UNVENTED (VENT-FREE) GAS COMPACT CLASSIC HEARTH® FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUAL

Shown with Optional Cabinet Mantel/Hearth Base Accessory
REMOTE-READY MODELS: VMH10RNC, VMH10RPC, EFS10RPA AND EFS10RNA
vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS
fied installer, service agency, or the gas supplier.
Save this manual for future reference. For more information, visit www.desatech.com


Due to high temperatures, the appliance should be located out of traffic and away from furni- ture and draperies.
Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.
Fireplace front and screen be- come very hot when running heater. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fire- place will remain hot for a time after shutdown. Allow surfaces to cool before touching.
Carbon Monoxide Poisoning: Early signs of car- bon monoxide poisoning resemble the flu, with head- aches, dizziness, or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once! Have fireplace serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Carefully supervise young chil- dren when they are in the room with fireplace. When using the hand-held remote accessory (Remote-Ready Models Only), keep selector switch in the OFF position to prevent children from turning on burners with remote.
Natural and Propane/LP Gas: Natural and propane/ LP gases are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists. Make certain you read and understand all warn- ings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.
You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is closed before running fireplace.
Keep the appliance area clear and free from combustible ma- terials, gasoline, and other flam- mable vapors and liquids.

Install and use fireplace with care. Follow all lo- cal codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*. *Available from: American National Standards Institute, Inc.
1430 Broadway New York, NY 10018 National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269

UNPACKING
SAFETY PILOT This fireplace has a pilot with an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room fireplaces. The ODS/pilot shuts off the fireplace if there is not enough fresh air.
ELECTRONIC IGNITOR This heater has an electronic ignitor to light heater fuel supply.
THERMOSTATIC HEAT CONTROL FOR THERMOSTAT-CONTROLLED MODELS Thermostat-Controlled models have a thermostat sensing bulb and a control valve. The thermostat will automatically modulate the heat output to maintain a consistent room temperature. This re- sults in greater fireplace comfort. This can also result in lower gas bills.
Remote Selector Switch (Optional)
Figure 1 - Vent-Free Compact Classic

4. Locate four black phillips sheet metal screws from the hardware packet. 5. Rotate hood as shown in Figure 3. Make sure hood tabs point toward fireplace. 6. Insert hood tabs between baffle and louvers (see Figure 3). 7. Gently rotate hood to upright position. Make sure hood tabs are behind louvers and hood is resting on firebox top (see Figure 3). 8. Align screw holes on hood with screw holes on firebox top. 9. Insert screws as shown in Figure 3. Tighten screws firmly.
Figure 3 - Assembling Hood
Figure 2 - Removing Screen

Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the out- side atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and b. weather stripping has been added on
openable windows and doors and c. caulking or sealants are applied to ar- eas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, be- tween wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings. If your home meets all of these three criteria, you must provide additional fresh air. See Ventilation Air From Out- doors, page 8. If your home does not meet all of the three criteria above, proceed to Deter- mining Fresh-Air Flow For Fireplace Lo- cation, page 8.
Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible. While it is good to make your home energy effi- cient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation. Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
Confined and Unconfined Space The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space whose vol- ume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an un- confined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all ap- pliances installed in that space. Rooms communi- cating directly with the space in which the appli- ances are installed*, through openings not fur- nished with doors, are considered a part of the unconfined space. * Adjoining rooms are communicating only if there are doorless passageways or ventilation grills be- tween them.
PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code. ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three fol- lowing ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space The information on pages 7 through 9 will help you classify your space and provide adequate ventilation. The air that leaks around doors and windows may provide enough fresh air for combustion and ven- tilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

The space in the example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide ad- ditional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoin- ing room. If the extra space provides an uncon- fined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building. B. Vent room directly to the outdoors. See Ventila- tion Air From Outdoors. C. Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined. If the actual Btu/Hr used is less than the maximum Btu/ Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless pas- sageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = cu. ft. (volume of space) Example: Space size 16 ft. (length) x 14 ft. (width) x 8 ft. (ceiling height) = 1792 cu. ft. (vol- ume of space) If additional ventilation to adjoining room is sup- plied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.
(volume of space) x 20 = (Maxi- mum Btu/Hr the space can support) Example: 1792 cu. ft. (volume of space) x 20 = 35,840 (maximum Btu/Hr the space can support) 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free fireplace Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr * Do not include direct-vent gas appliances. Di- rect-vent draws combustion air from the outdoors and vents to the outdoors. Example: Gas water heater Btu/Hr Vent-free fireplace + Btu/Hr Total = Btu/Hr 4. Compare the maximum Btu/Hr the space can sup- port with the actual amount of Btu/Hr used.
Ventilation Air From Inside Building This fresh air would come from an adjoining uncon- fined space. When ventilating to an adjoining un- confined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 4, page 9). You can also remove door into adjoining room (see option 3, Fig- ure 4, page 9). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Com- bustion and Ventilation for required size of ventila- tion grills or ducts.
Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent open- ings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used) Example: 35,840 Btu/Hr (maximum the space
can support) 40,000 Btu/Hr (actual amount of Btu/Hr used)
30,000 10,000 40,000

AND VENTILATION
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your pri- mary heat source.
Ventilation Grills Into Adjoining Room,
Or Remove Door into Adjoining
Figure 4 - Ventilation Air from Inside
Inlet Air Ventilated Crawl Space
Figure 5 - Ventilation Air from Outdoors

IMPORTANT: Vent-free fireplaces add moisture to the air. Although this is beneficial, installing fire- place in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 7. Note: Your fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface on the rear, sides, or top of your fireplace, except where stand- off spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing materials. Note: When installing fireplace directly on car- peting, tile or other combustible material, other than wood flooring, the fireplace shall be installed on a metal or wood panel extending the full width and depth of the fireplace. Use the dimensions shown for rough openings to create the easiest installation (see Built-In Fire- place Installation, page 11).
If your fireplace is to be used with an optional mantel, the installation instructions included with your mantel shows an CSA approved method of attaching the fireplace/mantel system to a wall. IMPORTANT: Only use optional cabinet or cor- ner mantels specified in this manual. Purchase the optional mantel from your dealer (see Accesso- ries, page 40). If your fireplace is to be recessed into the wall, see Built-In Fireplace Installation on page 11 to secure your fireplace into the wall.
CHECK GAS TYPE Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.

Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling A. Clearances from the side of the fireplace cabi-
net to any combustible material and wall should follow diagram in Figure 6. Example: The face of a mantel, bookshelf, etc. is made of combustible material and pro- trudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fire- place opening (see Figure 6). B. Clearances from the top of the fireplace
1. Frame in rough opening. Use dimensions shown in Figure 7 for the rough opening. If installing in a corner, use dimensions shown in Figure 8 for the rough opening. The height is 26 7/8" which is the same as the wall opening above. 2. If installing GA3450T blower accessory, do so at this time. Follow instructions included with blower accessory. Note: If not installing blower accessory, you may wish to run electrical wiring to your fire- place for future blower installation (see Ac- cessories, page 40). Use only approved three- wire electrical wiring.
opening to the ceiling should not be less than 36 inches. C. For mantel clearances, see Figure 10 on
page 12.
*Minimum 16 inches from Side Wall
Figure 6 - Minimum Clearance for
BUILT-IN FIREPLACE INSTALLATION Built-in installation of this fireplace involves in- stalling fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. An optional trim kit accessory is available (see Ac- cessories, page 40). Trim will extend past sides of fireplace approximately 1/2 inch. This will cover the rough edges of the wall opening. If installing a built-in mantel above the fireplace, you must follow the clearances shown in Figure 10, page 11. Follow the instructions below to install the fire- place in this manner.
10 1/2"
267/8"
3/4" Off The Floor Minimum
267/8"
Figure 7 - Rough Opening for Installing
365/8" 257/8"
513/4" 267/8"
Figure 8 - Rough Opening for Installing

3. Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equip- ment shutoff valve. The flexible gas line must be the last item installed on the gas piping. 4. If you have not assembled firebox, follow in- structions on page 6. 5. Carefully set fireplace in front of rough open- ing with back of fireplace inside wall opening. 6. Attach flexible gas line to fireplace gas regu- lator. See Connecting Fireplace to Gas Sup- ply, page 19. 7. Bend four nailing flanges on outer casing with pliers (see Figure 9). 8. Attach fireplace to wall studs using nails or wood screws through holes in nailing flange. 9. Check all gas connections for leaks. See Checking Gas Connections, page 19. 10. If using optional trim kit, install the trim after final finishing and/or painting of wall. See instructions included with trim accessory for attaching trim. IMPORTANT: When finishing your firebox, com- bustible materials such as wall board, gypsum board, sheet rock, drywall, plywood, etc. may be butted up next to the sides and top edge of the firebox. Combustible materials should never over- lap the firebox front facing.
Mantel Clearances for Built-In Installation If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.
Nailing Flanges Nails or Wood Screws
Figure 9 - Attaching Fireplace to Wall
Wall Studs · Studs

10. Attach wood base to floor with two 1 3/4" black screws provided (see Figure 12). If the floor is concrete use anchor method (see Attaching Wood Base to Solid Floor, page 17). 11. Install gas line. See Connecting To Gas Sup- ply, page 17. 12. Check for leaks. See Checking Gas Connec- tions, page 19. 13. Place mantel around fireplace. Be careful not to damage wall or mantel. 14. Place trim kit on the shoulder screws located on the side and top of the fireplace. Firmly snap the trim over the shoulder screws on fire- place (see Figure 11). 15. Adjust assembly to remove any gaps. Attach remaining two 3" wood screws from hardware pack through openings inside of fireplace sides into the mantel. The openings are located at top behind the area for the louvers (see Figure 11). 16. Reinstall top louvers.
10" Note: All vertical measurements are from top of fireplace opening to bottom of mantel shelf. All measurements are in inches.
2 1/2"
Shoulder Screws Hole for Attaching Fireplace to Mantel
Figure 10 - Minimum Mantel Clearances
OPTIONAL MANTEL INSTALLATION Note: Refer to instructions provided with the man- tel for assembly instructions. Refer to the follow- ing instructions for system installation. Refer to instructions on page 5 for fireplace assembly. Blower accessory should be installed if it is being used (see Installing Blower Accessory GA3450T, page 14). 1. Unscrew four screws that attach top louver to fireplace. Remove louver from fireplace and set aside. 2. Place fireplace on wood base. 3. Place mantel around fireplace/base assembly. 4. Assemble trim kit. See Assembling Trim, page 14. 5. Firmly snap trim kit on shoulder screws. Shoulder screws are located on fireplace cabi- net (see Figure 11). 6. Align trim kit for flush fit around opening. 7. Use two 3" wood screws provided and attach fireplace base to wooden base. There are holes provided on each side and floor of firebox (see Figure 11). 8. Place base assembly next to wall at installa- tion location. 9. Remove trim kit and mantel. Be careful not to damage wall or mantel.
Shoulder Screws Assembled Trim
Figure 11 - Attaching Trim to Fireplace
1 3/4" Screw
Figure 12 - Attaching Wood Base to

