INSTRUCTIONS
CFSM1254 WATER SOFTENER
Installer: Please leave this manual with owner/operator. Owner/Operator: Please retain for operation and future maintenance instructions.

SAFETY INFORMATION Read, understand, and follow all safety information contained in these instructions prior to installation and use of the CFSM1254 Water Softener. Retain these instructions for future reference. Failure to follow installation, operation and maintenance instructions may result in property damage and will void warranty.
Intended use: The CFSM1254 Water Softener is intended for use in softening water and has not been evaluated for other uses. The system must be installed indoors near the point of entry of a water line, and be installed by qualifi ed professional installers according to these installation instructions.
To reduce the risk associated with choking: • Do not allow children under 3 years of age to have access to small parts during the installation of this product.
To reduce the risk associated with ingestion of contaminants: • Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
To reduce the risk of physical injury: • Shut off inlet water supply and depressurize system as shown in manual prior to service.
To reduce the risk associated with back strain due to the heavy weight of the various system components: • Follow safe lifting procedures. CAUTION
To reduce the risk associated with property damage due to water leakage:
To reduce the risk associated with property damage due to plugged water lines: • Pay particular attention to correct orientation of control valve. Water fl ow should match arrow on control valve. The Inlet and Outlet of other water treatment equipment products will vary depending on the control valve brand used.

1 BEFORE INSTALLATION 2 INSTALLATION 3 CONTROL VALVE PROGRAMMING AND REGENERATION 4 MAINTENANCE 5 TROUBLESHOOTING AND SERVICE INSTRUCTIONS 6 SPECIFICATIONS & OPERATING DATA 7 PARTS LIMITED WARRANTY
When properly installed, operated, and maintained, your new softener will provide many years of dependable service. Before starting the installation please read this manual all the way through for an overview, and then follow the installation in proper sequence. Failure to follow instructions will void warranty.
Inspect the equipment for shipping damage. If damaged, notify the transportation company and request a damage inspection.
Handle the equipment with care. Damage can result if dropped or if the brine tank is set on sharp, uneven projections on the fl oor. When handling, do not turn the water softener unit upside down.
An analysis of your water should be made prior to the selection of your water conditioning equipment. Your dealer will generally perform this service for you, and may send a sample to the factory for analysis and recommendations. Enter your analysis below for your permanent record.
Hardness gpg Tannins (Humic Acid) ppm
Iron (Fe) ppm Hydrogen Sulfi de (H2S) ppm
Manganese (Mn) ppm Other ppm
pH ppm Other ppm
IMPORTANT NOTES Hydrogen sulfi de (H2S) must be tested for at the well site. For accuracy, the sample must be drawn with the pump RUNNING, and the test be completed within ONE minute after the sample is drawn. Softeners are designed to reduce hardness but can handle reasonable amounts of soluble iron if consideration is given to content when selecting model and regeneration settings. To treat sulfur (hydrogen sulfi de), bacte- rial iron, precipitated iron or very high levels of soluble iron requires special equipment in addition to a water softener. For best results, a Chem-Free Iron Reduction System is recommended for use on waters containing more than 2 ppm of iron.

Two water system conditions must be checked carefully to avoid unsatisfactory operation or equipment damage: 1) MINIMUM water pressure required at the water softener inlet is 20 psi (1.4 bar). IF WATER PRESSURE IS OVER 80 psi (552 kPa), A PRESSURE REDUC- ING VALVE MUST BE INSTALLED IN THE WATER SUPPLY LINE AHEAD OF THE WATER SOFTENER.
To reduce the risk associated with property damage due to water leakage:
NOTE: If you have a municipal or a community water supply and daytime water pressure is 85 psi or more, nighttime pressure may exceed 100 psi. Call your local water department or plant operator to obtain pressure readings. If you have a private well, the gauge on the pressure tank will indicate the high and low system pressure. Record your water pressure data below:
Water Pressure:
Low psi High psi
To reduce the risk associated with property damage due to water leakage: • Do not install system where water lines could be subjected to vacuum conditions without appropriate measures for vacuum prevention.
The installer should take appropriate measures if there is the possibility a vacuum may occur. This would include the installation of an appropriate
device in the supply line to the system, i.e., a vacuum breaker or backfl ow prevention device. Vacuum damage voids the factory warranty.
Select the location of your water softener with care. Various conditions which contribute to proper location are as follows:
To reduce the risk associated with ingestion of contaminants: • Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
To reduce the risk associated with property damage due to water leakage:

To reduce the risk associated with property damage due to plugged water lines: • Pay particular attention to correct orientation of control valve. Water fl ow should match arrow on control valve. The Inlet and Outlet of other water treatment equipment products will vary depending on the control valve brand used.
To reduce the risk associated with a hazardous voltage: • If the electrical system requires use of the cold water system as an electrical safety ground, a jumper must be used to ensure a suffi cient ground connection across the fi lter installation piping — refer installation to qualifi ed personnel.
Sodium Information: Water softeners utilizing sodium chloride for regeneration add sodium to the water softened water. Persons who are on sodium re- stricted diets should consider the added sodium as part of their overall sodium intake. As a reference as to how much sodium is added to softened water consider the following. For each grain per gallon of water hardness that is exchanged from the water supply, 7.5 milligrams per liter of sodium will be added to the softened water. e.g. 10 grains per gallon (gpg) exchanged will add 75 milligrams of sodium to the softened water.


WELL WATER
SWITCH. PRESSURE
STANDARD WELL INSTALLATION

WATER RAW
CHECK VALVE
PUBLIC WATER SUPPLY INSTALLATION
Figure 1. Typical Installation
CAUTION
To reduce the risk associated with property damage due to water leakage:
To reduce the risk associated with property damage due to plugged water lines: • Pay particular attention to correct orientation of control valve. Water fl ow should match arrow on control valve. The Inlet and Outlet of other water treatment equipment products will vary depending on the control valve brand used.

facility. Locate the parts package and install the bypass and adapter fi ttings on the control valve to facilitate the connection to the customer’s water supply.

from complete system by opening nearest faucet to drain system.
adapters. MAKE CERTAIN WATER FLOW ENTERS THROUGH INLET AND DISCHARGES THROUGH OUTLET.

To reduce the risk associated with a hazardous voltage: • If the home electrical system requires use of the cold water system as an electrical safety ground, a jumper must be used to ensure a suffi cient ground connection across the fi lter installation piping — refer installation to qualifi ed personnel.


