Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
Rev. A00
2014 - 11



Active System Manager (ASM) is Dell’s unified management product that provides a comprehensive infrastructure and workload automation solution for IT administrators and teams. ASM simplifies and automates the management of heterogeneous environments, enabling IT to respond more rapidly to dynamic business needs.
IT organizations today are often burdened by complex data centers that contain a mix of technologies from different vendors and cumbersome operational tasks for delivering services while managing the underlying infrastructure. These tasks are typically performed through multiple management consoles for different physical and virtual resources, which can dramatically slow down service deployment.
The new ASM features an enhanced user interface that provides an intuitive, end-to-end infrastructure and workload automation experience through a unified console. This speeds up workload delivery and streamlines infrastructure management, enabling IT organizations to accelerate service delivery and time to value for customers.
This document contains information about virtual appliance and software requirements of ASM, and the resources supported by ASM such as chassis, servers, storage, network switches, and adapters.
This document version is updated for ASM, version 8.0.
ASM online help system provides context-sensitive help available from every page in ASM user interface.

After you log in to ASM user interface, you can access the online help in any of the following ways:
Additionally, in the online help, use the Enter search items option in the Table of Contents to search for a specific topic or keyword.
Go to http://www.dell.com/asmdocs for additional supporting documents such as:
For more information about best practices, Dell solutions, and service, see Dell Active System Manager page on Dell TechCenter:
http://en.community.dell.com/techcenter/converged-infrastructure/w/wiki/4318.dell-active-system- manager.aspx
ASM licensing is based on the total number of managed resources, except for the VMware vCenter and Windows SCVMM instances
ASM 8.0 supports following license types:
You will receive an e-mail from customer service with the instructions for downloading ASM. The license file is attached to that email.
If you are using ASM for the first time, you must upload the license file through the Initial Setup wizard. To upload and activate subsequent licenses, click Settings → Virtual Appliance Management.
After uploading an initial license, subsequent uploads replace the existing license.
Engaging support requires that all prerequisites are fulfilled by customer or deployment team. Third party hardware support is not provided by Dell services. Discovery, inventory and usage of third party hardware must be in the expected state as described in the prerequisites and configuring sections of this guide.

The following ports and communication protocols used by ASM to transfer and receive data.
Table 1. ASM Port and Protocol Information

The following sections provide installation and quick start information, including step-by-step instructions for deploying and configuring ASM in VMware vSphere or Microsoft virtualization environment. Only one instance of ASM should be installed within a network environment. Exceeding this limit can cause conflicts in device communication.
Before you begin the installation process:
Before you begin, make sure that systems are connected and VMware vCenter Server, VMware vSphere Client, and SCVMM are running.
Connection Requirements • The virtual appliance is able to communicate with the out-of-band management network and any other networks from which you want to discover the resources.
Specification Prerequisite

Dell PowerEdge Servers • Dell PowerEdge Servers are configured and have the management IP address and login credentials assigned.
NOTE: The user name (root) and password required. • Any device being used in the boot order, such as C: Drive or NICs, must already be enabled in the boot order. This applies when booting to SD Card, Hard Disk, or FC, which are listed as C: in boot order or PXE and iSCSI, which are listed as NICs in the boot order. ASM will enable the supporting device connectivity and adjust the boot order, but cannot enable/disable device names in the boot order.
Dell PowerConnect 7024 switches • The management IP address is configured for the switches.
Dell Force10 S4810 switches (Top-of-Rack [ToR]) • The management IP address is configured for the ToR switches.
Specification Prerequisite

Dell PowerEdge M I/O Aggregator • Server facing ports must be in hybrid mode.
Dell Networking MXL 10/40GbE blade switch • Any VLAN which is dynamically provisioned by ASM must exist on the switch.
Dell 8 | 4 I/O modules • The management IP address is configured for the Brocade switches.
EqualLogic Storage Array • The management and group IP addresses are configured for Storage Array.
Compellent Storage Array .
VMware vCenter 5.1 or 5.5 • VMware vCenter 5.1 or 5.5 is configured and accessible through the management and hypervisor management network.
Specification Prerequisite

