EN
Desa logo
Official user manual

Desa VP324E

28 pages·4.1 MB·Outdoor Fireplace·PDF·ENDEFRITNLJA
Desa VP324E
Table of Contents 20 sections Table of Contents · Safety information · UNPACKING · INTRODUCTION · … ShowHide
Page 1 of the Desa VP324E user manual — NOT FOR USE WITH SOLID FUEL
Page 1 · click to enlarge
Page 1
Desa VP324E diagram (page 1)
Fig. 1

B-VENT DECORATIVE GAS FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUAL

For more information, visit www.desatech.com For more information, visit www.desatech.com

MODELS P324E, VP324E, P325E(B) AND VP325E(B)

NATURAL GAS

SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appli- ance, it also contains information that will enable you to obtain replacement parts or optional accessory items when needed. Keep it with your other important papers.

FOR YOUR SAFETY — Do not store or use gasoline or any other flam-

mable vapors or liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS :

  • Do not try to light any appliance.
  • Do not touch any electrical switch;
  • Do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a

NOT FOR USE WITH SOLID FUEL

CHECK LOCAL CODES PRIOR TO

INSTALLATION

qualified installer, service agency, or the gas supplier.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.

Save this manual for future reference. Save this manual for future reference.

Page 3 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 3 · click to enlarge
Page 3
Desa VP324E — UNPACKING diagram (page 3)
Fig. 2

SAFETY INFORMATION Continued

UNPACKING

  • The following items are packed inside the firebox. Remove before positioning firebox into framing.
  • Ceramic Log Pack - Shrink-wrapped on cardboard
  • Three (3) plastic bags containing lava rock, pan and ember materials
  • Rear Log (P325E/VP325E Models Only) - Remove the two plastic quick ties from around the burner and grate
  • Grate Stand - Lift off of burner pan

8. Turn fireplace off and let cool before servicing or repairing. Only a qualified service person should install, service, or re- pair this fireplace. Have fireplace inspected annually by a quali- fied service person. 9. You must keep control compartments, burners, and circulating air passages clean. More frequent cleaning may be needed due to excessive lint and dust from carpeting, bedding material, etc. Turn off the gas valve and pilot light before cleaning fireplace. 10. Have venting system inspected annually by a qualified service person. If needed, have venting system cleaned or repaired. See Cleaning and Maintenance, page 17. 11. Keep the area around your fireplace clear of combustible ma- terials, gasoline, and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around fireplace. 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fireplace nameplate. 14. This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Ca- nadian Electrical Code, CSA C22.1. 15. Do not install fireplace directly on carpeting, vinyl tile, or any com- bustible material other than wood. The fireplace must set on a metal or wood panel extending the full width and depth of the fireplace. 16. Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service person to arrange for replacement of the unit. 17. Do not operate fireplace if any log is broken. 18. Do not use a blower insert, heat exchanger insert, or other ac- cessory not approved for use with this fireplace.

Check all items for any shipping damage. If damaged, promptly inform dealer or distributor where you bought the product.

Safely retain these items for later installation.

For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 4 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 4 · click to enlarge
Page 4
Desa VP324E — INTRODUCTION diagram (page 4)
Fig. 3

INTRODUCTION

These fireplace models are vented gas fireplaces that use an elec- tronic gas control valve and electronic ignition system. P325E/ VP325E models have a 5" B-vent and P324E/VP324E models have a 4" B-vent. A properly sized B-Type venting system and a listed type vent cap are not supplied but are required for proper operation. See venting instructions on pages 8 and 9.

The installation must conform with local codes or, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1 or with the current CAN/CSA B149 Installation Codes.

This appliance complies with ANSI Z21.50-2000 and CSA 2.22- 2000 as Vented Gas Fireplaces and is listed and tested by the Canadian Standards Association to the above test standards.

These models are factory equipped for use with natural gas and must be converted when intended for use with propane/LP gas. Conversion kits PCBE-324 and PCBE-325 may be purchased for simple conver- sion to propane/LP gas. See Accessories, page 21.

BEFORE YOU BEGIN

Before beginning the installation of your appliance, read these instructions through completely.

This DESA appliance and its approved components are safe when installed according to this installation manual and are operated as recommended by DESA. Unless you use DESA approved components tested for this appliance, YOU MAY CAUSE A FIRE HAZARD!

The appliance and it’s individual shutoff valve must be discon- nected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

The DESA warranty will be voided by, and DESA disclaims any responsibility for the following actions : A) Modification of the appliance or any of the components. B) Use of any component part not approved by DESA in combi- nation with this appliance. C) Installation and/or operation in a manner other than instructed in this manual. D) The burning of anything other than the type of gas approved

The appliance must be isolated from the gas supply piping system by closing its individual equipment shutoff valve during any pres- sure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

For the purpose of input adjustment two pressure taps (for IN and OUT pressures) are provided on the gas control valve for test gauge connections to the appliance.

for use in this gas appliance.

GAS RATING - NATURAL P324E, VP324EP325E(B), VP325E(B) Max. Input Rating:15,000 Btu/Hr25,000 Btu/Hr Manifold Pressure:3.5 in. WC (.87 kPa)3.5 in. WC (.87 kPa) Minimum Supply Pressure:4.5 in. WC (1.12 kPa)4.5 in. WC (1.12 kPa) Maximum Supply Pressure:10.5 in. WC (2.66 kPa)10.5 in. WC (2.66 kPa) Orifice Size:# 49# 40 GAS RATING - PROPANE/LP Max. Input Rating:15,000 Btu/Hr25,000 Btu/Hr Manifold Pressure:10.0 in. WC (2.49 kPa)10.0 in. WC (2.49 kPa) Minimum Supply Pressure:11.0 in. WC (2.74 kPa)11.0 in. WC (2.74 kPa) Maximum Supply Pressure:13.0 in. WC (3.23 kPa)13.0 in. WC (3.23 kPa) Orifice Size:# 56# 54

For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 5 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 5 · click to enlarge
Page 5
Desa VP324E — product specifications diagram (page 5)
Fig. 4 · product specifications

PRODUCT SPECIFICATIONS

21 1/2"

Desa VP324E — PRODUCT SPECIFICATIONS diagram (page 5)
Fig. 5

* 13 3/4" 14 1/2"

2 1/2" 8 1/4"

35 3/8" 29 1/2"

7 5/8" 10 5/8"

Figure 1 - Appliance Dimensions

SELECTING LOCATION

To determine the safest and most efficient location for your appli- ance, you must take into consideration the following guidelines: 1. The location must allow for proper clearances (see Clear- ances, page 6). 2. Consider a location where heat output would not be affected by drafts, air conditioning ducts, windows, or doors. 3. A location that avoids the cutting of joists or roof rafters will make installation easier. Figure 2 shows a plan view of a few common locations.

