EN
Dell logo
Official user manual

Dell PowerEdge H200

92 pages·4.2 MB·Video Gaming Accessories·PDF·ENDEFRITNLJA
Dell PowerEdge H200
Table of Contents 81 sections CAUTION: Safety Instructions · SAFETY: General · SAFETY: When Working Inside Your System · Protecting Against Electrostatic Discharge · … ShowHide
CAUTION: Safety Instructionsp.9SAFETY: Generalp.9SAFETY: When Working Inside Your Systemp.10Protecting Against Electrostatic Dischargep.10SAFETY: Battery Disposalp.11Overviewp.13Operating System Supportp.14About RAIDp.15RAID Levelsp.15RAID Terminologyp.15RAID 0p.15RAID 1p.16RAID 10p.17PERC H200 and 6Gbps SAS HBA Featuresp.19LED Port Activity Feature for 6Gbps SAS HBA Onlyp.23Physical Disk Cache Policyp.24Unsupported Drivesp.24Hardware Installationp.25Installing the PERC H200 and 6Gbps SAS HBA Cardsp.25Installing the PERC H200 Modular Cardp.29Driver Installationp.31Installing the Windows Driverp.32Creating the Driver Mediap.32Pre-Installation Requirementsp.32Installing the Driver During a Windows Server 2003 Operating System Installationp.33Installing the Driver During a Windows Server 2008 or Windows Server 2008 R2 Installationp.34Installing a Windows Server 2003, Windows Server 2008 or Windows Server 2008 R2 Driver for a New RAID Controllerp.35Updating the Windows Driverp.36Installing Linux Driverp.37Creating a DUDp.37Creating a DUD Using DKMSp.39Installing Red Hat Enterprise Linux Operating System Using the DUDp.39Installing SUSE Linux Enterprise Server Using the DUDp.40Installing the RPM Package With DKMS Supportp.41Upgrading the Kernelp.41PERC H200 and 6Gbps SAS HBA BIOSp.43POST Messagesp.43BIOS Fault Code Messagesp.43Booting With Multiple Controllersp.44Configuration Utilityp.44Starting the Configuration Utilityp.44Functions Performedp.44RAID Configuration and Management Screensp.46Select New Volume Typep.47Create New Volumep.47View Volumep.50Manage Volumep.50Exit Screenp.51Performing Configuration Tasksp.51Creating a RAID 0 Virtual Diskp.52Creating a RAID 1 Virtual Diskp.53Creating a RAID 10 Virtual Diskp.54Viewing Virtual Disk Propertiesp.56Activating a Virtual Diskp.56Migrating and Activating a Virtual Diskp.57Deleting a Virtual Diskp.57Hot Spare Failoverp.58Replacing and Rebuilding a Degraded Virtual Diskp.58Assigning a Preferred Boot Devicep.59Troubleshootingp.61BIOS Boot Orderp.61Background Activitiesp.61General Issuesp.62Physical Disk Related Issuesp.63Configuration Utility Error Messagesp.64BIOS Error Messagesp.65Updating the Firmwarep.71Firmware Package Update Utilityp.71Getting Helpp.73Technical Support and Customer Servicep.73Online Servicesp.74Automated Order-Status Servicep.75Dell Enterprise Trainingp.75Problems With Your Orderp.75Product Informationp.75Returning Items for Warranty Repair or Creditp.76Before You Callp.76Regulatory Noticesp.77Corporate Contact Details (Taiwan Only)p.79Glossaryp.81Indexp.91
Page 1 of the Dell PowerEdge H200 user manual — Dell™ PowerEdge™ RAID Controller (PERC) H200 and
Page 1 · click to enlarge
Page 1

Dell™ PowerEdge™ RAID Controller (PERC) H200 and

6Gbps SAS HBA

User’s Guide

Page 2 of the Dell PowerEdge H200 user manual — Notes, Cautions, and Warnings
Page 2 · click to enlarge
Page 2

Notes, Cautions, and Warnings

your computer.

instructions are not followed.

injury, or death.

Information in this publication is subject to change without notice. © 2009-2010 Dell Inc. All rights reserved.

Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.

Trademarks used in this text: Dell, the DELL logo, PowerEdge, and OpenManage are trademarks of Dell Inc.; Microsoft, Windows and Windows Server are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries; Novell, NetWare, and SUSE are registered trademarks of Novell, Inc. in the United States and other countries; Red Hat and Red Hat Enterprise Linux are registered trademarks of Red Hat Inc.in the United States and other countries.

Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.

UCS-71, UCS-70, and UCSM-70

July 2010 Rev. A01

Page 3 of the Dell PowerEdge H200 user manual — Table of contents
Page 3 · click to enlarge
Page 3

Table of contents

CAUTION: Safety Instructionsp.9SAFETY: Generalp.9SAFETY: When Working Inside Your Systemp.10Protecting Against Electrostatic Dischargep.10SAFETY: Battery Disposalp.11Overviewp.13Operating System Supportp.14About RAIDp.15RAID Levelsp.15RAID Terminologyp.15RAID 0p.15RAID 1p.16RAID 10p.17PERC H200 and 6Gbps SAS HBA Featuresp.19LED Port Activity Feature for 6Gbps SAS HBA Onlyp.23Physical Disk Cache Policyp.24Unsupported Drivesp.24Hardware Installationp.25Installing the PERC H200 and 6Gbps SAS HBA Cardsp.25Installing the PERC H200 Modular Cardp.29Driver Installationp.31Installing the Windows Driverp.32Creating the Driver Mediap.32Pre-Installation Requirementsp.32Installing the Driver During a Windows Server 2003 Operating System Installationp.33Installing the Driver During a Windows Server 2008 or Windows Server 2008 R2 Installationp.34Installing a Windows Server 2003, Windows Server 2008 or Windows Server 2008 R2 Driver for a New RAID Controllerp.35Updating the Windows Driverp.36Installing Linux Driverp.37Creating a DUDp.37Creating a DUD Using DKMSp.39Installing Red Hat Enterprise Linux Operating System Using the DUDp.39Installing SUSE Linux Enterprise Server Using the DUDp.40Installing the RPM Package With DKMS Supportp.41Upgrading the Kernelp.41PERC H200 and 6Gbps SAS HBA BIOSp.43POST Messagesp.43BIOS Fault Code Messagesp.43Booting With Multiple Controllersp.44Configuration Utilityp.44Starting the Configuration Utilityp.44Functions Performedp.44RAID Configuration and Management Screensp.46Select New Volume Typep.47Create New Volumep.47View Volumep.50Manage Volumep.50Exit Screenp.51Performing Configuration Tasksp.51Creating a RAID 0 Virtual Diskp.52Creating a RAID 1 Virtual Diskp.53Creating a RAID 10 Virtual Diskp.54Viewing Virtual Disk Propertiesp.56Activating a Virtual Diskp.56Migrating and Activating a Virtual Diskp.57Deleting a Virtual Diskp.57Hot Spare Failoverp.58Replacing and Rebuilding a Degraded Virtual Diskp.58Assigning a Preferred Boot Devicep.59Troubleshootingp.61BIOS Boot Orderp.61Background Activitiesp.61General Issuesp.62Physical Disk Related Issuesp.63Configuration Utility Error Messagesp.64BIOS Error Messagesp.65Updating the Firmwarep.71Firmware Package Update Utilityp.71Getting Helpp.73Technical Support and Customer Servicep.73Online Servicesp.74Automated Order-Status Servicep.75Dell Enterprise Trainingp.75Problems With Your Orderp.75Product Informationp.75Returning Items for Warranty Repair or Creditp.76Before You Callp.76Regulatory Noticesp.77Corporate Contact Details (Taiwan Only)p.79Glossaryp.81Indexp.91
Page 4 of the Dell PowerEdge H200 user manual
Page 4 · click to enlarge
Page 4

4 Hardware Installation 25

Installing the PERC H200 and 6Gbps SAS HBA Cards 25

Installing the PERC H200 Modular Card 28

5 Driver Installation 31

Installing the Windows Driver 32

Creating the Driver Media 32

Pre-Installation Requirements 32

Installing the Driver During a Windows Server 2003 Operating System Installation 33

Installing the Driver During a Windows Server 2008 or Windows Server 2008 R2 Installation . . . 34

Installing a Windows Server 2003, Windows Server 2008 or Windows Server 2008 R2 Driver for a New RAID Controller 35

Updating the Windows Driver 36

Installing Linux Driver 37

Creating a DUD 37

Creating a DUD Using DKMS 39

Installing Red Hat Enterprise Linux Operating System Using the DUD 39

Installing SUSE Linux Enterprise Server Using the DUD 40

Installing the RPM Package With DKMS Support 40

Upgrading the Kernel 41

4 Contents

Page 5 of the Dell PowerEdge H200 user manual — Table of contents
Page 5 · click to enlarge
Page 5

Table of contents

CAUTION: Safety Instructionsp.9SAFETY: Generalp.9SAFETY: When Working Inside Your Systemp.10Protecting Against Electrostatic Dischargep.10SAFETY: Battery Disposalp.11Overviewp.13Operating System Supportp.14About RAIDp.15RAID Levelsp.15RAID Terminologyp.15RAID 0p.15RAID 1p.16RAID 10p.17PERC H200 and 6Gbps SAS HBA Featuresp.19LED Port Activity Feature for 6Gbps SAS HBA Onlyp.23Physical Disk Cache Policyp.24Unsupported Drivesp.24Hardware Installationp.25Installing the PERC H200 and 6Gbps SAS HBA Cardsp.25Installing the PERC H200 Modular Cardp.29Driver Installationp.31Installing the Windows Driverp.32Creating the Driver Mediap.32Pre-Installation Requirementsp.32Installing the Driver During a Windows Server 2003 Operating System Installationp.33Installing the Driver During a Windows Server 2008 or Windows Server 2008 R2 Installationp.34Installing a Windows Server 2003, Windows Server 2008 or Windows Server 2008 R2 Driver for a New RAID Controllerp.35Updating the Windows Driverp.36Installing Linux Driverp.37Creating a DUDp.37Creating a DUD Using DKMSp.39Installing Red Hat Enterprise Linux Operating System Using the DUDp.39Installing SUSE Linux Enterprise Server Using the DUDp.40Installing the RPM Package With DKMS Supportp.41Upgrading the Kernelp.41PERC H200 and 6Gbps SAS HBA BIOSp.43POST Messagesp.43BIOS Fault Code Messagesp.43Booting With Multiple Controllersp.44Configuration Utilityp.44Starting the Configuration Utilityp.44Functions Performedp.44RAID Configuration and Management Screensp.46Select New Volume Typep.47Create New Volumep.47View Volumep.50Manage Volumep.50Exit Screenp.51Performing Configuration Tasksp.51Creating a RAID 0 Virtual Diskp.52Creating a RAID 1 Virtual Diskp.53Creating a RAID 10 Virtual Diskp.54Viewing Virtual Disk Propertiesp.56Activating a Virtual Diskp.56Migrating and Activating a Virtual Diskp.57Deleting a Virtual Diskp.57Hot Spare Failoverp.58Replacing and Rebuilding a Degraded Virtual Diskp.58Assigning a Preferred Boot Devicep.59Troubleshootingp.61BIOS Boot Orderp.61Background Activitiesp.61General Issuesp.62Physical Disk Related Issuesp.63Configuration Utility Error Messagesp.64BIOS Error Messagesp.65Updating the Firmwarep.71Firmware Package Update Utilityp.71Getting Helpp.73Technical Support and Customer Servicep.73Online Servicesp.74Automated Order-Status Servicep.75Dell Enterprise Trainingp.75Problems With Your Orderp.75Product Informationp.75Returning Items for Warranty Repair or Creditp.76Before You Callp.76Regulatory Noticesp.77Corporate Contact Details (Taiwan Only)p.79Glossaryp.81Indexp.91
Page 6 of the Dell PowerEdge H200 user manual — Table of contents
Page 6 · click to enlarge
Page 6

Table of contents

CAUTION: Safety Instructionsp.9SAFETY: Generalp.9SAFETY: When Working Inside Your Systemp.10Protecting Against Electrostatic Dischargep.10SAFETY: Battery Disposalp.11Overviewp.13Operating System Supportp.14About RAIDp.15RAID Levelsp.15RAID Terminologyp.15RAID 0p.15RAID 1p.16RAID 10p.17PERC H200 and 6Gbps SAS HBA Featuresp.19LED Port Activity Feature for 6Gbps SAS HBA Onlyp.23Physical Disk Cache Policyp.24Unsupported Drivesp.24Hardware Installationp.25Installing the PERC H200 and 6Gbps SAS HBA Cardsp.25Installing the PERC H200 Modular Cardp.29Driver Installationp.31Installing the Windows Driverp.32Creating the Driver Mediap.32Pre-Installation Requirementsp.32Installing the Driver During a Windows Server 2003 Operating System Installationp.33Installing the Driver During a Windows Server 2008 or Windows Server 2008 R2 Installationp.34Installing a Windows Server 2003, Windows Server 2008 or Windows Server 2008 R2 Driver for a New RAID Controllerp.35Updating the Windows Driverp.36Installing Linux Driverp.37Creating a DUDp.37Creating a DUD Using DKMSp.39Installing Red Hat Enterprise Linux Operating System Using the DUDp.39Installing SUSE Linux Enterprise Server Using the DUDp.40Installing the RPM Package With DKMS Supportp.41Upgrading the Kernelp.41PERC H200 and 6Gbps SAS HBA BIOSp.43POST Messagesp.43BIOS Fault Code Messagesp.43Booting With Multiple Controllersp.44Configuration Utilityp.44Starting the Configuration Utilityp.44Functions Performedp.44RAID Configuration and Management Screensp.46Select New Volume Typep.47Create New Volumep.47View Volumep.50Manage Volumep.50Exit Screenp.51Performing Configuration Tasksp.51Creating a RAID 0 Virtual Diskp.52Creating a RAID 1 Virtual Diskp.53Creating a RAID 10 Virtual Diskp.54Viewing Virtual Disk Propertiesp.56Activating a Virtual Diskp.56Migrating and Activating a Virtual Diskp.57Deleting a Virtual Diskp.57Hot Spare Failoverp.58Replacing and Rebuilding a Degraded Virtual Diskp.58Assigning a Preferred Boot Devicep.59Troubleshootingp.61BIOS Boot Orderp.61Background Activitiesp.61General Issuesp.62Physical Disk Related Issuesp.63Configuration Utility Error Messagesp.64BIOS Error Messagesp.65Updating the Firmwarep.71Firmware Package Update Utilityp.71Getting Helpp.73Technical Support and Customer Servicep.73Online Servicesp.74Automated Order-Status Servicep.75Dell Enterprise Trainingp.75Problems With Your Orderp.75Product Informationp.75Returning Items for Warranty Repair or Creditp.76Before You Callp.76Regulatory Noticesp.77Corporate Contact Details (Taiwan Only)p.79Glossaryp.81Indexp.91
Page 7 of the Dell PowerEdge H200 user manual
Page 7 · click to enlarge
Page 7

C Regulatory Notices 77

D Corporate Contact Details (Taiwan Only) 79

Glossary 81

Index 91

Contents 7

Page 8 of the Dell PowerEdge H200 user manual
Page 8 · click to enlarge
Page 8

8 Contents

Page 9 of the Dell PowerEdge H200 user manual — CAUTION: Safety Instructions
Page 9 · click to enlarge
Page 9

CAUTION: Safety Instructions

Use the following safety guidelines to help ensure your own personal safety and to help protect your system and working environment from potential damage.