CONTROL VALVE BODY
BRINE TANK
Figure 2. SOFTENER AND BRINE TANK ASSEMBLY, TOP VIEW


rate below minimum required for backwash, DRAIN LINE MUST be sized according to run length and relative height. Be careful not to bend fl exible drain tubing sharply enough to cause “kinking” (if kinking occurs DRAIN LINE MUST BE REPLACED). Typical examples of proper DRAIN LINE diameters are:
Some areas prohibit the use of fl exible drain lines. Check with local code offi cials prior to
installation.
water, provide an air-gap of at least 2” or 2 pipe diameters between end of drain hose and drain (Figure 3). DO NOT raise DRAIN LINE more than 10 ft. above fl oor.
fi tting located on the left side of the CONTROL VALVE. Connect the other end to the SAFETY BRINE VALVE ELBOW inside of the brine well in the brine tank. To do so remove the retaining clip from the brine line fi tting on the control valve. The retaining clip is holding a plastic insert sleeve and needs to be inserted into the polyeth- ylene tubing before installing the tubing into the fi tting elbow and hand tighten only. CAUTION: Do not use pliers or wrenches to tighten as damage may occur and will void the manufacturer’s warranty.
Discharge of line must be lower than OVERFLOW FITTING. DO NOT INTERCONNECT OVERFLOW LINE WITH VALVE DRAIN LINE.
“BYPASS” position. After all plumbing connections have been completed, open main water shut-off valve or restore power to well pump. Check for leaks and correct as necessary.
Step 12)Plug CONTROL VALVE POWER CORD into 120v/60Hz, non-switched power
source. Manually stage control to BACKWASH POSITION and then unplug power cord to prevent the unit from advancing automati- cally.
allow the unit to fi ll slowly from the bottom up, reducing air en- trapment. Allow unit to fi ll slowly, failure to do so could result in loss of resin to the drain. Once a steady stream of water, no air, is fl owing to drain the inlet and outlet knobs on the bypass can be fully opened.
next regeneration position. Repeat the process until the valve is in Service Position (Time will be on the display).
settings. NOTE: Regeneration settings for the control valve are factory preset. The control valve design permits adjustment
of the salt setting. This adjustment may be necessary when unusual operating conditions exist, such as high concentrations of iron, manganese or hardness and/or high fl ow rates or daily water consumption.
Under normal circumstances removal of valve should not be required. However, if it must be removed, it can be done by disassembling the quick release clamp, and latch. Pressure should be relieved before attempting any disassembly. Upon reassembly, all o-rings should be lubricated with silicone grease. Reassemble clamp as shown in Figure 5. MAKE SURE ARROWS ON LATCH SIDE OF CLAMP ARE ALIGNED.




(Step 1) Press NEXT and simultaneously for 3 seconds.
(Step 2) Hardness: Set the amount of hardness in grains of hardness as calcium carbonate per gallon using the or buttons. The default is 20 with value ranging from 1 to 150 in 1 grain increments. Note: The grains per gallon can be increased if soluble iron needs to be reduced. Press NEXT to go to Step 3. Press REGEN to exit Installer Display Settings.
(Step 3) Day Override: Day Override sets the number of days between regenerations and sets the maximum number of days between regenerations. If value is set as a number (allowable range from 1 to 28) a regeneration initiation will be called for on that day even if suffi cient number of gallons were not used to call for a regeneration. Set Day Override using or buttons. • number of days between regeneration (1 to 28); or “OFF”.
Press NEXT to go to Step 4. Press REGEN to return to previous step.
(Step 4) Next Regeneration Time (hour): Set the hour of day for regeneration using or buttons. AM/PM toggles after 12. The default time is 2:00 a.m. Press NEXT to go to Step 5. Press REGEN to return to previous step.
(Step 5) Next Regeneration Time (minutes): Set the minutes of day for regeneration using or buttons. Press NEXT to exit Installer Display Settings. Press REGEN to return to previous step.
To initiate a manual regeneration immediately, press and hold the “REGEN” button for three seconds. The system will begin to regeneration immediately. The control valve may be stepped through the various regeneration cycles by pressing the “REGEN” button.
Power Lost If power goes out for less than two hours, the system will automatically reset itself. If an extended power outage occurs, the time of day will fl ash on and off which indicated the time of day should be reset. The system will remember the rest.
Error Message If the word “error” and a number are alternately fl ashing on the display contact the “Technical Support Services Department” at CUNO Incorporated, phone number 1-866-693-2543 for help. This indicates that the valve was not able to function properly.



(Step 1) Press or simultaneously for 3 seconds. If screen in step does not appear in 5 seconds the lock on the valve is activated. To unlock press, , NEXT, , and SET CLOCK in sequence, then press NEXT and simultaneously for 3 seconds.
(Step 2) Days, since last regeneration: This display shows the days since the last regeneration occurred. Press the NEXT button. Press REGEN to exit Diagnostics.
(Step 3) Gallons, since last regeneration: This display shows the number of gallons that have been treated since the last regeneration. This display will equal zero if a water meter is not installed. Press the NEXT button. Press REGEN to return to previous step.
(Step 4) Gallons, reserve capacity used for last 7 days: This display shows 0 day (for today) and fl ashes the reserve capacity. Pressing the button show day 1 (which would be yesterday) and fl ashes the reserve capacity used. Pressing the button again will show day
2 (the day before yesterday) and reserve capacity. Keep press- ing the button to show the gallons for days 3, 4, 5 and 6. The button can be pressed to move backwards in the day series. Press the NEXT button at any time. Press REGEN to return to previous step.
(Step 5) Gallons, 63 day usage history: This display shows day 1 (for yesterday) and fl ashes
the number of gallons treated yesterday. Pressing the button will show day 2 (which would be the day before yes- terday) and fl ashes the number of gallons treated on that day. Continue to press the button to show the
maximum number of gallons treated for the last 63 days. This display will show dashes if a water meter is not installed. Press the NEXT button at any time. Press REGEN to return to previous step.
(Step 6) Flow rate, current: Turn the water on at one or more taps in the building. The fl ow rate in gallons per minute will be displayed. If fl ow stops the value will fall to zero in a few seconds. This display will equal zero if a water meter is not installed. Press the NEXT button. Press REGEN to return to previous step.
(Step 7) Flow rate, maximum last seven days: The maximum fl ow rate in gallons per minute that occurred in the last seven days will be displayed. This display will equal zero if a water meter is not installed. Press the NEXT button. Press REGEN to return to previous step.
(Step 8) Gallons, total used since last reset: The total number of gallons used since last reset will be displayed. This display will equal zero if a water meter is not installed. Press the NEXT button. Press REGEN to return to previous step.
(Step 9) Days, total number since last reset: The total number of days the control valve has been in ser- vice since last reset will be displayed. Press the NEXT button. Press REGEN to return to previous step.
(Step 10) Regenerations, total number since last reset: The total number of regenerations that have occurred since last reset will be displayed. Press the NEXT button to exit Diagnostics. Press REGEN to return to previous step. To lock settings press , NEXT, , and SET CLOCK in sequence.


