PERISTYLE ™
Ceiling Fan Owner's Manual
Model Numbers CF100AP00 Antique Pewter with Natural
CF100DBK00
Distressed Black with Distressed Black/Natural
Golden Espresso with Teak/Golden Espresso Blades
Net Weight: 30.0 Lbs.
Part No. F40BP73550001 Form No. BP7355-1 U.L. Model No.: CF100
Cherry/Mahogany Blades

Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, secure- ly fasten a warning device, such as a tag, to the service panel. 3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing. 4. Do not put anything into the fan blades while they are turning. 5. Do not operate reversing switch until fan blades have come to a complete stop. Additional Safety Instructions for Installation 1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades. 2. The installation is to be in accordance with the National Electrical Code, ANSI/NFPA 70-1999 and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician. 3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a quali- fied electrician if in doubt. 4. The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling. 5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades. 6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician. NOTE: This fan is suitable for use with solid-state speed controls. WARNING: To reduce the risk of fire or electric shock, this fan should only be used with fan speed control Model No. UC7067RC, manufactured by Rhine Electric Co., Ltd. WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage. WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades. WARNING: To reduce the risk of electrical shock, this fan must be installed with an isolating wall control/switch.
DATE CODE: The date code of this fan may be found on the box, stamped in ink on a white label. You should record this data above and keep it in a safe place for future use.

This Manual Is Designed to Make it as Easy as Possible for You to
Tools Needed for Assembly One Phillips head screwdriver One wire stripper One stepladder Three 60-watt (max.) candelabra base bulbs Six wire connectors (supplied)
Materials Wiring, outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following sizes:
a. Fan motor and housing assembly b. One ceiling cover c. Once coupling cover d. Five fan blades e. Five blade flanges f. One hanger bracket g. One hanger ball/downrod assembly h. One switch housing/light fitter assembly i. One lower ring assembly (includes four mounting screws) j. One lower glass k. One remote control transmitter l. One remote control receiver m. One loose parts bag containing:
Installed Wire Length Wire Size A.W.G. Up to 50 ft. 14 50-100 ft. 12
Unpacking Instructions For your convenience, check-off boxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.
Do not install or use fan if any part is damaged or missing. Call Toll-Free:
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
D
H
E
B
F
J
FAN/OFF
FOR/REV
HI
MED
® L M G
LIGHT DIMMER
LOW
K

Your remote control receiver is equipped with a preset memory feature. The receiv- er will remember the light intensity and fan speed when the light and fan are turned off from the wall switch. When the wall switch is turned back on, the lights and fan will resume operation as they were prior to the switch being turned off.
Your Emerson ceiling fan comes equipped with a remote control transmitter and a remote control receiver. This remote con- trol systems is designed to control your ceiling fan speed, airflow direction, and light intensity. NOTE: An optional SW113 Wall Control (not supplied) may also be used with the remote control receiver supplied with your ceiling fan.
This Owner’s Manual is divided into two sections. The first section, REMOTE CONTROL PROCEDURES, describes how to install the 9-volt alka- line battery (not supplied) in the remote control transmitter, and how to set the operating frequency of the transmitter and receiver. These instructions must be performed prior to the installation of the ceiling fan as described in the second section, CEILING FAN PROCE- DURES.
SWITCH LEVERS
ON
1 2 3 4
BATTERY
CODE SWITCH
REMOTE CONTROL TRANSMITTER
ON
4 3 2 1
REMOTE CONTROL
Setting Operating Frequency of Transmitter
PROCEDURES
and Receiver
General
Your remote control transmitter and receiver have code switches which must be set on one of 16 possible code combi- nations. The four levers (numbered 1, 2, 3, and 4) on the switches are factory-set in the ON (up) position. Do not use this setting. Change the switch settings as follows: 1. On the remote control transmitter, locate the code switch just above the battery compartment (Figure 1).
The remote control system is designed to separately control your ceiling fan and light intensity. There are four push buttons on the transmitter (HI, MED, LOW, OFF) to set the fan speed and turn the fan off. The FOR/REV push button changes the airflow direction of the fan blades. The LIGHT DIMMER push button turns the lights on and off and controls the light intensity. The red indicator light will illuminate while any button is pressed, indicating that the bat- tery is good. 4