Replace the battery only with the same or equivalent type recommended by the manufacturer. See "SAFETY: Battery Disposal" on page 11.

and Returns, Export Regulations, Software License Agreement, Safety, Environmental and Ergonomic Instructions, Regulatory Notices, and Recycling Information, see the Safety, Environmental and Regulatory Information, End User License Agreement, and Warranty and Support Information that shipped with your system.

SAFETYGeneral
  • Observe and follow service markings. Do not service any product except as explained in your user documentation. Opening or removing covers that are marked with the triangular symbol with a lightning bolt may expose you to electrical shock. Components inside these compartments must be serviced only by a trained service technician.
  • If any of the following conditions occur, unplug the product from the electrical outlet, and replace the part or contact your trained service provider:

– The power cable, extension cable, or plug is damaged.

– An object has fallen in the product.

– The product has been exposed to water.

– The product has been dropped or damaged.

– The product does not operate correctly when you follow the operating instructions.

  • Use the product only with approved equipment.
  • Operate the product only from the type of external power source indicated on the electrical ratings label. If you are not sure of the type of power source required, consult your service provider or local power company.
  • Handle batteries carefully. Do not disassemble, crush, puncture, short external contacts, dispose of in fire or water, or expose batteries to temperatures higher than 60° Celsius (140° Fahrenheit). Do not attempt to open or service batteries; replace batteries only with batteries designated for the product.
Page 10 of the Dell PowerEdge H200 user manual — Protecting Against Electrostatic Discharge
Page 10 · click to enlarge
Page 10

SAFETY: When Working Inside Your System

Before you remove the system covers, perform the following steps in the sequence indicated.

service technicians are authorized to remove the system cover and access any of the components inside the system.

turning off the system before removing a component from the system board or disconnecting a peripheral device. 1 Turn off the system and any connected devices. 2 Disconnect your system and devices from their power sources. To reduce the potential of personal injury or shock, disconnect any telecommunication lines from the system. 3 Ground yourself by touching an unpainted metal surface on the chassis before touching anything inside the system. 4 While you work, periodically touch an unpainted metal surface on the chassis to dissipate any static electricity that might harm internal components.

In addition, take note of these safety guidelines when appropriate:

  • When you disconnect a cable, pull on its connector or on its strain-relief loop, not on the cable itself. Some cables have a connector with locking tabs. If you are disconnecting this type of cable, press in on the locking tabs before disconnecting the cable. As you pull connectors apart, keep them evenly aligned to avoid bending any connector pins. Also, when you connect a cable, make sure both connectors are correctly oriented and aligned.
  • Handle components and cards with care. Do not touch the components or contacts on a card. Hold a card by its edges or by its metal mounting bracket. Hold a component such as a microprocessor chip by its edges, not by its pins.

Protecting Against Electrostatic Discharge

Electrostatic discharge (ESD) events can harm electronic components inside your system. Under certain conditions, ESD may build up on your body or an object, such as a peripheral, and then discharge into another object, such as your system. To prevent ESD damage, you must discharge static electricity from your body before you interact with any of your system’s internal electronic components, such as a memory module. You can protect against ESD by touching a metal grounded object (such as an unpainted metal surface on your system’s I/O panel) before you interact with anything electronic. When connecting a peripheral (including handheld digital assistants) to your system, you should always ground both yourself and the peripheral before connecting it to the system. Additionally, as you work inside the system, periodically touch an I/O connector to remove any static charge your body may have accumulated.

10 CAUTIONSafety Instructions
Page 11 of the Dell PowerEdge H200 user manual — SAFETY: Battery Disposal
Page 11 · click to enlarge
Page 11

You can also take the following steps to prevent damage from electrostatic discharge:

  • When unpacking a static-sensitive component from its shipping carton, do not remove the component from the antistatic packing material until you are ready to install the component. Just before unwrapping the antistatic package, be sure to discharge static electricity from your body.
  • When transporting a sensitive component, first place it in an antistatic container or packaging.
  • Handle all electrostatic sensitive components in a static-safe area. If possible, use antistatic floor pads and work bench pads.

SAFETY: Battery Disposal

Your system may use a nickel-metal hydride (NiMH), lithium coin-cell, and/or a lithium-ion battery. The NiMH, lithium coin-cell, and lithium-ion batteries are long-life batteries, and it is possible that you will never need to replace them.

disposal agency for the address of the nearest battery deposit site.

batteries. These batteries too must be disposed of in a battery deposit site. For information about such batteries, see the documentation for the specific card or component.

Taiwan Battery Recycling Mark

Page 12 of the Dell PowerEdge H200 user manual — SAFETY: Battery Disposal
Page 12 · click to enlarge
Page 12
12 CAUTIONSafety Instructions
Page 13 of the Dell PowerEdge H200 user manual — Overview
Page 13 · click to enlarge
Page 13

Overview

The Dell™ PowerEdge™ RAID Controller (PERC) H200 and the 6Gbps SAS HBA cards are part of the third generation of the Dell Serial-Attached SCSI (SAS) RAID controllers. The PERC H200 and 6Gbps SAS HBA cards comply with the T10 SAS 2.0 specification, providing upto 6 Gb/sec throughput, and improved hardware performance.

The PERC H200 card has integrated RAID capabilities and enables support for Dell-qualified hard drives and solid-state drives (SSD). The card also enables support for internal tape drives in PowerEdge systems only. The 6Gbps SAS HBA provides support for Dell-supported external SAS tape devices.

The PERC H200 and 6Gbps SAS HBA cards are all standard half-length, half-height PCI-E cards, except for the PERC H200 Integrated Modular controller on the blade systems.

The PERC H200 and 6Gbps SAS HBA cards are supported with PCI-E x8 link width. The cards can be used on platforms with PCI-E x8 and x16 connectors, and communicates with SAS devices using 2x4 mini-SAS external connectors. The PERC H200 Integrated Modular controller supports PCI-E x4 link width only.

Key features of the PERC H200 and 6Gbps SAS HBA cards include

  • SAS 2.0 compliance, 6Gb/sec throughput
  • RAID 0, RAID 1, and RAID 10 functionality
  • Support for SSDs
  • Support for LT03 060, LT04, and LT05 tape drives
  • Support for full hardware Transport Layer Retry (TLR), to improve maximum tape throughput
  • Mini-SAS connectors
  • PCI-E 2.0 compliant to key features
  • Support for two global hotspares

Overview 13

Page 14 of the Dell PowerEdge H200 user manual — Operating System Support
Page 14 · click to enlarge
Page 14

Figure 2-1. 6Gbps SAS HBA Hardware Architecture

Dell PowerEdge H200 — Operating System Support diagram (page 14)
Fig. 1 · Operating System Support

1 2 x4 external SAS connectors 2 PCI-E connector

Operating System Support

The PERC H200 and 6Gbps SAS HBA cards support the following operating systems:

  • Microsoft ® Windows Server ® 2003 family
  • Microsoft Windows Server 2008 family, including Hyper-V Virtualization
  • Microsoft Windows Server 2008 R2
  • Red Hat ® Enterprise Linux ® version 4.7, version 4.8, and version 5.3
  • SUSE ® Linux Enterprise Server version 10 Service Pack 2 (64-bit only), version 10 Service Pack 3 (64-bit only), and version 11 (64-bit only)
  • Sun ® Solaris™10 (64-bit)
  • VMware ® ESX 4.0 Update 1

instructions, see the system documentation on the Dell Support website at support.dell.com/manuals For specific operating system service pack requirements, see the Drivers and Downloads section on the Dell Support website at support.dell.com.

14 Overview

Page 15 of the Dell PowerEdge H200 user manual — RAID 0
Page 15 · click to enlarge
Page 15

About RAID

RAID is a group of multiple independent physical disks that provide high performance or better data availability by increasing the number of drives used for saving and accessing data. A RAID disk subsystem improves I/O performance and data availability. The physical disk group appears to the host system as a single storage unit. Data throughput improves because multiple disks can be accessed simultaneously. RAID systems also improve data storage availability and fault tolerance.

  • RAID 0 uses disk striping to provide high data throughput, especially for large files in an environment that requires no data redundancy.
  • RAID 1 uses disk mirroring so that data written to one physical disk is simultaneously written to another physical disk. This is good for small databases or other applications that require small capacity, but complete data redundancy.
  • RAID 10, a combination of RAID 0 and RAID 1, uses disk striping across mirrored disks. It provides high data throughput and complete data redundancy.

a physical disk failure.

RAID Terminology

RAID 0

RAID 0 allows you to write data across multiple physical disks instead of just one physical disk. RAID 0 involves partitioning each physical disk storage space into 64 KB stripes. These stripes are interleaved in a repeated sequential manner. The part of the stripe on a single physical disk is called a stripe element.

For example, in a four-disk system using only RAID 0, segment 1 is written to disk 1, segment 2 is written to disk 2, and so on. RAID 0 enhances performance because multiple physical disks are accessed simultaneously, but it does not provide data redundancy. Figure 2-2 shows an example of RAID 0.

RAID Levels · Overview 15

Page 16 of the Dell PowerEdge H200 user manual — Table of contents
Page 16 · click to enlarge
Page 16

Table of contents

CAUTION: Safety Instructionsp.9SAFETY: Generalp.9SAFETY: When Working Inside Your Systemp.10Protecting Against Electrostatic Dischargep.10SAFETY: Battery Disposalp.11Overviewp.13Operating System Supportp.14About RAIDp.15RAID Levelsp.15RAID Terminologyp.15RAID 0p.15RAID 1p.16RAID 10p.17PERC H200 and 6Gbps SAS HBA Featuresp.19LED Port Activity Feature for 6Gbps SAS HBA Onlyp.23Physical Disk Cache Policyp.24Unsupported Drivesp.24Hardware Installationp.25Installing the PERC H200 and 6Gbps SAS HBA Cardsp.25Installing the PERC H200 Modular Cardp.29Driver Installationp.31Installing the Windows Driverp.32Creating the Driver Mediap.32Pre-Installation Requirementsp.32Installing the Driver During a Windows Server 2003 Operating System Installationp.33Installing the Driver During a Windows Server 2008 or Windows Server 2008 R2 Installationp.34Installing a Windows Server 2003, Windows Server 2008 or Windows Server 2008 R2 Driver for a New RAID Controllerp.35Updating the Windows Driverp.36Installing Linux Driverp.37Creating a DUDp.37Creating a DUD Using DKMSp.39Installing Red Hat Enterprise Linux Operating System Using the DUDp.39Installing SUSE Linux Enterprise Server Using the DUDp.40Installing the RPM Package With DKMS Supportp.41Upgrading the Kernelp.41PERC H200 and 6Gbps SAS HBA BIOSp.43POST Messagesp.43BIOS Fault Code Messagesp.43Booting With Multiple Controllersp.44Configuration Utilityp.44Starting the Configuration Utilityp.44Functions Performedp.44RAID Configuration and Management Screensp.46Select New Volume Typep.47Create New Volumep.47View Volumep.50Manage Volumep.50Exit Screenp.51Performing Configuration Tasksp.51Creating a RAID 0 Virtual Diskp.52Creating a RAID 1 Virtual Diskp.53Creating a RAID 10 Virtual Diskp.54Viewing Virtual Disk Propertiesp.56Activating a Virtual Diskp.56Migrating and Activating a Virtual Diskp.57Deleting a Virtual Diskp.57Hot Spare Failoverp.58Replacing and Rebuilding a Degraded Virtual Diskp.58Assigning a Preferred Boot Devicep.59Troubleshootingp.61BIOS Boot Orderp.61Background Activitiesp.61General Issuesp.62Physical Disk Related Issuesp.63Configuration Utility Error Messagesp.64BIOS Error Messagesp.65Updating the Firmwarep.71Firmware Package Update Utilityp.71Getting Helpp.73Technical Support and Customer Servicep.73Online Servicesp.74Automated Order-Status Servicep.75Dell Enterprise Trainingp.75Problems With Your Orderp.75Product Informationp.75Returning Items for Warranty Repair or Creditp.76Before You Callp.76Regulatory Noticesp.77Corporate Contact Details (Taiwan Only)p.79Glossaryp.81Indexp.91
Page 17 of the Dell PowerEdge H200 user manual — RAID 10
Page 17 · click to enlarge
Page 17

RAID 10

RAID 10 requires two or more mirrored sets working together. Multiple RAID 1 sets are combined to form a single array. Data is striped across all mirrored drives. Since each drive is mirrored in RAID 10, no delay is encountered because no parity calculation is done. This RAID strategy can tolerate the loss of multiple drives as long as two drives of the same mirrored pair do not fail. RAID 10 volumes provide high data throughput and complete data redundancy.

Figure 2-4. Example of RAID 10

stripe element 1 stripe element 3 stripe element 5

stripe element 1 duplicated stripe element 3 duplicated stripe element 5 duplicated stripe element 7 stripe element 7 duplicated

stripe element 2 stripe element 4 stripe element 6

stripe element 2 duplicated stripe element 4 duplicated stripe element 6 duplicated stripe element 8 stripe element 8 duplicated

Overview 17

Page 18 of the Dell PowerEdge H200 user manual — RAID 10
Page 18 · click to enlarge
Page 18

18 Overview

Page 19 of the Dell PowerEdge H200 user manual — LSI SAS 2008
Page 19 · click to enlarge
Page 19

PERC H200 and 6Gbps SAS HBA Features

This section provides the specifications of the Dell™ PowerEdge™ RAID Controller (PERC) H200 and 6Gbps SAS HBA cards.

Table 3-1 compares the specifications of the PERC H200 Adapter and PERC H200 Integrated and PERC H200 Modular cards.