System Center Virtual Machine Manager (SCVMM) • See System Center Virtual Machine Manager (SCVMM) Prerequisites.
PXE Setup • Either use Active System Manager as the PXE responder by configuring through ASM user interface, by Getting Started page or follow instructions in Configuring ASM Virtual Appliance as PXE Responder.
The following table describes the prerequisites for the FCoE solution offered using M1000e (with MXL), S5000, and Compellent. For more information, see http://en.community.dell.com/techcenter/extras/m/ white_papers/20387203
MXL • DCB needs to be enabled.
interface range tengigabitethernet 0/33 – 36 port-channel-protocol lacp port-channel 128 mode active exit
protocol lldp no advertise dcbx-tlv ets-reco dcbx port-role auto-upstream no shut exit
interface port-channel 128 portmode hybrid switchport fip-snooping port-mode fcf
Specification Prerequisite · Conf Feature fip-snooping · portmode hybrid switchport

protocol lldp dcbx port-role auto-downstream no shut exit
S5000 Following is the prerequisite for S5000.
feature fc fc switch-mode fabric-services
interface range fi 0/0 - 7 no shut
dcb-map SAN_DCB_MAP priority-group 0 bandwidth 60 pfc off priority-group 1 bandwidth 40 pfc on priority-pgid 0 0 0 1 0 exit
fcoe-map default_full_fabric fabric- id vlan fc-map exit
For generating the fc-map use below ruby code.
Here VLAN ID is FCoE VLAN ID.
fc_map = vlanid.to_i.to_s(16).upcase[0..1] fc_map.length == 1 ? fc_map = "0EFC0#{fc_map}" : fc_map = "0EFC#{fc_map}"
Compellent Fault domain need to be created as per Compellent best practices.

The following table describes the prerequisites for the FCoE solution offered using Rack Server, S5000, and Compellent. For more information, see http://en.community.dell.com/techcenter/extras/m/ white_papers/20387203
S5000 • DCB needs to be enabled.
feature fc fc switch-mode fabric-services
interface range fi 0/0 - 7 no shut
dcb-map SAN_DCB_MAP priority-group 0 bandwidth 60 pfc off priority-group 1 bandwidth 40 pfc on priority-pgid 0 0 0 1 0 exit
interface vlan [Create VLAN for FCoE] exit
fcoe-map default_full_fabric fabric-id vlan fc-map exit
Compellent Fault domain need to be created as per Compellent best practices.
The following table describes the prerequisites for the FCoE solution offered using M1000e (with MXL), S5000, Brocade, and Compellent. For more information, see http://en.community.dell.com/techcenter/ extras/m/white_papers/20387203

MXL • DCB needs to be enabled.
interface range tengigabitethernet 0/33 – 36 port-channel-protocol lacp port-channel 128 mode active exit protocol lldp no advertise dcbx-tlv ets-reco dcbx port-role auto-upstream no shut exit
interface port-channel 128 portmode hybrid switchport fip-snooping port-mode fcf
portmode hybrid switchport protocol lldp dcbx port-role auto-downstream no shut exit
S5000 Below configuration is prerequisite for S5000.
interface range fi 0/0 - 7 no shut
dcb-map SAN_DCB_MAP priority-group 0 bandwidth 60 pfc off priority-group 1 bandwidth 40 pfc on priority-pgid 0 0 0 1 0 exit
conf Feature fip-snooping · feature fc

interface vlan [Create VLAN for FCoE] exit
fcoe-map default_full_fabric fabric-id vlan fc-map exit
interface fibrechannel 0/0 fabric default_full_fabric no shutdown
For generating the fc-map use below ruby code.
Here VLAN ID is FCoE VLAN ID
fc_map = vlanid.to_i.to_s(16).upcase[0..1] fc_map.length == 1 ? fc_map = "0EFC0#{fc_map}" : fc_map = "0EFC#{fc_map}"
Brocade Alias needs to be created having Compellent fault domain WWPN accessible on Brocade switch.
Compellent Nothing specific for ASM
The following table describes the prerequisites for the FCoE solution offered using Rack Server, S5000, Brocade and Compellent. For more information, see http://en.community.dell.com/techcenter/extras/m/ white_papers/20387203
S5000 • DCB needs to be enabled.
feature fc

