Instruction/ maintenance manual of the product DVF-36S-N Design Dynamics
Go to page of 36
For more information, visit www .desatech.com W ARNING: If the information in this manual is not fol- lowed exactly , a re or explosion may result causing property damage, personal injury or loss of life. — Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
www .desatech.com 120441-01A 2 SAFETY INFORMA TION T ABLE OF CONTENTS Safety Information ............................................... 2 Product Identication ........................................... 4 Local Codes...............................
www .desatech.com 120441-01A 3 Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the u, with headaches, dizziness or nausea. If you have these signs, the replace may not be working properly . Get fresh air at once! Have replace serviced.
www .desatech.com 120441-01A 4 3. Never install the replace • in a recreational vehicle • in windy or drafty areas where curtains or othe r comb usti ble (a mmab le) obj ect s can make contact with the fireplace front • in high trafc areas 4.
www .desatech.com 120441-01A 5 Figure 2 - Common Fireplace Locations Flush with a wall Through exterior wall enclosed in a chase Corner installation • T his repla ce may be in stal led in an y r oom of you r house provid ed all local cod es and thes e in stal lati on i nstr uctio ns a re f ollo wed.
www .desatech.com 120441-01A 6 CLEARANCES Min imum cle ara nce s to comb ustib les for the r ep la ce a re as fo ll ow s: *Back and sides 0" Perpendicular walls 6" Floor 0" Ceiling to louver opening 42" Front 36" T op of Standoffs 0" V ent (See venting instructions for specic ve nt in g cl ea ra nc es .
www .desatech.com 120441-01A 7 Fixed Closed Op en ab le Fixed Closed V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION CAP AIR SUPPL Y INLET GAS METER RESTRICTED AREA (TERMINA TION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony [*12" (30.
www .desatech.com 120441-01A 8 VENT ING INST ALLA TION NOTICE: Read these instruc - t i o n s c o m p l e t e l y b e f o r e a t - tempting installation. These models are tested and approved for use with DESA (direct vent) pipe components and terminations.
www .desatech.com 120441-01A 9 INST ALLA TION PLANNING Th e re a re tw o ba s ic ty p es of d ir e ct ve n t installation: • Horizontal T ermination • V ertical T ermination Outside air ex installation is required for both horizontal and vertical installation (see page 13).
www .desatech.com 120441-01A 10 VENTING INST ALLA TION Continued W ARNING: Do not recess vent termination into any wall. This will cause a re hazard. 5. Noncombu stible Exter ior Wal l: Position the horizontal vent cap in the center of the 8 1 / 2 " round hole and attach to the exterior wall with four wood screws provided.
www .desatech.com 120441-01A 1 1 2' Min. 2' Pipe Min. + 90° Elbow 7' Min. VENTING INST ALLA TION Continued Figure 13 - T ypical Horizontal T ermination Cap Mounting with Additional Sid.
www .desatech.com 120441-01A 12 V ertical T ermination Installation Note: V ertical restrictor must be installed in all vertical installations. 1. Determine the route your vertical venting will take.
www .desatech.com 120441-01A 13 5. Place the ashin g over the pipe sectio n(s) extending through the roof. Secure the base of the ashing to the roof and fram - ing with roong nails. Be sure roong material overlaps the top edge of the ashing as shown in Figure 16, page 12.
www .desatech.com 120441-01A 14 P ARTS LIST FOR VENTING KITS AND COMPONENTS DE SA ( 5"/ 8" ) Pip e & V en t Kit s Number Description P58-6 6" Section Double W all Pipe, Galvanized P.
www .desatech.com 120441-01A 15 For propane/LP connection only , the installer must supply an external regulator . The exter- nal regulator will reduce incoming gas pres- sure. Y ou must reduce incomin g gas pressur e to between 1 1" and 14" of w .
www .desatech.com 120441-01A 16 FIREPLACE INST ALLA TION Continued CONNECTING FIREPLACE TO GAS SUPPL Y Installation Items Needed • 5/16" hex socket wrench or nut-driver • sealant (resistant to propane/LP gas, not provided) 1. Route exible gas line (provided by in - staller) from equipment shutoff valve to replace.
www .desatech.com 120441-01A 17 FIREPLACE INST ALLA TION Continued Figure 24 - Checking Gas Joints for Propane/LP Gas Fireplace Pr op ane /L P Su pp ly T an k Gas V alve Equipment Shutoff V alve Figure 25 - Checking Gas Joints for Natural Gas Fireplace Gas Meter Gas V alve Equipment Shutoff V alve PRESSURE TESTING FIREPLACE GAS CONNECTIONS 1.
www .desatech.com 120441-01A 18 Removing and Installing Inner Door Inner door is factory installed. 1. Open outer door . Secure door in open position to avoid accidental breakage. 2 . Remove middle door by lifting from hinges (see Figure 26). Set aside to avoid scratches or damage.
www .desatech.com 120441-01A 19 Lock Unlock FIREPLACE INST ALLA TION Continued Figure 27 - Removing/Installing Brick, Side Trim and Screen Figure 28 - Removing/Installing Inner Door Side T rim Side T .