(Step 1) Press or simultaneously for 3 seconds and release. Then press and simultaneously and release. If screen, to the left, does not appear is 5 seconds the lock on the valve is activated. To unlock press , NEXT, and SET CLOCK in sequence, then press and . Then press and simultaneously and release.
(Step 2) Software Version: This display shows the software version of the valve. Press the NEXT but- ton to go to the next step or press REGEN to exit Valve History.
(Step 3) Flow rate, maximum since startup: This display shows the maximum fl ow rate in gallons per minute that has occurred since startup. This display will equal zero if a water meter is not function- ing. Press the NEXT button to go to the next step. Press REGEN to return to previous step.
(Step 4) Gallons, total used since start-up: This display shows the total gallons. This display shows the total days since start-up. Press the NEXT button to go to the next step. Press REGEN to return to previous step.
(Step 5) Days, total since start-up: This display shows the total days since start-up. Press the NEXT button to go to the next step. Press REGEN to return to previous step.
(Step 6) Regenerations, total number since start-up: This display shows the total number of regen- erations that have occurred since start-up. Press the NEXT button to go to the next step. Press REGEN to return previous step.
(Step 7) Error, number of occurrences since start-up: This display shows E and the total number of errors that have occurred since start-up. Press the NEXT button to exit Valve History. Press REGEN to return to previous step. To lock settings press , NEXT, and SET CLOCK in sequence.


General Operation When the system is operating, one of two displays will be shown. Pressing NEXT will alternate between the displays. One of the displays is always the current time of day. The sec- ond display is one of the following: days remaining or gallons remaining. Days remaining is the number of days left before the system goes through a regeneration cycle. Capacity re- maining is the number of gallons that will be treated before the system goes through a regeneration cycle. The user can scroll between the displays as desired.
REGEN TODAY will be displayed if a regeneration is expected “Tonight.”
If the system has called for a regeneration that will occur at the preset time of regeneration, the words “REGEN TODAY” will appear on the display.
When water is being treated (i.e. water is fl owing through the system) the word “SOFTENING” fl ashes on the display if a water meter is in- stalled.
Regeneration Mode Typically a system is set to regenerate at a time of low water usage. An example of a time with low water usage is when members of a household are asleep. If there is a demand for water when the system is regenerating, untreated water will be used.
When the system begins to regenerate, the display will change to include information about the step of the regeneration process and the time remaining for that step to be completed. The system runs through the steps automatically and will reset itself to help provide treated water when the regeneration has been completed.
Manual Regeneration Sometimes there is a need to regenerate the system sooner than when the system calls for it, usually referred to as manual regen- eration. There may be a period of heavy water usage because of guests or a heavy laundry day.

REGEN TODAY will Flash if a regeneration is expected “Tonight.”
To initiate a manual regeneration at the present delayed regeneration time, press and release “REGEN”. The words “REGEN TODAY” will fl ash on the display to indicate that the system will regenerate at the preset delayed regeneration time.
To initiate a manual regeneration immediately, press and hold the “REGEN” button for 3 seconds. The system will begin to regenerate immedi- ately. The request cannot be cancelled.
Set Time of Day The user can also set the time of day. Time should only need to be set after extended power outages or when daylight saving time begins or ends. If an extended power out- ages or when daylight saving time begins or ends. If an extended power outage occurs, the time of day will fl ash on and off which indicates the time of day should be reset.


Replenishment of Salt Supply: The salt storage capacity of the brine tank is approximately 135 lbs. (61 kg). During each regeneration a specifi c amount of salt is consumed, thus requiring its periodic replenishment (the frequency and salt dosage level is dependent on the regeneration schedule). Always replenish salt before the supply is exhausted for a continuous supply of softened water.
Type of Salt to Use: Any type of water softener salt may be used. There are advantages and disadvantages to every type of salt. Please ask your local dealer for his advice. Your unit is designed to compensate for the disadvantages. However the use of block salt is not encouraged due to its possible problems in making enough brine for regeneration purposes.
Brine Tank Clean-Out: To prevent service problems the brine tank should be emptied and fl ushed out with a garden hose when dirt and other insolubles accumulate.
Steps to follow: (1) Disconnect brine line at either end.
(2) Turn brine tank upside down and discard old salt.
(3) Rinse out with a garden hose.
(4) Reconnect brine line.
(5) Before loading salt, using a pail or garden hose, add enough water to the brine tank to cover the salt grid lower shelf on 15” x 15” x 34” brine tank at least one (1) inch in depth. Then add initial salt to brine tank and add one (1) cup of unscented laundry bleach to the brine well.
(6) Perform approximately once a year if rock salt is used; with other types of salt, approximately once every other year.
Preventing Iron-Fouling of Mineral Bed: If iron is present in the water supply, the softener mineral bed will eventually become iron-fouled, resulting in reduced softening capacity and rust-stained fi xtures. Mixing one to two ounces of IRON-X Mineral Cleaner with every 80 lbs. of salt added to brine tank will help minimize these problems from occurring. IRON-X is available from your dealer.
Periodically Check Time of Day Setting: Power outages will cause “TIME OF DAY” setting to become incorrect. To correct, refer to Section 4.
Malfunction of Unit: Your water softener, under normal conditions, should provide years of virtually trouble-free service; however, since it is a mechanical device, it can malfunction. (Refer to Section 5, SERVICE INSTRUCTIONS, if necessary).
Change of Operating Conditions: Should your family size, your water usage habits, or your water quality change, the regeneration program settings may have to be adjusted. Consult your dealer if any of the above occur.
Special Service Instructions: Under normal circumstances removal of valve should not be required. However, if it must be removed, it can be done by disassembling the quick release clamp, and latch. Pressure should be relieved before attempting any disassembly. Upon reassembly, all o-rings should be lubricated with silicone grease. Reassemble clamp as shown in Figure 5. MAKE SURE ARROWS ON LATCH SIDE OF CLAMP ARE ALIGNED.

