EN
Dell logo
Official user manual

Dell PowerVault MD3800f

34 pages·1.2 MB·Outdoor Storage·PDF·ENDEFRITNLJA
Dell PowerVault MD3800f
Table of Contents 68 sections Dell PowerVault MD3800f and MD3820f Series Storage Arrays Deployment Guide · Introduction · System Requirements · Management Station Requirements · … ShowHide
Dell PowerVault MD3800f and MD3820f Series Storage Arrays Deployment Guidep.3Introductionp.5System Requirementsp.5Management Station Requirementsp.5Introduction to Storage Arraysp.5Related Documentationp.6Contacting Dellp.7Locating your system Service Tagp.7Hardware Installationp.8Planning The Storage Configurationp.8Connecting The Storage Arrayp.8Configuring Fibre Channel With Dell MD Series Storage Arraysp.9Configuring Fibre Channel On SAN Attached Storage Arraysp.9Configuring Fibre Channelp.9Other Information You May Needp.10Installing Supported Fibre Channel HBAsp.10Installing Fibre Channel HBA On Your Host Serverp.10Using Fibre Channel Switch Zoningp.10World Wide Name Zoningp.11Switch Zoning Guidelinesp.12Setting Up Zoning On The Fibre Channel Switch Hardwarep.12Cabling The Storage Arrayp.12Redundant And Non-Redundant Cablingp.12SAN-Attached Cablingp.13SAN-Attached Cabling Examplep.13Remote Replication Cabling Examplep.15Mixed Environmentp.17Cabling PowerVault MD1200 Series Expansion Enclosuresp.18Expanding With Previously Configured PowerVault MD1200 Series Expansion Enclosuresp.18Expanding With New PowerVault MD1200 Series Expansion Enclosuresp.19Installing PowerVault MD Storage Softwarep.21Installing Host Bus Adapters and Driversp.22Graphical Installation (Recommended)p.22Console Installationp.23Silent Installationp.23Silent Installation On Windows Systemsp.23Silent Installation On Linux Systemsp.23Enabling Premium Features (Optional)p.23Upgrading MD Storage Softwarep.24Post Installation Tasksp.25Verifying Storage Array Discoveryp.25Initial Setup Tasksp.26Uninstalling MD Storage Softwarep.27Uninstalling MD Storage Software From Windowsp.27Uninstalling MD Storage Software From Windows Server GUI Versionsp.27Uninstalling MD Storage Software From Windows Server Core Versionsp.27Uninstalling MD Storage Software From Linuxp.27Load Balancingp.28Load Balance Policyp.28Round Robin With Subsetp.28Least Queue Depthp.28Least Path Weightp.28Changing Load Balance Policies On The Windows Server Operating Systemp.29Setting Load Balance Policies in Linuxp.29Setting Load Balance Policies in VMwarep.29Working With SFP+ Modules and Fiber Optic Cablesp.30Guidelines for Using SFP+ Modulesp.30Removing SFP+ Modulesp.30Installing SFP+ Modulesp.31Guidelines for Using Fiber Optic Cablesp.31Removing Fibre Channel Cablesp.31Installing Fibre Channel Cablesp.31Hardware Cabling Best Practicesp.33Handling Static-Sensitive Componentsp.33Host Cabling for Remote Replicationp.33Cabling for Performancep.33Single-Controller and Dual-Controller Topologiesp.34Labeling Cablesp.34
Page 1 of the Dell PowerVault MD3800f user manual — Dell PowerVault MD3800f and MD3820f Series Storage Arrays Deployment Guide
Page 1 · click to enlarge
Page 1

Dell PowerVault MD3800f and MD3820f Series Storage Arrays Deployment Guide

Page 2 of the Dell PowerVault MD3800f user manual — Notes, Cautions, and Warnings
Page 2 · click to enlarge
Page 2

Notes, Cautions, and Warnings

Copyright © 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.

Rev. A01

2015 - 02

Page 3 of the Dell PowerVault MD3800f user manual — Table of contents
Page 3 · click to enlarge
Page 3

Table of contents

Dell PowerVault MD3800f and MD3820f Series Storage Arrays Deployment Guidep.3Introductionp.5System Requirementsp.5Management Station Requirementsp.5Introduction to Storage Arraysp.5Related Documentationp.6Contacting Dellp.7Locating your system Service Tagp.7Hardware Installationp.8Planning The Storage Configurationp.8Connecting The Storage Arrayp.8Configuring Fibre Channel With Dell MD Series Storage Arraysp.9Configuring Fibre Channel On SAN Attached Storage Arraysp.9Configuring Fibre Channelp.9Other Information You May Needp.10Installing Supported Fibre Channel HBAsp.10Installing Fibre Channel HBA On Your Host Serverp.10Using Fibre Channel Switch Zoningp.10World Wide Name Zoningp.11Switch Zoning Guidelinesp.12Setting Up Zoning On The Fibre Channel Switch Hardwarep.12Cabling The Storage Arrayp.12Redundant And Non-Redundant Cablingp.12SAN-Attached Cablingp.13SAN-Attached Cabling Examplep.13Remote Replication Cabling Examplep.15Mixed Environmentp.17Cabling PowerVault MD1200 Series Expansion Enclosuresp.18Expanding With Previously Configured PowerVault MD1200 Series Expansion Enclosuresp.18Expanding With New PowerVault MD1200 Series Expansion Enclosuresp.19Installing PowerVault MD Storage Softwarep.21Installing Host Bus Adapters and Driversp.22Graphical Installation (Recommended)p.22Console Installationp.23Silent Installationp.23Silent Installation On Windows Systemsp.23Silent Installation On Linux Systemsp.23Enabling Premium Features (Optional)p.23Upgrading MD Storage Softwarep.24Post Installation Tasksp.25Verifying Storage Array Discoveryp.25Initial Setup Tasksp.26Uninstalling MD Storage Softwarep.27Uninstalling MD Storage Software From Windowsp.27Uninstalling MD Storage Software From Windows Server GUI Versionsp.27Uninstalling MD Storage Software From Windows Server Core Versionsp.27Uninstalling MD Storage Software From Linuxp.27Load Balancingp.28Load Balance Policyp.28Round Robin With Subsetp.28Least Queue Depthp.28Least Path Weightp.28Changing Load Balance Policies On The Windows Server Operating Systemp.29Setting Load Balance Policies in Linuxp.29Setting Load Balance Policies in VMwarep.29Working With SFP+ Modules and Fiber Optic Cablesp.30Guidelines for Using SFP+ Modulesp.30Removing SFP+ Modulesp.30Installing SFP+ Modulesp.31Guidelines for Using Fiber Optic Cablesp.31Removing Fibre Channel Cablesp.31Installing Fibre Channel Cablesp.31Hardware Cabling Best Practicesp.33Handling Static-Sensitive Componentsp.33Host Cabling for Remote Replicationp.33Cabling for Performancep.33Single-Controller and Dual-Controller Topologiesp.34Labeling Cablesp.34
Page 4 of the Dell PowerVault MD3800f user manual — Table of contents
Page 4 · click to enlarge
Page 4

