UNVENTED (VENT-FREE)

UNIVERSAL FIREBOX

OWNER’S OPERATION AND INSTALLATION MANUAL

CGFB32C Circulating

Louvered

Model

hearth base.

— Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a

This firebox has been tested and approved by I.A.S. under their REQ. 2-97 for use with any ANS Z21.11.2 approved gas logs.

qualified installer, service agency, or the gas supplier.

This firebox may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer (i.e. Installation of this product is permitted after the manufactured (mobile) home is sited).

Save this manual for future reference.

Show 169 more labels / short text on this page
· · · · · · · · · · · · · · · ® · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Shown with optional · · · · · · · · · · · · · · · · · · · · · · · · · · · cabinet mantel and · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · ·
Page 2 of the Desa CGFB32C user manual — UNPACKING
Page 2 · click to enlarge
Page 2

SAFETY INFORMATION

  • 5. You must operate this fireplace with the provided fireplace screen (closed), hood, and brick liner in place. Make sure these parts are in place before running firebox. 6. Do not allow fans to blow directly into the firebox. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting. 7. Do not use a blower insert, hood, heat exchanger insert, or other accessory not approved for use with this heater. 8. Vent-free gas log heaters installed in these fireboxes require fresh air ventilation to run properly. See Air for Combustion and Ventilation , pages 4 through 6. 9. Do not run firebox
  • where flammable liquids or vapors are used or stored
  • under dusty conditions 10. Do not use this firebox to cook food or burn paper or other objects. 11. Never place any objects in the firebox or on logs. 12. Firebox front and screen becomes very hot when running firebox. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Firebox will remain hot for a time after shutdown. Allow surfaces to cool before touching. 13. Carefully supervise young children when they are in the room with firebox. 14. Turn firebox off and let cool before servicing. Only a qualified service person should service and repair firebox. 15. Operating unvented heaters (logsets) above elevations of 4,500 feet could cause pilot outage. 16. Do not use the firebox if it has been under water due to the shock hazard that could result with the blower accessary (if installed) in place.

LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223.1, also known as NFPA 54*. Firebox must be electrically grounded in accordance with the National Electrical Code, ANS/NFPA70 (latest edition).

WARNINGS

*Available from:

American National Standards Institute, Inc.

1430 Broadway New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park Quincy, MA 02269

UNPACKING

  • 1. With utility knife, cut the carton all the way around above the staples on the bottom tray. Lift the carton off the firebox. Remove packing. 2. Check carton contents for the following:
  • Screen assembly
  • Screen support rod
  • Hardware and parts bag containing the following:
  • Owner’s Operation and Installation Manual
  • 2 - Black #10 x 5/8" shouldered hex screws 3. If any items are missing, inform dealer where you bought firebox. 4. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought firebox.
  • 1. This firebox shall not be installed in a bedroom or bathroom. 2. Never install the firebox
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the firebox
  • in high traffic areas
  • in windy or drafty areas 3. Do not use this firebox as a wood-burning fireplace. 4. Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting.

2 103573

Page 3 of the Desa CGFB32C user manual — BLOWER ACCESSORY
Page 3 · click to enlarge
Page 3

PRODUCT FEATURES

PRODUCT SPECIFICATIONS

OPERATION

35 1/16"

This firebox is designed to accept unvented decorative gas logs. It requires no outside venting or chimney making installation easy and inexpensive. When used without the blower the firebox requires no electricity making it ideal for emergency backup heat.

2 3/4"

BLOWER ACCESSORY

The CGFB32C firebox will accept the GA3750 accessory. The variable blower allows you to select the fan speed you de- sire. The blower circulates heated air from the firebox into the room. Use of blower is optional.

19 3/8" Built-in Nailing Flanges

16 1/4"

31 3/4"

2 3/4"

6 3/8"

Figure 1 - Firebox Front View

2 1/4"

22 1/2"

33 11/16"

32 3/16"

16 11/16" 13 1/4"* 14 1/4"*

19 1/4"

12 1/2"

9 3/4"

4 5/8"

31 5/8" 34 3/8" 35 5/8"

2 1/2"

Electrical Access Hole Gas Line Access

*Note: 14 1/4" is total firebox cavity depth including brick liner. 13 1/4" is depth of flat floor including brick liner.

