practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary modifications in order to maintain uninterrupted service. It is recommended that the customer install an AC surge arrestor in the AC outlet to which this device is connected. This is to avoid damaging the equipment caused by local lightening strikes and other electrical surges. The following table lists each applicable Facility Interface Code (FIC) along with the Service Order Code (SOC) and connector jack type for the PmT1 and PmE1. Facility Interface FIC Service Order Jack Board Name: Code (FIC): Description: Code (SOC): Type: PmT1 and PmE104DU9.BN 04DU9.DN 04DU9.1KN 04DU9.1SN1.54 Mbps AMI Superframe Format (SF) without line power 1.544 Mbps SF and B8ZF without line power 1.544 Mbps AMI ESF without line power 1.544 Mbps AMI ESF and B8ZS without line power6.0NaRJ48C a. Combinations of equipment provide full protection to digital service. Billing protection and encoded analog protection are provided either by including auxiliary equipment within the registration envelope or by use of a separately registered device. Note: The following information and instructions must be given to the final assembler/end user. The mounting of the PmT1 and PmE1 in the final assembly must be made so that the PmT1 and PmE1 is isolated from exposure to hazardous voltages within the assembly. Adequate separation and restraint of cables and cords must be provided. The circuitry from the PmT1 and PmE1 to the telephone line must be provided in wiring that carries no other circuitry that is specifically allowed in the rules, such as PR and PC leads. PC board traces carrying tip and ring leads shall have sufficient spacing to avoid surge breakdown.

PmT1 and PmE1 User’s Manual 10002367-02 ii

Page 5 of the Emerson Power Module (PME1) user manual — INDUSTRY CANADA RULES AND REGULATIONS — CS03
Page 5 · click to enlarge
Page 5
Emerson Power Module (PME1) — Regulatory Agency Warnings & Notices diagram (page 5)
Fig. 4 · Regulatory Agency Warnings & Notices

Information shall be provided as to the power source requirements. See the PmT1 and PmE1 power requirements in the hardware manual.

If the device is enclosed in an assembly, and not readily accessible, a label shall be placed on the exterior of the cabinet listing the registration number of each PmT1 and PmE1 con- tained therein.

The final assembler shall provide, in the consumer instructions, all applicable Network Con- nection Information.

INDUSTRY CANADA RULES AND REGULATIONS — CS03

Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situ- ations.

Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to dis- connect the equipment.

Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines, and internal metallic water pipe system, if present, are con- nected together. This precaution may be particularly important in rural areas.

appropriate electric inspection authority, or electrician as appropriate.

The standard connecting arrangement code (telephone jack type) for this equipment is CA48C.

10002367-02 PmT1 and PmE1 User’s Manual iii

!

Page 6 of the Emerson Power Module (PME1) user manual — EC Declaration of Conformity
Page 6 · click to enlarge
Page 6
Emerson Power Module (PME1) — Regulatory Agency Warnings & Notices diagram (page 6)
Fig. 5 · Regulatory Agency Warnings & Notices

EC Declaration of Conformity

According to EN 45014:1998

Manufacturer’s NameEmerson Network Power Embedded Computing
Manufacturer’s Address8310 Excelsior Drive Madison, Wisconsin 53717

Declares that the following product, in accordance with the requirements of 2004/108/EEC, EMC Directive and 1999/5/EC, RTTE Directive and their amending directives,

ProductPMC Module
Model Name/NumberPmT1 and PmE1/01439143-xx

has been designed and manufactured to the following specifications:

EN55022:1998 Information Technology Equipment, Radio disturbance characteristics, Limits and methods of measurement

EN55024:1998 Information Technology Equipment, Immunity characteristics, Limits and methods of measurement

EN300386 V.1.3.1 Electromagnetic compatibility and radio spectrum matters (ERM); Telecommunication network equipment; EMC requirements

As manufacturer we hereby declare that the product named above has been designed to comply with the relevant sections of the above referenced specifications. This product complies with the essential health and safety requirements of the EMC Directive and RTTE Directive. We have an inter- nal production control system that ensures compliance between the manufactured products and the technical documentation.

Emerson Power Module (PME1) — EC Declaration of Conformity diagram (page 6)
Fig. 6 · EC Declaration of Conformity

Bill Fleury Compliance Engineer

Issue dateDecember 14, 2007

PmT1 and PmE1 User’s Manual 10002367-02 iv

Page 7 of the Emerson Power Module (PME1) user manual — Table of Contents
Page 7 · Contents
Contents

Contents

Regulatory Agency Warnings & Noticesp.3Contentsp.7Figuresp.11Tablesp.13Registersp.15Overviewp.17Components and Featuresp.17Functional Overviewp.17Physical Memory Mapp.18Additional Informationp.20Product Certificationp.20RoHS Compliancep.22Terminology and Notationp.22Technical Referencesp.22Setupp.25Electrostatic Dischargep.25PmT1 and PmE1 Circuit Boardp.25Connectorsp.28Installationp.28PmT1 and PmE1 Setupp.29Power Requirementsp.29Environmental Considerationsp.30Reset Methodsp.30Troubleshootingp.30Technical Supportp.31Product Repairp.32Central Processing Unitp.33MPC860P Initializationp.33MPC860P Exception Handlingp.35CPU Interruptsp.36System Interface Unit (SIU)p.36Timebase Counterp.37Decrementer Counterp.37Software Resetp.37MPC860 Parallel Port configurationp.37Optional BDM Headerp.38On-Card Memory Configurationp.41Socketed Flashp.41I2C EEPROMp.41I2C EEPROM Operationp.42Emerson Memory Mapp.42On-card DRAMp.42On-card Memory Sizing and Typep.43DRAM Timingp.43Serial I/Op.45The Communications Processor Modulep.45CPM Register Initialization Formatp.46RISC Controllerp.46CPM Interrupt Handlingp.47Dual-Port RAMp.47General Purpose Timersp.48Independent DMA (IDMA) Channelsp.48Serial DMA (SDMA) Channelsp.48MPC860P Serial Interfacep.48Serial Communication Controllers (SCC)p.49Serial Management Controllers (SMC)p.49Time Slot Assigner (TSA)p.49UART Baud Rate Selectionp.50Serial Connector Pin Assignmentsp.51TDM Interfacep.53The T1 or E1 Line Interfacep.56Configuring the T1 or E1 Interfacep.57The T1 FDL Interfacep.57The Management Data Interface (MDI)p.59Front Panel I/Op.60PMC/PCI Interfacep.63PCI9060ES Register Mapp.63PCI Configuration Registersp.63Local Configuration Registersp.64Shared Runtime Registersp.65PCI9060ES Initializationp.65Deadlocked Cyclesp.68Retries on Local Direct Master Cyclesp.68Retries on Direct Slave Cycles.p.68Assigning Prioritiesp.68Controlling Access Latencyp.69Avoiding the PCI9060ES Phantom Readp.69Managing Bandwidthp.70Bridge to Bridge Considerationsp.70PCI Interruptsp.70PCI Bus Interfacep.70PMC Connector Pin Assignmentsp.70PCI Bus Control Signalsp.72Monitorp.75Power-up/Reset Sequencep.75Start-up Displayp.78Command-line Historyp.79Command-line Editorp.79Initializing Memoryp.80Command Syntaxp.80Initializing Memoryp.81Command Syntaxp.81Typographic Conventionsp.81Boot Commandsp.81bootbusp.81bootepromp.82bootromp.83bootserialp.83Help Commandsp.84helpp.84Memory/Register Commandsp.84checksummemp.84clearmemp.84cmpmemp.84copymemp.84displaymemp.85fillmemp.85findmemp.85findnotmemp.85findstrp.85readmemp.85setmemp.86swapmemp.86testmemp.86ump.86writememp.86writestrp.87NVRAM Commandsp.87nvdisplayp.87nvinitp.88nvopenp.88nvsetp.88nvupdatep.89Configuring the Default Boot Devicep.89Power-up Diagnostic/Test Commandsp.91cachetestp.92eepromtestp.92memtestp.92Remote Host Commandsp.92callp.93downloadp.93Binary Download Formatp.93transmodep.94Configuring the Download Portp.94Hex-Intel Formatp.95Extended Address Recordp.95Data Recordp.96End-of-file Recordp.96Motorola S-record Formatp.98S0-records (User Defined)p.98S1-S2-and S3-records (Data Records)p.99S5-records (Data Count Records)p.99S7-S8-and S9-records (Termination and Start Address Records)p.100Utilitiesp.101configboardp.101Arithmetic Commandsp.101addp.101divp.101mulp.102randp.102subp.102Errors and Screen Messagesp.102Monitor Function Referencep.103PmT1 and PmE1-Specific Functionsp.104ChangeBaudp.104EEPROMAccp.104getcharp.104InitBoardp.105Miscp.105NvHkOffsetp.106NvRamAccp.106SetUnExpIntFunctp.107MPC860P-Specific Functionsp.107Cachep.107Exceptionsp.107Interruptsp.109Statusp.110Standard Monitor Functionsp.110atohp.110BootUpp.111InitFifop.112IsLegalp.112MemMngp.113NVSupportp.114Seedp.116Serialp.116TestSuitep.118xprintfp.119Acronymsp.121Indexp.123Ap.123Bp.123Cp.123Dp.123Ep.123Fp.123Gp.123Hp.124Ip.124Kp.124Lp.124Mp.124Np.125Pp.125Rp.125Sp.125Tp.126Up.126Vp.126Wp.126
Page 11 of the Emerson Power Module (PME1) user manual — Figures
Page 11 · click to enlarge
Page 11
Emerson Power Module (PME1) — Figures diagram (page 11)
Fig. 7 · Figures

Figure 1-1: General System Block Diagram 1-2

Figure 1-2: Physical Memory Map 1-3

Figure 2-1: PmT1 and PmE1 Front Panel 2-1

Figure 2-2: Component Map, Top (rev. 33) 2-2

Figure 2-3: Component Map, Bottom (rev. 33) 2-3

Figure 2-4: PmT1 and PmE1 Installation 2-5

Figure 2-5: Serial Number and Product ID on Bottom Side 2-8

Figure 3-1: Processor BDM Header 3-7

Figure 6-1: TDM and FDL Connectivity Diagram 6-3

Figure 6-2: MDI Interface Protocol 6-7

Figure 6-3: Front Panel I/O Connectors, P1 and P2 6-8

Figure 6-4: Front Panel I/O Cable Assembly (C308A009-05) 6-9

Figure 7-1: PMC Interface Connectors (P11, P12, P14) 7-9

Figure 8-1: Monitor Start-up Display 8-4

10002367-02 PmT1 and PmE1 User’s Manual ix

Page 12 of the Emerson Power Module (PME1) user manual — Figures
Page 12 · click to enlarge
Page 12
Emerson Power Module (PME1) — Figures diagram (page 12)
Fig. 8 · Figures

PmT1 and PmE1 User’s Manual 10002367-02 x

(blank page)

Page 13 of the Emerson Power Module (PME1) user manual — Tables
Page 13 · click to enlarge
Page 13
Emerson Power Module (PME1) — Tables diagram (page 13)
Fig. 9 · Tables

Table 1-1: Address Summary 1-4

Table 1-2: MTBF Hours 1-4

Table 1-3: Regulatory Agency Compliance — T1 1-5

Table 1-4: Regulatory Agency Compliance — E1 1-5

Table 1-5: Technical References 1-6

Table 2-1: Circuit Board Dimensions 2-1

Table 2-2: Power Requirements 2-6

Table 2-3: Environmental Requirements 2-6

Table 3-1: MPC860P Features 3-1

Table 3-2: MPC860P Special Purpose Register Initialization 3-2

Table 3-3: MPC860P Internal Register Initialization 3-2

Table 3-4: MPC860P Exceptions 3-3

Table 3-5: MPC860P SIU Register Block Map 3-4

Table 3-6: MPC860P Ports A and C 3-6

Table 3-7: Processor BDM Pin Assignments 3-7

Table 4-1: I2C EEPROM Registers 4-1

Table 4-2: I2C EEPROM Memory Map 4-2

Table 4-3: RAM Acess Time 4-3

Table 5-1: MPC860P CPM Register Block Map 5-1

Table 5-2: CPM Initialization Values 5-2

Table 5-3: RISC Controller Processing Priority 5-2

Table 5-4: Asynchronous Baud Rates (16X oversample) 5-6

Table 5-5: Synchronous Baud Rates 5-7

Table 5-6: P14, P0, P2 Pin Assignments 5-7

Table 6-1: TDM to T1E1 Port Connections for TDMB (P1) 6-1

Table 6-2: T1E1 Signals from Transceiver, P1 6-2

Table 6-3: TDM to T1E1 Port Connections for TDMA (P2) 6-2

Table 6-4: T1E1 Signals from Transceiver, P2 6-2

Table 6-5: FDL QUICC Port Assignments 6-6

Table 6-6: MDI Port Connections 6-7

Table 6-7: MDI Bit Field Format 6-8

Table 6-8: Compu-Shield to RJ45 Pin Assignments 6-9

Table 7-1: PCI Configuration Registers 7-1

Table 7-2: Local Configuration Registers 7-2

Table 7-3: Shared Runtime Registers 7-3

Table 7-4: PCI9060ES PCI Configuration Register Initialization 7-4

Table 7-5: PCI9060ES Local Configuration Register Initialization 7-5

Table 7-6: PCI9060ES Shared Runtime Register Initialization 7-6

Table 7-7: PCI9060ES Bus Priority Control 7-7

Table 7-8: PCI-to-Local Slave Access Timing 7-8

10002367-02 PmT1 and PmE1 User’s Manual xi

Page 14 of the Emerson Power Module (PME1) user manual — Tables
Page 14 · click to enlarge
Page 14
Emerson Power Module (PME1) — Tables diagram (page 14)
Fig. 10 · Tables

Table 7-9: Connector P11 and P12 Pin Assignments 7-9

Table 8-1: NVRAM Configuration Groups 8-2

Table 8-2: Device Download Format 8-9

Table 8-3: NVRAM Power-up Diagnostic PASS/FAIL Flags 8-17

Table 8-4: PLX Mailbox 0 Sequence and Fail Mask Bits 8-17

Table 8-5: Error and Screen Messages 8-28

Table 8-6: Assigned Exception Vectors 8-34

Table 8-7: IsLegal Function Types 8-39

Table 8-8: NVOp Command 8-41

Table 8-9: NVOP Error Codes 8-42

PmT1 and PmE1 User’s Manual 10002367-02 xii

Page 15 of the Emerson Power Module (PME1) user manual — Registers
Page 15 · click to enlarge
Page 15
Emerson Power Module (PME1) — Registers diagram (page 15)
Fig. 11 · Registers

Register 4-1: Board Configuration 0 (BCR), 0x010 4-3

10002367-02 PmT1 and PmE1 User’s Manual i

Page 16 of the Emerson Power Module (PME1) user manual — Registers
Page 16 · click to enlarge
Page 16
Emerson Power Module (PME1) — Registers diagram (page 16)
Fig. 12 · Registers

PmT1 and PmE1 User’s Manual 10002367-02 ii

(blank page)

Page 17 of the Emerson Power Module (PME1) user manual — FUNCTIONAL OVERVIEW
Page 17 · click to enlarge
Page 17
Emerson Power Module (PME1) — Overview diagram (page 17)
Fig. 13 · Overview

The PmT1 and PmE1 is a single width PMC module designed to provide high-speed T1 and E1 interfaces for PMC-compatible baseboards. The design is based on the Freescale™ MPC860P PowerQUICC™ microprocessor and the PLX Technology PCI9060ES bus interface controller. The PmT1 has two standard landed T1 channels, and the PmE1 has two standard landed E1 channels. An optional EIA-422 port is available.

COMPONENTS AND FEATURES

The following is a brief summary of the PmT1 and PmE1 hardware components and fea- tures:

CPUThe CPU for the PmT1 and PmE1 is the Freescale MPC860P PowerQUICC 32-bit micropro-

cessor chip running at 80MHz. See Chapter 3 for processor features.

RAM: The PmT1 and PmE1 module is populated with 16 megabytes of 32-bit wide DRAM.

Flash: The PmT1 and PmE1 module has a 32-pin PLCC flash socket with a 512-kilobyte flash capac-

ity.

Serial I/O: The PmT1 and PmE1 module has two EIA-232 I/O ports implemented with two serial man-

agement controllers (SMCs). If the second E1 channel is not required, the PmE1 can be fac- tory configured to additionally provide a single EIA-422 serial port.

T1E1The PmT1 is factory configured to support the T1 channel using the Dallas Semiconductor

DS2151Q controller. The PmE1 is factory configured to support the E1 channel using the Dallas Semiconductor DS2153Q controller.

PCI Bus: The PLX Technology PCI9060ES controls the Peripheral Component Interconnect (PCI) bus.

The PmT1 and PmE1 modules appear as peripheral cards to PCI.

FUNCTIONAL OVERVIEW

The following block diagram provides a functional overview for the PmT1 and PmE1:

Page 18 of the Emerson Power Module (PME1) user manual — Physical Memory Map
Page 18 · click to enlarge
Page 18
Emerson Power Module (PME1) — Physical Memory Map diagram (page 18)
Fig. 14 · Physical Memory Map
Emerson Power Module (PME1) — Physical Memory Map diagram (page 18)
Fig. 15 · Physical Memory Map

!"

" "

The physical memory map of the PmT1 and PmE1 is depicted in Fig. 1-2. Information on par- ticular portions of the memory map can be found in later sections of this manual. See

Page 19 of the Emerson Power Module (PME1) user manual — Physical Memory Map
Page 19 · click to enlarge
Page 19
Emerson Power Module (PME1) — Physical Memory Map diagram (page 19)
Fig. 16 · Physical Memory Map
Emerson Power Module (PME1) — Physical Memory Map diagram (page 19)
Fig. 17 · Physical Memory Map
Page 20 of the Emerson Power Module (PME1) user manual — Product Calculation Method: Hours:
Page 20 · click to enlarge
Page 20
Emerson Power Module (PME1) — Additional Information diagram (page 20)
Fig. 18 · Additional Information
Table 1-1Address Summary

Physical Address (hex):

Access Mode: Description:

See Page:

FFF0,0000 R Flash/ROM Socket 4-1

FF00,0000 R/W CPU registers 3-2

C101,0000 — reserved —

C100,0000 R/W PMC/PCI Interface registers 7-2

C000,0200 — reserved —

C000,0180 R Board Configuration register 4-3

C000,0080 — reserved —

C000,000C R Conventional Interrupt register 3-4

C000,0000 R Interrupt Vector register 3-4

8000,0000 — reserved —

6000,0000 R/W PCI I/O Space 7-2

4000,000 R/W PCI Memory Space 7-2

C101,0000 — reserved —

0000,0000 R/W DRAM 4-2

ADDITIONAL INFORMATION

This section lists the PmT1 and PmE1 hardware’s regulatory certifications and briefly dis- cusses the terminology and notation conventions used in this manual. It also lists general technical references.

Mean time between failures (MTBF) is listed in the following table:

Table 1-2MTBF Hours

Product Calculation Method: Hours:

PmT1 Bellcore Issue 5 344,234

PmE1 Telecordia Issue 1 1,333,573

Product Certification The PmT1 and PmE1 hardware has been tested to comply with various safety, immunity, and emissions requirements as specified by the Federal Communications Commission (FCC), Underwriters Laboratories (UL), and others. The following table summarizes this compliance:

Page 21 of the Emerson Power Module (PME1) user manual — Type: Specification:
Page 21 · click to enlarge
Page 21
Emerson Power Module (PME1) — Additional Information diagram (page 21)
Fig. 19 · Additional Information
Table 1-3Regulatory Agency Compliance — T1

Type: Specification:

Safety UL60950-1, CSA C22.2 No. 60950-1-03, 1st Edition – Safety of Information Technology Equipment, including Electrical Business Equipment (BI-National)

Global IEC – CB Scheme Report IEC 60950, all country deviations

Telecom FCC Part 68 – Title 47, Code of Federal Regulations, Radio Frequency Devices

IC CS03 – Radiated and Conducted Emissions, Canada

EMC FCC Part 15, Class A – Title 47, Code of Federal Regulations, Radio Frequency Devices

ICES 003, Class A – Radiated and Conducted Emissions, Canada

Table 1-4Regulatory Agency Compliance — E1

Type: Specification:

Safety IEC60950/EN60950 – Safety of Information Technology Equipment (Western Europe)

Telecom CTR012 – Business Telecommunications; Open Network Provision technical requirements; 2048 kbits/s digital unstructured leased line attachment requirements for terminal equipment.

CTR013 – Business Telecommunications Open Network Provision technical requirement, 2048 kbits/s structured, leased line attachment requirements for terminal equipment.

EMC EN55022 – Information Technology Equipment, Radio Disturbance Characteristics, Limits and Methods of Measurement

EN55024 – Information Technology Equipment, Immunity Characteristics, Limits and Methods of Measurement

ETSI EN300386 – Electromagnetic Compatibility and Radio Spectrum Matters (ERM), Telecommunication Network Equipment, Electromagnetic Compatibility (EMC) Requirements

Emerson maintains test reports that provide specific information regarding the methods and equipment used in compliance testing. Unshielded external I/O cables, loose screws, or a poorly grounded chassis may adversely affect the PmT1 and PmE1 hardware’s ability to comply with any of the stated specifications.

The UL web site at ul.com has a list of Emerson’s UL certifications. To find the list, search in the online certifications directory using Emerson’s UL file number, E190079. There is a list for products distributed in the United States, as well as a list for products shipped to Can- ada. To find the PmT1 and PmE1, search in the list for 01439143-xx, where xx changes with each revision of the printed circuit board.

Page 22 of the Emerson Power Module (PME1) user manual — Device / Interface: Document: 1
Page 22 · click to enlarge
Page 22
Emerson Power Module (PME1) — RoHS Compliance diagram (page 22)
Fig. 20 · RoHS Compliance

RoHS Compliance The PmT1 and PmE1 are compliant with the European Union’s RoHS (Restriction of Use of Hazardous Substances) directive created to limit harm to the environment and human health by restricting the use of harmful substances in electrical and electronic equipment. Effective July 1, 2006, RoHS restricts the use of six substances: cadmium (Cd), mercury (Hg), hexavalent chromium (Cr (VI)), polybrominated biphenyls (PBBs), polybrominated diphenyl ethers (PBDEs) and lead (Pb). Configurations that are 5-of-6 are built with tin-lead solder per the lead-in-solder RoHS exemption.

To obtain a certificate of conformity (CoC) for the PmT1 and PmE1 modules, send an e-mail to sales@artesyncp.com or call 1-800-356-9602. Have the part number(s) (e.g., C000####-##) for your configuration(s) available when contacting Emerson.

Terminology and Notation

Active low signals: An active low signal is indicated with an asterisk * after the signal name.

Byte, word: Throughout this manual byte refers to 8 bits, word refers to 16 bits, and long word refers to

32 bits, double long word refers to 64 bits.

PLD: This manual uses the acronym, PLD, as a generic term for programmable logic device (also

known as FPGA, CPLD, EPLD, etc.).

Radix 2 and 16Hexadecimal numbers end with a subscript 16 . Binary numbers are shown with a

subscript 2.