Table of contents

Dell PowerVault MD3800f and MD3820f Series Storage Arrays Deployment Guidep.3Introductionp.5System Requirementsp.5Management Station Requirementsp.5Introduction to Storage Arraysp.5Related Documentationp.6Contacting Dellp.7Locating your system Service Tagp.7Hardware Installationp.8Planning The Storage Configurationp.8Connecting The Storage Arrayp.8Configuring Fibre Channel With Dell MD Series Storage Arraysp.9Configuring Fibre Channel On SAN Attached Storage Arraysp.9Configuring Fibre Channelp.9Other Information You May Needp.10Installing Supported Fibre Channel HBAsp.10Installing Fibre Channel HBA On Your Host Serverp.10Using Fibre Channel Switch Zoningp.10World Wide Name Zoningp.11Switch Zoning Guidelinesp.12Setting Up Zoning On The Fibre Channel Switch Hardwarep.12Cabling The Storage Arrayp.12Redundant And Non-Redundant Cablingp.12SAN-Attached Cablingp.13SAN-Attached Cabling Examplep.13Remote Replication Cabling Examplep.15Mixed Environmentp.17Cabling PowerVault MD1200 Series Expansion Enclosuresp.18Expanding With Previously Configured PowerVault MD1200 Series Expansion Enclosuresp.18Expanding With New PowerVault MD1200 Series Expansion Enclosuresp.19Installing PowerVault MD Storage Softwarep.21Installing Host Bus Adapters and Driversp.22Graphical Installation (Recommended)p.22Console Installationp.23Silent Installationp.23Silent Installation On Windows Systemsp.23Silent Installation On Linux Systemsp.23Enabling Premium Features (Optional)p.23Upgrading MD Storage Softwarep.24Post Installation Tasksp.25Verifying Storage Array Discoveryp.25Initial Setup Tasksp.26Uninstalling MD Storage Softwarep.27Uninstalling MD Storage Software From Windowsp.27Uninstalling MD Storage Software From Windows Server GUI Versionsp.27Uninstalling MD Storage Software From Windows Server Core Versionsp.27Uninstalling MD Storage Software From Linuxp.27Load Balancingp.28Load Balance Policyp.28Round Robin With Subsetp.28Least Queue Depthp.28Least Path Weightp.28Changing Load Balance Policies On The Windows Server Operating Systemp.29Setting Load Balance Policies in Linuxp.29Setting Load Balance Policies in VMwarep.29Working With SFP+ Modules and Fiber Optic Cablesp.30Guidelines for Using SFP+ Modulesp.30Removing SFP+ Modulesp.30Installing SFP+ Modulesp.31Guidelines for Using Fiber Optic Cablesp.31Removing Fibre Channel Cablesp.31Installing Fibre Channel Cablesp.31Hardware Cabling Best Practicesp.33Handling Static-Sensitive Componentsp.33Host Cabling for Remote Replicationp.33Cabling for Performancep.33Single-Controller and Dual-Controller Topologiesp.34Labeling Cablesp.34
Page 5 of the Dell PowerVault MD3800f user manual — Introduction to Storage Arrays
Page 5 · click to enlarge
Page 5

1 Introduction

This document provides information about deploying Dell PowerVault MD3800f and MD3820f Fibre Channel storage arrays. The deployment process includes:

  • Hardware installation
  • Modular Disk Storage Manager (MDSM) software installation
  • Initial system configuration

Other information includes system requirements, storage array organization, and utilities.

MDSM enables an administrator to configure and monitor storage arrays for optimum usability. The version of MDSM included on the PowerVault MD series resource media can be used to manage both the Dell PowerVault PowerVault MD3800f and MD3820f systems and the earlier PowerVault MD series storage arrays. MDSM is compatible with both Microsoft Windows and Linux operating systems.

System Requirements

Before installing and configuring the PowerVault MD3800f and MD3820f series hardware and software, ensure that the minimum system requirements are met, and the supported operating system is installed. For more information, see the Dell PowerVault MD34/38 Series Support Matrix at dell.com/support/ manuals.

Management Station Requirements

A management station uses MDSM to configure and manage storage arrays across the network. For management station requirements, see Dell PowerVault MD34xx/38xx Series Support Matrix at dell.com/ support/manuals.

Introduction to Storage Arrays

A storage array includes various hardware components, such as physical disks, RAID controller modules, fans, and power supplies, gathered into enclosures. The physical disks are accessed through the RAID controller modules.

One or more host servers attached to the storage array can access the data on the storage array. You can also establish multiple physical paths between the hosts and the storage array so that loss of any single path (for example, through failure of a host server port) does not result in loss of access to data on the storage array.

The storage array is managed by MDSM running on a:

Page 6 of the Dell PowerVault MD3800f user manual — Related Documentation
Page 6 · click to enlarge
Page 6
  • Host server — On a host server system, MDSM and the storage array communicate management requests and event information using in-band or out-of band-connections.
  • Management station — On a management station, MDSM communicates with the storage array either through an Ethernet connection to the storage array management port or through an Ethernet connection to a host server. The Ethernet connection passes management information between the management station and the storage array connectivity.

Using MDSM, you can configure the physical disks in the storage array into logical components called disk groups or dynamic disk group and then divide the disk groups into virtual disks. Disk groups are created in the unconfigured capacity of a storage array. Virtual disks are created in the free capacity of a disk group.

Unconfigured capacity comprises physical disks not already assigned to a disk group. When a virtual disk is created using unconfigured capacity, a disk group or dynamic disk group is automatically created. If the only virtual disk in a disk group is deleted, the disk group is also deleted. Free capacity is space in a disk group that is not assigned to any virtual disk.

Data is written to the physical disks in the storage array using RAID technology. RAID levels define how data is written to physical disks. Different RAID levels offer different levels of accessibility, redundancy, and capacity. You can set a specified RAID level for each disk group and virtual disk on your storage array.

For more information about using RAID and managing data in your storage solution, see the Owner’s Manual at dell.com/support/manuals

Related Documentation

You product documentation includes:

  • Dell PowerVault MD3800f and MD3820f Storage Arrays Getting Started Guide — Provides an overview of system features, setting up your system, and technical specifications. This document is also shipped with your system.
  • Dell PowerVault MD3800f and MD3820f Storage Arrays Owner’s Manual — Provides information about system features and describes how to troubleshoot the system and install or replace system components.
  • Rack Installation Instructions — Describes how to install your system into a rack. This document is also shipped with your rack solution.
  • Dell PowerVault MD Series Storage Arrays Administrator's Guide — Provides information about configuring and managing the system using the MDSM GUI.
  • Dell PowerVault Modular Disk Storage Arrays CLI Guide — Provides information about configuring and managing the system using the MDSM CLI.
  • Dell PowerVault MD3800f and MD3820f Storage Arrays Deployment Guide — Provides information about deploying the storage system in the SAN architecture.
  • Dell PowerVault MD34/38 Series Support Matrix — Provides information about the software and hardware compatibility matrices for the storage array.
Page 7 of the Dell PowerVault MD3800f user manual — Locating your system Service Tag
Page 7 · click to enlarge
Page 7

Contacting Dell

Dell provides several online and telephone-based support and service options. If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer-service issues:

2. Select your country from the drop-down menu on the bottom right corner of the page.
3. For customized support:

a. Enter your system Service Tag in the Enter your Service Tag field. b. Click Submit.