Figure 6. CLAMP ASSEMBLY

A. AC Adapter unplugged A. Connect power
B. No electric power at outlet B. Repair outlet or use working outlet
C. Problem with AC Adapter C. Replace AC Adapter
D. Problem with PC Board D. Replace PC Board
A. Switched outlet A. Use uninterrupted outlet
B. Power outage B. Reset time of day
C. Problem with PC board C. Replace PC board
A. Bypass valve in bypass position A. Put bypass valve in service position
B. Meter connection disconnected B. Connect meter to PC board
C. Restricted/stalled meter turbine C. Remove meter and check for rotation or foreign material
D. Problem with meter D. Replace meter
E. Problem with PC board E. Replace PC board
A. Power outages A. Reset control valve to correct time of day
B. Time of day not set correctly B. Reset to correct time of day
C. Time of regeneration incorrect C. Reset regeneration time
A. Control valve has just been serviced or unplug power source jack (black wire) and plug back in to reset control valve.
A. Press NEXT and REGEN for 3 seconds
B. Foreign matter is lodged in control valve B. Check piston and spacer stack assembly
C. High drive forces on piston C. Replace piston(s) and spacer stack assembly
Error Code 1001 - Unable to recognize start of regeneration Error Code 1002 - Unexpected stall Error Code 1003 - Motor ran too long, timed out trying to reach next cycle position Error Code 1004 - Motor ran too long, timed out trying to reach home position
D. Control valve piston not in home position seconds D. Press NEXT and REGEN for 3 seconds or unplug power source jack (black wire) and plug back in to reset control valve
E. Motor not inserted fully to engage pinion, motor wires broken or disconnected, motor failure
E. Check motor and wiring. Replace motor if necessary
F. Drive gear label dirty or damaged, missing or broken gear
F. Replace or clean drive gear
If other Error Codes display, contact the factory
G. Drive bracket incorrectly aligned to back plate G. Reseat drive bracket properly
H. PC board is damaged or problematic H. Replace PC board
I. PC board incorrectly aligned to drive bracket I. Ensure PC board is correctly snapped on to drive bracket
A. Motor not operating A. Replace motor
B. No electric power at outlet B. Repair outlet or use working outlet
C. Problem with AC Adapter C. Replace AC Adapter
D. Problem with PC board D. Replace PC board
E. Broken drive gear or drive cap assembly E. Replace drive gear or drive cap assembly
F. Broken piston retainer F. Replace drive cap assembly
G. Broken main or regenerant piston G. Replace main or regenerant piston
A. AC Adapter unplugged A. Connect AC Adapter
B. No electric power at outlet B. Repair outlet or use working outlet
C. Broken drive gear or drive cap assembly C. Replace drive gear or drive cap assembly
D. Problem with PC board D. Replace PC board
A. Bypass valve in bypass position A. Put bypass valve in normal operating position
B. Meter connection disconnected B. Connect meter to PC board
C. Restricted/stalled meter turbine C. Remove meter and check for rotation or foreign matter
D. Problem with meter D. Replace meter
E. Problem with PC board E. Replace PC board
F. Set-up error F. Check control valve set-up procedure
A. Power has been out more than two hours, the AC Adapter was unplugged and then plugged back into the wall outlet, the AC Adapter plug was unplugged and then plugged back into the board or the NEXT and REGEN but- tons were pressed to reset the valve
A. Reset the time of day

Drive Assembly: Remove the valve cover to access the drive assembly.
IMPORTANT NOTE: Disconnect the power source plug (black wire) from the PC board prior to disconnecting the motor or water meter plugs from the PC board. The power source plug connects to the four-pin jack. The motor plug connects to the two-pin jack on the left-hand side of the PC board. The water meter plug (grey wire) connects to the three-pin jack on the far right-hand side of the PC board.
The PC board can be removed separately from the drive bracket but it is not recommended. Do not attempt to remove the display panel from the PC board. Handle the board by the edges. To remove the PC board from the drive bracket, unplug the power, water meter and motor plugs from the PC board. Lift the middle latch along the top of the drive bracket while pulling outward on the top of the PC board. The drive bracket has two plastic pins that fi t into the holes on the lower edges of the PC board. Once the PC board is tilted about 45° from the drive bracket it can be lifted off of these pins. To reinstall the PC board, position the lower edge of the PC board so that the holes in the PC board line up with the plastic pins. Push the top of the PC board towards the valve until it snaps under the middle latch, weave the power and water meter wires into the holders and reconnect the motor, water meter and power plugs.
The drive bracket must be removed to access the drive cap assembly and pistons or the drive cap gear cover. It is not necessary to remove the PC board from the drive bracket to remove the drive bracket. To remove the drive bracket, start by removing the plugs for the power source and the water meter. Unweave the wires from the side holders. Two tabs on the top of the drive back plate hold the drive bracket in place. Simultaneously lift the two tabs and gently ease the top of the drive bracket forward. The lower edge of the drive bracket has two notches that rest on the back plate. Lift up and outward on the drive bracket to disengage the notches.
To reassemble, seat the bottom of the drive bracket so the notches are engaged at the bottom of the drive back plate. Push the top of the drive bracket toward the two latches. The drive bracket may have to be lifted slightly to let the threaded piston rod pass through the hole in the drive bracket. Maintain a slight engaging force on top of the drive bracket while defl ecting the bracket slightly to the left by pressing on the side of the upper right corner. This helps the drive gears mesh with the drive cap assembly. The drive bracket is properly seated when it snaps under the latches on the drive back plate. If resistance is felt before latching, then notches are not fully engaged, the piston rod is not in the hole, the wires are jammed between the drive bracket and drive back plate, or the gear is not engaging the drive cap assembly. To inspect the drive gears, the drive gear cover needs to be removed. Before trying to remove the gear cover, the drive bracket must be removed from the drive back plate. (Refer to the proceeding instructions regarding removing the drive bracket from the drive back plate. The drive gear cover can be removed from the drive bracket without removing the motor or the PC board.) The drive gear cover is held in place on the drive bracket by three clips. The largest of the three clips is always orientated to the bottom of the drive bracket. With the PC board facing up, push in and down on the large clip on the drive gear cover. Handle the cover and the gears carefully so that the gears do not fall off of the pegs in the cover.
Replace broken or damaged drive gears. Do not lubricate any of the gears. Avoid getting any foreign matter on the refl ective coating because dirt or oils may interfere with pulse counting.
The drive gear cover only fi ts on one way, with the large clip orientated towards the bottom. If all three clips are outside of the gear shroud on the drive bracket and the drive gear cover slips easily into place.
The drive bracket does not need to be removed from the drive plate if the motor needs to be removed. To remove the motor, disconnect the power and motor plugs from the jacks on the PC board. Move the spring clip loop to the right and hold. Rotate the motor at least a 1/4 turn in either direction so the wires are vertical (up & down) before gently pulling on the wire connectors to remove the motor. Pulling directly on the wires without rotating the motor may break the wires off the motor.
Replace the motor if necessary. Do not lubricate the motor or the gears. To reinstall the motor, move the spring clip loop to the right and hold. Gently turn the motor while inserting so that the gear on the motor meshes with the gears under the drive gear cover. Release the spring clip loop and continue to rotate the motor until the wires are horizontal and the motor housing engages the small plastic bulge inside the drive bracket motor retainer. Reconnect the motor plug to the two-pronged jack on the lower left hand side of the PC board. If the motor will not easily engage with the drive gears when reinstalling, lift and slightly rotate the motor before reinserting. Reconnect the power.
Replace the valve cover. After completing any valve maintenance, press and hold NEXT and REGEN buttons for 3 seconds or unplug power source jack (black wire) and plug back in. This resets the electronics and establishes the service piston position. The display should fl ash all wording, then fl ash the software version (e.g. 181) and then reset the valve to the service position.
Drive Cap Assembly, Main Piston and Regenerant Piston: The drive assembly must be removed to access the drive cap assembly. The drive cap assembly must be removed access the piston(s). The drive cap assembly is threaded into the control valve body and seals with an o-ring. To remove the drive cap assembly use the special plastic wrench or insert a ¼” to ½” fl at blade screwdriver into one of the slots around the top 2” of the drive cap assembly so it engages the notches molded into the drive back plate around 2” or the piston cavity. See Figure 7. The notches are visible through the holes. Lever the screwdriver so the drive cap assembly turns to the left. Once loosened, unscrew the drive cap assembly by hand and pull straight out. The drive cap assembly contains the drive cap, the main drive gear, drive cap spline, piston rod and various other parts that should not be dissembled in the fi eld. The only replaceable part on the drive cap assembly is the o-ring. Attached to the drive cap assembly is the main piston and a regenerant piston.
The regenerant piston (the small diameter one behind the main piston) is removed form the main piston by pressing sideways and unsnapping if from its latch. Chemically clean in dilute sodium or vinegar, or replace the regenerant piston if needed. To remove the main piston fully extend the piston rod and then unsnap the main piston from its latch by pressing on the side with the number. Chemically clean in dilute sodium bisulfi te or vinegar, or replace the main piston.