Technical References Further information on basic operation and programming of the PmT1 and PmE1 compo- nents can be found in the following documents:

Table 1-5Technical References

Device / Interface: Document: 1

Controller, T1/E1 DS2153Q, E1 Single Chip Transceiver Data Sheet (Dallas Semiconductor, REV: 01106)

DS2151Q, T1 Single Chip Transceiver Data Sheet (Dallas Semiconductor, REV: 011706)

Application Note 342; DS2151, DS2153 Initialization and Programming (Dallas Semiconductor, 102899) http://www.maxim-ic.com/

CPU MPC860P PowerQUICC™ Technical Summary (Freescale Semiconductor, 07/2004 Rev. 3) http://www.freescale.com/

Page 23 of the Emerson Power Module (PME1) user manual — Device / Interface: Document: 1 (continued)
Page 23 · click to enlarge
Page 23
Emerson Power Module (PME1) — RoHS Compliance diagram (page 23)
Fig. 21 · RoHS Compliance

Device / Interface: Document: 1 (continued)

EEPROM CAT93C86 (Die Rev. C) 16-Bit Microwire Serial EEPROM (Catalyst l Semiconductor, Inc.., Doc. No. 1091, Rev. O, 10/13/06) http://www.catsemi.com/

PCI PCI Local Bus Specification (PCI Special Interest Group, Revision 2.1 1995) http://www.pcisig.com/

PCI9060ES PCI Bus Master Interface Chip for Adapters and Embedded Systems–data sheet (Mountain View, CA: PLX Technology, Inc., December1995 VERSION 1.2) http://www.plxtech.com/

PMC Draft Standard for a Common Mezzanine Card Family: CMC P1386/Draft 2.0 April 4, 1995 (IEEE:New York, NY)

Draft Standard Physical and Environmental Layers for PCI Mezzanine Cards: PMC P1386.1/Draft 2.0 April 4, 1995 (IEEE: New York, NY) http://www.ieee.org/

Serial Interface EIA Subcommittee TR-30.2 on Interface, EIA Standard RS-232-D (Electronic Industries Association, August 1969) http://www.eia.org/

1. Frequently, the most current information regarding addenda/errata for specific documents may be found on the corresponding web site.
Page 24 of the Emerson Power Module (PME1) user manual — RoHS Compliance
Page 24 · click to enlarge
Page 24
Emerson Power Module (PME1) — RoHS Compliance diagram (page 24)
Fig. 22 · RoHS Compliance
Emerson Power Module (PME1) — RoHS Compliance diagram (page 24)
Fig. 23 · RoHS Compliance
Page 25 of the Emerson Power Module (PME1) user manual — Width: Depth: Height:
Page 25 · click to enlarge
Page 25
Emerson Power Module (PME1) — Setup diagram (page 25)
Fig. 24 · Setup

This chapter describes the physical layout of the boards, the setup process, and how to check for proper operation once the boards have been installed. This chapter also includes troubleshooting, service, and warranty information.

ELECTROSTATIC DISCHARGE

Before you begin the setup process, please remember that electrostatic discharge (ESD) can easily damage the components on the PmT1 and PmE1 hardware. Electronic devices, espe- cially those with programmable parts, are susceptible to ESD, which can result in opera- tional failure. Unless you ground yourself properly, static charges can accumulate in your body and cause ESD damage when you touch the board.

necessary. Always wear a wriststrap to ground your body before touching a board. Keep your body grounded while handling the board. Hold the board by its edges–do not touch any components or circuits. When the board is not in an enclosure, store it in a static- shielding bag.

To ground yourself, wear a grounding wriststrap. Simply placing the board on top of a static- shielding bag does not provide any protection–place it on a grounded dissipative mat. Do not place the board on metal or other conductive surfaces.

PMT1 AND PME1 CIRCUIT BOARD

The PmT1 and PmE1 circuit board is a PMC module assembly. It uses an eight-layer printed circuit board with the following dimensions:

Table 2-1Circuit Board Dimensions

Width: Depth: Height:

5.86 in. (148.8 mm) 2.913 in. (74.0 mm) .39 in. (10.0 mm)

The following figures show the front panel and component maps for the PmT1 and PmE1 circuit board.

Figure 2-1PmT1 and PmE1 Front Panel
Emerson Power Module (PME1) — Width: Depth: Height: diagram (page 25)
Fig. 25 · Width: Depth: Height:

!

Page 26 of the Emerson Power Module (PME1) user manual — Setup
Page 26 · click to enlarge
Page 26
Emerson Power Module (PME1) — Setup diagram (page 26)
Fig. 26 · Setup
Page 27 of the Emerson Power Module (PME1) user manual — Setup
Page 27 · click to enlarge
Page 27
Emerson Power Module (PME1) — Setup diagram (page 27)
Fig. 27 · Setup
Page 28 of the Emerson Power Module (PME1) user manual — INSTALLATION
Page 28 · click to enlarge
Page 28
Emerson Power Module (PME1) — Connectors diagram (page 28)
Fig. 28 · Connectors

Connectors The PmT1 and PmE1 circuit board has various connectors (see the figures beginning on page 2-2), summarized as follows:

P1/P2These connectors are installed for the PmT1 front panel I/O configurations. See Chapter 6

for pin assignments.

P3: This is the optional 10-pin BDM JTAG header for viewing processor functions. See Table 3-7

for pin assignments.

P11/P12These provide a 32-bit PCI interface between the module and the PMC baseboard. Pin

assignments are shown in Chapter 7.

P14: This is the I/O connector for the EIA-422 and EIA-232 serial ports. See Chapter 5 for pin

assignments.

INSTALLATION

The PmT1 and PmE1 module may be installed in either expansion site on the baseboard. To attach the module to your baseboard, follow these steps:

1 Remove the loosely installed screws from the standoffs on the PmT1 and PmE1 module.

2 Line up the P11, P12, and P14 connectors and the 5V keying hole with the PMC connectors and the keying pin on the baseboard. Press the module into place, making sure that the connectors are firmly mated and the module front panel is fully seated in the baseboard front panel.

3 From the back of the baseboard, insert and tighten the two screws in the standoffs closest to the PMC connectors.

Page 29 of the Emerson Power Module (PME1) user manual — PmT1 and PmE1 Setup
Page 29 · click to enlarge
Page 29
Emerson Power Module (PME1) — PmT1 and PmE1 Setup diagram (page 29)
Fig. 29 · PmT1 and PmE1 Setup
Emerson Power Module (PME1) — PmT1 and PmE1 Setup diagram (page 29)
Fig. 30 · PmT1 and PmE1 Setup

You need the following items to set up and check the operation of the Emerson PmT1 and PmE1:

❐Serial interface cable for EIA-232 port, Emerson part #C0006322-xx0

❐Two Compu-shield to RJ45 cable assemblies (Emerson part number C308A009-xx) for

Save the antistatic bag and box for future shipping or storage.

Power Requirements The Emerson PmT1 and PmE1 circuit board typically requires 6.7 watts maximum.

Page 30 of the Emerson Power Module (PME1) user manual — TROUBLESHOOTING
Page 30 · click to enlarge
Page 30
Emerson Power Module (PME1) — Environmental Considerations diagram (page 30)
Fig. 31 · Environmental Considerations
Table 2-2Power Requirements

Volts: Range (volts): Maximum Current:

+5 +/- 5% 1.16 A, typical1

1. Running on-card memory test.

The exact power requirements for the PmT1 and PmE1 circuit board depend upon the spe- cific configuration of the board, including the CPU frequency and amount of memory installed on the board. Please contact Emerson Technical Support at 1-800-327-1251 if you have specific questions regarding the board’s power requirements.

Environmental Considerations As with any printed circuit board, be sure that air flow to the board is adequate. Chassis con- straints and other factors greatly affect the air flow rate. The environmental requirements are listed in Table 2-3.

Table 2-3Environmental Requirements

Environment: Range: Relative Humidity:

Operating Temperature 0° to +55° Centigrade, ambient (at board)

Not to exceed 95% (non- condensing)

Storage Temperature —40° to 70° Centigrade Not to exceed 95% (non-condensing)

Air Flow 50 linear feet/minute n/a

RESET METHODS

The entire board is reset on power-up. A baseboard PCI reset causes a PORESET* of the PmT1 and PmE1. The PCI9060ES may be programmed to initiate a software controlled hard reset from the PCI bus.

To do a hard reset of the PmT1 and PmE1 from the local bus, clear and then set bit 16 in the PCI9060ES register at local address C100,00EC16.

To do a hard reset of the PmT1 and PmE1 from the PCI bus, the same bit must be cleared and then set in software. However, the PCI bus is little endian so this bit appears as bit 8 from the (big-endian) point of view of the MPC860P. This means that bit 8 of the register at offset 6C16 from the PCI base address must be cleared and then set. After this reset, the module must be reconfigured on PCI by the baseboard.

TROUBLESHOOTING

In case of difficulty, use this checklist:

Page 31 of the Emerson Power Module (PME1) user manual — Technical Support
Page 31 · click to enlarge
Page 31
Emerson Power Module (PME1) — Technical Support diagram (page 31)
Fig. 32 · Technical Support

❐Be sure the PmT1 and PmE1 circuit board is seated firmly in the baseboard and that the

baseboard is fully plugged in the chassis.

❐Be sure the system is not overheating.

❐Check the cables and connectors to be certain they are secure.

❐If you are using the PmT1 and PmE1 monitor, run the power-up diagnostics and check

the results. “Power-up Diagnostic/Test Commands”, Section describes the power-up diagnostics.

❐Check your power supply for proper DC voltages. If possible, use an oscilloscope to look

for excessive power supply ripple or noise (over 50 mVpp below 10 MHz).

❐Check that your terminal is connected to serial port A (SMC1).

❐The PmT1 and PmE1 monitor uses values stored in on-card NVRAM (I2C EEPROM) to

configure and set the baud rates for its console port. The lack of a prompt might be caused by incorrect terminal settings, and incorrect configuration of the NVRAM, or a malfunctioning NVRAM. Try holding down the H character during a reset to abort autoboot using NVRAM parameters. If the prompt comes up, the NVRAM console parameters are probably configured incorrectly. Enter the command nvopen, then the command nvdisplay, to check the console configuration. For more information about the way NVRAM is used to configure the console port baud rates, refer to Chapter 8.

Technical Support If you need help resolving a problem with your PmT1 and PmE1, visit http://www.emersonembeddedcomputing.com/contact/postsalessupport.html on the Internet or send e-mail to support@artesyncp.com. If you do not have internet access, call Emerson for further assistance:

(800) 327-1251 or (608) 826-8006 (US) 44-131-475-7070 (UK)

Have the following information available when contacting support:

  • PmT1 and PmE1 serial number and product identification (see Fig. 2-5 )
  • monitor version (see Fig. 8-1 start-up display)
  • the baseboard serial number and product identification
  • version and part number of the operating system (if applicable) This information is labeled on the master media supplied by Emerson or another vendor.
  • whether your board has been customized for options such as a higher processor speed or additional memory
Page 32 of the Emerson Power Module (PME1) user manual — RMA #____________
Page 32 · click to enlarge
Page 32
Emerson Power Module (PME1) — Product Repair diagram (page 32)
Fig. 33 · Product Repair
  • license agreements (if applicable)
Figure 2-5Serial Number and Product ID on Bottom Side

Product Repair If you plan to return the board to Emerson Network Power for service, visit http://www.emersonembeddedcomputing.com/contact/productrepair.html on the inter- net or send e-mail to serviceinfo@artesyncp.com to obtain a Return Merchandise Authori- zation (RMA) number. We will ask you to list which items you are returning and the board serial number, plus your purchase order number and billing information if your PmT1 and PmE1 hardware is out of warranty. Contact our Test and Repair Services Department for any warranty questions. If you return the board, be sure to enclose it in an antistatic bag, such as the one in which it was originally shipped. Send it prepaid to:

Emerson Network Power, Embedded Computing Test and Repair Services Department 8310 Excelsior Drive Madison, WI 53717

RMA #

Please put the RMA number on the outside of the package so we can handle your problem efficiently. Our service department cannot accept material received without an RMA num- ber.

Show 6 more labels / short text on this page
· · · · ·
Page 33 of the Emerson Power Module (PME1) user manual — MPC860P INITIALIZATION
Page 33 · click to enlarge
Page 33
Emerson Power Module (PME1) — Central Processing Unit diagram (page 33)
Fig. 34 · Central Processing Unit

The PmT1 and PmE1 module uses the Freescale MPC860P PowerQUICC™ microprocessor installed as its CPU. The MPC860P combines an embedded PowerPC™ core with features of the QUICC MC68360 communications processor module (CPM). This chapter is an overview of the processor logic on the PmT1 and PmE1. It includes information on the CPU, excep- tion handling, and processor reset.

Table 3-1MPC860P Features
Emerson Power Module (PME1) — Central Processing Unit diagram (page 33)
Fig. 35 · Central Processing Unit

MMU 32-entr y instruction and data Translation Look-aside Buffer (TLB)

ATM 10/100 base-T Ethernet, QMC microcode for multichannel HDLC support

Serial Channel four SCCs, two SMCs, one SPI and on I2C interface

Memory controller, internal and external bus interface units, real-time clock, PCMIA-ATA interface, and JTAG TAP

Beyond the usual CPU functions, the MPC860P provides:

  • A DRAM controller is contained in the system interface unit (SIU). The memory controller is described in the “On-card DRAM”, Section .
  • Four high-speed SCC serial ports are supported by the CPM. The serial interface is described in Chapter 5

MPC860P INITIALIZATION

Some of the MPC860P registers must be initialized with Emerson-specific values. The val- ues in the following tables assume a PmT1 and PmE1 configuration of 9600 baud, 40-MHz and CPU speed.

The relevant special purpose registers on the MPC860P are accessed with the Move to Spe- cial Registers (mtspr) and the Move from Special Registers (mfspr) instructions.

Page 34 of the Emerson Power Module (PME1) user manual — Central Processing Unit
Page 34 · click to enlarge
Page 34
Emerson Power Module (PME1) — Central Processing Unit diagram (page 34)
Fig. 36 · Central Processing Unit
Emerson Power Module (PME1) — Central Processing Unit diagram (page 34)
Fig. 37 · Central Processing Unit

638 IMMR FF00,0000 Internal memory map sets up the base address of the MPC860P internal register block

The internal registers of the MPC860P are mapped to a contiguous 16-kilobyte block of memory space on a 64-kilobyte boundary. The special purpose register IMMR specifies the base address of this block. The following table is for the four megabyte PmT1 and PmE1, some values may change for different configurations.

Page 35 of the Emerson Power Module (PME1) user manual — MPC860P Exception Handling
Page 35 · click to enlarge
Page 35
Emerson Power Module (PME1) — MPC860P Exception Handling diagram (page 35)
Fig. 38 · MPC860P Exception Handling
Emerson Power Module (PME1) — MPC860P Exception Handling diagram (page 35)
Fig. 39 · MPC860P Exception Handling

Each type of CPU exception transfers control to a different address in the vector table. The vector table normally occupies the first 8-kilobytes of RAM (with a base address of 0000,000016) or flash (with a base address of FFF0,000016). An unassigned vector position may be used to point to an error routine or for code or data storage. Table 3-4 lists the exceptions recognized by the MPC860P in the order of their priority

Page 36 of the Emerson Power Module (PME1) user manual — Physical Hex Address: Acronym: Register Block Name:
Page 36 · click to enlarge
Page 36
Emerson Power Module (PME1) — CPU Interrupts diagram (page 36)
Fig. 40 · CPU Interrupts

Vector Address Hex Offset: Notes: (continued)

Exception:

Data TLB error 01400

Decrementer Decrementer Lowest priority

CPU Interrupts The logic on the PmT1 and PmE1 module receive external interrupts LSERR* and LINTo* from the PCI9060ES chip. These interrupts are combined on IRQ7*, which is the only exter- nal interrupt input used on the MPC860P.

The Conventional Interrupt register and the Interrupt Vector register are available to moni- tor the status of the external interrupts. These registers are byte wide and read-only. Attempts to read these registers with data sizes greater than a byte does not result in a bus error.

The Conventional Interrupt register at C000,000C16 indicates which PCI9060ES interrupts are active. If bit 5 is one, LSERR* is active. If bit 4 is one, LINTo* is active. All other bits in this register read as zero.

Bits (4:2) of the Interrupt Vector register (at C000,000016) store the vector of the highest priority external interrupt that is pending. The vector for LSERR* is 1002; the vector for LINTo* is 0112. The vector 0002 indicates that no interrupt is pending.

Internal interrupt sources including the hardware bus monitor, the software watchdog timer, the periodic interrupt timer (PIT), the real-time clock, and the CPM may each be assigned to a particular interrupt level in software. Interrupt levels may be programmed for logic low or negative edge assertion.

SYSTEM INTERFACE UNIT (SIU)

The SIU provides the MPC860P with system configuration and monitoring features. In par- ticular, two system timers are described in the following subsections. The memory control- ler is also part of the SIU but is described in the “On-card DRAM”, Section .

Table 3-5MPC860P SIU Register Block Map

Physical Hex Address: Acronym: Register Block Name:

FF00,0000 SIU General System Interface Unit

FF00,0100 MEMC Memory controller

Show 4 more labels / short text on this page
Data breakpoint 01C00 · Peripheral breakpoint 01E00 · External interrupt 00500 · FF00,0080 — reserved
Page 37 of the Emerson Power Module (PME1) user manual — MPC860 PARALLEL PORT CONFIGURATION
Page 37 · click to enlarge
Page 37
Emerson Power Module (PME1) — Timebase Counter diagram (page 37)
Fig. 41 · Timebase Counter

Physical Hex Address: Acronym: Register Block Name: (continued)

FF00,0200 — System integration timers

FF00,0280 — Clocks and reset

FF00,0300 — System integration timers keys

FF00,0380 — Clocks and reset keys

Timebase Counter This 64-bit counter provides a timebase reference for software. The counter generates a maskable interrupt when it reaches the value programmed into one of four reference regis- ters. On the PmT1 and PmE1, the timebase clock source is the system clock divided by 16.

Decrementer Counter This 32-bit counter provides a decrementer interrupt. It is clocked by the same source as the timebase counter (system clock divided by 16).

SOFTWARE RESET

The MPC860P may be reset in software via the PCI9060ES PCI interface chip. Writing a one to bit 30 at local address C100,00EC holds the local bus logic in the PCI9060ES reset and LRESETO* asserted. The contents of the PCI configuration registers and Shared Runtime registers are not reset. The PCI adapter software reset can only be cleared from the PCI bus.

To do a hard reset of the PmT1 and PmE1 from the local bus, clear and then set bit 16 in the PCI9060ES register at local address C100,00EC16.

To do a hard reset of the PmT1 and PmE1 from the PCI9060ES device, the same bit must be cleared and then set in software. However, the PCI is little endian so this bit appears as bit 8 from the (big-endian) point of view of the MPC860P. This means that bit 8 of the register at offset 6C16 from the PCI base address must be cleared and then set. After this reset, the module must be reconfigured on PCI by the baseboard.

MPC860 PARALLEL PORT CONFIGURATION

The following values set up the MPC860 parallel ports to receive RCLK from the incoming T1/E1 stream, route the clock to the respective Baud Rate Generator (TDMA: BRGO2, TDMB: BRGO4), then output the clock from the Baud Rate Generator as TCLK.

Show 4 more labels / short text on this page
padir 0x44F0 · papr 0xEFFF · pcdir 0x0002 · pcpar 0x0F00
Page 38 of the Emerson Power Module (PME1) user manual — Optional BDM Header
Page 38 · click to enlarge
Page 38
Emerson Power Module (PME1) — Optional BDM Header diagram (page 38)
Fig. 42 · Optional BDM Header

Table 3-6 lists the implementation of the MPC860 Port A and C signals used on the PmT1 and PmE1 module.

Emerson Power Module (PME1) — Optional BDM Header diagram (page 38)
Fig. 43 · Optional BDM Header

An optional 10-pin header (P3) is available for examining processor functions. The recom- mended mating connector is AMP part number 746288-1. The standard pin assignment is shown in Table 3-7.

Page 39 of the Emerson Power Module (PME1) user manual — Pin Number:
Page 39 · click to enlarge
Page 39
Emerson Power Module (PME1) — Optional BDM Header diagram (page 39)
Fig. 44 · Optional BDM Header
Figure 3-1Processor BDM Header
Table 3-7Processor BDM Pin Assignments

Pin Number:

Signal Name: Description:

1 VFLSO Visible History Buffer Flushes Status 0 output line reports how many instructions were flushed from the history buffer in the MPC860P internal core.

2 SRESET* Software Reset input signal may initiate a warm reset.

3 GND1 Ground 1

4 TCK Test Clock input scan data is latched at the rising edge of this signal (1K ohm pull-up to +5 volts, input to board, JTAG bit clock).

5 GND2 Ground 2

6 VFLS1 Visible History Buffer Flushes Status 1 output line reports how many instructions were flushed from the history buffer in the MPC860P internal core.

7 HRESET* Hardware Reset input signal is used at power-up to reset the processor.

8 TDI Test Data Input signal acts as the input port for scan instructions and data (1K ohm pull-up to +5 volts, input to board, JTAG data in).

9 3_3V +3.3 Voltage

10 TDO Test Data Output signal acts as the output port for scan (JTAG) instructions and data.

Show 4 more labels / short text on this page
· · ·
Page 40 of the Emerson Power Module (PME1) user manual — Optional BDM Header
Page 40 · click to enlarge
Page 40
Emerson Power Module (PME1) — Optional BDM Header diagram (page 40)
Fig. 45 · Optional BDM Header
Emerson Power Module (PME1) — Optional BDM Header diagram (page 40)
Fig. 46 · Optional BDM Header
Page 41 of the Emerson Power Module (PME1) user manual — I 2 C EEPROM
Page 41 · click to enlarge
Page 41
Emerson Power Module (PME1) — On-Card Memory Configuration diagram (page 41)
Fig. 47 · On-Card Memory Configuration

The PmT1 and PmE1 module provides one 32-pin flash socket, an EEPROM, and one RAM configuration. Off-card memory may be accessed via the PMC/PCI interface.

SOCKETED FLASH

The PmT1 and PmE1 modules have a 32-pin PLCC socket for a byte-wide read-only flash. Up to 512-kilobytes of flash may be installed. The socketed flash occupies physical address space FFF0,0000-FFFF,FFFF16.

The MPC860P controls the access time for flash. The default power-up timing allows flash with speeds of 200-nanoseconds or faster. We strongly suggest that you use the default timing because of the inherent risks of optimizing timing for a specific configuration, and because of the fact that flash may be cached.

not be overwritten.

I 2 C EEPROM

Another memory device on the PmT1 and PmE1 is a 16-kilobit serial EEPROM. It is internally organized as 1Kx16 and is accessed through the I2C interface pins on the MPC860P. The EEPROM supports a sixteen-byte page write mode and a self-timed write cycle. It provides a minimum endurance of 100,000 cycles and a minimum data retention of 100 years.

The I2C interface consists of the Serial Clock (SCL) and the Serial Data (SDA) lines, which are controlled by bits in the PBDIR and PBDAT registers, and accessible with longword read/write.

Table 4-1I2C EEPROM Registers
Emerson Power Module (PME1) — I 2 C EEPROM diagram (page 41)
Fig. 48

27 R/W Set SDA as an input or an output.

26 R/W I2C EEPROM Clock Line (SCL)

FF00,0AC4 PBDAT 27 W I2C EEPROM Line Driver (SDA)

FF00,0AC4 PBDAT 27 R I2C EEPROM Data on D0 (SDA)

!

Page 42 of the Emerson Power Module (PME1) user manual — ON-CARD DRAM
Page 42 · click to enlarge
Page 42
Emerson Power Module (PME1) — I2C EEPROM Operation diagram (page 42)
Fig. 49 · I2C EEPROM Operation

I2C EEPROM Operation The I2C EEPROM supports a bidirectional bus-oriented protocol. The protocol defines any device that sends data onto the bus as a transmitter and the receiving device as the receiver. The device controlling the transfer is the CPU, and the I2C EEPROM being controlled is the slave. The CPU always initiates data transfers and provides the clock for both transmit and receive operations.

Initialization software for the I2C EEPROM should issue a start condition immediately fol- lowed by a stop condition to reset EEPROM to a known state, since the chip maintains its state even between power-ups.

Emerson Memory Map The following memory map convention has been established by Emerson for data storage within the I2C EEPROM. This map allows various operating systems to store their boot parameters without affecting each other.

Table 4-2I 2 C EEPROM Memory Map

Hex Byte Offset: Description:

400—7FF User nonvolatile data storage

300—3FF Reserved for the operating system

000—2FF Reserved for the monitor

ON-CARD DRAM

The PmT1 and PmE1 support 16-megabyte DRAM configuration four bytes wide, for data storage. On-card RAM occupies physical addresses starting at 0000,000016.

The DRAM is controlled by the MPC860P DRAM controller. The controller may be pro- grammed for most memory sizes and speeds, block sizes from 32-kilobytes to 4-gigabytes, and write protection.

