MODELS P324E, VP324E, P325E(B) AND VP325E(B)
NATURAL GAS
SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appli- ance, it also contains information that will enable you to obtain replacement parts or optional accessory items when needed. Keep it with your other important papers.
FOR YOUR SAFETY — Do not store or use gasoline or any other flam-
mable vapors or liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS :
CHECK LOCAL CODES PRIOR TO
INSTALLATION
qualified installer, service agency, or the gas supplier.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
Save this manual for future reference. Save this manual for future reference.



UNPACKING
8. Turn fireplace off and let cool before servicing or repairing. Only a qualified service person should install, service, or re- pair this fireplace. Have fireplace inspected annually by a quali- fied service person. 9. You must keep control compartments, burners, and circulating air passages clean. More frequent cleaning may be needed due to excessive lint and dust from carpeting, bedding material, etc. Turn off the gas valve and pilot light before cleaning fireplace. 10. Have venting system inspected annually by a qualified service person. If needed, have venting system cleaned or repaired. See Cleaning and Maintenance, page 17. 11. Keep the area around your fireplace clear of combustible ma- terials, gasoline, and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around fireplace. 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fireplace nameplate. 14. This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Ca- nadian Electrical Code, CSA C22.1. 15. Do not install fireplace directly on carpeting, vinyl tile, or any com- bustible material other than wood. The fireplace must set on a metal or wood panel extending the full width and depth of the fireplace. 16. Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service person to arrange for replacement of the unit. 17. Do not operate fireplace if any log is broken. 18. Do not use a blower insert, heat exchanger insert, or other ac- cessory not approved for use with this fireplace.
Check all items for any shipping damage. If damaged, promptly inform dealer or distributor where you bought the product.
Safely retain these items for later installation.


These fireplace models are vented gas fireplaces that use an elec- tronic gas control valve and electronic ignition system. P325E/ VP325E models have a 5" B-vent and P324E/VP324E models have a 4" B-vent. A properly sized B-Type venting system and a listed type vent cap are not supplied but are required for proper operation. See venting instructions on pages 8 and 9.
The installation must conform with local codes or, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1 or with the current CAN/CSA B149 Installation Codes.
This appliance complies with ANSI Z21.50-2000 and CSA 2.22- 2000 as Vented Gas Fireplaces and is listed and tested by the Canadian Standards Association to the above test standards.
These models are factory equipped for use with natural gas and must be converted when intended for use with propane/LP gas. Conversion kits PCBE-324 and PCBE-325 may be purchased for simple conver- sion to propane/LP gas. See Accessories, page 21.
Before beginning the installation of your appliance, read these instructions through completely.
This DESA appliance and its approved components are safe when installed according to this installation manual and are operated as recommended by DESA. Unless you use DESA approved components tested for this appliance, YOU MAY CAUSE A FIRE HAZARD!
The appliance and it’s individual shutoff valve must be discon- nected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
The DESA warranty will be voided by, and DESA disclaims any responsibility for the following actions : A) Modification of the appliance or any of the components. B) Use of any component part not approved by DESA in combi- nation with this appliance. C) Installation and/or operation in a manner other than instructed in this manual. D) The burning of anything other than the type of gas approved
The appliance must be isolated from the gas supply piping system by closing its individual equipment shutoff valve during any pres- sure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
For the purpose of input adjustment two pressure taps (for IN and OUT pressures) are provided on the gas control valve for test gauge connections to the appliance.
for use in this gas appliance.


21 1/2"

* 13 3/4" 14 1/2"
2 1/2" 8 1/4"
35 3/8" 29 1/2"
7 5/8" 10 5/8"
Figure 1 - Appliance Dimensions
To determine the safest and most efficient location for your appli- ance, you must take into consideration the following guidelines: 1. The location must allow for proper clearances (see Clear- ances, page 6). 2. Consider a location where heat output would not be affected by drafts, air conditioning ducts, windows, or doors. 3. A location that avoids the cutting of joists or roof rafters will make installation easier. Figure 2 shows a plan view of a few common locations.
Internal wall installations provide a discreet option for room separation and can also be ideal as an addition to an existing wall.