Blower Bracket Mounting Holes
Assembling Trim (Trim shipped with mantel) 1. Remove packaging from three remaining pieces of trim. 2. Locate two adjusting plates with set screws, and two shims in the hardware packet. 3. Align shim under adjusting plate as shown in Figure 13. 4. Slide one end of adjusting plate/shim in slot on mitered edge of top trim (see Figure 13). 5. Slide other end of adjusting plate/shim in slot on mitered edge of side trim (see Figure 13). 6. While firmly holding edges of trim together, tighten both set screws on the adjusting plate with slotted screwdriver. 7. Repeat steps 1 through 6 for other corner. 8. Set assembly aside for later installation.
Figure 14 - Removing Upper Louver
Installing Blower Accessory Note: If you are using a mantel with your fireplace, use the following instructions. If your fireplace is built-in, see For Built-In Installation, page 16.
Figure 13 - Assembling Trim
1. Locate fan switch cover. Remover bottom screw to remove back portion of the cover. 2. Install snap bushings found in hardware kit into both holes in rear of fan switch cover. 3. Make sure the wire harness is firmly con- nected to the terminals on the blower bracket assembly. 4. Note the wire locations on back of AUTO/ OFF/ON switch. The terminals on back of switch are numbered 1, 2, and 3. Carefully remove red wire from terminal 3 and blue wire from terminal 1. Black wire can remain on middle terminal 2 (see Figure 15, page 15). 5. Carefully disconnect green and white wires at their insulated connectors (see Figure 16, page 15).
Removing Upper Louver To install the blower accessory, you must first re- move the upper louver. 1. Lift screen off fireplace and remove log set if installed. 2. Remove 4 screws from upper louver (see Fig- ure 14). Save these screws. 3. Pull upper louver straight out from the cabi- net. Be careful not to scratch the paint. Set louver and screws aside. 4. Open lower louver door by swinging door down (see Figure 15, page 15).

Wire Harness Blower Bracket Assembly
Wiring Routing Hole in Baffle
Front Fan Switch Cover
Red Rear Fan Switch Cover
Figure 15 - Installing Blower (Thermostat Unit Shown)
6. In top of the fireplace cabinet, locate the four mounting holes on the outer casing. Align these four holes with those on the blower bracket assembly. Attach blower bracket as- sembly to the outer casing with 4 #10 screws provided (see Figure 15). 7. Route the wire harness through the hole in left side of baffle. Pull wire harness through lower opening of firebox (see Figure 15). 8. Insert the 4 wire harnesses into one of the round holes in the rear of the fan switch cover and through the rectangular hole on front of the fan switch cover (see Figure 15). 8. Reconnect red wire to switch position 3. Re- connect blue wire to switch position 1. Re- connect green and white wires. 9. Install the switch plate on front of fan switch cover with 2 #10 screws provided (see Fig- ure 17, page 16). Using screw removed in step one, reconnect front and rear of fan switch cover.
110/115 V.A.C.
Figure 16 - Wiring Diagram For Blower

5. Install the switch plate on front of fan switch cover with 2 #10 screws provided (see Figure 17). Using screw removed in step one, reconnect front and rear of fan switch cover. 6. Plug power cord to the outlet receptacle (not provided) as shown in Figure 19, page 17. Wind extra cable of power cord and tie it up with the plastic wire strap (see Figure 19, page 17). Set the cable bundle between the fan switch box and outer casing, away from the burner. 7. Test to make sure the blower is working properly. 8. Reinstall upper louver (see Figure 14, page 14) and close lower louver.
10. Route power cord out of the cabinet by in- serting it through the bushing on the outer cas- ing (see Figure 15, page 15). Plug fan kit into 120-Volt grounded power supply and test op- eration. Note: When switch is in the AUTO position, the fan will start after the fireplace has run for a few moments. The fan will con- tinue to run for several moments after the fire- place has been turned off. When switch is in the ON position, the fan will run until turned to OFF. Reinstall upper louver (see Figure 14, page 14). Close lower louver door.
110/115 V.A.C. Blower
Rear - Fan Switch Cover
Front - Fan Switch Cover
Figure 17 - Installing Switch Plate to Fan
1. Locate fan switch cover. Remove bottom screw to remove back portion of the cover (see Figure 17). 2. Install a snap bushing found in hardware kit into one of the holes on rear of fan switch cover. The other hole is for a strain relief clamp (not supplied) to secure incoming electrical supply. 3. Follow steps 3 through 7 in Installing Blower Accessory, page 14. 4. A licensed electrician must follow the wiring diagram to connect incoming electrical sup- ply to fan kit wiring harness (see Figure 18).
Figure 18 - Wiring Diagram For Blower
Extension Cord Use extension cord if needed. The cord must have a three-prong, grounding plug and a three-hole recep- tacle. Make sure cord is in good shape. It must be heavy enough to carry the current needed. An under- sized cord will cause a drop in line voltage. This will result in loss of power and overheating. Use a No. 16 AWG cord for lengths less than 50 feet.

Clamp Connector (not included)
Plastic Wire Strap Wire Harness
Outlet Receptacle (not included)
Figure 19 - Installing Blower (Thermostat Unit Shown)
ATTACHING WOOD BASE TO SOLID FLOOR For attaching base to solid floors (concrete or masonry) Note: Floor anchors and mounting screws are in hardware package. The hardware package is pro- vided with fireplace. 1. Drill holes at marked locations using 5/16" drill bit. For solid floors (concrete or ma- sonry), drill at least 1" deep. 2. Fold floor anchor as shown in Figure 20. 3. Insert floor anchor (wings first) into hole. Tap anchor flush to floor. 4. Insert mounting screws through base and into floor anchors. 5. Tighten screws until base is firmly fastened to floor.
Figure 20 - Folding Anchor