Reattach the main piston to the drive cap assembly. Reattach the regenerant piston (if needed) to the main piston. Do not lubricate the piston rod, main piston or regenerant piston. Lubricant will adversely affect the clear lip seals. Reinsert the drive cap assembly and piston into the spacer stack assembly and hand tighten the drive cap assembly. Continue to tighten the drive cap assembly using a screwdriver as a ratchet until the black o-ring on the spacer stack as- sembly is no longer visible through the drain port. Excessive force can break the notches molded into the dive back plate. Make certain that the main drive gear still turns freely.
The exact position is not important as long as the main drive gear turns freely. Reattach the drive assembly to the control valve and connect all plugs. After completing any valve maintenance, press and hold NEXT and REGEN buttons for 3 seconds or unplug power source jack (black wire) and plug back in. This resets the electronics and establishes the service piston position. The display should fl ash all wording, then fl ash the software version (e.g. 181) and then reset the valve to the service position.
Spacer Stack Assembly: To access the spacer stack assembly remove the drive assembly, drive cap assembly and piston. The spacer stack assembly can be removed easily without tools by using thumb and forefi nger. Inspect the black o-rings and clear lip seals for wear or damage. Replace the entire stack if necessary. Do not disassemble.
The spacer stack assembly may be chemically cleaned (dilute sodium bisulfi te or vinegar) or wiped with a soft cloth.
The spacer stack assembly can be pushed in to the control valve body bore by hand. Since the spacer stack assembly can be compressed it is easier to use a blunt object (5/8” to 1-1/8” in diameter) to push the center of the assembly into the control valve body. The assembly is properly seated with at least four threads are exposed (approximately 5/8’). Do not force the spacer stack assembly in. The control valve body bore interior can be lubricated with silicone to allow for easy insertion of the entire stack. Do not use silicone or any other type of lubricant on the clear lip seals or the piston.
Reattach the drive cap assembly and piston(s) and the drive assembly.
After completing any valve maintenance, press and hold NEXT and REGEN buttons for 3 seconds or unplug power source jack (black wire) and plug back in. This resets the electronics and establishes the service piston position. The display should fl ash all wording, then fl ash the software version (e.g. 181) and then reset the valve to the service position.
Injector Cap, Screen, Injector Plug and Injector: Unscrew the injector cap and lift off. Loosen cap with special plastic wrench or pliers if necessary. Attached to the injector cap is a screen. Remove the screen and clean if fouled. The plug and/or injector can be pried out with a small screwdriver. The plug can be wiped clean. If the plug leaks replace the entire plug. The injec- tor consists of a throat and a nozzle. Chemically clean the injector with vinegar or sodium bisulfi te. The holes can be blown out with air. Both pieces have a small diameter holes that control the fl ow rates of water to insure that the proper concentration of regenerant is used. Sharp objects, which can score the plastic, should not be used to clean the injector. Scoring the injector or increasing the diameter of the hole could change the operating parameters of the injector. Push the plug(s) and/or injectors fi rmly in place, replace the screen and hand tighten the injector cap.
Refi ll Flow Control Assembly or Refi ll Port Plug: To clean or replace the refi ll fl ow control, pull out the elbow-locking clip and then pull straight up on the elbow. Replace the elbow locking clip in the slot so that it is not misplaced. Twist to remove the white fl ow control retainer. The fl ow control can be removed by prying upward through the side slots of the retainer with a small fl at blade screwdriver.
Clean the fl ow control or the white fl ow control retainer using dilute sodium bisulfi te or vinegar. Do not use a wire brush. If necessary, replace the fl ow control, o-ring on the fl ow control retainer, or the o-ring on the elbow.
Reseat the fl ow control so the rounded end is visible in the fl ow control. Reseat the white fl ow control retainer by pushing the retainer into the elbow until the o-ring seats. Remove locking clip, push down on elbow to reseat and insert locking clip. Do not use petroleum jellies, oils, or other unacceptable on o-rings. A silicone lubricant may be used on the o-ring on the elbow or the white retainer.
Water Meter or Meter Plug: The water meter assembly is connected to the PC board by a wire. If the entire water meter assembly is to be replaced, remove the control valve cover and discon- nect the power source and water meter plugs from the PC Board. Unlatch the drive assembly and lean if forward. Unthread the water meter wire from the side of the drive assembly and through the drive back plate. To reinstall, rethread the water meter wire through the drive back plate and the side of the drive assembly. Reattach the drive assembly and the water meter and power plugs. If no water meter wire is visible, then a plug is installed, not a water meter. The water meter wire does not need to be removed from the PC board if the water meter is only being inspected and cleaned. To remove the water meter assembly, unscrew the meter cap on