Flush installations are recommended where living space is limited or at a premium, and since the space required to enclose the appliance would be located beyond an outside wall, this would also reduce the cutting of joists, roof rafters, and such. Check local codes for any restrictions.
Projected installations can extend any distance into the room. A projection may be ideal for a new addition on an existing, finished wall.
Figure 2 - Possible Locations for Installing Appliance
Corner installations make use of space that may not normally be used and provides a wider and more efficient range for radiant heat transference.


MANTEL CLEARANCES AND WALL DETAILS
A combustible mantle shelf maybe installed a maximum 12" (229mm) from the wall. Figures 5 and 6 show the minimum allowable distances from various combustible mantle components in relation to the fireplace opening.

2 x 4 Stud

Figure 5 - Mantel Clearances - Side View (Cross Section)
Figure 3 - Minimum Clearances (Top View)
1" (25mm) Min. Clearance to "B" Vent’s Outer Pipe

1 1/2" (38mm) Max. 3" (76mm) Max.
Required Air Spaces are Indicated with an "*". Do Not Pack with Insulation or Any Other Material DO NOT BLOCK
Figure 6 - Side Clearances - Top View (Cross Section)
Left Side Surround · Front Face · Drywall


FRAMING 1. Frame appliance enclosure as illustrated in Figures 7 and 8. Note: If a wall covering is used to line the enclosure, then all measurements must be from the surface of the covering. 2. Place the appliance into the framing and secure it. Note: If appliance is to be raised above floor level, a platform must be built to support the appliance. 3. Install the supply line to the appliance using a 1/2" NPT black iron gas line terminating 2 5/16" above the bottom of the appli- ance. The gas line may be installed from either side or from the rear of the appliance (see Figure 16, page 11). 4. Feed flexible gas line through one of three gas line conduit sleeve and repack insulation to cover any openings. Prepare the incoming gas line with teflon tape or pipe joint compound and hook-up incoming gas line to the flexible gas line. Note: If 1/2" NPT black iron pipe does not mate with fitting at the end of flexible gas line, remove fitting and replace with a 37 degree flare 3/4"-12, 1/2" NPT (female) fitting.
These Dimensions Allow for a 3/4" Clearance at Sides and Back of Fireplace. However, 0" Clearance is Permitted

3/4" Clearance Not Required at Nailing Flanges
Figure 8 - Corner Installation Guidelines

Figure 7 - Rough Opening for Installing in Wall


A B-type venting system must be connected to the appliance for venting to the outside of the building.
Example 1: Shows the minimum allowable system height and lateral offset for a 60° degree or greater inclination. Code specifies that offsets at 60° degrees or greater are considered horizontal and must follow the 75% percent rule for lateral to total vertical system height. Codes also allows only one offset in the total system when at 60° degrees or greater. The total vertical height in this example represents the minimum height of 8 feet and therefore the allowable lateral is 6 feet when the 75% percent rule applies. If the lateral length must exceed 75% then the system must be sized in accor- dance with the Category I venting tables.
The following section is provided as a guide to a standard B-type vent installation.
Standing codes requirements concerning B-type vent installations may vary within your state, province or local codes jurisdiction. Therefore, it is recommended that you check with your local building codes for specific requirements or in absence of local codes, follow Section 7.0 of the current National Fuel Gas Code NFPA No. 54/ANSI Z223.1 and in Canada with CAN/CSA B149 for Category I systems using double wall B-1 vent pipe.
Example 2: Shows a multiple offset each at 45° degrees of inclination. Multiple offsets are permitted if they do not exceed 60° degrees of inclination. The total lengths of the two offsets are not required to meet the 75% percent allowable rule.
This gas appliance must be vented to the outdoors only and may not be terminated into an attic space or into a chimney flue servicing a solid-fuel burning appliance.
Example 3: Shows a single offset at 45° degrees of inclination and therefore the lateral length at 10 feet of offset does not have to meet the 75% percent rule.
This appliance may be vented through a manufactured chimney system or a masonry chimney using a B-vent adapter or a chimney liner system if all are listed, inspected and approved by local codes and/or building authorities.
In each case the offsets must be supported and firestops must be positioned wherever the vent must pass through a sub-floor, ceiling joist or an attic overhang. The vent pipe must terminate vertically into a listed type vent cap and extend a sufficient height through an approved roof flashing, roof jack or a roof thimble. At all points the listed clearances must be maintained.
The examples shown in Figure 9 are typical of most B-vent installations and codes practices.