Table 3-1. Specifications of PERC H200

Specification PERC H200 Adapter PERC H200 Integrated PERC H200 Modular

SAS technology Yes Yes Yes

Support for x4 or x8 PCI-E Host Interface

Half-Height, Half-Length PCI Adapter

Half-Height, Half-Length PCI Adapter

LSI SAS 2008

LSI SAS 2008

LSI SAS 2008

Core Speed533 MHz
Core Speed533 MHz
Core Speed533 MHz

+12V, +3.3V, +3.3Vaux

+12V, +3.3V, +3.3Vaux

+12V, +3.3V, +3.3Vaux

Communication to the system

PCI-E lanes PCI-E lanes System dependent

Communication to end devices

SAS Links SAS Links SAS Links

SAS Connectors 2x4 internal 2x4 internal SAS connectivity routed through PCI-E connector

Lead Free Yes Yes Yes

PERC H200 and 6Gbps SAS HBA Features 19

Show 5 more labels / short text on this page
Yes Yes Yes · Form Factor · Custom · I/O Controller (IOC) · Operating voltage requirements
Page 20 of the Dell PowerEdge H200 user manual — RAID 0, RAID 1, RAID 10
Page 20 · click to enlarge
Page 20

Table 3-1. Specifications of PERC H200 (continued)

Specification PERC H200 Adapter PERC H200 Integrated PERC H200 Modular

Microsoft® Windows Server® 2003 family, Microsoft Windows Server 2008 family, Windows Server 2008 R2, Red Hat® Enterprise Linux® version 4 Update 7 and later, version 5 Update 3 and later, SUSE® Linux Enterprise Server version 10 Service Pack 2 and later (64-bit only), and version 11 Gold and later (64-bit only).

Dell-compliant SAS and SATA compatibility

Dell supported direct connected end devices

SMART error support through management applications

RAID 0, RAID 1, RAID 10

RAID 0, RAID 1, RAID 10

RAID 0, RAID 1, RAID 10

Maximum number of virtual disks

Dell OpenManage™ Storage Services

Support for internal tape drive

Support for Global Hotspare

Maximum number of physical disks

20 PERC H200 and 6Gbps SAS HBA Features

Show 15 more labels / short text on this page
Supported operating systems · Yes Yes Yes · Dell-compliant physical disks · Dell-compliant physical disks · Dell-compliant physical disks · Yes Yes Yes · Backplane supported systems · Yes Yes Yes · Hardware-based RAID · Storage management software · OpenManage Storage Services · OpenManage Storage Services · Yes No No · Yes Yes Yes · 16 16 4
Page 21 of the Dell PowerEdge H200 user manual — PERC H200 and 6Gbps SAS HBA Features
Page 21 · click to enlarge
Page 21

Table 3-1. Specifications of PERC H200 (continued)

Specification PERC H200 Adapter PERC H200 Integrated PERC H200 Modular

Maximum number of physical disks configured in a single RAID disk

Maximum number of configured disks (including hot spares)

Maximum number of Hotspares

Table 3-2 lists the specifications of the 6Gbps SAS HBA.

Table 3-2. Specifications of 6Gbps SAS HBA

Specification 6Gbps SAS HBA

Support for x8, or x8 Full-Size PCI Express Host Interface

Form Factor Half-Size, Half-Length PCI Adapter

I/O controller (IOC) LSI SAS 2008

Core Speed 533 MHz

Operating voltage requirements +12V, +3.3V, +3.3Vaux

Communication to the system PCI-E lanes

Communication to end devices SAS Links

PERC H200 and 6Gbps SAS HBA Features 21

Show 7 more labels / short text on this page
10 10 4 · 14 14 4 · 6Gbps Expander Support · Yes Yes No · SAS technology Yes · Yes · Connectors 2x4 Mini-SAS
Page 22 of the Dell PowerEdge H200 user manual — PERC H200 and 6Gbps SAS HBA Features
Page 22 · click to enlarge
Page 22

Table 3-2. Specifications of 6Gbps SAS HBA

Specification 6Gbps SAS HBA

Supported operating systems Microsoft Windows Server 2003 family, Microsoft Windows Server 2008 family, Windows Server 2008 R2, Red Hat Enterprise Linux

version 4 Update 7 and later, version 5 Update 3 and later, SUSE Linux Enterprise Server version 10 Service Pack 2 and later (64-bit only), and version 11 Gold and later (64-bit only).

Dell-compliant SAS and SATA compatibility

Dell-supported direct connected end devices

Dell-supported external tape devices.

Hot add or Hot remove of end devices

Support for external tape drive Yes

Port activity or status LEDs Yes

22 PERC H200 and 6Gbps SAS HBA Features

Show 4 more labels / short text on this page
Lead Free Yes · Yes · Yes · Hardware-based RAID No
Page 23 of the Dell PowerEdge H200 user manual — LED Port Activity Feature for 6Gbps SAS HBA Only
Page 23 · click to enlarge
Page 23

LED Port Activity Feature for 6Gbps SAS HBA Only

The 6Gbps SAS HBA controllers are equipped with port activity or status LEDs. The LEDs enable you to quickly determine the status of an external SAS port. Each x4 connector has its own set of LEDs.

Table 3-3 describes the color of the LEDs and corresponding SAS port state.

Table 3-3. x4 Connector LEDs Description

LED Color SAS Port State

Off It means any one of the following:

  • Power is off.
  • Port has been reset.
  • All links in the port are either disconnected or the cable is disconnected.

Green All links in the port are connected and functional.

Amber One or more links in the port is not connected. This is only applicable in a wide port configuration.

PERC H200 and 6Gbps SAS HBA Features 23

Page 24 of the Dell PowerEdge H200 user manual — Physical Disk Cache Policy
Page 24 · click to enlarge
Page 24

Physical Disk Cache Policy

The default cache policy on a physical disk is Enabled in SATA drives and Disabled on SAS drives. When physical disk caching is Enabled, disk I/O performance is improved, but a power outage or equipment failure might result in data loss or corruption.

production systems.

On a PERC H200 card, caching is forced to be disabled for all physical disks configured into a virtual disk, regardless of the drive type and default drive settings.

Drives that are not certified by Dell are reported in the BIOS Configuration Utility, also known as .

To view unsupported drives:

1 In the BIOS Configuration Utility, navigate to the SAS Topology screen.

2 Select the unsupported drive and press to view the Device Properties screen.

The drive is marked as Uncertified in the Device Properties screen.

Drives that are not certified by Dell are not blocked and you can use them at your own risk.

24 PERC H200 and 6Gbps SAS HBA Features

Unsupported Drives

Page 25 of the Dell PowerEdge H200 user manual — Hardware Installation
Page 25 · click to enlarge
Page 25

Hardware Installation

This chapter describes how to install the Dell™ PowerEdge™ RAID Controller (PERC) H200 and 6Gbps SAS HBA cards. Installing the PERC H200 and 6Gbps SAS HBA Cards

You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1 Unpack the PERC H200 card or 6Gbps SAS HBA and check for damage.

2 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. See your system’s Hardware Owner’s Manual or the User’s Guide for more information on power supplies.

3 Disconnect the system from the network and remove the cover of the system. See your system’s Hardware Owner’s Manual or the User’s Guide for more information on opening the system.

4 Select an appropriate PCI-E slot. If replacing a PERC H200 Adapter or 6Gbps SAS HBA, remove the blank filler bracket on the back of the system aligned with the PCI-E slot you have selected.

system’s Hardware Owner’s Manual.

5 Align the controller to the PCI-E slot you have selected.

Hardware Installation 25

Page 26 of the Dell PowerEdge H200 user manual — Hardware Installation
Page 26 · click to enlarge
Page 26

6 Insert the controller gently, but firmly, until the controller is firmly seated in the PCI-E slot. See Figure 4-1.

in this section are common for the H200 Integrated, H200 Adapter and 6Gbps SAS HBA.

details, see the system’s Hardware Owner's Manual on the Dell Support website at support.dell.com.

Figure 4-1. Installing a 6Gbps SAS HBA

Dell PowerEdge H200 — Hardware Installation diagram (page 26)
Fig. 2 · Hardware Installation

1 bracket screw 2 6Gbps SAS HBA

3 PCI-E slot · 26 Hardware Installation

Page 27 of the Dell PowerEdge H200 user manual — Hardware Installation
Page 27 · click to enlarge
Page 27

7 Tighten the bracket screw, if any, or use the system’s retention clips to secure the controller to the system’s chassis.

8 For a PERC H200 card, connect the cables from the end devices or the backplane of the system to the controller. See Figure 4-2.

Figure 4-2. Connecting the Cable for PERC H200

Dell PowerEdge H200 — Hardware Installation diagram (page 27)
Fig. 3 · Hardware Installation

1 SAS x4 internal connector 2 cable

3 PERC H200 Card

9 For the 6Gbps SAS HBA controller, connect the cable from the external enclosure to the adapter. See Figure 4-3.

external connectors.

Hardware Installation 27

Page 28 of the Dell PowerEdge H200 user manual — Hardware Installation
Page 28 · click to enlarge
Page 28

Figure 4-3. Connecting the Cable for 6Gbps SAS HBA

Dell PowerEdge H200 — Hardware Installation diagram (page 28)
Fig. 4 · Hardware Installation

1 6Gbps SAS HBA 2 Cable from the external enclosure

10 Replace the cover of the system. See your system’s Hardware Owner’s Manual or the User’s Guide for more information on closing the system.

11 Reconnect the power cable(s) and network cables, and then turn on the system.

same PERC H200 card.

see your system’s Hardware Owner’s Manual on the Dell Support website at support.dell.com/manuals

or a tape drive is not supported.

28 Hardware Installation

Page 29 of the Dell PowerEdge H200 user manual — Installing the PERC H200 Modular Card
Page 29 · click to enlarge
Page 29

Installing the PERC H200 Modular Card

see your system’s Hardware Owner’s Manual or the User’s Guide from the Dell Support website at support.dell.com.

The storage controller card is located below the hard drive bays of the Dell Blade system.

To remove the storage controller card:

1 Remove the Dell Blade system from the Blade system chassis.

2 Remove the system cover of the Blade system.

3 Remove the system board and place it on a stable and flat surface.

4 Open the release lever to disconnect the storage controller card edge connector from the system board connector as illustrated in Figure 4-4.

5 Lift the storage controller card straight up from the system board as illustrated in Figure 4-4.

Figure 4-4. Removing and Installing the Storage Controller Card

Dell PowerEdge H200 — Installing the PERC H200 Modular Card diagram (page 29)
Fig. 5 · Installing the PERC H200 Modular Card

1 storage controller card 2 release lever

Hardware Installation 29

Page 30 of the Dell PowerEdge H200 user manual — Installing the PERC H200 Modular Card
Page 30 · click to enlarge
Page 30

To install your new storage controller card:

1 Unpack the new storage controller card and check for damage.

2 Place the storage controller card onto the system board. Align the storage controller card such that the tabs on the system board tray fit through the notches on the edges of the storage controller card.

3 Slide the storage controller card towards the connector on the system board until the storage controller clicks in place.

4 Reinstall the system board. For more information on reinstalling the system board, see your system’s Hardware Owner’s Manual or the User’s Guide.

5 Close the top cover of the Blade system. For more information on closing the top cover of the Modular Blade system, see your system’s Hardware Owner’s Manual or the User’s Guide.

6 Reinstall the Blade system in the Blade system chassis. For more information on reinstalling the Blade system in the Blade system chassis, see your system’s Hardware Owner’s Manual or the User’s Guide.

documentation located at the Dell Support website at support.dell.com.

30 Hardware Installation

Page 31 of the Dell PowerEdge H200 user manual — Driver Installation
Page 31 · click to enlarge
Page 31

Driver Installation

The Dell™ PowerEdge™ RAID Controller (PERC) H200 and 6Gbps SAS HBA cards require software drivers to operate with Microsoft® Windows®, Red Hat® Enterprise Linux®, and SUSE® Linux operating systems.

This section contains the procedures for installing the drivers for the following operating systems:

  • Microsoft Windows Server 2003 Server family
  • Microsoft Windows Server 2008 Server family
  • Windows Server 2008 R2
  • Red Hat Linux version 4 Update 7 and later, and version 5 Update 3 and later
  • SUSE Linux Enterprise Server version 10 Service Pack 2 and later (64-bit only), and version 11 Gold and later (64-bit only)

The three methods for installing a driver that are discussed in this chapter are:

  • During operating system installation
  • After adding a new PERC H200 or 6Gbps SAS HBA controller on an existing operating system
  • Updating existing drivers

for the PERC H200 card. The driver is automatically installed. For driver updates, see the Dell Support website at support.dell.com.

is supported only when the virtual disk is in an optimal state.

section, check the Dell Support website at support.dell.com. If a newer version exists, you can download the driver to your system.

Driver Installation 31

Page 32 of the Dell PowerEdge H200 user manual — Installing the Windows Driver
Page 32 · click to enlarge
Page 32

Installing the Windows Driver

This section documents the procedures used to install the Windows driver.

Creating the Driver Media

Perform the following steps to create the driver media:

1 From the Dell Support website at support.dell.com, browse to the download section for the system.

2 Locate and download the latest PERC H200 or 6Gbps SAS HBA card driver to the system.

3 Follow the instructions on the Dell Support website for extracting the driver to the media.

Before you install the operating system:

  • Read the Microsoft Getting Started document that ships with your operating system.
  • Ensure that your system has the latest BIOS and firmware. Ensure that the latest driver is available for the installation. If required, download the latest BIOS, firmware, and driver updates from the Dell Support website at support.<a href="http://dell.com" rel="nofollow noopener" target="_blank">dell.com</a> .
  • Create a device driver media (diskette, USB drive, CD, or DVD).

Creating the Device Driver Media

Use one of the methods described in the following sections to create the device driver media.

Downloading Drivers From the Dell Systems Service and Diagnostic Tools Media

1 Insert the Dell Systems Service and Diagnostics Tools media into a system.

The Welcome to Dell Service and Diagnostic Utilities screen is displayed.

2 Select your system model and operating system.

3 Click Continue.

Pre-Installation Requirements · 32 Driver Installation

Page 33 of the Dell PowerEdge H200 user manual — Installing the Driver During a Windows Server 2003 Operating System Installation
Page 33 · click to enlarge
Page 33

4 From the list of drivers displayed, select the driver that you require. Select the self-extracting zip file and click Run. Copy the driver to a diskette drive, CD, DVD, or USB drive. Repeat this step for all the drivers that you require.