www .desatech.com 120441-01A 20 Figure 32 - Installing the WRC Remote Receiver Fireplace Receptacle Remote Control Receiver Extension Cord Ignition Module Plug W ALL SWITCH INST ALLA TION Installation of a wall switch allows you to activate gas control valve and turn replace on and off.
www .desatech.com 120441-01A 21 WIRING DIAGRAM EV2 EV1 ORANGE IGNITOR LEAD GREEN PILOT TRANSFORMER IS1070B SYNETEK CONTROLS INC 24V AC E4 E2 E3 E6 RED E8 E12 BLUE 120V AC GROUND 120 V AC ADAPTER/ REMOTE RECEIVER J-BOX BLACK WHITE OPERA TION C. Do not use this applianc e if any part has been und er wate r .
www .desatech.com 120441-01A 22 6. Wait ve (5) minutes to clear out any gas. Then smell for gas, includin g near the oor. If you smell gas, STOP! Fol - low “B” in the safety information on page 21. If you don't smell gas, go to the next step.
www .desatech.com 120441-01A 23 Figure 37 - T ypical Flame Pattern Fi gu re 37 shows a typical ame pattern. If burner ame pattern differs from that de - scribed: • turn replace off (see T o.
www .desatech.com 120441-01A 24 W AR N I N G : Do no t op er at e r e - pl ace wit h gla ss do or u nla tc hed , re mov ed , c rac ke d o r bro ken . PILOT AND BURNERS • Remove material before cleaning burners and replace when cleaning is complete.
www .desatech.com 120441-01A 25 TROUBLESHOO TING W ARNING: T urn off replace and let cool before servicing. Only a qualied service person should service and repair replace. CAUTION: Never use a wire, needle or similar object to clean pilot. This can damage pilot unit.
www .desatech.com 120441-01A 26 OBSERVED PROBLEM Pilot will not stay lit No gas to burner , although wall switch and valve are set to the ON position Frequent pilot outage Fireplace produces a clicking/ ticking noise just after burner is lit or shut off Slight smoke or odor during initial operation REMEDY 1.
www .desatech.com 120441-01A 27 TROUBLESHOO TING Continued W ARNING: If you smell gas • Shut off gas supply . • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone.
www .desatech.com 120441-01A 28 10 14 9 7 21 1 1 32 23 24 26 25 41 8 22 15 16 17 18 19 33 34 20 30 13 40 2 1 3 27 31 38 37 4 29 28 12 6 43 42 35 36 39 ILL USTRA TED P ARTS BREAKDOWN MODELS DVF-36S-N, .
www .desatech.com 120441-01A 29 P ARTS LIST This list contains replaceable parts used in your replace. When ordering parts, follow the instructions listed under Replacement Parts on page 24 of this manual.
www .desatech.com 120441-01A 30 ILL USTRA TED P ARTS BREAKDOWN BURNER ASSEMBL Y FOR MODELS DVF-36S-N, DVF-36S-P , DVF-36H-N, DVF-36H-P , DVF-36SC-N, DVF-36SC-P , DVF-36HC-N, DVF-36HC-P 23 1 22 32 37 1.
www .desatech.com 120441-01A 31 KEY NO. P ART NO. DESCRIPTION QTY . 1 ** Bottom Pan Weldment • • 1 2 120402-01 Burner Plate Weldment • • 1 3 120637-01 Log Bracket • 2 4 120405-01 Right Brack.
www .desatech.com 120441-01A 32 ILL USTRA TED P ARTS BREAKDOWN REFRACTOR Y P ARTS FOR MODELS DVF-36S-N, DVF-36S-P , DVF-36H-N, DVF-36H-P , DVF-36SC-N, DVF-36SC-P , DVF-36HC-N, DVF-36HC-P 14 20 15 19 1.
www .desatech.com 120441-01A 33 KEY NO. P ART NO. DESCRIPTION QTY . 1 102520-01 Refractory Retainer • • • • • • • • 2 2 120248-01 Left Refractory • • • • 1 120449-01 Left Refra.
www .desatech.com 120441-01A 34 _____________________________________________________ ______________________________________________________ ______________________________________________________ ____.
www .desatech.com 120441-01A 35 _____________________________________________________ ______________________________________________________ ______________________________________________________ ____.
Desa Heating, LLC 2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com NOT A UPC 120441-01 Rev . A 02/07 WARRANTY INFORMA TION KEEP THIS WARRANTY Model ______________________________ Serial No.
An important point after buying a device Design Dynamics DVF-36S-N (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Design Dynamics DVF-36S-N yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Design Dynamics DVF-36S-N - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Design Dynamics DVF-36S-N you will learn all the available features of the product, as well as information on its operation. The information that you get Design Dynamics DVF-36S-N will certainly help you make a decision on the purchase.
If you already are a holder of Design Dynamics DVF-36S-N, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Design Dynamics DVF-36S-N.
However, one of the most important roles played by the user manual is to help in solving problems with Design Dynamics DVF-36S-N. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Design Dynamics DVF-36S-N along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center