interface range fi 0/0 - 7 no shut
dcb-map SAN_DCB_MAP priority-group 0 bandwidth 60 pfc off priority-group 1 bandwidth 40 pfc on priority-pgid 0 0 0 1 0 exit
interface vlan [Create VLAN for FCoE] exit
fcoe-map default_full_fabric fabric-id vlan fc-map exit
Brocade Alias needs to be created having Compellent fault domain WWPN accessible on Brocade switch.
Compellent Fault domain need to be created as per Compellent best practices.
The following table describes the prerequisites for the FCoE solution offered using M1000e (with MXL), Cisco Nexus, and Compellent. For more information, see http://en.community.dell.com/techcenter/ extras/m/white_papers/20387203
MXL • DCB needs to be enabled.
interface range tengigabitethernet 0/33 – 36
conf Feature fip-snooping

port-channel-protocol lacp port-channel 128 mode active exit
protocol lldp no advertise dcbx-tlv ets-reco dcbx port-role auto-upstream no shut exit
interface port-channel 128 portmode hybrid switchport fip-snooping port-mode fcf
portmode hybrid switchport protocol lldp dcbx port-role auto-downstream no shut exit
Cisco Nexus Following is the prerequisite for Cisco Nexus.
feature fcoe feature npiv feature lacp
conf vsan database vsan
vlan fcoe vsan

interface vfc101 bind mac-address 5C:F9:DD:16:EF:07 no shutdown
interface vfc102 bind mac-address 5C:F9:DD:16:EF:21 no shutdown
vsan 2 interface vfc101
vsan 2 interface vfc102
vsan 2 interface fc2/1
vsan 2 interface fc2/2
Compellent Create fault domain as per Compellent best practices.
The following table describes the prerequisites for the FCoE solution offered using Rack Server, Cisco Nexus and Compellent. For more information, see http://en.community.dell.com/techcenter/extras/m/ white_papers/20387203
Cisco Nexus Following is the prerequisite for Cisco Nexus.
feature fcoe feature npiv feature lacp
conf vsan database vsan
vlan fcoe vsan
Example · vsan database

interface vfc101 bind mac-address 5C:F9:DD:16:EF:07 no shutdown
interface vfc102 bind mac-address 5C:F9:DD:16:EF:21 no shutdown
vsan 2 interface vfc101
vsan 2 interface vfc102
vsan 2 interface fc2/1
vsan 2 interface fc2/2
Compellent Create fault domain as per Compellent best practices.
The following table describes the prerequisites for the FCoE solution offered using M1000e (with MXL), Cisco Nexus, Brocade, and Dell Compellent. For more information, see http://en.community.dell.com/ techcenter/extras/m/white_papers/20387203
MXL • DCB needs to be enabled.
For Example · vsan database · conf Feature fip-snooping

interface range tengigabitethernet 0/33 – 36 port-channel-protocol lacp port-channel 128 mode active exit
protocol lldp no advertise dcbx-tlv ets-reco dcbx port-role auto-upstream no shut exit
interface port-channel 128 portmode hybrid switchport fip-snooping port-mode fcf
portmode hybrid switchport protocol lldp dcbx port-role auto-downstream no shutdown exit
Cisco Nexus Following is the prerequisite for Cisco Nexus:
feature fcoe feature npiv feature lacp
conf vsan database vsan
vlan fcoe vsan
conf feature npv

interface vfc101 bind mac-address 5C:F9:DD:16:EF:07 no shutdown
interface vfc102 bind mac-address 5C:F9:DD:16:EF:21 no shutdown
vsan 2 interface vfc101
vsan 2 interface vfc102
vsan 2 interface fc2/1
vsan 2 interface fc2/2
Brocade Alias needs to be created having Dell Compellent fault domain WWPN accessible on Brocade switch.
Dell Compellent Nothing specific for ASM.
The following table describes the prerequisites for the FCoE solution offered using Rack Server, Cisco Nexus, Brocade, and Dell Compellent. For more information, see http://en.community.dell.com/ techcenter/extras/m/white_papers/20387203
Cisco Nexus Following is the prerequisite for Cisco Nexus:
For Example · vsan database