5 During the operating system installation described in "Installing the Driver During a Windows Server 2003 Operating System Installation" on page 33 and "Installing the Driver During a Windows Server 2008 or Windows Server 2008 R2 Installation" on page 34, use the media that you created with the Load Driver option to load mass storage drivers.

Downloading Drivers From the Dell Support Website

1 Go to support.dell.com.

2 Click Drivers and Downloads.

3 Enter the service tag of your system in the Choose by Service Tag field or select your system’s model.

4 Select the System Type, Operating System, Driver Language, and Category from the drop-down list.

5 The drivers that are applicable to your selection are displayed. From the available list, download the drivers that you require to a diskette drive, USB drive, CD, or DVD.

6 During the operating system installation described in "Installing the Driver During a Windows Server 2003 Operating System Installation" on page 33 and "Installing the Driver During a Windows Server 2003 Operating System Installation" on page 33, use the media that you created with the Load Driver option to load mass storage drivers.

Installing the Driver During a Windows Server 2003 Operating System Installation

Perform the following steps to install the driver during operating system installation.

1 Boot the system using the Windows Server 2003 media.

2 When the message Press F6 if you need to install a third party SCSI or RAID driver appears, press the key immediately.

Within a few minutes, a screen appears that asks for additional controllers in the system.

Driver Installation 33

Page 34 of the Dell PowerEdge H200 user manual — Installing the Driver During a Windows Server 2008 or Windows Server 2008 R2 Installation
Page 34 · click to enlarge
Page 34

3 Press the key.

The system prompts for the driver media to be inserted.

Check the Dell Support website at support.dell.com for additional details.

4 Insert the driver media in the media drive and press .

A list of SAS controllers appears.

5 Select the right driver for the installed controller and press to load the driver.

driver that you provided is older or newer than the existing Windows driver. Press to use the driver that is on the media.

6 Press again to continue the installation process as usual.

Installing the Driver During a Windows Server 2008 or Windows Server 2008 R2 Installation

Perform the following steps to install the driver during operating system installation.

1 Boot the system using the Windows Server 2008 or the Windows Server 2008 R2 media.

2 Follow on-screen instructions until you reach the message Where do you want to install 7/2008; then select Load driver...

3 The system prompts for the media to be inserted. Insert the installation media and browse to the proper location when prompted.

4 Select the appropriate PERC H200 card from the list, click Next and continue installation as usual.

the PERC H200 card. The driver is automatically installed. For driver updates, see the Dell Support website at support.dell.com.

34 Driver Installation

Page 35 of the Dell PowerEdge H200 user manual — Installing a Windows Server 2003, Windows Server 2008 or Windows Server 2008 R2 Driver for a New RAID Controller
Page 35 · click to enlarge
Page 35

Installing a Windows Server 2003, Windows Server 2008 or Windows Server 2008 R2 Driver for a New RAID Controller

Perform the following steps to configure the driver for the RAID controller on a system that already has Windows installed:

1 Turn off the system.

2 Install the new RAID controller in the system.

3 Turn on the system.

The Windows operating system detects the new controller and displays a message to inform you.

4 The Found New Hardware Wizard screen displays the detected hardware device.

5 Click Next.

6 On the Locate device driver screen, select Search for a suitable driver for my device and click Next.

7 Make the Driver Files available and browse to the proper location from the Locate Driver Files screen.

8 Click Next.

9 The wizard detects and installs the appropriate device drivers for the new RAID controller.

10 Click Finish to complete the installation.

11 Reboot the system if Windows request to do so.

support the SAS controllers. The system automatically detects the new controller and installs the driver. Check the version of the driver installed by Windows and update if necessary.

Driver Installation 35

Page 36 of the Dell PowerEdge H200 user manual — Updating the Windows Driver
Page 36 · click to enlarge
Page 36

Updating the Windows Driver

Perform the following steps to update the Windows driver for the PERC H200 card that is already installed on your system:

you update the driver.

1 Follow the step below according to your operating system.

  • For Windows Server 2003 : Click Start → Settings → Control Panel → System .
  • For Windows Server 2008: Click Start → Settings → Control Panel → System .
  • For Windows Server 2008 R2 : Click Start → Control Panel → System and Security → System
  • The System Properties screen is displayed.

2 For Windows Server 2003,click on the Hardware tab. For Windows Server 2008 and Windows Server 2008 R2, go to step 3.

3 Click Device Manager.

The Device Manager screen is displayed.

Explorer, right-click on My Computer and select Manage. The Computer Management screen is displayed. Select Device Manager in the left panel.

4 Double-click on SCSI and RAID Controllers.

5 Double-click the RAID controller for which you want to update the driver.

6 Click the Driver tab and click Update Driver.

The Upgrade Device Driver Wizard screen is displayed.

7 Make the driver files available with the USB key, or other media.

8 Select Install from a list or specific location.

9 Click Next.

36 Driver Installation

Page 37 of the Dell PowerEdge H200 user manual — Installing Linux Driver
Page 37 · click to enlarge
Page 37

10 Follow the steps in the wizard and browse to the location of the driver files.

11 Select the .inf file from the USB key or other media.

12 Click Next and continue the installation steps in the Wizard.

13 Click Finish to exit the wizard and reboot the system for the changes to take place.

Installing Linux Driver

Use the procedures in this section to install the driver for Linux. The driver is updated frequently. To ensure that you have the current version of the driver, download the updated Linux driver from the Dell Support website at support.dell.com.

system releases in which the native (in-box) driver is insufficient for installation. In the event that an operating system is being installed with a corresponding DUD image, follow the instructions below. If not, proceed with using the native device driver and then skip to "Installing the RPM Package With DKMS Support" on page 41.

Enterprise Server 11 use the mpt2sas driver, whereas Red Hat Enterprise Linux 4 uses the mpt2sasbtm driver. Examples in this section refer to the mpt2sas driver only. For Red Hat Enterprise Linux 4, replace mpt2sas with mpt2sasbtm.

Before beginning the installation, copy the drivers from the Service and Diagnostic Utilities media or download the appropriate driver for Linux from the Dell Support website at support.dell.com. This file includes Red Hat Package Managers (RPMs) and driver update disk files. The package also contains the Dynamic Kernel Module Support (DKMS) Red Hat Package Manager (RPM) file, source code, and release notes.

For more information on DKMS, see the Dell Support website at support.dell.com.

Creating a DUD · Driver Installation 37

Page 38 of the Dell PowerEdge H200 user manual — Installing Linux Driver
Page 38 · click to enlarge
Page 38

The package is a gzipped tar file. After downloading the package to a Linux system, perform the following steps:

1 Unzip the package using gunzip.

2 Untar the file using tar -xvf.

The DUD image can be transferred to a USB flash key, system floppy disk slot, or USB floppy device depending upon the availability of the media type and the operating system.

  • USB key method : Transfer the appropriate .img file to a USB key
  • System floppy Fisk slot method : Use the dd command to create a DUD. Use the appropriate image for the purpose.

a Insert a floppy disk into the system floppy disk slot.

b At a terminal prompt, type the following: # dd if= of=/dev/fd0

  • USB floppy device method : Use the dd command to create a driver update disk. Use the appropriate image for the purpose.

a Put a floppy disk into a USB floppy device and plug the device into a USB slot of the system under test. Use dmesg to find out to which device this USB floppy is enumerated (for example, sdb, sdc, etc).

b Transfer the driver image to the floppy: # dd if= of=/dev/sdx

program dcopynt.

3 Use the diskette for operating system installation. For Red Hat Enterprise Linux, see "Installing Red Hat Enterprise Linux Operating System Using the DUD" on page 39. For SUSE Linux Enterprise Server, see "Installing SUSE Linux Enterprise Server Using the DUD" on page 40.

38 Driver Installation

Page 39 of the Dell PowerEdge H200 user manual — Creating a DUD Using DKMS
Page 39 · click to enlarge
Page 39

Creating a DUD Using DKMS

Perform the following steps to create the DUD using the DKMS tool.

1 Install the DKMS-enabled mpt2sas driver rpm package.

2 Type the following command in any directory: dkms mkdriverdisk -m mpt2sas -v -k -d

Server diskettes and redhat for RHEL diskettes.

This starts the process to create the mpt2sas DUD image. After the DUD image has been built, you can find it in the DKMS tree for the mpt2sas driver. See the output of the dkms mkdriverdisk command for the exact path.

Installing Red Hat Enterprise Linux Operating System Using the DUD

Perform the following steps to install Red Hat Enterprise Linux (versions 4 and 5) and the appropriate driver.

1 Boot normally from the Red Hat Enterprise Linux installation media.

2 At the command prompt, type: linux expert dd

3 When the install prompts for additional drivers, insert the diskette or USB key and press .

4 For information about creating a driver diskette, see "Creating a DUD" on page 37.

5 Complete the installation as directed by the installation program.

Driver Installation 39

Page 40 of the Dell PowerEdge H200 user manual — Installing SUSE Linux Enterprise Server Using the DUD
Page 40 · click to enlarge
Page 40

Installing SUSE Linux Enterprise Server Using the DUD

page 37.

To install SUSE Linux Enterprise Server using the DUD:

1 Insert the appropriate SUSE Linux Enterprise Server Service Pack media in the system.

2 For SLES 10, select for the DUD. For SLES 11, select .

The system displays three options: Yes, No, and File.

Choose Yes to install the driver.

3 Select Installation from the menu.

4 Press to load the Linux kernel.

5 At the prompt Please insert the driver update floppy, click OK.

The system selects the driver from the diskette and installs it.

The system displays the message DRIVER UPDATE ADDED with the description of the driver module.

6 Click OK.

If you want to install from another driver update medium, continue with the following steps.

7 The system displays the message PLEASE CHOOSE DRIVER UPDATE MEDIUM.

8 Select the appropriate driver update medium.

The system selects the driver from the disk and installs it.

40 Driver Installation

Page 41 of the Dell PowerEdge H200 user manual — Installing the RPM Package With DKMS Support
Page 41 · click to enlarge
Page 41

Installing the RPM Package With DKMS Support

Perform the following steps to install the RPM package with DKMS support:

1 Uncompress the gzipped tarball driver release package.

2 Install the DKMS package using the command: rpm -ihv dkms- .noarch.rpm

3 Install the driver package using the command: rpm -ihv mpt2sas- .noarch.rpm

package.

4 If the previous device driver is in use, you must reboot the system for the updated driver to take effect.

5 Verify that the driver has been loaded with these system commands: modinfo mpt2sas and dkms status.

When upgrading to a new kernel, you must reinstall the DKMS-enabled driver packages. Perform the following steps to update or install the driver for the new kernel:

1 In a terminal window, type the following: #dkms build -m -v - k

#dkms install -m -v -k

2 To check whether the driver is successfully installed in the new kernel, type: dkms status

You see a message similar to the following one: , , : installed

3 If the previous device driver is in use, you must reboot the system for the updated driver to take effect.

Upgrading the Kernel · Driver Installation 41

Page 42 of the Dell PowerEdge H200 user manual — Installing the RPM Package With DKMS Support
Page 42 · click to enlarge
Page 42

42 Driver Installation

Page 43 of the Dell PowerEdge H200 user manual — POST Messages
Page 43 · click to enlarge
Page 43

PERC H200 and 6Gbps SAS HBA BIOS

The BIOS of the Dell™ PowerEdge™ RAID Controller (PERC) H200 and 6Gbps SAS HBA cards have the following features:

  • Support for multiple SAS controllers
  • RAID configuration tool (applicable to the PERC H200 card only)
  • Read-only memory (ROM) BIOS recovery image
  • POST status error messaging
  • POST accessible, text-based configuration utility (<Ctrl><C>)
  • Boot Device Selection (applicable to the PERC H200 card only)

POST Messages

During POST, the BIOS displays messages that provide the status and identification information of the PERC H200 card, and also displays errors detected during the POST process.

  • The BIOS POST identification banner prints the BIOS identification, copyright information, and the controller version.
  • The BIOS displays the list of controllers and devices detected at initialization in a hierarchical order.
  • The BIOS also prompts you to start the Configuration Utility during the POST process.

BIOS Fault Code Messages

If an error is encountered in the BIOS during POST, the BIOS Configuration Utility forces you to acknowledge BIOS errors by halting the POST process after the error display. You must press any key to continue. The BIOS Configuration Utility allows you to choose to continue booting or stop booting if errors are encountered.

PERC H200 and 6Gbps SAS HBA BIOS 43

Page 44 of the Dell PowerEdge H200 user manual — Configuration Utility
Page 44 · click to enlarge
Page 44

Booting With Multiple Controllers

When booting a system with multiple PERC H200 and/or SAS 6 Gb HBA cards, ensure that the boot device is attached to the adapter at the lowest boot order number. Proper boot order must be specified in the controller BIOS to ensure the system boots correctly. If you add a PERC H200 or 6Gbps SAS HBA card or relocate existing controllers in the system, enter the BIOS Configuration Utility to update and verify the boot order selection. Failure to do so results in a warning message displayed at POST by the BIOS. The warning persists until the you verify the boot order in the BIOS Configuration Utility.

SAS HBA card. See the Dell Support website at support.dell.com for the latest information on booting from external devices.

Configuration Utility

Starting the Configuration Utility

1 Boot the system.

2 Press during POST when prompted. If you wait too long and the operating system logo appears, continue to wait until the operating system completes bootup. Then restart your system and try again.

The Configuration Utility menu screen is displayed.

displayed at the bottom of each screen. For additional information about the utility, see the online help.

44 PERC H200 and 6Gbps SAS HBA BIOS

Functions Performed

Page 45 of the Dell PowerEdge H200 user manual — Booting With Multiple Controllers
Page 45 · click to enlarge
Page 45

Table 6-1. Functions of the Configuration Utility

Adapter List Lists all the PERC H200 and 6Gbps SAS HBA cards in the system.

Lists static and modifiable properties applicable to all PERC H200 and 6Gbps SAS HBA cards in the system.

Main screen for the selected controller. Lists the static and modifiable properties for the selected PERC H200 and 6Gbps SAS HBA cards. Provides a menu for additional screens.

Select New Volume Type

Provides the option to view existing arrays or create new volumes.

Provides the ability to add devices to the specified new volume.

View Volume Displays the properties for the existing volume and the option to enter the Manage Volume screen.

Manage Volume Provides options for managing the current volume.

Provides the ability to add or remove global hot spares.

SAS Topology Lists the physical topology for the selected controller.

Lists the properties of physical devices attached to the selected controller.

Lists the advanced properties for the selected controller.

