Instruction/ maintenance manual of the product DVF36CR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP Desa
Go to page of 36
For more information, visit www .desatech.com W ARNING: If the information in this manual is not fol- .
www .desatech.com 1 12108-01C 2 T AbLE OF CONTENTS Safety Information ............................................... 2 Dimensions .......................................................... 5 Pre-Installation Preparation ..............................
www .desatech.com 1 12108-01C 3 Modles (V)DVF36TCRE, (V)DVF36TCRPE, (V)DVF36TCLE and (V)DVF36TCLPE use a direct spark ignition with a 24 V AC control mod- ule. All models have HI/LO valve that controls the ame height. Fan Kit models DVFFBK and DVFFBKT are available for these units as an option.
www .desatech.com 1 12108-01C 4 W ARNING: Do not allow fans .
www .desatech.com 1 12108-01C 5 DIMENSIONS FRONT VIEW 30" (Opening) 25" 19 7 / 8 " (Opening) RIGHT SIDE 1 7 / 8 " 22 5 / 8 " 41 1 / 8 " 32"(Opening) 1 7 / 8 " 3.
www .desatech.com 1 12108-01C 6 CLEARANCES Mi ni mu m cle ar an ce s to com bust ibl es for the r e - pl ac e ar e as f ol lo ws : Back and Sides of Surround* 0" V ent Surface (Side and Bottom.
www .desatech.com 1 12108-01C 7 PRE-INST ALLA TION PREP ARA TION Continued Figure 6 - Rough Opening for Fireplace 39 3 / 4 " Min. 40 1 / 2 " 24" 39 3 / 4 " Min. 40 1 / 2 " 24" * Figure 7 - Rough Opening for Installing Fireplace on Platform * As required by design as long as ceiling clearance is maintained.
www .desatech.com 1 12108-01C 8 GENERAL VEN TIN G These models are approved for use with DESA 58 Series, rigid type direct vent pipe as supplied by DESA or with approved types of exible vent pipe (not supplied) when appropriately sized for an 8" outer and 5" inner diameter application.
www .desatech.com 1 12108-01C 9 Fixed Closed Op en ab le Fixed Closed V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION CAP AIR SUPPL Y INLET GAS METER RESTRICTED AREA (TERMINA TION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony [*12" (30.
www .desatech.com 1 12108-01C 10 VENT ING INST ALLA TION INSTRUCTIONS W ARNING: Read all instruc- .
www .desatech.com 1 12108-01C 1 1 VENTING INST ALLA TION INSTRUCTIONS Continued Your DESA dire ct-v ent rep lace has been test ed for a min imum 3' rise wit h a maxim um 11" wal l thic knes s.
www .desatech.com 1 12108-01C 12 VENTING INST ALLA TION INSTRUCTIONS Continued Figu re 16 - Installing Horizontal V ent Cap (Noncombustible Exterior) Wood Screw V ent Cap Figure 17 - Installing Siding.
www .desatech.com 1 12108-01C 13 V ent Cap (Horizontal T ermination) Interior W all Surface W all Firestop Horizontal V ent Pipe Figure 18 - Connecting V ent Cap with Horizontal V ent Pipe Screw VENTING INST ALLA TION INSTRUCTIONS Continued 5.
www .desatech.com 1 12108-01C 14 VENT ING INST ALLA TION INSTRUCTIONS Continued INST ALLA TION FOR VERTICAL TERMINA TION .
www .desatech.com 1 12108-01C 15 VENT ING INST ALLA TION INSTRUCTIONS Continued 2. Assemble the desired lengths of pipe and elbows necessary to reach from the replace ue up through the restop. All connections must be sealed with high temperature silicone sealant as specied in the second warning statement on page 1 1.
www .desatech.com 1 12108-01C 16 V ertical Horizontal (V 1 ) (H) 5' min. 6' max. 6' min. 12' max. 7' min. 18' max. 8' min. 20' max.
www .desatech.com 1 12108-01C 17 VENT ING INST ALLA TION INSTRUCTIONS Continued Figure 29 - V ertical Rigid V enting Conguration With No Horizontal Run V = 40' max.
www .desatech.com 1 12108-01C 18 E58-45 45° Elbow, Galvanized E58-90 90° Elbow, Galvanized FSE58-45 45° Starter Elbow (Dura V ent to FMI Pipe) F.