Internal wall installations provide a discreet option for room separation and can also be ideal as an addition to an existing wall.

Desa VP324E — SELECTING LOCATION diagram (page 5)
Fig. 6

Flush installations are recommended where living space is limited or at a premium, and since the space required to enclose the appliance would be located beyond an outside wall, this would also reduce the cutting of joists, roof rafters, and such. Check local codes for any restrictions.

Projected installations can extend any distance into the room. A projection may be ideal for a new addition on an existing, finished wall.

Figure 2 - Possible Locations for Installing Appliance

Corner installations make use of space that may not normally be used and provides a wider and more efficient range for radiant heat transference.

For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 6 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 6 · click to enlarge
Page 6
Desa VP324E — Pre-Installation Preparation diagram (page 6)
Fig. 7 · Pre-Installation Preparation

PRE-INSTALLATION PREPARATION

CLEARANCES

MANTEL CLEARANCES AND WALL DETAILS

A combustible mantle shelf maybe installed a maximum 12" (229mm) from the wall. Figures 5 and 6 show the minimum allowable distances from various combustible mantle components in relation to the fireplace opening.

  • Minimum clearances to combustibles are:
  • Top of Spacers........................................................... 0" min.
  • Back and Sides of Outer Surround............................ 0" min.
  • Drywall to Sides of Front Face (Nailing Flanges) ... 0" min.
  • “B” Vent Surfaces ..................................................... 1" min.
  • Ceiling to Opening .................................................. 42" min.
  • Floor .......................................................................... 0" min.
  • Perpendicular Wall ............................................See Figure 6
Desa VP324E — CLEARANCES diagram (page 6)
Fig. 8

2 x 4 Stud

Desa VP324E — CLEARANCES diagram (page 6)
Fig. 9

Figure 5 - Mantel Clearances - Side View (Cross Section)

Figure 3 - Minimum Clearances (Top View)

1" (25mm) Min. Clearance to "B" Vent’s Outer Pipe

Desa VP324E — CLEARANCES diagram (page 6)
Fig. 10

1 1/2" (38mm) Max. 3" (76mm) Max.

Required Air Spaces are Indicated with an "*". Do Not Pack with Insulation or Any Other Material DO NOT BLOCK

Figure 6 - Side Clearances - Top View (Cross Section)

For more information, visit www.desatech.com For more information, visit www.desatech.com

Left Side Surround · Front Face · Drywall

Page 7 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 7 · click to enlarge
Page 7
Desa VP324E — Pre-Installation Preparation diagram (page 7)
Fig. 11 · Pre-Installation Preparation

PRE-INSTALLATION PREPARATION Continued

FRAMING 1. Frame appliance enclosure as illustrated in Figures 7 and 8. Note: If a wall covering is used to line the enclosure, then all measurements must be from the surface of the covering. 2. Place the appliance into the framing and secure it. Note: If appliance is to be raised above floor level, a platform must be built to support the appliance. 3. Install the supply line to the appliance using a 1/2" NPT black iron gas line terminating 2 5/16" above the bottom of the appli- ance. The gas line may be installed from either side or from the rear of the appliance (see Figure 16, page 11). 4. Feed flexible gas line through one of three gas line conduit sleeve and repack insulation to cover any openings. Prepare the incoming gas line with teflon tape or pipe joint compound and hook-up incoming gas line to the flexible gas line. Note: If 1/2" NPT black iron pipe does not mate with fitting at the end of flexible gas line, remove fitting and replace with a 37 degree flare 3/4"-12, 1/2" NPT (female) fitting.

These Dimensions Allow for a 3/4" Clearance at Sides and Back of Fireplace. However, 0" Clearance is Permitted

Desa VP324E — PRE-INSTALLATION PREPARATION Continued diagram (page 7)
Fig. 12 · PRE-INSTALLATION PREPARATION Continued

3/4" Clearance Not Required at Nailing Flanges

Figure 8 - Corner Installation Guidelines

Desa VP324E — PRE-INSTALLATION PREPARATION Continued diagram (page 7)
Fig. 13 · PRE-INSTALLATION PREPARATION Continued

Figure 7 - Rough Opening for Installing in Wall

For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 8 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 8 · click to enlarge
Page 8
Desa VP324E — Venting INSTALLATION diagram (page 8)
Fig. 14 · Venting INSTALLATION

VENTING INSTALLATION

A B-type venting system must be connected to the appliance for venting to the outside of the building.

Example 1: Shows the minimum allowable system height and lateral offset for a 60° degree or greater inclination. Code specifies that offsets at 60° degrees or greater are considered horizontal and must follow the 75% percent rule for lateral to total vertical system height. Codes also allows only one offset in the total system when at 60° degrees or greater. The total vertical height in this example represents the minimum height of 8 feet and therefore the allowable lateral is 6 feet when the 75% percent rule applies. If the lateral length must exceed 75% then the system must be sized in accor- dance with the Category I venting tables.

The following section is provided as a guide to a standard B-type vent installation.

Standing codes requirements concerning B-type vent installations may vary within your state, province or local codes jurisdiction. Therefore, it is recommended that you check with your local building codes for specific requirements or in absence of local codes, follow Section 7.0 of the current National Fuel Gas Code NFPA No. 54/ANSI Z223.1 and in Canada with CAN/CSA B149 for Category I systems using double wall B-1 vent pipe.

Example 2: Shows a multiple offset each at 45° degrees of inclination. Multiple offsets are permitted if they do not exceed 60° degrees of inclination. The total lengths of the two offsets are not required to meet the 75% percent allowable rule.

This gas appliance must be vented to the outdoors only and may not be terminated into an attic space or into a chimney flue servicing a solid-fuel burning appliance.

Example 3: Shows a single offset at 45° degrees of inclination and therefore the lateral length at 10 feet of offset does not have to meet the 75% percent rule.

This appliance may be vented through a manufactured chimney system or a masonry chimney using a B-vent adapter or a chimney liner system if all are listed, inspected and approved by local codes and/or building authorities.

In each case the offsets must be supported and firestops must be positioned wherever the vent must pass through a sub-floor, ceiling joist or an attic overhang. The vent pipe must terminate vertically into a listed type vent cap and extend a sufficient height through an approved roof flashing, roof jack or a roof thimble. At all points the listed clearances must be maintained.

The examples shown in Figure 9 are typical of most B-vent installations and codes practices.