2. Slide the four switch levers on the code switch to your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down. 3. In the receiver (Figure 1), slide the four switch levers to the same positions as set in the transmitter. Make sure the levers on both switches are in the same positions, otherwise the fan will not operate. 4. Position the battery in the transmitter battery compartment and replace the battery cover.
Turning off wall switch is not suffi- cient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceil- ing fan must be properly grounded as a precaution against possible electri- cal shock.
Ceiling Fan
Electrical Requirements
Your new ceiling fan will require a ground- ed electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
HANGER BALL
SETSCREW DOWNROD
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws sup- plied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electri- cian if in doubt.
2. Unscrew the setscrew (Figure 3) until it clears the inside of the motor coupling. Then separate, untwist and unkink the three 80” motor leads. Route the motor lead wires through the downrod. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hair- pin clip (Figure 3). The clevis pin must go through the holes in the motor cou- pling and the holes in the downrod. Be sure to push the straight leg of the hair- pin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull up on the downrod to make sure the clevis pin is properly installed.
To avoid possible fire or shock, fol- low all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician.
If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the exist- ing light fixture.

5. Reinstall the hanger ball (Figure 5) on the downrod as follows. Route the three 80” motor leads through the hanger ball and slide the hanger ball over the downrod. Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.
It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tight- ened. Failure to verify that the pin and setscrews are properly installed (as shown in Figure 3) could result in the fan falling.
DOWNROD
It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
SETSCREWS MOTOR COUPLING Figure 3
PIN
DOWNROD
SETSCREW
COUPLING COVER
To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balanc- ing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

10-24 x 9mm TRUSS HEAD SCREW (3)
FAN BLADE
BLADE FLANGE
MOTOR CONNECTOR
SWITCH HOUSING CONNECTOR SWITCH HOUSING PLATE
8-32 x 7mm PAN HEAD SCREW (2)
12. Partially install two 8-32 x 7mm pan head screws (supplied) into two of the threaded holes in the side of the switch housing plate (Figure 8). 13. Position the two slots in the switch housing/light fitter assembly over the two 8-32 x 7mm screws (Figure 9). Turn the switch housing assembly clockwise and tighten the two screws. Install another 8-32 x 7mm pan head screw into the remaining hole to secure the switch housing assembly. NOTE: Do not pinch wires between the switch housing assembly and the switch housing plate.
SLOT FOR FLANGE SCREW ACCESS
INSTALL 8-32 x 7mm PAN HEAD SCREW
TIGHTEN TWO 8-32 x 7mm PAN HEAD SCREWS
MOTOR HUB
1/4-20 x 11mm PAN HEAD SCREWS WITH LOCKWASHER (2)

Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.
The fan must be hung with at least 7' of clearance from floor to blades (Figure 10).
TWO SCREWS SUPPLIED WITH OUTLET BOX
CEILING
HANGER BRACKET
TAB
AT LEAST
The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support”.
Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws sup- plied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electri- cian if in doubt.
HANGER BRACKET HANGER BALL/ DOWNROD ASSEMBLY
To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket.
7' · FLOOR Figure 10

is visible at the wire connectors, except for the ground wire.
If you feel that you do not have enough electrical wiring knowledge or experi- ence, have your fan installed by a licensed electrician.
wires from the hanger ball and the hanger bracket to the supply grounding conductor (this may be a bare wire or a wire with green insulation). b. Securely connect the supply white
Turning off wall switch is not suffi- cient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accor- dance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
(neutral) wire to the receiver white (AC IN N) wire. c. Securely connect the supply black wire
(hot) wire to the receiver black (AC IN L) wire. d. Securely connect the fan motor white
wire to the receiver white (TO MOTOR N) wire. e. Securely connect the fan motor black
wire to the receiver black (TO MOTOR L) wire. f. Securely connect the fan motor blue
wire to the receiver blue (FOR LIGHT) wire.
Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire con- nectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.
RECEIVER BLACK WIRE
AC
N
N
SUPPLY BLACK WIRE (HOT) GROUND WIRE
RECEIVER BLACK WIRE
RECEIVER BLUE WIRE
TO MOTOR L
GREEN GROUND WIRE FROM HANGER BALL
AC IN L
TO MOTOR N
FOR LIGHT
FAN BLACK WIRE ANTENNA
GREEN GROUND WIRE FROM HANGER BRACKET
FAN BLUE WIRE
1-1/4" THREADED STUD (2)
RECEIVER WHITE WIRE FAN WHITE WIRE