In addition to the basic DRAM control functions the MPC860P chip provides several addi- tional DRAM-related functions. Performance enhancing features include: programmable delay insertion for controlling RAS recovery time, RAS low time, CAS setup before RAS time, row address hold time, CAS recovery time, CAS pulse width, CAS access time, and address access time.

Page 43 of the Emerson Power Module (PME1) user manual — Cycle: Total Clocks: Wait States:
Page 43 · click to enlarge
Page 43
Emerson Power Module (PME1) — On-card Memory Sizing and Type diagram (page 43)
Fig. 50 · On-card Memory Sizing and Type

On-card Memory Sizing and Type The Board Configuration register (C000,018016) is a byte-wide, read-only register that con- tains configuration information about the MPC860P and DRAM. Bit (5) is no parity. The con- figuration registry values are factory set.

Register 4-1Board Configuration 0 (BCR), 0x010

7 6 5 4 3 2 1 0

LBS 1 0 MEMS NOB MEMS NOB

LBSLocal Bus Speed

00 Reserved 01 33.33 MHz with 66.66 MHz processor 10 40.00 MHz with 40.00 MHz processor 11 40.00 MHz with 80.00 MHz processor

Bit 4On-card memory type valued

0 Fast page mode (FPM) 1 Synchronous DRAM (not available)

MEMS/NOBMemory Size/Number of Banks

0000-0111 Reserved 1000 16/one bank of 16M x 32

DRAM Timing One of the primary functions of the MPC860P is to allow flexible control of all important DRAM timing parameters. The correct DRAM timing for any reasonable combination of board speed and DRAM speed is handled by the user-programmable machine (UPM). The timing parameters are stored in the UPM’s internal RAM. Reference Chapter 16 in the MPC860 PowerQUICC™ User’s Manual (Freescale 07/2004, Revision 3) for more details about the UPM. Table 4-3 describes the wait states for the PmT1 and PmE1 module.

Table 4-3RAM Acess Time

Cycle: Total Clocks: Wait States:

42 31

32 21

Burst Read (4 accesses)

72 3-1-2-11

Reads 41 · Writes 31 · 3-1-1-12

Page 44 of the Emerson Power Module (PME1) user manual — Cycle: Total Clocks: Wait States: (continued)
Page 44 · click to enlarge
Page 44
Emerson Power Module (PME1) — On-card Memory Sizing and Type diagram (page 44)
Fig. 51 · On-card Memory Sizing and Type

Cycle: Total Clocks: Wait States: (continued)

Burst Write (4 accesses)

52 2-1-1-11

1. At 40 MHz local bus speed.
2. At 33 MHz local bus speed.

For non-burst cycles, the number in the “Total Clocks” column of Table 4-3 is the total num- ber of CPU clock cycles required to complete the transfer, and the number in the “Wait States” column is the number of wait states per cycle.

For burst cycles, the number in the “Total Clocks” column of Table 4-3 is the total number of CPU clocks for the first access of the four long-word burst, plus the number of clocks for the second, third, and fourth cycles. The number in the “Wait States” column is the number of wait states for each of the four accesses.

2-1-1-12

Page 45 of the Emerson Power Module (PME1) user manual — THE COMMUNICATIONS PROCESSOR MODULE
Page 45 · click to enlarge
Page 45
Emerson Power Module (PME1) — Serial I/O diagram (page 45)
Fig. 52 · Serial I/O

The PmT1 and PmE1 module has six TTL serial ports that are supplied by the MPC860P Pow- erQUICC™. The MPC860P supports the serial ports with the following features:

  • Communications Processor Module (CPM), which includes a RISC controller, 224 buffer descriptors, continuous mode transmission and reception on all serial channels, dualport RAM, fourteen serial DMA (SDMA) channels, and NMSI mode (each serial channel can have its own pins)
  • Four serial communication controllers (SCCs)
  • Two serial management controllers (SMCs) for the console and download serial ports
  • Four baud rate generators that are independent (i.e., can be connected to any SCC or SMC), allow changes during operation, and have autobaud support
  • Protocols in firmware for asynchronous/synchronous UARTs, HDLC, and SS7

For detailed descriptions of the MPC860P features and examples of how to implement them, refer to the MPC860 PowerQUICC™ User’s Manual.

THE COMMUNICATIONS PROCESSOR MODULE

The physical base address of the MPC860P is FF00,000016. The following table shows the register block map for the CPM portion of the MPC860P. Please refer to the MPC860 Power- QUICC™ User’s Manual for descriptions of the registers in each register block.

Table 5-1MPC860P CPM Register Block Map
Emerson Power Module (PME1) — THE COMMUNICATIONS PROCESSOR MODULE diagram (page 45)
Fig. 53
Page 46 of the Emerson Power Module (PME1) user manual — Priority: Function: Description:
Page 46 · click to enlarge
Page 46
Emerson Power Module (PME1) — CPM Register Initialization Format diagram (page 46)
Fig. 54 · CPM Register Initialization Format

CPM Register Initialization Format Some of the CPM registers must be initialized as described in Table 5-2.

Table 5-2CPM Initialization Values

Physical Address (hex): Acronym:

Required Hex Format: Description:

FF00,0950 PADIR 000A Port A Data Direction register

FF00,0952 PAPAR 0000 Port A Pin Assignment register

FF00,0954 PAODR 0000 Port A Open Drain register

FF00,09F0 BRGC1 10144 BRG1 Configuration register

FF00,09F4 BRGC2 10144 BRG2 Configuration register

FF00,0AC2 PBODR 0010 Port B Open Drain register

FF00,0A82 SMCMR1 4823 SMC1 mode register

FF00,0A92 SMCMR2 4823 SMC2 mode register

SI

FF00,0AE0 SIMODE 1000,0000 SI Mode register

FF00,0AEC SICR 0000,0000 SI Clock route

RISC Controller The RISC controller manages the serial interface to the CPM. It services all I/O requests, allowing the CPU on the PmT1 and PmE1 module to dedicate compute time to other tasks.

The RISC controller implements user-chosen protocols, manages serial DMA transfers and independent DMA transfers (optionally), and maintains 16 timers for use in application soft- ware. See Table 5-3 for the RISC controller processing priority. It can communicate with the external processor using the following methods:

  • Parameters exchanged through dual-port RAM
  • External processor executes special commands via the RISC controller
  • RISC controller generates interrupts through the interrupt controller

External processor reads the controller's status/event registers

Table 5-3RISC Controller Processing Priority

Priority: Function: Description:

Highest 1 Reset in RISC Processor Command register or System Reset

2 SDMA Bus Error

3 Commands issued in the RISC Processor Command register

Input/Output Port · BRGs · SMCs

Page 47 of the Emerson Power Module (PME1) user manual — Priority: Function: Description:
Page 47 · click to enlarge
Page 47
Emerson Power Module (PME1) — CPM Interrupt Handling diagram (page 47)
Fig. 55 · CPM Interrupt Handling

Priority: Function: Description:

Lowest 19 RISC Timers

CPM Interrupt Handling The CPM RISC controller generates interrupts through the interrupt controller to the CPU. The interrupt vector is provided by the CPU.

The interrupt controller is the focal point for all internal and external interrupt requests by the CPM. It handles up to 28 interrupt sources (12 external, 16 internal) which may be assigned to a programmable interrupt level (1, 3, 5, 7). The priority in which interrupt sources are serviced is generally fixed (see the MPC860 PowerQUICC™ User’s Manual), but some flexibility is provided to modify the priority structure, particularly with respect to the SCCs.

Dual-Port RAM The CPM has 8KB of SRAM configured as dual-port memory. It can be accessed by the RISC processor, the CPU, IDMAs, and SDMAs. The dual-port RAM has the following uses–any two of which can occur simultaneously:

  • Store parameters associated with the SCCs and IDMAs
  • Store buffer descriptors (describe the location of data buffers)
  • Store data from the serial channels
  • Store RAM microcode for the RISC processor
  • Scratchpad RAM space for the user program
Show 15 more labels / short text on this page
4 SCC1 Reception · 5 SCC1 Transmission · 6 SCC2 Reception · 7 SCC2 Transmission · 8 SCC3 Reception · 9 SCC3 Transmission · 10 SCC4 Reception · 11 SCC4 Transmission · 12 SMC1 Reception · 13 SMC1 Transmission · 14 SMC2 Reception · 15 SMC2 Transmission · 16 reserved · 17 reserved · 18 reserved
Page 48 of the Emerson Power Module (PME1) user manual — MPC860P SERIAL INTERFACE
Page 48 · click to enlarge
Page 48
Emerson Power Module (PME1) — General Purpose Timers diagram (page 48)
Fig. 56 · General Purpose Timers

General Purpose Timers The general purpose timers can be configured as four 16-bit or two 32-bit identical timers. The best resolution of the time is one clock cycle, which translates to 25 nanoseconds at 40 MHz. The maximum period is 268,435,456 cycles, translating to 6.7 seconds at 40 MHz.

Independent DMA (IDMA) Channels The MPC860P has two IDMA channels which may be programmed by the user to transfer data between any combination of memory and I/O. The IDMA supports 32-bit data and addressing, dual or single address modes, and three buffer modes (single, auto, and buffer chaining). The theoretical maximum data rate of the IDMA with a local bus speed of 25 MHz is 50 MB/second.

Serial DMA (SDMA) Channels The MPC860P has fourteen SDMA channels dedicated to the transmit/receive channels of the serial controllers. Data from the serial controllers may be routed either to external RAM or to internal dual-port RAM. When transfers use the internal dual-port RAM, other opera- tions may occur simultaneously on the PmT1 and PmE1 local bus.

MPC860P SERIAL INTERFACE

Several types of popular serial protocols are available on the PmT1 and PmE1. Please refer to the MPC860 PowerQUICC™ User's Manual for more detail on these supported protocols.

UARTThe universal asynchronous receiver transmitter protocol is the defacto standard for com-

municating low-speed data between equipment. The most popular of these is the EIA-232 standard. EIA-232 specifies standard baud rates, handshaking protocols, and mechani- cal/electrical details. Other popular standards include EIA-422 and EIA-485, which offer fea- tures such as longer line lengths and multidrop support.

The UART also supports synchronous mode, where a clock is provided with each bit. Syn- chronous UART mode can provide faster data transfers, because there is no need to over- sample the data bits.

HDLC: HDLC is one of the most common layer 2 protocols (of the seven-layer OSI model). HDLC

protocol consists of a framing structure which is synchronously transferred. Therefore, HDLC relies on the physical layer (i.e., SI with TSA) to provide a method of clocking and syn- chronizing the transmitter/receiver. Each of the four SCCs can function as an HDLC control- ler. The SCC outputs can then be routed directly to the external pins, or connected to one of two TDM channels via the TSA.

Page 49 of the Emerson Power Module (PME1) user manual — Serial Communication Controllers (SCC)
Page 49 · click to enlarge
Page 49
Emerson Power Module (PME1) — Serial Communication Controllers (SCC) diagram (page 49)
Fig. 57 · Serial Communication Controllers (SCC)

Serial Communication Controllers (SCC) The MPC860P has four SCCs which may be configured independently to implement differ- ent protocols. Protocols such as UART, HDLC, and SS7 are supported to varying degrees in the MPC860P.

The choice of protocol is independent of the choice of physical interface. The SCCs do not implement the physical interface. They are connected to the outside world via the serial interface (SI). The SI can route the SCC/SMC outputs directly to the MPC860P external pins, or it can multiplex any combination of SCCs and SMCs together on one or two TDM chan- nels using the time slot assigner.

Each of the internal clocks (RCLK, TCLK) for each SCC can be driven by one of four baud rate generators or one of four external clock pins. These clocks have a top rate of one half of the system clock (20 MHz at 40 MHz).

Serial Management Controllers (SMC) The MPC860P contains two SMCs configured as UART ports. SMC1 is assigned as the DCE console port A, and SMC2 is assigned as the DCE download port B. The SMC physical inter- face is implemented via the serial interface and time slot assigner, and may also be con- nected to a TDM channel. The clock is driven by either one of four baud rate generators or from an external clock pin.

Time Slot Assigner (TSA) The TSA allows any combination of SCCs and SMCs to multiplex their data together on either one or two time-division multiplexed (TDM) channels. A TDM is defined as a serial channel which is divided into channels separated by time. Common examples of TDM chan- nels are T1/E1, CEPT, PCM Highway, ISDN Primary Rate, and ISDN Basic Rate (IDL and GCI). You may define your own interface as well.

The serial interface with TSA implements both the internal route selection and, if necessary, time division multiplexing for multiplexed serial channels. The TSA is completely indepen- dent of the protocol used by the SCCs and SMCs. The purpose of the TSA is to route data from the specified pins to the desired SCC or SMC at the correct time. The SCCs and SMCs then handle the data they receive.

The TSA also supports:

  • 1 or 2 clocks per data bit
  • programmable delay (0-3 bits) between frame sync and frame start
  • four programmable strobe outputs
  • two clock output pins
Page 50 of the Emerson Power Module (PME1) user manual — System Frequency=40 MHz Baud Rate:
Page 50 · click to enlarge
Page 50
Emerson Power Module (PME1) — UART Baud Rate Selection diagram (page 50)
Fig. 58 · UART Baud Rate Selection
  • frames up to 8-kilobits long

UART BAUD RATE SELECTION

The clock sources for each SCC are defined in the SICR register (FF00,0AEC16) and for each SMC are defined in the SIMODE register (FF00,0AE016). Any one of four internal baud rate generators or an external clock may be used.

The internal baud rate generators are contained in the CPM. They can deliver a maximum baud rate at one half of the system clock rate and may be changed on-the-fly. Each baud rate generator may be routed to multiple SCCs and SMCs.

The baud rate produced by a generator is set within the corresponding Baud Rate Generator Control (BRGC) register (FF00,09F0 - 9FC16). The baud rate is calculated from the system frequency (40 MHz) and the values stored in the BRGC register, and depends on whether the serial controller is operating in asynchronous or synchronous mode.

The formula for the asynchronous baud rate is:

async baud rate = (system frequency) ÷ ((clock divider +1) x (Div16) x 16)

The clock divider value is stored in bits (12:1) of the BRGC. The Div16 value (1 or 16) is selected with bit 0 of the BRGC. Table 5-4 lists the clock divider and Div16 values associated with typical asynchronous baud rates.

Table 5-4Asynchronous Baud Rates (16X oversample)

System Frequency=40 MHz Baud Rate:

Div16 Value: Clock Divider + 1: Actual Frequency:

Frequency Error (%):

50 16 3125 50 0.0

75 16 2083 75 0.0

150 16 1041 150.1 0.0

300 16 521 299.9 0.0

600 1 4167 599.95 0.0

1200 1 2083 1200.2 0.0

2400 1 1042 2399.2 0.0

4800 1 521 4798.5 0.0

9600 1 260 9615.4 0.2

19200 1 130 19230.8 0.2

38400 1 65 38461.5 0.2

57600 1 43 58139.5 0.9

64000 1 39 64102.6 0.2

115200 1 22 113636.4 1.4

56000 1 45 55555.6 0.8

Page 51 of the Emerson Power Module (PME1) user manual — System Frequency=40 MHz Baud Rate (Kbaud):
Page 51 · click to enlarge
Page 51
Emerson Power Module (PME1) — Serial Connector Pin Assignments diagram (page 51)
Fig. 59 · Serial Connector Pin Assignments

System Frequency=40 MHz (continued) Baud Rate:

Div16 Value: Clock Divider + 1: Actual Frequency:

Frequency Error (%):

76800 1 33 75757.6 1.4

The formula for the synchronous baud rate is:

sync baud rate = (system frequency) ÷ ((clock divider +1) x (Div16))

The clock divider value is stored in bits (12:1) of the BRGC. The Div16 value (1 or 16) is selected with bit 0 of the BRGC. Table 5-5 lists the clock divider and Div16 values associated with typical synchronous baud rates.

Table 5-5Synchronous Baud Rates

System Frequency=40 MHz Baud Rate (Kbaud):

Div16 Value: Clock Divider + 1: Actual Frequency:

Frequency Error (%):

1544 (T1) 1 26 1538.5 0.4

2048 (E1) 1 20 2000 2.3

SERIAL CONNECTOR PIN ASSIGNMENTS

The PmT1 and PmE1 module has a 64-pin connector for the serial I/O interface. The P14 pin assignments, including the VME P0 and VME P2 pin numbers specific to Emerson base- boards are shown in Table 5-6.

Reference “PMC Connector Pin Assignments” Section for the remaining PMC connectors, P11 and P12; and “Front Panel I/O” Section for the front panel I/O connectors, P1 and P2.

Table 5-6P14, P0, P2 Pin Assignments
P14 PinP0 Pin: P2 Pin: Signal: P14 Pin: P0 Pin: P2 Pin: Signal:

1 E4 C1 Console RxData 2 — — —

3 C4 C2 Console TxData 4 — — —

5 — — — 6 — — —

7 D5 C4 GND 8 C5 A4 Download RxData

9 — — — 10 A5 A5 Download TxData

11 — — — 12 — — —

Page 52 of the Emerson Power Module (PME1) user manual — Serial Connector Pin Assignments
Page 52 · click to enlarge
Page 52
Emerson Power Module (PME1) — Serial Connector Pin Assignments diagram (page 52)
Fig. 60 · Serial Connector Pin Assignments
Emerson Power Module (PME1) — Serial Connector Pin Assignments diagram (page 52)
Fig. 61 · Serial Connector Pin Assignments
P14 PinP0 Pin: P2 Pin: Signal: P14 Pin: P0 Pin: P2 Pin: Signal:

15 A6 C8 TDM#2 TxTip1 16 E7 A8 TDM#2 TxRing1

17 — — — 18 C7 A9 TDM#2 RxTip1

19 B7 C10 TDM#2 RxRing1 20 A7 A10 TDM#1 TxTip1

21 E6 C11 TDM#1 TxRing1 22 — — —

23 C8 C12 TDM#1 RxTip1 24 B8 A12 TDM#1 RxRing1

25 A8 C13 RS422 TXD-* 26 E12 A13 RS422 TXD+

27 — — — 28 C12 A14 RS422 RXD+

29 B12 C15 RS422 RXD-* 30 A12 A15 RS422 RTS+

31 E13 C16 RS422 RXCLK+ 32 D13 A16 RS422 CTS+

35 A13 C18 RS422 RTS-* 36 E14 A18 GND

39 — — — 40 A14 A20 RS422 RXCLK-*

43 — — — 44 B15 A22 RS422 TXCLK-*

45 A15 C23 RS422 TXCLK+ 46 E16 A23 RS422 CTS-*

1. All xTIP and xRING signals are routed to P14 directly from the Dallas interface and do not provide circuit protection. See Regulatory Agency Warnings and Notices in preface.
Page 53 of the Emerson Power Module (PME1) user manual — TDM Interface
Page 53 · click to enlarge
Page 53
Emerson Power Module (PME1) — TDM Interface diagram (page 53)
Fig. 62 · TDM Interface

The Time Division Multiplexor (TDM) processes channelized serial data such as T1 and E1. The data channels can be routed internally to the QUICC to any of the SCC or SMC control- lers. Each port can be configured to be either T1 or E1 at manufacturing. The TDM interface consists of:

  • Three signals for the transmitter (L1TXD, L1TCLK, L1TSYNC)
  • Three for the receiver (L1RXD, L1RCLK, L1RSYNC)
  • Each direction has a data, clock and sync signal

The PmT1 supports two T1 TDM ports and the PmE1 supports two E1 TDM ports. The TDM signals are converted to T1 or E1 signaling by either the DS2151Q or DS2153Q transceivers and are routed to the front panel connectors (P1 and P2). Table 6-1 and Table 6-3 indicate which QUICC pins are dedicated to the TDM, and how the T1 or E1 signals from the trans- ceiver are routed to the connectors.

Configurations that route T1 or E1 out the P14 connector bypass the protection circuitry. The FCC Part 68 and UL1950 certification can be met by providing an external circuit pro- tection card.

The DS2153Q on the PmE1 requires specific initialization (reference Application Note 342; DS2151, DS2153 Initialization and Programming, Dallas Semiconductor 102899):

1 Set CCR2 to 0x04. This causes the framer to switch to RCLK if TCLK stops.

2 Wait for at least 10 ms.

3 Zero all of the framer registers except the LOTCMC bit that was set in step 1. This is important since the framer has no reset and cannot be guaranteed to be in an absolute known state after power-up.

4 Configure the desired framer settings.

5 Set the LIRST bit in CCR3

6 Clear the LIRST bit in CCR3.

Table 6-1TDM to T1E1 Port Connections for TDMB (P1)
Emerson Power Module (PME1) — TDM Interface diagram (page 53)
Fig. 63 · TDM Interface
Page 54 of the Emerson Power Module (PME1) user manual — TDM Interface
Page 54 · click to enlarge
Page 54
Emerson Power Module (PME1) — TDM Interface diagram (page 54)
Fig. 64 · TDM Interface
Emerson Power Module (PME1) — TDM Interface diagram (page 54)
Fig. 65 · TDM Interface
Table 6-3TDM to T1E1 Port Connections for TDMA (P2)

Fig. 6-1 and the signal list which follows indicate how the QUICC is connected to the DS2151Q (T1) or DS2153Q (E1) interface controller.

Page 55 of the Emerson Power Module (PME1) user manual — TDM Interface
Page 55 · click to enlarge
Page 55
Emerson Power Module (PME1) — TDM Interface diagram (page 55)
Fig. 66 · TDM Interface
Figure 6-1TDM and FDL Connectivity Diagram

The following list describes how these signals are used and how they are to be configured for the variety of options that can be supported.

RCLK: The receive clock signal is always driven by the E1 or T1 controller. The controller provides

the ability to determine if the line interface has successfully synchronized to the line inter- face.

The QUICC must always be configured to accept the receive clock on L1RCLKx. If the appli- cation requires the transmit clock TCLK to be derived from RCLK, then RCLK can be routed to an internal baud rate generator and driven as TCLK.

Show 58 more labels / short text on this page
· · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · ·
Page 56 of the Emerson Power Module (PME1) user manual — THE T1 OR E1 LINE INTERFACE
Page 56 · click to enlarge
Page 56
Emerson Power Module (PME1) — The T1 or E1 Line Interface diagram (page 56)
Fig. 67 · The T1 or E1 Line Interface

TCLK: The transmit clock must be driven to the T1 or E1 controller. The clock will be driven by a

baud rate generator. In this case, the baud rate generator is driven by the RCLK input or sys- tem clock. The TCLK line for TDM channel 'B' is routed to BRG04 to support this option.

TSYNC RSYNC: The data signals must always be driven by the T1 or E1 controller. The receive sync signal is

always an output of the T1 or E1 controller and the transmit sync must be programmed to be an output. In both cases the QUICC must be programmed to accept the sync lines on L1TSYNCx and L1RSYNCx.

Additional factory installed optional configuration resistors can be provided which connect both sync and clock lines together. This option is non-standard and is only useful when the application requires the T1 or E1 controller transmit and receive sections be multi-frame synchronized.

TSER RSER: The transmit serial data is driven by the QUICC from the L1TXDx and the receive data is

driven by the T1 or E1 controller. The QUICC must be initialized appropriately to utilize the L1TXDx and L1RXDx signals.

THE T1 OR E1 LINE INTERFACE

The PmT1 and PmE1 modules that route channels out the front panel provide protection circuitry which protects equipment from overvoltage and overcurrent stresses from light- ning strikes, power crosses and other noise impairments. This circuitry is necessary in cases where the connections are outside the customers building, and in some cases within the same building (depending on the application).

The requirements for T1 equipment are specified by FCC Part 68 (lightning), UL1950 (AC Hazards), Bell Core TR-TSY-000007 and AT&T Publication 62411. Similar requirements are specified for E1 equipment including ETS 300 046-3 and ITU K17 through K20.

The PmT1 and PmE1 modules implement the suggested secondary over-voltage protec- tion circuitry specified by Dallas Semiconductor which targets UL1459, FCC Part 68, BellCore TR-NWT-1089 and ITU K17-K20.

The DS2153Q provides the ability to shape the interface wave-form depending on the impedance and length of the line used. The PmE1 can be built to support a variety of line impedances but is normally configured to support Twisted pair, 120-Ohm line impedance. The PmT1 is configured to support Twisted pair, 100-Ohm line impedance.