Desa VP324E — VENTING INSTALLATION diagram (page 8)
Fig. 15

Support Each Lateral At Least Every Six (6) Feet

EXAMPLE 3 EXAMPLE 2 EXAMPLE 1

Figure 9 - Typical B-Vent Configuration

For more information, visit www.desatech.com For more information, visit www.desatech.com

Listed Vent Cap

Page 9 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 9 · click to enlarge
Page 9
Desa VP324E — Venting INSTALLATION diagram (page 9)
Fig. 16 · Venting INSTALLATION

VENTING INSTALLATION Continued

Vent terminations must be located in accordance with height and proximity rules of NFPA No. 54 or CAN/CSA B149. These rules apply to vents at 12 in. diameter or less and require a minimum height in accordance with the roof pitch and a minimum of 8 ft. distance from a vertical wall or obstruction (see Figure 10).

Desa VP324E — VENTING INSTALLATION Continued diagram (page 9)
Fig. 17 · VENTING INSTALLATION Continued

If venting horizontally through a side wall becomes necessary, a listed thimble approved for use with B-type vent must be used. Check with your local codes before venting through a side wall.

Some codes areas allow the use of existing B-type vent systems if the system is at or above the recommended diameter of the flue.

CHECKING FOR PROPER VENTING

The flue connection must be made using listed B-type connectors and the existing system must be code inspected for damage and proper installation.

After completing and checking the electrical, gas and vent connec- tions, follow the lighting instructions and allow the main burner to run for approximately 5 minutes. Hold a lighted match or cigarette near the top edge of the fireplace opening and play it along the entire length of the opening (see Figure 11). Proper venting should tend to draw the flame or smoke into the appliance. Improper venting or escaping of spillage of burned gas, is indicated when the match flickers or goes out. Smoke from a cigarette will also tend to disperse away from the appliance.

It is not recommended that this appliance be common vented with an existing gas burning appliance. However, if it becomes necessary to common vent this appliance, the venting system must be sized and configured in accordance with the common venting guides Appendix G of the current National Fuel Gas Code NFPA No. 54/ ANSI Z223.1 and in Canada with CAN/CSA B149.

If the appliance is found to be improperly venting, shut it off and notify your installer or a qualified service agency to inspect the venting system.

Desa VP324E — CHECKING FOR PROPER VENTING diagram (page 9)
Fig. 18
Desa VP324E — CHECKING FOR PROPER VENTING diagram (page 9)
Fig. 19

Check this area along the entire top edge of the fireplace opening. Smoke or flame should be drawn into the appliance opening.

Desa VP324E — CHECKING FOR PROPER VENTING diagram (page 9)
Fig. 20

Flat to 6/12 1.0 0.30 6/12 to 7/12 1.25 0.38 Over 7/12 to 8/12 1.5 0.46 Over 8/12 to 9/12 2.0 0.61 Over 9/12 to 10/12 2.5 0.76 Over 10/12 to 11/12 3.25 0.99 Over 11/12 to 12/12 4.0 1.22 Over 12/12 to 14/12 5.0 1.52 Over 14/12 to 16/12 6.0 1.83 Over 16/12 to 18/12 7.0 2.13 Over 18/12 to 20/12 7.5 2.27 Over 20/12 to 21/12 8.0 2.44

Figure 10 - B-Vent Terminations

Figure 11 - Checking for Spillage

For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 10 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 10 · click to enlarge
Page 10
Desa VP324E — Installation diagram (page 10)
Fig. 21 · Installation

Wall Switch Installation Optional Remote Control Installation (Model WRC) Gas Line Hook-Up

INSTALLATION

WALL SWITCH INSTALLATION

Desa VP324E — WALL SWITCH INSTALLATION diagram (page 10)
Fig. 22

The installation of a wall switch allows you to activate the gas control valve and turn the fireplace on and off. The wall switch is to be connected to the incoming 120 volt regular household wiring that supplies the electricity to the fireplace. Refer to wiring diagram in this manual on page 18.

OPTIONAL REMOTE CONTROL INSTALLATION (Model WRC)

Note: If using optional wireless hand-held remote control, the wall switch must be in the ON position to be operational. The remote control then becomes the switching mechanism for fireplace operation. 1. Remove the front refractory access panel by lifting up and an- gling out of the firebox opening (see Figure 12). 2. The WRC model receiver does not require a battery. The re- ceiver can be installed by first plugging the short extension cord into the fireplace receptacle. Then plug the receiver unit into the extension cord. Finally plug the ignition module plug into the receiver unit (see Figure 13). 3. Activate the remote handset battery by removing the insulat- ing tab on the back of the handset (see Figure 14). The battery is included pre-installed. 4. Once the battery is activated the unit is ready to use. 5. Replace front refractory access panel.

Figure 14 - Installing Battery into Back of Handset

Desa VP324E — OPTIONAL REMOTE CONTROL INSTALLATION (Model WRC) diagram (page 10)
Fig. 23 · OPTIONAL REMOTE CONTROL INSTALLATION (Model WRC)

A equipment shutoff valve has been included in the appliance’s gas supply system. You may consider installing an extra gas shutoff valve outside the appliance’s enclosure (check with local codes) where it can be accessed more conveniently with a key through a wall as shown in Figure 15.

Typical Exterior Wall Gas Shutoff Installation

Figure 15 - Equipment Shutoff Valve Installation

Figure 12 - Removing Front Refractory Access Panel (P325E/VP325E Model Shown)

For more information, visit www.desatech.com For more information, visit www.desatech.com

Shutoff Valve · Key · Extension

Page 11 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 11 · click to enlarge
Page 11
Desa VP324E — Installation diagram (page 11)
Fig. 24 · Installation

INSTALLATION Continued

In conformance with local codes, route a 1/2" NPT gas line towards the appliance coming in from any of the 3 directions shown in Figure 16.

Incoming 1/2" Gas Line Permitted by Local Codes

Sediment Trap (Not Supplied)

Side Wall Of Appliance

3" Min. (76mm)

1/2" NPT Incoming Black Iron Gas Line Flexible Gas Line (1 Provided) Can Be Extended Out Either Side

Desa VP324E — INSTALLATION Continued diagram (page 11)
Fig. 25 · INSTALLATION Continued

Red Surface Indicates For Propane/LP Use Only

Desa VP324E — INSTALLATION Continued diagram (page 11)
Fig. 26 · INSTALLATION Continued

8 3/8" 10 5/8"

Alternate Gas Supply Through Sub-Floor

1/2" NPT Incoming Gas Line Inlet Pressure Tap Outlet Pressure Tap

Figure 16 - Routing Incoming Gas Line

DESA recommends that a black iron gas line be routed from the gas source, through a sediment trap (shown in Figure 17), and into the appliance, Once connected through the appliance, a flexible gas line may be used for ease of installation to gas control valve (see Figure 18).

