EN
ULINE logo
Official user manual

ULINE Dehumidifiers

21 pages·369 KB·Household Appliance·PDF·ENDEITNLJA
ULINE Dehumidifiers
Table of Contents 24 sections H-8554, H-8555 DEHUMIDIFIERS · 1-800-295-5510 uline.com · SAFETY · NOTE: Before installing and using dehumidifier, · … ShowHide
Page 1 of the ULINE Dehumidifiers user manual — NOTE: There may be a small amount of water
Page 1 · click to enlarge
Page 1

Para Español, vea páginas 8-14. Pour le français, consulter les pages 15-21.

H-8554, H-8555 DEHUMIDIFIERS

1-800-295-5510 uline.com

SAFETY

NOTE: Before installing and using dehumidifier,

  • Emptying the bucket depends on how many pints of moisture the dehumidifier removes from the air. The number of times the bucket will be emptied depends on the unit's model number. Emptying should be completed at full capacity.

read these instructions carefully. Store in a safe place for future reference.

  • Always place unit on a level surface.
  • Never use or store gasoline or other flammable vapor or liquid near unit.
24-HOUR PERIOD MODEL #MOISTURE TO REMOVE (DOE RATING)TIMES TO EMPTY H-855435 Pints4 H-855550 Pints3
  • Maintain 12-18" clearance around unit. Do not block or cover air inlet or outlet grilles.
  • Unit must be connected to a correctly grounded power supply.
  • Do not start or stop unit by inserting or pulling out power plug.
  • Using a dehumidifier will balance the humidity level in the room, creating a more comfortable space. Over time, this humidity level stabilizes, resulting in less moisture accumulating in the air. As moisture level decreases, dehumidifier will not need to collect as much moisture as seen in previous operation.
  • Do not use an adapter plug or extension cord.
  • Do not use near a bathtub, shower or swimming pool.
  • Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grilles.

NOTE: Do not be concerned if the dehumidifier

is removing less moisture from the air or the bucket is taking longer to fill. The dehumidifier is working as intended and creating a more stable humidity level.

  • Do not let children play near unit.
  • Always inspect cord for signs of damage before use. If power cord is damaged, it must be replaced by manufacturer or a qualified service technician.

NOTE: There may be a small amount of water

present in the bucket before using dehumidifier for the first time. This is caused by preliminary factory testing.

  • When cleaning, always turn unit off and unplug the power cord.
  • Recommended humidity levels: Spring/Summer: 35% – 45% Fall/Winter: 45% – 55%
  • During normal operation, dehumidifier will exhaust warm air from top of unit.
Page 2 of the ULINE Dehumidifiers user manual — FEATURES
Page 2 · click to enlarge
Page 2

FEATURES

Removes up to 35 or 50 pints (depending on model) of moisture from the air every 24 hours. This is not the bucket size. Adjustable humidistat for precise humidity control. Mirage display shows ambient humidity level from across the room. Operates at temperatures down to 41°F. Automatic defrost function melts away ice from frozen coils. Three-speed fan allows user to select between maximum dehumidifying power or quiet operation. Bucket full indicator and audible alarm signals when bucket is full and ready to be emptied. Ultra quiet operation allows for use almost anywhere. Loss of power protection remembers settings when power is interrupted. Auto-restart automatically continues operation when power is restored. No need to manually restart the dehumidifier. 24-hour timer automatically turns on and off the unit after the preset time of 0.5 up to 24 hours. MyHome modes allow user to choose where dehumidifier is operating (Sleeping Space – 55%, Living Space – 50% or Basement – 45%).
Page 3 of the ULINE Dehumidifiers user manual — OPERATION
Page 3 · click to enlarge
Page 3

CONTROL PANEL

Child-Lock LED Indicator Digital Humidistat

Bucket Full LED Indicator

Power On LED Indicator

Clean Filter LED Indicator

Fan Speed LED Indicators

ULINE Dehumidifiers — CONTROL PANEL diagram (page 3)
Fig. 1

OPERATION

5. Timer Auto On – To program unit to automatically turn on, press the Timer button when unit is off. Press or to increase or decrease the timer in 30-minute increments up to 10 hours. After 10 hours, each press of the or buttons will increase timer in one-hour increments up to 24 hours. Once desired time is reached, unit will automatically turn on.
1. When first operating dehumidifier, run Continuous mode for 24 hours.
2. Power On and Off – Press the power button once to manually turn on unit. Press the power button once more to turn off unit.
6. Timer Auto Shut-Off – To program unit to automatically turn off, press the timer button when unit is on. Each press of the or buttons will change the timer setting in 30-minute increments up to 10 hours. After 10 hours, each press of the or buttons will increase or decrease timer in one-hour increments up to 24 hours. Once desired time is over, unit will automatically power off.