We recommend that you install a sediment trap in supply line as shown in Figure 22, page 18. Lo- cate sediment trap where it is within reach for cleaning. Install in piping system between fuel sup- ply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.
For propane/LP units, the installer must supply an external regulator. The external regulator will re- duce incoming gas pressure. You must reduce in- coming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pres- sure, fireplace regulator damage could occur. In- stall external regulator with the vent pointing down as shown in Figure 21. Pointing the vent down protects it from freezing rain or sleet.
Figure 21 - External Regulator With Vent
CSA Design- Certified Equipment Shutoff Valve With 1/8" NPT Tap*
Propane/LP From External Regulator (11" W.C.** to 14" W.C. Pressure)
Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figures 22). IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance. Check your building codes for any special require- ments for locating equipment shutoff valve to fire- places. Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from go- ing into pipe. Excess sealant in pipe could result in clogged fireplace valves.
Approved Flexible Gas Line
NATURAL From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)
Pipe Nipple Cap Tee Joint
Figure 22 - Gas Connection
* Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Ac- cessories, page 40.

To Gas Regulator (Thermostat-Controlled Models) or Control Valve (Remote-Ready Models)
➞
PROPANE/LP To External Regulator
Flexible Gas Line from Fireplace Gas Regulator Provided With Fireplace
NATURAL To Gas Supply
Figure 23 - Attaching Flexible Gas Line
to Equipment Shutoff Valve
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in ex- cess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equip- ment shutoff valve was connected.
Equipment Shutoff Valve

Gas Regulator or Gas Control Valve
Figure 26 - Checking Gas Joints (Natural
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 24). 2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve lo- cated on or near gas meter for natural gas, or using compressed air. 3. Check all joints from gas meter to equipment shutoff valve for natural gas or propane/LP supply to equipment shutoff valve for pro- pane/LP (see Figures 25 or 26). Apply non- corrosive leak detection fluid to all joints. Bubbles forming show a leak. 4. Correct all leaks at once.
PRESSURE TESTING FIREPLACE GAS CONNECTIONS 1. Open equipment shutoff valve (see Figure 24). 2. Open main gas valve located on or near gas meter for natural gas or open propane/LP sup- ply tank valve. 3. Make sure control knob of fireplace is in the OFF position. 4. Check all joints from equipment shutoff valve to gas regulator (Thermostat-Controlled Mod- els), or to gas control valve (Remote-Ready Models) (see Figures 25 or 26). Apply non- corrosive leak detection fluid to all joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light fireplace (see Operating Fireplace, page 23). Check all other internal joints for leaks. 7. Turn off fireplace (see To Turn Off Gas to Ap- pliance, page 25 for Thermostat-Controlled Models or page 27 for Remote-Ready Models).
OFF POSITION
Figure 24 - Equipment Shutoff Valve
Gas Regulator or Gas Control Valve
Figure 25 - Checking Gas Joints

OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL ACCESSORIES Remote-Ready Models Only (GHRCB Series & GHRCTB Series) Installing Receiver 1. Disconnect jumper wire from control valve (see Figure 27). 2. Locate battery clip mounted on back of re- ceiver (see Figure 28). 3. Slide 9-volt battery (not included) through clip. 4. Attach terminal wires to battery (see Figure 29). 5. Connect wires from remote receiver to con- trol valve as shown in Figure 29. 6. Install remote receiver unit onto remote/ blower bracket using screws provided (see Figure 29).
Red Wire to TPTH Terminal on Control Valve
White Wire to TH Terminal on Control Valve
Figure 29 - Installing Remote Receiver
Installing 9-Volt Battery in Hand-Held Remote Control Unit 1. Remove battery cover on back of remote con- trol unit. 2. Attach terminal wires to the battery (not in-
cluded). Place battery into the battery housing. 3. Replace battery cover onto remote control unit.
Figure 27 - Disconnecting Wires From
Remote Control Unit Battery Housing
Figure 30 - Installing Battery in Hand- Held Remote Control Unit (GHRCB and
Terminal Wires 9-Volt Battery
Figure 28 - Attaching Battery to Receiver
Figure 31 - Installing Battery in Hand- Held Remote Control Unit (GHRCTB and

1. Disconnect jumper wire from control valve (see Figure 32). 2. Connect one terminal of 25 ft. wire to "TPTH" terminal on control valve (see Figure 32). 3. Connect remaining wire terminal to the “TH” terminal on the control valve. Make sure that wire terminals are in the positions on your unit as pictured in Figure 32. 4. Route the 25 ft. wire to a convenient location to mount your thermostat (no outside wall). IMPORTANT: The wire may be shortened but must not be lengthened. The thermostat should be mounted 54" above the floor in a location where there is good air circulation. Avoid heat sources such as lamps, direct sunlight, fireplace, or heat and air con- ditioning ducts. 5. Gently remove the cover of the thermostat from the base. Grasp the sides of the cover firmly and pull to separate from the base. 6. Feed the electrical wires through the rectangu- lar slots on each side of the base (see Figure 33).
One terminal of 25 ft. wire
Figure 32 - Connecting Wire Terminals
Feed wires through rectangular slots
Figure 33 - Back View of Thermostat
Figure 34 - Thermostat Base Terminals

Figure 35 - Installing Log and Screen
MODELS
FOR YOUR SAFETY READ BEFORE LIGHTING
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the
INSTALLING LOG SET AND SCREEN 1. Remove log packaging material and discard packaging. Gently place log over the burner (see Figure 35). Do not allow log to contact flame. If flame contacts log, soot will be created. 2. Reattach screen by placing the notches in the screen frame over the shoulder screws and pushing down.
gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.
Shoulder Screw · Continued Log · Screen