Figure 18 - Connecting Flexible Gas Line to Millivolt Valve

Before connecting the black iron gas line to the inside of the appliance a sediment trap must be included outside the appliance between the gas line and the gas shutoff valve. It must extend down three (3) inches beyond the center of the pipe. Prepare incoming black iron gas line with teflon tape or pipe joint compound (Check with local building codes).

WARNING: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply a noncor- rosive leak detection fluid to all connections and joints. If bubbles appear, leaks can be detected and corrected. Do not use an open flame for leak testing and do not operate any appliance if a leak is detected.

Complete your gas installation by connecting incoming gas line with flexible gas line. Secure tightly with wrench but DO NOT OVERTIGHTEN.

For more information, visit www.desatech.com For more information, visit www.desatech.com

Figure 17- Sediment Trap

Page 12 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 12 · click to enlarge
Page 12
Desa VP324E — Installation diagram (page 12)
Fig. 27 · Installation

Ember and Pan Material Placement Log Placement for P324E/VP324E Models

INSTALLATION Continued

EMBER AND PAN MATERIAL PLACEMENT 1. Open the bag(s) of vermiculite and fill the entire burner pan until the burner tube is completely covered (see Figure 19). 2. Smooth the pan material just even with edges of the burner pan. 3. Remove the ember material from the bag and flatten small amounts into quarter size pieces and lay on top of the surface of the pan material (see Figure 20). 4. Place just enough to cover the entire surface and leave about a 1/2 inch gap under the lower grate members to allow air to flow (see Figure 21).

LOG PLACEMENT FOR P324E/VP324E MODELS 1. Place front (log 1) onto front of grate sliding log all the way forward against grate fingers (see Figure 22). 2. Insert pegs on bottom of rear log (log 2) into holes in rear of grate (see Figure 22). 3. Insert pegs on back of log 3 into right hole on log 1 and right hole of log 2 (see Figure 23). 4. Insert pegs on back of log 4 into left hole on log 1 and left hole of log 2 (see Figure 23).

To enhance the look of the hearth you may optionally place the lava rock provided around the front and sides of the burner.

Desa VP324E — INSTALLATION Continued diagram (page 12)
Fig. 28 · INSTALLATION Continued
Desa VP324E — INSTALLATION Continued diagram (page 12)
Fig. 29 · INSTALLATION Continued

Figure 19 - Fill Entire Burner Pan with Vermiculite (P325E/ VP325E Model Shown)

Ember Material Burner Pan Vermiculite (Pan Material) Grate

Desa VP324E — INSTALLATION Continued diagram (page 12)
Fig. 30 · INSTALLATION Continued

Figure 22 - Installing Logs 1 and 2

Figure 20 - Ember Material on Surface of Pan Material (Vermiculite) (P325E/VP325E Model Shown)

Desa VP324E — INSTALLATION Continued diagram (page 12)
Fig. 31 · INSTALLATION Continued
Desa VP324E — INSTALLATION Continued diagram (page 12)
Fig. 32 · INSTALLATION Continued

Figure 21 - Pan and Ember Material Clearances (P325E/VP325E Model Shown)

Figure 23 - Installing Logs 3 and 4

For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 5 more labels / short text on this page
Burner Pan Grate · Vermiculite (Pan Material) · Log 4 · Log 3 · Burner Pan
Page 13 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 13 · click to enlarge
Page 13
Desa VP324E — Installation diagram (page 13)
Fig. 33 · Installation

INSTALLATION Continued

LOG PLACEMENT FOR P325E(B)/VP325E(B) MODLES 1. Place large back log (log 1) onto grate making sure notches rest over grate (see Figure 24). 2. Place log 2 onto front right side of grate. Gently insert peg on back of log 2 into hole on right front of log 1 (see Figure 24). 3. Insert peg on back of log 3 into hole on left front of log 1 (see Figure 25). Log 3 will rest between first two grate fingers on left of grate assembly (see Figure 25)

4. Insert peg on back of log 4 into hole on top left of log 1. Rest the front of log 4 on the grate as shown in Figure 26. 5. Insert peg on back of log 5 into hole on the top right of log 1 (see Figure 26). Rest the bottom of log 5 on grate as shown in Figure 27.

To enhance the look of the hearth you may optionally place the lava rock provided around the front and sides of the burner.

Desa VP324E — INSTALLATION Continued diagram (page 13)
Fig. 34 · INSTALLATION Continued
Desa VP324E — INSTALLATION Continued diagram (page 13)
Fig. 35 · INSTALLATION Continued
Desa VP324E — INSTALLATION Continued diagram (page 13)
Fig. 36 · INSTALLATION Continued

Figure 24 - Installing Logs 1 and 2

Desa VP324E — INSTALLATION Continued diagram (page 13)
Fig. 37 · INSTALLATION Continued

Figure 26 - Installing Logs 4 and 5

Desa VP324E — INSTALLATION Continued diagram (page 13)
Fig. 38 · INSTALLATION Continued

Figure 25 - Installing Log 3

Figure 27 - Logs Installed

For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 4 more labels / short text on this page
Log 5 · Log 2 · Log 1 · Log 1
Page 14 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 14 · click to enlarge
Page 14
Desa VP324E — Installation diagram (page 14)
Fig. 39 · Installation

Combustion Air Kit Model AK4 (Optional) Appliance Enclosure Installing Optional Glass Door Accessory

INSTALLATION Continued

COMBUSTION AIR KIT MODEL AK4 (OPTIONAL)

INSTALLING OPTIONAL GLASS DOOR ACCESSORY

The outside air kit may be installed on the left side of the fireplace only. The vent can be installed through the outside wall or a ventilated crawl space. The handle to operate the damper door for the outside air inlet will be located inside the left “screen pocket” of the firebox (see Figure 28). Pull the handle to open or push to close.

Desa VP324E — COMBUSTION AIR KIT MODEL AK4 (OPTIONAL) diagram (page 14)
Fig. 40

These B-vent fireplaces are approved for use with optional bi-fold glass doors (see Accessories, page 21). The glass doors may be ordered and installed anytime after the fireplace installation is complete.

Installing Glass Doors 1. With the handle at the bottom, completely fold the panel on its hinges. 2. With the handle facing the center of the firebox opening, insert the lower pivot pin on the glass door panel into the hole in pivot plate on the bottom edge of the fireplace opening (see Figure 30). 3. Keeping the folded door tilted, slide the upper two pins into the guide track found under the upper facial edge of the fire- box opening. 4. Tilt the door assembly fully vertical until the outer pivot pin snaps into the mounting hole in the upper spring clip (see Figure 30). 5. Once the top and bottom pins are secured, unfold the door into the closed position. 6. Repeat the process for the opposite door assembly. 7. To adjust the doors, slide them partially open. Using a screw- driver, loosen the hold-down screws in the spring clip (see Fig- ure 31, page 15) and pivot plate.

