Model No. CF2000AB02 CF2000PW02 CF2000AW02 CF2000WB02 CF2000BC02 CF2000WW02 CF2000ORB02
DATE CODE:
Max. Weight: 26.0 Lbs.
The date code of this fan may be found on the box, stamped in ink on a white label.
You should record this data above and keep it in a safe place for future use.
Part No. F40BP73230001 Form No. BP7323-1 U.L. Model No.: CF2000
With Blades



This Manual Is Designed to Make it as Easy as Possible for You to
Installed Wire Length Wire Size A.W.G. Up to 50 ft. 14 50-100 ft. 12
One Phillips head screwdriver One stepladder Five wire connectors (supplied) One wire stripper
MATERIALS Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following size:
Before assembling your ceiling fan, refer to section on proper method of wiring your fan (page 6). If you feel you do not have enough wiring knowledge or experi- ence, have your fan installed by a licensed electrician.
a. Fan motor and housing assembly b. One motor cover c. One ceiling cover d. Five blade flanges e. One hanger ball/downrod assembly f. One hanger bracket g. One switch housing cover h. One loose parts bag containing:
LOOSE PARTS BAG
HANGER BRACKET
BLADE FLANGES
CEILING COVER
SWITCH HOUSING COVER

4. Install the setscrew (supplied) in the motor coupling (Figure 2). While pulling up on the hanger ball, tighten the setscrew using the setscrew wrench (supplied). NOTE: The setscrew must be properly installed as described above, or fan wobble could result. 5.Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 3). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 8.
HANGER BALL/ DOWNROD ASSEMBLY
MOTOR COUPLING FAN MOTOR AND HOUSING ASSEMBLY
PIN
HANGER BALL
DOWNROD SETSCREW
Figure 1 Figure 3
It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed (as shown in Figure 2) could result in the fan falling.
3. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 2). (Pin and clip are supplied in loose parts bag.) The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the hanger ball to make sure the clevis pin is properly installed.
LOCKWASHER
MOTOR COVER
1" THREADED STU 7/8"
MOTOR
DOWNROD
HANGER BALL
SETSCREW
MOTOR COUPLING
CLEVIS PIN
PIN
WHITE LEAD
CONNECTED BROWN LEADS
HANGER BALL
CLEVIS PIN HAIRPIN CLIP
DOWNROD
MOTOR COUPLING
CONNECTED RED LEADS
SETSCREW
Figure 5 Figure 2

8.Reinstall the hanger ball on the downrod (Figure 5) as follows. Route the motor leads through the hanger ball and slide the hanger ball over the downrod. Install the pin through the holes at the top of the downrod and slide the hanger ball up the downrod, aligning the ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.
AT LEAST
The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support”.
It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
TAB
If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.
Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.
Turning off wall switch is not sufficient. To avoid pos- sible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with national and local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
How to Hang Your
HANGER BRACKET
Ceiling Fan
HANGER BALL/ DOWNROD ASSEMBLY Figure 3
The fan must be hung with at least 7' of clearance from floor to blades (Figure 6).
To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and the hanger bracket.
7' · FLOOR Figure 6

Ceiling Fan
If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.
switch.
To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. NOTE: If you are not sure if the outlet box is ground- ed, contact a licensed electrician for advice, as it must be grounded for safe operation.
BLACK AND BLUE FAN WIRES
1-1/4" THREADED STUD
GROUND WIRE
CEILING COVER LOCKWASHER
LISTED WIRE CONNECTOR (3)
WHITE SUPPLY (NEUTRAL)
KNURLED KNOB
GREEN WIRE (GROUND) FROM HANGER BRACKET
To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.
GREEN WIRE (GROUND) FROM HANGER BALL
BLACK SUPPLY (HOT)
Installing Fan Blades
10-32 x 3/8" PAN HEAD SCREW
2. Securely connect the fan motor white wire to the supply white (neutral) wire using wire connector supplied (Figure 9). Securely connect the fan motor black wire and blue wire to the supply black (hot) wire using wire connector supplied (Figure 9). After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box.
FAN BLADE
BLADE FLANGE Figure 11
Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.

THREE-SPEED
SWITCH
1st Pull—HIGH 2nd Pull—Medium 3rd Pull—Low 4th Pull—OFF
SPEED CONTROL PULL CHAIN SWITCH
10-32 x 5/8" OVAL HEAD SCREW (2 Per Blade Assembly) Figure 12
To reduce the risk of personal injury, do not bend the blade flanges when installing the flanges, balancing the blades, or cleaning the fan. Do not insert foreign objects between rotating fan blades.
To install an accessory light kit, remove the two screws securing the switch housing cover to the switch housing. Remove the screw plug from the bot- tom of the switch housing cover and install the light kit in accordance with the light kit Owner's Manual.
To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring.
for your Ceiling Fan
Periodic cleaning of your new ceiling fan is the only maintenance that is needed.
When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish.
Abrasive cleaning agents are not required and should be avoided to prevent damage to finish.
SWITCH HOUSING COVER PULL CHAIN 8-32 x 3/8" SCREW
Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock.

Before discarding packaging material, be certain
all parts have been removed.
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION:
The use of any other control not specifically approved for this fan could result in fire, shock and personal injury.
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric, Co. Substitution of parts or acces- sories not designated for use with this product by Emerson Electric, Co. could result in personal injury or property damage.
!



*Fan blade assemblies are purchased separately.

What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is: As it applies to the motor, this warranty will last for the lifetime of your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
How State Law Relates To The Warranty: Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Air Comfort Products DIVISION OF EMERSON ELECTRIC, CO. 8100 W. Florissant ¥ St. Louis, MO 63136
Printed in China 03/07 Part No. F40BP73230001 Form No BP7323-1
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| 1. Fan will not start. | 1. Fuse or circuit breaker blown. 2. Loose power line connections to the fan, or loose switch wire connections in the switch housing. | 1. Check main and branch circuit fuses or circuit breakers. ! WARNING: Make sure main power is turned off. 2. Check line wire connections to fan and switch wire connections in the switch housing. | p.8 |
| 2. Fan sounds noisy. | 1. Blades not attached to fan. 2. Loose screws in motor housing. 3. Screws securing fan blade flanges to motor hub are loose. 4. Wire connectors inside switch housing rattling. 5 Screws holding blades to flanges are loose. | 1. Attach blades to fan before operating. 2. Check to make sure all screws in motor housing are snug (not over-tight). 3. Check to make sure the screws which attach the fan flanges to the motor hub are tight. ! WARNING: Make sure main power is turned off. 4. Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing. 5. Tighten screws securely. | p.8 |
| 3. Fan wobbles excessively. | 1. Setscrew in motor coupling is loose. 2. Setscrew in hanger ball/downrod assembly is loose. 3. Screws securing fan blade flanges to motor hub are loose. 4. Fan blade flanges not seated properly. 5. Hanger bracket and/or ceiling outlet box is not securely fastened. 6. Fan blades out of balance. | 1. Raise motor cover and tighten setscrew securely. 2. Tighten the setscrew in the hanger ball/downrod assembly. 3. Check to be sure screws which attach the fan blade flanges to the motor hub are tight. 4. Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor hub. If flanges are seated incorrectly, loosen the flange screws and retighten according to step 3 in the section “Installing Fan Blades”. 5. Tighten the hanger bracket screws to the outlet box, and/or secure outlet box. 6. Interchanging an adjacent (side-by-side) blade pair can redistribute the weight and result in smoother operation. Or use supplied balancing kit to balance blades. | p.8 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.