Note: If pilot does not stay lit, refer to Troubleshooting, page 31. Also, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure on page 25. 7. Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. Note: If pilot goes out, repeat steps 3 through 7. This fireplace has a safety inter- lock system. Wait one (1) minute for sys- tem to reset before lighting pilot again. 8. Turn control knob counterclockwise
D. Do not use this appliance if any part has
been under water. Immediately call a quali- fied service technician to inspect the appli- ance and to replace any part of the control system and any gas control which has been under water.
C-clockwise to desired heating level. The burner should light. Set control knob to any heat level between 5 (high) and 1 (low).
Electronic Ignitor Button Control Knob
1. STOP! Read the safety information above. 2. Make sure equipment shutoff valve is fully open. 3. Turn control knob clockwise Clockwise to the OFF position. 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise C-clockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 36). Note: You may be running this fireplace for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system. • If control knob does not pop out when released, contact a qualified service per- son or gas supplier for repairs. 6. With control knob pressed in, press and release ignitor button (see Figure 36). This will light pilot. The pilot is attached to the front burner. If needed, keep pressing igni- tor button until pilot lights.
Figure 36 - Control Knob In The OFF
Figure 37 - Natural Gas Pilot
Thermocouple Ignitor Electrode Pilot Burner
Figure 38 - Propane/LP Gas Pilot
Position · Thermocouple Ignitor Electrode · Pilot Burner

to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases. Note: It is safe to operate fireplace with blower turned off. However, the blower helps distrib- ute heated air from the fireplace.
TO APPLIANCE
Shutting Off Fireplace 1. Turn control knob clockwise Clockwise to the OFF position. 2. Turn off all electric power to the appliance (if applicable) if service is to be performed.
Shutting Off Burners Only (pilot stays lit) Turn control knob clockwise Clockwise to the PI- LOT position.
OPERATION The thermostat used on this fireplace senses the room temperature. At times the room may ex- ceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between 1 and 5. Note: The thermostat sensing bulb measures the air near the fireplace cabinet. This may not always agree with room temperature (depend- ing on housing construction, installation loca- tion, room size, open air temperatures, etc.). Frequent use of your fireplace will let you de- termine your own comfort levels.
Figure 39 - AUTO/OFF/ON Blower Switch
FOR YOUR SAFETY READ BEFORE LIGHTING
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the
PROCEDURE 1. Follow steps 1 through 5 under Lighting In- structions, page 24. 2. With control knob pressed in, strike match. Hold match to pilot until pilot lights. 3. Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instructions, page 24.
BLOWER This blower has three settings: ON, OFF, and AUTO. In the ON position, the blower will op- erate constantly. In the OFF position, the blower will not operate. In the AUTO position, the blower will start when the thermostat senses a sufficient increase in firebox temperature. Note: Your fireplace and thermostat blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates
gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.
AUTO/OFF/ ON Switch

light pilot. The pilot is attached to the front of the burner. If needed, keep pressing ig- nitor button until pilot lights. Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 27. 7. Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. • If control knob does not pop out when re- leased, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8. 8. Slightly push in and turn control knob coun- terclockwise C-clockwise to the ON position.
D. Do not use this appliance if any part has
been under water. Immediately call a quali- fied service technician to inspect the appli- ance and to replace any part of the control system and any gas control which has been under water.
Control Knob Electronic Ignitor
N
O
T
P
F
F
O
Figure 40 - Control Knob and Ignitor Button Location (Shown as Supplied -
Ignitor Electrode Pilot Burner
Clockwise to the OFF position (see Figure 40). 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, column 2, page 25. If you don’t smell gas, go to the next step. 5. Press in and turn control knob counter- clockwise C-clockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 40). Note: You may be running this fireplace for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system. 6. With control knob pressed in, press and re- lease electronic ignitor button. This will
Figure 41 - Propane/LP Gas Pilot
Ignitor Electrode Pilot Burner
Figure 42 - Natural Gas Pilot
No Control Options)

1. After lighting, let pilot flame burn for about one minute. Turn control knob to ON posi- tion. Slide the remote selector switch to the REMOTE position (see Figure 43). Note: The burner may light if hand-held remote was on when the remote selector switch was last turned off. You can now turn the burner on and off with the hand-held re- mote control unit. IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.
TO APPLIANCE
Shutting Off Fireplace 1. Turn control knob clockwise Clockwise to the OFF position. 2. If Using Optional Hand-Held Remote: Set remote switch to the OFF position to pre- vent draining battery.
Shutting Off Burner Only (pilot stays lit) You may shut off the burner and keep the pilot lit by doing one of the following: 1. Turn control knob clockwise Clockwise to the PILOT position. 2. If Using Optional Hand-Held Remote: Use remote control manual OFF button.
Selector Switch in REMOTE Position (Optional Hand-Held Remote Control) Electronic Ignitor
N
O
T
O
O
P
F
F
Figure 43 - Setting the Selector Switch and Control Knob for Hand-Held Remote
PROCEDURE 1. Follow steps 1 through 5 under Lighting Instructions, page 26. 2. Depress control knob and light pilot with match. 3. Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instructions, page 26.
ON/OFF SERIES (MODEL GHRCB) Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 44).
TO LOCK press both buttons on hand-held re- mote control until light stops flashing. Hand- held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.
TO UNLOCK press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked.
REMOTE OPERATION Note: All remote control accessories must be purchased separately (see Accessories, page 40). Follow instructions included with the re- mote control.
Control Button Turns Burners On and Off
Figure 44 - On/Off Hand-Held Remote
Control Knob · Operation · Control Unit (GHRCB)