Figure 2 - Firebox Side View

Figure 3 - Firebox Top View

6" · Electrical Access Hole · 3 103573

Page 4 of the Desa CGFB32C user manual — AIR FOR COMBUSTION AND VENTILATION
Page 4 · click to enlarge
Page 4

LOCATING FIREBOX

PROVIDING ADEQUATE VENTILATION

Confined and Unconfined Space

The National Fuel Gas Code (ANS Z2123.1, 1992 Section 5.3) defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.

The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation.

PLANNING

Plan where you will install the firebox. This will save time and money later when you install the firebox. Before installation, con- sider the following: 1. Where the firebox will be located. Al- low for wall and ceiling clearances (see Installation Clearances, page 7). 2. Everything needed to complete instal- lation. 3. These models CANNOT be installed in a bedroom or bathroom. 4. Proper air for combustion and ventila- tion (see below).

All spaces in homes fall into one of the three following ventilation classifications:

1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space

The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

This firebox shall not be installed in a con- fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.

AIR FOR COMBUSTION AND VENTILATION

* Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.

Unusually tight construction is de- fined as construction where: a. walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6x10-11 kg per pa-sec-m2) or less with open- ings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, be- tween wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings.

Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 6.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.

If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow For Fireplace Location, page 5.

Exhaust fans, fireboxes, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.

4 103573

Page 5 of the Desa CGFB32C user manual — Determining if You Have a Confined or Unconfined Space
Page 5 · click to enlarge
Page 5

AIR FOR COMBUSTION AND VENTILATION Continued

DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION

Determining if You Have a Confined or Unconfined Space

Use this worksheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install firebox plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = cu. ft. (volume of space) Example: Space size 22 ft. (length) x 18 ft. (width) x 8 ft. (ceiling height) = 3168 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

(volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support) Example: 3168 cu. ft. (volume of space) ÷ 50 cu. ft. = 63.3 or 63,300 (maximum Btu/Hr the space can support) 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free firebox Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas firebox logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

Example: Gas water heater 40,000 Btu/Hr Vent-free firebox with log heater + 39,000 Btu/Hr Total = 79,000 Btu/Hr

Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used) Example:63,300 Btu/Hr (maximum the space can support)

79,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6. C. Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

Continued · 5 103573

Page 6 of the Desa CGFB32C user manual — Ventilation Air From Outdoors
Page 6 · click to enlarge
Page 6

12" AIR FOR COMBUSTION AND VENTILATION Continued

Ventilation Grills Into Adjoining Room,

VENTILATION AIR

Or Remove Door into Adjoining

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 4). You can also remove door into adjoining room (see op- tion 3, Figure 4). Follow the National Fuel Gas Code NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Figure 4 - Ventilation Air from Inside Building

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.

Inlet Air Ventilated Crawl Space

Figure 5 - Ventilation Air from Outdoors

Show 99 more labels / short text on this page
Ventilation · Grills Into Adjoining · Option 2 · Room, Option 1 · Room, Option · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 12" · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Ventilated Attic · Outlet Air · Outlet Air · To Attic · To Crawl Space · · · · · · · Inlet Air · · · · 6 103573
Page 7 of the Desa CGFB32C user manual — Mantel Clearances for Built-In Installation
Page 7 · click to enlarge
Page 7

Note: Your Comfort Glow firebox is de- signed to be used in zero clearance installa- tions. Wall or framing material can be placed directly against any exterior surface on the rear, sides, or top of your firebox, except where standoff spacers are integrally at- tached. If standoff spacers are attached to your firebox, these spacers can be placed directly against wall or framing materials. Use the dimensions shown for rough open- ings to create the easiest installation (see Built-In Firebox Installation, page 10).

Mantel Clearances for Conventional Installation

INSTALLATION

NOTICE: This firebox in combi- nation with unvented logsets are intended for use as supplemen- tal heat. Do not install them as your primary heat source. If you have a central heating system, you may run system’s circulat- ing blower while using unvented logs. This will help circulate the heat throughout the house. In the event of a power outage, you can use unvented logs as your pri- mary heat source.