The support page that lists the various support categories is displayed.

4. For general support:

a. Select your product category. b. Select your product segment. c. Select your product.

The support page that lists the various support categories is displayed.

Locating your system Service Tag

Your system is identified by a unique Express Service Code and Service Tag number. The Express Service Code and Service Tag are found on the front of the system by pulling out the information tag. Alternatively, the information may be on a sticker on the chassis of the system. This information is used by Dell to route support calls to the appropriate personnel.

Page 8 of the Dell PowerVault MD3800f user manual — Connecting The Storage Array
Page 8 · click to enlarge
Page 8

2 Hardware Installation

Before using this guide, ensure that you review the instructions in the documents:

  • Getting Started Guide — The Getting Started Guide shipped with the storage array provides information to configure the initial setup of the system.
  • Planning section of the Owner’s Manual — The planning section provides information about important concepts to set up your storage solution. See the Owner’s Manual at <a href="http://dell.com/support/" rel="nofollow noopener" target="_blank">dell.com/support/</a> manuals .
  • Rack Installation Instructions — Provides information on how to rack your system. This document is shipped with your system.

Planning The Storage Configuration

Consider the following before installing your storage array:

  • Evaluate data storage needs and administrative requirements.
  • Calculate availability requirements.
  • Decide the frequency and level of backups, such as weekly full backups with daily partial backups.
  • Consider storage array options, such as password protection and email alert notifications for error conditions.
  • Design the configuration of virtual disks, disk groups, or dynamic disk groups according to a data organization plan. For example, use one virtual disk for inventory, a second for financial and tax information, and a third for customer information.
  • Decide whether to allow space for hot spares, which automatically replace failed physical disks.

Connecting The Storage Array

The storage array is connected to a host using two hot-swappable RAID controller modules. The RAID controller modules are identified as RAID controller module 0 and RAID controller module 1. See the Owners Manual to know more about the functions of the different components of the storage controller.

The functions of the ports on each controller are described below:

  • 16 gbps Fibre Channel Host Ports (4) — Allows you to connect host servers to the storage array.
  • 12 gpbs SAS Host Ports (2) — Allows you to connect host servers to the storage array.
  • 1 gbps Ethernet Management (MGMT) Port (1) — Management port allows for out of band management of storage array.
  • Reserved Ethernet Port (1) — Reserved.
  • SAS Expansion Ports (2) — Allows you to connect the storage array to optional PowerVault MD1200 series expansion enclosures for additional storage capacity. Only one SAS OUT expansion port can be used at a time and the recommended expansion port is 0.
Page 9 of the Dell PowerVault MD3800f user manual — Configuring Fibre Channel
Page 9 · click to enlarge
Page 9

Each PowerVault MD3800f and MD3820f series storage array can be expanded to a maximum of 120 (or 192, if enabled using Premium Feature activation) physical slots.

Configuring Fibre Channel With Dell MD Series Storage Arrays

This section provides information about configuring Fibre Channel communication between the host server and the storage array. For basic setup information such as racking, power cabling, and recommended handling procedures, see the Getting Started Guide for your Storage Array at dell.com/ powervaultmanuals.

Configuring Fibre Channel On SAN Attached Storage Arrays

You can only cable the host server to the storage array via storage area network (SAN) using supported Fibre Channel switch(es).

The following steps shows the configuration order for connecting to a SAN. These steps assume you are setting up Fibre Channel storage for the first time.

Configuring Fibre Channel

To configure a Fibre Channel for connecting to a SAN:

1. Install the supported HBAs on your host server.
2. Cable the host server to the Fibre Channel switches.

For more information, see SAN-Attached Cabling Example and Remote Replication Cabling Example.

3. Install the required HBA drivers and firmware versions listed in the Dell PowerVault MD Series Support Matrix available at dell.com/powervaultmanuals.
4. Install and configure the MD Storage Manager software (included with your storage array) on your host server.
5. Cable the storage array to the Fibre Channel switches.
6. Configure zoning on all Fibre Channel switches.

For more information, see Switch Zoning Guidelines.

7. Using MDSM, configure the host servers, storage arrays, and virtual disks.
8. Activate and configure premium features (if applicable).
Page 10 of the Dell PowerVault MD3800f user manual — Using Fibre Channel Switch Zoning
Page 10 · click to enlarge
Page 10

Other Information You May Need

In addition to this document, see the documentation provided with the HBA and Fibre Channel switch hardware for vendor-specific information required to complete Fibre-Channel setup on your storage array.

Installing Supported Fibre Channel HBAs

The storage array supports a specific set of Fibre Channel HBAs, each requiring a unique driver and firmware level. See the Dell PowerVault MD Series Support Matrix at dell.com/powervaultmanuals for a list of supported HBAs.

If an HBA is already installed on your host server, verify that it is supported in the Dell PowerVault MD Series Support Matrix. If the HBA is not listed, it should not be used to connect to the storage array.

Installing Fibre Channel HBA On Your Host Server

For instructions about physically installing an HBA in your host server and loading supported drivers and firmware, see the documentation supplied with your HBA hardware.

Using Fibre Channel Switch Zoning

A Fibre Channel switch allows you to connect multiple devices to the SAN without compromising bandwidth or data throughput. Switch zoning implemented on each Fibre Channel switch hardware component using the manufacturer’s embedded utility, allows you to divide port traffic between the host server and storage array to maintain the highest level of redundancy.

The following figure shows each connection to the host server(s) routed to an individual logical zone on the SAN. Two physical switches provide an alternate (redundant) data path to the storage array. If a single HBA, switch or RAID controller fails, the host server(s) can still access data on the storage array through one of the alternate paths provided by the switches.

Page 11 of the Dell PowerVault MD3800f user manual — World Wide Name Zoning
Page 11 · click to enlarge
Page 11
Dell PowerVault MD3800f — World Wide Name Zoning diagram (page 11)
Fig. 1 · World Wide Name Zoning

Figure 1. Example of Switch Zoning on SAN on an MD38xxf-series Fibre-Channel Storage Array

World Wide Name Zoning

There are several different switch zoning techniques used across various SANs. When configuring zoning with your storage array, using a 64 bit World Wide Name (WWN) to uniquely identify each component in your Fibre Channel switch fabric is recommended. An advantage of using WWN port zoning (also called soft zoning) is that it allows you to remove and/or replace cabling to and from the fabric without reconfiguring the existing zone logic.

