Throughout this guide, blocks of text may be accompanied by an icon and printed in bold type or in italic type. These blocks are notes, notices, cautions, and warnings, and they are used as follows:
! " " #
$ %& $ %& ! " " #
Information in this document is subject to change without notice. © 2000 Dell Computer Corporation. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Computer Corpo- ration is strictly forbidden.
Trademarks used in this text: Dell, the DELL E COM logo, Dell OpenManage, PowerEdge, and PowerVault are trademarks of Dell Computer Corporation; Microsoft, Windows, and Windows NT are registered trademarks of Microsoft Corporation; Intel is a registered trademark of Intel Corporation.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Computer Corporation disclaims any propri- etary interest in trademarks and trade names other than its own.
June 2000 P/N 96ETT Rev. A00

This guide provides the latest information on using Microsoft® Windows NT®
Server 4.0, Enterprise Edition operating system and Windows® 2000 Advanced Server operating system for the following Dell PowerEdge Cluster FE100/FL100 products and components:
— Cluster interconnect: Intel® PRO/100+ Fast Ethernet controller, which can be a peripheral component interconnect (PCI) card or an integrated controller, if available
See the section related to your cluster product for more information on supported configurations. See also the Dell PowerEdge Cluster FE100/FL100 Installation and Troubleshooting Guide for a detailed list of related documentation.

The PowerEdge Cluster FE100 and FL100 support clustering on Windows NT Server 4.0, Enterprise Edition. See the following sections for information on sup- ported configurations and service packs. See also the Dell PowerEdge Cluster FE100/ FL100 Installation and Troubleshooting Guide for installation instructions for hardware configurations using Windows NT Server 4.0, Enterprise Edition.
Your PowerEdge Cluster FE100/FL100 system supports the following PowerEdge servers as cluster nodes in homogeneous pairs (same server) on Windows NT 4.0, Enterprise Edition:
Your PowerEdge Cluster FE100/FL100 system supports the following PowerEdge servers as cluster nodes in heterogeneous pairs (mixed server models) with Windows NT 4.0, Enterprise Edition:

Table 1 lists the QLogic HBAs and the PowerEdge servers on which they are sup- ported for Windows NT cluster configurations. For PCI slot recommendations, see the section for your server model on adding peripherals required for cluster nodes, found later in this document.
PowerEdge Servers 2400 2450 4300/ 4350 4400 6100 6300/ 6350 6400/ 6450 8450
QLA-2100/ 33-MHz x x x
QLA-2200/ 33-MHz x
QLA-2200/ 66-MHz x x x
The supported drivers for the QLogic HBAs in Windows NT configurations are as follows:
You can download the latest drivers from the Dell Web site at http://www.dell.com.
Windows NT Service Pack 6a or later is recommended for PowerEdge Cluster FE100/ FL100 systems.
QLogic HBAs

The PowerEdge Cluster FE100 and FL100 support clustering on Windows 2000 Advanced Server. See the following sections for information on supported configura- tions and service packs. See also the Dell PowerEdge Cluster FE100/FL100 Installation and Troubleshooting Guide for installation instructions for hardware config- urations using Windows 2000 Advanced Server.
Your PowerEdge Cluster FE100/FL100 configuration supports the following PowerEdge servers as cluster nodes in homogeneous pairs (same server) with Windows 2000 Advanced Server:

Table 2 lists the QLogic HBAs and the PowerEdge servers on which they are sup- ported for Windows 2000 cluster configurations. For PCI slot recommendations, see the section for your server model on adding peripherals required for cluster nodes, found later in this document.
PowerEdge Servers 2400 2450 4300/ 4350 4400 6300/ 6350 6400/ 6450 8450
QLA-2100/ 33-MHz x x
QLA-2200/ 33-MHz x
QLA-2200/ 66-MHz x x x
The supported drivers for the QLogic HBAs in Windows 2000 configurations are as follows:
You can download the latest drivers from the Dell Web site at http://www.dell.com.
No service pack is required at this time.
QLogic HBA

! !
The following sections describe adding peripherals for PowerEdge 2400, 2450, 4300, 4350, 4400, 6100, 6300, 6350, and 8450 cluster nodes.
$ %&' () " * #
The following list provides PCI slot assignment information for the system’s PCI buses, HBAs, and the Dell OpenManage Remote Assistant Card 2 (DRAC 2).
— PCI bus 1: PCI slot 6 is 32-bit, 33-MHz.
— Dell recommends installing the HBAs on separate PCI buses to balance the load on the system.
— If you are currently using a DRAC 2 or plan to use one in the future, install it in PCI slot 6.
The following list provides PCI slot assignment information for the system’s PCI buses and HBAs.
— You can install HBAs in any available PCI slot.

The following list provides PCI slot assignment information for the system’s PCI buses, HBAs, and the DRAC 2.
— PCI bus 0: PCI slots 1 through 4 are 32-bit, 33-MHz slots.
— PCI bus 1: PCI slots 5 and 6 are 32-bit, 33-MHz slots.
— Dell recommends installing the HBAs on separate PCI buses to balance the load on the system.
— If you are currently using a DRAC 2 or plan to use one in the future, install it in PCI slot 4.
The following list provides PCI slot assignment information for the systems’s PCI buses, HBAs, and the DRAC 2.
— PCI bus 0: PCI slots 1 and 2 are 64-bit, 33/66-MHz.
— PCI bus 2: PCI slot 7 is 32-bit, 33-MHz.
— Dell recommends installing the HBAs on separate PCI buses (PCI buses 1 and 2) to balance the load on the system.
— If you are currently using a DRAC 2 or plan to use one in the future, install it in PCI slot 7.

The following list provides PCI slot assignment information for the system’s PCI buses and HBAs.
— PCI bus 0: PCI slots 1 through 3 are 32-bit, 33-MHz slots.
— PCI bus 1: PCI slots 4 through 6 are 32-bit, 33-MHz slots.
— Dell recommends installing the HBAs on separate PCI buses to balance the load on the system.
The following list provides PCI slot assignment information for the system’s PCI buses, HBAs, and the DRAC 2.
— Dell recommends installing the HBAs on separate PCI buses to balance the load on the system.
— If you are currently using a DRAC 2 or plan to use one in the future, install it in PCI slot 3.
The following list provides PCI slot assignment information for the system’s PCI buses, HBAs, and the DRAC 2.
— PCI bus 0: PCI slot 1 is 32-bit, 33-MHz.
— PCI bus 2: PCI slots 6 and 7 are 64-bit, 33/66-MHz.
— Dell recommends installing the HBAs on separate PCI buses (PCI buses 2 and 3) to balance the load on the system.

— If you are currently using a DRAC 2 or plan to use one in the future, install it in PCI slot 1.
The following list provides PCI slot assignment information for the system’s PCI buses, RAID controllers, HBAs, and the DRAC 2.
— PCI bus 0: PCI slot 1 and 2 are 64-bit, 33-MHz.
— PCI bus 2: PCI slots 7 and 8 are 64-bit, 33/66-MHz.
— PCI bus 3: PCI slots 9 and 10 are 64-bit, 33/66-MHz.
— Install the RAID controller for the server’s internal drives in PCI slot 1.
— Dell recommends installing the HBAs on separate PCI buses (PCI buses 2 and 3) to balance the load on the system.
— If you are currently using a DRAC 2 or plan to use one in the future, install it in PCI slot 2.