Support Each Lateral At Least Every Six (6) Feet
Figure 9 - Typical B-Vent Configuration
Listed Vent Cap


Vent terminations must be located in accordance with height and proximity rules of NFPA No. 54 or CAN/CSA B149. These rules apply to vents at 12 in. diameter or less and require a minimum height in accordance with the roof pitch and a minimum of 8 ft. distance from a vertical wall or obstruction (see Figure 10).

If venting horizontally through a side wall becomes necessary, a listed thimble approved for use with B-type vent must be used. Check with your local codes before venting through a side wall.
Some codes areas allow the use of existing B-type vent systems if the system is at or above the recommended diameter of the flue.
The flue connection must be made using listed B-type connectors and the existing system must be code inspected for damage and proper installation.
After completing and checking the electrical, gas and vent connec- tions, follow the lighting instructions and allow the main burner to run for approximately 5 minutes. Hold a lighted match or cigarette near the top edge of the fireplace opening and play it along the entire length of the opening (see Figure 11). Proper venting should tend to draw the flame or smoke into the appliance. Improper venting or escaping of spillage of burned gas, is indicated when the match flickers or goes out. Smoke from a cigarette will also tend to disperse away from the appliance.
It is not recommended that this appliance be common vented with an existing gas burning appliance. However, if it becomes necessary to common vent this appliance, the venting system must be sized and configured in accordance with the common venting guides Appendix G of the current National Fuel Gas Code NFPA No. 54/ ANSI Z223.1 and in Canada with CAN/CSA B149.
If the appliance is found to be improperly venting, shut it off and notify your installer or a qualified service agency to inspect the venting system.


Check this area along the entire top edge of the fireplace opening. Smoke or flame should be drawn into the appliance opening.

Flat to 6/12 1.0 0.30 6/12 to 7/12 1.25 0.38 Over 7/12 to 8/12 1.5 0.46 Over 8/12 to 9/12 2.0 0.61 Over 9/12 to 10/12 2.5 0.76 Over 10/12 to 11/12 3.25 0.99 Over 11/12 to 12/12 4.0 1.22 Over 12/12 to 14/12 5.0 1.52 Over 14/12 to 16/12 6.0 1.83 Over 16/12 to 18/12 7.0 2.13 Over 18/12 to 20/12 7.5 2.27 Over 20/12 to 21/12 8.0 2.44
Figure 10 - B-Vent Terminations
Figure 11 - Checking for Spillage


Wall Switch Installation Optional Remote Control Installation (Model WRC) Gas Line Hook-Up

The installation of a wall switch allows you to activate the gas control valve and turn the fireplace on and off. The wall switch is to be connected to the incoming 120 volt regular household wiring that supplies the electricity to the fireplace. Refer to wiring diagram in this manual on page 18.
Note: If using optional wireless hand-held remote control, the wall switch must be in the ON position to be operational. The remote control then becomes the switching mechanism for fireplace operation. 1. Remove the front refractory access panel by lifting up and an- gling out of the firebox opening (see Figure 12). 2. The WRC model receiver does not require a battery. The re- ceiver can be installed by first plugging the short extension cord into the fireplace receptacle. Then plug the receiver unit into the extension cord. Finally plug the ignition module plug into the receiver unit (see Figure 13). 3. Activate the remote handset battery by removing the insulat- ing tab on the back of the handset (see Figure 14). The battery is included pre-installed. 4. Once the battery is activated the unit is ready to use. 5. Replace front refractory access panel.
Figure 14 - Installing Battery into Back of Handset

A equipment shutoff valve has been included in the appliance’s gas supply system. You may consider installing an extra gas shutoff valve outside the appliance’s enclosure (check with local codes) where it can be accessed more conveniently with a key through a wall as shown in Figure 15.
Typical Exterior Wall Gas Shutoff Installation
Figure 15 - Equipment Shutoff Valve Installation
Figure 12 - Removing Front Refractory Access Panel (P325E/VP325E Model Shown)
Shutoff Valve · Key · Extension


In conformance with local codes, route a 1/2" NPT gas line towards the appliance coming in from any of the 3 directions shown in Figure 16.
Incoming 1/2" Gas Line Permitted by Local Codes
Sediment Trap (Not Supplied)
Side Wall Of Appliance
3" Min. (76mm)
1/2" NPT Incoming Black Iron Gas Line Flexible Gas Line (1 Provided) Can Be Extended Out Either Side