www .desatech.com 1 12108-01C 19 INST ALLA TION Continued Figure 33 - Removing Louver Glass Locating Holes Spring Latch Recommended Blower Speed Control Location .
www .desatech.com 1 12108-01C 20 INST ALLA TION Continued 1.
www .desatech.com 1 12108-01C 21 INST ALLA TION Continued IMPORT ANT : The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig.
www .desatech.com 1 12108-01C 22 INST ALLA TION Continued O F F P I L O T O N L O H I P I L O T E A 16AI 7 TPTH TP TH Figure 41 - Millivolt Control V alve Pilot Adjustment Cap ON/OFF Knob Outlet Press.
www .desatech.com 1 12108-01C 23 8. Take twigs “C” (shaped like a “Y”) and place them as shown in Figure 48. 9. Take twigs “D” (bent twig) and place them as shown in Figure 48 . 10. Place twi g “E” acro ss the top of logs “B ” as show n in Fig ure 48.
www .desatech.com 1 12108-01C 24 1/2" (12.7 mm) 3/4" (19 mm) Edge of Burner T op of Burner Figure 50 - Correct Ignitor Location (Side V iew) b URNER FLAME ADjUSTMENT The air shutter, located.
www .desatech.com 1 12108-01C 25 5 . T o reinstall burner, follow reverse steps ma kin g su re a ir sh ut ter on b urn er tu be i s completely seated over orice mount.
www .desatech.com 1 12108-01C 26 3. If replacement is necessary , the entire assem- bly (fra me and glass) mus t be repla ced . If glas s is br oken, wear g loves and tape remain ing fragments onto the frame. Remove 5 screws located on end of rebox while holding frame assembly to prevent it from falling and caus- ing injury (see Figure 54).
www .desatech.com 1 12108-01C 27 O F F P I L O T O N L O H I P I L O T E A 16AI 7 TPTH TP TH Gas Control Knob Flame Adjustment Knob Position Indicator Figure 56 - Millivolt Control V alve Figure 57 - Pilot Thermopile Pilot Burner Piezo Ignitor Thermocouple 6.
www .desatech.com 1 12108-01C 28 5. Smell for gas, including near the oor . If you smell gas, STOP! Follow “B” in the safety information, page 27. If you don’t smell gas, go to the next step. 6. T urn main burner wall switch to the ON position for ignition.
www .desatech.com 1 12108-01C 29 TROUbLESHOO TING .
www .desatech.com 1 12108-01C 30 REMEDY 1. Replace ignitor if wire is prop- erly connected and you have no spark 2. Us in g a ma tc h, li ght pi lot . If pi- lo t lig ht s tur n off pi lot a nd pu sh pie zo aga in.
www .desatech.com 1 12108-01C 31 TROUbLESHOO TING Continued REMEDY 1. Check ignition wire connec- tion (see W iring Diagrams) 2. Ch eck gr oun d wi re con ne ct ion (s ee W ir in g Di ag r am s) 3. Clean and adjust main burner; c he c k g a s s u pp l y an d i n le t pressure; replace ignition as- sembly if necessary 1.
www .desatech.com 1 12108-01C 32 P ARTS AND ACCESSORIES MANUAL GAS CONTROL V AL VE Contact a qualied technician if replacement is required.
www .desatech.com 1 12108-01C 33 Fo r a ll m od el s.
www .desatech.com 1 12108-01C 34 G N D V2 L1 IND TS S1 P . SW V1 FENWAL AUTOMA TIC IGNITION SYSTEM .
www .desatech.com 1 12108-01C 35 _____________________________________________________ ______________________________________________________ ______________________________________________________ ___.
2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com NOT A UPC 1 12108-01 Rev . C 03/06 WARRANTy INFORMA TION KEEP THIS WARRANTy Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory .
An important point after buying a device Desa DVF36CR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Desa DVF36CR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Desa DVF36CR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Desa DVF36CR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP you will learn all the available features of the product, as well as information on its operation. The information that you get Desa DVF36CR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP will certainly help you make a decision on the purchase.
If you already are a holder of Desa DVF36CR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Desa DVF36CR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP.
However, one of the most important roles played by the user manual is to help in solving problems with Desa DVF36CR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Desa DVF36CR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center