Para Español, vea páginas 8-14. Pour le français, consulter les pages 15-21.
SAFETY
read these instructions carefully. Store in a safe place for future reference.
is removing less moisture from the air or the bucket is taking longer to fill. The dehumidifier is working as intended and creating a more stable humidity level.
present in the bucket before using dehumidifier for the first time. This is caused by preliminary factory testing.


Child-Lock LED Indicator Digital Humidistat
Bucket Full LED Indicator
Power On LED Indicator
Clean Filter LED Indicator
Fan Speed LED Indicators

3. Humidity Selection – Press the or buttons to choose desired humidity in the room. Each button press will change desired room humidity by 5%. The room humidity is selectable from 35-80% or continuous. Unit will cycle on and off to maintain chosen humidity level. If dehumidifier is to operate continuously regardless of room humidity, press the mode button until "CO" is displayed. This will enable continuous operation and the continuous indicator will light up on the control panel.


is off. This allows unit to circulate air and operate more efficiently.

When frost builds up on evaporator coils, compressor will cycle off and fan will continue to run until frost disappears. When coils are completely defrosted, compressor will automatically restart and dehumidification will begin.
from dehumidifier, compressor will turn off, but fan may continue to run for a few minutes. Dehumidifier will not be removing moisture from the air at this time. When removing moisture from the air, dehumidifier will exhaust warm air from top exhaust vent. Do not place a full bucket on floor because bottom of bucket is uneven.
Attach a garden hose (not included) to continuous drainage port on back of dehumidifier. This will allow unit to run continuously (depending on selected humidity level) without having to empty water bucket.
A dehumidifier operating in a basement will have little or
no effect on drying an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area.

Press the filter button to reset clean filter indicator.
CLEANING/REPLACING FILTER
The clean filter indicator will illuminate every 250 hours of operation as a reminder to clean the filter. A clean filter will keep unit operating at optimum performance.

pump will remove remaining water from bucket prior to unit completely powering down. Pump indicator light will stay on during this period. Do not unplug the power cord until pump indicator light is off.


If the troubleshooting section does not resolve the problem, contact Uline Customer Service at 1-800-295-5510.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Dehumidifier does not start. | Dehumidifier is unplugged. Fuse is blown/circuit breaker is tripped. Dehumidifier has reached its present level or the bucket is full. Bucket is not installed properly. Power failure. | p.5 | |
| Dehumidifier does not start. | p.5 | ||
| Dehumidifier does not remove adequate moisture from the air. | Not enough time allowed for unit to remove moisture. | p.6 | |
| Dehumidifier does not remove adequate moisture from the air. | Airflow is restricted. | p.6 | |
| Dehumidifier does not remove adequate moisture from the air. | Dirty filter. | p.6 | |
| Dehumidifier does not remove adequate moisture from the air. | Humidity Control may not be set low enough. | p.6 | |
| Dehumidifier does not remove adequate moisture from the air. | Doors and windows may not be closed tightly. | p.6 | |
| Dehumidifier does not remove adequate moisture from the air. | Clothes dryer may be blowing moist air into the room. | p.6 | |
| Dehumidifier does not remove adequate moisture from the air. | Room temperature is too low. | p.6 | |
| Dehumidifier runs too much. | Area to be dehumidified is too large. | p.6 | |
| Dehumidifier runs too much. | Doors and windows are open. | p.6 | |
| Frost appears on coils. | Dehumidifier has recently been turned on or room temperature is below 41°F. | p.6 | |
| Controls cannot be set. | The compressor will turn off and fan will automatically continue to run for approximately three minutes at a fixed setting. | p.6 | |
| Fan noise | Air is moving through unit. | p.6 | |
| Water on the floor | Hose connection may be loose. | p.6 | |
| Water on the floor | Hose is attached but not draining into a drain. | p.6 | |
| Unit will not turn on. | Fuse is blown/circuit breaker is tripped. | p.7 | |
| Unit is on but fan is not running. | Dehumidifier has reached its present level or bucket is full. | p.7 | |
| Unit is on but fan is not running. | Bucket is not in proper position. | p.7 | |
| Unit is on but fan is not running. | Power failure. | p.7 | |
| Continuous Mode is on, but water is draining in bucket. | Incorrect drain hose is installed. | p.7 | |
| Continuous Mode is on, but water is draining in bucket. | Dehumidifier on uneven surface. | p.7 |