PERC H200 and 6Gbps SAS HBA BIOS 45

Show 7 more labels / short text on this page
Function Description · Global Properties · Adapter Properties · Create New Volume · Manage Hot Spares · Device Properties · Advanced Adapter Properties
Page 46 of the Dell PowerEdge H200 user manual — RAID Configuration and Management Screens
Page 46 · click to enlarge
Page 46

Table 6-1. Functions of the Configuration Utility (continued)

Select/Deselect as Boot Device

Provides the ability to select or deselect a Boot Device.

Verify Provides the ability to verify all sectors on the device and to reassign defective Logical Block addresses (LBAs).

Provides the ability to run a consistency check on an optimal volume.

Delete Provides the ability to delete the selected volume.

Activate Volume Provides the ability to import a foreign volume.

of each screen. Online help is also available in the utility.

RAID Configuration and Management Screens

RAID configuration and management involves many GUIs. You can access the GUIs by selecting RAID Properties on the Adapter Properties screen.

The screens in the RAID configuration and management properties area are:

  • "Select New Volume Type" on page 47
  • "Create New Volume" on page 47
  • "View Volume" on page 50
  • "Manage Volume " on page 50

You are prompted to create a RAID volume, if no RAID volumes are currently configured.

Select View Existing volume to manage the volume (s), or select the appropriate option to configure a new volume, if at least one RAID volume is currently configured.

46 PERC H200 and 6Gbps SAS HBA BIOS

Function Description · Consistency Check

Page 47 of the Dell PowerEdge H200 user manual — Select New Volume Type
Page 47 · click to enlarge
Page 47

Select New Volume Type

The three options for creating a new volume are:

  • Create RAID 1 Volume
  • Create RAID 10 Volume
  • Create RAID 0 Volume

Additional information about the disk type options is displayed on the screen.

The Create New Volume screen allows you to select disks for a new volume.

1 Press to create the volume once the volume is configured.

2 Save the changes when prompted to do so.

After the volume is created, the utility returns to the Adapter Properties screen. See the table below for the volume properties description.

configurations. Table 6-2. Volume Field Descriptions

Number of current volume out of total arrays configured

Identifier text for the current volume

Type of volume (R0, R1 or R10)

Size of the volume

NOTE: To facilitate coercion on new larger disk drives, the disk size must be coerced down with a factor of 128 MB. Additionally, to comply with the latest Disk Data Format standard, 512 MB of space must be reserved for RAID metadata on the drive. This results in several hundred MB of space being removed from the usable size of an volume when it is created.

PERC H200 and 6Gbps SAS HBA BIOS 47

Show 6 more labels / short text on this page
Create New Volume · Field Description · Volume Number · Volume Identifier · Volume Type · Volume Size (GB)
Page 48 of the Dell PowerEdge H200 user manual — Select New Volume Type
Page 48 · click to enlarge
Page 48

Table 6-2. Volume Field Descriptions (continued)

Status of the current volume

The status definitions are given as:

Optimal—All members of the volume are online and ready.

Degraded—One or more members of a RAID 1 or RAID 10 volume have failed or are offline. The volume can be returned to the Optimal state by replacing the failed or offline member.

Disabled—The volume is disabled

Quiesced—The volume is quiesced

Resync—The volume is resynchronizing

Failed—The volume has failed

PermDegraded—The volume is permanently degraded. This state indicates that the failure threshold on the primary member was reached while no secondary was available for correction. The data on the volume may be accessible, but the volume cannot be returned to the optimal state.

Inactive—The imported volume is inactive. The volume must be activated before it can be accessed.

Initializing—The array is undergoing Background Initialization

BGI Pending—The array is queued up for a Background Initialization

Checking—The array is queued up for a Consistency Check

Slot number in which the specified device sits

Identifier text for the specified device

Specifies whether or not the disk is part of a RAID volume (Yes or No). This field is inactive out under the following conditions:

  • The disk does not meet the minimum requirements for use in a RAID volume.
  • The disk is not large enough to mirror existing data on the primary physical disk.
  • The disk is a part of another volume.

48 PERC H200 and 6Gbps SAS HBA BIOS

Show 5 more labels / short text on this page
Field Description · Volume Status · Slot Number · Device Identifier · RAID Disk
Page 49 of the Dell PowerEdge H200 user manual — Select New Volume Type
Page 49 · click to enlarge
Page 49

Table 6-2. Volume Field Descriptions (continued)

Hot Spare Specifies whether or not the disk is a hotspare

Ok - Disk is online and fully functional.

Missing - Disk is not detected.

Failed - Disk is not accessible or has reported a failure.

Initing - Disk is initializing.

CfgOffln - Disk is offline at host's request.

UserFail - Disk is marked failed at host's request.

Offline - Disk is offline for some other reason.

Inactive - Disk has been set to inactive.

Not Syncd - Data on disk is not synchronized with the rest of the volume.

Primary - Disk is the primary disk for a 2 disk mirror and is OK.

Secondary - Disk is the secondary disk for a 2 disk mirror and is OK.

Wrg Type - Device is not compatible for use as part of a RAID volume.

Too Small - Disk is too small to mirror existing data.

Max Dsks - Maximum # of disks allowed for this type of volume reached Maximum # of total IR disks on a controller reached.

No SMART - Disk doesn't support SMART and can't be used in a RAID volume.

Wrg Intfc - Device interface (SAS/SATA) differs from existing IR disks.

Indicates whether device SMART is predicting device failure.

Size (GB) Actual physical size of the selected disk in the volume.

NOTE: The PERC H200 cards do support Drive Status LED operation on PowerEdge systems which include drive status LEDs. Status LED support is only supported for drives which are configured as members of a Virtual Disk or Hot Spare. PERC H200 supported Drive Status LED states may vary from those supported by other hardware based RAID solutions such as the PERC H700 and H800 controllers.

PERC H200 and 6Gbps SAS HBA BIOS 49

Field Description · Drive Status · Predicted Failure

Page 50 of the Dell PowerEdge H200 user manual — View Volume
Page 50 · click to enlarge
Page 50

The View Volume screen allows you to view the current volume configuration.

Press to view the next volume. See Table 6-2 to view descriptions of each virtual disk property.

The Manage Volume screen is used to manage the current volume. The options are Manage Hotspares, Consistency Check, Activate Volume, and Delete Volume.

Table 6-3. Manage Volume Field Descriptions

Identifier The identifier of the volume

Type The RAID type of the volume

Size (GB) The coerced size of the volume

NOTE: To facilitate coercion on new larger disk drives, the disk size must be coerced down with a factor of 128 MB. Additionally, to comply with the latest Disk Data Format standard, 512 MB of space must be reserved for RAID metadata on the drive. This results in several hundred MB of space being removed from the usable size of an volume when it is created.

Status The status of the volume

This option is used to create or delete global hot spares. Using this option you can:

  • Assign a hot spare, (RAID 1 and RAID 10 configurations only).
  • Display each drive’s type, size and hot spare status.

50 PERC H200 and 6Gbps SAS HBA BIOS

Show 4 more labels / short text on this page
View Volume · Manage Volume · Field Description · Manage Hotspares
Page 51 of the Dell PowerEdge H200 user manual — Performing Configuration Tasks
Page 51 · click to enlarge
Page 51

Table 6-3. Manage Volume Field Descriptions (continued)

This option is used to run a consistency check on a redundant RAID volume.

This option is grayed out under the following conditions:

  • The volume is RAID 0
  • The volume is not optimal
  • The volume has a consistency check pending
  • The volume is already running a consistency check

This option is used to activate an inactive (foreign) volume. The option is grayed out if there are no inactive arrays.

This option is used to delete the currently displayed volume.

It is important to exit the SAS BIOS Configuration Utility properly, because some changes take effect only when you exit. From the Adapter List, press to exit. In addition, a similar exit screen appears when you exit most other screens, and it can be used to save settings.

Performing Configuration Tasks

The following configuration tasks can be performed using a PERC H200 card:

  • Creating a RAID 0, RAID 1, or RAID 10 virtual disk
  • Viewing virtual disk properties
  • Activating a virtual disk
  • Migrating and Activating a virtual disk
  • Hot Spare failover
  • Replacing and Rebuilding a degraded virtual disk
  • Assigning a Preferred Boot Device

PERC H200 and 6Gbps SAS HBA BIOS 51

Show 5 more labels / short text on this page
Field Description · Consistency Check · Activate Volume · Delete Volume · Exit Screen
Page 52 of the Dell PowerEdge H200 user manual — Creating a RAID 0 Virtual Disk
Page 52 · click to enlarge
Page 52

The PERC H200 card supports a minimum of two drives and maximum of 10 drives for a RAID 0 volume. Two drives are required to configure a RAID 1 volume, and a minimum of four drives and a maximum of 10 drives for a RAID 10 volume. There can be no more than 14 configured drives in any system, including a maximum of two global hot spares.A configured drive is a drive that is part a RAID volume or is a hot spare.

Creating a RAID 0 Virtual Disk

A RAID 0 virtual disk offers the ability to stripe data across multiple physical disks. RAID 0 volumes offer increased capacity by combining multiple physical disks into a single virtual disk. RAID 0 volumes also offer increased performance by striping disk access across multiple physical disks. Follow these steps to create a RAID 0 virtual disk on a PERC H200 card.

1 Select a controller from the Adapter List in the Configuration Utility.

2 Select the RAID Properties option.

3 Select Create RAID 0 Volume when you are prompted to create either a RAID 0 virtual disk, a RAID 1 virtual disk or a RAID 10 virtual disk.

The next screen shows a list of disks that can be added to a virtual disk.

4 Move the cursor to the RAID Disk column. To add a disk to the virtual disk, change No to Yes by pressing the , , or space bar. As disks are added, the Virtual Disk Size field changes to reflect the size of the new virtual disk.

There are several limitations when creating a RAID 0 virtual disk:

  • All disks must be either Dell-compliant SAS or SATA HDDs or SSDs.
  • SAS and SATA physical disks cannot be used in the same virtual disk.
  • HDDs or SSDs cannot be used in the same virtual disk.
  • There must be at least 2 physical disks in a virtual disk.
  • No more than 10 physical disks are allowed in a virtual disk.

52 PERC H200 and 6Gbps SAS HBA BIOS

Page 53 of the Dell PowerEdge H200 user manual — Creating a RAID 1 Virtual Disk
Page 53 · click to enlarge
Page 53

5 Press and then select Save changes when the virtual disk has been fully configured.

The Configuration Utility pauses while the virtual disk is being created.

failure. It is primarily used to increase performance.

system is 2 Tb. This is due to operating system restrictions.The maximum volume size (non-bootable) is 16 Tb.

Creating a RAID 1 Virtual Disk

A RAID 1 virtual disk offers the ability to mirror data from one physical disk onto another one. RAID 1 volumes offer increased reliability by combining two physical disks into a single virtual disk such that each disk contains a mirrored copy of the other’s data. Follow these steps to create a RAID 1 virtual disk on a PERC H200 card that does not currently have a virtual disk configured.

1 Select a controller from the Adapter List in the Configuration Utility.

2 Select the RAID Properties option.

3 Select Create RAID 1 Volume when you are prompted to create either a RAID 0 virtual disk, a RAID 1 virtual disk or a RAID 10 virtual disk. The next screen shows a list of disks that can be added to a virtual disk.

4 Move the cursor to the RAID Disk column. To add a disk to the virtual disk, change No to Yes by pressing the , , or space bar.

all data before performing these steps.

There are several limitations when creating a RAID 1 virtual disk:

  • All disks must be either Dell-compliant SAS, SATA or SSD physical disks.
  • SAS, SATA or SSD physical disks cannot be used in the same virtual disk.
  • There must be 2 physical disks in a RAID 1 virtual disk.

PERC H200 and 6Gbps SAS HBA BIOS 53

Page 54 of the Dell PowerEdge H200 user manual — Creating a RAID 10 Virtual Disk
Page 54 · click to enlarge
Page 54

5 Press and then select Save changes when the virtual disk has been fully configured.

After the virtual disk is created, entering the Manage Hot Spares screen allows the option to assign a hot spare. Only drives that are compatible with the new virtual disk configuration can be selected. The maximum number of hot spares allowed is two.

When a disk fails, the physical disk can be replaced and the data re-mirrored to the physical disk, maintaining data integrity.

6 Once the virtual disk has been created, a Background Initialization will automatically be scheduled on the virtual disk.

any time. If there is already a resynchronization or Background Initialization in progress on another virtual disk when a new virtual disk is created, the Background Initialization for the new virtual disk will be scheduled and given a status of BGI Pending. The pending Background Initialization will automatically start when the existing background process completes.

a RAID 10 virtual disk. Once started, the background initialization process cannot be stopped.

Creating a RAID 10 Virtual Disk

A RAID 10 virtual disk offers the ability to stripe data across mirrored disks. RAID 10 volumes offer high data throughput and complete data redundancy. Follow these steps to create a RAID 10 virtual disk on a PERC H200 card that does not currently have a virtual disk configured.

1 Select a controller from the Adapter List in the Configuration Utility.

2 Select the RAID Properties option.

3 Select Create RAID 10 Volume when you are prompted to create either a RAID 0 virtual disk, a RAID 1 virtual disk or a RAID 10 virtual disk. The next screen shows a list of disks that can be added to a virtual disk.

4 Move the cursor to the RAID Disk column. To add a disk to the virtual disk, change No to Yes by pressing the , , or the space bar. As disks are added, the Virtual Disk Size field changes to reflect the size of the new virtual disk.

54 PERC H200 and 6Gbps SAS HBA BIOS

Page 55 of the Dell PowerEdge H200 user manual — Creating a RAID 10 Virtual Disk
Page 55 · click to enlarge
Page 55

data before performing these steps.

There are several limitations when creating a RAID 10 virtual disk:

  • All disks must be either Dell-compliant SAS or SATA HDDs or SSDs.
  • SAS and SATA physical disks cannot be used in the same virtual disk.
  • HDDs and SSDs cannot be used in the same virtual disk.
  • There must be a minimum of 4 physical disks and a maximum of 10 physical disks in a RAID 10 virtual disk. An even number of physical disks need to be selected for a RAID 10 volume.

5 Press and then select Save changes when the virtual disk has been fully configured.

After the virtual disk is created, entering the Manage Hot Spares screen allows the option to assign a hot spare. Only drives that are compatible with the new virtual disk configuration can be selected. There is a maximum of 2 hot spares supported globally. Hot spares only apply to a redundant volume if it is of the same type and at least the same capacity of the volume.