configuration. (Ensure to back up the configuration before enabling the feature).
feature fcoe feature npiv feature lacp
conf vsan database vsan
vlan fcoe vsan
For Example:
interface vfc101 bind mac-address 5C:F9:DD:16:EF:07 no shutdown
interface vfc102 bind mac-address 5C:F9:DD:16:EF:21 no shutdown
vsan 2 interface vfc101
vsan 2 interface vfc102
vsan 2 interface fc2/1
vsan 2 interface fc2/2
conf feature npv · vsan database

Brocade Alias needs to be created having Compellent fault domain WWPN, accessible on Brocade switch.
Dell Compellent Create fault domain as per Dell Compellent best practices.
The following table describes the prerequisites for the FCoE solution offered using M1000e (with MXL and FC FlexIOM), Brocade, and Dell Compellent. For more information, see http:// en.community.dell.com/techcenter/extras/m/white_papers/20387203
MXL • DCB needs to be enabled.
interface range tengigabitethernet 0/33 – 36 port-channel-protocol lacp port-channel 128 mode active exit
protocol lldp no advertise dcbx-tlv ets-reco dcbx port-role auto-upstream no shut exit
portmode hybrid switchport protocol lldp dcbx port-role auto-downstream no shut exit
Brocade Alias needs to be created having Dell Compellent fault domain WWPN accessible on Brocade switch.
conf feature fc

Dell Compellent Create fault domain as per Dell Compellent best practices.
ASM manages resource on Microsoft System Center Virtual Machine Manager through Windows Remote Management (WinRM). Windows RM must be enabled on the SCVMM server as well as on Active Directory and DNS servers used in SCVMM/HyperV deployments. ASM deployments support Active Directory and DNS servers which exist on the same machine. If Active Directory and DNS servers exist on separate machines, some manual tare-down may be required to remove host entries from the DNS server. ASM requires Windows RM to utilize default port and basic authentication. To enable these settings, on the SCVMM server and on the Active Directory and DNS server used in HyperV deployments, open a Windows PowerShell interface with administrator permissions and run the following commands:
winrm set winrm/config/client/auth '@{Basic="true"}' winrm set winrm/config/service/auth '@{Basic="true"}' winrm set winrm/config/service '@{AllowUnencrypted="true"}'
The default amount of memory allocated for WinRM processes is limited to 150 MB. To avoid out of memory errors, increase the memory size to 1024:
winrm set winrm/config/winrs '@{MaxMemoryPerShellMB="1024"}'
For Windows 2008:
Make sure the SCVMM has its time synchronized with time of the associated timer server. If the SCVMM timer is set to 'off' mode by using the deployed Hyper-V hosts, you cannot add hosts and create clusters in SCVMM.
winrm quickconfig

Click Next to continue.
Click Next to continue.
To deploy ASM using SCVMM:
a. In the left pane, click Library.
b. In the Home tab, click Import Physical Resource.
c. Click the Add Resource button. Browse to the location of ASM .vhd file: \Virtual Hard Disks\Dell-ActiveSystemManager-8.0-.vhd
d. Under the Select library server and destination for imported resources section, click the Browse button. Select the destination folder in which ASM install VHD is located (for example, My_SCVMM -> MSCVMMLibrary -> VHDs), and then click OK.
e. Click the Import button.
a. In the left pane, click VMs and Services.
b. Click the Create Virtual Machine button.
c. Select Use an existing virtual machine, VM template, or virtual hard disk, and then click the Browse button
d. From the list of sources, select VHD -> Dell-ActiveSystemManager-8.0- .vhd, and then click OK.
e. Click Next.
f. In the Virtual machine name text box, type the virtual machine name for your appliance, and then click Next.
g. On the Configure Hardware page, do the following:

h. On the Select Destination page, select the destination host group that contains the Hyper-V server where you want to deploy ASM VM. Click Next.
i. On the Select Host page, select the host on which you want to deploy ASM, and then click Next.
j. On the Configuration Settings page, make the changes for your environment, if required.
k. On the Select networks page, select your PXE network and configure it appropriately.
l. On the Add Properties page, set to Always turn on the Virtual Machine and the OS as CentOS Linux (64 bit), and then click Next.
m. Review the summary, select the Start Virtual machine after deploying it option, and then click the Create button.
Deploying ASM on Hyper-V host
To deploy ASM on Hyper-V host:

You must configure the following settings in the virtual appliance console before you start using ASM:
To change “delladmin” password:

ASM requires both PXE and DHCP network services to function. ASM may be configured to act as the DHCP server and PXE responder on a PXE network if one is not present in the environment. This can be configured through the Getting Started menu for appliance setup in the ASM user interface. If an external DHCP or PXE server is used for the PXE network, follow the instructions in the section Configuring DHCP or PXE on External Servers.

ASM supports cloning virtual machines (VM) or virtual machine templates in VMware, and cloning virtual machine templates in Hyper-V. For ASM virtual machine or virtual machine template cloning, the virtual machine or virtual machine templates must be customized to make sure virtual machine or virtual machine templates have a unique identifier and can communicate back to the ASM appliance upon completion of the cloning process. This requires several customizing steps that depends on virtual machine which is needed to be cloned.
ASM can clone existing virtual machines and virtual machine templates in vCenter, or virtual machine templates in Hyper-V. The source virtual machines and virtual machine templates must be customized according to the instructions provided in this section. After customization, you must shut down the virtual machine and you cannot restart the virtual machine. For VMware virtual machines or virtual machine templates, cloning is supported as long as you are cloning within the same datacenter. For SCVMM the virtual machine templates must exist in the SCVMM library. Cloning virtual machines directly is not currently supported for Hyper-V.
The following customization is required only for VMware virtual machines:
Install VMWare Tools on the virtual machine:
The following customization is required for both VMWare and Hyper-V virtual machine
Install the puppet agent on the virtual machine:

in /var/lib/razor/repo-store directory. If the virtual machine being customized has network access to the ASM appliance, you can connect to this same directory as a network share directory using the address: \\\razor\puppet-agent .
Depending on your operating system, the installer may require additional packages (.rpms) which are dependencies and you must install it first. If the installer reports such dependencies, use the correct method for your operating system to find and install the dependencies, and then retry installation of the puppet agent.
– For Windows virtual machines, this must be done by viewing the services and setting the puppet agent service to "automatic".
– For Linux virtual machines, verify whether or not the puppet agent is enabled by running the following command and checking the value of "enable" is set to true:
Puppet resource service puppet
– If the service is not set to true as noted above, run the following puppet command as administrator:
puppet resource service puppet enable=true
– Identify the location of the puppet.conf file. To do this, run the following command as "administrator" in Windows or "root" in Linux which will display the directory of the puppet.conf file.
puppet config print config
– Open the puppet.conf file by using a text editor and add the line "server = dellasm" to the [main], [master], and [agent] section. If any of these sections does not exist, create them. A sample resulting puppet.conf file may look similar to the following: [main] server=dellasm [master] server=dellasm [agent] server=dellasm

Perform the following task to customize Linux template:
a. Install VMware tools (VMware only) b. Install puppet agent and ensure it is configured to run on startup c. Make sure ASM appliance and virtual machine time are synchronized by NTP. d. Make sure DNS is configured for “dellasm” to resolve. e. Make sure puppet.conf file has updated configuration to point to “dellasm” as server.
a. You can find the puppet certificate name scripts for Linux (puppet_certname.sh and ppet_certname.rb) in /opt/asm-deployer/scripts on ASM appliance. You can move these files to /var/lib/razor/repo-store. The ASM appliance location /var/lib/razor/repo-store is a share that can be mounted to your virtual machine if the virtual machine has network connectivity to the ASM appliance
b. On a Linux virtual machine, you must copy these scripts to /usr/local/bin. Make sure the
permissions are set on these scripts to at least read and execute. To do this, run the following commands: chmod 755 /usr/local/bin/puppet_certname.sh chmod 755 /usr/local/bin/puppet_certname.rb
RHEL/CentOS:
rm /etc/udev/rules.d/70-persistent-net.rules rm/lib/udev/rules.d/75-persistent-net-generator.rules sed -i "/^HWADDR/d" /etc/sysconfig/network-scripts/ifcfg-eth0
Debian/Ubuntu:
rm /lib/udev/rules.d/75-persistent-net-generator.rules
Type the following commands:
a. Add the following line to this file and then save and exit the file. @reboot /usr/local/bin/puppet_certname.sh; /etc/init.d/puppet restart
crontab –e