When implemented on the Fibre Channel switch, port WWN zoning causes the host server to query the World Wide Identifier (WWID) name of all attached physical disks and/or expansion enclosures each time it accesses the switch fabric. By zoning specific ports on the host server(s), switch and storage array

Page 12 of the Dell PowerVault MD3800f user manual — Redundant And Non-Redundant Cabling
Page 12 · click to enlarge
Page 12

together, the switch allows the host server to see only devices included in that zone, decreasing the amount of time it would otherwise take for the host server to query attached, but out-of-zone, devices.

Switch Zoning Guidelines

The storage array imposes specific requirements that must be followed when setting up Fibre Channel switch zoning:

  • If a Fibre Channel switch is used to connect your host server and storage array, it must be zoned. Unzoned or open switches cannot be used.
  • WWN port zoning is recommended. While hard zoning (zoning by device ID) is supported, LUN masking uses the WWN identifier. You can mix WWN and hard-zoned ports in the same zone.
  • Multi-port HBAs are supported. Each port in a multiple-port HBA represents one initiator. Each initiator must be connected to a single logical switch zone.
  • No more than four paths (port-to-port segments) can be established from a single, physical host server(s) to a single RAID controller.
  • A zone can contain multiple targets and span multiple storage arrays (single initiator can point to multiple targets).
  • If the Remote Replication premium feature is activated, a separate zone for each replication port is required. Only data traffic related to Remote Replication can move through that zone. For more details and requirements regarding Remote Replication, see the Dell PowerVault MD Series Storage Arrays Administrator's Guide at <a href="http://dell.com/powervaultmanuals" rel="nofollow noopener" target="_blank">dell.com/powervaultmanuals</a> .

Setting Up Zoning On The Fibre Channel Switch Hardware

Setting up zoning on Fibre Channel switches varies greatly between manufacturers. For detailed information on how to set up zoning on your switch, see the manufacturer’s product documentation or technical support website.

Cabling The Storage Array

Cabling the storage array depends on a number of factors such as:

  • Required level of redundancy or throughput
  • Number of host servers connected to the storage array
  • Type of HBAs (dualor single-port) used in the host server(s)
  • Remote Replication premium feature (if applicable)

The cabling diagrams shown here do not represent every supported cabling scenario but the concepts of redundancy and switch logic can be used to build your own configuration.

Redundant And Non-Redundant Cabling

Non-redundant cabling configurations provide a single data path from host server(s) to the storage array. This type of configuration is only recommended for non-critical data storage. A path failure from a failed or removed cable, failed HBA, or failed or removed RAID controller module results in loss of host access to the storage array.

Redundant configurations establish separate data paths between the host server(s) and storage array. Each path is connected to separate RAID controller modules in the storage array. Redundancy protects

Page 13 of the Dell PowerVault MD3800f user manual — SAN-Attached Cabling Example
Page 13 · click to enlarge
Page 13

the host server(s) from losing access to data in the event of a path failure since both RAID controller modules can independently access all the physical disks in the storage array.

SAN-Attached Cabling

SAN-attached cabling configurations provide the highest level of redundancy and alternate-path connectivity between the host server and storage array. A SAN configuration using a Fibre Channel compatible switch fabric allows you to establish multiple redundant paths to data on the storage array.

SAN-Attached Cabling Example

The following figure shows a three-server, mixed HBA cabling configuration that uses two separate switch fabrics to establish multiple paths to the storage array. Port-to-port connections in each switch fabric/zone are detailed in the text boxes.

Page 14 of the Dell PowerVault MD3800f user manual — SAN-Attached Cabling
Page 14 · click to enlarge
Page 14
Dell PowerVault MD3800f — SAN-Attached Cabling diagram (page 14)
Fig. 2 · SAN-Attached Cabling

Figure 2. Three SAN-Attached Host Servers Connected to a Storage Array Using Multiple Paths

Switch Fabric A Switch Fabric B

Show 7 more labels / short text on this page
Zone1_Server1_HBA_0 Zone4_Server1_HBA_1 · Server1_HBA_0 Server1_HBA_1 · Array1_Ctrl-0-0 Array1_Ctrl-0-1 · Array1_Ctrl-0-3 Array1_Ctrl-0-2 · Array1_Ctrl-1-0 Array1_Ctrl-1-1 · Array1_Ctrl-1-2 Array1_Ctrl-1-3 · Zone2_Server2_HBA_0 Zone5_Server2_HBA_1
Page 15 of the Dell PowerVault MD3800f user manual — Remote Replication Cabling Example
Page 15 · click to enlarge
Page 15

Switch Fabric A Switch Fabric B

Remote Replication Cabling Example

Remote Replication is a storage array premium feature that provides online, real-time replication of data between storage arrays. When this feature is activated, a dedicated port (port 3) on each RAID controller is reserved exclusively for Remote Replication traffic. No other data traffic is allowed on that port until the Remote Replication feature is deactivated. A dedicated zone on each Fibre Channel switch is also required.

Show 11 more labels / short text on this page
Server2_HBA_0 Server2_HBA_1 · Array1_Ctrl-0-0 Array1_Ctrl-0-1 · Array1_Ctrl-0-3 Array1_Ctrl-0-2 · Array1_Ctrl-1-0 Array1_Ctrl-1-1 · Array1_Ctrl-1-2 Array1_Ctrl-1-3 · Zone3_Server3_HBA_0 Zone6_Server3_HBA_1 · Server3_HBA_0 Server3_HBA_1 · Array1_Ctrl-0-0 Array1_Ctrl-0-1 · Array1_Ctrl-0-3 Array1_Ctrl-0-2 · Array1_Ctrl-1-0 Array1_Ctrl-1-1 · Array1_Ctrl-1-2 Array1_Ctrl-1-3
Page 16 of the Dell PowerVault MD3800f user manual — Remote Replication Cabling Example
Page 16 · click to enlarge
Page 16
Dell PowerVault MD3800f — Remote Replication Cabling Example diagram (page 16)
Fig. 3 · Remote Replication Cabling Example

Figure 3. Remote Replication Cabling

Switch Fabric A Switch Fabric B

Show 12 more labels / short text on this page
Zone1_Server1_HBA_0 Zone6_Server1_HBA_1 · Server1_HBA_0 Server1_HBA_1 · Array1_Ctrl-0-0 Array1_Ctrl-0-1 · Array1_Ctrl-1-0 Array1_Ctrl-0-2 · Array1_Ctrl-1-2 Array1_Ctrl-1-1 · Zone2_Server2_HBA_0_0 Zone7_Server2_HBA_0_1 · Server2_HBA_0_0 Server2_HBA_0_1 · Array1_Ctrl-0-0 Array1_Ctrl-0-1 · Array1_Ctrl-1-0 Array1_Ctrl-0-2 · Array1_Ctrl-1-2 Array1_Ctrl-1-1 · Zone3_Server2_HBA_1_0 Zone8_Server2_HBA_1_1 · Server2_HBA_1_0 Server2_HBA_1_1
Page 17 of the Dell PowerVault MD3800f user manual — Mixed Environment
Page 17 · click to enlarge
Page 17

Switch Fabric A Switch Fabric B

Mixed Environment

The following figure shows mixed configuration, that is SAS direct attached and host connectivity via the SAN (that is FC/Ethernet switch).

