Instruction/ maintenance manual of the product DA-100 Emerson
Go to page of 7
SB-E-DA-100-A DA-100 LV M P AUT OMA TIC SPRA Y GUN OPERA TION MANUAL IMPORT ANT : Read and follow all instructions and SAFETY PRECAUTIONS before using this equipment. DESCRIPTION DA-100 L VMP gun is developed to achieve high transfer ef ficiency and it can be obt ained as well as high atomization with less air con sumption.
SAFTEY PRECAUSTIONS This manual contains important information that ALL users should know and und erstand BEF O RE using this equ ipment. This informa tion relates to USER SAFETY and PREVENTING EQUIPMENT PROBLEMS.
HAZARD CA USE SAFEGUARDS General Safety Improper operation or maintenance may create a hazard. Operators should be given adequate trai ning in the safe use and maintenance of the equipm ent (in accordance with the requireme nts of NFP A-33, Chapter 15 in U.
SPEC IFICA TION Max. Air Pressure: 0.69MPa (6.9 bar) Max. Fluid Pressure: 0.69MPa (6.9 bar) Cylinder Air Pressure: Min. 0.35MPa (3.5 bar) Max. 0.50MPa (5.0 bar) Weight: 480g Gun S tud Dia m eter: 16.0mm Fluid Thread: G1/4 (M) CAP Thre ad: G1/4 (M) CYL Threa d: G1/4 (M) INST ALLA TION Figure 1.
− 5 − CLEANING 1. Relieve air pressure from pre ssure tank. Carefully follow instructio ns in bulletin sent with ta nk. 2. Replace material in cont ainer with a suit able solvent. 3. Repressuri ze system. 4. T rigger gun and repeat proced ure until g un and hose are thoroughly clean.
Figure 5. Gun Exploded V iew Parts Sheet Ref No. Part Number Description Qty Remarks 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 JJ-6 JJ-50-K5 See Chart. 1 See Chart.
SERVICE C HECK Normal Spra y Pattern The proper combination of fluid pressure, fan and ato mizatio n air pressure, and fluid tip size should result in a p attern of this shape. PROBLEM CAUSE CORRECTION Will not spray . No pressure to gun. Piston stop s moving.
An important point after buying a device Emerson DA-100 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Emerson DA-100 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Emerson DA-100 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Emerson DA-100 you will learn all the available features of the product, as well as information on its operation. The information that you get Emerson DA-100 will certainly help you make a decision on the purchase.
If you already are a holder of Emerson DA-100, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Emerson DA-100.
However, one of the most important roles played by the user manual is to help in solving problems with Emerson DA-100. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Emerson DA-100 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center