the left side of the control valve. Pliers may be used to unscrew the nut if necessary. With the nut removed, a slot at the top of the water meter is visible. Twist a fl at blade screwdriver in the slot between the control valve body and the meter. When the meter is part way out it is easy to remove the water meter from the housing. Once the water meter is removed from the control valve body, gently pull forward on the turbine to remove it from the shaft.
Do not use a wire brush to clean the turbine. Wipe with a clean cloth or clean in dilute sodium bisulfi te or vinegar. The turbine can be immersed in the chemical. Do not immerse electronics. If the turbine is scored or damaged or the bearing on the turbine are worn, replace the turbine.
Do not lubricate the turbine shaft. The turbine shaft bearings are prelubricated. Do not use petroleum jellies, oils, or other unacceptable lubricants on the o-ring. A silicone lubricant may be used on the black o-ring.
Snap the turbine on the shaft and reinsert the water meter into the side slot. Hand tighten the nut. Do not use a pipe wrench to tighten nut.
Bypass Valve: The working parts of the bypass valve are the rotor assemblies that are contained under the bypass valve caps. Before working on the rotors, make sure the system is depressurized. Turn the red arrow shaped handles towards the center of the bypass valve and back several times to ensure rotor is turning freely.
The nuts and caps are designed to be unscrewed or tightened by hand. If necessary a pliers can be used to unscrew the nut or cap. Do not use a pipe wrench to tighten or loosen nuts or caps. Do not place screwdriver in slots on caps and/or tap with a hammer. To access the rotor, unscrew the cap and lift the cap, rotor and handle out as one unit. Twisting the unit as you pull it out will help to remove it more easily. There are three o-rings: one under the rotor cap, one on the rotor stem and the rotor seal. Replace worn o-rings. Clean rotor. Reinstall rotor.
When reinstalling the red arrow handles be sure that:
Since the handles can be pulled off, they could be accidentally reinstalled 180° from their correct orientation. To install the red arrow handles correctly, keep the handles pointed in the same direction as the arrows engraved on the control valve body while tightening the bypass valve caps. After completing and valve mainte- nance, press and hold NEXT and REGEN buttons for 3 seconds or unplug power source jack (black wire) and plug back in. The resets the electronics and establishes the service piston position. The display should fl ash all wording, then fl ash the software version (e.g. 181) and then reset the valve to the service position.

A. Electrical service to unit interrupted A. Assure permanent electrical service (check fuse, plug, pull chain,
B. Timer not working. B. Replace timer assembly.
C. Timer improperly set C. Check programming function
D. Safety brine valve not opening D. Replace safety brine valve
E. Salt “bridged” in brine tank E. Breakup salt
F. Meter not functioning F. Clean or replace as necessary
A. Bypass open A. Close bypass (replace if necessary)
B. Timer improperly set B. Increase frequency of regeneration
C. No salt in brine tank C. Add salt; maintain above water level
D. Excessive water usage D. Increase frequency of regeneration and/or salt setting (See HOW TO
E. Unit installed backwards E. Reinstall unit
F. Unit undersized F. Replace with larger unit
A. Brine valve not closing A. Replace brine valve
B. Salt setting too high B. Reset timer
C. Injector or Injector screen plugged C. Clean injector and screen
D. Drain line frozen, plugged or restricted D. Free drain
E. Salt “mushed” or sand from salt plugging bottom of
E. Clean out brine tank (see instructions)
F. Incorrect brine line fl ow control (BLFC) F. Replace with correct fl ow control (see specifi cations)
A. Timer improperly set A. Reset timer
A. Foreign material in control valve A. Remove piston assembly and inspect bore: remove foreign material
and check control in various regeneration positions
B. Internal control leak B. Replace seals and/or piston assembly
C. Control valve jammed in brine or backwash position C. Replace piston, seals and spacers
B. Cyclone distributor tube too short B. Replace
A. Installation of additional water treatment equipment such as
hardness or total dissolved solids (TDS)
reverse osmosis or demineralization
A. Iron build-up in line to water conditioner A. Clean line to water conditioner
B. Iron build-up in water conditioner B. Clean control and add Iron-X Mineral Cleaner to resin bed: increase
C. Well pumping sand C. Install sand trap
D. Pump losing capacity D. Contact pump repair service
A. Hydrogen sulfi de (“sulfur”) in water supply A. Install Sul-X Sulfur Reduction System
B. Bacterial iron in water supply B. Install Chem-Free Iron Reduction System
C. Algae in water supply C. Pour approximately 1/2 cup laundry bleach into brine well just
before regeneration as frequently as necessary
11 Loss of resin through drain A. Air in water system A. Assure that well system has proper air eliminator control: check for


NOTES: 1) The CFSM1254E softener conforms to NSF/ANSI Standard 44 for specifi c performance claims as verifi ed and substan- tiated by test data. Actual capacity may vary substantially depending on water analysis and operating conditions. 2) For satisfactory performance listed fl ow rate and duration should not be exceeded. Flow rates listed are adequate for normal applications. 3) The CFSM1254E softener is not intended to be used for treating water that is microbiologically unsafe or of un- known quality without adequate disinfection before or after the system. 4) All types of water softener salt may be used (see Mainte- nance.)
W x D x H, Inches 15 x 15 x 34
With Salt Grid Leg Extensions (required on salt settings above 18#) 135


Items Not Shown Description of Item Part Number Wrench V3193-01 Universal Elbow V3191-01 Retaining Clip H4615 Drain Line Insert PKP10TS8-BULK Drain Line Elbow Nut V3192 Drain Line Elbow 3158-01 Plumbing Adapter Kits 1” Brass Sweat V3007-02 1” Plastic Male NPT V3007-04 1.25” Plastic Male NPT V3007-05 1” Plastic Male BSP V3007-06


3 V3106-01 WS-1 Drive Bracket & Spring Clip 1
Not Shown V3168 WS1 AS Adapter 110V-12 V 1
Not Shown V3168-01 WS1 AC Adapter Cord Only 1
* Drawing number parts 2 through 6 may be purchased as a complete assembly, part V3002.


Section 7: PARTS COMPONENT PARTS LIST Drive Cap Assembly, Downfl ow Piston, Regenerant Piston and Spacer Stack Assembly




* The injector plug and the injector each contain one 011 (lower and 013 (upper) o-ring



Not Shown H4650 Elbow 1/2” with nut and insert Option
* Assembly includes V3182 BLFC. ** Includes drawing #7.

Proper BLFC orientation directs refill water flow towards the washer face with rounded edge and text.


7 V3162-032 DLFC 3.2 gpm for 3/4” One DLFC must be used if 3/4

Proper DLFC orientation directs water flow towards the washer face with rounded edge.


2 V3003 Meter Assembly (includes drawing #3 & #4) 1






Order No: V3007-05 Description: Fitting 1-1/4” Plastic Male NPT Assembly Order No: V3007-04 Description: Fitting 1” Plastic Male NPT Assembly






V3191-01 Vertical Adapter Assembly


Although no tools are necessary to assembly or disassemble the valve, the wrench (shown in various positions on the valve) may be purchased to aid in assembly or disassembly.

