For more information, visit www .desatech.com DIRECT -VENT FIREPLACE OWNER’S OPERA TION AND INST ALLA TION MANU AL NA TURAL GAS “TUDOR” MODELS (V)T32N SERIES AND CHD V32NR PROP ANE/LP GAS “TUD.
www .desatech.com 1 1 1986-01D 2 SAFETy INFORMA TION T AbLE OF CONTENTS Safety Information ............................................... 2 Local Codes......................................................... 4 Product Identication ...............
www .desatech.com 1 1 1986-01D 3 SAFETy INFORMA TION Continued This replace must be installed by a qualied (cer - tied or licensed) service person. It has a sealed gas combustion chamber that uses a coaxial pipe (pipe within a pipe and having the same center) venting system.
www .desatech.com 1 1 1986-01D 4 SAFETy INFORMA TION Continued 2. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch any electrica l switch; do not use any phone in your building • immediately call your gas supplier from a neighbor ’ s phone.
www .desatech.com 1 1 1986-01D 5 Figure 2 - Common Fireplace Locations Flush with a wall Through exterior wall enclosed in a chase Corner installation • This replace does not require electricity to operate.
www .desatech.com 1 1 1986-01D 6 PRE-INST ALLA TION PREP ARA TION Continued Figure 4 - Framing Clearances for Installation Against an Exterior Wall Figure 5 - Framing Clearances for Corner Installation C B A D E F G T op of Louver Opening 3 2 1 4 5 6 7 Wall Ref.
www .desatech.com 1 1 1986-01D 7 Figure 7 - Minimum Clearances for T ermination Cap LOCA TION OF TERMINA TION CAP Fixed Closed Op en ab le Fixed Closed V V V V V V V V X X V X G G J F B B K N H I A N .
www .desatech.com 1 1 1986-01D 8 VENT ING INST ALLA TION INSTRUCTIONS NOTICE: Read these instruc- .
www .desatech.com 1 1 1986-01D 9 INST ALLA TION PLANNING There are two basic types of direct-vent in - stallation: • Horizontal T ermination • V ertical T ermination Horizontal T ermination Installation IMPORTANT : Horizontal square terminations require only inner portion of wall restop.
www .desatech.com 1 1 1986-01D 10 VENTING INST ALLA TION INSTRUCTIONS Continued W ARNING: Do not recess 6.
www .desatech.com 1 1 1986-01D 1 1 VENTING INST ALLA TION INSTRUCTIONS Continued Figure 13 - T ypical Horizontal T ermination Cap Mounting with Additional Siding Standoff Installed Siding Standoff Scr.
www .desatech.com 1 1 1986-01D 12 CORN ER AND AL TERNA TE INST ALL A TIO N Recommended Applications: • Corner ground oor installation • G ro un d o or in st a l la ti on w he re pi p e v en.
www .desatech.com 1 1 1986-01D 13 VENTING INST ALLA TION INSTRUCTIONS Continued Horizontal (H 1 Horizontal (H 1 Horizontal (H 2 5' min.
www .desatech.com 1 1 1986-01D 14 INST ALLA TION FOR VERTICAL TERMINA TION Note: V ertical restrictor must be installed in all vertical installations. 1.
www .desatech.com 1 1 1986-01D 15 5. Pla ce the ash in g o ver t he pi pe sec tio n( s) extendin g through the roof. Secure the base of the ashing to the roof and framing with roof - ing nails. Be sure roong materi al overlap s the top edge of the ashing as shown in Figure 19, page 14.
www .desatech.com 1 1 1986-01D 16 VENTING INST ALLA TION INSTRUCTIONS Continued Note : Install restrictor into inner collar of replace as shown. V ertical (V 1 5' min.
www .desatech.com 1 1 1986-01D 17 AND COMPONENTS .
www .desatech.com 1 1 1986-01D 18 FIREPLACE INST ALLA TION Use proper gas type for replace unit you are installing.
www .desatech.com 1 1 1986-01D 19 FIREPLACE INST ALLA TION Continued Figure 27 - Location of Wiring Diagram Decal (Model May V ary from Illustration) Wiring Diagram Decal 12" in Front of Burner 9. Check to make sure power cord is completely clear of blower wheel and there are no other foreign objects in blower wheel.
www .desatech.com 1 1 1986-01D 20 1 1. Peel off backing paper and stick supplied wiring diagram decal on rebox bottom ap - proxima tely 12" in front of blower (see Figure 27, page 19).