6 Once the virtual disk has been created, a Background Initialization is automatically scheduled on the virtual disk.

disks, as long as both drives within a mirrored pair do not fail. When a disk fails, the physical disk can be replaced and the data re-mirrored to the physical disk, maintaining data integrity.

time. If there is already a resynchronization or Background Initialization in progress on another virtual disk when a new virtual disk is created, the Background Initialization for the new virtual disk will be scheduled and given a status of BGI Pending. The pending Background Initialization will automatically start when the existing background process completes.

virtual disk. Once started, the background initialization process cannot be stopped.

PERC H200 and 6Gbps SAS HBA BIOS 55

Page 56 of the Dell PowerEdge H200 user manual — Viewing Virtual Disk Properties
Page 56 · click to enlarge
Page 56

Viewing Virtual Disk Properties

Follow these steps to view the properties of RAID 0, RAID 1 or RAID 10 virtual disks:

1 Select a controller from the Adapter List in the Configuration Utility.

2 Select the RAID Properties option.

  • If there are no existing virtual disks, you will be prompted to create a RAID 0, RAID 1 or RAID 10 virtual disk.
  • If there is one existing virtual disk, select View Existing volume .
  • If there are two existing virtual disks, press <Alt><N> to view the next virtual disk.
  • If a compatible global hot spare exists it displays with the members of the virtual disk.

3 Press when the Manage volume item is selected to manage the current virtual disk.

Activating a Virtual Disk

A virtual disk can become inactive if, for example, it is removed from one PERC H200 card and moved to another one. The Activate option allows you to reactivate an inactive virtual disk that has been added to a system. This option is only available when the selected virtual disk is currently inactive.

system does not currently have the maximum number of virtual disks and hotspares. There is a maximum of 2 hot spares and 2 virtual disks supported globally. Hot spares only apply to a redundant volume if it is of the same type and at least the same capacity of the volume. Exceeding this number may result in undesirable behavior.

56 PERC H200 and 6Gbps SAS HBA BIOS

Page 57 of the Dell PowerEdge H200 user manual — Migrating and Activating a Virtual Disk
Page 57 · click to enlarge
Page 57

1 Select Activate Volume.

2 Press Y to proceed with the activation or press N to abandon it.

After a pause, the virtual disk will become active.

virtual disk(s) is in an optimal state and contains all the physical disks.

card that has a native virtual disk with defined hot spares already configured, and the total number of hot spares is greater than the maximum supported number of hot spares (2) then the migrated hot spare drive(s) will be deleted. After a reboot, those drives are displayed as basic drives on the system. You can then create the desired virtual disk and hot spare drive configuration using or the RAID management application.

Migrating and Activating a Virtual Disk

Virtual disks and hot spares can be migrated from other PERC H200 and SAS 6 series of controllers. Virtual disks cannot be migrated from any other controllers, including the SAS 5 series of controllers or PERC 5, PERC 6, PERC H700 and PERC H800 cards. Migration is only supported for virtual disks that are in the Optimal state. During the migration process, all systems must be powered down prior to removing and replacing drives. Volumes that are migrated to another controller will be inactive and must therefore be activated.To activate a virtual disk see "Activating a Virtual Disk" on page 56.

Deleting a Virtual Disk

disk that you want to keep.

Follow these steps to delete a selected virtual disk:

1 Select Delete Virtual Disk.

2 Press Y to delete the virtual disk or press N to abandon the deletion.

configuration is subsequently deleted from the PERC H200 card, the physical disks show up only as simple disks with no RAID association if they are placed back onto the same PERC H200 card. Once the virtual disk is removed from a PERC H200 card using the BIOS Configuration Utility (regardless whether the physical disks members are present), the virtual disk cannot be restored.

PERC H200 and 6Gbps SAS HBA BIOS 57

Page 58 of the Dell PowerEdge H200 user manual — Hot Spare Failover
Page 58 · click to enlarge
Page 58

If a RAID 1 or RAID 10 virtual disk enters a degraded state, a compatible hot spare automatically begins rebuilding the degraded virtual disk. The "missing" or "failed" member of the degraded virtual disk is displayed as a ‘missing’ global hot spare. The "missing" or "failed" drive must be replaced with a drive compatible with an existing virtual disk(s).

and of equal or greater size of the disk being replaced.

Replacing and Rebuilding a Degraded Virtual Disk

In the event of a physical disk failure in a RAID 1 or RAID 10 virtual disk, you will need to replace the disk and resynchronize the virtual disk. Synchronization occurs automatically on replacing the physical disk using the following steps.

1 Replace the failed physical disk with a blank disk of the same type and of equal or greater capacity.

2 Check your management application or the BIOS Configuration Utility () to ensure synchronization started automatically.

from the beginning if a hard drive is added or removed from the system. Wait until any synchronization processes have been completed before adding or removing hard drives.

be permanently removed from a system. This can be completed by deleting the RAID configuration through the BIOS Configuration Utility or an operating system unless you are migrating these hard drives to a different system level application. PERC H200 hotspare functionality requires that the slots in which hard drives are inserted be associated with the virtual disks they are a part of. Do not insert hard drives with foreign or old (out of date) configuration information stored on those hard drives into slots that are associated with existing virtual disks.

continues from where it left off as a result of rebuild checkpointing. The rebuild time for a volume varies depending on the size of the member disks and any additional system activity.

58 PERC H200 and 6Gbps SAS HBA BIOS

Hot Spare Failover

Page 59 of the Dell PowerEdge H200 user manual — Assigning a Preferred Boot Device
Page 59 · click to enlarge
Page 59

Assigning a Preferred Boot Device

When installing an operating system on the PERC H200 card, it is strongly recommended that the desired Preferred Boot Device is selected in the configuration utility. In the SAS topology screen in , you can scroll down to either select the desired unconfigured physical disk or virtual disk and assign that device as the Preferred Boot Device by pressing . The Preferred Boot Device is then be marked as Boot under Device Information. can be used to deselect a previously selected Preferred Boot Device as well.

Device, the selection is associated with the slot that the drive resides in. If the drive is then moved to a different slot, the system is not able to boot to the device anymore and an error message is seen during boot.

is associated with the virtual disk itself. If the volume is then moved to a different location in the system, the system will still identify the virtual disk as the Preferred Boot Device and be able to boot without any errors.

When a Preferred Boot Device goes missing, an error message is seen on POST, requiring user action to continue. The error message is as follows:

ERROR: Preferred boot device is missing, reconfiguration is suggested!

You need to enter to investigate the problem and select another Preferred Boot Device if needed.

In the scenario where you do not select a Preferred Boot Device, the boot device is chosen based on slot number, with the lowest number being given the highest priority. A message is displayed upon the first boot at POST stating which device has been assigned as the Boot Device.

PERC H200 and 6Gbps SAS HBA BIOS 59

Page 60 of the Dell PowerEdge H200 user manual — Assigning a Preferred Boot Device
Page 60 · click to enlarge
Page 60

The message looks something like the following for a virtual disk assignment:

Current Boot Device set to volume at handle 79

Boot under Device Information in .

If this device goes missing, the next device in the next available slot is selected as the Boot Device. Configured virtual disks are chosen as a boot device over unconfigured physical disks.

In summary, it is recommended to make a Preferred Boot Device selection in order to ensure that the desired boot device is always the device that the system boots to. All systems shipped from Dell have a Preferred Boot Device configured by default.

60 PERC H200 and 6Gbps SAS HBA BIOS

Page 61 of the Dell PowerEdge H200 user manual — Background Activities
Page 61 · click to enlarge
Page 61

Troubleshooting

To get help with problems with your Dell™ PowerEdge™ RAID Controller H200 or 6Gbps SAS HBA cards, you can see "Getting Help" on page 73 or access the Dell Support website at support.dell.com.

BIOS Boot Order

If you intend to boot to the controller, ensure it is set appropriately in the system's BIOS boot order. See your system documentation for more information.

Background Activities

Disk I/O performance may be degraded while the following background activities are functioning:

  • Background initialization
  • Consistency check
  • Disk rebuild

If disk I/O performance is lower than expected, check to see if any of these activities are running using a management application. If yes, wait until the background operation completes and recheck performance.

Troubleshooting 61

Page 62 of the Dell PowerEdge H200 user manual — General Issues
Page 62 · click to enlarge
Page 62

General Issues

Manager User’s Guide and the OpenManage Storage Services User’s Guide on the Dell Support website at support.dell.com.

Table 7-1. General Issues

No Physical Disks Found message appears during a CD installation of a Windows operating system.

The message appears due to one of the following reasons:

  • The driver is not supported on the operating system. (applicable to Windows 2003 operating systems only)
  • The controller BIOS is disabled.
  • Physical disks are not connected or seated properly.

The corresponding solutions to the three causes of the message are:

  • Press <F6> to install the Device Driver during installation.
  • Enter the BIOS Configuration Utility to enable the BIOS. See "PERC H200 and 6Gbps SAS HBA BIOS" on page 43.
  • Verify if the physical disks are connected or seated properly.

Issue Suggested Solution · 62 Troubleshooting

Page 63 of the Dell PowerEdge H200 user manual — Physical Disk Related Issues
Page 63 · click to enlarge
Page 63

Physical Disk Related Issues

Table 7-2. Physical Disk Issues

The system does not boot from the PERC H200 card.

Go to the Configuration Utility and verify the controller's boot order and also ensure that the desired Preferred Boot Device is set correctly.

Physical disk is not enumerated during POST.

  • Go to the Configuration Utility and ensure that the physical disk is not enumerated in the SAS topology.
  • Verify the cable connection.
  • Reseat the physical disk.
  • Check and reseat the cable.

One of the physical disks in the volume shows the status as "Failed".

  • Check the SAS cables.
  • Reseat the physical disk.
  • Check the enclosure or the backplane for damage.
  • Contact Dell if the problem persists.

RAID 1 or RAID 10 virtual disk does not rebuild.

  • Enter the Configuration Utility and ensure the physical disk is enumerated in the SAS topology.
  • Ensure the new disk is of the same drive type as the other disk in the virtual disk.
  • Ensure the new disk is of equal or greater capacity as the other disk in the virtual disk.
  • Ensure the new disk is not detected as an inactive virtual disk under the RAID Properties menu. Delete the newly inserted inactive disk.
  • Ensure the new disk is a Dell supported SAS, SATA or SSD disk.

Issue Suggested Solution · Troubleshooting 63

Page 64 of the Dell PowerEdge H200 user manual — Configuration Utility Error Messages
Page 64 · click to enlarge
Page 64

Configuration Utility Error Messages

Restart your system and retry if you encounter any of these.

steps mentioned in Table 7-3 for the resolution of the error, contact Dell Support for advanced troubleshooting. For information on how to contact Dell Technical Support, see "Getting Help" on page 73.

Table 7-3. Configuration Utility Error Messages

Message Meaning Suggested Solution

An error occurred while reading non-volatile settings.

An error occurred while reading any one of a number of settings from the firmware.

Reseat the controller and reboot.

An error occurred while reading current controller settings.

Controller setup and initialization has failed.

Reboot the system.

Advanced Device Properties settings not found.

Failed to read vital configuration page from firmware.

Reflash the firmware and reboot.

Error obtaining PHY properties configuration information.

Failed to read vital configuration page from firmware.

Reflash the firmware and reboot.

Configuration Utility Options Image checksum error.

Failed to properly read Configuration Utility options from flash.

Restart and retry. If the issue persists, reflash the firmware on the controller.

Can't load default Configuration Utility options.

Failed to allocate memory for Configuration Utility options structure.

An error occurred while writing non-volatile settings.

An error occurred while writing one or more settings to the firmware.

64 Troubleshooting

Page 65 of the Dell PowerEdge H200 user manual — BIOS Error Messages
Page 65 · click to enlarge
Page 65

BIOS Error Messages

Table 7-4. BIOS Error Messages

Press to Enable BIOS

When the BIOS is disabled, you are given the option to enable it by entering the Configuration Utility. You can change the setting to Enabled in the configuration utility.

Adapter configuration may have changed, reconfiguration is recommended!

Start the Configuration Utility and confirm the configuration of the PERC H200 or 6Gbps SAS HBA controller.

Press CTRL-C to run Dell PERC H200/6Gbps SAS HBA Configuration Utility…

Initializing... Displays while the BIOS is waiting to initialize.

SAS discovery error Indicates that there was a discovery error reported by the firmware and may be accompanied by more such messages. Enter the Configuration Utility to investigate.

Integrated RAID exception detected:

The BIOS detected an exception with one or more RAID virtual disk. For additional troubleshooting information, see the error message "Volume (xx:yy:zzz) is currently in state “STATE”.

Message Meaning · Troubleshooting 65

Page 66 of the Dell PowerEdge H200 user manual — BIOS Error Messages
Page 66 · click to enlarge
Page 66

Table 7-4. BIOS Error Messages (continued)

Volume (xx:yy:zzz) is currently in state “STATE”

Lists the current state of the specified virtual disk when it is not optimal. The state may include:

  • INACTIVE: The virtual disk is inactive, possibly foreign, or could be in any one of the states mentioned below.
  • DEGRADED: The virtual disk is in a degraded state and has lost redundancy.
  • RESYNCING: The virtual disk is degraded and currently rebuilding.
  • FAILED: The virtual disk has an error and is in a failed state.
  • MISSING: The virtual disk is no longer present though a record of it remains.
  • UNKNOWN: The virtual disk has an error that is not defined by the previous errors.

Device not available at HBA n,HDL n, LUN

Device may not be ready at this time. The device will be retried. If the problem persists, restart your system.

ERROR! Device is not responding to Read Capacity

The device did not respond to a read capacity command. Contact Dell.

Please wait, spinning up the boot device!

The boot device was inactive, and is now spinning up.

Devices in the process of spinning up

One or more devices were inactive and are now spinning up.

nn drives are reported, BIOS memory allocation is full!

The reported drives consumed all of the available memory, no more memory can be allocated.

Failed to add device, too many devices!

Could not allocate resources for additional devices.

Message Meaning · 66 Troubleshooting

Page 67 of the Dell PowerEdge H200 user manual — BIOS Error Messages
Page 67 · click to enlarge
Page 67

Table 7-4. BIOS Error Messages (continued)

The adapter did not initialize properly. There may be a problem with the adapter configuration. Reload the BIOS configuration. Invoke the configuration utility again and see if the issue persists.

MPT firmware fault The LSI Logic MPT firmware faulted. Contact Dell.

Adapter removed from boot order!

An controller that was previously in the boot order was not found. It has either been removed from the system or moved to a different slot.

A new adapter was found for which there is no record. A record will be created for it.

Adapter(s) disabled by user

An adapter was found, but it has been disabled in the Configuration Utility and will not be used by the BIOS.

Adapter configuration may have changed, reconfiguration is suggested!