Show 16 more labels / short text on this page
Array1_Ctrl-0-0 Array1_Ctrl-0-1 · Array1_Ctrl-1-0 Array1_Ctrl-0-2 · Array1_Ctrl-1-2 Array1_Ctrl-1-1 · Zone4_Server3_HBA_0_1 Zone9_Server3_HBA_0_0 · Server3_HBA_0_1 Server3_HBA_0_0 · Array2_Ctrl-0-1 Array2_Ctrl-0-0 · Array2_Ctrl-0-2 Array2_Ctrl-1-0 · Array2_Ctrl-1-1 Array2_Ctrl-1-2 · Zone5_Server3_HBA_1_1 Zone10_Server3_HBA_1_0 · Server3_HBA_1_1 Server3_HBA_1_0 · Array2_Ctrl-0-1 Array2_Ctrl-0-0 · Array2_Ctrl-0-2 Array2_Ctrl-1-0 · Array2_Ctrl-1-1 Array2_Ctrl-1-2 · Replication_Zone_1 Replication_Zone_2 · Array1_Ctrl-0-3 Array1_Ctrl-1-3 · Array2_Ctrl-0-3 Array2_Ctrl-1-3
Page 18 of the Dell PowerVault MD3800f user manual — Expanding With Previously Configured PowerVault MD1200 Series Expansion Enclosures
Page 18 · click to enlarge
Page 18
Dell PowerVault MD3800f — Cabling PowerVault MD1200 Series Expansion Enclosures diagram (page 18)
Fig. 4 · Cabling PowerVault MD1200 Series Expansion Enclosure…

Figure 4. Mixed Environment

Cabling PowerVault MD1200 Series Expansion Enclosures

You can expand the capacity of your PowerVault MD3800i and MD3820i series storage array by adding PowerVault MD1200 series expansion enclosures. You can expand the physical disk pool to a maximum of 120 (or 192, if enabled using Premium Feature activation) physical disks using a maximum of seven expansion enclosures.

Expanding With Previously Configured PowerVault MD1200 Series Expansion Enclosures

Use this procedure if your expansion enclosure is directly attached and configured with a Dell PowerEdge RAID Controller (PERC) H800 adapter. Data from virtual disks created on a PERC H800 adapter cannot be directly migrated to a storage array or an expansion enclosure connected to a storage array.

Page 19 of the Dell PowerVault MD3800f user manual — Expanding With New PowerVault MD1200 Series Expansion Enclosures
Page 19 · click to enlarge
Page 19
1. Back up all data on the expansion enclosures.
2. Upgrade the expansion enclosure firmware to the latest version available at dell.com/support while the enclosure is still attached to the PERC H800 controller.

Windows systems users can reference the DUP.exe package and Linux kernel users can reference the DUP.bin package.

3. Ensure that the storage array software is installed and up to date before adding the expansion enclosures. For more information, see the Dell PowerVault MD34xx/MD38xx Support Matrix at dell.com/support/manuals. a. Install the software and driver package included on the PowerVault MD series resource media. For information about installing the software, see the topic “Installing PowerVault MD Storage Software”. b. Update the storage array RAID controller module firmware and NVSRAM to the latest versions

available at dell.com/support c. Using MDSM, click Tools → Upgrade RAID Controller Module Firmware → Enterprise

Management Window (EMW).

4. Stop all I/O and turn off the system and attached units. a. Stop all I/O to the storage array and turn off the host systems attached to the storage array. b. Turn off the storage array. c. Turn off the expansion enclosures in the affected system.
5. Cable the expansion enclosures to the storage array. a. Connect the MiniSAS HD end of the supported SAS cabled to the SAS OUT Port 0 on the MD 1200 series expansion enclosure. b. Connect the other end of the SAS cable to the IN port on the MD 1200 series expansion

enclosure.

6. Turn on attached units: a. Turn on the expansion enclosures. Wait for the enclosure status LED to light blue. b. Turn on the storage array and wait for the status LED to indicate that the unit is ready:
  • If the status LEDs are solid amber, the storage array is still coming online.
  • If the status LEDs are blinking amber, there is an error that can be viewed using the MDSM.
  • If the status LEDs are solid blue, the storage array is ready. c. After the storage array is online and ready, turn on any attached host systems.
7. After the PowerVault MD1200 series expansion enclosure is configured as an expansion enclosure of the storage array, restore the data that was backed up in step 1.

After the expansion enclosures are online, they can be accessed as a part of the storage array.

Expanding With New PowerVault MD1200 Series Expansion Enclosures

Perform the following steps to attach new PowerVault MD1200 series expansion enclosures to a PowerVault MD34xx/38xx series storage arrays:

1. Before adding the expansion enclosures, ensure that the storage array software is installed and is up to date. For more information, see the Dell PowerVault MD34xx/38xx Support Matrix at dell.com/ support/manuals . a. Install the software and driver package included on the PowerVault MD series resource media. For information about installing the software, see the topic “Installing PowerVault MD Storage Software”.
Page 20 of the Dell PowerVault MD3800f user manual — Expanding With New PowerVault MD1200 Series Expansion Enclosures
Page 20 · click to enlarge
Page 20

b. Set up the PowerVault MD1200 series expansion enclosures. For information about setting up the

PowerVault MD1200 series expansion enclosures, see the Owner’s Manual at dell.com/support/ manuals. c. Using MDSM, update the RAID controller module firmware and NVSRAM to the latest versions

available on dell.com/support/manuals d. Click Tools → Upgrade RAID Controller Module Firmware from the Enterprise Management

Window (EMW).

2. Stop I/O and turn off all systems:

a. Stop all I/O to the storage array and turn off affected host systems attached to the storage array. b. Turn off the storage array. c. Turn off any expansion enclosures in the affected system.

3. Cable the expansion enclosures to the storage array.

a. Connect the MiniSAS HD end of the supported SAS cabled to the SAS OUT Port 0 on the MD 1200 series expansion enclosure. b. Connect the other end of the SAS cable to the IN port on the MD 1200 series expansion

enclosure.

4. Turn on attached units:

a. Turn on the expansion enclosures. Wait for the enclosure status LED to light blue. b. Turn on the storage array and wait for the status LED to indicate that the unit is ready:

  • If the status LEDs are solid amber, the storage array is still coming online.
  • If the status LEDs are blinking amber, there is an error that can be viewed using MDSM.
  • If the status LEDs are solid blue, the storage array is ready. c. After the storage array is online and ready, turn on any attached host systems.
5. Using MDSM, update all attached expansion enclosure firmware if it is out of date:

a. From the EMW, select the enclosure that you want to update and enter the Array Management Window (AMW). b. Click Advanced → Maintenance → Download → EMM Firmware. c. Select Select All to update all the attached expansion enclosures simultaneously.