Red Surface Indicates For Propane/LP Use Only

8 3/8" 10 5/8"
Alternate Gas Supply Through Sub-Floor
1/2" NPT Incoming Gas Line Inlet Pressure Tap Outlet Pressure Tap
Figure 16 - Routing Incoming Gas Line
DESA recommends that a black iron gas line be routed from the gas source, through a sediment trap (shown in Figure 17), and into the appliance, Once connected through the appliance, a flexible gas line may be used for ease of installation to gas control valve (see Figure 18).
Figure 18 - Connecting Flexible Gas Line to Millivolt Valve
Before connecting the black iron gas line to the inside of the appliance a sediment trap must be included outside the appliance between the gas line and the gas shutoff valve. It must extend down three (3) inches beyond the center of the pipe. Prepare incoming black iron gas line with teflon tape or pipe joint compound (Check with local building codes).
WARNING: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply a noncor- rosive leak detection fluid to all connections and joints. If bubbles appear, leaks can be detected and corrected. Do not use an open flame for leak testing and do not operate any appliance if a leak is detected.
Complete your gas installation by connecting incoming gas line with flexible gas line. Secure tightly with wrench but DO NOT OVERTIGHTEN.
Figure 17- Sediment Trap


Ember and Pan Material Placement Log Placement for P324E/VP324E Models
EMBER AND PAN MATERIAL PLACEMENT 1. Open the bag(s) of vermiculite and fill the entire burner pan until the burner tube is completely covered (see Figure 19). 2. Smooth the pan material just even with edges of the burner pan. 3. Remove the ember material from the bag and flatten small amounts into quarter size pieces and lay on top of the surface of the pan material (see Figure 20). 4. Place just enough to cover the entire surface and leave about a 1/2 inch gap under the lower grate members to allow air to flow (see Figure 21).
LOG PLACEMENT FOR P324E/VP324E MODELS 1. Place front (log 1) onto front of grate sliding log all the way forward against grate fingers (see Figure 22). 2. Insert pegs on bottom of rear log (log 2) into holes in rear of grate (see Figure 22). 3. Insert pegs on back of log 3 into right hole on log 1 and right hole of log 2 (see Figure 23). 4. Insert pegs on back of log 4 into left hole on log 1 and left hole of log 2 (see Figure 23).
To enhance the look of the hearth you may optionally place the lava rock provided around the front and sides of the burner.


Figure 19 - Fill Entire Burner Pan with Vermiculite (P325E/ VP325E Model Shown)
Ember Material Burner Pan Vermiculite (Pan Material) Grate

Figure 22 - Installing Logs 1 and 2
Figure 20 - Ember Material on Surface of Pan Material (Vermiculite) (P325E/VP325E Model Shown)


Figure 21 - Pan and Ember Material Clearances (P325E/VP325E Model Shown)
Figure 23 - Installing Logs 3 and 4


LOG PLACEMENT FOR P325E(B)/VP325E(B) MODLES 1. Place large back log (log 1) onto grate making sure notches rest over grate (see Figure 24). 2. Place log 2 onto front right side of grate. Gently insert peg on back of log 2 into hole on right front of log 1 (see Figure 24). 3. Insert peg on back of log 3 into hole on left front of log 1 (see Figure 25). Log 3 will rest between first two grate fingers on left of grate assembly (see Figure 25)
To enhance the look of the hearth you may optionally place the lava rock provided around the front and sides of the burner.



Figure 24 - Installing Logs 1 and 2

Figure 26 - Installing Logs 4 and 5

Figure 25 - Installing Log 3
Figure 27 - Logs Installed


Combustion Air Kit Model AK4 (Optional) Appliance Enclosure Installing Optional Glass Door Accessory
INSTALLING OPTIONAL GLASS DOOR ACCESSORY
The outside air kit may be installed on the left side of the fireplace only. The vent can be installed through the outside wall or a ventilated crawl space. The handle to operate the damper door for the outside air inlet will be located inside the left “screen pocket” of the firebox (see Figure 28). Pull the handle to open or push to close.