A controller has been moved or reinstalled in the system. Add it to the boot order using the available resources.

The controller could not allocate enough memory to load the Configuration Utility, its strings file, or its options file. Reboot the system.

Invalid or corrupt image

One of the images for the Configuration Utility, its strings file, or its options file is corrupt. Reload the BIOS. Reflash the firmware.

Image upload failed Could not upload the image for the Configuration Utility, its strings file, or its options file. Reload the BIOS.Reflash the firmware.

Unable to load the Dell PERC H200/HBA Configuration Utility

Could not load the Configuration Utility. This error usually follows one of the four previous messages.

Dell PERC H200/HBA configuration utility will load after initialization!

is struck with the intention of starting the configuration utility but insufficient memory is available. The configuration utility therefore loads (boot) after POST initialization.

Show 5 more labels / short text on this page
Message Meaning · ERROR! Adapter Malfunctioning! · Updating Adapter List! · Memory allocation failed · Troubleshooting 67
Page 68 of the Dell PowerEdge H200 user manual — BIOS Error Messages
Page 68 · click to enlarge
Page 68

Table 7-4. BIOS Error Messages (continued)

MPT BIOS Fault xxh encountered at adapter PCI (xxh, xxh, xxh)

Fault 01: No I/O port assigned to the adapter.

Fault 02: A MPT firmware fault occurred.

Fault 03: No image for firmware download boot.

Fault 04: Firmware download boot checksum error.

Fault 05: IOC hardware error.

Fault 06: MPT firmware communication error.

Fault 07: PCI bus master error.

Fault 08: String image (messages) not found.

Fault 09: String memory allocation failed.

Fault 0A: String upload failed.

Fault 0B: String image was invalid.

Fault 0C: Unsupported IOC configuration.

Fault 0D: Timeout waiting for IOC to reply.

Fault 0E: Transmit doorbell handshake error.

Fault 0F: Receive doorbell handshake error.

Fault 10: No memory mapped I/O address assigned.

Fault 11: IOC facts failure.

Fault 12: IOC initialization failure.

Fault 13: Port enable failure.

MPT BIOS Fault xxh encountered at adapter PCI (xxh, xxh, xxh)

When xxh is 02 or 11, a 4-digit hexadecimal fault value may be displayed with this message. Ensure that you make a note of this value and contact technical support for assistance.

Message Meaning · 68 Troubleshooting

Page 69 of the Dell PowerEdge H200 user manual — BIOS Error Messages
Page 69 · click to enlarge
Page 69

Table 7-4. BIOS Error Messages (continued)

ERROR: Preferred boot device is missing, reconfiguration is suggested!

The message indicates that the preferred boot device selected in the Configuration Utility is no longer available. You must enter the Configuration Utility and specify the physical or virtual disk to be the boot device. For details on assigning boot device preference, see "Assigning a Preferred Boot Device" on page 59.

One or more unsupported device detected!

There is a topology error during device scan.

SAS Address NOT programmed on controller in slot xx

The SAS address (World Wide ID) equals zero and is not programmed

Detected metadata is not supported by integrated RAID.

Device has an unsupported sector size, not 512

The sector size is not 512 bytes that is a requirement for boot support.

Bus master ERROR! The bus master enable was not set for the chip.

Error: Preferred boot device is missing, reconfiguration is suggested!

The selected boot device is not found.

Message Meaning · Troubleshooting 69

Page 70 of the Dell PowerEdge H200 user manual — BIOS Error Messages
Page 70 · click to enlarge
Page 70

70 Troubleshooting

Page 71 of the Dell PowerEdge H200 user manual — Firmware Package Update Utility
Page 71 · click to enlarge
Page 71

Updating the Firmware

Updating the Dell™ PowerEdge™ RAID Controller H200 or 6Gbps SAS HBA card firmware package is achieved by flashing the firmware package. The firmware package can be flashed while the controller is in use. The system must be restarted for all changes to take effect. If there is a failure while flashing the firmware package (such as a power outage) the controller reverts back to the earlier version of the firmware.

temporary degradation in the controller's performance.

Firmware Package Update Utility

Firmware package update utility can be run from a variety of operating systems. This flash is automated and no user intervention is required. You can obtain the firmware package flash utility from the PowerEdge Service and Diagnostic Utilities media that shipped with your system.

You have to perform a manual update. In the event of new firmware package release, check the Dell Support website at support.dell.com for the latest firmware package updates and the firmware package update procedure.

Appendix AUpdating the Firmware 71
Page 72 of the Dell PowerEdge H200 user manual — Updating the Firmware
Page 72 · click to enlarge
Page 72
72 Appendix AUpdating the Firmware
Page 73 of the Dell PowerEdge H200 user manual — Getting Help
Page 73 · click to enlarge
Page 73

Getting Help

computer power and modem cables from all electrical outlets.

If you need assistance with a technical problem, perform the following steps:

1 Complete the procedures in the section "Troubleshooting Your System" of your system’s Hardware Owner’s Manual.

2 Run the system diagnostics and record any information provided.

3 Use Dell's extensive suite of online services available at Dell Support at support.dell.com for help with installation and troubleshooting procedures.

For more information, see "Online Services" on page 74.

4 If the preceding steps have not resolved the problem, call Dell for technical assistance.

support staff can assist you with any necessary procedures.

When prompted by Dell's automated telephone system, enter your Express Service Code to route the call directly to the proper support personnel.

If you do not have an Express Service Code, open the Dell Accessories folder, double-click the Express Service Code icon, and follow the directions.

For instructions on using the technical support service, see "Dell Enterprise Training" on page 75 and "Before You Call" on page 76.

outside the continental U.S. Call your local Dell representative for information on availability.

Technical Support and Customer Service

To contact Dell's support service, see "Before You Call" on page 76, and then see the contact information for your region or go to support.dell.com.

Appendix BGetting Help 73
Page 74 of the Dell PowerEdge H200 user manual — Online Services
Page 74 · click to enlarge
Page 74

You can access Dell Support at support.dell.com. Select your region on the Welcome To Dell Support page, and fill in the requested details to access help tools and information.

You can learn about Dell products and services on the following websites:

www.dell.com

www.dell.com/ap (Asian/Pacific countries only)

www.dell.com/jp (Japan only)

www.euro.dell.com (Europe only)

www.dell.com/la (Latin American and Caribbean countries)

www.dell.ca (Canada only)

You can access Dell Support by using the following websites and e-mail addresses:

  • Dell Support websites

support.dell.com

support.jp.dell.com (Japan only)

support.euro.dell.com (Europe only)

  • Dell Support e-mail addresses

mobile_support@us.dell.com

support@us.dell.com

la-techsupport@dell.com (Latin America and Caribbean countries only)

apsupport@dell.com (Asian/Pacific countries only)

  • Dell Marketing and Sales e-mail addresses

apmarketing@dell.com (Asian/Pacific countries only)

sales_canada@dell.com (Canada only)

  • Anonymous file transfer protocol (FTP)

ftp.dell.com/

Log in as user: anonymous, and use your e-mail address as your password.

74 Appendix BGetting Help

Online Services

Page 75 of the Dell PowerEdge H200 user manual — Product Information
Page 75 · click to enlarge
Page 75

To check on the status of any Dell products that you have ordered, you can go to support.dell.com, or you can call the automated order-status service. A recording prompts you for the information needed to locate and report on your order. See the contact information for your region.

Dell Enterprise Training

Dell Enterprise training is available; see www.dell.com/training for more information. This service may not be offered in all locations.

Problems With Your Order

If you have a problem with your order, such as missing parts, wrong parts, or incorrect billing, contact Dell for customer assistance. Have your invoice or packing slip available when you call. See the contact information for your region.

Product Information

If you need information about additional products available from Dell, or if you would like to place an order, visit the Dell website at www.dell.com For the telephone number to call to speak to a sales specialist, see the contact information for your region.

Appendix BGetting Help 75

Automated Order-Status Service

Page 76 of the Dell PowerEdge H200 user manual — Before You Call
Page 76 · click to enlarge
Page 76

Returning Items for Warranty Repair or Credit

Prepare all items being returned, whether for repair or credit, as follows:

1 Call Dell to obtain a Return Material Authorization Number, and write it clearly and prominently on the outside of the box.

For the telephone number to call, see the contact information for your region.

2 Include a copy of the invoice and a letter describing the reason for the return.

3 Include a copy of any diagnostic information indicating the tests you have run and any error messages reported by the system diagnostics.

4 Include any accessories that belong with the item(s) being returned (such as power cables, media such as CDs and diskettes, and guides) if the return is for credit.

5 Pack the equipment to be returned in the original (or equivalent) packing materials.

You are responsible for paying shipping expenses. You are also responsible for insuring any product returned, and you assume the risk of loss during shipment to Dell. Collect-on-delivery (C.O.D.) packages are not accepted.

Returns that are missing any of the preceding requirements will be refused at our receiving dock and returned to you.

Before You Call

automated-support telephone system direct your call more efficiently.

and codes provided to contact Dell Support.

If possible, turn on your system before you call Dell for technical assistance and call from a telephone at or near the system. You may be asked to type some commands at the keyboard, relay detailed information during operations, or try other troubleshooting steps possible only at the system itself. Ensure that the system documentation is available.

safety information for the system.

76 Appendix BGetting Help
Page 77 of the Dell PowerEdge H200 user manual — Regulatory Notices
Page 77 · click to enlarge
Page 77

Regulatory Notices

For additional regulatory information, please go to the Regulatory Compliance Homepage on www.dell.com at the following location: www.dell.com/regulatory_compliance

Dell PowerEdge H200 — Regulatory Notices diagram (page 77)
Fig. 6 · Regulatory Notices
Dell PowerEdge H200 — Regulatory Notices diagram (page 77)
Fig. 7 · Regulatory Notices
Appendix CRegulatory Notices 77
Page 78 of the Dell PowerEdge H200 user manual — Regulatory Notices
Page 78 · click to enlarge
Page 78
Dell PowerEdge H200 — Regulatory Notices diagram (page 78)
Fig. 8 · Regulatory Notices
Dell PowerEdge H200 — Regulatory Notices diagram (page 78)
Fig. 9 · Regulatory Notices
78 Appendix CRegulatory Notices
Page 79 of the Dell PowerEdge H200 user manual — Corporate Contact Details (Taiwan Only)
Page 79 · click to enlarge
Page 79

Corporate Contact Details (Taiwan Only)

Pursuant to Article 11 of the Commodity Inspection Act, Dell provides the following corporate contact details for the certified entity in Taiwan for the products addressed by this document:

Dell B.V. Taiwan Branch

20/F, No. 218, Sec. 2, Tung Hwa S. Road,

Appendix DCorporate Contact Details (Taiwan Only) 79

Taipei, Taiwan

Page 80 of the Dell PowerEdge H200 user manual — Corporate Contact Details (Taiwan Only)
Page 80 · click to enlarge
Page 80
80 Appendix DCorporate Contact Details (Taiwan Only)
Page 81 of the Dell PowerEdge H200 user manual — B
Page 81 · click to enlarge
Page 81

Glossary

This section defines or identifies technical terms, abbreviations, and acronyms used in this document.

A

An adapter enables the computer system to access peripheral devices by converting the protocol of one bus or interface to another. An adapter may also provide specialized function. Adapters may reside on the system board or be an add-in card. Other examples of adapters include network and SCSI adapters.

B

BIOS

(Basic Input/Output System) The part of the operating system in a system that provides the lowest level interface to peripheral devices. BIOS also refers to the Basic Input/Input Output System of other “intelligent” devices, such as RAID controllers.

The BIOS Configuration Utility reports and enables the configuration of controller properties. The utility resides in the controller BIOS and its operation is independent of the operating systems on your system. The BIOS Configuration Utility, also known as Ctrl-C, is built on elements called controls. Each control performs a function.

Coercion is the process of rounding down the number of Logical blocks used for the physical members of a virtual disk to a common number. This allows drives with different absolute capacities, which can vary between drive manufacturers and drive families, to share a common stripe size and count as members of the virtual disk. Coercion necessarily results in a smaller capacity than was available on the un-coerced basic physical drive.

Show 4 more labels / short text on this page
Adapter · BIOS Configuration Utility · Coercion · Glossary 81
Page 82 of the Dell PowerEdge H200 user manual — DKMS
Page 82 · click to enlarge
Page 82

A chip that controls the transfer of data between the microprocessor and memory or between the microprocessor and a peripheral device such as a physical disk or the keyboard. In Storage Management, the hardware or logic that interacts with storage devices to write and retrieve data and perform storage management. RAID controllers perform RAID functions such as striping and mirroring to provide data protection.

D

A non-volatile, randomly addressable, rewriteable mass storage device, including rotating magnetic, optical and solid-state storage devices, or non-volatile electronic storage elements.

DKMS

DKMS stands for Dynamic Kernel Module Support. It is designed to create a framework where kernel dependent module source can reside so that it is very easy to rebuild modules as you upgrade kernels. This will allow Linux vendors to provide driver drops without having to wait for new kernel releases while also taking out the guesswork for customers attempting to recompile modules for new kernels.

A device driver, often called a driver for short, is a program that allows the operating system or some other program to interface correctly with a peripheral device such as a printer, a network PC card or the PERC H200 card.

DUD (Driver Update Diskette)

Acronym for driver update diskette. A DUD is an image of a diskette stored as a regular file. To use it, you have to create a real diskette from this file. The steps used to create the diskette depend on how the image is supplied.

Show 4 more labels / short text on this page
Controller · Disk · Driver · 82 Glossary
Page 83 of the Dell PowerEdge H200 user manual — H
Page 83 · click to enlarge
Page 83

F

Software stored in read-only memory (ROM) or Programmable ROM (PROM). Firmware is often responsible for the behavior of a system when it is first turned on. A typical example would be a monitor program in a system that loads the full operating system from disk or from a network and then passes control to the operating system.

Sometimes referred as simply "flash", is a compact, solid-state, rewriteable, non-volatile memory device that retains its data when the power is turned off. It offers fast access time, low power consumption, and relative immunity to severe shock or vibration. It is a special type of EEPROM that can be erased and reprogrammed in blocks instead of one byte at a time. Many modern PCs have their BIOS stored on a flash memory chip so that it can easily be updated if necessary. Such a BIOS is sometimes called a flash BIOS.

H

The mechanical, magnetic, electronic, and electrical components making up a computer system constitutes its hardware.

It is the addition/removal of a component while the system is running and operating normally.

A connection between any two PCI Express devices is known as a link.