www .desatech.com 1 1 1986-01D 21 FIREPLACE INST ALLA TION Continued Figure 31 - Gas Connection CSA Design-Certied Equipment Shutoff V alve with 1/8" NPT T ap* 3" Minimum Approved Flexible Gas Line Cap Pipe Nipple T ee Joint Sediment T rap/Drip Leg Natural - From Gas Meter (5.
www .desatech.com 1 1 1986-01D 22 PRESSURE TESTING GAS SUPPL Y PIPING SYSTEM T est Pressures In Excess Of 1/2 PSIG 1. Dis conne ct rep lac e and i ts indiv idual equ ip - ment shutoff valve from gas supply piping sy st em .
www .desatech.com 1 1 1986-01D 23 INST ALLING OPTIONAL W ALL MOUNT SWITCH - GWMS2 1. Connect one terminal of 25 ft. wire for wall switch to TPTH terminal on the valve. Con - nect remaining wire terminal to the TH termi - nal on the valve. Make sure wire terminals are in positions on unit as pictured in Figure 36.
www .desatech.com 1 1 1986-01D 24 REMOVING/REPLACING GLASS DOOR .
www .desatech.com 1 1 1986-01D 25 .
www .desatech.com 1 1 1986-01D 26 6. Place log #6 (left log) onto two pins on left side of back and front log. See Figure 48. 7. Pla ce lava rock alon g sid es and front of rebox bottom in areas that are visible only . It is not necessary to use all of lava rock provided.
www .desatech.com 1 1 1986-01D 27 5. W ait ve (5) minutes to clear out any gas. Then smell for gas, including near the oor . Ifyousmell gas,STOP!Follow“B” inthe safe ty info rmati on in column 1.
www .desatech.com 1 1 1986-01D 28 OPERA TING FIREPLACE Continued MANUAL LIGHTING PROCEDURE 1. Rem ove gla ss doo r (se e Remo vin g/R epl aci ng Glass Door ,page24.) 2. Follow steps 1 through 7 under Lighting Instructions, page27 .
www .desatech.com 1 1 1986-01D 29 Note : Do not leave the hand -hel dr emote int he AUT Omodeclo seto ther eplace .Th eradi ant hea t fro m the re pl ace wil l turn off the r epl ace .
www .desatech.com 1 1 1986-01D 30 INSPECTING b URNERS Check pilot ame pattern and burner ame pat - terns often. The pilot assembly is factory preset for the proper ame height. Alterations may have occurred dur - ing shipping and handling.
www .desatech.com 1 1 1986-01D 31 - .
www .desatech.com 1 1 1986-01D 32 TROUbLESHOO TING .
www .desatech.com 1 1 1986-01D 33 Pilot lights but ame goes out when control knob is released Burner does not light after pilot is lit Delayed ignition burner Burner backring during com - bustion Slight smoke or odor during initi al operation 1.
www .desatech.com 1 1 1986-01D 34 Heater produces a whistling noise when burner is lit Glass soots Fire plac e produc es a cl icki ng/t ick - ing noise just after burners are lit or shut off Remote does not function Fireplace shuts off in use 1.
www .desatech.com 1 1 1986-01D 35 TROUbLESHOO TING Continued .
www .desatech.com 1 1 1986-01D 36 REPLACEMENT P ARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty .
www .desatech.com 1 1 1986-01D 37 RLD32 - Rolled Louver , Black .
www .desatech.com 1 1 1986-01D 38 ILL USTRA TED P ARTS bREAkDOWN .
www .desatech.com 1 1 1986-01D 39 P ARTS LIST .
2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com NOT A UPC 1 1 1986-01 Rev . D 03/06 WARRANTy INFORMA TION kEEP THIS WARRANTy Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory .
An important point after buying a device Desa (V)T32N SERIES (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Desa (V)T32N SERIES yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Desa (V)T32N SERIES - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Desa (V)T32N SERIES you will learn all the available features of the product, as well as information on its operation. The information that you get Desa (V)T32N SERIES will certainly help you make a decision on the purchase.
If you already are a holder of Desa (V)T32N SERIES, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Desa (V)T32N SERIES.
However, one of the most important roles played by the user manual is to help in solving problems with Desa (V)T32N SERIES. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Desa (V)T32N SERIES along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center