Page 57 of the Emerson Power Module (PME1) user manual — THE T1 FDL INTERFACE
Page 57 · click to enlarge
Page 57
Emerson Power Module (PME1) — Configuring the T1 or E1 Interface diagram (page 57)
Fig. 68 · Configuring the T1 or E1 Interface

CONFIGURING THE T1 OR E1 INTERFACE

The PmT1 and PmE1 framers have typical configuration settings for operation. The typical operational mode for T1 is:

  • Transmit/receive ESF mode enabled
  • Line build-out set to 133 feet/0 dB (DSX-1/CSU applications)
  • B8ZS encoding enabled
  • Jitter attenuator enabled

The typical operational mode for E1 is:

  • HDB3 enabled
  • CRC4 enabled
  • CCS mode enabled (time slot 16 is available for use)
  • Automatic E-bit insertion enabled
  • Automatic resync enabled
  • Automatic remote alarm generation enabled
  • Jitter attenuator enabled
  • Line build-out set to 120 ohms
  • Si bits are otherwise managed by the framer device
  • Error counters change every 500 frames (about once per second). The error count only pertains to the second before the register was polled.

THE T1 FDL INTERFACE

The Facility Data Link (FDL) is the mechanism used by a T1 port to communicate operating statistics. The FDL consists of one bit for every other frame of data, or a 4-KHz serial data port. For most applications the FDL remains inactive waiting for commands. The DS2151Q uses the HDLC protocol to transfer information to and from the FDL.

The PmT1 support for the FDL varies depending on the application requirements. Normally the FDL can be accessed via the FDL transmit and receive registers inside the DS2151Q T1 controller. The DS2151Q can be configured to generate interrupts when the receiver goes full, transmitter goes empty, and when a particular pattern is detected at the receiver. Use the SI mode register to set up transmit and receive frame sync delays (0-3 clocks) to mask the F-bit in T1 applications (RFSDA = 1 for DS2151Q and 0 for DS2153Q).

Page 58 of the Emerson Power Module (PME1) user manual — FDL for Port P2 Pin / Function:
Page 58 · click to enlarge
Page 58
Emerson Power Module (PME1) — Configuring the T1 or E1 Interface diagram (page 58)
Fig. 69 · Configuring the T1 or E1 Interface

Depending on the configuration of the board, the FDL receiver can be connected to an SCC allowing the application to push the overhead of receive data on the QUICC chip. However, the transmitter can only be accessed via the FDL transmit register. The only exception is when the transmitter and receiver can be made multi-frame synchronized.

The T1 FDL interface consists of three signals:

1 Receive data (RXD)

2 Transmit data (TXD)

The following table indicates which QUICC pins are dedicated to the FDL.

Table 6-5FDL QUICC Port Assignments

FDL for Port P2 Pin / Function:

FDL for Port P1 Pin / Function:

PA(15) / RXD1 PA(13) / RXD1

PA(14) / TXD1 PA(12) / TXD1

PA(6) / CLK2 1

PA(4) / CLK4

1. CLK2 is derived from the receive clock (RCLK) for TDMA.

Fig. 6-1 and the following signal list indicate how the QUICC is connected to the DS2151Q (T1) or DS2153Q (E1) interface controller. The module provides factory installed optional configuration resistors to address a variety of options.

TLINK RLINK: The transmit and receive link lines are the 4-KHz serial data lines of the FDL interface. The

QUICC must be initialized appropriately to utilize the appropriate RXDx and TXDx signals.

TLCLK: There are not enough resources in the QUICC to support the transmit link clock. This means

that TLINK line does not have a clock line to frame data and FDL data can only be read using the FDL transmit register. The only exception to this case is if the transmit and receive sec- tions can be forced to be multi-frame synchronized. Then RLCLK input can be used for trans- mitter as well.

RLCLK: The receive link clock is a 4-KHz clock used to frame data on the RLINK line.

3 Clock (CLKx)

Page 59 of the Emerson Power Module (PME1) user manual — MDC
Page 59 · click to enlarge
Page 59
Emerson Power Module (PME1) — The Management Data Interface (MDI) diagram (page 59)
Fig. 70 · The Management Data Interface (MDI)

THE MANAGEMENT DATA INTERFACE (MDI)

The MDI or Management Data Interface is a 3-wire protocol which allows access to the mod- ule resources, registers and interrupts using the minimum resources necessary. This inter- face consists of Data (MDIO), Clock (MDCLK) and Interrupt (MDINT) lines.

The MDI uses control pins PC0-PC2, which are not likely to conflict with any MPC860P dedi- cated functions.

Table 6-6MDI Port Connections

Pin: Description: Port:

MDINT MDI Interrupt Request PC(15)

MDC MDI Clock PC(14)

MDIO MDI I/O Pin PC(13)

The protocol used to communicate involves sequencing bit patterns to indicate the start, command, address, data and close of a transaction. Fig. 6-2 shows how the interface is accessed. This protocol is modeled after the existing standards for serial ROM and other micro-wire type non-volatile memory devices.

Figure 6-2MDI Interface Protocol

MDC

MDIO

C A D 0 1 C C A D

Start Register Data (8 Bits) Register Address (8 Bits) Opcode (3)

The MDI interface is intended for very low bandwidth communications and/or power up configuration. The opcode specifies whether a read, write, or reset cycle is to take place. The register address and data are written to and read from the PmT1 and PmE1 modules.

The PmT1 and PmE1 MDI provides the ability to identify the module, monitor interrupts, and access the serial configuration. Table 6-7 provides the protocol format for communicat- ing with the MDI interface.

For MDI example code, contact an Emerson Network Power Technical Support representa- tive: visit http://www.emersonembeddedcomputing.com/contact/postsalessupport.html on the Internet, send e-mail to support@artesyncp.com, or call (800) 327-1251.

Page 60 of the Emerson Power Module (PME1) user manual — FRONT PANEL I/O
Page 60 · click to enlarge
Page 60
Emerson Power Module (PME1) — Front Panel I/O diagram (page 60)
Fig. 71 · Front Panel I/O
Table 6-7MDI Bit Field Format

Field: Width: Function 1 :

Start 2 The “01” transition frames the beginning of an MDI cycle.

The MDI Interface is reset when the MDIO line (which is pulled up) is high for greater than 40 clocks.

OpCode 3 0002 Reserved

0102 Module ID Register Read (returns 0216)

0112 Module Interrupt Register Read1

Bits 0—3undefined Bit 4INT1—, from DS2153/DS2151 Channel 1 Bit 5INT2—, from DS2153/DS2151 Channel 1 Bit 6INT1—, from DS2153/DS2151 Channel 0 Bit 7INT2—, from DS2153/DS2151 Channel 0

1002 DS2153/DS2151 Channel 0 (TDMA) Register Write

1012 DS2153/DS2151 Channel 1 (TDMB) Register Write

1102 DS2153/DS2151 Channel 0 (TDMA) Register Read

1112 DS2153/DS2151 Channel 1 (TDMB) Register Read

Address 8 Address of a T1 or E1 controller register (determined by 2153 or 2151 interface controller) For ID register and interrupt register cycles the address field is ignored.

Data 8 Register Read/Write Data On read cycles the MDI protocol requires that the accessing application continue to clock the interface while waiting for the MDIO line to be driven low. Once low the following 8 bits will be valid data.

1. These are read-only bits. You must enable, disable, or clear interrupts at the DS2153/DS2151 framer chip itself. The SR1 status register on each framer chip corresponds to bits 5 and 7. Similarly, the SR2 status register on each framer chip corresponds to bits 4 and 6.

FRONT PANEL I/O

Connectors P1 and P2 provide the TDM signals for the PmT1 and PmE1 front panel I/O con- figurations. The manufacturer part number for this eight-pin connector is Stewart Connec- tor Systems SS-610808-NF-P-5.

Figure 6-3Front Panel I/O Connectors, P1 and P2
Show 4 more labels / short text on this page
0012 Reserved · · ·
Page 61 of the Emerson Power Module (PME1) user manual — Front Panel I/O
Page 61 · click to enlarge
Page 61
Emerson Power Module (PME1) — Front Panel I/O diagram (page 61)
Fig. 72 · Front Panel I/O

The recommended cable assembly (Emerson part number C308A009-05) for P1 and P2 is shown in Fig. 6-4. The manufacturer part numbers for these connectors are Stewart Connec- tor Systems SS-310808-5 and SS-800810-040-250. See Table 6-8 for the Compu-Shield and RJ-45 jack pin assignments.

Emerson Power Module (PME1) — Front Panel I/O diagram (page 61)
Fig. 73 · Front Panel I/O
1. This is a straight-through cable, there is no crossover.
Page 62 of the Emerson Power Module (PME1) user manual — Front Panel I/O
Page 62 · click to enlarge
Page 62
Emerson Power Module (PME1) — Front Panel I/O diagram (page 62)
Fig. 74 · Front Panel I/O
Emerson Power Module (PME1) — Front Panel I/O diagram (page 62)
Fig. 75 · Front Panel I/O
Page 63 of the Emerson Power Module (PME1) user manual — PCI9060ES REGISTER MAP
Page 63 · click to enlarge
Page 63
Emerson Power Module (PME1) — PMC/PCI Interface diagram (page 63)
Fig. 76 · PMC/PCI Interface

The PmT1 and PmE1 module design complies with the Peripheral Component Interconnect (PCI) bus interface standard and with the associated PCI Mezzanine Card (PMC) mechanical interface standard. The PmT1 and PmE1 modules must be attached to and controlled by a PMC/PCI-compliant baseboard.

The PmT1 and PmE1 use the PLX Technology PCI9060ES interface controller to implement the +5V PMC/PCI interface. The PMC/PCI interface features:

  • Asynchronous operation between the local and PCI buses operating at up to 33.33 MHz
  • Bi-directional bus locking
  • Doorbell interrupts
  • EEPROM power-on initialization

PCI9060ES REGISTER MAP

The PCI9060ES is controlled through registers that are accessible by the MPC860P and the baseboard on which the PmT1 and PmE1 is mounted. The registers fall into four groups: PCI Configuration registers, Local Configuration registers, Shared Runtime regis- ters, and Local DMA registers. The local base address of these registers is C100,000016. The PCI base address of these registers is programmable.

The PCI9060ES registers are readable and writable in byte, word, or long-word accesses, unless noted otherwise. See page 7-3 for a description of the Emerson-specific initialization of these registers. For details on the bit fields and functionality of these registers refer to the PCI9060ES data sheet.

PCI Configuration Registers The PCI Configuration registers are also known as the “configuration header”. The configu- ration header is accessed via configuration space. The registers map baseboard local mem- ory, the Local Configuration, and Shared Runtime registers into the PCI memory map.

Table 7-1PCI Configuration Registers
Emerson Power Module (PME1) — PCI9060ES REGISTER MAP diagram (page 63)
Fig. 77
Page 64 of the Emerson Power Module (PME1) user manual — Local Bus Address (hex) :
Page 64 · click to enlarge
Page 64
Emerson Power Module (PME1) — Local Configuration Registers diagram (page 64)
Fig. 78 · Local Configuration Registers

Local Bus Address (hex) :

PCI Offset Address (hex): Size: Register Name : (continued)

C100,000C 0C Byte PCI Cache Line Size register

C100,000D 0D Byte PCI Latency Timer register

C100,000E 0E Byte PCI Header Type register

C100,000F 0F Byte PCI Built-in Self Test (BIST) register

C100,0010 10 Long PCI Base Address register (for memory access to Local Configuration and Shared Runtime registers)

C100,0014 14 Long PCI Base Address register (for I/O access to Local Configuration and Shared Runtime registers)

C100,0018 18 Long PCI Base Address register (for memory access to local address space)

C100,001C-2F 1C-2F — reserved

C100,0030 30 Long PCI Expansion ROM Base register

C100,0034-3B 34-3B — reserved

C100,003C 3C Byte PCI Interrupt Line register

C100,003D 3D Byte PCI Interrupt Pin register

C100,003E 3E Byte PCI Min_Gnt register

C100,0000 3F Word PCI Max_Lat register

Local Configuration Registers The Local Configuration registers map PCI memory and I/O into the local memory map. These registers may be accessed via local space. They may also be accessed via PCI memory and I/O space based on the values in the PCI base address registers at C100,001016 and C100,001416.

Table 7-2Local Configuration Registers

Local Bus Address (hex) :

PCI Offset Address (hex): Size: Register Name :

C100,0080 00 Long Local Address Space 0 Range register (PCI to local bus)

C100,0084 04 Long Local Space 0 Local Base Address register (PCI to local bus)

C100,0088 08 Long Local Arbitration register

C100,008C 0C Long Big/Little Endian Descriptor register

C100,0090 10 Long Local Expansion ROM Range register (PCI to local bus)

C100,0094 14 Long BREQo Control register

C100,0098 18 Long Local Bus Region Descriptor for PCI to Local Accesses register

C100,009C 1C Long Local Range register (Direct Master to PCI)

Page 65 of the Emerson Power Module (PME1) user manual — PCI9060ES INITIALIZATION
Page 65 · click to enlarge
Page 65
Emerson Power Module (PME1) — Shared Runtime Registers diagram (page 65)
Fig. 79 · Shared Runtime Registers

Local Bus Address (hex) :

PCI Offset Address (hex): Size: Register Name : (continued)

C100,00A0 20 Long Local Bus Base Address register (Direct Master to PCI memory)

C100,00A4 24 Long Local Base Address For Direct Master to PCI I/O/CFG register

C100,00A8 28 Long PCI Base Address register (Direct Master to PCI)

C100,00AC 2C Long PCI Configuration Address register (Direct Master to PCI IO/CFG)

Shared Runtime Registers The Shared Runtime registers are a collection of mailbox, interrupt, doorbell, and configura- tion registers that may be accessed from the local bus and the PCI bus.

Table 7-3Shared Runtime Registers

Local Bus Address (hex) :

PCI Offset Address (hex): : Size: Register Name :

C100,00C0 40 Long Mailbox register 0

C100,00C4 44 Long Mailbox register 1

C100,00C8 48 Long Mailbox register 2

C100,00CC 4C Long Mailbox register 3

C100,00D0-DF 50-5C — reserved

C100,00E0 60 Long PCI to Local Doorbell register

C100,00E4 64 Long Local to PCI Doorbell register

C100,00E8 68 Long Interrupt Control/Status

C100,00EC 6C Long EEPROM Control, PCI Command Codes, User I/O & Init Control register

C100,00F0 70 Long PCI Configuration ID register

PCI9060ES INITIALIZATION

The following tables describe how the PCI9060ES PCI Configuration, Local Configuration, and Shared Runtime registers are initialized to set up the PCI bridge and turn on the neces- sary functions.

The PCI bridge is used to decode portions of the local address bus and the PCI address bus. At reset, the PCI9060ES reads a serial EEPROM to initialize the PCI bridge. Five long words of data are stored in the 128-kilobyte EEPROM. These long words sequentially program the PCI Configuration registers listed in Table 7-4 and two Shared Runtime registers–Mailbox registers 0 and 1–listed in Table 7-6.

Page 66 of the Emerson Power Module (PME1) user manual — C100,0004 2
Page 66 · click to enlarge
Page 66
Emerson Power Module (PME1) — Shared Runtime Registers diagram (page 66)
Fig. 80 · Shared Runtime Registers

The serial EEPROM may be reprogrammed to configure the PCI bridge in other ways. Bits (27:24) of the PCI9060ES EEPROM control register (C100,00EC16) are used for reading and writing the EEPROM. Refer to the NS93CS46 data sheet listed in Table 1-5 for a description of the EEPROM’s programming instructions, and the PCI9060ES data sheet for the sequence in which the data is stored.

Table 7-4PCI9060ES PCI Configuration Register Initialization

Hex Value Local Bus Address (hex): Register:

at the PCI9060ES:

byte-swapped at the CPU: Notes:

C100,0000 1

PCI Configuration ID 1223 2312 This read-only register contains Emerson’s vendor ID.

C100,00021 PCI Configuration ID 0004 0400 This read-only register contains the PmT1 device ID.

C100,00021 PCI Configuration ID 0005 0500 This read-only register contains the PmE1 device ID.

C100,0004 2

PCI Command 0147 4701 Enable I/O and memory space accesses. Enable PCI9060ES to act as a bus master. Enable parity checking and the SERR* driver.

C100,00302 PCI Expansion ROM Base

00000000 00000000 Address decode enable and expansion ROM base address accesses.

C100,00081 PCI Revision ID 01 01 This read-only register contains the PmT1 and PmE1’s revision number.

C100,00091 PCI Class Code 0B20000 00200B No interface is defined.

C100,00182 PCI Base Address (for memory access to local address space)

xxxxxxxx xxxxxxxx PCI-to-local base address is 0000,000016. (PCI host sets)

C100,003C1 PCI interrupt Line 00 00 —

C100,003D1 PCI Interrupt Pin 01 01 This read-only register indicates that the PCI9060ES uses INTA* as its interrupt pin.

C100,003E1 PCI Min_Gnt 00 00 This read-only register specifies a burst period of 0 μseconds.

C100,003F1 PCI Max_Lat 00 00 This read-only register specifies a maximum latency of 0 μseconds.

1. These registers are initialized by the serial EEPROM.
2. These registers are not initialized by the serial EEPROM.
Page 67 of the Emerson Power Module (PME1) user manual — Hex Value Local Bus 1
Page 67 · click to enlarge
Page 67
Emerson Power Module (PME1) — Shared Runtime Registers diagram (page 67)
Fig. 81 · Shared Runtime Registers
Table 7-5PCI9060ES Local Configuration Register Initialization

Hex Value Local Bus 1

at the PCI9060ES:

byte-swapped at the CPU: Notes:

Address (hex):

Register:

C100,0080 Local Address Space 0 Range

FF800008 080080FF Memory space reads are prefetchable. The PCI-to-local range is set to 2MB of on-card DRAM.

C100,0084 Local Space 0 Local Base Address

00000001 01000000 PCI-to-local remap address is 0000,000016. Enable PCI-to-local accesses.

C100,0088 Local Arbitration 00400000 00004000 Enable PCI direct slave locked sequences.

C100,008C Big/Little Endian Descriptor

00000000 00000000 Little endian ordering.

C100,0090 Local Expansion ROM Range (PCI to local bus)

00000000 00000000 Disable local expansion ROM.

C100,0094 BREQo Control 00000011 11000000 Slave BREQo delay is 24 clocks. Enable local bus BREQo.

C100,0098 Local Bus Region Descriptor to PCI to Local Accesses

F8030043 430003F8 Memory space local bus width is 32 bits. There are no memory space internal wait states. Enable memory space ready input. Disable bterm input and bursting.2 The slave PCI write mode is one. Target retry delay is 120 clocks.

C100,009C Local Range (Direct Master to PCI)

E0000000 000000E0 Local-to-PCI range is 512 MB.

C100,00A0 Local Bus Base Address (Direct Master to PCI memory)

40000000 00000040 PCI memory space is mapped at 4000,000016.

C100,00A4 Local Base Address (Direct Master to PCI I/O/CFG)

60000000 00000060 PCI I/O and configuration space is mapped at 6000,000016.

C100,00A8 PCI Base Address (Remap) (Direct Master to PCI)

00000007 07000000 Local-to-PCI remap address is 0000,000016. Enable master I/O, memory accesses, and lock input.

C100,00AC PCI Configuration Address (Direct Master to PCI IO/CFG)

00000000 00000000 Local-to-PCI accesses are not converted to PCI configuration cycles.

1. These registers are initialized by the serial EEPROM.
2. Bursting on the MPC860P’s local bus must remain disabled (i.e., bit 24 of the PCI9060ES’s local register at offset 0x98 must be zero).
Page 68 of the Emerson Power Module (PME1) user manual — Assigning Priorities
Page 68 · click to enlarge
Page 68
Emerson Power Module (PME1) — Deadlocked Cycles diagram (page 68)
Fig. 82 · Deadlocked Cycles
Table 7-6PCI9060ES Shared Runtime Register Initialization

Hex Value Local Bus Address (hex): Register:

at the PCI9060ES:

byte-swapped at the CPU: Notes:

C100,00C0 Mailbox 0 00000000 00000000 These registers are initialized by the serial EEPROM. C10000C0 will be a5000000 upon successful completion of the Monitor power up diagnostics.

C100,00C4 Mailbox 1 00000000 00000000 These registers are initialized by the serial EEPROM.

Deadlocked Cycles When a local bus master attempts to access the PCI bus at the same time a PCI bus master attempts to access the local bus, a deadlocked cycle results. Neither master can complete its cycle because the other device already owns the required resource. The PCI9060ES can quickly force one of the masters to relinquish ownership of its bus and try the cycle again later. Consequently, retrying one side favors the other.

Retries on Local Direct Master Cycles

Local Direct Master cycles are transfers that originate from a local bus master and access the PCI bus. The PCI9060ES programmable Direct Slave BREQo Delay Timer and BREQo retry pin control Local Direct Master cycle retries. If enabled, this timer counts down when a Local Direct Master cycle is pending and unable to access the PCI bus. If the count expires, a true condition on the BREQo pin signals the local master to relinquish the local bus and retry its cycle later.

Retries on Direct Slave Cycles.

Direct Slave cycles are transfers that originate from a PCI bus master and access the local bus. The PCI9060ES programmable PCI Target Retry Delay Timer controls Direct Slave cycle retries. This timer counts down while a Direct Slave cycle is pending. If the count expires, the PCI9060ES signals a “target retry” condition, informing the PCI master to relinquish the PCI bus and retry its cycle later.

Assigning Priorities

When assigning a bus priority for deadlocked cycles, consider whether a series of transfers on one side of the bridge could starve access on the other side. Also, consider whether there may be other adverse effects of retrying Local Direct Master cycles or Direct Slave cycles.

The following PCI9060ES internal register fields control bus priority and also are accessible from the PmT1 and PmE1 monitor (see Table 8-1).

Page 69 of the Emerson Power Module (PME1) user manual — Hex Address: Bits: Register Field: Factory Default Value (hex):
Page 69 · click to enlarge
Page 69
Emerson Power Module (PME1) — Controlling Access Latency diagram (page 69)
Fig. 83 · Controlling Access Latency
Table 7-7PCI9060ES Bus Priority Control

Hex Address: Bits: Register Field: Factory Default Value (hex):

C100,0094 3:0 Direct Slave BREQo Delay Clocks 1 (8 clocks)

C100,0094 4 Local Bus BREQo Enable 1 (BREQo enabled)

C100,0098 31:28 PCI Target Retry Delay Clocks F (120 clocks)

As an example, a user could give priority to the Direct Slave device (PCI bus) by enabling the BREQo timer and setting Direct Slave BREQo Delay Clocks to a value less than PCI Target Retry Clocks. When a deadlock occurs, the BREQo timer expires and the PCI9060ES asserts BREQo to the local bus master, forcing it to relinquish the bus and retry its cycle later. This allows the Direct Slave cycle to complete.

Alternatively, a user could give priority to the Local Direct Master by disabling the BREQo timer and setting PCI Target Retry Clocks to a nominal value. When a deadlock occurs, the PCI target retry timer expires, forcing the Direct Slave device to relinquish the PCI bus and retry its cycle later. This allows the Local Direct Master cycle to complete.

Controlling Access Latency When initializing the PCI9060ES, make sure that the retry timers are set to a value greater than the maximum latency of the target device.

For example, if the register value for PCI Target Retry Delay Clocks is 216, a PCI master must access the local bus and complete its cycle within 16 clocks. In this situation, however, the Direct Slave cycle would seldom gain access because of the local bus acquisition latency. (The Direct Slave device must wait for the CPU to finish its local I/O cycle and relinquish the local bus.) Setting the Direct Slave BREQo Delay Clocks value too low has a similar effect on Local Direct Master cycles.