b. Run the following command, and ensure that you see the above line, to verify the crontab is
updated as expected or not, crontab -l
Perform the following task to customize Linux template.
a. Install VMware tools (VMware only) b. Install puppet agent and ensure it is configured to run on startup c. Make sure ASM appliance and virtual machine time are synchronized by NTP. d. Make sure DNS is configured for “dellasm” to resolve. e. Make sure puppet.conf file has updated configuration to point to “dellasm” as server
a. You can find the puppet certificate name scripts for Windows (puppet_certname.bat and ppet_certname.rb) in /opt/asm-deployer/scripts on ASM appliance. You can move these files to /var/lib/razor/repo-store. The ASM appliance location /var/lib/razor/repo-store is a share that can be mounted to your virtual machine if the virtual machine has network connectivity to the ASM appliance.
b. On a Windows virtual machine, you must copy these scripts to “C:\”


For ASM to support NetApp, perform the following tasks:
Make sure license is enabled for NFS on NetApp. To obtain and install the license, refer NetApp documentation.
NetApp Manageability SDK is available to download directly from NetApp. You need a NetApp NOW account to download the SDK.
NaServer.patch file is available on the ASM appliance at location /etc/puppetlabs/puppet/module/netapp/ files/NaServer.patch

sudo patch /etc/pupetlabs/puppet/modules/netapp/lib/puppet/util/ network_device/netapp/NaServer.rb < /tmp/NaServer.patch
sudo chmod 755 /etc/puppetlabs/puppet/modules/netapp/lib/puppet/util/ network_device/netapp/*
sudo chown pe-puppet:pe-puppet /etc/puppetlabs/puppet/modules/netapp/lib/ puppet/util/network_device/netapp/*
Connect to the NetApp Filer using ssh and run the option httpcommand to see the current settings. If the property httpd.admin.ssl is set to off, then run the command option httpd.admin.ssl.enable on to enable HTTPS.
ADC-NetApp01> options http httpd.access legacy httpd.admin.access legacy httpd.admin.enable on httpd.admin.hostsequiv.enable on httpd.admin.max_connections 512 httpd.admin.ssl.enable on httpd.admin.top-page.authentication on httpd.autoindex.enable on httpd.bypass_traverse_checking on httpd.enable on httpd.ipv6.enable off httpd.log.format common(value might be overwritten in takeover) httpd.method.trace.enable off httpd.rootdir /vol/vol0/home/http httpd.timeout 300(value might be overwritten in takeover) httpd.timewait.enable off(value might be overwritten in takeover ADC-NetApp01>
The following settings must be configured in the NetApp storage component.
For more information about NetApp Storage Component, see Active System Manager version 8.0 User’s Guide.


Log in to ASM using the appliance IP address, After logging into ASM, you need to complete the basic configuration setup in the Initial Setup wizard. For more information about completing the initial setup, see the Active System Manger Version 8.0 User’s Guide.



You need to perform the following configuration tasks before using ASM to deploy Windows OS.
1. Create a Windows .iso that has been customized for use with ASM using ADK and build-razor- winpe.ps1 script. You will need to locate the appropriate drivers for your server hardware or virtual machines for the operating system you are trying to install. For Dell hardware, drivers can be obtained from support.dell.com. For other vendors such as VMware, follow the instructions from the manufacturer to locate the correct drivers. During .iso customization it will be updated to include the drivers required for VMware virtual machine VMXnet3 NICs, any other drivers specific to your hardware, and customizations for use with ASM. This will allow you to support operating system deployment through ASM of Windows 2008 R2, Windows 2012, or Windows 2012 R2 to virtual machines or bare-metal servers. For more information see, Creating WinPE Image and Updating Install Media for Windows 2008 R2, Windows 2012 and Windows 2012 R2
Creating WinPE Image and Updating Install Media for Windows 2008 R2, Windows 2012 and Windows 2012 R2
You should have Windows Assessment and Deployment toolkit that contains the Windows PE environment used to automate the Windows installer installed in the DEFAULT location on a Windows machine. Licensing for Windows PE requires that you build your own customized WinPE WIM image containing the required scripts.
To create customized Windows.iso image for Windows 2008 R2, Windows 2012 and Windows 2012 R2:

For example:
powershell -executionpolicy bypass -noninteractive -file build-razor- winpe.ps1 192.168.0.1 Windows2012r2.iso ASMWindows2012r2.iso
NOTE: If the build script fails or is stopped during execution it may be necessary to clean up files in the build directory before executing again. In some cases, directories may still be mounted and require cleanup. To clean up, delete all files other than the necessary script, starting .iso, and Drivers folder. If any files cannot be deleted, try executing the following commands from a command prompt in the build folder location:C:\buildpe>dism / cleanup-wim
You can add one or more OS image repositories in ASM GUI.
To add an OS image repository, perform the following tasks in the ASM GUI:

a. In the Repository Name box, enter the name of the repository.
b. In the Image Type box, enter the image type.
c. In the Source File or Path Name box, enter the path of the OS Image file name in a file share.
d. If using a CIFS share, enter the User Name and Password to access the share. These fields are only enabled when entering a CIFS share.
For more information about firmware repositories, see ASM Online Help.



The PXE service requires a DHCP server configured to provide boot server (TFTP PXE server) information and specific start-up file information. ASM PXE implementation uses the iPXE specification so that the configuration details include instructions to allow legacy PXE servers and resources to boot properly to this iPXE implementation.
This section provides information about configuring DHCP on the following servers. The information includes only the basic configuration options and declarations required for an iPXE environment. These details should be used as a cumulative addition to the settings currently used in your DHCP implementation (if you already have a DHCP environment).
To configure the DHCP on Windows 2012 DHCP Server, perform the following tasks:
For additional information, see http://ipxe.org/howto/msdhcp
You must create the user class for the DHCP server before creating the DHCP Policy.
a. In the Display Name box, enter iPXE
b. In the Description box, enter iPXE Clients
c. In the data pane, under ASCII, enter iPXE

The DHCP Policy Configuration Wizard is displayed.
To configure the DHCP on Windows 2008 DHCP Server, perform the following tasks:
For additional information, see http://ipxe.org/howto/msdhcp

Create the DHCP User Class
You must create the user class for the DHCP server before creating the DHCP Policy.
a. In the Display Name box, enter iPXE.
b. In the Description box, enter iPXE Clients.
c. In the data pane, under ASCII, enter iPXE.
Create the DHCP Policy
Use the new User Class to create a DHCP policy scope option.
The policy is created by utilizing the new User Class with a scope option.
Create the Boot File Scope Option
The Boot File option is created for the DHCP scope that services your ASM PXE.

You can manage the configuration of the Linux DHCPD service by editing the dhcpd.conf configuration file. The dhcpd.conf is located at /etc/dhcp directory of most Linux distributions. If the DHCP is not installed on your Linux server, install the Network Infrastructure Server or similar services.
Before you start editing the dhcpd.conf file, it is recommended to back up the file. After you install the appropriate network services, you must configure the dhcpd.conf file before you start the DHCPD service.
The DHCP configuration must include the following options:
Indicates the IP address of the PXE server. That is, the IP address of ASM appliance vNIC that exists on the PXE network.
The PXE service uses iPXE service. You must use two different bootstrap files for the PXE environment, one for the initial PXE boot, which starts up the system to the final iPXE boot file.
To run this operation, add the following code to the dhcpd.conf file:
if exists user-class and option user-class = "iPXE" { filename "bootstrap.ipxe"; } else { filename "undionly.kpxe"; }
Secondly, add the following code to the subnet declaration within your dhcpd.conf file. This code instructs a legacy PXE server to boot to a legacy boot file, and then directs to the iPXE boot file. For more details, see the Sample DHCP Configuration
The configuration file must contain the following information:
# dhcpd.conf # Sample configuration file for ISC dhcpd next-server 192.168.123.21;# IP address of ASM Server default-lease-time 6000; max-lease-time 7200; authoritative; log-facility local7;
subnet 192.168.123.0 netmask 255.255.255.0 { range 192.168.123.24 192.168.123.29; option subnet-mask 255.255.255.0; option routers 192.168.123.1; if exists user-class and option user-class = "iPXE" { filename "bootstrap.ipxe"; } else { filename "undionly.kpxe"; } }