Page 21 of the Dell PowerVault MD3800f user manual — 3 Installing PowerVault MD Storage Software
Page 21 · click to enlarge
Page 21

3 Installing PowerVault MD Storage Software

The Dell PowerVault MD series resource media contains software and drivers for both Linux and Microsoft Windows operating systems.

The root of the media contains a readme.txt file covering changes to the software, updates, fixes, patches, and other important data applicable to both Linux and Windows operating systems. The readme.txt file also specifies requirements for accessing documentation, information regarding versions of the software on the media, and system requirements for running the software.

For more information on supported hardware and software for Dell PowerVault systems, see the Dell PowerVault MD34xx/38xx Series Support Matrix at dell.com/support/manuals

The PowerVault MD series resource media provides features that include the core software, providers, and utilities. The core software feature includes the host-based storage agent, multipath driver, and Modular Disk Storage Manager (MDSM) application used to configure, manage, and monitor the storage array solution. The providers feature includes providers for the Microsoft Virtual Disk Service (VDS) and Microsoft Volume Shadow-Copy Service (VSS) framework.

If Dynamic Host Configuration Protocol (DHCP) is not used, during initial configuration of the management station, at least one network adapter must be configured on the same IP subnet as the storage array’s default management port (Controller 0 MGMT (port 1): 192.168.129.101 or Controller 1 MGMT (port 1): 192.168.129.102). After initial configuration, the management ports are configured using MDSM and the management station’s IP address can be changed back to the previous settings.

The PowerVault MD series resource media offers the following three installation methods:

  • Graphical Installation (Recommended) — This is the recommended installation procedure for most users. The installer presents a graphical wizard-driven interface that allows customization of which components are installed.
  • Console Installation — This installation procedure is useful for Linux users that do not desire to install an X-Window environment on their supported Linux platform.
  • Silent Installation — This installation procedure is useful for users that prefer to create scripted installations.
Page 22 of the Dell PowerVault MD3800f user manual — Graphical Installation (Recommended)
Page 22 · click to enlarge
Page 22

Installing Host Bus Adapters and Drivers

Ensure that you read the Configuring Fibre Channel With the Dell PowerVault MD Series Storage Arrays document before continuing with this procedure.

1. Install the host bus adapters (HBAs).
2. Connect the cables.
3. Install the HBA drivers and the operating system HBA patches/hotfixes
4. Ensure that the recommended HBA settings are applied.

Graphical Installation (Recommended)

1. Insert the PowerVault MD series resource media.

Depending on your operating system, the installer may launch automatically. If the installer does not launch automatically, navigate to the root directory of the installation media (or downloaded installer image) and run the md_launcher.exe file. For Linux-based systems, navigate to the root of the resource media and run the autorun file.

2. Select Install MD Storage Software .
3. Read and accept the license agreement.
4. Select one of the following installation options from the Install Set dropdown menu:
  • Full (recommended) — Installs the MD Storage Manager (client) software, host-based storage agent, multipath driver, and hardware providers.
  • Host Only — Installs the host-based storage agent and multipath drivers.
  • Management — Installs the management software and hardware providers.
  • Custom — Allows you to select specific components. 5. Choose whether to start the event monitor service automatically when the host server reboots or manually.
6. Confirm the installation location and choose Install .
7. If prompted, reboot the host server after the installation completes.
8. Start MD Storage Manager and discover the arrays.
9. If applicable, activate any premium features purchased with your storage array. If you purchased premium features, see the printed activation card shipped with your storage array.
Page 23 of the Dell PowerVault MD3800f user manual — Enabling Premium Features (Optional)
Page 23 · click to enlarge
Page 23

Console Installation

The autorun script in the root of the resource media detects when there is no graphical environment running and automatically starts the installer in a text-based mode. This mode provides the same options as graphical installation with the exception of the MDCU specific options. The MDCU requires a graphical environment to operate.

Silent Installation

Silent Installation On Windows Systems

To run silent installation on a Windows system:

1. Copy the custom_silent.properties file in the /windows folder of the installation media or image to a writable location on the host server.
2. Modify the custom_silent.properties file to reflect the features, models, and installation options to be used. Then, save the file.
3. Once the custom_silent.properties file is revised to reflect your specific installation, run the following command to begin the silent installation: mdss_install.exe –f \ custom_silent.properties.

Silent Installation On Linux Systems

1. Copy the custom_silent.properties file in the /linux folder of the installation media or image to a writable location on the host server.
2. Modify the custom_silent.properties file to reflect the features, models, and installation options to be used. Then, save the file.
3. Once the custom_silent.properties file is revised to reflect your specific installation, run the following command to begin the silent installation:mdss_install.bin –f / custom_silent.properties.

Enabling Premium Features (Optional)

If you ordered premium features, follow the instructions on the Premium Features card to install the additional features.

Page 24 of the Dell PowerVault MD3800f user manual — Upgrading MD Storage Software
Page 24 · click to enlarge
Page 24

Upgrading MD Storage Software

To upgrade from a previous version of the MDSM application, uninstall the previous version (see Uninstalling MD Storage Software), and then follow the instructions in this chapter to install the new version.

Page 25 of the Dell PowerVault MD3800f user manual — Verifying Storage Array Discovery
Page 25 · click to enlarge
Page 25

4 Post Installation Tasks

Before using the Dell PowerVault storage array for the first time, complete these initial configuration tasks in the order shown. These tasks are performed using the MD Storage Manager (MDSM) software.

1. For out-of-band management, you must set the network configuration for each RAID controller module, including its Internet Protocol (IP) address, subnetwork mask (subnet mask), and gateway.
2. Start MDSM.
  • Click Start → Programs → Dell → MD Storage Manager → Modular Disk Storage Manager Client on Microsoft Windows operating systems.
  • Click the PowerVault MD Storage Manager desktop icon on Linux operating systems.
  • You can also launch PowerVault MD Storage Manager in Linux by running the following commands at the command prompt: cd /opt/dell/mdstoragesoftware/ mdstoragemanager /client./SMclient
3. Go to Setup → Add Storage Array and start the automatic discovery of systems in the Enterprise Management Window (EMW).

After discovery is complete, a confirmation screen is displayed.

4. Click Close to close the screen.

Verifying Storage Array Discovery

The Automatic Discovery option automatically discovers both in-band and out-of-band arrays and adds the storage arrays to the management domain. If the out-of-band or in-band connections shown on the summary page are not accurate, complete the following steps. For more information, see the Online Help.

1. Check the hardware and connections for possible problems. For specific procedures on troubleshooting interface problems, see the Owner's Manual at support.dell.com/manuals.
2. Verify that the array is on the local subnetwork. If it is not, click the new link to manually add it.
3. Verify that the status of each storage array is Optimal . If any array shows an Unresponsive status, complete one of the following steps:

a. To remove the array from the management domain, highlight the array and then click Remove link. b. To add an array, click New link.

In Linux, click the Manual button and click OK.

Page 26 of the Dell PowerVault MD3800f user manual — Initial Setup Tasks
Page 26 · click to enlarge
Page 26
4. If the array still shows an Unresponsive status, contact Dell.