Avoiding the PCI9060ES Phantom Read As a default, Emerson configures the PCI9060ES to favor Local Direct Master cycles by allowing retries only on Direct Slave cycles (see Table 7-2). This avoids a problem with the PCI9060ES that can happen when a local bus master attempts to read from a PCI device and a deadlocked cycle occurs that results in a BREQo to the local master. The PCI9060ES retries the read cycle on the PCI bus and discards the data before the local bus master retries the cycle. This phantom read (reading ahead) by the PCI9060ES affects target devices that change their data or state upon access, such as FIFOs or other devices. (For example, some devices de-assert their interrupts after a vector is read.) In these cases, the PCI9060ES phan- tom read access can result in a bus error or bad data upon subsequent read cycles.

Page 70 of the Emerson Power Module (PME1) user manual — PMC CONNECTOR PIN ASSIGNMENTS
Page 70 · click to enlarge
Page 70
Emerson Power Module (PME1) — Managing Bandwidth diagram (page 70)
Fig. 84 · Managing Bandwidth

Managing Bandwidth It is possible to inadvertently set the PCI9060ES to give a disproportionate bandwidth on either side of the bridge. For instance, one side may retry frequently because the timer value is slightly less than the time required to gain access to the other side. As a result, the retries needlessly consume a large percentage of the attempted cycles. To avoid this situa- tion, tune the timer values appropriately for the system devices.

Bridge to Bridge Considerations Many PMC modules also incorporate a bridge chip between their PCI and local busses, essentially creating two bridges that must be crossed to complete a cycle. Often, the sec- ond bridge is a source of long delays due to the associated bus acquisition latency. The timer values should be set up to accommodate any additional latency.

PCI INTERRUPTS

The PmT1 and PmE1 has two PCI interrupt lines:

LSERR*: A synchronous level output indicating a system error. It is asserted to the MPC860P when

the PCI bus target abort or master abort status bit is set in the PCI Status Configuration reg- ister.

LINT0*A synchronous level output to the MPC860P indicating a local interrupt. The PCI-to-local

doorbell register or a PCI BIST interrupt can generate a local interrupt.

See the PCI9060ES data sheet for more details on the interrupt lines. CPU Interrupts describes the interrupt handling by the MPC860P.

PCI Bus Interface Using the DRAM timing, the PCI interface of the PmT1 and PmE1 is capable of the transfer rates given in Table 7-8. The transfer rates to PCI bus are dependent on the baseboard design. Local to PCI bus and PCI to local bus does not support bursting.

Table 7-8PCI-to-Local Slave Access Timing

Cycle Type: Wait States: Total Clocks:

Slave Read (long word) 1 5

Slave Write (long word) 1 5

PMC CONNECTOR PIN ASSIGNMENTS

The PmT1 and PmE1 modules have three 64-pin PMC connectors: P11, P12, and P14. These connectors support the PCI and serial interfaces. The pin arrangement for the 64-pin con- nector is shown in Fig. 7-1. The possible manufacturer part numbers for this connector are

Page 71 of the Emerson Power Module (PME1) user manual — Pin: P11 Signal: P12 Signal: Pin: P11 Signal: P12 Signal:
Page 71 · click to enlarge
Page 71
Emerson Power Module (PME1) — Managing Bandwidth diagram (page 71)
Fig. 85 · Managing Bandwidth

Amp 120534-1, Molex 53483-0649 or Molex 53508-0648. The recommended mating con- nectors include Amp 120521-1, Amp 120528-1, and Molex 52763-0649. Refer to Fig. 2-1 for the placement of these connectors on the PmT1 and PmE1 module.

Emerson Power Module (PME1) — Managing Bandwidth diagram (page 71)
Fig. 86 · Managing Bandwidth

The PCI interface signals are routed out P11 and P12. Pin assignments for this interface are listed in Table 7-9. The serial I/O interface is routed out P14. The pin assignments for this connector are given in Table 5-6 of the serial I/O chapter.

Pin: P11 Signal: P12 Signal: Pin: P11 Signal: P12 Signal:

5 no connect no connect 6 no connect GND

9 no connect no connect 10 no connect no connect

41 no connect no connect 42 no connect SERR*

Page 72 of the Emerson Power Module (PME1) user manual — Pin: P11 Signal: P12 Signal: Pin: P11 Signal: P12 Signal:
Page 72 · click to enlarge
Page 72
Emerson Power Module (PME1) — PCI Bus Control Signals diagram (page 72)
Fig. 87 · PCI Bus Control Signals

Pin: P11 Signal: P12 Signal: Pin: P11 Signal: P12 Signal:

51 GND AD07 52 C/BE0* no connect

53 AD06 no connect 54 AD05 no connect

55 AD04 no connect 56 GND GND

57 +5V no connect 58 AD03 no connect

59 AD02 GND 60 AD01 no connect

61 AD00 no connect 62 +5V no connect

63 GND GND 64 no connect no connect

PCI Bus Control Signals The following signals for the PCI interface are available on connectors P11 and P12. Refer to the PCI specification for detailed usage of these signals. All signals are bi-directional unless stated otherwise.

AD00-AD31: ADDRESS and DATA bus (bits 0-31) tri-state lines are used for both address and data han-

dling. A bus transaction consists of an address phase followed by one or more data phases.

BUSMODE1*-4*: The PmT1 and PmE1 modules assert BUSMODE1* to indicate to the baseboard that it is

present and capable of performing PCI protocols. The baseboard uses BUSMODE2*-4* to indicate that it is PCI compatible.

C/BE0* -C/BE3*BUS COMMAND and BYTE ENABLES tri-state lines have different functions depending on the

phase of a transaction. During the address phase of a transaction these lines define the bus command. During a data phase the lines are used as byte enables.

CLK: CLOCK input signal to the PmT1 and PmE1 provides timing for PCI transactions.

DEVSEL*DEVICE SELECT sustained tri-state signal indicates when a device on the bus has been

selected as the target of the current access.

FRAME*: CYCLE FRAME sustained tri-state line is driven by the current master to indicate the begin-

ning of an access, and continues to be asserted until transaction reaches its final data phase.

GNT*: GRANT input signal indicates that access to the bus has been granted to a particular master.

Each master has its own GNT*.

IDSELINITIALIZATION DEVICE SELECT input signal acts as a chip select during configuration read

and write transactions.

INTA*: PMC INTERRUPT A input line is used by the PmT1 and PmE1 to interrupt the baseboard.

IRDY*INITIATOR READY sustained tri-state signal indicates that the bus master is ready to com-

plete the data phase of the transaction.

Page 73 of the Emerson Power Module (PME1) user manual — PCI Bus Control Signals
Page 73 · click to enlarge
Page 73
Emerson Power Module (PME1) — PCI Bus Control Signals diagram (page 73)
Fig. 88 · PCI Bus Control Signals
LOCK*LOCK sustained tri-state signal indicates that an atomic operation may require multiple

transactions to complete.

PARPARITY is even parity across AD00-AD31 and C/BE0-C/BE3*. Parity generation is required by

all PCI agents. This tri-state signal is stable and valid one clock after the address phase, and one clock after the bus master indicates that it is ready to complete the data phase (either IRDY* or TRDY* is asserted). Once PAR is asserted, it remains valid until one clock after the completion of the current data phase.

PERR*: PARITY ERROR sustained tri-state line is used to report parity errors during all PCI transac-

tions.

REQ*: REQUEST output pin indicates to the arbiter that a particular master wants to use the bus.

RST*: RESET assertion of this input line brings PCI registers, sequencers, and signals to a consis-

tent state.

SERR*SYSTEMS ERROR open-collector output signal is used to report any system error with cata-

strophic results.

STOP*: STOP sustained tri-state signal is used by the current target to request that the bus master

stop the current transaction.

TRDY*TARGET READY sustained tri-state signal indicates the target’s ability to complete the cur-

rent data phase of the transaction.

Page 74 of the Emerson Power Module (PME1) user manual — PCI Bus Control Signals
Page 74 · click to enlarge
Page 74
Emerson Power Module (PME1) — PCI Bus Control Signals diagram (page 74)
Fig. 89 · PCI Bus Control Signals
Emerson Power Module (PME1) — PCI Bus Control Signals diagram (page 74)
Fig. 90 · PCI Bus Control Signals
Page 75 of the Emerson Power Module (PME1) user manual — POWER-UP/RESET SEQUENCE
Page 75 · click to enlarge
Page 75
Emerson Power Module (PME1) — Monitor diagram (page 75)
Fig. 91 · Monitor

The PmT1 and PmE1 monitor consists of a set of about 150 C language functions. The mon- itor commands constitute a subset of these functions and are designed to provide easy-to- use tools for PmT1 and PmE1 configurations at power-up or reset and communications, downloads, and other common uses.

This chapter includes an introduction to monitor operation, instructions for command sequences that configure the PmT1 and PmE1 modules, a command reference, and a func- tion reference.

POWER-UP/RESET SEQUENCE

At power-up or board reset, the monitor performs hardware initialization, autoboot proce- dures, free memory initialization, and if necessary, invokes the command-line editor. In more detail, monitor execution starts up as follows.

1 The MPC860P is initialized first: caches are disabled, the memory control UPM (user- programmable machine) is initialized, CS (chip select) memory map and control are initialized, and the Systems Interface Unit (SIU) is initialized.

2 The QUICC sections are initialized in the following order: the NVRAM clock and data bits, and then the console port SMC1.

3 The NVRAM is checked for functionality and valid contents (i.e., this is not the first power up). If NVRAM is not valid, power-up diagnostics are run. If NVRAM is valid, the PowerUpDiags bit is checked to see if diagnostics should be run. (Refer to Step 6 for a description of the default NVRAM configuration parameters including PowerUpDiags.) If PowerUpDiags is off, the system level initialization is performed.

4 Power-up Diagnostics: “Hello World” is printed on the console. Memory size is read from the configuration register and printed on the console. The decrementer and timebase timer is checked for functionality. The character sequence “89ABCDEF” is printed to test the print hex ASCII routine. A Write/Read test is performed at location 0x40000. 0x05050a0a and its complement is written and read. Then an address boundary test is performed.

5 System level initialization sets up the system for running compiled C code. BSS is cleared. The dynamic data section is relocated from ROM to its linked address space starting at 0x2000. The RAM-based interrupt vector table is initialized. The interrupt prefix is changed to point to the RAM-based interrupt table at 0x00000000. The stack is initialized at 0xFFF8. All interrupt vectors in the interrupt vector table are initialized to use the unexpected interrupt handler. This handler prints the message “Unexpected Interrupt” and restarts the monitor. Masking of interrupts is reinforced. The memory parameters for system memory management (e.g., Malloc) are initialized. If PowerUpDiags is set, the C code power-up tests are run. The EEPROM test is run, and if IsModConfig is set, the PCI bus is configured (see Table 8-1).

Page 76 of the Emerson Power Module (PME1) user manual — (A, B)
Page 76 · click to enlarge
Page 76
Emerson Power Module (PME1) — Monitor diagram (page 76)
Fig. 92 · Monitor

6 The countdown to autoboot begins if a boot device (BootDev) is specified. If you allow the countdown finish, the selected device is booted. Reference page 8-7 for booting from specific devices using the boot commands.

If you cancel configuration before the autoboot begins, the board is configured with the default nonvolatile configuration, which is summarized in Table 8-1. The configuration groups may be accessed with the NVRAM commands described on page 8-13.

Table 8-1NVRAM Configuration Groups

Factory Default: Optional Values:

Fields: Purpose:

Port Selects communications port. A (Console) B (Download)

(A, B)

Baud Selects baud rate. 9600

Parity Selects parity type. None (Even, Odd, None, Force)

Data Selects the number of data bits for transfer. 8-Bits (5-Bits, 6-Bits, 7-Bits, 8-Bits)

StopBits Selects the number of stop bits for transfer. 1-Bit (1-Bit, 2-Bits)

ChBaudOnBreak Break character causes baud rate change. False (True, False)

RstOnBreak Break character causes reset (Download). False (True, False)

InstrCache Turn instruction cache on or off. On (On, Off)

DataCache Turn data cache on or off. Off (On, Off)

CacheMode Select cache mode type. Writethru (Copyback, Writethru)

PowerUpMemClr Clear memory on power-up. True (True, False)

ClrMemOnReset Clear memory on reset. False (True, False)

PowerUpDiags Run diagnostics on power-up. On (On, Off)

ResetDiags Run diagnostics on reset. Off (On, Off)

Bus Monitor Turn bus monitor on or off.

CountValue Choose shortest (0) to longest (7) duration for autoboot countdown.

7 (0, 1, 2, 3, 4, 5, 6, 7)

DoModConfig Module configuration. Sets the PlxBReqTmr and PlxPciRetTmr values.

True (True, False) 1

PlxBReqTmr Select value of BReq timer in PLX register 0x94. 1 (0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15)

PlxPciRetTmr Select value of PCI target retry delay in PLX register 0x98.

15 (0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15)

BootDev Select boot device. EPROM (None, Serial, ROM, Bus, EPROM)

LoadAddress Define load address. 0x40000

Show 5 more labels / short text on this page
Console and Download · Cache · Misc · Off (On, Off) · BootParams
Page 77 of the Emerson Power Module (PME1) user manual — Monitor
Page 77 · click to enlarge
Page 77
Emerson Power Module (PME1) — Monitor diagram (page 77)
Fig. 93 · Monitor
Emerson Power Module (PME1) — Monitor diagram (page 77)
Fig. 94 · Monitor

RomBase Define ROM base. 0xfff30000 This field is used only when BootDev is defined as ROM.

RomSize Define ROM size. 0x40000 This field is used only when BootDev is defined as ROM.

DevType Define device type. 0 Whether you use this field depends on the application. When BootDev is defined as Bus or ROM, DevType refers to a device type. When BootDev is defined as Serial, DevType selects a download format (0 for hex- Intel, 1 for S-records, 2 for Emerson binary).

DevNumber Define device number. 0 Whether you use this field depends on the application.

HaltOnFailure Halt if a failure occurs. False (True, False)

1. DoModConfig must be set to False in Solaris hosts.
3. These values are entered in the Test Services department.
Page 78 of the Emerson Power Module (PME1) user manual — START-UP DISPLAY
Page 78 · click to enlarge
Page 78
Emerson Power Module (PME1) — Start-up Display diagram (page 78)
Fig. 95 · Start-up Display

START-UP DISPLAY

At power-up or after a reset, the monitor runs diagnostics and reports the results in the start-up display. The PmT1 and PmE1 displays have identical diagnostic reports.

Figure 8-1Monitor Start-up Display

! " #" $ % & " %

! "#$ %& ! '(& ! ' )*+ !$ ,,,,,,,, !- . +/ 0 1#0 23 )*+ .4 )*+ # 5!$56 5

+7# $ $ "5 8"92 : #$;222

%%%%%%%%%%% %%%%%%%%%%% %%%%%% %%%%%%%%%%%% %%%%%%%%%%%% %%%%%%%%%%%%% %%%%%%%%%%%%%%%%%%%%% %%%%%%%%%%%%%%%% %%%%%%%%%%%%%%%%% %%%%%%%%%%%%% %%%%%%%%%%%

=A1B C 0$7 $ $ "5 8 /.?98

& " "

= 2>.?98@

At power-up and reset, the monitor configures the board according to the contents of non- volatile configuration memory. If the configuration indicates that an autoboot device has been selected, the monitor attempts to load an application program from the specified device. You can prevent the board from booting the OS if any of the power-up tests fail by setting the NVRAM configuration parameter HaltOnFailure (see Table 8-1 and page 8-13).

Page 79 of the Emerson Power Module (PME1) user manual — COMMAND-LINE EDITOR
Page 79 · click to enlarge
Page 79
Emerson Power Module (PME1) — Command-line History diagram (page 79)
Fig. 96 · Command-line History

You can cancel both the nonvolatile configuration sequence and the autoboot sequence by pressing the H key on the console keyboard before the boot ends. The monitor is then in a “manual” mode from which you can execute commands and call functions. The monitor also enters manual mode if the autoboot fails. Instructions for downloading and executing remote programs are given in the command reference and function reference.

The monitor provides a command-line interface that includes a command history and a vi- like line editor. The command-line interface has two modes: insert text mode and com- mand mode. In insert text mode you can type text on the command line. In command mode you can move the cursor along the command line and modify commands. Each new line is brought up in insert text mode.

COMMAND-LINE HISTORY

The monitor maintains a history of up to 50 command lines for reuse. Press the key from the command line to access the history.

k or -: Move backward in the command history to access a previous command.

j or +: Move forward in the command history to access a subsequent command.

COMMAND-LINE EDITOR

The command-line editor uses typical UNIX® vi editing commands.

<help editor>: To access an on-line description of the editor, type help editor or h editor.

<ESC>: To exit Entry mode and start the editor, press . You can use most common vi com-

mands, such as x, i, a, A, $, w, cw, dw, r, and e.

<cr>: To execute the current command and exit the editor, press Enter or Return.

<DEL>: To discard an entire line and create a new command line, press at any time.

a or A: Append text on the command line.

i or I: Insert text on the command line.

x or X: Delete a single character.

r: Replace a single character.

w: Move the cursor to the next word.

c: Change. Use additional commands with c to change words or groups of words, as shown

below.

cw or cW: Change a word after the cursor (capital W ignores punctuation).

Page 80 of the Emerson Power Module (PME1) user manual — COMMAND SYNTAX
Page 80 · click to enlarge
Page 80
Emerson Power Module (PME1) — Initializing Memory diagram (page 80)
Fig. 97 · Initializing Memory

ce or cE: Change text to the end of a word (capital E ignores punctuation).

cb or cB: Change the word before the cursor (capital B ignores punctuation).

c$: Change text from the cursor to the end of the line.

d: Delete. Use additional commands with d to delete words or groups of words, as shown

below.

dw or dW: Delete a word after the cursor (capital W ignores punctuation).

de or dE: Delete to the end of a word (capital E ignores punctuation).

db or dB: Delete the word before the cursor (capital B ignores punctuation).

d$: Delete text from the cursor to the end of the line.

INITIALIZING MEMORY

The monitor uses the area between 0000,000016 and 0001,000016 for interrupt vector, stack, data, and bss space. Any writes to that area can cause unpredictable operation of the monitor. The monitor initializes all local memory on power-up and/or on reset, depending on the configuration of nonvolatile memory. The monitor initializes (i.e., writes to) this area, but it is left up to the programmer to initialize any other accessible memory areas, such as off-card or module memory.

COMMAND SYNTAX

Each command may be typed with the shortest number of characters that uniquely identify the command. For example, you can type nvd instead of nvdisplay. (There is no distinction between uppercase and lowercase.) Note, however, that abbreviated command names cannot be used with on-line help; you must type help and the full command name. Press Enter or Return (carriage return ) to execute a command.

  • The command line accepts three argument formats: string, numeric, and symbolic. Arguments to commands must be separated by spaces.
  • Monitor commands that expect numeric arguments assume a default base for each argument. However, the base can be altered or specified by entering a colon (:) followed by the base as in the following examples.

1234ABCD:16 hexadecimal

123456789:10 decimal

101010:2 binary

Page 81 of the Emerson Power Module (PME1) user manual — BOOT COMMANDS
Page 81 · click to enlarge
Page 81
Emerson Power Module (PME1) — Initializing Memory diagram (page 81)
Fig. 98 · Initializing Memory

INITIALIZING MEMORY

The monitor uses the area between 0000,000016 and 0001,000016 for interrupt vector, stack, data, and bss space. Any writes to that area can cause unpredictable operation of the monitor. The monitor initializes all local memory on power-up and/or on reset, depending on the configuration of nonvolatile memory. The monitor initializes (i.e., writes to) this area, but it is left up to the programmer to initialize any other accessible memory areas, such as off-card or module memory.

COMMAND SYNTAX

Each command may be typed with the shortest number of characters that uniquely identify the command. For example, you can type nvd instead of nvdisplay. (There is no distinction between uppercase and lowercase.) However, note that abbreviated command names cannot be used with on-line help; you must type help and the full command name. Press Enter or Return (carriage return ) to execute a command.

  • The command line accepts three argument formats: string, numeric, and symbolic. Arguments to commands must be separated by spaces.
  • Monitor commands that expect numeric arguments assume a default base for each argument. However, the base can be altered or specified by entering a colon (:) followed by the base. See the following examples.

Typographic Conventions In the following command descriptions, Courier font is used to show the command for- mat. Italic type indicates a field or argument that requires input.

BOOT COMMANDS

bootbus is an autoboot device that allows you to boot an application program over a bus interface. This command is used for fast downloads to reduce development time.

Definitionbootbus

bootbus uses the “LoadAddress” field from the nonvolatile memory definitions group ‘BootParams’ (see Table 8-1) as the base address of a shared memory communications structure, described below:

Example=> struct BusComStruct {

unsigned long MagicLoc;

Page 82 of the Emerson Power Module (PME1) user manual — booteprom
Page 82 · click to enlarge
Page 82
Emerson Power Module (PME1) — booteprom diagram (page 82)
Fig. 99 · booteprom

unsigned long CallAddress; };

The structure consists of two unsigned long locations. The first is used for synchronization, and the second is the entry address of the application.

The sequence of events used for loading an application is described below:

1 The host board waits for the target (this board) to write the value 0x496d4f6b (character string “ImOk”) to “MagicLoc” to show that the target is initialized and waiting for a download.

2 The host board downloads the application program over the bus, writes the application start address to “CallAddress,” and then writes 0x596f4f6b (character string “YoOk”) to “MagicLoc” to show that the application is ready for the target.

3 Target writes value 0x42796521 (character string “Bye!”) to “MagicLoc” to show that the application was found. The target then calls the application at “CallAddress.”

When the application is called, four parameters are passed to the application from the non- volatile memory boot configuration section. The parameters are seen by the application as shown below:

Application(Device, Number, RomSize, RomBase) unsigned char Device, Number; unsigned long RomSize, RomBase;

These parameters allow multiple boards using the same facility to receive configuration information from the monitor.

Also refer to the function BootUp on page 8-37.

booteprom is an autoboot device that allows you to boot an application program from EPROM.

Descriptionbooteprom

In order for the monitor to jump to the start of the program, the following conditions must be met:

  • The start of the program is at FFF4,0000 16 .
  • The first long word of the EPROM image contains a branch link instruction of the form 0100,10xx,xxxx,xxxx,xxxx,xxxx,xxxx,xx01 2 .

You can avoid jumping to an EPROM, even if a valid one is present, by changing the nonvol- atile configuration parameter BootDev to something other than EPROM. The default setting is to run an EPROM (especially if NVRAM is trashed).

Also refer to the function BootUp on page 8-37.

Page 83 of the Emerson Power Module (PME1) user manual — Device Type: Download Format:
Page 83 · click to enlarge
Page 83
Emerson Power Module (PME1) — bootrom diagram (page 83)
Fig. 100 · bootrom

bootrom is an autoboot device that allows you to boot an application program from ROM. It copies code from ROM into RAM and then jumps to the RAM address. The ROM source address RomBase, the RAM destination address LoadAddress, and the number of bytes to copy Rom- Size are read from the nonvolatile memory group BootParams.

Descriptionbootrom

When the application is called, two parameters are passed to the application from the non- volatile memory group BootParams. The parameters are seen by the application as shown below:

Application(Device, Number) unsigned char Device, Number;

There are no arguments for this command. The nonvolatile configuration is modified with the NVRAM commands nvdisplay and nvupdate.

Also refer to the function BootUp on page 8-37.

bootserial is an autoboot device that allows you to boot an application program from a serial port.

Descriptionbootserial

It determines the format of the download and the entry execution address of the down- loaded application from the LoadAddress and DevType fields in the nonvolatile memory group BootParams. The DevType field selects one of the download formats specified below:

Table 8-2Device Download Format

Device Type: Download Format:

INT_MCS86 0 Intel MCS-86 Hexadecimal Format

MOT_EXORMAT 1 Motorola Exormax Format (S0-S3,S7-S9 Records)

HK_BINARY 2 Emerson Binary Format

The nonvolatile configuration is modified with the NVRAM commands nvdisplay and nvup- date.

When the application is called, three parameters are passed to the application from the nonvolatile memory boot configuration section. The parameters are seen by the applica- tion as shown below:

Application(Number, RomSize, RomBase) unsigned char Number; unsigned long RomSize, RomBase;

These parameters allow multiple boards using the same facility to receive different configu- ration information from the monitor.