WALL CONTROL
BLACK
BLACK
TO 120VOLT SUPPLY
(HOT)
BLACK
WHITE
WHITE
WHITE
GROUND
BLACK
TWO-CONDUCTOR
WHITE BLUE
CABLE (WITH
GROUND)
BLACK
GREEN WIRE (GROUND) FROM HANGER BALL AND
BLUE
WHITE
HANGER BRACKET
HANGER BALL
To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.
60-WATT CANDELABRA BASE BULB (3)
CEILING COVER
LOWER RING BRACKET
SOCKET
THREADED STUD (2)
LOCKWASHER (2)
POST
LOWER RING ASSEMBLY
KNURLED KNOB (2)
LOWER GLASS

Ceiling Fan
IMPORTANT Fan installation must be completed, including the installation of the fan blades, before testing of the remote control. Your remote control has full control of your fan and light. 1. Restore electrical power to the outlet box by turning the electricity on at the service panel. 2. To set the desired fan speed, press the HI, MED, or LOW buttons to operate your fan on high, medium, or low speed (Figure 18). 3. To turn your fan off, press the FAN/OFF button. 4. To change the airflow direction of the fan blades, press the FOR/REV button. The direction the fan blades turn will change each time the FOR/REV button is pressed. 5. To set the level of light brightness, press and hold the LIGHT DIMMER button. The light brightness will contin- ue to increase then decrease while the button is held down. When the light is at the desired brightness, release the button. 6. To turn the light ON and OFF, press and release the LIGHT DIMMER but- ton. The light will turn ON at the light level previously set (see step 5). Red light should turn on when any but- ton is pressed. If the light does not come on, replace the battery.
A storage bracket is supplied with the remote control for holding the transmitter when not in use. If you desire to use the bracket, use the two screws (supplied) and install it on a wall that is away from excess heat or humidity. When installing, orient the bracket so that the tab is at the top and away from the wall (Figure 17).
TAB
FAN/OFF
HI
FOR/REV
MED
LIGHT DIMMER
LOW
STORAGE BRACKET
®

Accessories
for your Ceiling Fan
Periodic cleaning of your new ceiling fan is the only maintenance that is needed.
When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish.
The use of any other control not specifically approved for this fan could result in fire, shock and per- sonal injury.
Abrasive cleaning agents are not required and should be avoided to prevent damage to finish.
Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock.
This product is designed to use only those parts supplied with this prod- uct and/or any accessories designat- ed specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
(if device contains a digital device)
This Class B digital apparatus meets all requirements of the Canadian Interference- Causing Equipment Regulations.

1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch start. blown. circuit fuses or circuit breakers. 2. Loose power line 2. Check line power connections connections to the fan, or to fan and wire. loose wire connections in the switch housing. 3. Wall switch is off. 3. Turn on wall switch. 4. Defective battery in remote 4. Check that the battery is good control transmitter. (red indicator light should illuminate when any button is pressed). 5. Code switches in remote 5. Check that both code switches control receiver and transmitter are set in the same positions. are not set in the same position.
WARNING: Make sure main power is turned off. 2. Fan sounds 1. Blades not attached to fan. 1. Attach blades to fan before noisy. operating. 2. Screws securing fan blade 2. Check to make sure the screws flanges to motor are loose. which attach the blade flanges to the motor are tight. 3. Wire connectors inside switch 3. Check to make sure wire housing rattling. connectors in switch housing are not rattling against each other or against the interior wall of the switch housing. WARNING: Make sure main power is turned off. 4. Screws holding blades to 4. Tighten screws securely. flanges are loose. 5. Loose screws in motor housing. 5. Check to make sure all screws in motor housing are snug (not over-tight) 3. Fan wobbles 1. Setscrew in motor coupling is 1. Raise coupling cover and tighten excessively. not tightened securely. setscrew securely. 2. Setscrew in the hanger ball/ 2. Tighten the setscrew in the downrod assembly is loose. hanger ball/downrod assembly. 3. Screws securing fan blade 3. Check to be sure screws which flanges to motor are loose. attach the fan blade flanges to the motor are tight. 4. Fan blade flanges not seated 4. Check to be sure that the properly. screws securing the fan blade flanges seat firmly. 5. Hanger bracket and/or ceiling 5. Tighten the hanger bracket outlet box is not securely screws to the outlet box, and/or fastened. secure outlet box. 6. Fan blades out of balance. 6. Interchanging an adjacent (side by-side) blade pair can redistribute the weight and result in smoother operation. Or use supplied balancing kit to balance blades.
! · ! · !