MINIMUM CLEARANCE Side Wall - 16 " Ceiling - 42" Floor - 0"

16" Face or Cabinet

INSTALLATION CLEARANCES

Figure 6 - Minimum Clearance to Wall and Ceiling

Mantel Clearances for Built-In Installation

  • WARNING: Never install the firebox
  • in a bedroom or bathroom
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the firebox
  • in high traffic areas
  • in windy or drafty areas

Carefully follow the instructions below. This will ensure safe installation.

If placing custom mantel above built-in firebox, you must meet minimum clearance between mantel shelf and top of firebox opening.

Minimum Wall and Ceiling Clearances (see Figure 6) A. Clearances from the side of the fire- box opening to any combustible wall should not be less than 16 inches for a cabinet mantel or 12 inches for a cor- ner installation. B. Clearances from the top of the firebox opening to the ceiling should not be less than 42 inches. C. When the firebox is installed directly on carpeting, or other combustible ma- terial, other than wood flooring, the firebox should be installed on a metal or wood panel extending the full width and depth of the enclosure.

Facing material (above firebox) may be of combustible material, including decorative mantel ornaments.

2 1/2"

For CGFB32C Series circulating louvered models only

13" 16" 19" 21"

Supplied Firebox Hood Must Be Used at All Times

Figure 7 - Minimum Mantel Clearances for Built-In Installation

  • If your installation does not meet the above minimum clearances, you must:
  • raise the mantel to an acceptable height, OR
  • remove the mantel.
Show 19 more labels / short text on this page
42" · · Mantel · · · · 12" · · · Corner Mantel · Floor - 0" · Mantel Shelf · 10" · 8" · 6" · Firebox · Wire-mesh Screen · Continued · 7 103573
Page 8 of the Desa CGFB32C user manual — INSTALLING BLOWER ACCESSORY
Page 8 · click to enlarge
Page 8

Built-In Installation of Blower Accessory 1. Install blower assembly per instruction sheet included. 2. Before replacing bottom of firebox, remove screw holding duplex outlet to the support bracket in the bottom of firebox. Remove duplex outlet. 3. Clamp electrical cable into firebox through smallest hole using strain re- lief provided. 4. Route wires from electrical box through hole in side of heater and hole in sup- port bracket (see Figure 9). 5. Connect wires from the electrical box to duplex outlet. Match wire colors to those indicated on duplex outlet. Be sure to connect ground wire. 6. Replace duplex outlet with screw. 7. Plug blower power cord into duplex outlet. 8. Replace bottom of firebox.

INSTALLING LOG HEATER IN FIREBOX

INSTALLATION Continued

INSTALLING BLOWER ACCESSORY

You may install blower accessory GA3750 with conventional installation (below) or with built-in installation (page 10). To install blower accessory, see instruction sheet in- cluded with the kit.

Conventional Installation of Blower Accessory 1. Install blower assembly per instruction sheet included in blower accessory kit. 2. Before replacing bottom of firebox, route blower power cord through hole in support bracket in bottom of firebox and through hole in side of firebox to grounded, three-prong 120 volt electri- cal outlet (see Figure 8). Plug electri- cal cord into outlet. 3. Replace bottom of firebox.

1. Remove four screws holding firebox bottom in place. 2. Lift and remove firebox bottom (see Figure 10). 3. If installing GA3750 blower accessory, see Installing Blower Accessory . 4. Route flexible gas line from manual shutoff valve into firebox through side.
Desa CGFB32C — INSTALLING BLOWER ACCESSORY diagram (page 8)
Fig. 1
5. Attach gas log heater base to firebox bottom with four screws included with base (see Installing Heater Base Assembly in log set owner’s manual). 6. Replace firebox bottom and secure with screws.
Desa CGFB32C — INSTALLING BLOWER ACCESSORY diagram (page 8)
Fig. 2
Desa CGFB32C — INSTALLING BLOWER ACCESSORY diagram (page 8)
Fig. 3

Figure 9 - Routing Blower Accessory Power Cord for Built-In Installation

Figure 10 - Removing Firebox Bottom

Figure 8 - Routing Blower Accessory Power Cord for Conventional Installation

Cord · Cord · 8 103573

Page 9 of the Desa CGFB32C user manual — FIREBOX INSTALLATION USING OPTIONAL ACCESSORY MANTELS
Page 9 · click to enlarge
Page 9