LIMITED WARRANTY For any warranty questions, please refer to the enclosed warranty card or call 1-800-222-7880 or mail your re- quest to:
CUNO Incorporated 400 Research Parkway Meriden, CT 06450, USA Toll Free: 1.888.218.CUNO
© 2009 3M Company. All rights reserved. 3M is a trademark of 3M Company. INSTR4330 0709
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| 1. Timer does not display time of day | A. AC Adapter unplugged | A. Connect power | p.14 |
| 1. Timer does not display time of day | B. No electric power at outlet | B. Repair outlet or use working outlet | p.14 |
| 1. Timer does not display time of day | C. Problem with AC Adapter | C. Replace AC Adapter | p.14 |
| 1. Timer does not display time of day | D. Problem with PC Board | D. Replace PC Board | p.14 |
| 2. Timer does not display correct time of day | A. Switched outlet | A. Use uninterrupted outlet | p.14 |
| 2. Timer does not display correct time of day | B. Power outage | B. Reset time of day | p.14 |
| 2. Timer does not display correct time of day | C. Problem with PC board | C. Replace PC board | p.14 |
| 3. No softening/fi ltering display when water is fl owing | A. Bypass valve in bypass position | A. Put bypass valve in service position | p.14 |
| 3. No softening/fi ltering display when water is fl owing | B. Meter connection disconnected | B. Connect meter to PC board | p.14 |
| 3. No softening/fi ltering display when water is fl owing | C. Restricted/stalled meter turbine | C. Remove meter and check for rotation or foreign material | p.14 |
| 3. No softening/fi ltering display when water is fl owing | D. Problem with meter | D. Replace meter | p.14 |
| 3. No softening/fi ltering display when water is fl owing | E. Problem with PC board | E. Replace PC board | p.14 |
| 4. Control Valve regenerates at wrong time of day | A. Power outages | A. Reset control valve to correct time of day | p.14 |
| 4. Control Valve regenerates at wrong time of day | B. Time of day not set correctly | B. Reset to correct time of day | p.14 |
| 4. Control Valve regenerates at wrong time of day | C. Time of regeneration incorrect | C. Reset regeneration time | p.14 |
| 5. ERROR followed by code number Error Code 1001 - Unable to recognize start of regeneration Error Code 1002 - Unexpected stall Error Code 1003 - Motor ran too long, timed out trying to reach next cycle position Error Code 1004 - Motor ran too long, timed out trying to reach home position If other Error Codes display, contact the factory | A. Control valve has just been serviced or unplug power source jack (black wire) and plug back in to reset control valve. | A. Press NEXT and REGEN for 3 seconds | p.14 |
| 5. ERROR followed by code number Error Code 1001 - Unable to recognize start of regeneration Error Code 1002 - Unexpected stall Error Code 1003 - Motor ran too long, timed out trying to reach next cycle position Error Code 1004 - Motor ran too long, timed out trying to reach home position If other Error Codes display, contact the factory | B. Foreign matter is lodged in control valve | B. Check piston and spacer stack assembly | p.14 |
| 5. ERROR followed by code number Error Code 1001 - Unable to recognize start of regeneration Error Code 1002 - Unexpected stall Error Code 1003 - Motor ran too long, timed out trying to reach next cycle position Error Code 1004 - Motor ran too long, timed out trying to reach home position If other Error Codes display, contact the factory | C. High drive forces on piston | C. Replace piston(s) and spacer stack assembly | p.14 |
| 5. ERROR followed by code number Error Code 1001 - Unable to recognize start of regeneration Error Code 1002 - Unexpected stall Error Code 1003 - Motor ran too long, timed out trying to reach next cycle position Error Code 1004 - Motor ran too long, timed out trying to reach home position If other Error Codes display, contact the factory | D. Control valve piston not in home position seconds | D. Press NEXT and REGEN for 3 seconds or unplug power source jack (black wire) and plug back in to reset control valve | p.14 |
| 5. ERROR followed by code number Error Code 1001 - Unable to recognize start of regeneration Error Code 1002 - Unexpected stall Error Code 1003 - Motor ran too long, timed out trying to reach next cycle position Error Code 1004 - Motor ran too long, timed out trying to reach home position If other Error Codes display, contact the factory | E. Motor not inserted fully to engage pinion, motor wires broken or disconnected, motor failure | E. Check motor and wiring. Replace motor if necessary | p.14 |
| 5. ERROR followed by code number Error Code 1001 - Unable to recognize start of regeneration Error Code 1002 - Unexpected stall Error Code 1003 - Motor ran too long, timed out trying to reach next cycle position Error Code 1004 - Motor ran too long, timed out trying to reach home position If other Error Codes display, contact the factory | F. Drive gear label dirty or damaged, missing or broken gear | F. Replace or clean drive gear | p.14 |
| 5. ERROR followed by code number Error Code 1001 - Unable to recognize start of regeneration Error Code 1002 - Unexpected stall Error Code 1003 - Motor ran too long, timed out trying to reach next cycle position Error Code 1004 - Motor ran too long, timed out trying to reach home position If other Error Codes display, contact the factory | G. Drive bracket incorrectly aligned to back plate | G. Reseat drive bracket properly | p.14 |
| 5. ERROR followed by code number Error Code 1001 - Unable to recognize start of regeneration Error Code 1002 - Unexpected stall Error Code 1003 - Motor ran too long, timed out trying to reach next cycle position Error Code 1004 - Motor ran too long, timed out trying to reach home position If other Error Codes display, contact the factory | H. PC board is damaged or problematic | H. Replace PC board | p.14 |
| 5. ERROR followed by code number Error Code 1001 - Unable to recognize start of regeneration Error Code 1002 - Unexpected stall Error Code 1003 - Motor ran too long, timed out trying to reach next cycle position Error Code 1004 - Motor ran too long, timed out trying to reach home position If other Error Codes display, contact the factory | I. PC board incorrectly aligned to drive bracket | I. Ensure PC board is correctly snapped on to drive bracket | p.14 |
| 6. Control valve stalled in regeneration | A. Motor not operating | A. Replace motor | p.14 |
| 6. Control valve stalled in regeneration | B. No electric power at outlet | B. Repair outlet or use working outlet | p.14 |
| 6. Control valve stalled in regeneration | C. Problem with AC Adapter | C. Replace AC Adapter | p.14 |
| 6. Control valve stalled in regeneration | D. Problem with PC board | D. Replace PC board | p.14 |
| 6. Control valve stalled in regeneration | E. Broken drive gear or drive cap assembly | E. Replace drive gear or drive cap assembly | p.14 |
| 6. Control valve stalled in regeneration | F. Broken piston retainer | F. Replace drive cap assembly | p.14 |