Initial Setup Tasks

Enter the context of your task here (optional). This is where introductory content goes.

1. The name of the first storage array found is displayed in the Devices tab of the EMW. To see a list of all storage arrays found on the local network, expand the discovered storage arrays tab in the Device pane of the EMW.
2. The default name for a newly installed MDxxxxx series storage array is Unnamed . If another name is displayed in MDSM, click the down arrow next to the name and click Unnamed in the drop-down list.
3. Double-click on the discovered array to launch the array management window and edit the configuration of the array.
4. Click Perform Initial Setup Tasks to see an outline and links to the remaining postinstallation tasks. The array is now ready to be configured.

See the Owner’s Manual for information about each task and to perform the necessary configuration steps.

The following table lists the recommended configuration steps that can be accomplished using the Owner’s Manual.

Table 1. Initial Setup Tasks Dialog Box

Rename the storage array To provide a more meaningful name than the software-assigned label, Unnamed.

Set a storage array password To restrict unauthorized access. MDSM may ask for a password before changing the configuration or performing a destructive operation

Set up alert notifications To notify individuals (by email) and/or storage enterprise management consoles, such as Dell Management Console, (by SNMP) when a storage array component degrades or fails, or an adverse environmental condition occurs.

Set up email alerts

Set up SNMP alerts

Configure a storage array To create virtual disks and map them to hosts.

Task Purpose

Page 27 of the Dell PowerVault MD3800f user manual — Uninstalling MD Storage Software From Linux
Page 27 · click to enlarge
Page 27

5 Uninstalling MD Storage Software

Uninstalling MD Storage Software From Windows

1. From the Control Panel, double-click Add or Remove Programs .
2. Select MD Storage Software from the list of programs.
3. Click Change/Remove .

The Uninstall Complete window is displayed.

4. Follow the instructions on screen.
5. Select Yes to restart the system, and then click Done .

Uninstalling MD Storage Software From Windows Server GUI Versions

1. From the Control Panel , double-click Programs and Features .
2. Select MD Storage Software from the list of programs.
3. Click Uninstall/Change .

The Uninstall Complete window is displayed.

4. Follow the instructions on screen.
5. Select Yes to restart the system, then click Done .

Uninstalling MD Storage Software From Windows Server Core Versions

1. Navigate to the \Program Files\Dell\MD Storage Software\Uninstall Dell MD Storage Software directory.
2. From the installation directory, type Uninstall Dell MD Storage Software and press .
3. From the Uninstall window, click Next and follow the instructions on the screen.
4. Select Yes to restart the system, then click Done .

Uninstalling MD Storage Software From Linux

1. By default, MD Storage Manager is installed in the /opt/dell/mdstoragemanager directory.

If another directory was used during installation, navigate to that directory before beginning the uninstallation procedure.

2. From the installation directory, open the Uninstall Dell MD Storage Software directory and run the file Uninstall Dell MD Storage Software.exe .

When the uninstallation is complete, it goes back to the root prompt.

Page 28 of the Dell PowerVault MD3800f user manual — Least Path Weight
Page 28 · click to enlarge
Page 28

6 Load Balancing

Load Balance Policy

Multi-path drivers select the I/O path to a virtual disk through a specific RAID controller module. When the multi-path driver receives a new I/O to process, the driver tries to find a path to the current RAID controller module that owns the virtual disk. If the path to the current RAID controller module that owns the virtual disk cannot be found, the multi-path driver migrates the virtual disk ownership to the secondary RAID controller module. When multiple paths to the RAID controller module that owns the virtual disk exist, you can choose a load balance policy to determine which path is used to process I/O. Multiple options for setting the load balance policies let you optimize I/O performance when mixed host interfaces are configured.

You can choose one of the following load balance policies to optimize I/O performance:

  • Round robin
  • Least queue depth
  • Least path weight (Microsoft Windows operating systems only)

Round Robin With Subset

The round robin with subset I/O load balance policy routes I/O requests, in rotation, to each available data path to the RAID controller module that owns the virtual disks. This policy treats all paths to the RAID controller module that owns the virtual disk equally for I/O activity. Paths to the secondary RAID controller module are ignored until ownership changes. The basic assumption for the round-robin policy is that the data paths are equal. With mixed host support, the data paths might have different bandwidths or different data transfer speeds.

Least Queue Depth

The least queue depth policy is also known as the least I/Os or least requests policy. This policy routes the next I/O request to a data path that has the least outstanding I/O requests queued. For this policy, an I/O request is simply a command in the queue. The type of command or the number of blocks that are associated with the command are not considered.

The least queue depth policy treats large block requests and small block requests equally. The data path selected is one of the paths in the path group of the RAID controller module that owns the virtual disk.

Least Path Weight

The least path weight policy assigns a weight factor to each data path to a virtual disk. An I/O request is routed to the path with the lowest weight value to the RAID controller module that owns the virtual disk.

Page 29 of the Dell PowerVault MD3800f user manual — Setting Load Balance Policies in VMware
Page 29 · click to enlarge
Page 29

If more than one data path to the virtual disk has the same weight value, the round robin with subset path selection policy is used to route I/O requests between the paths with the same weight value. The least path weight load balance policy is not supported on Linux operating systems.

Changing Load Balance Policies On The Windows Server Operating System

Load balancing with the PowerVault MD series storage array can be done from the default round robin with subset by using either the:

  • Device manager
  • Disk management

Changing Load Balance Policies Using Windows Server Device Manager

Follow the steps to change the load balance policy using Windows Server device manager:

1. Right-click My Computer and select Manage to open the Computer Management dialog box.
2. Click Device Manager to show the list of devices attached to the host.
3. Right-click the multipath disk device for which you want to set the load balance policies, then select Properties .
4. From the MPIO tab, select the load balance policy that you want to set for this disk device.

Changing Load Balance Policies Using Windows Server Disk Management

Follow the steps to change the load balance policy using disk management:

1. Right-click My Computer and click Manage to open the Computer Management dialog box.
2. Click Disk Management to show the list of virtual disks attached to the host.
3. Right-click the virtual disk for which you want to set the load balance policy, then click Properties .
4. From the MPIO tab, select the load balance policy that you want to set for this virtual disk.

Setting Load Balance Policies in Linux

Linux only supports round robin based load balancing. For more information, see Round Robin With Subset.

Setting Load Balance Policies in VMware

VMware supports Asymmetric Logical Unit Access (ALUA). For more information on Most Recently Used (MRU) and Round Robin (RR) load balancing policies, see VMware documents.

Page 30 of the Dell PowerVault MD3800f user manual — Removing SFP+ Modules
Page 30 · click to enlarge
Page 30

7 Working With SFP+ Modules and Fiber Optic Cables

Each storage controller can have up to four FC host ports. A small-form-factor pluggable (SFP+) module is used to connect a host port to a host or switch. The SFP+ module is inserted into the port, and then a fiber optic cable is inserted into the SFP+ module. The other end of the fiber optic cable is connected to an optical interface connector either in a FC HBA on a host or a switch. SFP+ modules are laser products.