Figure 28 - Air Kit Handle Location

APPLIANCE ENCLOSURE

Before finishing the enclosure around the appliance, inspect all joints around the outer surround. Any gaps between the nailing flanges and the framing should be sealed with noncombustible insulation or caulking.

Slide Top Pin Into Door Track

If the appliance is mounted on a raised platform, it must be a continuous surface and not on blocks without a solid surface. This will prevent the entry of cold air by means of conduction through the total bottom of the appliance. (see Figure 29).

Desa VP324E — APPLIANCE ENCLOSURE diagram (page 14)
Fig. 41

Insert Pin Into Spring Clip

Insert Bottom Pivot Pin Into Pivot Plate and Swing Door Into Vertical Position

Caulk Here Pack Insulation

Figure 29 - Sealing Between Appliance and Framing

Figure 30 - Installing Optional Glass Door

For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 4 more labels / short text on this page
Spring Clip · Side Framing · Side Framing · Pivot Plate
Page 15 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 15 · click to enlarge
Page 15
Desa VP324E — OPERATING FIREPLACE diagram (page 15)
Fig. 42

INSTALLATION Continued

OPERATING FIREPLACE

Desa VP324E — INSTALLATION Continued diagram (page 15)
Fig. 43 · INSTALLATION Continued
8. Close both doors until evenly joined at the middle and note the gap at the outer edges of the face. 9. Reopen one door at a time and retighten the upper and lower hold-down screws. 10. Repeat the process until both doors are evenly joined, spaced and working freely.
  • A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Removing Glass Doors for Replacement or Cleaning 1. Partially open the door and press up on the upper spring clip with a screw driver until the outer top pivot pin is free of the clip. 2. Fully fold the frame assembly and slide the upper edge to- wards the center of the firebox opening until the guide pins are free of the frame rail (see Figure 32).

Spring Clip Hold-Down Screw

Desa VP324E — INSTALLATION Continued diagram (page 15)
Fig. 44 · INSTALLATION Continued

Figure 31 - Adjusting Glass Doors

1. STOP! Read the safety information, above. 2. Turn off all electric power to the appliance. 3. Turn wall switch to the OFF position. 4. Fully open glass doors if installed. 5. Remove front refractory brick access panel. 6. Turn equipment shutoff valve clockwise Clockwise to the OFF position (see Figure 33, page 16). Do not force. 7. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, above. If you don’t smell gas, go to the next step. 8. Turn equipment shutoff valve counterclockwise C-clockwise to the ON position. Do not force. 9. Replace front refractory brick access panel.

Desa VP324E — INSTALLATION Continued diagram (page 15)
Fig. 45 · INSTALLATION Continued

Depress Spring Clip to Release Pivot Pin

Fold Bi-Fold Door After Releasing Spring Clip and Slide Door Out of Upper Track

Remove Bottom Pin From Pivot Plate While Sliding Door Out of the Upper Track

Figure 32 - Removing Glass Doors

For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 4 more labels / short text on this page
Side Front Face · Partially Opened Door · Spring Clip · Pivot Plate
Page 16 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 16 · click to enlarge
Page 16
Desa VP324E — INSPECTING BURNERS diagram (page 16)
Fig. 46

To Turn Off Gas To Appliance Optional Remote Operation INSPECTING BURNERS

OPERATING FIREPLACE Continued

  • 10. Fully close glass doors if installed. 11. Turn on all electric power to the appliance. 12. Turn the wall switch to the ON position. 13. Visually locate the pilot. The ignitor should begin to spark and the main burner should ignite once flame appears at pilot.
  • If lighting the appliance for the first time each season, it may take several attempts before the supply gas can reach the pilot and main burners.
  • If the appliance will not stay lit after several attempts, follow the instructions To Turn Off Gas To Appliance , below, and call your service technician or gas supplier.

OPTIONAL REMOTE OPERATION

Note: The WRC receiver and hand-held remote control kit must be purchased separately (see Accessories, page 21). Follow installation instructions on page 10. 1. Turn equipment shutoff valve to ON position. You can now turn the burner on and off with the hand-held remote control unit. IMPORTANT: Be sure to press the ON/OFF buttons on the hand-held remote control unit for up to 3 seconds to assure proper operation. 2. Press the ON/OFF button to turn the burner on and off.

INSPECTING BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT ASSEMBLY

The pilot assembly is factory preset for the proper flame. Alterations may have occurred during shipping and handling. The pilot is located on the back right hand side of the burner.

Figure 33 - Turning Equipment Shutoff Valve to the OFF Position

TO TURN OFF GAS

The flame must envelope 1/4" of top of the ignitor/sensor and grounding stem.

TO APPLIANCE 1. Turn off the wall switch. 2. Turn off all electric power to the appliance if service is to be performed. 3. Fully open glass doors if installed. 4. Remove front hearth brick and control access panel. 5. Turn equipment shutoff valve clockwise Clockwise to OFF. Do not force. 6. Replace front refractory brick access panel. 7. Fully close glass doors if installed.

  • If your pilot assembly does not meet these requirements:
  • Turn the adjustment screw marked PILOT clockwise to decrease or counterclockwise to increase the flame to proper size (see Figure 35). Do not remove the adjustment screw.
  • see Troubleshooting , pages 19 and 20

Sensing Rod Pilot Burner

Figure 35 - Correct Pilot Flame Pattern

Figure 34 - Pilot

For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 6 more labels / short text on this page
Equipment Shutoff Valve · Adjustment Screw · Sensing Rod · Pilot Burner · Ignitor/Sensor · Ignitor
Page 17 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 17 · click to enlarge
Page 17
Desa VP324E — cleaning and maintenance diagram (page 17)
Fig. 47 · cleaning and maintenance

INSPECTING BURNERS Continued

CLEANING AND MAINTENANCE

BURNER FLAME PATTERN

Desa VP324E — BURNER FLAME PATTERN diagram (page 17)
Fig. 48

WARNING: Installation and repair should be done by a qualified service person. The appliance should be inspected before each use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bed- ding material, pet hair, etc. It is imperative that the control compartments, burners, and circulating air sys- tem be kept clean.

Burner flames will be steady; not lifting or floating. Flames should go up through the middle of logset. Flames should not "spill" to the edges of the pan or sides of the logset.

  • Figure 36 shows a typical flame pattern. If burner flame pattern differs from that described:
  • turn appliance off (see To Turn Off Gas to Appliance , page 16)
  • see Troubleshooting , pages 19 and 20
Desa VP324E — BURNER FLAME PATTERN diagram (page 17)
Fig. 49
  • PILOT AND BURNER
  • Remove logs and ember material before cleaning burner and replace when cleaning is complete.
  • Burner and controls should be cleaned with compressed air to remove dust, dirt, or lint.
  • Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt, or lint.

