Instruction/ maintenance manual of the product FX 100 Elinca
Go to page of 16
English 190/260V elinca sa switzerland www .elinchr om.com Operating Manual Style FX 100/400 Elinca S.A Style FX 01.01.2007 ENG (73276) Printed in S wi tzerland.
1 PS: T echnical data subject to change. The listed values are guide v alues which may vary due to toler ances in components used. Introduction 2 Declaration of conformit y , disposal and recycling, C.
2 The quality of light and ex ceptional performance is the result of long research, application of demanding principles, the long experience of ELINCHROM in lighting products for the studio and the utilization of the latest technology in this area.
3 CE marking The shipped version of this device complies with the requirements of ECC dir ectives 89/336/ECC «Electromagnetic compatibility» and 73/23/ECC «Low voltage dir ective». Notational Conventions The meaning of the symbols and fonts used in this manual are as f ollows: Pa y particular attention to text marked with this symbol.
4 • T ransport the ash unit with care and only in its original packaging or another corresponding packaging t to protect it against knocks and jolts. • T ransport only in complete discharged conditions. W ait a minimum 30 minutes after removing from mains supply befor e packaging and transportation.
3 1 5 6 11 12 C A B locking ring handle The Style FX are adapted for oper ation on 190-260V/50-60Hz. Before connecting for the rst time, check to mak e sure that your modelling lamp coincides with the voltage line. They must always be connected to an earthed ( grounded) mains supply .
6 9 5 8 6 10 7 13 1 2 17 4 3 16 18 19 21 20 12 11 14 15 Overview of controls 1.Mains inlet socket 2.Mains fuse (slow blow) 3.Mains Illuminated on/off switch 4.Modelling fuse (f ast blow) 5.Open-ash 6.Synchro-sockets, Amphenol + jack 3.5 mm 7 .Digital power display and charge/discharge indicator 8.
2 3 1 Mains fuse Modelling fuse Mains switch (Only tempered) Mains socket 4 8 A T 4 AF Mains Supply With the MAINS SWITCH (3) switched off ("O" position), rmly push in the plug of the original ELINCHROM mains cord into the mains socket (1).
8 On/Off proportional 14 Increase 15 15 Decrease 23035 23101 23033 Modelling lamps and fuse (230V Version) Unit Modelling lamp Code Socket Fuse Code Style 100FX 100W krypton 23002 E27 2.5AF 19033 Style 400FX 100W krypton 23002 E27 2.5AF 19033 Option: 150W halostar 23035 E27 2.
9 10 Photocell receptor 5 T est and ready Cell (9) Modellling light controls Power displa y The actual ash power is shown in a f -stop compatible format. The power range is 5 f -stops. The digital display , provides continuous power indication of the ash and modelling lamp.
10 EL -Skyport triggers ashes without sync cor ds over a distance of approximately 100 m. Further detailed information please nd under : www .elinchrom.com / Products / RX Multi Remote Open ash "Test" Having pressed the touch pad to release a ash, the green «READ Y» light will appear again once the unit is recharged.
11 Training with Elinchrom lighting The Beginner’s Guide To Light / 72404 Only in English av ailable. Y our DVD Guide to better pictures, show how easy studio photograph y can be. Learn about ash units and why studio ash is just the better light source for portrait and universal photogr aphy .
12 Flash power J(Ws) 100 400 Power supply V 200/260 200/260 F-stop, 1m, 100 ISO , with reector 48° 32,5 64,5 Control range J(Ws) 6.25-100 25-400 Recycling time (230 V) s 0,2-0,5 0,3-1,2 Flash dura.
13 code Reectors Wide angle ø 16 cm /90° 26143 Compact ø 18 cm /60° 26144 Standard ø 21 cm /50° 26141 Mini soft ø 44 cm silver 26166 Mini soft ø 44 cm white 26168 Snoot & Grid 26061 Gri.
This ELINCHROM product will be repaired free of char ge by the vending agent if during a period of 24 months from date of purchase its working order is impaired thr ough a manufacturing or material defect. The fault y product should be immediately sent to the authorized dealer or ELINCA agent.
www.elinchrom.com.
An important point after buying a device Elinca FX 100 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Elinca FX 100 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Elinca FX 100 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Elinca FX 100 you will learn all the available features of the product, as well as information on its operation. The information that you get Elinca FX 100 will certainly help you make a decision on the purchase.
If you already are a holder of Elinca FX 100, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Elinca FX 100.
However, one of the most important roles played by the user manual is to help in solving problems with Elinca FX 100. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Elinca FX 100 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center