Page 84 of the Emerson Power Module (PME1) user manual — MEMORY/REGISTER COMMANDS
Page 84 · click to enlarge
Page 84
Emerson Power Module (PME1) — Help Commands diagram (page 84)
Fig. 101 · Help Commands

Also refer to the function BootUp on page 8-37.

HELP COMMANDS

help Use the help command to view the description of the monitor command specified by name. The full name of the command must be given.

Descriptionhelp name

For instructions on editing command lines, type help editor.

For a list of command-line functions, type help functions.

For a detailed memory map, type help memmap.

MEMORY/REGISTER COMMANDS

For some memory commands, the data size is determined by the following flags:

Description: The flag -b is for data in 8-bit bytes.

The flag -w is for data in 16-bit words.

The flag -l is for data in 32-bit long words.

checksummem reads bytecount bytes starting at address source and computes the checksum for that region of memory. The checksum is the 16-bit sum of the bytes in the memory block.

Descriptionchecksummem source bytecount

clearmem clears bytecount bytes starting at address source.

Descriptionclearmem source bytecount

cmpmem compares bytecount bytes at the source address with those at the destination address. Any differences are displayed.

Descriptioncmpmem source destination bytecount

copymem copies bytecount bytes from the source address to the destination address.

Page 85 of the Emerson Power Module (PME1) user manual — displaymem
Page 85 · click to enlarge
Page 85
Emerson Power Module (PME1) — displaymem diagram (page 85)
Fig. 102 · displaymem
Descriptioncopymem source destination bytecount

displaymem displays memory in 16-byte lines starting at address startaddr. The number of lines dis- played is determined by lines. If the lines argument is not specified, sixteen lines of memory are shown. The data is displayed as hex character values on the left and printable ASCII equivalents on the right. Nonprintable ASCII characters are printed as a dot.

Descriptiondisplaymem startaddr lines

Press any key to interrupt the display. If the previous command was displaymem, pressing displays the next block of memory.

fillmem fills memory with value starting at address startaddr to address endaddr.

Descriptionfillmem -[b,w,l] value startaddr endaddr

For example, to fill the second megabyte of memory with the data 0x12345678 type:

=>fill -l 12345678 100000 200000

findmem searches memory for a value from address startaddr to address endaddr for memory loca- tions specified by the data searchval.

Descriptionfindmem -[b,w,l] searchval startaddr endaddr

findnotmem searches from address startaddr to address endaddr for memory locations that are different from the data specified by searchval.

Descriptionfindnotmem -[b,w,l] searchval startaddr endaddr

findstr searches from address startaddr to address endaddr for a string matching the data string searchstr.

Descriptionfindstr searchstr startaddr endaddr

readmem reads a memory location specified by address. This command displays the data in hexadeci- mal, decimal, octal, and binary format.

Descriptionreadmem -[b,w,l] address
Page 86 of the Emerson Power Module (PME1) user manual — setmem
Page 86 · click to enlarge
Page 86
Emerson Power Module (PME1) — setmem diagram (page 86)
Fig. 103 · setmem

setmem allows memory locations to be modified starting at address. setmem first displays the value that was read. Then you can type new data for the value or leave the data unchanged by entering an empty line. If you press after the data, the address counts up. If you press after the data, the address counts down. To quit this command type any illegal hex character (for example, “.”[period]).

Descriptionsetmem -[b,w,l] address

swapmem swaps bytecount bytes at the source address with those at the destination address.

Descriptionswapmem source destination bytecount

testmem performs a nondestructive memory test from startaddr to endaddr. If endaddr is zero, the address range is obtained from the functions MemBase and MemTop. The memory test can be interrupted by pressing any character.

This command can be used to verify memory (DRAM). It prints the progress of the test and summarizes the number of passes and failures.

Descriptiontestmem startaddr endaddr

Also refer to the functions MemBase and MemTop in “Misc” Section .

um performs a destructive memory test from base_addr to top_addr. This is done by first clear- ing all memory in the range specified, doing a rotating bit test at each location, and finally filling each data location with its own address. If top_addr is zero, the address range is obtained from the functions MemBase and MemTop.

This command prints the progress of the test and summarizes the number of passes and failures. The memory test can be interrupted by pressing any character.

Descriptionum -[b,w,l] base_addr top_addr

Also refer to the functions MemBase and MemTop in “Misc” Section .

writemem writes value to a memory location specified by address.

Descriptionwritemem -[b,w,l] address value
Page 87 of the Emerson Power Module (PME1) user manual — Example:
Page 87 · click to enlarge
Page 87
Emerson Power Module (PME1) — writestr diagram (page 87)
Fig. 104 · writestr

writestr writes the ASCII string specified by string to a memory location specified by address. The string must be enclosed in double quotes (“ “).

Descriptionwritestr “string” address

NVRAM COMMANDS

The monitor uses the I2C EEPROM for nonvolatile memory. A memory map of the I2C EEPROM is given in Table 4-2 earlier in this manual. Portions of this nonvolatile memory are reserved for factory configuration and identification information and the monitor.

The nonvolatile memory support commands provide the interface to the I2C EEPROM. The nonvolatile commands deal only with the monitor- and Emerson-defined sections of the nonvolatile memory. The monitor-defined sections of nonvolatile memory are readable and writeable and can be modified by the monitor.

nvdisplay is used to display the Emerson-defined and monitor-defined nonvolatile sections. The non- volatile memory configuration information is used to completely configure the PmT1 and PmE1 modules at reset. The utility command configboard can also be used to reconfigure the board after modifications to the nonvolatile memory.

Descriptionnvdisplay

The configuration values are displayed in groups. Each group has a number of fields. Each field is displayed as a hexadecimal or decimal number, or as a list of legal values.

To display the next group, press or .

To edit fields within the displayed group, press E.

To quit the display, press or Q.

To save the changes, type the command nvupdate.

To quit without saving the changes, type the command nvopen.

Table 8-1 shows all the groups and fields you can edit when you use the nvdisplay command.

Example:

1 At the monitor prompt, type:

2 Press until the group you want to modify is displayed. An example for the group “Console” is shown below.

=>nvdisplay

Page 88 of the Emerson Power Module (PME1) user manual — nvinit
Page 88 · click to enlarge
Page 88
Emerson Power Module (PME1) — nvinit diagram (page 88)
Fig. 105 · nvinit

ParityNone(Even, Odd, None, Force)

Data8-bits(5-Bits, 6-Bits, 7-Bits, 8-Bits)

[SP, CR to continue] or [E, e to Edit]

3 Press E to edit the group.

4 Press until the field you want to change is displayed.

5 Type a new value. For most fields, legal options are displayed in parentheses.

6 Press or Q to quit the display.

7 Type nvupdate to save the new value or nvopen to cancel the change by reading the old value.

nvinit is used to initialize the nonvolatile memory to the default state defined by the monitor. First nvinit clears the memory and then writes the Emerson and monitor data back to the EEPROM.

Descriptionnvinit sernum “revlev” ecolev writes

nonvolatile configuration data structures might be in an unknown state and you must return them to a known state.

ecolev standard ECO level

writes the number of writes to nonvolatile memory

nvopen reads and checks the monitor and Emerson-defined sections. If the nonvolatile sections are not valid, an error message is displayed.

Descriptionnvopen

nvset is used to modify the Emerson-defined and monitor-defined nonvolatile sections.

Show 9 more labels / short text on this page
Group ‘Console’ · PortA(A, B) · Baud9600 · StopBits2-bits(1-Bit, 2-Bits) · ChBaudOnBreakFalse(False, True) · RstOnBreakFalse(False, True) · ! · sernum serial number · revlev revision level
Page 89 of the Emerson Power Module (PME1) user manual — nvupdate
Page 89 · click to enlarge
Page 89
Emerson Power Module (PME1) — nvupdate diagram (page 89)
Fig. 106 · nvupdate
Descriptionnvset group field value

To modify the list with the nvset command, you must specify the group and field to be modified and the new value. The group, field, and value can be abbreviated, as in the exam- ples below:

Example=>nvset console port A

=>nvset con dat 6

nvupdate attempts to write the Emerson- and monitor-defined nonvolatile sections back to the EEPROM. First the data is verified, and then it is written to the device. The write is verified and all errors are reported.

Descriptionnvupdate

Configuring the Default Boot Device The default boot device is defined in the nonvolatile memory group BootParams, in the field BootDev. When the PmT1 and PmE1 is reset or powered up, the monitor checks this field and attempts to boot from the specified device.

Currently, the monitor supports Serial, ROM, and Bus as standard. If you edit the BootDev field and define a device that is unsupported on your board, the monitor will display the message:

Defining BootDev as Serial calls the command bootserial, defining BootDev as ROM calls the command bootrom, and defining BootDev as Bus calls the command bootbus. See the “Boot Commands” Section for details on these commands.

Example: In this example, nvdisplay and nvupdate are used to change the default boot device from

the bus to the ROM. The changes are made to the BootParams group.

1 At the monitor prompt, type:

2 Press until the BootParams group is displayed.

Group ‘BootParams’ BootDevBus(None,Serial,ROM,Bus,EPROM) LoadAddress0x40000 ROMBase0xfff30000 ROMSize0x40000 DevType0

Unknown boot device · =>nvdisplay

Page 90 of the Emerson Power Module (PME1) user manual — nvupdate
Page 90 · click to enlarge
Page 90
Emerson Power Module (PME1) — nvupdate diagram (page 90)
Fig. 107 · nvupdate
Emerson Power Module (PME1) — nvupdate diagram (page 90)
Fig. 108 · nvupdate

[SP, CR to continue] or [E, e to Edit]

4 Press until the BootDev field is displayed.

12 Press or Q to quit the display.

Example: In this example, nvdisplay and nvupdate are used to change the default boot device from

the bus to the serial port. The changes are made to the BootParams group.

2 Press until the BootParams group is displayed.

4 Press until the BootDev field is displayed.

6 Press until the DevType field is displayed.

7 Type the new value for DevType; for example, 2 selects downloads in Emerson binary format.

8 Edit any other fields you want to modify. Whether you use the DevType and DevNumber fields depends on the application.

9 Press or Q to quit the display.

Page 91 of the Emerson Power Module (PME1) user manual — Power-up Test: Sequence Bit: Fail Mask Bit:
Page 91 · click to enlarge
Page 91
Emerson Power Module (PME1) — Power-up Diagnostic/Test Commands diagram (page 91)
Fig. 109 · Power-up Diagnostic/Test Commands

POWER-UP DIAGNOSTIC/TEST COMMANDS

The following on-card functional tests are available to be run at any time, including power- up and reset. The nonvolatile configuration memory can be used to enable or disable the execution of these tests on power-up and reset (see the nvdisplay command’s Misc group in Table 8-1).

The results of the tests are stored at an offset of 0x60 in the I2C EEPROM. To read the PASS/FAIL flags, do four byte reads from the EEPROM at 0x60, 0x61, 0x62, and 0x63. The byte at 0x60 should contain the magic number 0xa5 indicating that the device is functional and that PASS/FAIL reporting is supported. The values for the long word when a failure occurs are listed in Table 8-3.

Table 8-3NVRAM Power-up Diagnostic PASS/FAIL Flags

Test: Value Read on Failure:

The power-up PASS/FAIL flags are also written to PLX Mailbox 0. The module writes the progress and PASS/FAIL status of each of its power-up tests to PCI so that the baseboard can determine the power-up status of the module and proceed accordingly. At the conclu- sion of power-up, the same magic number (0xa5) used in the NVRAM PASS/FAIL flags is written to the least significant bit (LSB) of PLX Mailbox 0. The PLX Mailbox 0 register can be polled until the magic number is displayed and then checked to see if there are any fail mask bits set. The following bits in Table 8-4 are used to indicate the power-up test sequence and failure.

Table 8-4PLX Mailbox 0 Sequence and Fail Mask Bits

Power-up Test: Sequence Bit: Fail Mask Bit:

Parity DRAM Memory 0x0A000000 0x00000200

Data DRAM Memory 0x0B000000 0x00000400

For example, if the module had a memory failure, the PLX Mailbox 0 register would contain 0x0B000400. For parity and DRAM failures, the same register would contain 0x0A000600. The magic number 0xa5 will not be in the LSB of the PLX Mailbox 0 register because if a memory error is encountered, then the debug monitor is entered. If all power-up tests pass, the PLX Mailbox 0 will be 0xA5000000.

Show 7 more labels / short text on this page
Serial 0xa5000001 · Counter/Timer 0xa5000002 · Cache 0xa5000010 · EEPROM 0xa5000020 · Counter/Timer 0x02000000 0x00000002 · Cache 0x05000000 0x00000010 · EEPROM 0x06000000 0x00000020
Page 92 of the Emerson Power Module (PME1) user manual — REMOTE HOST COMMANDS
Page 92 · click to enlarge
Page 92
Emerson Power Module (PME1) — cachetest diagram (page 92)
Fig. 110 · cachetest

cachetest tests the operation of the data cache. The test writes a word to every cache line and verifies that the data was written into the data cache and not into DRAM.

Descriptioncachetest

eepromtest checks the interface to the I2C EEPROM by writing a byte to the device, and then reading it back and verifying the data.

Descriptioneepromtest

memtest performs an address boundary test throughout all of DRAM. The test first clears all of mem- ory by writing zeros. The test then performs a rotating bit test on each address boundary and writes the test address as data to the test address location. The test finishes by verify- ing each address location contains its address as data. Any failure during the memtest causes an error message to be displayed and the debug monitor is entered. The debug monitor does not require RAM to execute.

Descriptionmemtest

REMOTE HOST COMMANDS

The monitor commands transmode, download, and call are used for downloading applica- tions and data in hex-Intel format, S-record format, or binary format.

Hex-Intel and S-record are common formats for representing binary object code as ASCII for reliable and manageable file downloads. Both formats send data in blocks called records, which are ASCII strings. Records may be separated by any ASCII characters except for the start-of-record characters–“S” for S-records and “:” for hex-Intel records. In prac- tice, records are usually separated by a convenient number of carriage returns, linefeeds, or nulls to separate the records in a file and make them easily distinguishable by humans.

All records contain fields for the length of the record, the data in the record, and some kind of checksum. Some records also contain an address field. Most software requires the hexa- decimal characters that make up a record to be in uppercase only.

transmode stands for “transparent mode,” which means that the console port is connected to the download port via software. In this mode, a terminal connected to the console port can communicate with a host connected to the download port through the PmT1 and PmE1 as though they were transparent. This allows you to edit your source code, recom-

Page 93 of the Emerson Power Module (PME1) user manual — Binary Download Format The binary download format consists of two parts:
Page 93 · click to enlarge
Page 93
Emerson Power Module (PME1) — call diagram (page 93)
Fig. 111 · call

pile, initiate and complete the download, and return to the monitor, all from one terminal. This is convenient for downloading, because a single control sequence issues a carriage return to the host and issues a download command to the PmT1 and PmE1.

call allows execution of a program after a download from one of the board’s interfaces. This command allows up to eight arguments to be passed to the called address from the com- mand line. Arguments can be symbolic, numeric, characters, flags, or strings. The default numeric base is hexadecimal.

If the application wants to return to the monitor, it should save and restore the processor registers. Also, it is important that special-purpose registers remain unchanged.

Descriptioncall address arg0 arg1 arg2 arg3 arg4 arg5 arg6 arg7

download provides a serial download from a host computer to the board.

Descriptiondownload -[b,h,m] address

download uses binary, hex-Intel, or Motorola S-record format, as specified by the following flags:

Definition-b binary

(address not used)

(load address in memory = address + record address)

(load address in memory = address + record address)

If no flag is specified, the default format is hex-Intel.

Refer to page 8-20 for an example of how to configure the download port using NVRAM commands. “Binary Download Format” Section , “Hex-Intel Format” Section , and “Motor- ola S-record Format” Section describe the download formats in detail.

Binary Download Format The binary download format consists of two parts:

  • Magic number (0x12345670) + number of sections
  • Information for each section including: the load address (unsigned long), the section size (unsigned long), a checksum (unsigned long) that is the long word sum of the memory bytes of the data section.

-h hex-Intel · -m Motorola S-record

Page 94 of the Emerson Power Module (PME1) user manual — transmode
Page 94 · click to enlarge
Page 94
Emerson Power Module (PME1) — transmode diagram (page 94)
Fig. 112 · transmode

transmode provides an interface to UNIX® through the board by connecting the console to a down- load port. A null modem cable might be necessary for the connection.

Descriptiontransmode

Several key sequences are used to leave transparent mode and to initiate a download:

CTRL-@-m Download Motorola S-record

CTRL-@-ESC Return to monitor

This command uses software FIFOs to buffer characters between the two systems. This seems to work reasonably well for most processors, but can lose characters if large num- bers of characters are displayed. In general, the only complete solution is to use serial inter- rupts rather than polling. Since this is not likely to happen, be aware that the transmode command will allow execution of commands without problems, but may have problems if text editing is attempted.

Example: If the host is a UNIX system and you have a hex-Intel file called ‘foo.hex’ in a directory

‘foodir’ to download, you can use the following sequence:

=>PmT1 or PmE1[2.x] transmode UNIXprompt>cd foodir UNIXprompt>cat foo.hex Press CTRL-@-Return.

{dots continue during download}

=>PmT1 or PmE1[2.x]

Configuring the Download Port In this example, the NVRAM command nvdisplay changes fields in the Download group, which contains fields for port selection, baud rate, parity, number of data bits, and number of stop bits:

1 At the monitor prompt, type:

2 Press until the Download group is displayed.

Show 4 more labels / short text on this page
CTRL-@-RETURN Download S-record · CTRL-@-h Download hex-Intel · CTRL-@-b Download binary · =>nvdisplay
Page 95 of the Emerson Power Module (PME1) user manual — Extended Address Record
Page 95 · click to enlarge
Page 95
Emerson Power Module (PME1) — Hex-Intel Format diagram (page 95)
Fig. 113 · Hex-Intel Format

3 Press E to edit the group.

4 Press until the Baud field is displayed.

5 Type a new value.

6 Change other fields in the same way.

7 over all fields whether you edit them or not, until the monitor prompt reappears.

8 Type nvupdate to save the new value.

Hex-Intel Format Hex-Intel format supports addresses up to 20 bits (one megabyte). This format sends a 20- bit absolute address as two (possibly overlapping) 16-bit values. The least significant 16 bits of the address constitute the offset, and the most significant 16 bits constitute the seg- ment. Segments can only indicate a paragraph, which is a 16-byte boundary. Stated in C, for example:

address = (segment

segment (ssss) + offset (oooo) = address (aaaaa)

For addresses with fewer than 16 bits, the segment portion of the address is unnecessary. The hex-Intel checksum is a two’s complement checksum of all data in the record except for the initial colon (:). In other words, if you add all the data bytes in the record, including the checksum itself, the lower eight bits of the result will be zero if the record was received correctly.

Four types of records are used for hex-Intel format: extended address record, data record, optional start address record, and end-of-file record. A file composed of hex-Intel records must end with a single end-of-file record.

Extended Address Record

:02000002sssscs:is the record start character. 02is the record length. 0000is the load address field, always 0000. 02 is the record type. ssssis the segment address field. csis the checksum.

The extended address record is the upper sixteen bits of the 20-bit address. The segment value is assumed to be zero unless one of these records sets it to something else. When such a record is encountered, the value it holds is added to the subsequent offsets until the next extended address record.

or

Page 96 of the Emerson Power Module (PME1) user manual — 00000001FF
Page 96 · click to enlarge
Page 96
Emerson Power Module (PME1) — Data Record diagram (page 96)
Fig. 114 · Data Record

Here, the first 02 is the byte count (only the data in the ssss field is 3counted). 0000 is the address field; in this record the address field is meaningless, so it is always 0000. The sec- ond 02 is the record type; in this case, an extended address record. cs is the checksum of all the fields except the initial colon.

Example=>:020000020020DC

In this example, the segment address is 002016. This means that all subsequent data record addresses should have 20016 added to their addresses to determine the absolute load address.

Data Record

:11aaaa00d1d2d3...dncs

:is the record start character. 11is the record length. aaaais the load address. This is the load address of the first data byte in the record (d1) relative to the current segment, if any. 00is the record type. d1...dnare data bytes. csis the checksum.

Example=>:0400100050D55ADF8E

In this example, there are four data bytes in the record. They are loaded to address 1016; if any segment value was previously specified, it is added to the address. 5016 is loaded to address 1016, D516 to address 1116, 5A16 to address 1216, and DF16 to address 1316. The checksum is 8E16.

:04000003ssssoooocs

:is the record start character. 04is the record length. 0000is the load address field, always 0000. 03is the record type. ssssis the start address segment. oooois the start address offset. csis the checksum.

Example=>:040000035162000541

In this example, the start address segment is 516216, and the start address offset is 000516, so the absolute start address is 5162516.

End-of-file Record

00000001FF

:is the record start character. 00is the record length. 0000is the load address field, always 0000.

Start Address Record

Page 97 of the Emerson Power Module (PME1) user manual — Data Record
Page 97 · click to enlarge
Page 97
Emerson Power Module (PME1) — Data Record diagram (page 97)
Fig. 115 · Data Record
Emerson Power Module (PME1) — Data Record diagram (page 97)
Fig. 116 · Data Record

This is the end-of-file record, which must be the last record in the file. It is the same for all output files.

Here is a line-by-line explanation of the example file:

sets the segment value to one, so 1016 must be added to all subsequent load addresses.

Page 98 of the Emerson Power Module (PME1) user manual — Where:
Page 98 · click to enlarge
Page 98
Emerson Power Module (PME1) — Motorola S-record Format diagram (page 98)
Fig. 117 · Motorola S-record Format

indicates that the start address segment value is one, and the start address offset value is 2, so the absolute start address is 1216.

=>:04003000902BB4FD60

loads byte 9016 to address 4016

loads byte 2B16 to address 4116

loads byte B416 to address 4216

loads byte FD16 to address 4316

=>:00000001FF

terminates the file.

Motorola S-record Format S-records are named for the ASCII character “S,” which is used for the first character in each record. After the “S” character is another character that indicates the record type. Valid types are 0, 1, 2, 3, 5, 7, 8, and 9. After the type character is a sequence of characters that represent the length of the record, and possibly the address. The rest of the record is filled out with data and a checksum.

The checksum is the one’s complement of the 8-bit sum of the binary representation of all elements of the record except the S and the record type character. In other words, if you sum all the bytes of a record except for the S and the character immediately following it with the checksum itself, you should get FF16 for a proper record.

S0-records (User Defined)

S0nnd1d2d3...dncs

Where:

S0 indicates the record type

nn is the count of data and checksum bytes

d1...dn are the data bytes

cs is the checksum

0 records are optional, and can contain any user-defined data.

Example=>S008763330627567736D

In this example, the length of the field is 8, and the data characters are the ASCII represen- tation of “v30bugs.” The checksum is 6D16.

Page 99 of the Emerson Power Module (PME1) user manual — Where:
Page 99 · click to enlarge
Page 99
Emerson Power Module (PME1) — S1-S2-and S3-records (Data Records) diagram (page 99)
Fig. 118 · S1-S2-and S3-records (Data Records)

S1-S2-and S3-records (Data Records)

S1nnaaaad1d2d3...dncs S2nnaaaaaad1d2d3...dncs S3nnaaaaaaaad1d2d3...dncs

Where:

S1 indicates the record type

nn is the count of data and checksum bytes

a...a are the data bytes

cs is the checksum

These are data records. They differ only in that S1-records have 16-bit addresses, S2- records have 24-bit addresses, and S3-records have 32-bit addresses.

Example=>S10801A00030FFDC95B6

In this example, the bytes 0016, 3016, FF16, DC16, and 9516 are loaded into memory starting at address 01A016.

=>S30B30000000FFFF5555AAAAD3

In this example, the bytes FF16, FF16, 5516, 5516, AA16, and AA16 are loaded into memory starting at address 3000,000016. Note that this address requires an S3-record because the address is too big to fit into the address range of an S1-record or S2-record.

S5-records (Data Count Records)

S5nnd1d2d3...dncs

Where:

S5 indicates the record type

nn is the count of data and checksum bytes

d1...dn are the data bytes

cs is the checksum

S5-records are optional. When they are used, there can be only one per file. If an S5-record is included, it is a count of the S1-, S2-, and S3-records in the file. Other types of records are not counted in the S5-record.