P324E and VP324E Models

Desa VP324E — BURNER FLAME PATTERN diagram (page 17)
Fig. 50
  • LOGS
  • If you remove logs for cleaning, refer to log placement information on pages 12 and 13 to properly replace logs.
  • Use a vacuum cleaner to remove any carbon buildup on logs.
  • Replace log(s) if broken. See Replacement Parts, page 18.
  • Replace ember material periodically as needed. See Replacement Parts, page 18.

P325E(B) and VP325E(B) Models

Figure 36 - Typical Flame Pattern

For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 18 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 18 · click to enlarge
Page 18
Desa VP324E — SERVICE HINTS diagram (page 18)
Fig. 51

SERVICE HINTS

REPLACEMENT PARTS

  • When Gas Pressure Is Too Low
  • pilot will not stay lit
  • burner will have delayed ignition
  • fireplace will not produce specified heat
  • propane/LP gas supply may be low if using propane/LP gas

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA International’s Customer Service Department at 1-866-672-6040 for referral information.

You may feel your gas pressure is too low. If so, contact your local gas supplier.

  • When calling DESA International, have ready
  • your name
  • your address
  • model and serial numbers of your fireplace
  • how fireplace was malfunctioning
  • type of gas used (propane/LP or natural gas)
  • purchase date

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Customer Ser- vice Department at 1-866-672-6040.

You can also visit DESA International’s technical services web site at www.desatech.com

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA International at 1-866-672-6040 for referral information.

  • When calling DESA International, have ready
  • model number of your fireplace
  • the replacement part number

WIRING DIAGRAM

Desa VP324E — WIRING DIAGRAM diagram (page 18)
Fig. 52

For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 19 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 19 · click to enlarge
Page 19
Desa VP324E — TROUBLESHOOTING diagram (page 19)
Fig. 53

TROUBLESHOOTING The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control valve filter

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Ignitor will not spark or pilot will not light

1. No gas supply, or shutoff valve is OFF

1. Check to see if you have gas supply and that equipment shutoff valve is opened 2. Repeat lighting procedure several times to purge all air out of lines. If after re- peated attempts appliance does not light, call for qualified service and repair. 3. Remove debris and dirt, inspect and clean any other possible obstructions 4. Contact your gas supplier to check pressure 5. Have a qualified technician replace pi- lot line 6. Replace control valve (Refer to Replace- ment Parts, page 18) 7. Check that main power is on and that all wire connections are made correctly to the ignition model (see Wiring Diagram, page 18). Check for 24 VAC at the sec- ondary side of the transformer. If 24 VAC is present, and the module does not oporate, have the module replaced oth- erwise have the transformer replaced. 8. Open vent damper until fully locked in OPEN position

2. Air in gas line
3. Construction debris clogging pilot orifice
4. Low gas pressure
5. Kinked pilot line
6. Control valve knob is not opening
7. No power to unit or the ignition module or power transformer is bad
8. Vent damper not fully open

Pilot will not stay lit

1. Loose wiring on ignitor wire to ignition module and/or poor ground to ignition module
1. Check wiring connection. Refer to wiring diagram (see Wiring Diagram , page 18) and/or check ground wire to ignition module 2. Clean and adjust pilot burner and check gas supply and inlet pressure to unit
2. Pilot flame too low to sense

No gas to burner, although wall switch and valve are set to the ON position

1. Wall switch wires defective or too long 2. Thermopile not generating sufficient voltage
1. Check electrical connections 2. Recheck problems 1 and 2
1. Pilot flame may be too low, causing safety pilot to “drop out” 2. Improper venting or excessive blockage
1. Clean and adjust pilot flame for maximum flame impingement on thermopile 2. Have the vent system inspected, including the termination cap. Remove any restriction or obstruction

For more information, visit www.desatech.com For more information, visit www.desatech.com

Frequent pilot outage

Page 20 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 20 · click to enlarge
Page 20
Desa VP324E — TROUBLESHOOTING diagram (page 20)
Fig. 54

TROUBLESHOOTING Continued

Desa VP324E — TROUBLESHOOTING Continued diagram (page 20)
Fig. 55 · TROUBLESHOOTING Continued
  • WARNING: If you smell gas
  • Shut off gas supply.
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Fireplace produces a clicking/ticking noise just after burner is lit or shut off

1. Metal expanding while heating or contracting while cooling
1. This is common with most fireplaces. If noise is excessive, contact qualified service person

Fireplace produces unwanted odors

1. Fireplace burning vapors from paint, hair spray, glues, etc. (See IMPORTANT statement above) 2. For propane/LP gas, low fuel supply 3. Gas leak. See Warning statement at top of page
1. Ventilate room. Stop using odor causing products while fireplace is running
2. Contact local propane/LP supplier 3. Locate and correct all leaks (see Gas Line Hook-Up , pages 10 and 11)

Gas odor even when control knob is in OFF position

1. Gas leak. See Warning statement at top of page 2. Control valve defective
1. Locate and correct all leaks (see Gas Line Hook-Up , pages 10 and 11) 2. Replace control valve

Gas odor during combustion

1. Foreign matter between control valve and burner 2. Gas leak. See Warning statement at top of page
1. Take apart gas tubing and remove foreign matter 2. Locate and correct all leaks (see Gas Line Hook-Up , pages 10 and 11)

Dark residue on logs or inside of fireplace

1. Improper log placement
1. Properly locate logs (see Log Placement on pages 12 and 13) 2. Clean out air holes at burner inlets. Periodically repeat as needed 3. Remove blockage or replace burner 4. Have the vent system inspected, including the termination cap. Remove any restrictions or obstruction 5. Clear excess embers until a minimum gap of 1/2" remains under the grate
2. Air holes at burner inlet blocked
3. Burner flame holes blocked 4. Improper venting or excessive blockage
5. Excessive amounts of embers and pan material

For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 21 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 21 · click to enlarge
Page 21
Desa VP324E — Accessories diagram (page 21)
Fig. 56 · Accessories

ACCESSORIES

Purchase these firebox accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-866-672-6040 for information. You can also write to the address listed on the back page of this manual.

LOUVER TRIM (Rolled Louvers Only) LT32B - 32" Louver Trim Kit - Brushed Brass LT32P - 32" Louver Trim Kit - Platinum LT32PB - 32" Louver Trim Kit for VP325E(B) - Polished Brass

AIR KIT - AK4 Optional kit helps offset the negative pressure often existing in today's tightly constructed homes.