Key Pad Lock Feature This feature allows the user to lock/unlock the keypad on the hand-held remote in the MANU or AUTO mode to prevent inadvertent opera- tion (i.e. children operating the hand-held re- mote control, etc.). The keypad is locked in ei- ther on or off. Press the POWER and LOCK buttons together to turn the unit on or off.
THERMOSTAT SERIES (MODEL GHRCTB) The hand-held remote can be operated using either the manual mode (MANU) or thermo- static mode (AUTO) (see Figure 45). To select Fahrenheit/Centigrade mode display, carefully press the ˚C/˚F mode button with the end of a paper clip or similar blunt object.
Turns Hand- Held Remote On or Off and Allows You to Choose the Manual Setting
Digital Display Shows Temperature and Settings
Manual Mode 1. Press the POWER and LOCK buttons to- gether to turn on the hand-held remote control. 2. Press the MANU button to turn on the fireplace. 3. Press the POWER and LOCK buttons to- gether to turn off the fireplace.
Turns Burners On or Off
Decreases Room Temperature in AUTO Mode
Increases Room Temperature in AUTO Mode
Auto (Thermostatic) Mode 1. Press the POWER and LOCK buttons to- gether to turn on the hand-held remote control. 2. Press AUTO button to select this mode. 3. Set the desired room temperature by press- ing the TEMP + or - buttons. 4. Press the POWER and LOCK buttons to- gether to turn off the fireplace Note: Do not leave the hand-held remote in the AUTO mode close to the fireplace. The radiant heat from the fireplace will turn off the fire- place. Ideally, place the hand-held remote in the center of the room facing towards the fireplace. Note: Do not hold the hand-held remote for a long time. Body temperature will affect its op- eration in the AUTO mode.
Locks System to Prevent Accidental Ignition
Figure 45 - Thermostat Hand-Held
Remote Control Unit (GHRCTB)
GWMT1 WALL MOUNTED THERMOSTAT (OPTIONAL) Make sure the heater switch is on REMOTE and set the temperature adjustment on wall thermostat to the desired setting. The thermo- stat has been electronically calibrated at the fac- tory and requires no adjustment or leveling. Upon installation, the thermostat must be al- lowed to stabilize at room temperature for a minimum of 30 minutes for proper operation. See installation instructions on page 22 of this manual.
Safety Features When away from home for an extended period of time or as a child safety feature to prevent acci- dental ignition of the fireplace, receiver ON/OFF/ REMOTE switch should be in the OFF position.
SWITCH (OPTIONAL) Make sure the heater switch is on REMOTE. This wall switch works just like the conven- tional light switch. Flip the switch up for on and down for off. Note: Make sure that this switch is not in a po- sition to be mistaken for a light switch. This may result in the fireplace being inadvertently turned on without the proper precautions be- ing taken. See installation instructions on page 23 of this manual.
Auto Shutoff Feature 1. If the average room temperature exceeds 82 degrees Fahrenheit (28 degrees Centigrade), the hand-held remote control will perform a safety override and shut the fireplace off. This feature is not available in the MANU mode. 2. The receiver continuously receives signals from the hand-held remote to control the room temperature. If the hand-held remote is misplaced, obstructed, or for any reason cannot transmit to the receiver, the receiver will shut off the fireplace after 8 minutes.
Selects Auto Setting

BLOWER This blower has three settings: ON, OFF, and AUTO. In the ON position, the blower will op- erate constantly. In the OFF position, the blower will not operate. In the AUTO position, the blower will start when the thermostat senses a sufficient increase in firebox temperature. Note: Your fireplace and thermostat blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases. Note: It is safe to operate fireplace with blower turned off. However, the blower helps distrib- ute heated air from the fireplace.
Figure 47 - Correct Pilot Flame Pattern
Figure 48 - Incorrect Pilot Flame Pattern
Figure 46 - AUTO/OFF/ON Blower Switch
Check pilot flame pattern and burner flame pat- terns often.
Figure 49 - Correct Burner Flame Pattern
Figure 50 - Incorrect Burner Flame

4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle. 5. Blow air into the primary air holes on the in- jector holder. 6. In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4. Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot as- sembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figures 52 or 53 depend- ing on model). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.
Primary Air Inlet Holes
Figure 51 - Injector Holder On Outlet
BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have fireplace inspected yearly by a qualified service person. We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using com- pressed air no greater than 30 PSI. Your local com- puter store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 51). 3. Blow air through the ports/slots and holes in the burner.
Pilot Air Inlet Hole
Figure 52 - Pilot Inlet Air Hole
Pilot Air Inlet Hole
Figure 53 - Pilot Inlet Air Hole
Air Passageways • Use a vacuum cleaner or pressurized air to clean.
Exterior • Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no spark at ODS/pilot
When ignitor button is pressed, there is spark at ODS/pilot but no ignition

POSSIBLE CAUSE
REMEDY
ODS/pilot lights but flame goes out when control knob is released
B) Clean ODS/pilot (see Cleaning and Maintenance, page 30) or replace ODS/pilot assembly
Burner does not light after ODS/ pilot is lit
Delayed ignition of burner
Burner backfiring during com- bustion

POSSIBLE CAUSE
REMEDY
Slight smoke or odor during ini- tial operation
Fireplace produces a whistling noise when burner is lit
White powder residue forming within burner box or on adjacent walls or furniture
Moisture/condensation noticed on windows

POSSIBLE CAUSE
REMEDY
Remote does not function (Re- mote-Ready Models Only)
Fireplace produces a clicking/ ticking noise just after burners are lit or shut off
Fireplace produces unwanted odors
Fireplace shuts off in use (ODS operates)
Gas odor even when control knob is in OFF position
Gas odor during combustion