INSTALLATION Continued

1. Assemble cabinet mantel, hearth base, and perimeter trim (Included with man- tel). Assembly instructions are included with each accessory. 2. If using an optional GA3750 blower, install a properly grounded, 120 volt three-prong electrical outlet at firebox location if an outlet is not there. If pos- sible, locate outlet so cabinet mantel will cover it when installed (see Figure 13). 3. Install gas piping to firebox location. This installation includes an approved flex- ible gas line (if allowed by local codes) and a manual shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Connecting to Gas Supply in your log set owner’s manual.

9. Attach flexible gas line to log set. See Connecting to Gas Supply in your log set owner’s manual. 10. If installing GA3750 blower, route blower electrical cord through bushing in right side firebox support and bush- ing in side access opening of firebox. Plug electrical cord into electrical out- let. See Installing Blower Accessory, page 8. 11. Carefully insert firebox into cabinet man- tel. Be careful not to scratch or damage cabinet mantel or hearth base. Remove protective material from top of hearth base and from front of firebox (if any). 12. Install the trim after final finishing and/ or painting of wall. See instructions in- cluded with mantel accessory for at- taching brass trim. 13. Check all gas connections for leaks. See Checking Gas Connections in log set owner's manual.

INSTALLING FIREPLACE SCREEN 1. Insert each rod through nine rings lo- cated at top of screen. 2. Insert first rod into rear hole in left side of firebox. Fasten rod to rear hole near center of firebox using black shoulder screw. 3. Insert other rod into front hole on right side of firebox and fasten using remain- ing shoulder screw.

4. Place hearth base accessory against wall at installation location. Cut an access hole in hearth top to run flexible gas line to firebox (see Figure 12). Make sure to locate access hole so cabinet mantel will cover it when installed. Note: You can secure base to floor using wood screws. Countersink screw heads and putty over. 5. Route flexible gas line through access hole in hearth base. 6. Center cabinet mantel on hearth base (see Figure 13). Make sure mantel is flush against wall. 7. Break off nailing flanges (see Figure 14) with hammer or pliers. 8. Place cardboard or other protective material on top of hearth base. Care- fully set firebox on protective material, with back of firebox inside mantel opening.

Figure 11 - Installing Fireplace Screen

FIREBOX INSTALLATION USING OPTIONAL ACCESSORY MANTELS

Figure 13 - Installing Cabinet Mantel

This firebox may be installed using the cabi- net mantel and hearth base accessories against a wall in your home. Follow the instructions below to install the firebox in this manner.

Gas Line Access Hole

Figure 14 - Location of Nailing Flanges

Figure 12 - Placing Hearth Base Accessory Against Wall

Show 71 more labels / short text on this page
Rear Hole · Screw · Front Hole · · Rod · · · · · · · · · · · · · · · Ring · · · · · · · · · · Cabinet Mantel · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Screen · · · · · · · Nailing Flanges · Electrical Outlet · Flexible Gas Line · Hearth Base · Continued · 9 103573
Page 10 of the Desa CGFB32C user manual — Figure 15 - Inserting Firebox Into Cabinet Mantel BUILT-IN FIREBOX INSTALLATION
Page 10 · click to enlarge
Page 10

INSTALLATION Continued

1. Frame in rough opening. Use dimen- sions shown in Figure 16 for the rough opening. If installing in a corner, use dimensions shown in Figure 17 for the rough opening. The height is 33", which is the same as the wall opening in Figure 16. 2. Install gas piping to firebox location. This installation includes an approved flexible gas line (if allowed by local codes) after the manual shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Connect- ing to Gas Supply in log set owner’s manual.

3. Carefully set firebox in front of rough opening with back of firebox inside wall opening. IMPORTANT: If installing Brass Trim Kit GA7090, see instructions included with brass trim accessory. You must install shoulder screws now. 4. If using GA3750 blower accessory, see Installing Built-In Installation of Blower Accessory, page 8. 5. Attach flexible gas line to log set. See Connecting to Gas Supply in log set owner’s manual. 6. Carefully insert firebox into rough opening. 7. Attach firebox to wall studs using nails or wood screws through holes in nail- ing flange (see Figure 18). 8. Check all gas connections for leaks. See Checking Gas Connections in log set owner’s manual. 9. If using optional GA7090 brass trim kit, install the trim after final finishing and/ or painting of wall. See instructions in- cluded with brass trim accessory for at- taching brass trim.