These B-vent fireplaces are approved for use with optional bi-fold glass doors (see Accessories, page 21). The glass doors may be ordered and installed anytime after the fireplace installation is complete.
Installing Glass Doors 1. With the handle at the bottom, completely fold the panel on its hinges. 2. With the handle facing the center of the firebox opening, insert the lower pivot pin on the glass door panel into the hole in pivot plate on the bottom edge of the fireplace opening (see Figure 30). 3. Keeping the folded door tilted, slide the upper two pins into the guide track found under the upper facial edge of the fire- box opening. 4. Tilt the door assembly fully vertical until the outer pivot pin snaps into the mounting hole in the upper spring clip (see Figure 30). 5. Once the top and bottom pins are secured, unfold the door into the closed position. 6. Repeat the process for the opposite door assembly. 7. To adjust the doors, slide them partially open. Using a screw- driver, loosen the hold-down screws in the spring clip (see Fig- ure 31, page 15) and pivot plate.
Figure 28 - Air Kit Handle Location
Before finishing the enclosure around the appliance, inspect all joints around the outer surround. Any gaps between the nailing flanges and the framing should be sealed with noncombustible insulation or caulking.
Slide Top Pin Into Door Track
If the appliance is mounted on a raised platform, it must be a continuous surface and not on blocks without a solid surface. This will prevent the entry of cold air by means of conduction through the total bottom of the appliance. (see Figure 29).

Insert Pin Into Spring Clip
Insert Bottom Pivot Pin Into Pivot Plate and Swing Door Into Vertical Position
Caulk Here Pack Insulation
Figure 29 - Sealing Between Appliance and Framing
Figure 30 - Installing Optional Glass Door


OPERATING FIREPLACE

Removing Glass Doors for Replacement or Cleaning 1. Partially open the door and press up on the upper spring clip with a screw driver until the outer top pivot pin is free of the clip. 2. Fully fold the frame assembly and slide the upper edge to- wards the center of the firebox opening until the guide pins are free of the frame rail (see Figure 32).
Spring Clip Hold-Down Screw

Figure 31 - Adjusting Glass Doors
1. STOP! Read the safety information, above. 2. Turn off all electric power to the appliance. 3. Turn wall switch to the OFF position. 4. Fully open glass doors if installed. 5. Remove front refractory brick access panel. 6. Turn equipment shutoff valve clockwise Clockwise to the OFF position (see Figure 33, page 16). Do not force. 7. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, above. If you don’t smell gas, go to the next step. 8. Turn equipment shutoff valve counterclockwise C-clockwise to the ON position. Do not force. 9. Replace front refractory brick access panel.

Depress Spring Clip to Release Pivot Pin
Fold Bi-Fold Door After Releasing Spring Clip and Slide Door Out of Upper Track
Remove Bottom Pin From Pivot Plate While Sliding Door Out of the Upper Track
Figure 32 - Removing Glass Doors


To Turn Off Gas To Appliance Optional Remote Operation INSPECTING BURNERS
Note: The WRC receiver and hand-held remote control kit must be purchased separately (see Accessories, page 21). Follow installation instructions on page 10. 1. Turn equipment shutoff valve to ON position. You can now turn the burner on and off with the hand-held remote control unit. IMPORTANT: Be sure to press the ON/OFF buttons on the hand-held remote control unit for up to 3 seconds to assure proper operation. 2. Press the ON/OFF button to turn the burner on and off.
Check pilot flame pattern and burner flame patterns often.
The pilot assembly is factory preset for the proper flame. Alterations may have occurred during shipping and handling. The pilot is located on the back right hand side of the burner.
Figure 33 - Turning Equipment Shutoff Valve to the OFF Position
The flame must envelope 1/4" of top of the ignitor/sensor and grounding stem.
TO APPLIANCE 1. Turn off the wall switch. 2. Turn off all electric power to the appliance if service is to be performed. 3. Fully open glass doors if installed. 4. Remove front hearth brick and control access panel. 5. Turn equipment shutoff valve clockwise Clockwise to OFF. Do not force. 6. Replace front refractory brick access panel. 7. Fully close glass doors if installed.
Sensing Rod Pilot Burner
Figure 35 - Correct Pilot Flame Pattern
Figure 34 - Pilot


CLEANING AND MAINTENANCE

WARNING: Installation and repair should be done by a qualified service person. The appliance should be inspected before each use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bed- ding material, pet hair, etc. It is imperative that the control compartments, burners, and circulating air sys- tem be kept clean.
Burner flames will be steady; not lifting or floating. Flames should go up through the middle of logset. Flames should not "spill" to the edges of the pan or sides of the logset.