Example=>S5030343B6

In this example, the number of bytes is 3, the checksum is B616, and the count of the S1- records, S2-records, and S3-records in the file is 34316.

Page 100 of the Emerson Power Module (PME1) user manual — S7-S8-and S9-records (Termination and Start Address Records)
Page 100 · click to enlarge
Page 100
Emerson Power Module (PME1) — S7-S8-and S9-records (Termination and Start Address Records) diagram (page 100)
Fig. 119 · S7-S8-and S9-records (Termination and Start Address…
Emerson Power Module (PME1) — S7-S8-and S9-records (Termination and Start Address Records) diagram (page 100)
Fig. 120 · S7-S8-and S9-records (Termination and Start Address…

05, 04, 03 count of address digits and the cs field

a...a is a 4-, 6-, or 8-digit address field

These are trailing records. There can be only one trailing record per file, and it must be the last record in the output file. Included in the data for this record is the initial start address for the downloaded code.

In this example, the start address is 3C16.

In this example, the start address is 80000016.

Here is a line-by-line explanation of the example file:

S0097A65726F6A756D707A contains the ASCII representation of the string “zerojump.”

=S10F000000001000000000084EFAFFFE93 loads the following data to the following addresses:

Page 101 of the Emerson Power Module (PME1) user manual — ARITHMETIC COMMANDS
Page 101 · click to enlarge
Page 101
Emerson Power Module (PME1) — Utilities diagram (page 101)
Fig. 121 · Utilities

byte FA16 to address 0916

byte FF16 to address 0A16

byte FE16 to address 0B16

S5030001FB indicates that only one S1-record, S2-record, or S3-record was sent.

S9030008F4 indicates that the start address is 0000000816.

UTILITIES

configboard configures the board to the state specified by the nonvolatile memory configuration. This includes the serial ports, and processor caches, if necessary.

configboard can be used to reconfigure the board’s various interfaces after modification of the nonvolatile memory configuration (using nvdisplay or nvset). This command accepts no parameters.

Definitionconfigboard

ARITHMETIC COMMANDS

add adds two integers in decimal (the default), binary, octal, or hexadecimal.

The default numeric base is decimal. Specify hexadecimal by typing “:16” at the end of the value, octal by typing “:8” or binary by typing “:2.” The result of the operation is displayed in hex, decimal, octal, and binary.

Definitionadd number1 number2

div divides two integers in decimal (the default), binary, octal, or hexadecimal. number1 is divided by number2. The command also checks the operation to avoid dividing by zero.

The default numeric base is decimal. Specify hex by typing “:16” at the end of the value, octal by typing “:8” or binary by typing “:2.” The result of the operation is displayed in hex, decimal, octal, and binary.

Definitiondiv number1 number2
Page 102 of the Emerson Power Module (PME1) user manual — Message: Source and Suggested Solution:
Page 102 · click to enlarge
Page 102
Emerson Power Module (PME1) — mul diagram (page 102)
Fig. 122 · mul

mul multiplies two integers in decimal (the default), binary, octal, or hexadecimal from the monitor.

The default numeric base is decimal. Specify hex by typing “:16” at the end of the value, octal by typing “:8” or binary by typing “:2.” The result of the operation is displayed in hex, decimal, octal, and binary.

Definitionmul number1 number2

rand is a linear congruent random number generator that uses a function Seed and a variable Value. The random number returned is an unsigned long.

Definitionrand

sub subtracts two integers in decimal (the default), binary, octal, or hexadecimal. number2 is subtracted from number1.

The default numeric base is decimal. Specify hexadecimal by typing “:16” at the end of the value, octal by typing “:8” or binary by typing “:2.” The result of the operation is displayed in hex, decimal, octal, and binary.

Definitionsub number1 number2

ERRORS AND SCREEN MESSAGES

Most commands return an explanatory message for misspelled or mistyped commands, missing arguments, or invalid values.Table 8-5 lists errors that can be attributed to other causes, especially errors that indicate a problem in the nonvolatile memory configuration.

Some errors can be resolved by contacting Emerson Network Power, Embedded Comput- ing Technical Support at http://www.emersonembeddedcomputing.com/contact/postsa- lessupport.html on the internet or send e-mail to support@artesyncp.com.

Table 8-5Error and Screen Messages

Message: Source and Suggested Solution:

Error while clearing NV memory

NV memory has become corrupted. Use the nvinit command to restore defaults.1

Error while reading NV memory

Error while storing NV memory

Hit ‘H’ to skip auto-boot Consult the introduction to this chapter for information about power-up conditions.

Page 103 of the Emerson Power Module (PME1) user manual — MONITOR FUNCTION REFERENCE
Page 103 · click to enlarge
Page 103
Emerson Power Module (PME1) — Monitor Function Reference diagram (page 103)
Fig. 123 · Monitor Function Reference

Message: Source and Suggested Solution:

No help for ___ The topic for help was misspelled or is not available. Check the spelling. If the topic was a command name, use the help command to check the spelling of the command. You must use the full command name, not an abbreviation.

Power-up Memory Test FAILED A failed memory test could mean a hardware malfunction.1

Unknown boot device The boot device is invalid. Use nvdisplay to check and edit the ‘BootParams’ group, BootDev field. Save a new value with nvupdate.

Unexpected Exception at There are many possible sources for this error.

If the error is displayed during boot, it could mean that autoboot is enabled and invalid parameters are being used.

If the error is displayed at reset or power-up and autoboot is not enabled, report the error to Emerson Customer Support.

If the error is displayed after a command has been executed, an attempt to perform an operation that causes an exception has probably been made.

Only minimum configuration has been completed. The configuration data structures are invalid.

Consult the introduction to this chapter for information about reset conditions.

1. Contact/report the error to Emerson Network Power Customer Support at http://www.emersonembeddedcomputing.com/contact/postsalessupport.html on the Internet or send e-mail to support@artesyncp.com.

MONITOR FUNCTION REFERENCE

The PmT1 and PmE1 monitor functions fall into three groups: PmT1 and PmE1-specific monitor functions, processor-specific functions, and standard Emerson monitor functions. In order to save space, associated functions have been combined in groups under a single function name. If you are looking for a function that is not listed by name in the following sections, refer to the index to locate the desired information.

The functions require spaces between the function name and its arguments. No parenthe- ses or other punctuation is necessary.

Example=>display a0000000

=>ConnectHandler f8 1000

Page 104 of the Emerson Power Module (PME1) user manual — getchar
Page 104 · click to enlarge
Page 104
Emerson Power Module (PME1) — PmT1 and PmE1-Specific Functions diagram (page 104)
Fig. 124 · PmT1 and PmE1-Specific Functions

Unlike the monitor commands, no argument checking takes place for functions that are called directly from the command line.

PMT1 AND PME1-SPECIFIC FUNCTIONS

ChangeBaud

ChangeBaud(Baud, Port) struct SCCPort *Port; int Baud;

Description: The function ChangeBaud allows the baud rate for the port defined by Port to be modified

to the value defined by Baud. This function accepts a selected number of values for the baud rate and will configure the port accordingly. It is the caller’s responsibility to check if the terminal can support the specified baud rate.

The ConfigSerDevs function uses the current definitions in the nonvolatile memory config- uration to configure the serial ports. It is important that the configuration be valid when this function is called, or unpredictable behavior may result.

Both serial ports can be configured to use 5 to 8 data bits, 1 or 2 stop bits, the handshake control lines, and odd, even, or no parity.

EEPROMAcc

unsigned char EEPROMAcc(mode, offset, ch) unsigned long mode, offset; unsigned char ch;

DescriptionThis function provides the physical interface to the board’s nonvolatile memory device. The

mode indicates one of four access types: READ, READ_PROBE, WRITE, and WRITE_PROBE. The probe mode was left for compatibility with earlier versions of the monitor. If mode is zero, a byte is read from nonvolatile memory. If mode is one, a byte is written to nonvolatile memory. The Offset indicates the byte location to be modified and assumes that nonvola- tile memory is a linear array of memory locations. The last parameter ch is the character to be written. The number of bytes written to the device or the value read from the device is returned, depending on mode.

getchar

Show 4 more labels / short text on this page
ConfigSerDevs() · getchar · putchar(c) · char c;
Page 105 of the Emerson Power Module (PME1) user manual — Misc
Page 105 · click to enlarge
Page 105
Emerson Power Module (PME1) — InitBoard diagram (page 105)
Fig. 125 · InitBoard
DescriptionThese functions provide the low-level I/O necessary to read, write, and configure the

MPC860P. These functions are used to interface to both the console and modem device specified by the argument Port.

The getchar function reads a character from specified device Port. This function is also set up to check for a break and allows the monitor to perform functions like reset or baud changes when a break is detected.

The function putchar writes the character c to the specified device.

The functions KBHit and RKBHit poll the console and modem devices for available charac- ters. If the receiver indicates a character is available, these functions return TRUE; other- wise, they return FALSE.

The functions TxMT and RTxMT poll the console and modem devices if the transmitter can accept more characters. If the transmitter indicates a character can be sent, these functions return TRUE; otherwise, they return FALSE.

InitBoard

DescriptionThese functions provide initialization of the board’s interfaces at various points in the mon-

itor. Both these functions use the nonvolatile memory configuration to determine how to configure an interface, so the data structures must contain valid data before either of these functions are called.

The InitBoard function initializes the minimum set of hardware to the default state defined by the nonvolatile device structures. The hardware initializes the serial port.

The ConfigCaches function initializes the processor caches to be On or Off as defined by the nonvolatile memory configuration.

Misc

Show 11 more labels / short text on this page
KBHit(void) · RKBHit() · TxMT() · RTxMT() · InitBoard() · ConfigCaches() · unsigned char *MemTop() · unsigned char *MemBase() · time_delay · IsPowerUp() · SetNotPowerUp()
Page 106 of the Emerson Power Module (PME1) user manual — NvRamAcc
Page 106 · click to enlarge
Page 106
Emerson Power Module (PME1) — NvHkOffset diagram (page 106)
Fig. 126 · NvHkOffset

Description: This is a collection of miscellaneous board support functions.

The functions MemTop and MemBase are used to determine the addresses of the last and first long words in free memory. The size of DRAM is determined by the configuration regis- ter. The base of free memory is determined by the compiler-created variable End, which indicates the end of the monitor’s bss section.

The time_delay function provides a fixed delay for timing. As a delay generator, this func- tion can be used to delay in increments of microseconds as specified by the MicroSec argu- ment.

The IsPowerUp function determines if a power-up or reset just occurred.

The SetNotPowerUp function resets the power-up register.

NvHkOffset

DescriptionThese functions allow the nonvolatile library functions to operate on the nonvolatile mem-

ory sections without actually compiling the board configuration files into the library.

The NvHkOffset and NvMonOffset functions describe where in the nonvolatile memory device the Emerson- and monitor-defined data sections begin. In general, the Emerson- defined data section and the monitor data section reside in the user-writeable section of the nonvolatile memory device. The returned value is the offset in bytes from the begin- ning of the device in which the section is loaded.

The functions NvMonSize and NvMonAddr return the size and location of the nonvolatile monitor configuration data structure. This again allows other monitor facilities and applica- tion programs to get at the monitor configuration structure without having to know too much about the monitor.

NvRamAcc

unsigned char NVRamAcc(Mode, Cnt, Val) unsigned long Mode, Cnt; unsigned char Val;

DescriptionNVRamAcc function provides access to the lower level utilities of the X24C16 device. The

Mode indicates one of four access types: READ, READ_PROBE, WRITE, and WRITE_PROBE. If Mode is zero, a byte is read from nonvolatile memory. If Mode is one, a byte is written to nonvolatile memory.

Show 4 more labels / short text on this page
NvHkOffset() · NvMonOffset() · NvMonSize() · NvMonAddr()
Page 107 of the Emerson Power Module (PME1) user manual — Exceptions
Page 107 · click to enlarge
Page 107
Emerson Power Module (PME1) — SetUnExpIntFunct diagram (page 107)
Fig. 127 · SetUnExpIntFunct

The Cnt indicates the byte location to be modified and assumes the nonvolatile memory is a linear array of memory locations. If there are gaps between bytes on the physical device, they are dealt with here. The last parameter Val is a pointer to the character location to be written.

This function returns the number of bytes written to the device or the value read from the device, depending on Mode. Only bytes that differ are written.

SetUnExpIntFunct

SetUnExpIntFunct(Funct) unsigned long Funct;

DescriptionIf desired, a program can call the SetUnExpIntFunct function to attach its own interrupt

handler to all unexpected interrupts. This function attaches the handler specified by Funct. The new interrupt handler must determine the source of the unexpected interrupt and remove it.

MPC860P-SPECIFIC FUNCTIONS

Cache

DescriptionAs the names indicate, these functions enable, disable, and flush the data and instruction

caches. The enable_dcache function enables the data cache in either copyback or write- through mode. If mode is zero, copyback mode is selected. If mode is one, write-through mode is selected. The invalidate_dcache function flushes all data cache lines and the invalidate_icache function flushes all instruction cache lines.

Exceptions

typedef unsigned long VECTORNUM;

typedef void (*HANDLER)(VECTORNUM, ...); /* up to one (1)

Show 9 more labels / short text on this page
disable_dcache · disable_icache · enable_dcache · enable_icache · invalidate_dcache · invalidate_icache · VecInit(void) · typedef void *HANDLERPARM; · optional parameter */
Page 108 of the Emerson Power Module (PME1) user manual — SetUnExpIntFunct
Page 108 · click to enlarge
Page 108
Emerson Power Module (PME1) — SetUnExpIntFunct diagram (page 108)
Fig. 128 · SetUnExpIntFunct
Emerson Power Module (PME1) — SetUnExpIntFunct diagram (page 108)
Fig. 129 · SetUnExpIntFunct
DescriptionThese functions are the MPC860P processor-specific functions that provide interrupt and

The following table defines those exceptions which have interrupt vectors assigned to them by the monitor. When connecting an interrupt handler to these exceptions, the spec- ified vectors must be used.

Page 109 of the Emerson Power Module (PME1) user manual — Interrupts
Page 109 · click to enlarge
Page 109
Emerson Power Module (PME1) — Interrupts diagram (page 109)
Fig. 130 · Interrupts
VectorCause of Exception: (continued)

0x27 Software Interrupt level 3

0x28 Hardware interrupt level 4 (IRQ4*)

0x29 Software Interrupt level 4

0x2a Hardware interrupt level 5 (IRQ5*)

0x2b Software Interrupt level 5

0x2c Hardware interrupt level 6 (IRQ6*)

0x2d Software Interrupt level 6

0x2e Hardware interrupt level 7 (IRQ7*)

0x2f Software Interrupt level 7

The function VecInit initializes all entries in the interrupt table to reference the unexpected interrupt handler. This ensures that the board will not hang when unexpected interrupts are received. The unexpected interrupt handler saves the state of the processor at the point the interrupt was detected and then calls the IntrErr function, which displays the error and restarts the monitor.

The function ConnectHandler initializes the entry in the vector table to point to the Handler address. The argument Vector indicates the vector number to be connected and the argu- ment Handler is the address of the function that will handle the interrupts. With this struc- ture, assembly language programming for interrupts is avoided. ConnectHandler returns HANDLERSTRUCT, which is the existing handler information.

The function DisConnectHandler modifies the interrupt table entry associated with Vector to use the unexpected interrupt handler. It also de-allocates the memory used for the inter- rupt wrapper allocated by ConnectHandler. Because both ConnectHandler and DisCon- nectHandler use the Malloc and Free facilities, it is necessary for memory management to be initialized.

The function probe accesses memory locations that may or may not result in bus error. This function returns TRUE if the location was accessed and FALSE if the access resulted in a bus error. The argument DirFlag indicates whether a read (0) or a write (1) should be attempted. The argument SizeFlag selects either a byte access (1), a word access (2), or a long access (4). The argument Address indicates the address to be accessed, and the argument Data is a pointer to the read or write data.

Interrupts

Show 4 more labels / short text on this page
0x30 PCI9060ES LINTO* · 0x31 PCI9060ES LSERR* · MaskInts() · UnMaskInts()
Page 110 of the Emerson Power Module (PME1) user manual — STANDARD MONITOR FUNCTIONS
Page 110 · click to enlarge
Page 110
Emerson Power Module (PME1) — Status diagram (page 110)
Fig. 131 · Status
DescriptionThe functions UnMaskInts and MaskInts are used to enable and disable external interrupts

at the processor.

Status

Description: The functions getMSR, setMSR(Data), and clrMSR return the value of the Machine State

register (MSR). setMSR and clrMSR either set or clear the bits in the MSR. getTBU returns the value of the upper 32 bits of the TimeBase register and getTBL is used for the lower 32 bits. Functions getDEC, getSRR0, getSRR1, getIC_CST and getDC_CST return the value for the appropriate register.

getICTRL and writeICTRL read and write the Instruction Control register. This allows user control of the ICTRL register which controls instruction serialization and instruction show cycles.

STANDARD MONITOR FUNCTIONS

atoh

unsigned long atoh(p) char *p;

unsigned long atod(p) char *p;

unsigned long atoo(p) char *p;

unsigned long atob(p) char *p;

Show 12 more labels / short text on this page
getMSR · setMSR(Data) · clrMSR(Data) · getTBU · getTBL · getDEC · getSRR0 · getSRR1 · getIC_CST · getDC_CST · getICTRL() · writeICTRL()
Page 111 of the Emerson Power Module (PME1) user manual — BootUp
Page 111 · click to enlarge
Page 111
Emerson Power Module (PME1) — BootUp diagram (page 111)
Fig. 132 · BootUp

unsigned long atoX(p, Base) char *p; int Base;

BinToHex(Val) unsigned long Val;

HexToBin(Val) unsigned long Val;

FindBitSet(Number) unsigned long Number;

DescriptionThese functions are a collection of numeric conversion programs used to convert character

strings to numeric values, convert hexadecimal to BCD, BCD to hexadecimal, and to search for bit values.

The atoh function converts an ASCII string to a hex number. The atod function converts an ASCII string to a decimal number. The atoo function converts an ASCII string to an octal number. The atob function converts an ASCII string to a binary number.

The function atoX accepts both the character string p and the numeric base Base to be used in converting the string. This can be used for numeric bases other than the standard bases 16, 10, 8, and 2.

The BinToHex function converts a binary value to packed nibbles (BCD). The HexToBin function converts packed nibbles (BCD) to binary. This function accepts the parameter Val, which is assumed to contain a single hex number of value 0-99.

The FindBitSet function searches the Number for the first non-zero bit. The bit position of the least significant non-zero bit is returned.

BootUp

DescriptionThe BootUp function is called immediately after the nonvolatile memory device has been

opened and the board has been configured according to the nonvolatile configuration. This function also determines if memory is to be cleared according to the nonvolatile configura- tion and the flag PowerUp.

The monitor provides an autoboot feature that allows an application to be loaded from a variety of devices and executed. This function uses the nonvolatile configuration to deter- mine which device to boot from and calls the appropriate bootstrap program. The monitor supports the EPROM, ROM, BUS, and SERIAL autoboot devices, which are not hardware- specific. The remainder of the devices may or may not be supported by board-specific func- tions described elsewhere.

Arguments: The flag PowerUp indicates if this function is being called for the first time. If so, memory

must be cleared.

BootUp(PowerUp) int PowerUp;

Page 112 of the Emerson Power Module (PME1) user manual — IsLegal
Page 112 · click to enlarge
Page 112
Emerson Power Module (PME1) — InitFifo diagram (page 112)
Fig. 133 · InitFifo

See also: StartMon.c, NvMonDefs.h, NVTable.c, “Boot Commands” Section .

InitFifo

InitFifo(FPtr, StartAddr, Length) struct Fifo *FPtr; unsigned char *StartAddr; int Length;

ToFifo(FPtr, c) struct Fifo *FPtr; unsigned char c;

FromFifo(FPtr, Ptr) struct Fifo *FPtr; unsigned char *Ptr;

DescriptionThese functions provide the necessary interface to initialize, read, and write a software

FIFO. The FIFO is used for buffering serial I/O when using transparent mode, but could be used for a variety of applications. All three functions accept a pointer FPtr as the first argu- ment to a FIFO management structure. This FIFO structure is described briefly below:

struct Fifo { unsigned char *Top; unsigned char *Bottom; int Length; unsigned char *Front; unsigned char *Rear; int Count; } Fifo;

The function InitFifo initializes the FIFO control structure specified by FPtr to use the unsigned character buffer starting at StartAddr that is of size Length.

The function ToFifo writes the byte c to the specified FIFO. This function returns TRUE if there is room in the FIFO (before adding c to the FIFO), or FALSE if the FIFO is full.

The function FromFifo reads a byte from the specified FIFO. If a character is available, it is written to the address specified by the pointer Ptr and the function returns TRUE. If no char- acter is available, the function returns FALSE.

IsLegal

IsLegal(Type,Str) unsigned char Type; char *Str;

Description: This function is used to determine if the specified character string Str contains legal values

to allow the string to be parsed as decimal, hex, uppercase, or lowercase. The function IsLe- gal traverses the character string until a NULL is reached. Each character is verified accord- ing to the Type argument.

The effects of specifying each type are described below:

Page 113 of the Emerson Power Module (PME1) user manual — MemMng
Page 113 · click to enlarge
Page 113
Emerson Power Module (PME1) — MemMng diagram (page 113)
Fig. 134 · MemMng
Table 8-7IsLegal Function Types

Type: Value: Legal Characters:

DECIMAL 0x8 0 - 9

HEX 0x4 0 - 9, A - F, a - f

UPPER 0x2 A - Z

LOWER 0x1 a - z

ALPHA 0x3 A - Z, a - z

If the character string contains legal characters, this function returns TRUE; otherwise, it returns FALSE. The string equivalent of the character functions isalpha(), isupper(), islower(), and isdigit() can be constructed from this function, which deals with the entire string instead of a single character.

MemMng

void *Malloc(NumBytes) unsigned long NumBytes;

void *Calloc(NumElements, Size) unsigned long NumElements, Size;

Free(MemLoc) unsigned long *MemLoc;

CFree(Block) unsigned long *Block;

void *ReAlloc(Block, NumBytes) char *Block; unsigned long NumBytes;

MemAdd(MemAddr, MemSize) unsigned long MemAddr, MemBSize;

DescriptionThe memory management functions allocate and free memory from a memory pool. The

monitor initializes the memory pool to use all on-card memory after the monitor’s bss sec- tion. If any of the autoboot features are used, the memory pool is not initialized and the application program is required to set up the memory pool for these functions.

The functions Malloc, Calloc and ReAlloc allocate memory from the memory pool. Each of these functions returns a pointer to the memory requested if the request can be satisfied and NULL if there is not enough memory to satisfy the request. The function Malloc accepts one argument, NumBytes, indicating the number of bytes requested. The function Calloc accepts two arguments, NumElements and Size, indicating a request for a specified number of elements of the specified size. The function ReAlloc reallocates a memory block by either

MemReset() · MemStats()

Page 114 of the Emerson Power Module (PME1) user manual — NVSupport
Page 114 · click to enlarge
Page 114
Emerson Power Module (PME1) — NVSupport diagram (page 114)
Fig. 135 · NVSupport

returning the block specified by Block to the free pool and allocating a new block of size NumBytes, or by determining that the memory block specified by Block is big enough and returning the same block to be reused.

The functions Free and CFree return blocks of memory that were requested by Malloc, Cal- loc, or ReAlloc to the free memory pool. The address of the block to be returned is specified by the argument MemLoc, which must be the same value returned by one of the allocation functions. An attempt to return memory that was not acquired by the allocation functions is a fairly reliable way of blowing up a program and should be avoided.

The function MemReset sets the free memory pool to the empty state. This function must be called once for every reset operation and before the memory management facilities can be used. It is also necessary to call this function before every call to MemAdd.

The function MemAdd initializes the free memory pool to use the memory starting at MemAddr of size specified by MemSize. This function currently allows for only one contigu- ous memory pool and must be preceded by a function call to MemReset.