FACE/LOUVER PANEL KITS

SP32 - Smooth Faced Panel Kit- Black SL32 - Stamped Louver Panel Kit- Black RL32 - Rolled Louver Kit- Black FP32 - Filigree Panel Kit- Black FP32B - Filigree Panel Kit- Brushed Brass FP32P - Filigree Panel Kit- Platinum FP32PB - Filigree Panel Kit- Polished Brass

REMOTE CONTROL KITS WRC - Standard On/Off Electronic Remote Control Kit

PROPANE CONVERSION KITS PCBE-324 - Propane Conversion Kit for 4" B-Vent Electronic Fireplace PCBE-325 - Propane Conversion Kit for 5" B-Vent Electronic Fireplace

EXTRUDED ALUMINUM BI-FOLD GLASS DOORS BD32 - 32" Black Finish BD32B - 32" Brushed Brass Finish BD32P - 32" Platinum Finish

BRICK LINER

BL32 - 32" Refractory Standard Brick Liner Kit

BLOWER KIT BK - Squirrel Cage Blower With Speed Control

PERIMETER TRIM PT32 - 32" Perimeter Trim - Black PT32B - 32" Perimeter Trim - Brushed Brass PT32PB - 32" Perimeter Trim - Polished Brass PT32P - 32" Perimeter Trim - Platinum

For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 22 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 22 · click to enlarge
Page 22
Desa VP324E — ILLUSTRATED PARTS BREAKDOWN and parts list diagram (page 22)
Fig. 57 · ILLUSTRATED PARTS BREAKDOWN and parts list

ILLUSTRATED PARTS BREAKDOWN

Desa VP324E — ILLUSTRATED PARTS BREAKDOWN diagram (page 22)
Fig. 58

For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 23 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 23 · click to enlarge
Page 23
Desa VP324E — ILLUSTRATED PARTS BREAKDOWN and parts list diagram (page 23)
Fig. 59 · ILLUSTRATED PARTS BREAKDOWN and parts list

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 18 of this manual.

P324E AND VP324E MODELS

KEY PART NO. NUMBER DESCRIPTION QTY. 1 108406-01 Insulation Pan 1 2 108403-02 Fireplace Top Assembly 1 3 108405-01 Fireplace Surround 1 4 108425-01 Air Rod Retainer 1 5 108423-01 Panel Closure 2 6 108409-01 Firebox Bottom 1 7 108410-01 Firebox Surround 1 8 108411-01 Air Separator 1 9 11186 Screw, #8-32 x 1" PPH Zinc. 2 10 11109 Screw, #8-32 x 1/2" PPH Zinc. 2 11 11201 Nut, #8-32 Hex Zinc. 4 12 108428-03 Bottom Front Refractory, Std. Brick 1 13 108426-03 Bottom Rear Refractory, Std. Brick 1 14 106683-01 Firebox Support Leg 2 15 24353 Box Assembly 1 16 108701-01 Screen Rod 2 17 108407-02 Firebox Top Assembly 1 18 11165 Screw, #10x5/8 Mod. Tr. Blk. Ox 2 19 106703-02 Damper Door Assembly 1 20 108401-01 Firebox Face 1 21 108412-01 Smoke Deflector 1 22 109099-01 Fireplace Top Insulation 1 23 109797-01 Grate Assembly 1 24 109107-02 Burner Assembly 1 24-1 107742-03 Burner Pan 1 24-2 109794-01 Burner Tube 1 24-3 107748-01 Burner Bracket 1 24-4 107985-01 Pilot Shield 1 24-5 109793-01 Divider Pan 1 24-6 11209 Nut, #10-24 1 24-7 11147 Screw, #10-24x1/2 1 24-8 901066-01 Brass Air Mixer (Natural Gas) 1 901066-02 Brass Air Mixer (Propane/LP) 1 24-9 901064-12 Injector (Natural Gas) 1 901065-11 Injector (Propane/LP) 1 24-10 108866-01 Pilot (Natural Gas) 1

KEY PART NO. NUMBER DESCRIPTION QTY.

24-11 108867-01 Pilot Orifice (Propane/LP) 1 24-12 11102 Screw, #8-32x3/8 2 25 14569 Electronic Gas Valve (Natural Gas) 1 14570 Electronic Gas Valve (Propane/LP Gas) 1 26 107741-02 Valve Bracket 1 27 14129 Transformer 1 28 108368-01 3/8" Flex Line 1 29 11107 Screw, #10-32 x 1/4 PPH 4 30 108005-05 Wire Harness 1 31 11418 Push-On Nut 2 32 108440-01 Screen 2 33 14123 Strain Relief 1 34 14574 Limit Switch 1 35 22912 Draft Diverter 1 36 106827-01 4" Gasket 1 37 20042 Air Kit Cover 1 38 20088 Door Stop 1 39 20089 Pivot Clip 2 40 20090 Spring Clip 2 41 21171 Gas Knockout Cover 4 42 108652-01 Gas Conduit Assy, Left 1 43 108654-01 Gas Conduit Assy, Right 1 44 20280 Top Spacer 4 45 108415-01 Starter Pipe Collar 1 46 108416-01 4" Collar 1 47 14301 Ignition Module SP745 1 48 14253 Flexible Supply Line w/ Shutoff Valve 1 49 108863-01 24" Supply Connect Plug 1 50 108864-01 Strain Relief 1/2" Bushing 1 51 109098-01 Wire Assembly Elec. Harness 1 52 108769-03 Extension Deflector 2 PARTS AVAILABLE NOT SHOWN 901155-01 Vermiculite Bag 1 901156-01 Pan Material 1 901157-01 Lava Rock 1 22180 Wall Switch Kit 1

For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 24 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 24 · click to enlarge
Page 24
Desa VP324E — ILLUSTRATED PARTS BREAKDOWN and parts list diagram (page 24)
Fig. 60 · ILLUSTRATED PARTS BREAKDOWN and parts list

ILLUSTRATED PARTS BREAKDOWN

Desa VP324E — ILLUSTRATED PARTS BREAKDOWN diagram (page 24)
Fig. 61

For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 25 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 25 · click to enlarge
Page 25
Desa VP324E — ILLUSTRATED PARTS BREAKDOWN and parts list diagram (page 25)
Fig. 62 · ILLUSTRATED PARTS BREAKDOWN and parts list

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 18 of this manual.