P324E and VP324E Models

P325E(B) and VP325E(B) Models
Figure 36 - Typical Flame Pattern


REPLACEMENT PARTS
Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA International’s Customer Service Department at 1-866-672-6040 for referral information.
You may feel your gas pressure is too low. If so, contact your local gas supplier.
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Customer Ser- vice Department at 1-866-672-6040.
You can also visit DESA International’s technical services web site at www.desatech.com
Usually, we will ask you to return the part to the factory.
Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA International at 1-866-672-6040 for referral information.



TROUBLESHOOTING The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control valve filter
POSSIBLE CAUSE
REMEDY
Ignitor will not spark or pilot will not light
1. Check to see if you have gas supply and that equipment shutoff valve is opened 2. Repeat lighting procedure several times to purge all air out of lines. If after re- peated attempts appliance does not light, call for qualified service and repair. 3. Remove debris and dirt, inspect and clean any other possible obstructions 4. Contact your gas supplier to check pressure 5. Have a qualified technician replace pi- lot line 6. Replace control valve (Refer to Replace- ment Parts, page 18) 7. Check that main power is on and that all wire connections are made correctly to the ignition model (see Wiring Diagram, page 18). Check for 24 VAC at the sec- ondary side of the transformer. If 24 VAC is present, and the module does not oporate, have the module replaced oth- erwise have the transformer replaced. 8. Open vent damper until fully locked in OPEN position
Pilot will not stay lit
No gas to burner, although wall switch and valve are set to the ON position
Frequent pilot outage



POSSIBLE CAUSE
REMEDY
Fireplace produces a clicking/ticking noise just after burner is lit or shut off
Fireplace produces unwanted odors
Gas odor even when control knob is in OFF position
Gas odor during combustion
Dark residue on logs or inside of fireplace


Purchase these firebox accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-866-672-6040 for information. You can also write to the address listed on the back page of this manual.
LOUVER TRIM (Rolled Louvers Only) LT32B - 32" Louver Trim Kit - Brushed Brass LT32P - 32" Louver Trim Kit - Platinum LT32PB - 32" Louver Trim Kit for VP325E(B) - Polished Brass
AIR KIT - AK4 Optional kit helps offset the negative pressure often existing in today's tightly constructed homes.
SP32 - Smooth Faced Panel Kit- Black SL32 - Stamped Louver Panel Kit- Black RL32 - Rolled Louver Kit- Black FP32 - Filigree Panel Kit- Black FP32B - Filigree Panel Kit- Brushed Brass FP32P - Filigree Panel Kit- Platinum FP32PB - Filigree Panel Kit- Polished Brass
PROPANE CONVERSION KITS PCBE-324 - Propane Conversion Kit for 4" B-Vent Electronic Fireplace PCBE-325 - Propane Conversion Kit for 5" B-Vent Electronic Fireplace
EXTRUDED ALUMINUM BI-FOLD GLASS DOORS BD32 - 32" Black Finish BD32B - 32" Brushed Brass Finish BD32P - 32" Platinum Finish
BL32 - 32" Refractory Standard Brick Liner Kit
PERIMETER TRIM PT32 - 32" Perimeter Trim - Black PT32B - 32" Perimeter Trim - Brushed Brass PT32PB - 32" Perimeter Trim - Polished Brass PT32P - 32" Perimeter Trim - Platinum