3. Humidity Selection – Press the or buttons to choose desired humidity in the room. Each button press will change desired room humidity by 5%. The room humidity is selectable from 35-80% or continuous. Unit will cycle on and off to maintain chosen humidity level. If dehumidifier is to operate continuously regardless of room humidity, press the mode button until "CO" is displayed. This will enable continuous operation and the continuous indicator will light up on the control panel.

7. MyHome Modes – Preset humidity level settings allow user to easily move dehumidifier from room to room and select the corresponding mode for location in which dehumidifier is operating. Press mode button to choose from sleeping space (55%), living space (50%) or basement (45%).
4. Fan Speed Control – Press the fan speed button to cycle through different fan speeds: quiet, high and low. Fan speed can be visually distinguished by the fan speed indicators on control panel. For fast dehumidification, choose high. For moderate dehumidification, choose low. For quiet operation, choose quiet.
8. Child-Lock Mode – To lock control panel, press and hold the timer button for three seconds. Locking the control panel prevents someone from accidentally changing settings. When locked, the lock indicator will light up. Press and hold the timer button for three seconds to unlock control panel.
Show 13 more labels / short text on this page
Power Button · Display · MyHome Mode · Timer LED Indicator · LED Indicators · Mirage Display Button · Filter Button · Fan Speed · Button Humidity Selection · Preset Mode · Timer Button · Button · Button
Page 4 of the ULINE Dehumidifiers user manual — LOCATION
Page 4 · click to enlarge
Page 4

OPERATION CONTINUED

9. Mirage Display – Backlit display on the front of dehumidifier, which shows the actual humidity level in room. Press the mirage button to turn on mirage display and once again to turn off mirage display.
  • Allow at least 18" of air flow on all sides. (See Figure 2)
ULINE Dehumidifiers — OPERATION CONTINUED diagram (page 4)
Fig. 2
  • Place in an area where temperature will not fall below 41°F. Coils can become covered with frost at temperatures below 41°F, which may reduce performance.

NOTE: Fan will continue to run when compressor

is off. This allows unit to circulate air and operate more efficiently.

10. Bucket Full – When water bucket is full, unit will automatically shut off, beep and bucket full indicator will light up. Unit will not function until water bucket is emptied and placed back into unit. Bucket should be cleaned every few weeks to prevent growth of mold, mildew and bacteria. Use a mild detergent to clean bucket. Once clean, completely dry bucket and replace in unit.
  • Use in areas that have excessive moisture such as entryways, bathrooms, basements and laundry rooms.
  • Use to prevent moisture damage anywhere books or valuables are stored.

NOTE: Hold bucket with both hands when emptying. (See Figure 1)

  • Use the dehumidifier in a basement to help prevent moisture damage.
ULINE Dehumidifiers — NOTE: Hold bucket with both hands when emptying. (See Figure 1) diagram (page 4)
Fig. 3 · NOTE: Hold bucket with both hands when emptying. (Se…
  • Operate in an enclosed area to be most effective.

AUTOMATIC DEFROST

When frost builds up on evaporator coils, compressor will cycle off and fan will continue to run until frost disappears. When coils are completely defrosted, compressor will automatically restart and dehumidification will begin.

CONTINUOUS DRAINAGE

GARDEN HOSE INSTALLATION AND SETUP

from dehumidifier, compressor will turn off, but fan may continue to run for a few minutes. Dehumidifier will not be removing moisture from the air at this time. When removing moisture from the air, dehumidifier will exhaust warm air from top exhaust vent. Do not place a full bucket on floor because bottom of bucket is uneven.