The function MemStats monitors memory usage. This function outputs a table showing how much memory is available and how much is used and lost as a result of overhead.

See also: MemTop, MemBase.

NVSupport

SetNvDefaults(Groups, NumGroups) NVGroupPtr Groups; int NumGroups;

DispGroup(Group, EditFlag) NVGroupPtr Group; unsigned long EditFlag;

NVOp(NVOpCmd, Base, Size, Offset) unsigned long NVOpCmd, Size, Offset; unsigned char *Base;

DescriptionThe support functions used for displaying, initializing, and modifying the nonvolatile mem-

ory data structures can also be used to manage other data structures that may or may not be stored in nonvolatile memory.

The method used to create a display of a data structure is to create a second structure that contains a description of every field of the first structure. This description is done using the NVGroup structure. Each entry in the NVGroup structure describes a field name, pointer to the field, size of the field, indication of how the field is to be displayed, and the initial value of the field.

An example data structure is shown below, as well as the NVGroup data structure necessary to describe the data structure. This example might describe the coordinates and depth of a window structure.

Page 115 of the Emerson Power Module (PME1) user manual — Command: Value: Description:
Page 115 · click to enlarge
Page 115
Emerson Power Module (PME1) — NVSupport diagram (page 115)
Fig. 136 · NVSupport

struct NVExample { NV_Internal Internal; unsigned long XPos, YPos; unsigned short Mag; } NVEx;

NVField ExFields[] = { { “XPos”, (char *) &NVEx.XPos, sizeof(NVEx.XPos), NV_TYPE_DECIMAL, 0, 100, NULL}, { “YPos”, (char *) &NVEx.YPos, sizeof(NVEx.YPos), NV_TYPE_DECIMAL, 0, 200, NULL}, { “Depth” (char *) &NVEx.Mag, sizeof(NVEx.Mag), NV_TYPE_DECIMAL, 0, 4, NULL} }

NVGroup ExGroups[] = {

{ “Window”, sizeof(ExFields)/sizeof(NVField), ExFields } };

If passed a pointer to the ExGroups structure, the function DispGroup generates the display shown below. The second parameter EditFlag indicates whether to allow changes to the data structure after it is displayed (same as in the nvdisplay command).

Window Display Configuration XPos 100 YPos 200 Magnitude 4

The SetNvDefaults function, when called with a pointer to the ExGroup structure, initializes the data structure to those values specified in the NVGroup structure. The second parame- ter NumGroups indicates the number of groups to be initialized.

The NVOp function stores and recovers data structures from nonvolatile memory. The only requirement of the data structure to be stored in nonvolatile memory is that the first field of the structure be NVInternal, which is where all the bookkeeping for the nonvolatile memory section is done. The first parameter NVOpCmd indicates the command to be per- formed. A summary of the commands is shown below:

Table 8-8NVOp Command

Command: Value: Description:

NV_OP_FIX 0 Fix nonvolatile section checksum

NV_OP_CLEAR 1 Clear nonvolatile section

NV_OP_CK 2 Check if nonvolatile section is valid

NV_OP_OPEN 3 Open nonvolatile section

NV_OP_SAVE 4 Save nonvolatile section

NV_OP_CMP 5 Compare nonvolatile section data

Page 116 of the Emerson Power Module (PME1) user manual — Serial
Page 116 · click to enlarge
Page 116
Emerson Power Module (PME1) — Seed diagram (page 116)
Fig. 137 · Seed

The second parameter, Base, indicates the base address of the data structure to be oper- ated on, and the Size parameter indicates the size of the data structure to be operated on. The Offset parameter specifies the byte offset in the nonvolatile memory device where the data structure is to be stored. An example of how to initialize, store, and recall the example data structure is shown below.

NVOp(NV_OP_CLEAR, &NVEx, sizeof(NVEx), 0); NVOp(NV_OP_SAVE , &NVEx, sizeof(NVEx), 0); NVOp(NV_OP_OPEN , &NvEx, sizeof(NVEx), 0); NVOp(NV_OP_FIX, &NVEx, sizeof(NVEx), 0); NVOp(NV_OP_SAVE , &NVEx, sizeof(NVEx), 0);

The clear, save, and open operations cause the nonvolatile device to be cleared and filled with the NVEx data structure; then the data structure is filled from nonvolatile memory. The fix and save operation are used to modify the nonvolatile device, which updates the internal data structures and then writes them back to the nonvolatile memory device.

If errors are encountered during the check, save, or compare operations, an error message is returned from the function NVOp. The error codes are listed below:

Table 8-9NVOP Error Codes

Error: Number: Description:

NVE_NONE 0 No errors

NVE_OVERFLOW 1 Nonvolatile device write count exceeded

NVE_MAGIC 2 Bad magic number read from nonvolatile device

NVE_CKSUM 3 Bad checksum read from nonvolatile device

NVE_STORE 4 Write to nonvolatile device failed

NVE_CMD 5 Unknown operation requested

NVE_CMP 6 Data does not compare to nonvolatile device

See also: NVFields.h.

Seed

Seed(Value) unsigned long Value;

Description: The Seed function sets the initial value for the random number generator command rand.

Serial

Show 5 more labels / short text on this page
char get_c() · char get_d() · put_c(char ch) · put_d(char ch) · baud_c(Baud)
Page 117 of the Emerson Power Module (PME1) user manual — Seed
Page 117 · click to enlarge
Page 117
Emerson Power Module (PME1) — Seed diagram (page 117)
Fig. 138 · Seed

Description: The serial support functions defined here provide the ability to read, write, and poll the

monitor’s serial devices. The monitor initializes and controls two serial devices: the con- sole to provide the user interface and the modem (also known as “download” or “remote” device) to connect to a development system. Each console function has a complement function that performs the same operation on the modem device. The modem device func- tions are prefixed with the letter ‘R’ for remote. Each serial port is configured at reset according to the nonvolatile memory configuration.

The functions get_c and get_d read characters from the console and modem devices. When called, these functions do not return until a character has been received from the serial port. The character read is returned to the calling function.

The functions put_c and put_d write the character c from the console and modem devices. When called, these functions do not return until a character has been accepted by the serial port.

The functions baud_c and baud_d modify the console and modem device baud rates. The argument Baud specifies the new baud rate to use for the port. Because these functions accept any baud rate, care must be taken to request only those baud rates supported by the terminal or host system.

The function tx_empty checks if the transmitter is available for sending a character. If the transmitter is available, TRUE is returned; otherwise, FALSE is returned.

See also: getchar, putchar, KBHit, ChangeBaud.

CmpStr(Str1, Str2) char *Str1, *Str2;

StrCmp(Str1, Str2) char *Str1, *Str2;

StrCpy(Dest, Source) char *Dest, *Source;

StrCat(DestStr, SrcStr) char *DestStr, *SrcStr;

DescriptionThese functions provide the basic string manipulation functions necessary to compare,

copy, concatenate, and determine the length of strings.

Show 6 more labels / short text on this page
int Baud; · baud_d(Baud) · int Baud; · tx_empty(void) · Strings · StrLen(Str) char *Str;
Page 118 of the Emerson Power Module (PME1) user manual — TestSuite
Page 118 · click to enlarge
Page 118
Emerson Power Module (PME1) — TestSuite diagram (page 118)
Fig. 139 · TestSuite

The function CmpStr compares the two null terminated strings pointed to by Str1 and Str2. If they are equal, it returns TRUE; otherwise, it returns FALSE. Note that this version does not act the same as the UNIX® strcmp function. CmpStr is non-case-sensitive and only matches characters up to the length of Str1. This is useful for pattern matching and other functions.

The function StrCmp compares the two null terminated strings pointed to by Str1 and Str2. If they are equal, it returns TRUE; otherwise, it returns FALSE. Note that this version acts the same as the UNIX strcmp function.

The function StrCpy copies the null terminated string Source into the string specified by Dest. There are no checks to verify that the string is large enough or is null terminated. The only limit is the monitor-defined constant MAXLN (80), which is the largest allowed string length the monitor supports. The length of the string is returned to the calling function.

The function StrLen determines the length of the null terminated string Str and returns the length. If the length exceeds the monitor defined limit MAXLN, the function returns MAXLN.

The function StrCat concatenates the string SrcStr onto the end of the string DestStr.

TestSuite

TestSuite(BaseAddr, TopAddr, TSPass) unsigned long BaseAddr, TopAddr; int TSPass;

ByteAddrTest(BaseAddr, TopAddr) unsigned char *BaseAddr, *TopAddr;

WordAddrTest(BaseAddr, TopAddr) unsigned short *BaseAddr, *TopAddr;

LongAddrTest(BaseAddr, TopAddr) unsigned long *BaseAddr, *TopAddr;

RotTest(BaseAddr, TopAddr) unsigned long *BaseAddr, *TopAddr;

PingPongAddrTest(BaseAddr, TopAddr) unsigned long BaseAddr, TopAddr;

Interact(Mod, StartAddr, EndAddr) int Mod; unsigned char *StartAddr, *EndAddr;

Description: The function TestSuite and the memory tests which make up this function verify a memory

interface. Each of these functions accepts two arguments BaseAddr and TopAddr which describe the memory region to be tested. The argument TSPass defines the number of passes to perform. Each test and the intended goals of the test are described briefly below.

Page 119 of the Emerson Power Module (PME1) user manual — xprintf
Page 119 · click to enlarge
Page 119
Emerson Power Module (PME1) — xprintf diagram (page 119)
Fig. 140 · xprintf

The function ByteAddrTest performs a byte-oriented test of the specified memory region. Each location is tested by writing the lowest byte of the location address through the entire memory region and verifying each location.

The function WordAddrTest performs a word-oriented test of the specified memory region. Each location is tested by writing the lowest word of the location address through the entire memory region and verifying each location.

The function LongAddrTest performs a long-oriented test of the specified memory region. Each location is tested by writing the location address through the entire memory region and verifying each location.

The function RotTest performs a long word-oriented test of the specified memory region. Each memory location is tested by rotating a single bit through the long-word location.

The function PingPongAddrTest is used to test the reliability of memory accesses in an envi- ronment where the data addresses are varying widely. The intention is to cause the address buffers and multiplexors to change dramatically.

The function Interact is used to test byte interaction in the memory region specified by StartAddr and EndAddr. The main goal of this test is to check for mirrors in memory. This is accomplished by testing the interaction between bytes at different points in memory.

xprintf

xprintf(CtrlStr, Arg0, Arg1 ... ArgN) char *CtrlStr; unsigned long Arg0, Arg1, ... ArgN;

xsprintf(Buffer, CtrlStr, Arg0, Arg1 ... ArgN) char *Buffer, *CtrlStr; unsigned long Arg0, Arg1, ... ArgN;

DescriptionThis function serves as a System V UNIX®-compatible printf() without floating point. It

implements all features of %d, %o, %u, %x, %X, %c, and %s. An additional control statement has been added to allow printing of binary values (%b).

The xprintf and xsprintf functions format an argument list according to a control string Ctrl- Str. The function xprintf prints the parsed control string to the console, while the function xsprintf writes the characters to the Buffer. The control string format is a string that con- tains plain characters to be processed as is, and special characters that are used to indicate the format of the next argument in the argument list. There must be at least as many argu- ments as special characters, or the function may act unreliably.

Special character sequences are started with the character %. The characters after the % can provide information about left or right adjustment, blank and zero padding, argument con- version type, precision, and more things too numerous to list.

Page 120 of the Emerson Power Module (PME1) user manual — xprintf
Page 120 · click to enlarge
Page 120
Emerson Power Module (PME1) — xprintf diagram (page 120)
Fig. 141 · xprintf

If detailed information on the argument formats and argument modifiers is required, see your local C programmer’s manual for details. Not all of the argument formats are sup- ported. The supported formats are %d, %o, %u, %x, %X, %c, and %s.

Emerson Power Module (PME1) — xprintf diagram (page 120)
Fig. 142 · xprintf
Page 121 of the Emerson Power Module (PME1) user manual — I 2 C Inter-integrated Circuit
Page 121 · click to enlarge
Page 121
Emerson Power Module (PME1) — Acronyms diagram (page 121)
Fig. 143 · Acronyms

ASCII American Standard Code for Information Interchange

CPU Central Processing Unit

CSA Canadian Standards Association

DRAM Dynamic Random Access Memory

EEPROM Electrically Erasable Programmable Read-Only Memory

EIA Electronic Industries Alliance

ETSI European Telecommunications Standards Institute

FCC Federal Communications Commission

FDL Facility Data Link

HDLC High-level Data Link Control

I 2 C Inter-integrated Circuit

IEC International Electrotechnical Commission

JTAG Joint Test Action Group

MAC Medium/media Access Control/controller

MDI Management Data Interface

NVRAM Non Volatile RAM

PCB Printed Circuit Board

PCI Peripheral Component Interconnect

PLD Programmable Logic Device

PMC PCI Mezzanine Card

RISC Reduced Instruction Set Computer

RMA Return Merchandise Authorization

TBD To Be Determined

TDM Time Division Multiplexor

UART Universal Asynchronous Receiver/transmitter

USB Universal Serial Bus

Show 6 more labels / short text on this page
EC European Community · EMC Electromagnetic Compatibility · ESD Electrostatic Discharge · LED Light-emitting Diode · ROM Read-Only Memory · UL Underwriters Laboratories
Page 122 of the Emerson Power Module (PME1) user manual — Acronyms
Page 122 · click to enlarge
Page 122
Emerson Power Module (PME1) — Acronyms diagram (page 122)
Fig. 144 · Acronyms
Emerson Power Module (PME1) — Acronyms diagram (page 122)
Fig. 145 · Acronyms
Page 124 of the Emerson Power Module (PME1) user manual — K keys
Page 124 · click to enlarge
Page 124
Emerson Power Module (PME1) — H diagram (page 124)
Fig. 146

Manufacturing 8-3 Misc 8-2, 8-17

M management data interface (MDI). 6-7 Manufacturing monitor group 8-3 mean time between failures (MTBF)1-4 memory

nvopen 8-14 nvset 8-15 nvupdate 8-9, 8-15 rand 8-28 readmem 8-11 setmem 8-12 sub 8-28 swapmem 8-12 testmem 8-12 transmode 8-20 um 8-12 writemem 8-12 writestr 8-13 monitor function 8-37

H HardwareConfig monitor group . . . 8-3 HDLC 5-4 hex-Intel

initializing from the monitor8-6, 8-7 management 8-39 monitor commands 8-10 type 4-3 memory controller 3-4 memory map 1-2

file example 8-23 records 8-18, 8-21

I IDMA channels 5-4 initialization

EEPROM 4-2 memory test error 8-29 Misc monitor group 8-2, 8-17 monitor

atob 8-36 atod 8-36 atoh 8-36 atoo 8-36 atoX 8-37 baud_c 8-42 baud_d 8-43 BinToHex 8-37 ByteAddrTest 8-44 Calloc 8-39 CFree 8-39 ChangeBaud, 8-30 char get_c 8-42 char get_d 8-42 clrMSR 8-36 CmpStr 8-43 ConfigCaches 8-31 ConfigSerDevs, 8-30 ConnectHandler 8-34 disable_dcache 8-33 disable_icache 8-33 DisConnectHandler 8-34 DispGroup 8-40 EEPROMAcc 8-30 enable_dcache 8-33 enable_icache 8-33 FindBitSet 8-37 Free 8-39 FromFifo 8-38 getchar 8-30 getDC_CST 8-36 getDEC 8-36 getIC_CST 8-36 getICTRL 8-36 getMSR 8-36 getSRR0 8-36 getSRR1 8-36 getTBL 8-36

device select signal, PCI 7-10 error, nonvolatile memory 8-28 of board to defaults 8-31 of CPM registers 5-2 of memory from the monitor . . . 8-7 of memory, monitor 8-6 of nonvolatile memory 8-14 of PCI9060ES 7-3 initiator ready signal, PCI 7-10 installation of the board 2-5 INTA* 7-4, 7-10 INTB* 7-10 INTC* 7-10 INTD* 7-10 internal interrupt sources 3-4 interrupt vector register 1-4, 3-4 interrupt vectors 8-34 interrupts

command syntax 8-6, 8-7 command-line history 8-5 EEPROM 8-13 flags 8-10 NVRAM configuration defaults. . 8-2 operation 8-1 power-up/reset sequence 8-1 start-up display 8-4 version number 2-7 monitor command

add 8-27 bootbus 8-7 booteprom 8-8 bootrom 8-9 bootserial 8-9 cachetest 8-18 call 8-19 checksummem 8-10 clearmem 8-10 cmpmem 8-10 configboard 8-27 configboard, 8-13 copymem 8-11 displaymem 8-11 div 8-27 download 8-19 eepromtest 8-18 fillmem 8-11 findmem 8-11 findnotmem 8-11 findstr 8-11 help 8-10 memtest 8-18 mul 8-28 nvdisplay 8-9, 8-13, 8-17 nvinit 8-14

CPM 5-3 PMC/PCI 7-8, 7-10 IRQ7* 3-4

K keys

ESC 8-5 H 8-5 j 8-5

L LINTo* 3-4 LoadAddress field, monitor 8-7 local bus speed 4-3 LOCK signal, PCI 7-11 LSERR* 3-4

PmT1 and PmE1 User’s Manual 10002367-02 i-2

Page 125 of the Emerson Power Module (PME1) user manual — R RAM
Page 125 · click to enlarge
Page 125
Emerson Power Module (PME1) — N diagram (page 125)
Fig. 147

getTBU 8-36 HexToBin 8-37 InitBoard 8-31 InitFifo 8-38 Interact 8-44 invalidate_dcache 8-33 invalidate_icache 8-33 IsLegal 8-38 IsPowerUp 8-31 KBHit 8-31 LongAddrTest 8-44 Malloc 8-39 MaskInts 8-35 MemAdd 8-39 MemBase 8-31 MemReset 8-39 MemStats 8-39 MemTop 8-31 NvHkOffset 8-32 NvMonAddr 8-32 NvMonOffset 8-32 NvMonSize 8-32 NVOp 8-40 NVRamAcc 8-32 PingPongAddrTest 8-44 probe 8-34 put_c 8-42 put_d 8-42 putchar 8-30 ReAlloc 8-39 RKBHit 8-31 RotTest 8-44 RTxMT 8-31 Seed 8-42 setMSR 8-36 SetNotPowerUp 8-31 SetNvDefaults 8-40 SetUnExpIntFunct 8-33 StrCat 8-43 StrCmp 8-43 StrCpy 8-43 StrLen 8-43 TestSuite 8-44 time_delay 8-31 ToFifo 8-38 tx_empty 8-43 TxMT 8-31 UnMaskInts 8-35 VecInit 8-33 WordAddrTest 8-44 writeICTRL 8-36 xprintf 8-45

xsprintf 8-45

overview 1-1 read cycle access time 4-3 receive clock (RCLK) 6-3 receive link (RLINK) 6-6 receive link clock (RLCLK) 6-6 receive serial (RSER) 6-4 receive sync (RSYNC) 6-4 references and manuals 1-6 register map for PCI9060ES 7-1 register monitor commands 8-10 registers

N non-burst cycles 4-4 notation conventions 1-6 number bases for monitor arguments . 8-6, 8-7 numeric format 8-6, 8-7 NVRAM default monitor configuration 8-2

BCR 4-3 BRGC 5-6 local configuration 7-1 PCI configuration 7-1 shared runtime 7-3 SICR 5-6 SIMODE 5-6 regulatory certifications 1-4 request signal, PCI 7-11 reset

P P11/P12 signal descriptions 7-10 parity error signal, PCI 7-11 PASS/FAIL power-up diagnostic flags . . 8-17 PCI9060ES. See PMC/PCI PLX Mailbox 0 power-up diagnostic flags 8-17 PMC/PCI

bandwidth 7-8 base address registers 7-2, 7-4, 7-5 bus interface 7-8 deadlocked cycle 7-6 direct slave cycles 7-6 EEPROM control register 7-4 initialization 7-3 interrupts 7-8, 7-10 local direct master cycles 7-6 overview 1-1, 7-1 PCI bridge 7-3 phantom read 7-7 register map 7-1 retry timers 7-7 power requirements 2-6 power-up

monitor sequence 8-1 PCI signal 7-11 returning boards 2-8 RISC controller 5-2 RJ-45 jack 6-9 RoHS 1-6

S S0-records 8-24 S1-S3 data records 8-25 S5 data records 8-25 S7-S9 termination and start address records 8-26 screen messages 8-28 SDMA channels 5-4 serial and version numbers 2-7 serial I/O

errors 8-29 monitor sequence 8-1 power-up diagnostics 8-4

baud rate 5-6 control from the monitor 8-43 overview 1-1 protocols 5-4 reference manuals 1-7 serial management controller (SMC) . . 5-5 serial number 2-7 SERR* 7-11 setup requirements 2-5 SICR register 5-6 SIMODE register 5-6 specifications

test commands 8-17 product ID 2-7 product repair 2-8 protection circuitry 6-1, 6-4 protocols

HDLC 5-4 UART 5-4

R RAM

dual port 5-3

10002367-02 PmT1 and PmE1 User’s Manual i-3

Page 126 of the Emerson Power Module (PME1) user manual — T T1 (DS2151Q)
Page 126 · click to enlarge
Page 126
Emerson Power Module (PME1) — T diagram (page 126)
Fig. 148

environmental 2-6 mechanical 2-1 power 2-6 S-records 8-18, 8-19, 8-24

TDM interface 6-1 table of contents ii-v tables, list of iv-xi target ready signal, PCI 7-11 technical references 1-6 technical support 6-7 terminology 1-6 time division multiplexor (TDM). . . 6-1 time slot assigner (TSA) 5-5 timers, general purpose 5-4 transmit clock (TCLK) 6-4 transmit link (TLINK) 6-6 transmit link clock (TLCLK) 6-6 transmit serial (TSER) 6-4 transmit sync (TSYNC) 6-4 troubleshooting, general 2-6

UL certifications 1-5 user-programmable machine (UPM) . . 4-3 utilities for the monitor 8-27

file example 8-26 start address record 8-22 start-up display, monitor 8-4 static control 2-1 stop signal, PCI 7-11 string format 8-6, 8-7 symbol format 8-6, 8-7 syntax for monitor commands 8-6, 8-7 system interface unit (SIU) 3-4 systems error signal, PCI 7-11

V vectors, interrupt 8-34 vendor ID 7-4 version

monitor 2-7 operating system 2-7 vi editing commands 8-5

W write cycle access time 4-3

T T1 (DS2151Q)

U UART 5-4

FDL 6-5 line impedance 6-4 overview 1-1

baud rate selection 5-6

PmT1 and PmE1 User’s Manual 10002367-02 i-4

Page 127 of the Emerson Power Module (PME1) user manual — T
Page 127 · click to enlarge
Page 127
Emerson Power Module (PME1) — T diagram (page 127)
Fig. 149
Show 28 more labels / short text on this page
____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________ · ____________________________________________________________________________________________
Page 128 of the Emerson Power Module (PME1) user manual — T
Page 128 · click to enlarge
Page 128
  • AC Power Systems
  • Connectivity
  • DC Power Systems
  • Embedded Computing
  • Embedded Power
  • Integrated Cabinet Solutions
  • Outside Plant
  • Power Switching & Controls
  • Precision Cooling
  • Services
  • Site Monitoring
  • Surge & Signal Protection

Emerson Network Power The global leader in enabling Business-Critical Continuity™

  • Emerson Network Power, Embedded Computing 8310 Excelsior Drive
  • Madison, WI 53717-1935 USA US Toll Free: 1-800-356-9602
  • Voice: +1-608-831-5500
  • FAX: 1-608-831-4249 Email: info@<a href="http://artesyncp.com" rel="nofollow noopener" target="_blank">artesyncp.com</a>

Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks andservice marks of

Emerson Network Power, Embedded Computing, Inc. © 2007 Emerson Network Power, Embedded Computing, Inc.

www.emersonembeddedcomputing.com

E M E R S O N. C O N S I D E R I T S O L V E D.™

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Emerson Power Module (PME1)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Emerson Power Module (PME1)

Be the first to ask — other owners or our team will answer.

Original document

Emerson Power Module (PME1) manual PDF

128 pages·3.9 MB·Network Router·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…