Show 6 more labels / short text on this page
Firmware · Flash Memory · Hardware · Hot Add/Remove · Link · Glossary 83
Page 84 of the Dell PowerEdge H200 user manual — O
Page 84 · click to enlarge
Page 84

M

Megahertz or one million cycles per second is a unit of frequency commonly used to measure the operating speed of a computer processor or any other electronic component.

The process of providing complete redundancy using two physical disks, by maintaining an exact copy of one physical disk’s data on the second physical disk. If one physical disk fails, the contents of the other physical disk can be used to maintain the integrity of the system and to rebuild the failed physical disk.

O

The software that runs a computer, including scheduling tasks, managing storage, and handling communication with peripherals and performs basic input/output functions, such as recognizing input from the keyboard, sending output to the display screen, etc. is called an operating system.

Show 4 more labels / short text on this page
MHz · Mirroring · Operating System · 84 Glossary
Page 85 of the Dell PowerEdge H200 user manual — POST
Page 85 · click to enlarge
Page 85

P

PCI Express (PCI-E) is an evolutionary upgrade to the existing Peripheral Component Interconnect (PCI) bus. PCI-E is a serial connection that operates more like a network than a bus. Instead of one bus that handles data from multiple sources, PCI-E has a switch that controls several point-to-point serial connections. These connections fan out from the switch, leading directly to the devices where the data needs to go. Every device has its own dedicated connection, so devices no longer share bandwidth like they do on a normal bus.

PHY

The interface required to transmit and receive data packets transferred across the serial bus. Each PHY can form one side of the physical link in a connection with a PHY on a different Dell-qualified SATA device. The physical link contains four wires that form two differential signal pairs. One differential pair transmits signals, while the other differential pair receives signals. Both differential pairs operate simultaneously and allow concurrent data transmission in both the receive and the transmit directions.

A physical disk (also known as hard disk drive) consists of one or more rigid magnetic discs rotating about a central axle, with associated read/write heads and electronics. A physical disk is used to store information, (data), in a non-volatile and randomly accessible memory space.

POST

POST, short for Power-On Self-Test is a process performed before the operating system loads when the computer is turned on. The POST tests various system components, such as RAM, the physical disks, and the keyboard.

PCI Express (PCI-E) · Physical Disk · Glossary 85

Page 86 of the Dell PowerEdge H200 user manual — S
Page 86 · click to enlarge
Page 86

R

RAID

Acronym for Redundant volume of Independent Disks (originally Redundant volume of Inexpensive Disks). It is an volume of multiple independent physical disks managed together to yield higher reliability and/or performance exceeding that of a single physical disk. The virtual disk appears to the operating system as a single storage unit. I/O is expedited because several disks can be accessed simultaneously. Redundant RAID levels provide data protection.

ROM

Read-only memory (ROM), also known as firmware, is an integrated circuit programmed with specific data when it is manufactured. ROM chips are used not only in computers, but in most other electronic items as well. Data stored in these chips is nonvolatile i.e., it is not lost when the power is turned off. Data stored in these chips is either unchangeable or requires a special operation such as flashing to change.

RPM

RPM, short for "Red Hat Package Manager" is a package management system primarily intended for Linux. RPM installs, updates, uninstalls, verifies and queries software. RPM is the baseline package format of the Linux Standard Base. Originally developed by Red Hat for Red Hat Linux, RPM is now used by many Linux distributions. It has also been ported to some other operating systems such as NetWare by Novell.

S

SAS

Serial-Attached SCSI, SAS, is a serial, point-to-point, enterprise-level device interface that leverages the proven SCSI protocol set. The SAS interface provides improved performance, simplified cabling, smaller connectors, lower pin count, and lower power requirements when compared to parallel SCSI.

86 Glossary

Page 87 of the Dell PowerEdge H200 user manual — SCSI
Page 87 · click to enlarge
Page 87

SATA

Serial Advanced Technology Attachment, a physical storage interface standard, is a serial link that provides point-to-point connections between devices. The thinner serial cables allow for better airflow within the system and permit smaller chassis designs.

SCSI

SCSI stands for "Small Computer System Interface," a processor-independent standard interface for system-level interfacing between a computer and intelligent devices including hard-drives, floppy disks, CD-ROM, printer, scanners and many more.

SCSIport driver is a Microsoft® driver for Windows® XP storage architecture, delivering SCSI commands to the storage targets. The SCSIport driver works well with storage using parallel SCSI.

Serial architectures have emerged to deliver higher performance by allowing more bandwidth per device pathway than their parallel counterparts. Serial architecture connections consist of a single pair of transmission signals that contain an embedded clock for self-clocking, enabling clock speed to be easily scaled. Serial bus architectures also support a network of dedicated point-to-point device connections, versus the multi-drop architectures of parallel buses, to deliver full bandwidth to each device, eliminate the need for bus arbitration, reduce latency, and greatly simplify hot-plug and hot-swap system implementations.

Serial storage technology, specifically Serial ATA, Serial-Attached SCSI and PCI Express, address the architectural limitations of their parallel counterparts to deliver highly scalable performance. The technology draws its name from the way it transmits signals - in a single stream, or serially, compared to multiple streams for parallel. The main advantage of serial technology is that while it moves data in a single stream, it wraps data bits into individual packets that are transferred up to 30 times faster than parallel technology data.

Show 4 more labels / short text on this page
SCSIport · Serial Architecture · Serial Technology · Glossary 87
Page 88 of the Dell PowerEdge H200 user manual — W
Page 88 · click to enlarge
Page 88

SMART

Acronym for Self-Monitoring Analysis and Reporting Technology. The self-monitoring analysis and reporting technology (SMART) feature monitors the internal performance of all motors, heads, and drive electronics to detect predictable drive failures. This feature helps monitor drive performance and reliability, and protects the data on the drive. When problems are detected on a drive, you can replace or repair the drive without losing any data. SMART-compliant disks have attributes for which data (values) can be monitored to identify changes in values and determine whether the values are within threshold limits. Many mechanical failures and some electrical failures display some degradation in performance before failure.

The Storport driver has been designed to replace SCSIport and work with Windows 2003 and beyond. In addition, it offers better performance for storage controllers, providing higher I/O throughput rates, improved manageability, and an upgraded miniport interface.

A stripe element is the portion of a stripe that resides on a single physical disk.

Disk striping writes data across all physical disks in a virtual disk. Each stripe consists of consecutive virtual disk data addresses that are mapped in fixed-size units to each physical disk in the virtual disk using a sequential pattern. For example, if the virtual disk includes five physical disks, the stripe writes data to physical disks one through five without repeating any of the physical disks. The amount of space consumed by a stripe is the same on each physical disk. The portion of a stripe that resides on a physical disk is a stripe element. Striping by itself does not provide data redundancy.

W

Microsoft Windows is a range of commercial operating environments for computers. It provides a graphical user interface (GUI) to access programs and data on the computer.

Show 5 more labels / short text on this page
Storport · Stripe Element · Striping · Windows · 88 Glossary
Page 89 of the Dell PowerEdge H200 user manual — XP
Page 89 · click to enlarge
Page 89

XP

XP is a Microsoft Windows operating system. Released in 2001, it is built on the Windows 2000 kernel, making it more stable and reliable than previous versions of Windows. It includes an improved user interface and more mobility features, such as plug and play features used to connect to wireless networks.

Glossary 89

Page 90 of the Dell PowerEdge H200 user manual — Glossary
Page 90 · click to enlarge
Page 90

90 Glossary

Page 91 of the Dell PowerEdge H200 user manual — Table of Contents
Page 91 · Contents
Contents

Contents

CAUTION: Safety Instructionsp.9SAFETY: Generalp.9SAFETY: When Working Inside Your Systemp.10Protecting Against Electrostatic Dischargep.10SAFETY: Battery Disposalp.11Overviewp.13Operating System Supportp.14About RAIDp.15RAID Levelsp.15RAID Terminologyp.15RAID 0p.15RAID 1p.16RAID 10p.17PERC H200 and 6Gbps SAS HBA Featuresp.19LED Port Activity Feature for 6Gbps SAS HBA Onlyp.23Physical Disk Cache Policyp.24Unsupported Drivesp.24Hardware Installationp.25Installing the PERC H200 and 6Gbps SAS HBA Cardsp.25Installing the PERC H200 Modular Cardp.29Driver Installationp.31Installing the Windows Driverp.32Creating the Driver Mediap.32Pre-Installation Requirementsp.32Installing the Driver During a Windows Server 2003 Operating System Installationp.33Installing the Driver During a Windows Server 2008 or Windows Server 2008 R2 Installationp.34Installing a Windows Server 2003, Windows Server 2008 or Windows Server 2008 R2 Driver for a New RAID Controllerp.35Updating the Windows Driverp.36Installing Linux Driverp.37Creating a DUDp.37Creating a DUD Using DKMSp.39Installing Red Hat Enterprise Linux Operating System Using the DUDp.39Installing SUSE Linux Enterprise Server Using the DUDp.40Installing the RPM Package With DKMS Supportp.41Upgrading the Kernelp.41PERC H200 and 6Gbps SAS HBA BIOSp.43POST Messagesp.43BIOS Fault Code Messagesp.43Booting With Multiple Controllersp.44Configuration Utilityp.44Starting the Configuration Utilityp.44Functions Performedp.44RAID Configuration and Management Screensp.46Select New Volume Typep.47Create New Volumep.47View Volumep.50Manage Volumep.50Exit Screenp.51Performing Configuration Tasksp.51Creating a RAID 0 Virtual Diskp.52Creating a RAID 1 Virtual Diskp.53Creating a RAID 10 Virtual Diskp.54Viewing Virtual Disk Propertiesp.56Activating a Virtual Diskp.56Migrating and Activating a Virtual Diskp.57Deleting a Virtual Diskp.57Hot Spare Failoverp.58Replacing and Rebuilding a Degraded Virtual Diskp.58Assigning a Preferred Boot Devicep.59Troubleshootingp.61BIOS Boot Orderp.61Background Activitiesp.61General Issuesp.62Physical Disk Related Issuesp.63Configuration Utility Error Messagesp.64BIOS Error Messagesp.65Updating the Firmwarep.71Firmware Package Update Utilityp.71Getting Helpp.73Technical Support and Customer Servicep.73Online Servicesp.74Automated Order-Status Servicep.75Dell Enterprise Trainingp.75Problems With Your Orderp.75Product Informationp.75Returning Items for Warranty Repair or Creditp.76Before You Callp.76Regulatory Noticesp.77Corporate Contact Details (Taiwan Only)p.79Glossaryp.81Indexp.91
Page 92 of the Dell PowerEdge H200 user manual — Table of contents
Page 92 · click to enlarge
Page 92

Table of contents

CAUTION: Safety Instructionsp.9SAFETY: Generalp.9SAFETY: When Working Inside Your Systemp.10Protecting Against Electrostatic Dischargep.10SAFETY: Battery Disposalp.11Overviewp.13Operating System Supportp.14About RAIDp.15RAID Levelsp.15RAID Terminologyp.15RAID 0p.15RAID 1p.16RAID 10p.17PERC H200 and 6Gbps SAS HBA Featuresp.19LED Port Activity Feature for 6Gbps SAS HBA Onlyp.23Physical Disk Cache Policyp.24Unsupported Drivesp.24Hardware Installationp.25Installing the PERC H200 and 6Gbps SAS HBA Cardsp.25Installing the PERC H200 Modular Cardp.29Driver Installationp.31Installing the Windows Driverp.32Creating the Driver Mediap.32Pre-Installation Requirementsp.32Installing the Driver During a Windows Server 2003 Operating System Installationp.33Installing the Driver During a Windows Server 2008 or Windows Server 2008 R2 Installationp.34Installing a Windows Server 2003, Windows Server 2008 or Windows Server 2008 R2 Driver for a New RAID Controllerp.35Updating the Windows Driverp.36Installing Linux Driverp.37Creating a DUDp.37Creating a DUD Using DKMSp.39Installing Red Hat Enterprise Linux Operating System Using the DUDp.39Installing SUSE Linux Enterprise Server Using the DUDp.40Installing the RPM Package With DKMS Supportp.41Upgrading the Kernelp.41PERC H200 and 6Gbps SAS HBA BIOSp.43POST Messagesp.43BIOS Fault Code Messagesp.43Booting With Multiple Controllersp.44Configuration Utilityp.44Starting the Configuration Utilityp.44Functions Performedp.44RAID Configuration and Management Screensp.46Select New Volume Typep.47Create New Volumep.47View Volumep.50Manage Volumep.50Exit Screenp.51Performing Configuration Tasksp.51Creating a RAID 0 Virtual Diskp.52Creating a RAID 1 Virtual Diskp.53Creating a RAID 10 Virtual Diskp.54Viewing Virtual Disk Propertiesp.56Activating a Virtual Diskp.56Migrating and Activating a Virtual Diskp.57Deleting a Virtual Diskp.57Hot Spare Failoverp.58Replacing and Rebuilding a Degraded Virtual Diskp.58Assigning a Preferred Boot Devicep.59Troubleshootingp.61BIOS Boot Orderp.61Background Activitiesp.61General Issuesp.62Physical Disk Related Issuesp.63Configuration Utility Error Messagesp.64BIOS Error Messagesp.65Updating the Firmwarep.71Firmware Package Update Utilityp.71Getting Helpp.73Technical Support and Customer Servicep.73Online Servicesp.74Automated Order-Status Servicep.75Dell Enterprise Trainingp.75Problems With Your Orderp.75Product Informationp.75Returning Items for Warranty Repair or Creditp.76Before You Callp.76Regulatory Noticesp.77Corporate Contact Details (Taiwan Only)p.79Glossaryp.81Indexp.91
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
01No I/O port assigned to the adapter. p.68
02A MPT firmware fault occurred. p.68
03No image for firmware download boot. p.68
04Firmware download boot checksum error. p.68
05IOC hardware error. p.68
06MPT firmware communication error. p.68
07PCI bus master error. p.68
08String image (messages) not found. p.68
09String memory allocation failed. p.68
0AString upload failed. p.68
0BString image was invalid. p.68
0CUnsupported IOC configuration. p.68
0DTimeout waiting for IOC to reply. p.68
0ETransmit doorbell handshake error. p.68
0FReceive doorbell handshake error. p.68
10No memory mapped I/O address assigned. p.68
11IOC facts failure. p.68
12IOC initialization failure. p.68
13Port enable failure. p.68

Ask about the Dell PowerEdge H200

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Dell PowerEdge H200

Be the first to ask — other owners or our team will answer.

Original document

Dell PowerEdge H200 manual PDF

92 pages·4.2 MB·Video Gaming Accessories·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…