Instruction/ maintenance manual of the product V-50 Dansons Group
Go to page of 40
.
Can adian Comfort Industries V05 2 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. Dear VULCAN “V” SERIES Pellet Stove Owner: CONGRATULATIONS on the purchase of your VULCAN “V” SERIES wood pellet appliance! You have selected the finest in residential wood pellet heating technology.
Can adian Comfort Industries V05 3 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. T ABLE OF C ONTENTS GENERAL INFORMATION SAFETY PR ECAUTION S ----------------------------------.
Can adian Comfort Industries V05 4 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. S AFETY P RECAUTIONS IMPORTANT : Read, save and follow the instructions in this manual. It contains important Safety, Operating and Maintenance instructions you will need.
Can adian Comfort Industries V05 5 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. S AFETY P RECAUTIONS . . . Continued • DO NOT operate the stove if the flame becom es dark and sooty or if the firepot overfills with pellets. Push the OFF Touch Pad and inspect the heater.
Can adian Comfort Industries V05 6 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. H OW Y OUR S TOVE W ORKS The operations and maintenance of your VULCAN “V” SERIES stove are unique and should not be considered to be like a wood, coal stov e, gas, electric, propane or oil heater.
Can adian Comfort Industries V05 7 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. A UTOMATIC S AFETY F EATURES L120 LOW LIMIT SWITCH This limit switch is mounted on the exhaust blower housing and has 2 main functions.
Can adian Comfort Industries V05 8 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. S PECIFICATIONS HEATING SPECIFICATIONS Approx. Heating capacity (sq. feet) * 800 – 2,000 Approx. Fuel burn rate per hour ** 1.5 – 5 lbs Hopper Capacity - Traditional Stove / Insert 40 lb s Approx.
Can adian Comfort Industries V05 9 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. P LANNING & I NSTALLATION C HECK L IST Unless you are knowledgeable and experienced in stov.
Can adian Comfort Industries V05 10 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. I NSTALLATION O PTIONS READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR VULCAN “V” SERIES HEATER.
Can adian Comfort Industries V05 11 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. E XHAUST S YSTEMS ( GENERAL ) PELLET VENT MUST MAINTAIN A MINIMUM 3” CLEARANCE TO ANY COMBUSTIBLE (INSTA LL VENT AT CLEA RANCES SPECIFIED BY THE VENT MA NUFACTURER).
Can adian Comfort Industries V05 12 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. E XHAUST S YSTEMS . . . Continued PELLET VENT TERMINATION: (Figures 7 & 8) Termination mus.
Can adian Comfort Industries V05 13 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. O UTSIDE A IR Outside air is REQUIRED ON ALL MOBILE HOME INSTALLATIONS .
Can adian Comfort Industries V05 14 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. F REESTANDING S TOVE I NSTALLATION STOVE PLACEMENT: Stove must be placed so that no combustibles are within, or can swing within (i.e. drapes doors), 36” of the heater.
Can adian Comfort Industries V05 15 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. F REESTANDING I NSTALLATION . . . continued CLEARANCES – “CORNER INSTALLATION”: Figure 12 Figure 13 Note: If interior vertical vent is used, the clear ance to the back wall is determined by the upward-turned elbow or “Tee”.
Can adian Comfort Industries V05 16 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. F REESTANDING I NSTALLATION . . . continued Figure 16 NOTE: Some horizontal, through the wall installations may require a Clean-Out Tee and a minimum 3’ vertical rise of pipe inside or outside the building to help draft the stove.
Can adian Comfort Industries V05 17 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc..
Can adian Comfort Industries V05 18 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. M OBILE H OME I NSTALLATION CAUTION: DO NOT INSTALL STOVE IN SLEEPING ROOM THE STRUCTURAL INTE.
Can adian Comfort Industries V05 19 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. F IREPLACE I NSERT I NSTALLATION VENTING INTO AN EXISTING CHIMNEY: CAUTION: MAKE SURE THE CHIMNEY AND FIREBOX ARE CL EAN AND FREE OF SOOT AND ASHES BEFORE INSTALLATION BEGINS.
Can adian Comfort Industries V05 20 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. F IREPLACE I NSERT I NSTALLATION … CONTINUED When installing into a masonry chimney, it is reco mmended that the exhaust vent be extended to the top of the chimney as shown to the lower right.
Can adian Comfort Industries V05 21 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc..