Guidelines for Using SFP+ Modules

The storage array requires SFP+ modules. SFP+ modules convert electrical signals to optical signals that are required for FC transmission to and from RAID controller modules. After installing the SFP+ modules, fiber-optic cables are used to connect the storage array to other FC devices. Before installing SFP+ modules and fiber-optic cables, read the following information:

  • Use only Dell supported SFP+s with the Dell PowerVault MD3600f series storage arrays. Other generic SFP+s are not supported and may not work with the storage arrays.
  • The SFP+ module housing has an integral guide key that is designed to prevent you from inserting the SFP+ module incorrectly.
  • Use minimal pressure when inserting an SFP+ module into a FC port. Forcing the SFP+ module into a port may damage the SFP+ module or the port.
  • Use minimal pressure when inserting an SFP+ module into a FC port. Forcing the SFP+ module into a port may damage the SFP+ module or the port.
  • You must install the SFP+ module into a port before you connect the fiber-optic cable
  • You must remove the fiber-optic cable from the SFP+ module before you remove the SFP+ module from the port.

Removing SFP+ Modules

To remove SFP+ modules:

1. Remove the FC cable from the SFP+ module.

See Working With SFP+ Modules and Fiber Optic Cables

2. Unlock the SFP+ module latch. For SFP+ modules that contain wire tabs, unlock the SFP+ module latch by pulling the wire latch outward 90°.
Page 31 of the Dell PowerVault MD3800f user manual — Installing Fibre Channel Cables
Page 31 · click to enlarge
Page 31
3. With the SFP+ module latch in the unlocked position, remove the SFP+ module. For SFP+ modules that contain wire tabs, grasp the wire latch and pull the SFP+ module out of the port.
4. Replace the protective cap on the SFP+ module and the host port.
5. Place the SFP+ module into a static-protective package.

Installing SFP+ Modules

To install SFP+ modules:

1. If all the FC IN ports have an SFP+ module installed, go to step 5.
2. Remove the SFP+ module from the static protective package.
3. Remove the protective cap from the SFP+ module and SFP+ port.
4. Insert the SFP+ module into the host port until it clicks into place.
5. Connect an FC cable.

See Installing Fibre Channel Cables.

Guidelines for Using Fiber Optic Cables

  • Do not route the cable along a folding cable management arm.
  • For devices on slide rails, leave enough slack in the cables so they do not bend to a diameter of less than 76 mm (3"), or a radius less than 38 mm (1.5"), when extended or become pinched when retracted.
  • Route the cable away from places where it can be damaged by other devices in the rack cabinet.
  • Do not use plastic cable ties in place of the provided cable straps.
  • Do not overtighten the cable straps or bend the cables to a diameter of less than 76 mm (3") or a radius less than 38 mm (1.5").
  • Do not place excess weight on the cable at the connection point. Ensure that the cable is supported.

Removing Fibre Channel Cables

1. Press and hold the lever to release the latches before removing the cable from the SFP+ module. Ensure that the levers are in the released position when removing the cable. Do not grasp the SFP+ module plastic tab when removing the cable.
2. On the end of the cable that connects into the SFP+ module or HBA, press down and hold the lever to release the latches.
3. While pressing down the cable lever, pull the connector to remove the cable from the SFP+ module.
4. Replace the protective caps on the cable ends.
5. Replace the protective cap on the SFP+ module.

Installing Fibre Channel Cables

Page 32 of the Dell PowerVault MD3800f user manual — Installing SFP+ Modules
Page 32 · click to enlarge
Page 32

Before installing an FC cable, see Guidelines for Using Fiber Optic Cables.

1. If applicable, remove the protective cap from the SFP+ module and store the protective cap for future use.
2. Remove the two protective caps from one end of the cable and store them for future use.
3. Insert the cable into an SFP+ module that is installed in the storage array. The cable connector is keyed for correct installation. Holding the connector, push in the cable until it clicks into place.
4. Remove the two protective caps from the other end of the cable and store them future use.
5. Connect this end of the cable to one of the following devices:
  • An SFP+ module that is installed in an FC switch port
  • An FC HBA port
Page 33 of the Dell PowerVault MD3800f user manual — Cabling for Performance
Page 33 · click to enlarge
Page 33

8 Hardware Cabling Best Practices

Handling Static-Sensitive Components

Static electricity can damage memory modules, system boards, and other static-sensitive components. To prevent damaging the system, follow these precautions:

  • Move and store all components in the static-protective packaging.
  • Place components on a grounded surface before removing them from their static-protective packaging.
  • Grounded surfaces include static-dissipating mats or grounded workstations.
  • Always be properly grounded when touching a static-sensitive component. To properly ground yourself, wear a wrist strap or boot strap made for this purpose.
  • Handle the component by its edges. Do not touch solder joints, pins, or printed circuitry.
  • Use conductive field service tools.

Host Cabling for Remote Replication

The Remote Replication premium feature provides online, real-time replication of data between storage arrays over a remote distance. In the event of a disaster or a catastrophic failure at one storage array, a second storage array can be promoted to take over responsibility for computing services. The Remote Replication premium feature requires a dedicated host port for replicating data between storage arrays. After the Remote Replication premium feature has been activated, one host I/O port on each RAID controller module is solely dedicated to replicating operations.

Cabling for Performance

Data transfer performance is enhanced by maximizing bandwidth, which is the ability to process more I/O across more channels. Therefore, a configuration that maximizes the number of host channels and the number of drive channels available to process I/O maximizes performance. Faster processing speeds also maximize performance.

In addition to planning a topology that provides maximum performance, choose a RAID level that suits the planned applications.

Page 34 of the Dell PowerVault MD3800f user manual — Labeling Cables
Page 34 · click to enlarge
Page 34

Single-Controller and Dual-Controller Topologies

While creating a topology for a RAID enclosure that contains only one RAID controller module, attach expansion enclosures that contain only one single environmental services monitor (ESM). Do not attach an expansion enclosure that contains two ESMs to a single-controller RAID enclosure.

Labeling Cables

Cabling is an important part of creating a robust storage array. Labeling the cables identifies system components and drive channels. System maintenance is easier when the cables are correctly identified. Label both ends of each cable. You can use adhesive office labels that are folded in half over the ends of each cable. Mark the labels with the port identifiers to which the cable is connected. Additional information can be provided by using color-coded cable straps (or ties) to group all cables associated with one component or drive channel.

If a component fails, the cables must be disconnected, the failed component replaced, and the cables reattached. Detailed labeling of the cables simplifies the component replacement process.

If you are adding a new expansion enclosure to an existing configuration, correctly labeled cables helps identify where to connect the new enclosure.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Dell PowerVault MD3800f

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Dell PowerVault MD3800f

Be the first to ask — other owners or our team will answer.

Original document

Dell PowerVault MD3800f manual PDF

34 pages·1.2 MB·Outdoor Storage·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…