Attach a garden hose (not included) to continuous drainage port on back of dehumidifier. This will allow unit to run continuously (depending on selected humidity level) without having to empty water bucket.

1. Place on a level surface.
2. Unscrew cap on back of unit to access hose nozzle.
3. Thread garden hose onto accessible nozzle, lead to a floor drain and cut to length.

LOCATION

A dehumidifier operating in a basement will have little or

4. Ensure no kinks or knots are in hose.

no effect on drying an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area.

5. Turn on unit. Press mode button until set to continuous.
  • Do not use outdoors. For indoor use only.
  • Place on a smooth, level surface strong enough to support unit with full bucket of water.
Page 5 of the ULINE Dehumidifiers user manual — TROUBLESHOOTING
Page 5 · click to enlarge
Page 5

MAINTENANCE

Press the filter button to reset clean filter indicator.

CLEANING UNIT HOUSING

CLEANING/REPLACING FILTER

1. Keep away from direct sunlight to prevent color fading.
2. Clean surface with a damp cloth and dry with a soft towel.

The clean filter indicator will illuminate every 250 hours of operation as a reminder to clean the filter. A clean filter will keep unit operating at optimum performance.

STORING/TRANSPORTING

1. Turn off dehumidifier.
ULINE Dehumidifiers — STORING/TRANSPORTING diagram (page 5)
Fig. 4
2. Unplug unit and secure power cord to back of unit.
3. Clean or replace filter (see information at left).
4. Empty water in bucket and rinse bucket with a mild detergent. Dry bucket.
5. Insert empty water bucket back into dehumidifier.
6. Unit is ready for storage or transportation.
7. Store in a cool, dry place.
1. To access filter, lift air inlet grille. (See Figure 3) 2. Remove filter from back of unit using thumbs to press down on filter tabs directly above filter.

NOTE: While in Pump Mode, if unit is turned off,

pump will remove remaining water from bucket prior to unit completely powering down. Pump indicator light will stay on during this period. Do not unplug the power cord until pump indicator light is off.

3. Clean filter with warm, soapy water. Dry thoroughly before replacing filter.
4. Once filter is completely dry, place back into unit.

TROUBLESHOOTING

OPERATING ISSUECAUSESRECOMMENDATIONS Dehumidifier does not start.Dehumidifier is unplugged. Fuse is blown/circuit breaker is tripped. Dehumidifier has reached its present level or the bucket is full. Bucket is not installed properly. Power failure.Ensure power cord is pushed completely into outlet. Check house fuse/circuit breaker box and replace fuse or reset breaker. Dehumidifier automatically turns off when either condition occurs. Change to a lower setting or empty the water bucket and replace properly. Bucket must be in place and securely seated for dehumidifier to operate. A protective time delay (up to three minutes) prevents tripping of the compressor overload. For this reason, the unit may not start normal dehumidification for three minutes after powered back on.
Page 6 of the ULINE Dehumidifiers user manual — TROUBLESHOOTING CONTINUED
Page 6 · click to enlarge
Page 6

TROUBLESHOOTING CONTINUED

OPERATING ISSUECAUSESRECOMMENDATIONS Dehumidifier does not remove adequate moisture from the air.Not enough time allowed for unit to remove moisture.When first installed, allow at least 24 hours to maintain the desired dryness. Airflow is restricted.Ensure there are no curtains, blinds or furniture blocking front or back of unit. See the Location section on Page 4. Dirty filter.See Cleaning/Replacing Filter on Page 5. Humidity Control may not be set low enough.For drier air, press the button to lower the percent humidity desired in the room, or set the dehumidifier to "CO" for maximum dehumidification. Doors and windows may not be closed tightly.Check that all doors, windows and other openings are securely closed. Clothes dryer may be blowing moist air into the room.Install dehumidifier away from dryer. Dryer should be vented outside. Room temperature is too low.Moisture removal is best at higher room temperatures. Lower room temperatures will reduce the moisture removal rate. This model is designed to operate at temperatures above 41°F. Dehumidifier runs too much.Area to be dehumidified is too large.Capacity of dehumidifier may not be adequate for room size or amount of moisture in air. Doors and windows are open.Close all doors and windows to the outside. Frost appears on coils.Dehumidifier has recently been turned on or room temperature is below 41°F.This is normal. Frost will usually disappear within 60 minutes. Controls cannot be set.The compressor will turn off and fan will automatically continue to run for approximately three minutes at a fixed setting.This is normal. Wait approximately three minutes and set fan speed to desired level. Fan noiseAir is moving through unit.This is normal. Water on the floorHose connection may be loose.Check the hose connection. See Continuous Drainage/Garden Hose Installation and Setup on Page 4. Hose is attached but not draining into a drain.Disconnect hose if using bucket or place hose near a drain.
Page 7 of the ULINE Dehumidifiers user manual — 1-800-295-5510 uline.com
Page 7 · click to enlarge
Page 7