VMH10TPC VMH10RPC VMH10TNC VMH10RNC EFS10TPA EFS10RPA EFS10TNA EFS10RNA Btu/Hr 10,000 Type Gas Propane/LP Propane/LP Natural Natural Ignition Electronic Ignitor Electronic Ignitor Electronic Ignitor Electronic Ignitor Manifold Pressure 8.5" W.C. 8" W.C. 3" W.C. 3.5" W.C. Inlet Gas Pressure (in. of water) Maximum 14" 14" 10.5" 10.5" Minimum* 11" 11" 5" 5" Dimensions, inches (HxWxD) Fireplace 25 7/8 x 26 13/16 x 9 3/8 (including hood and screws) Carton 32 5/8 x 27 13/16 x 11 5/8 Weight, pounds Fireplace 44 1/2 lbs. 44 1/2 lbs. 44 1/2 lbs. 44 1/2 lbs. Shipping 48 lbs. 48 lbs. 48 lbs. 48 lbs. * For purpose of input adjustment
REPLACEMENT PARTS
Gas Control TPTH TH
SERVICE HINTS
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready. You can also visit DESA Heating Products’ tech- nical services web site at www.desatech.com.
Jumper Wire · Red · White Thermopile



THERMOSTAT-CONTROLLED MODELS This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 35 of this manual.
PART NUMBERS KEY VMH10TPC VMH10TNC NO. EFS10TPA EFS10TNA DESCRIPTION QTY.
1 102633-02 102633-02 Outer Casing Top 1 2 102624-02 102624-02 Outer Casing 1 3 099230-02 099230-02 Shoulder Screw 14 4 098304-01 098304-01 Screw, #10-16 x 3/8" 4 5 112066-01 112066-01 Burner 1 6 103209-05 103209-05 Extruded Louver 2 7 102635-02 102635-02 Left and Right Side Front 2 8 M11084-26 M11084-26 Hex Head Screw, #10-16 x 3/8" 39 9 111725-03 111725-03 Pilot Bracket 1 10 104281-01CK 104281-01CK Firebox Hood 1 11 102638-01 102638-01 Firebox Top 1 12 104286-01 104285-01 ODS/Pilot Assembly 1 13 ** ** Firebox Wrapper 1 14 099211-01 099211-01 Control Bracket Screw 2 15 112070-01 112070-01 Inlet Tube 1 16 112071-01 112071-01 Burner Tube 1 17 112067-01 112067-01 Electronic Ignitor Bracket 1 18 M11084-38 M11084-38 Screw #8-18 x 3/8 3 19 104335-01CK 104335-01CK Outer Shell Base 1 20 ** ** Firebox Floor 1 21 099415-04 099415-10 Gas Regulator 1 22 099123-01 099123-01 Thermobulb Clip 2 23 111435-01 111435-01 Electronic Ignitor 1 24 099387-13 099387-13 Pilot Tube 1 25 098271-10 098271-10 Ignitor Cable 1 26 098249-01 098249-01 Nut, M5 2 27 101004-13 101004-12 Injector 1 28 098522-27 098522-27 Gas Valve 1 29 102639-01 102639-01 Baffle 1 30 101628-03 101628-03 Flexible Connector 1 31 102869-01 102869-01 Control Bracket 1 32 100587-01 100587-01 Screw, 6-20 x .38 4 33 103295-06CK 103295-06CK Screen Assembly 1 34 112750-01 112750-01 Log Set 1 35 104313-01 104313-01 Hinge Pin (Right) 1 36 104313-02 104313-02 Hinge Pin (Left) 1 37 M10908-2 M10908-2 Hinge Screws 4 38 112068-01 112068-01 Fan Switch Box 1 39 112069-01 112069-01 Fan Switch Cover 1 40 097809-03 097809-03 3/8" NPT x 3/8" Flare Brass Fitting 1 41 101629-02 101629-02 Bushing 1
101054-01 101054-01 Lighting Instructions Plate 1 100563-01 100563-01 Warning Plate 1 103470-01 103470-01 Hardware Package 1
** Part not available for field replacement.



REMOTE-READY MODELS This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 35 of this manual.
PART NUMBERS KEY VMH10RPC VMH10RNC NO. EFS10RPA EFS10RNA DESCRIPTION QTY. 1 102633-02 102633-02 Outer Casing Top 1 2 102624-02 102624-02 Outer Casing 1 3 099230-02 099230-02 Shoulder Screw 14 4 098304-01 098304-01 Screw, #10-16 x 3/8" 4 5 112066-01 112066-02 Burner 1 6 103209-05 103209-05 Extruded Louvered 2 7 102635-02 102635-02 Left and Right Side Front 2 8 100587-01 100587-01 Screw, 6-20 x 3/8" 4 9 104281-01CK 104281-01CK Firebox Hood 1 10 102638-01 102638-01 Firebox Top 1 11 103778-01 103779-01 ODS/Pilot Assembly 1 12 ** ** Firebox Wrapper 1 13 112415-01 112415-01 Burner Tube 1 14 104335-01CK 104335-01CK Outer Shell Base 1 15 112067-01 112067-01 Electronic Ignitor Bracket 1 16 111435-01 111435-01 Electronic Ignitor 1 17 — 099918-02 Regulator, Pilot 1 18 098271-10 098271-10 Ignitor Cable 1 19 101004-13 101004-12 Injector 1 20 M11084-26 M11084-26 Screw, Hex Head, #10-16 x 3/8" 36 21 108135-02 108135-02 Valve Bracket 2 22 103781-04 103781-03 Gas Valve 1 23 102639-01 102639-01 Baffle 1 24 101628-01 101628-01 Flexible Connector 1 25 098249-01 098249-01 Nut, M5 2 26 103295-06CK 103295-06CK Screen Assembly 1 27 112750-01 112750-01 Log Set 1 28 104313-01 104313-01 Right Hinge 1 29 104313-02 104313-02 Left Hinge 1 30 M10908-2 M10908-2 Hinge Screws 4 31 M11084-38 M11084-38 Hex Screw, AB 8-18 x 3/8" 1 32 M12461-26 M12461-26 Screw, 10-32 x 3/8" 4 33 099058-04 099058-04 Connector, Male 1 34 ** ** Firebox Floor 1 35 101629-02 101629-02 Bushing 1 36 112068-01 112068-01 Fan Switch Box 1 37 112069-01 112069-01 Fan Switch Cover 1 38 097809-03 097809-03 Male Fitting 1 39 — 100609-01 Pilot Tube to Regulator 1 40 099387-13 099387-15 Pilot Tube to Control Valve 1 41 111725-03 111725-03 Pilot Bracket 1
101054-01 101054-01 Lighting Instructions Plate 1 100563-01 100563-01 Warning Plate 1 103470-01 103470-01 Hardware Package 1
** Part not available for field replacement.

