Instruction/ maintenance manual of the product M36E, M42E, VM36E, VM42E Desa
Go to page of 26
MODELS M36E(B,H), M42E(B,H), VM36E(B,H) AND VM42E(B,H) ELECTRONIC IGNITION - NA TURAL GAS This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. This appliance is only for use with the type of gas indicated on the rating plate.
108796-01D 2 For more information, visit www.desatech.com For more information, visit www.desatech.com TABLE OF CONTENTS SAFETY INFORMA TION ............................................................ 2 UNP ACKING ....................................
108796-01D 3 3 For more information, visit www.desatech.com For more information, visit www.desatech.com SAFETY INFORMATION UNPACKING 7. A hearth extension is not required with this appliance. If one is installed, it is for aesthetic purposes only and does not have to meet the standard requirements.
108796-01D 4 For more information, visit www.desatech.com For more information, visit www.desatech.com GAS RATING - NATURAL M36E(B,H)/VM36E(B,H) M42E(B,H)/VM42E(B,H) Max. Input Rating: 40,000 Btu/Hr 45,000 Btu/Hr Manifold Pressure: 3.5 in. WC (.87 kPa) 3.
108796-01D 5 5 For more information, visit www.desatech.com For more information, visit www.desatech.com PRODUCT SPECIFICATIONS S T P Q R X Outside Air Kit Location (Optional) K 7" J I M L P V 13.
108796-01D 6 For more information, visit www.desatech.com For more information, visit www.desatech.com CLEARANCES Minimum clearances to combustibles are: • Back and Sides of Outer Surround ............................ 0" min. • Drywall to Sides of Front Face (Nailing Flanges) .
108796-01D 7 7 For more information, visit www.desatech.com For more information, visit www.desatech.com MANTEL CLEARANCES AND WALL DETAILS A combustible mantle shelf maybe installed a maximum 12 " (229 mm) from the wall.
108796-01D 8 For more information, visit www.desatech.com For more information, visit www.desatech.com PRE-INST ALLA TION PREP ARA TION Continued PRE-INSTALLATION PREPARATION Framing Installing Transition Vent Collar FRAMING 1. Frame appliance enclosure as illustrated in Figures 7 and 8.
108796-01D 9 9 For more information, visit www.desatech.com For more information, visit www.desatech.com VENTING INST ALLA TION A B-type venting system must be connected to the appliance for venting to the outside of the building. The following section is provided as a guide to a standard B-type vent installation.
108796-01D 10 For more information, visit www.desatech.com For more information, visit www.desatech.com CHECKING FOR PROPER VENTING After completing and checking the electrical, gas and vent connec- tions, follow the lighting instructions and allow the main burner to run for approximately 5 minutes.
108796-01D 11 11 For more information, visit www.desatech.com For more information, visit www.desatech.com INST ALLA TION INSTALLATION Wall Switch Installation Optional Remote Control Installation Gas.
108796-01D 12 For more information, visit www.desatech.com For more information, visit www.desatech.com EMBER AND PAN MATERIAL PLACEMENT 1. Open the bag(s) of vermiculite and fill the entire burner pan until the burner tube is completely covered (see Figure 20).
108796-01D 13 13 For more information, visit www.desatech.com For more information, visit www.desatech.com LOG PLACEMENT FOR M36E/VM36E MODELS 1. Place small front right log (log 1) on right front of grate as shown in Figure 23. 2. Place large back log (log 2) onto grate making sure notches rest over grate as shown in Figure 23.
108796-01D 14 For more information, visit www.desatech.com For more information, visit www.desatech.com INST ALLA TION Continued LOG PLACEMENT FOR M42E/VM42E MODELS 1. Place log 1A on the front left side of grate. Place log 1B on the front right side of the grate.
108796-01D 15 15 For more information, visit www.desatech.com For more information, visit www.desatech.com COMBUSTION AIR KIT MODEL AK4 (OPTIONAL) The outside air kit may be installed on the left side of the fireplace only. The vent can be installed through the outside wall or a ventilated crawl space.
108796-01D 16 For more information, visit www.desatech.com For more information, visit www.desatech.com 5. Once the top and bottom pins are secured, unfold the door into the closed position. 6. Repeat the process for the opposite door assembly . 7. T o adjust the doors, slide them partially open.
108796-01D 17 17 For more information, visit www.desatech.com For more information, visit www.desatech.com Figure 37 - Turning Equipment Shutoff Valve to the OFF Position TO TURN OFF GAS TO APPLIANCE 1. T urn off the wall switch. 2. T urn off all electric power to the appliance if service is to be perf ormed.
108796-01D 18 For more information, visit www.desatech.com For more information, visit www.desatech.com CLEANING AND MAINTENANCE WARNING: The logs can be hot. Handle only when cool. WARNING: Turn off gas and electrical power before servicing appliance.
108796-01D 19 19 For more information, visit www.desatech.com For more information, visit www.desatech.com Robertshaw MODEL SP745 IGNITION CONTROL STEP DOWN TRANSFORMER PV GND PV/MV TR MV TH VENT SAFE.
108796-01D 20 For more information, visit www.desatech.com For more information, visit www.desatech.com TROUBLESHOOTING The two most common causes of a malfunctioning gas appliance are: 1.
108796-01D 21 21 For more information, visit www.desatech.com For more information, visit www.desatech.com TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
108796-01D 22 For more information, visit www.desatech.com For more information, visit www.desatech.com ILLUSTRA TED P AR TS BREAKDOWN M36E(B,H),M42E(B,H), VM36E(B,H) AND VM42E(B,H) MODELS ILLUSTRATED.
108796-01D 23 23 For more information, visit www.desatech.com For more information, visit www.desatech.com KEY M36E(B,H) M42E( B, H) NO. VM36E(B,H) VM42E(B,H) DESCRIPTION QTY.
108796-01D 24 For more information, visit www.desatech.com For more information, visit www.desatech.com ILLUSTRA TED P AR TS BREAKDOWN LOGS FOR M36E(B,H),M42E(B,H), VM36E(B,H) AND VM42E(B,H) MODELS 6 4 1A 1B 3 5 2 Logset for M36E(B,H) and VM36E(B,H) Models Logset for M42E(B,H) and VM42E(B,H) Models KEY PART NO.
108796-01D 25 25 For more information, visit www.desatech.com For more information, visit www.desatech.com ACCESSORIES AIR KIT AK4 - Optional kit helps offset the negative pressure often existing in today's tightly constructed homes.
108796-01D 26 For more information, visit www.desatech.com For more information, visit www.desatech.com LIMITED WARRANTY B-VENT FIREPLACE DESA International warrants this product to be free from defec.
An important point after buying a device Desa M36E, M42E, VM36E, VM42E (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Desa M36E, M42E, VM36E, VM42E yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Desa M36E, M42E, VM36E, VM42E - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Desa M36E, M42E, VM36E, VM42E you will learn all the available features of the product, as well as information on its operation. The information that you get Desa M36E, M42E, VM36E, VM42E will certainly help you make a decision on the purchase.
If you already are a holder of Desa M36E, M42E, VM36E, VM42E, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Desa M36E, M42E, VM36E, VM42E.
However, one of the most important roles played by the user manual is to help in solving problems with Desa M36E, M42E, VM36E, VM42E. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Desa M36E, M42E, VM36E, VM42E along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center