Key Model No. Model No. Model No. No. Description CF100AP00 CF100DBK00 CF100GES00
* Hanger Pack, Consisting of: 761655-34 761655-36 761655-35 1 Bracket, Hanger Assembly (1) — — — 2 Ball, Hanger (1) — — — 3 Downrod (1) — — —
* Parts Bag, Containing: 762655 762655 762655 4 Wire Connector (6) — — — 5 Stud, Threaded #8-32 x 1-1/4” (2) — — — 6 Knob, Knurled #8-32 (4) — — — 7 Lockwasher, External Tooth #8 (4) — — — 8 Clip, Hairpin (1) — — — 9 Pin, Clevis (1) — — — 10 Screw, Truss Head, #10-24 x 9mm (16) — — — 11 Washer, Fiber (16) — — — 12 Screw, Pan Head CR with Lockwasher,
1/4-20 x 11mm (11) — — — 13 Screw, Pan Head #8-32 x 7mm (4) — — —
14 Canopy, Ceiling (1) 762649-AP 762649-DBK 762649-GES
15 Cover, Coupling (1) 762671-AP 762671-DBK 762671-GES
16 Blade Set (full set for one fan) 762635 762635-17 762635-1
17 Flange Set (full set for one fan) 762642-AP 762642-DBK 762642-GES
18 Harness, Wiring (1) 762684 762684 762684
19 Housing, Switch (1) 762674-AP 762674-DBK 762674-GES
20 Fitter Assembly, Light (1) 763205-AP 763205-DBK 763205-GES
21 Glass, Lower (1) 762675 762675 762675-1
22 Bracket, Lower Ring (4) 762678-AP 762678-DBK 762678-GES
23 Screw, Mounting Bracket (8) 762681-AP 762681-DBK 762681-GES
24 Ring Assembly, Lower (1) 762679-AP 762679-DBK 762679-GES
25 Receiver, Remote Control (1) 762670 762670 762670
26 Transmitter, Remote Control (1) 762023 762023 762023
— Owner's Manual BP7355-1 BP7355-1 BP7355-1
Before discarding packaging material, be certain all parts have been removed.
HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION:
Part Numbers

What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is: As it applies to the motor, this warranty will last for the lifetime of your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Electric Co. Do To Correct Problems: Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price of your fan. WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE RESPONSIBLE FOR ALL COSTS OR REMOVAL, REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON ELECTRIC CO.
How State Law Relates To The Warranty: Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant ¥ St. Louis, MO 63136
Part No. F40BP73550001 Printed in China 09/07 Form No. BP7355-1
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| 1. Fan will not start. | 1. Fuse or circuit breaker blown. 2. Loose power line connections to the fan, or loose wire connections in the switch housing. 3. Wall switch is off. 4. Defective battery in remote control transmitter. 5. Code switches in remote control receiver and transmitter are not set in the same position. | 1. Check main and branch circuit fuses or circuit breakers. 2. Check line power connections to fan and wire. 3. Turn on wall switch. 4. Check that the battery is good (red indicator light should illuminate when any button is pressed). 5. Check that both code switches are set in the same positions. ! WARNING: Make sure main power is turned off. | p.13 |
| 2. Fan sounds noisy. | 1. Blades not attached to fan. 2. Screws securing fan blade flanges to motor are loose. 3. Wire connectors inside switch housing rattling. 4. Screws holding blades to flanges are loose. 5. Loose screws in motor housing. | 1. Attach blades to fan before operating. 2. Check to make sure the screws which attach the blade flanges to the motor are tight. 3. Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing. ! WARNING: Make sure main power is turned off. 4. Tighten screws securely. 5. Check to make sure all screws in motor housing are snug (not over-tight) | p.13 |
| 3. Fan wobbles excessively. | 1. Setscrew in motor coupling is not tightened securely. 2. Setscrew in the hanger ball/ downrod assembly is loose. 3. Screws securing fan blade flanges to motor are loose. 4. Fan blade flanges not seated properly. 5. Hanger bracket and/or ceiling outlet box is not securely fastened. 6. Fan blades out of balance. | 1. Raise coupling cover and tighten setscrew securely. 2. Tighten the setscrew in the hanger ball/downrod assembly. 3. Check to be sure screws which attach the fan blade flanges to the motor are tight. 4. Check to be sure that the screws securing the fan blade flanges seat firmly. 5. Tighten the hanger bracket screws to the outlet box, and/or secure outlet box. 6. Interchanging an adjacent (side by-side) blade pair can redistribute the weight and result in smoother operation. Or use supplied balancing kit to balance blades. | p.13 |