THERMOSTAT-CONTROLLED BLOWER KIT GA3450T SERIES For all models. Provides better heat distribution. Makes fireplace more efficient. Automatically turns off and on as needed.
Purchase these fireplace accessories from your lo- cal dealer. If they can not supply these accessories, call DESA Heating Products at 1-866-672-6040 for referral information. You can also write to the ad- dress listed on the back page of this manual.
EQUIPMENT SHUTOFF VALVE GA5010 For all models. Equipment shutoff valve with 1/ 8" NPT tap. Fits 1/2" NPT pipe.
BRASS EXTRUDED LOUVER KIT GA9092 For all models. These louvers will give your fire- place the elegant look of brass and allows you to customize your fireplace. They easily replace the standard black louvers by screwing into place.
PLATINUM EXTRUDED LOUVER KIT GAP9092 For all models. These louvers will give your fire- place the elegant look of platinum and allows you to customize your fireplace. They easily replace the standard black louvers by screwing into place.
BRASS TRIM KIT - GA6095 For all models. Optional four-sided brass trim kit for recessed built-in installations (when unit is raised off of the floor). Provides a finished appear- ance by covering rough edges of wall opening.
BRASS TRIM KIT - GA6094 (Not Shown) For all models. Optional three-sided brass trim kit for custom and recessed installations (when unit is on the floor). Provides a finished appearance by covering rough edges of wall opening.
PLATINUM TRIM KIT - GAP6094 (Not Shown) For all models. Optional three-sided platinum trim kit for custom and recessed installations (when unit is on the floor). Provides a finished appearance by covering rough edges of wall opening.
GMC61U Series - Unfinished GMC60F Series - Oak Finished GMC65W Series - White Lacquer Finished (Appearance May Differ by Model) For all models. A mantel and hearth base offers compact styling and completes the fireplace look. Available in an oak stained or an unfinished birch, ready to stain or paint. Complete assembly instruc- tions included. Three-sided trim kit included.
BLACK TRIM KIT - GAB6094 (Not Shown) For all models. Optional three-sided black trim kit for custom and recessed installations (when unit is on the floor). Provides a finished appearance by covering rough edges of wall opening.

WALL-MOUNT THERMOSTAT SWITCH GWMT1 (Not Shown) For all Remote-Ready Models. The desired com- fort setting can be selected on the wall thermostat and the fireplace will automatically cycle from pi- lot to the heat setting selected.
WALL-MOUNT ON/OFF SWITCH - GWMS2 (Not Shown) For all Remote-Ready Models. Allows the fire- place to be turned on and off with a wall switch.
GMC63U Series - Unfinished GMC64F Series - Finished GMC83F Series - Oak Stain Finished For all models. Space-saving mantel and hearth base corner design features clean, classic lines. Available in a stained oak, white lacquer or an un- finished hardwood, ready to stain or paint. Com- plete assembly instructions included. Three-sided trim kit included.
RECEIVER AND HAND-HELD THERMOSTAT REMOTE CONTROL KIT - GHRCTB For all Remote-Ready Models. Allows the fire- place to be operated in a manually or thermostati- cally controlled mode. You can turn the fireplace on and off without ever leaving the comfort of your easy chair.
RECEIVER AND HAND-HELD REMOTE CONTROL KIT - GHRCB For all Remote-Ready Models. Allows the fire- place to be turned on and off by using a hand-held remote control.
GMC80F Series - Oak Finished GMC81U Series - Unfinished Birch GMC82F Series - Cherry Finished Birch For all models. Mantel features columns, mold- ings, fluting and medallion. Dimensions (WxHxD): 56" x 50" x 24"
INFORMATION VIDEO - 108917-01 For all models. A care and maintenance video is available by calling 1-866-672-6040. You may also email your request to www.productsupport@desaint.com.
CLEANING KIT - GCK (Not Shown) For all models. Your vent-free gas appliance re- quires regular cleaning and maintenance to pre- vent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.
FIRE CRACKLE - CF6A (Not Shown) For all models. Creates the sound of a real burn- ing fire.



Serial No
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
VENT-FREE COMPACT CLASSIC HEARTH ® FIREPLACE
DESA Heating Products warrants this product to be free from defects in materials and components for four (4) years and five (5) years on stainless steel burners from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this fireplace to proper operating condition and an allowance for labor when provided by a DESA Heating Products Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA Heating Products who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The fireplace MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EX- PRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR (4) YEARS ON ALL COMPONENTS AND FIVE (5) YEARS ON STAINLESS STEEL BURN- ERS FROM THE DATE OF FIRST PURCHASE; AND DESA HEATING PRODUCTS’ LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA HEATING PRODUCTS SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, IN- CIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com
112462-01 Rev. B 04/04 NOT A UPC
Model Date Purchased 112462 01