This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 18 of this manual.
KEY PART NO. NUMBER DESCRIPTION QTY. 1 108406-01 Insulation Pan 1 2 108403-02 Fireplace Top Assembly 1 3 108405-01 Fireplace Surround 1 4 108425-01 Air Rod Retainer 1 5 108423-01 Panel Closure 2 6 108409-01 Firebox Bottom 1 7 108410-01 Firebox Surround 1 8 108411-01 Air Separator 1 9 11186 Screw, #8-32 x 1" PPH Zinc. 2 10 11109 Screw, #8-32 x 1/2" PPH Zinc. 2 11 11201 Nut, #8-32 Hex Zinc. 4 12 108428-03 Bottom Front Refractory, Std. Brick 1 13 108426-03 Bottom Rear Refractory, Std. Brick 1 14 106683-01 Firebox Support Leg 2 15 24353 Box Assembly 1 16 108701-01 Screen Rod 2 17 108407-02 Firebox Top Assembly 1 18 11165 Screw, #10x5/8 Mod. Tr. Blk. Ox 2 19 106703-02 Damper Door Assembly 1 20 108401-01 Firebox Face 1 21 108412-01 Smoke Deflector 1 22 109099-01 Fireplace Top Insulation 1 23 109797-01 Grate Assembly 1 24 109107-02 Burner Assembly 1 24-1 107742-03 Burner Pan 1 24-2 109794-01 Burner Tube 1 24-3 107748-01 Burner Bracket 1 24-4 107985-01 Pilot Shield 1 24-5 109793-01 Divider Pan 1 24-6 11209 Nut, #10-24 1 24-7 11147 Screw, #10-24x1/2 1 24-8 901066-01 Brass Air Mixer (Natural Gas) 1 901066-02 Brass Air Mixer (Propane/LP) 1 24-9 901064-12 Injector (Natural Gas) 1 901065-11 Injector (Propane/LP) 1 24-10 108866-01 Pilot (Natural Gas) 1
KEY PART NO. NUMBER DESCRIPTION QTY.
24-11 108867-01 Pilot Orifice (Propane/LP) 1 24-12 11102 Screw, #8-32x3/8 2 25 14569 Electronic Gas Valve (Natural Gas) 1 14570 Electronic Gas Valve (Propane/LP Gas) 1 26 107741-02 Valve Bracket 1 27 14129 Transformer 1 28 108368-01 3/8" Flex Line 1 29 11107 Screw, #10-32 x 1/4 PPH 4 30 108005-05 Wire Harness 1 31 11418 Push-On Nut 2 32 108440-01 Screen 2 33 14123 Strain Relief 1 34 14574 Limit Switch 1 35 22912 Draft Diverter 1 36 106827-01 4" Gasket 1 37 20042 Air Kit Cover 1 38 20088 Door Stop 1 39 20089 Pivot Clip 2 40 20090 Spring Clip 2 41 21171 Gas Knockout Cover 4 42 108652-01 Gas Conduit Assy, Left 1 43 108654-01 Gas Conduit Assy, Right 1 44 20280 Top Spacer 4 45 108415-01 Starter Pipe Collar 1 46 108416-01 4" Collar 1 47 14301 Ignition Module SP745 1 48 14253 Flexible Supply Line w/ Shutoff Valve 1 49 108863-01 24" Supply Connect Plug 1 50 108864-01 Strain Relief 1/2" Bushing 1 51 109098-01 Wire Assembly Elec. Harness 1 52 108769-03 Extension Deflector 2 PARTS AVAILABLE NOT SHOWN 901155-01 Vermiculite Bag 1 901156-01 Pan Material 1 901157-01 Lava Rock 1 22180 Wall Switch Kit 1