| 6. Control valve stalled in regeneration | G. Broken main or regenerant piston | G. Replace main or regenerant piston | p.14 |
| 7. Control valve does not regenerate automatically when “REGEN” button is depressed and held | A. AC Adapter unplugged | A. Connect AC Adapter | p.14 |
| 7. Control valve does not regenerate automatically when “REGEN” button is depressed and held | B. No electric power at outlet | B. Repair outlet or use working outlet | p.14 |
| 7. Control valve does not regenerate automatically when “REGEN” button is depressed and held | C. Broken drive gear or drive cap assembly | C. Replace drive gear or drive cap assembly | p.14 |
| 7. Control valve does not regenerate automatically when “REGEN” button is depressed and held | D. Problem with PC board | D. Replace PC board | p.14 |
| 8. Control valve does not regenerate automatically but does when “REGEN” button is depressed | A. Bypass valve in bypass position | A. Put bypass valve in normal operating position | p.14 |
| 8. Control valve does not regenerate automatically but does when “REGEN” button is depressed | B. Meter connection disconnected | B. Connect meter to PC board | p.14 |
| 8. Control valve does not regenerate automatically but does when “REGEN” button is depressed | C. Restricted/stalled meter turbine | C. Remove meter and check for rotation or foreign matter | p.14 |
| 8. Control valve does not regenerate automatically but does when “REGEN” button is depressed | D. Problem with meter | D. Replace meter | p.14 |
| 8. Control valve does not regenerate automatically but does when “REGEN” button is depressed | E. Problem with PC board | E. Replace PC board | p.14 |
| 8. Control valve does not regenerate automatically but does when “REGEN” button is depressed | F. Set-up error | F. Check control valve set-up procedure | p.14 |
| 9. Time of day fl ashes on and off | A. Power has been out more than two hours, the AC Adapter was unplugged and then plugged back into the wall outlet, the AC Adapter plug was unplugged and then plugged back into the board or the NEXT and REGEN but- tons were pressed to reset the valve | A. Reset the time of day | p.14 |
| 1. Hard water (unit not using salt; liquid level in brine tank NOT too high) | A. Electrical service to unit interrupted | A. Assure permanent electrical service (check fuse, plug, pull chain, or switch) | p.18 |
| 1. Hard water (unit not using salt; liquid level in brine tank NOT too high) | B. Timer not working. | B. Replace timer assembly. | p.18 |
| 1. Hard water (unit not using salt; liquid level in brine tank NOT too high) | C. Timer improperly set | C. Check programming function | p.18 |
| 1. Hard water (unit not using salt; liquid level in brine tank NOT too high) | D. Safety brine valve not opening | D. Replace safety brine valve | p.18 |
| 1. Hard water (unit not using salt; liquid level in brine tank NOT too high) | E. Salt “bridged” in brine tank | E. Breakup salt | p.18 |
| 1. Hard water (unit not using salt; liquid level in brine tank NOT too high) | F. Meter not functioning | F. Clean or replace as necessary | p.18 |
| 2. Hard water (unit using salt; liquid level in brine tank NOT too high) | A. Bypass open | A. Close bypass (replace if necessary) | p.18 |
| 2. Hard water (unit using salt; liquid level in brine tank NOT too high) | B. Timer improperly set | B. Increase frequency of regeneration | p.18 |
| 2. Hard water (unit using salt; liquid level in brine tank NOT too high) | C. No salt in brine tank | C. Add salt; maintain above water level | p.18 |
| 2. Hard water (unit using salt; liquid level in brine tank NOT too high) | D. Excessive water usage | D. Increase frequency of regeneration and/or salt setting (See HOW TO SET TIMER) | p.18 |
| 2. Hard water (unit using salt; liquid level in brine tank NOT too high) | E. Unit installed backwards | E. Reinstall unit | p.18 |
| 2. Hard water (unit using salt; liquid level in brine tank NOT too high) | F. Unit undersized | F. Replace with larger unit | p.18 |
| 3. Liquid level in brine tank TOO high | A. Brine valve not closing | A. Replace brine valve | p.18 |
| 3. Liquid level in brine tank TOO high | B. Salt setting too high | B. Reset timer | p.18 |
| 3. Liquid level in brine tank TOO high | C. Injector or Injector screen plugged | C. Clean injector and screen | p.18 |
| 3. Liquid level in brine tank TOO high | D. Drain line frozen, plugged or restricted | D. Free drain | p.18 |
| 3. Liquid level in brine tank TOO high | E. Salt “mushed” or sand from salt plugging bottom of brine tank | E. Clean out brine tank (see instructions) | p.18 |
| 3. Liquid level in brine tank TOO high | F. Incorrect brine line fl ow control (BLFC) | F. Replace with correct fl ow control (see specifi cations) | p.18 |
| 4. System regenerates at wrong time of day | A. Timer improperly set | A. Reset timer | p.18 |
| 5. Water continuously fl ows to drain | A. Foreign material in control valve | A. Remove piston assembly and inspect bore: remove foreign material and check control in various regeneration positions | p.18 |
| 5. Water continuously fl ows to drain | B. Internal control leak | B. Replace seals and/or piston assembly | p.18 |
| 5. Water continuously fl ows to drain | C. Control valve jammed in brine or backwash position | C. Replace piston, seals and spacers | p.18 |
| 6. Water tastes salty | A. Salt setting too high | A. Reset program cycle | p.18 |
| 6. Water tastes salty | B. Cyclone distributor tube too short | B. Replace | p.18 |
| 7. White spots on glassware and dark surfaces | A. Sodium residual resulting from water having very high hardness or total dissolved solids (TDS) | A. Installation of additional water treatment equipment such as reverse osmosis or demineralization | p.18 |
| 8. Low water pressure (low fl ow rate) | A. Iron build-up in line to water conditioner | A. Clean line to water conditioner | p.18 |
| 8. Low water pressure (low fl ow rate) | B. Iron build-up in water conditioner | B. Clean control and add Iron-X Mineral Cleaner to resin bed: increase frequency of regeneration | p.18 |
| 8. Low water pressure (low fl ow rate) | C. Well pumping sand | C. Install sand trap | p.18 |
| 8. Low water pressure (low fl ow rate) | D. Pump losing capacity | D. Contact pump repair service | p.18 |
| 9. “Rotten egg” smell (from hot water only) | A. Magnesium rod in water heater | A. Replace with aluminum rod or remove | p.18 |
| 10. “Rotten egg” smell (from both hot and cold water | A. Hydrogen sulfi de (“sulfur”) in water supply | A. Install Sul-X Sulfur Reduction System | p.18 |
| 10. “Rotten egg” smell (from both hot and cold water | B. Bacterial iron in water supply | B. Install Chem-Free Iron Reduction System | p.18 |
| 10. “Rotten egg” smell (from both hot and cold water | C. Algae in water supply | C. Pour approximately 1/2 cup laundry bleach into brine well just before regeneration as frequently as necessary | p.18 |
| 11 Loss of resin through drain | A. Air in water system | A. Assure that well system has proper air eliminator control: check for dry well condition | p.18 |