Desa CGFB32C — INSTALLATION Continued diagram (page 10)
Fig. 4 · INSTALLATION Continued
Desa CGFB32C — INSTALLATION Continued diagram (page 10)
Fig. 5 · INSTALLATION Continued

Figure 15 - Inserting Firebox Into Cabinet Mantel BUILT-IN FIREBOX INSTALLATION

Built-in installation of this firebox involves installing firebox into a framed-in enclosure. This makes the front of firebox flush with wall. Optional brass trim (GA7090) is avail- able (see Accessories, page 11) This brass trim will extend past sides of firebox ap- proximately 1/2 inch. This will cover rough edges of the wall opening. If installing a mantel above the firebox, but you must fol- low the clearances shown in Figure 7, page 7. Follow the instructions below to install the firebox in this manner.

Desa CGFB32C — Figure 15 - Inserting Firebox Into Cabinet Mantel BUILT-IN FIREBOX INSTALLATION diagram (page 10)
Fig. 6 · Figure 15 - Inserting Firebox Into Cabinet Mantel BU…

Figure 16 - Rough Opening for Installing in Wall

39 3/8" 27 7/8"

55 5/8" 34 3/4"

Figure 17 - Rough Opening for Installing in Corner

Figure 18 - Attaching Firebox to Wall Studs

HeightFront WidthDepth Model #ActualFraming ActualFramingActualFraming CGFB32C32 3/ " 833"34 5/ " 1634 3/ " 416 11/ " 1617 3/ " 4 CGFB32NC33 11/16" 34 1/4"34 5/16"34 3/4"16 11/16"17 3/4"
Desa CGFB32C — Figure 15 - Inserting Firebox Into Cabinet Mantel BUILT-IN FIREBOX INSTALLATION diagram (page 10)
Fig. 7 · Figure 15 - Inserting Firebox Into Cabinet Mantel BU…

10 103573

Page 11 of the Desa CGFB32C user manual — PARTS NOT UNDER WARRANTY
Page 11 · click to enlarge
Page 11

TECHNICAL SERVICE

ACCESSORIES

Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-432-2382 for information. You can also write to the ad- dress listed on the back page of this manual.

You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).

You can also visit DESA International’s Technical Service web site at www.desatech.com REPLACEMENT PARTS

CABINET MANTEL WITH PERIMETER BRASS TRIM GMC11F Series - Walnut Finished GMC13F Series - Oak Finished GMC12U Series - Unfinished Mantel features moldings, fluted sides and medallion. Available in walnut finished or unfinished hardwood, ready to stain or paint. Shown with optional base accessory. Approximate Dimensions (HxWxD): 44" x 57 3/4" x 22 7/8"

MANUAL SHUTOFF VALVE GA5010 For all models. Manual shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.

PARTS UNDER WARRANTY

Contact authorized dealers of this product or Parts Central (see page 15). If they can’t supply original replacement part(s), call DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).

  • When calling DESA International, have ready
  • your name
  • your address
  • model and serial numbers of your fireplace
  • how fireplace was malfunctioning
  • type of gas used (propane/LP or natural gas)
  • purchase date

BLOWER ACCESSORY - GA3750 The variable blower allows you to select the desired speed. The blower circulates heated air from the fireplace into the room.

Usually, we will ask you to return the defec- tive part to the factory.

HEARTH BASE - Use with Cabinet Mantel GC3333F- Walnut Finished GC3335F Series - Oak Finished GC3334U - Unfinished The hearth base creates a handsome riser for the fireplace. Approximate Dimensions (HxWxD): 6 1/2" x 58" x 28 9/16"

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product or Parts Central (see page 15). If they can’t supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information.