This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 18 of this manual.
KEY PART NO. NUMBER DESCRIPTION QTY. 1 108406-01 Insulation Pan 1 2 108403-01 Fireplace Top Assembly 1 3 108405-01 Fireplace Surround 1 4 108425-01 Air Rod Retainer 1 5 108423-01 Panel Closure 2 6 108409-01 Firebox Bottom 1 7 108410-01 Firebox Surround 1 8 108411-01 Air Separator 1 9 108434-01 Left Refractory, Std. Brick (B Models) 1 10 108432-01 Right Refractory, Std. Brick (B Models) 1 11 108430-01 Rear Refractory, Std. Brick (B Models) 1 12 108428-01 Bottom Front Refractory, Std. Brick 1 13 108426-01 Bottom Rear Refractory, Std. Brick 1 14 106683-01 Firebox Support Leg 2 15 24353 Box Assembly 1 16 108701-01 Screen Rod 2 17 108407-01 Firebox Top Assembly 1 18 11165 Screw, #10x5/8 Mod. Tr. Blk. Ox 2 19 106703-02 Damper Door Assembly 1 20 108401-01 Firebox Face 1 21 108412-01 Smoke Deflector 1 22 109099-01 Fireplace Top Insulation 1 23 109040-01 Grate Assembly 1 24 108712-06 Burner Assembly 1 24-1 107742-03 Burner Pan 1 24-2 109037-01 Burner Tube 1 24-3 107748-01 Burner Bracket 1 24-4 107985-01 Pilot Shield 1 24-5 901681-01 Burner Clamp 1 24-6 11209 Nut, #10-24 1 24-7 11147 Screw, #10-24x1/2 1 24-8 901066-01 Brass Air Mixer (Natural Gas) 1 901066-02 Brass Air Mixer (Propane/LP) 1 24-9 901064-11 Injector (Natural Gas) 1 901065-09 Injector (Propane/LP) 1 24-10 108866-01 Pilot (Natural Gas) 1 24-11 108867-01 Pilot Orifice (Propane/LP) 1 24-12 11102 Screw, #8-32x3/8 2
KEY PART NO. NUMBER DESCRIPTION QTY.
25 14569 Electronic Gas Valve (Natural Gas) 1 14570 Electronic Gas Valve (Propane/LP Gas) 1 26 107741-02 Valve Bracket 1 27 14129 Transformer 1 28 108368-01 3/8" Flex Line 1 29 11107 Screw, #10-32 x 1/4 PPH 4 30 108005-05 Wire Harness 1 31 11418 Push-On Nut 2 32 108440-01 Screen 2 33 14123 Strain Relief 1 34 14574 Limit Switch 1 35 22912 Draft Diverter 1 36 22084 Brick Liner Retainer 2 37 20042 Air Kit Cover 1 38 20088 Door Stop 1 39 20089 Pivot Clip 2 40 20090 Spring Clip 2 41 21171 Gas Knockout Cover 4 42 108652-01 Gas Conduit Assy, Left 1 43 108654-01 Gas Conduit Assy, Right 1 44 20280 Top Spacer 4 45 108415-01 Starter Pipe Collar 1 46 108417-01 5" Collar 1 47 14301 Ignition Module SP745 1 48 14253 Flexible Supply Line w/ Shutoff Valve 1 49 108863-01 24" Supply Connect Plug 1 50 108864-01 Strain Relief 1/2" Bushing 1 51 109098-01 Wire Assembly Elec. Harness 1 52 11186 Screw, #8-32 x 1" PPH Zinc. 2 53 11109 Screw, #8-32 x 1/2" PPH Zinc. 2 54 11201 Nut, #8-32 Hex Zinc. 2 55 108769-03 Extension Deflector 2 PARTS AVAILABLE NOT SHOWN 901155-01 Vermiculite Bag 1 901156-01 Pan Material 1 901157-01 Lava Rock 1 22180 Wall Switch Kit 1




P325E(B) and VP325E(B) Models
P324E and VP324E Models


- 109109-01 Log Set 1 105958-05 Front Log 1 2 105960-05 Rear Log 1 3 901100-02 Top Right Log 1 4 901102-02 Top Left Log 1
- 109100-02 Log Set 1 109421-01 Rear Log 1 2 109420-01 Front Right Log 1 3 108723-01 Front Left Log 1 4 108722-01 Top Y-Log 1 5 108720-01 Top Log 1


_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
For more information, visit www.desatech.com For more information, visit www.desatech.com



Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR (4) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNA- TIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com
108794-01 Rev. B 01/02 NOT A UPC
108794 01
Pages referenced in this manual — manufacturer, support and downloads.
What the fault codes shown on the display mean and how to clear them.
| Code | Meaning | Fix | |
|---|---|---|---|
| BD32 | 32" Black Finish | p.21 | |
| BD32B | 32" Brushed Brass Finish | p.21 | |
| BD32P | 32" Platinum Finish | p.21 | |
| BL32 | 32" Refractory Standard Brick Liner Kit | p.21 | |
| PT32 | 32" Perimeter Trim - Black | p.21 | |
| PT32B | 32" Perimeter Trim - Brushed Brass | p.21 | |
| PT32P | 32" Perimeter Trim - Platinum | p.21 | |
| LT32B | 32" Louver Trim Kit - Brushed Brass | p.21 | |
| LT32P | 32" Louver Trim Kit - Platinum | p.21 | |
| SP32 | Smooth Faced Panel Kit- Black | p.21 | |
| SL32 | Stamped Louver Panel Kit- Black | p.21 | |
| RL32 | Rolled Louver Kit- Black | p.21 | |
| FP32 | Filigree Panel Kit- Black | p.21 | |
| FP32B | Filigree Panel Kit- Brushed Brass | p.21 | |
| FP32P | Filigree Panel Kit- Platinum | p.21 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.