Can adian Comfort Industries V05 22 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. B UILT -I N I NSERT I NSTALLATION . . . CON ’ T PELLET VENT MUST MAINTAIN A MINIMUM 3” CLEARANCE TO ANY COMBUSTIBLE (INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER).
Can adian Comfort Industries V05 23 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. L IGHTING Y OUR S TOVE Before lighting a fire check to ensure the Burn Gr ate is clean and adjusted and the Ash Tray is not full.
Can adian Comfort Industries V05 24 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc..
Can adian Comfort Industries V05 25 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. T HE C ONTROLS … CONTINUED TRIM POTS (Fine Tune Adjustments) – Factory Settings The COMBUS.
Can adian Comfort Industries V05 26 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. Wall Thermostat (option) OPERATION Your pellet appliance is capable of running in an aut omatic mode with the use of the optional “Wall Thermostat Add-On Kit”.
Can adian Comfort Industries V05 27 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. I NITIAL A PPLIANCE B URN S ETUP IT IS CRITICAL FOR THE CORRECT O PERATION OF YOUR STOVE THAT .
Can adian Comfort Industries V05 28 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. P ERFORMANCE E NHANCEMENT T IPS Quality care and quality pellets will help your stove operate at it s peak efficiency. Consider: If any fines are noticed in the pellets or in the hopper, you may wish to screen the pellets.
Can adian Comfort Industries V05 29 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. P ELLET F UEL The performance of your pellet appliance is greatly affected by the type and quality of wood pellets burned. As the heat output of various quality wood pellets differ, so will the performance and heat output of your appliance.
Can adian Comfort Industries V05 30 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. A SH AND C LINKERS …. CONTINUED CLINKERS are those solid, glassy or porous accumulations that may result from burning some types of wood pellets.
Can adian Comfort Industries V05 31 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. CLEANING YOUR SUPER GRATE INSERTING, REMOVING & ADJUSTING THE BURN GRATE The burn grate top, (D), must fit and seal firml y on the upper lips, of t he burn box, (A).
Can adian Comfort Industries V05 32 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. R EQUIRED R OUTINE C LEANING Proper care of your VULCAN “V” SERIES pellet appliance is required for peak, sustained performance.
Can adian Comfort Industries V05 33 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. P ERIODIC M AINTENANCE SOOT - FLY ASH: T he by products of combustion contain sma ll particles of fly ash. Fly ash will collect in the exhaust venting system and restrict the flow of flue gases.
Can adian Comfort Industries V05 34 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. P ERIODIC M AINTENANCE … CONTINUED INSPECT AND CLEAN THE CHIMNEY: [ELECTRICAL CORD UNPLUGGED] Under some conditions fly ash build up in the chimney system may o ccur rapidly.
Can adian Comfort Industries V05 35 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. T ROUBLE S HOOTING Proper cleaning, maintenance and the use of quality pellets will prevent the more common stove operational problems.
Can adian Comfort Industries V05 36 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. L IMITED W ARRANTY The VULCAN “V” SERIES wood pellet appliance, carries a five (5) year li.
Can adian Comfort Industries V05 37 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. A PPENDIX “A” OPTIONAL ACCESSORIES Description Model Doors c/w neo-ceramic glass - Brass Trim APDRGAS Grate - "Super Grate" ACSUGR Hearth Extension ACHEEX Hopper Extension - 6" high (approx.
Can adian Comfort Industries V05 38 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. Appendix “B” REPLACEMENT PARTS D escr i pt i on M odel A ir D e fl e c tor A i r D ef l ec.
Can adian Comfort Industries V05 39 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. REPLACEMENT PARTS …continued Contact your local Specialty Retailer, Certified HVAC Service Depot, or Dansons Group Inc. Customer Service Department at 1-866-456-9269 for additional information.
Can adian Comfort Industries V05 40 VULCAN “V” SERIES OWNERS MANUAL Copyright 2005 Dansons Group Inc. D EA LER : P URCHA SER ’ S N AM E : A DDRESS : A DDRESS : C ITY : S TA TE /P ROV : C ITY : S.
An important point after buying a device Dansons Group V-50 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Dansons Group V-50 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Dansons Group V-50 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Dansons Group V-50 you will learn all the available features of the product, as well as information on its operation. The information that you get Dansons Group V-50 will certainly help you make a decision on the purchase.
If you already are a holder of Dansons Group V-50, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Dansons Group V-50.
However, one of the most important roles played by the user manual is to help in solving problems with Dansons Group V-50. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Dansons Group V-50 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center