Instruction/ maintenance manual of the product TEC 40D Dometic
Go to page of 28
TEC 4 0 d Operation, maintenance and installation manual Libretto istruzioni per l’uso, la manutenzione e l’installazione Betriebs-, W artungs- und Installationsanleitung Manuel d’utilisation, d.
ENGLISH With Dometic at home everywhere. Thank you for your decision to buy an Dometic product. They all have been specially conceived for your vehicle, matching totally the requirements of leisure on.
©DOMETIC - 2007 All rights reserved - Printed in Italy - No part of this manual may be reproduced, copied or transmitted in any form or by any means without prior written permission from DOMETIC. Figures, descriptions, references and technical data contained in this manual are given as mere example and are not binding.
“The product is warranted in accordance with the enforced Law and regulations implementing the Direc- tive 1999/44/EC.” The Manufacturer ’ s warranty does not extend to Product failures, defects or damage arising from and/or attributable to a wrong installation.
Operation, Maintenance and Installation manual Generator Handleiding voor bediening, onderhoud en installatie Generator Manual de instrucciones para el uso, la manutención y la instalación Generador.
TEC 40D 4 user ’ s manual G B 1.2 Data plate 1.1 Purpose of the manual This manual has been made up by the Manufacturer and is an integrated part of the generator ’ s equipment. The information, if respected, will guarantee the correct use of the generator .
user ’ s manual 5 TEC 40D GB • T o prevent fire hazards and to keep the generator in an efficient working condition, do not close the same in a case or an enclosed space such as an alcove but install it in a well-ventilated area.
TEC 40D 6 user ’ s manual G B 1.5 Description of the generator W arning The TEC 40D generator has been designed and produced to be used only on caravans, motor homes and commercial vehicles. There fore it has not been designed to be used on other types of vehicles or on any kind of watercraft.
user ’ s manual 7 TEC 40D GB General informations 1 1.8 Operation description The main elements of the TEC 40D generator are: an engine (a), a permanent magnet alternator (b), an inverter (c), an internal control panel (d), a terminal board (e) and an external control panel (f).
TEC 40D 8 user ’ s manual G B 1.9 External control panel 1 General informations 1.10 Internal control panel Operation description MAIN SWITCH : turns the panel on/stops the generator ST ART BUTTON :.
user ’ s manual 9 TEC 40D GB DESCRIPTION UNIT OF MEASURE V ALUE VOL T AGE SUPPLIED V 230 ± 10% MAX CONTINUOUS POWER W 3500 ± 5% FREQUENCY Hz 50 ± 1% DIRECT CURRENT POWER V / A 12 / 10 THD % 1 CONSUMPTION g/HPh 190/200 WEIGHT kg 96.5 General informations 1 1.
TEC 40D 10 user ’ s manual G B 1 General informations 1.12 T able describing the alarm messages appearing on the display DISPLA YED MESSAGE DESCRIPTION GENERA TOR BEHA VIOUR ACTIONS LOW BA TTERY Indicates that the battery voltage is below the mini- mum value necessary to start the generator .
user ’ s manual 1 1 TEC 40D GB 1.14 Checking the oil level Remove the oil filler and clean the dipstick with a cloth. Refit by screwing the dipstick. Remove the dipstick and check that the oil level is between the two (min. and max.) marks. Add oil if necessary through the filler .
TEC 40D 12 user ’ s manual G B 2 Installation instructions 2.1 Instructions for fixing the generator 2 3 4 1.
user ’ s manual 13 TEC 40D GB 6 7 8 5.
TEC 40D 14 user ’ s manual G B Installation instructions 2 2.2 Instructions for installing the exhaust system We recommend positioning the elbow of the exhaust pipe in line with the length of the casing (as shown in the figure) so more vibrations can be absorbed.
user ’ s manual 15 TEC 40D GB Max 1.5m 3m Generator TEC 40D is equipped as standard with an electric pump for pumping fuel. The following should be done. The fuel tank should be installed with the tank basis at a maximum depth of 1.5 meters below the lower edge of the generator box.
TEC 40D 16 user ’ s manual G B Installation instructions 2 Cross-section mm 2 230V (power cables) Cross-section mm 2 12V (battery charger) Cross-section mm 2 Lenght up to 6m (battery connection) Cross-section mm 2 Lenght > 6m (battery connection) 4 2.
user ’ s manual 17 TEC 40D GB Battery connection N.B. T o start the generato r it is necessar y to use a 12VDC battery , with a minmum capacity of 60Ah. T o start the generator, connect it to the positive pole of the vehicle’s battery with a sheathed cable of a suitable cross-section as shown in the table.
TEC 40D 18 user ’ s manual G B SOLUTION The emergency stop switch is not to ON The starter is not powered up The electrical cables are broken The generator earth wire (or fuse) is broken No fuel Check the load supplied No fuel received from injectors The air filter is dirty The Air intakes are obstructed Inverter is damaged Load over 3.
user ’ s manual 19 TEC 40D GB 3.2 Check list and time intervals Maintenance chart Maintenance work required 8-15 Every 8-15 operating hours, or before each daily startup Check oil level Check combustion and cooling air intake zone.
TEC 40D 20 user ’ s manual G B T roubleshooting, maintenance, recycling 3 Important Old oil mou st not b e dispo sed of in t he env ironment , but lef t to a station specialised in the disposal and/or recycling of the same, respecting the laws in the country where the operations are carried out.
user ’ s manual 21 TEC 40D GB Air filter maintenance W arning Do not use diesel or solvents with a low evaporation point to clean the air filter element as it could catch fire or explode. Important I f the air filter is dirty this reduces the flow of air to the engine.
TEC 40D 22 G B MOTORE HA TZ DIESEL 20 19 17 13 12 8 7 29 28 27 26 14 9 11 + 2 3 9 8 6 5 4 11 10 12 1 7 N OW K N 5 8 7 6 2 1 4 3 23 12 T 11 10 9 E GR E BL U YE L BLA BR O RE D VI OL PI N GR E WH I E T .
23 TEC 40D GB CONNECTION TO THE EXTERNAL POWER SUPPL Y 1 230 230 12 1 R1 R3 3 2 R2 R4 4 A2 A1 AG1 13 GENERA TOR AG1 13 SWITCHING ACCESSOR Y (available on demand) 1) Use cables of suitable section (see ta- ble in paragraph “electrical connection”).
.
.
Via V irgilio, 3 - 47100 Forlì - T el. 0543/754213 Fax.0543/756631 DOMETIC ST095 r0.
An important point after buying a device Dometic TEC 40D (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Dometic TEC 40D yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Dometic TEC 40D - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Dometic TEC 40D you will learn all the available features of the product, as well as information on its operation. The information that you get Dometic TEC 40D will certainly help you make a decision on the purchase.
If you already are a holder of Dometic TEC 40D, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Dometic TEC 40D.
However, one of the most important roles played by the user manual is to help in solving problems with Dometic TEC 40D. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Dometic TEC 40D along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center