P325E(B) AND VP325E(B) MODELS

KEY PART NO. NUMBER DESCRIPTION QTY. 1 108406-01 Insulation Pan 1 2 108403-01 Fireplace Top Assembly 1 3 108405-01 Fireplace Surround 1 4 108425-01 Air Rod Retainer 1 5 108423-01 Panel Closure 2 6 108409-01 Firebox Bottom 1 7 108410-01 Firebox Surround 1 8 108411-01 Air Separator 1 9 108434-01 Left Refractory, Std. Brick (B Models) 1 10 108432-01 Right Refractory, Std. Brick (B Models) 1 11 108430-01 Rear Refractory, Std. Brick (B Models) 1 12 108428-01 Bottom Front Refractory, Std. Brick 1 13 108426-01 Bottom Rear Refractory, Std. Brick 1 14 106683-01 Firebox Support Leg 2 15 24353 Box Assembly 1 16 108701-01 Screen Rod 2 17 108407-01 Firebox Top Assembly 1 18 11165 Screw, #10x5/8 Mod. Tr. Blk. Ox 2 19 106703-02 Damper Door Assembly 1 20 108401-01 Firebox Face 1 21 108412-01 Smoke Deflector 1 22 109099-01 Fireplace Top Insulation 1 23 109040-01 Grate Assembly 1 24 108712-06 Burner Assembly 1 24-1 107742-03 Burner Pan 1 24-2 109037-01 Burner Tube 1 24-3 107748-01 Burner Bracket 1 24-4 107985-01 Pilot Shield 1 24-5 901681-01 Burner Clamp 1 24-6 11209 Nut, #10-24 1 24-7 11147 Screw, #10-24x1/2 1 24-8 901066-01 Brass Air Mixer (Natural Gas) 1 901066-02 Brass Air Mixer (Propane/LP) 1 24-9 901064-11 Injector (Natural Gas) 1 901065-09 Injector (Propane/LP) 1 24-10 108866-01 Pilot (Natural Gas) 1 24-11 108867-01 Pilot Orifice (Propane/LP) 1 24-12 11102 Screw, #8-32x3/8 2

KEY PART NO. NUMBER DESCRIPTION QTY.

25 14569 Electronic Gas Valve (Natural Gas) 1 14570 Electronic Gas Valve (Propane/LP Gas) 1 26 107741-02 Valve Bracket 1 27 14129 Transformer 1 28 108368-01 3/8" Flex Line 1 29 11107 Screw, #10-32 x 1/4 PPH 4 30 108005-05 Wire Harness 1 31 11418 Push-On Nut 2 32 108440-01 Screen 2 33 14123 Strain Relief 1 34 14574 Limit Switch 1 35 22912 Draft Diverter 1 36 22084 Brick Liner Retainer 2 37 20042 Air Kit Cover 1 38 20088 Door Stop 1 39 20089 Pivot Clip 2 40 20090 Spring Clip 2 41 21171 Gas Knockout Cover 4 42 108652-01 Gas Conduit Assy, Left 1 43 108654-01 Gas Conduit Assy, Right 1 44 20280 Top Spacer 4 45 108415-01 Starter Pipe Collar 1 46 108417-01 5" Collar 1 47 14301 Ignition Module SP745 1 48 14253 Flexible Supply Line w/ Shutoff Valve 1 49 108863-01 24" Supply Connect Plug 1 50 108864-01 Strain Relief 1/2" Bushing 1 51 109098-01 Wire Assembly Elec. Harness 1 52 11186 Screw, #8-32 x 1" PPH Zinc. 2 53 11109 Screw, #8-32 x 1/2" PPH Zinc. 2 54 11201 Nut, #8-32 Hex Zinc. 2 55 108769-03 Extension Deflector 2 PARTS AVAILABLE NOT SHOWN 901155-01 Vermiculite Bag 1 901156-01 Pan Material 1 901157-01 Lava Rock 1 22180 Wall Switch Kit 1

For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 26 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 26 · click to enlarge
Page 26
Desa VP324E — ILLUSTRATED PARTS BREAKDOWN and parts list diagram (page 26)
Fig. 63 · ILLUSTRATED PARTS BREAKDOWN and parts list

ILLUSTRATED PARTS BREAKDOWN

LOG ASSEMBLY

Desa VP324E — LOG ASSEMBLY diagram (page 26)
Fig. 64
Desa VP324E — LOG ASSEMBLY diagram (page 26)
Fig. 65

P325E(B) and VP325E(B) Models

P324E and VP324E Models

Desa VP324E — LOG ASSEMBLY diagram (page 26)
Fig. 66
Desa VP324E — LOG ASSEMBLY diagram (page 26)
Fig. 67

- 109109-01 Log Set 1 105958-05 Front Log 1 2 105960-05 Rear Log 1 3 901100-02 Top Right Log 1 4 901102-02 Top Left Log 1

- 109100-02 Log Set 1 109421-01 Rear Log 1 2 109420-01 Front Right Log 1 3 108723-01 Front Left Log 1 4 108722-01 Top Y-Log 1 5 108720-01 Top Log 1

For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 27 of the Desa VP324E user manual — _______________________________________________________________________________________________
Page 27 · click to enlarge
Page 27
Desa VP324E — ILLUSTRATED PARTS BREAKDOWN and parts list diagram (page 27)
Fig. 68 · ILLUSTRATED PARTS BREAKDOWN and parts list

NOTES

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

_______________________________________________________________________________________________

For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 28 of the Desa VP324E user manual — For more information, visit www.desatech.com For more information, visit www.desatech.com
Page 28 · click to enlarge
Page 28
Desa VP324E — WARRANTY INFORMATION Back Page diagram (page 28)
Fig. 69 · WARRANTY INFORMATION Back Page
Desa VP324E — WARRANTY INFORMATION Back Page diagram (page 28)
Fig. 70 · WARRANTY INFORMATION Back Page

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY B-VENT FIREPLACE

DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR (4) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNA- TIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

TM

2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com

108794-01 Rev. B 01/02 NOT A UPC

For more information, visit www.desatech.com For more information, visit www.desatech.com

108794 01

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
BD3232" Black Finish p.21
BD32B32" Brushed Brass Finish p.21
BD32P32" Platinum Finish p.21
BL3232" Refractory Standard Brick Liner Kit p.21
PT3232" Perimeter Trim - Black p.21
PT32B32" Perimeter Trim - Brushed Brass p.21
PT32P32" Perimeter Trim - Platinum p.21
LT32B32" Louver Trim Kit - Brushed Brass p.21
LT32P32" Louver Trim Kit - Platinum p.21
SP32Smooth Faced Panel Kit- Black p.21
SL32Stamped Louver Panel Kit- Black p.21
RL32Rolled Louver Kit- Black p.21
FP32Filigree Panel Kit- Black p.21
FP32BFiligree Panel Kit- Brushed Brass p.21
FP32PFiligree Panel Kit- Platinum p.21

Ask about the Desa VP324E

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Desa VP324E

Be the first to ask — other owners or our team will answer.

Original document

Desa VP324E manual PDF

28 pages·4.1 MB·Outdoor Fireplace·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…