TROUBLESHOOTING CONTINUED

OPERATING ISSUECAUSESRECOMMENDATIONS Unit will not turn on.Fuse is blown/circuit breaker is tripped.Check house fuse/circuit breaker box and replace fuse or reset breaker. Unit is on but fan is not running.Dehumidifier has reached its present level or bucket is full.Dehumidifier automatically turns off when either condition occurs. Change to a lower setting or empty water bucket and replace properly. Bucket is not in proper position.Bucket must be in place and securely seated for dehumidifier to operate. Power failure.A protective time delay (up to three minutes) prevents tripping of compressor overload. For this reason, the unit may not start normal dehumidification for three minutes after it is powered back on. Continuous Mode is on, but water is draining in bucket.Incorrect drain hose is installed.Garden hose must be used while operating in Continuous Mode. Dehumidifier on uneven surface.Ensure unit is placed on a flat, level surface.

If the troubleshooting section does not resolve the problem, contact Uline Customer Service at 1-800-295-5510.

SELF-DIAGNOSING CODES

SELF-DIAGNOSING CODEDESCRIPTIONRECOMMENDATION E1Compressor Overheat ProtectionContact Uline Customer Service at 1-800-295-5510. E2Condenser Overheat Protection EHHumidity Sensor Malfunction

1-800-295-5510 uline.com

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Dehumidifier does not start.Dehumidifier is unplugged. Fuse is blown/circuit breaker is tripped. Dehumidifier has reached its present level or the bucket is full. Bucket is not installed properly. Power failure. p.5
Dehumidifier does not start. p.5
Dehumidifier does not remove adequate moisture from the air.Not enough time allowed for unit to remove moisture. p.6
Dehumidifier does not remove adequate moisture from the air.Airflow is restricted. p.6
Dehumidifier does not remove adequate moisture from the air.Dirty filter. p.6
Dehumidifier does not remove adequate moisture from the air.Humidity Control may not be set low enough. p.6
Dehumidifier does not remove adequate moisture from the air.Doors and windows may not be closed tightly. p.6
Dehumidifier does not remove adequate moisture from the air.Clothes dryer may be blowing moist air into the room. p.6
Dehumidifier does not remove adequate moisture from the air.Room temperature is too low. p.6
Dehumidifier runs too much.Area to be dehumidified is too large. p.6
Dehumidifier runs too much.Doors and windows are open. p.6
Frost appears on coils.Dehumidifier has recently been turned on or room temperature is below 41°F. p.6
Controls cannot be set.The compressor will turn off and fan will automatically continue to run for approximately three minutes at a fixed setting. p.6
Fan noiseAir is moving through unit. p.6
Water on the floorHose connection may be loose. p.6
Water on the floorHose is attached but not draining into a drain. p.6
Unit will not turn on.Fuse is blown/circuit breaker is tripped. p.7
Unit is on but fan is not running.Dehumidifier has reached its present level or bucket is full. p.7
Unit is on but fan is not running.Bucket is not in proper position. p.7
Unit is on but fan is not running.Power failure. p.7
Continuous Mode is on, but water is draining in bucket.Incorrect drain hose is installed. p.7
Continuous Mode is on, but water is draining in bucket.Dehumidifier on uneven surface. p.7

Ask about the ULINE Dehumidifiers

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the ULINE Dehumidifiers

Be the first to ask — other owners or our team will answer.

Original document

ULINE Dehumidifiers manual PDF

21 pages·369 KB·Household Appliance·PDF
Click any page above to open it here
Page 1 / …
100%