CORNER MANTEL WITH PERIMETER BRASS TRIM GMC36F Series - Walnut Finished GMC37U Series - Unfinished Ideal for space saving installations. Approximate Dimensions (WxHxD): 60 7/8" x 48 3/4" x 34 5/8"

  • When calling DESA International, have ready
  • model number of your fireplace
  • the replacement part number

BRASS TRIM ACCESSORY GA7090 (Not Shown) Required with all mantel accessories. Op- tional with built-in installation. Provides a finished appearance covering rough and/or unfinished mantel edges.

Show 329 more labels / short text on this page
· · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 11 103573
Page 12 of the Desa CGFB32C user manual — TECHNICAL SERVICE
Page 12 · click to enlarge
Page 12
Desa CGFB32C — TECHNICAL SERVICE diagram (page 12)
Fig. 8

12 103573

Page 13 of the Desa CGFB32C user manual — CGFB32C
Page 13 · click to enlarge
Page 13

PARTS LIST FIREBOX

This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 11 of this manual.

KEY CGFB32C NO. PART NUMBER DESCRIPTION QTY.

CGFB32C

1 101872-03 Firebox Top 1 2 101889-01 Firebrick Retainer 3 3 101929-03 Rear Firebrick 1 4 101932-03 Side Firebrick 2 5 103207-01 Outer Casing 1 6 103208-01 Outer Shell Base 1 7 103245-01 Firebox Wrapper 1 8 103297-01 Assembly Screen 2 9 M12461-2 Screw, Outlet Mounting 1 10 ** Front Assembly 10-1 103773-03CK Hood, Louvered, Painted 1 10-2 103205-01CK Side, Left, Painted 1 10-3 103206-01CK Side, Right, Painted 1 10-4 M11084-26 Screw, HWH AB 10-16 8 11 103250-01CK Firebox Bottom 1 12 103809-01 Screen Rod 2 13 101348-01 Firebox Support 2 14 101357-01 Outer Casing Top 1 15 M11084-26 Hex Head Screw, #10-16 49 16 103771-01 Strain Relief Fitting 1 17 098304-01 Phillips Pan Head Screw, #10 13 18 103769-01 Duplex Outlet 1 19 099230-02 Shoulder Screw 2

**Not Available as an Assembly

PARTS CENTRALS These Parts Centrals are privately-owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.

Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Department

Four Flags Power Products 1115 Stateline Road Niles, MI 49120-4728 616-684-2697 1-800-268-4983 Parts Only

East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764-1542 732-870-8809 1-800-755-8809 Parts Department

Halco Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382-4500 610-430-7717 1-800-368-0803 Parts Department

Portable Heater Parts 342 N. County Rd. 400 E. Valparaiso, IN 46383-9704 All States 219-462-7441 1-800-362-6951 Parts Department

Master Parts Distributor 1251 Mound Ave. NW Grand Rapids , MI 49504-2672 616-791-0505 1-800-446-1446 Fax: 1-616-791-8270 Parts Department

Tarantin Tank Co. P.O. Box 6129 Freehold, NJ 07728-6129 908-780-9340 1-800-922-0724 Parts Department

Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687-0013 All States 803-879-3009 1-800-845-5301 Parts Department

Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404 All States 513-258-3721 OH 1-800-762-3426 Parts Department

FBD 1349 Adams St. Bowling Green, KY 42103-3414 270-846-1199 1-800-654-8534 Fax: 1-800-846-0090

Washer Equipment Co. 1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 Parts Department

Heater and Fireplace Store 1922 N. Route 9 Cape May Court, NJ 08210-1110 609-624-0678 Parts Department

13 103573

Page 14 of the Desa CGFB32C user manual — NOT A UPC
Page 14 · click to enlarge
Page 14

WARRANTY INFORMATION

KEEP THIS WARRANTY

Serial No

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY COMFORT GLOW VENT-FREE RESIDENTIAL GAS HEATERS

DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA- TION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

INTERNATIONAL

2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com

NOT A UPC

103573-01 Rev. G 10/99

Model Date Purchased 103573 01

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
GC3333FWalnut Finished p.11
GC3334UUnfinished p.11

Ask about the Desa CGFB32C

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Desa CGFB32C

Be the first to ask — other owners or our team will answer.

Original document

Desa CGFB32C manual PDF

14 pages·532 KB·Outdoor Fireplace·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…