After you modify the dhcpd.conf file based on your environment, you need to start or restart your DHCPD service. For more information, see http://ipxe.org/howto/dhcpd
# dhcpd.conf # # Sample configuration file for ISC dhcpd # #option definitions common to all supported networks... #option domain-name "example.org"; #option domain-name-servers 192.168.203.46;
#filename "pxelinux.0"; next-server 192.168.123.21;# IP address of ASM Server
default-lease-time 6000; max-lease-time 7200;
# Use this to enble / disable dynamic dns updates globally. #ddns-update-style none;
# If this DHCP server is the official DHCP server for the local # network, the authoritative directive should be uncommented. authoritative;
# Use this to send dhcp log messages to a different log file (you also have to hack syslog.conf to complete the redirection. log-facility local7;
# No service will be given on this subnet, but declaring it helps the # DHCP server to understand the network topology.
#subnet 192.168.123.0 netmask 255.255.255.0 { #}
# This is a very basic subnet declaration.
subnet 192.168.123.0 netmask 255.255.255.0 { range 192.168.123.24 192.168.123.29; option subnet-mask 255.255.255.0; option routers 192.168.123.1; if exists user-class and option user-class = "iPXE" { filename "bootstrap.ipxe"; } else { filename "undionly.kpxe"; } }
# This declaration allows BOOTP clients to get dynamic addresses, # which we don't really recommend.
Sample DHCP Configuration

#subnet 10.254.239.32 netmask 255.255.255.224 { #range dynamic-bootp 10.254.239.40 10.254.239.60; #option broadcast-address 10.254.239.31; #option routers rtr-239-32-1.example.org; #}
#A slightly different configuration for an internal subnet. #subnet 10.5.5.0 netmask 255.255.255.224 { #range 10.5.5.26 10.5.5.30; #option domain-name-servers ns1.internal.example.org; #option domain-name "internal.example.org"; #option routers 10.5.5.1; #option broadcast-address 10.5.5.31; #default-lease-time 600; #max-lease-time 7200; #}
# Hosts which require special configuration options can be listed in # host statements. If no address is specified, the address will be # allocated dynamically (if possible), but the host-specific information # will still come from the host declaration.
#host passacaglia { # hardware ethernet 0:0:c0:5d:bd:95; # filename "vmunix.passacaglia"; # server-name "toccata.fugue.com"; #}
# Fixed IP addresses can also be specified for hosts. These addresses # should not also be listed as being available for dynamic assignment. # Hosts for which fixed IP addresses have been specified can boot using # BOOTP or DHCP. Hosts for which no fixed address is specified can only # be booted with DHCP, unless there is an address range on the subnet # to which a BOOTP client is connected which has the dynamic-bootp flag # set. #host fantasia { # hardware ethernet 08:00:07:26:c0:a5; # fixed-address fantasia.fugue.com #}
# You can declare a class of clients and then do address allocation # based on that. The example below shows a case where all clients # in a certain class get addresses on the 10.17.224/24 subnet, and all # other clients get addresses on the 10.0.29/24 subnet.
#class "foo" { # match if substring (option vendor-class-identifier, 0, 4) = "SUNW"; #}
#shared-network 224-29 { #subnet 10.17.224.0 netmask 255.255.255.0 { #option routers rtr-224.example.org; # } # subnet 10.0.29.0 netmask 255.255.255.0 { # option routers rtr-29.example.org; # }

# pool { # allow members of "foo"; # range 10.17.224.10 10.17.224.250; # } # pool { # deny members of "foo"; # range 10.0.29.10 10.0.29.230; # } #}