Page 1
IVS1, IVS2, IVSR1, IVSR2 PLANNING
Integrated Ventilation System
1/1 Revised 08/04/08 GUIDE
8" (203mm) round exhaust with back draft damper
8" (203mm) round exhausts with back draft damper
Fig. 1 · 1/1 Revised 08/04/08 Fig. 2 · 1/1 Revised 08/04/08 CL CL CL Fig. 3 Fig. 4 NOTES: 1. An internal blower is included with model IVS1 and IVS2. Blower Ratings: 1200CFM for IVS2 and 600CFM for IVS1. 2. Remote blower is required for IVSR1/IVSR2 models. 3. The ATD10 is sold seperately.
(For use with IVS2 and IVSR2)
Fig. 5
Model No.Dedicated Circuit RequiredMaximum Duct LengthTotal Connected LoadApproximate Shipping Weight
IVS1120 Vac, 60 Hz, 15 Amp Min. grounded, dedicated circuitMaximum 60 Equivalent Straight Feet0.2 kW (2 Amp)25 lbs.
IVSR10.2 kW (1.5 Amp)*21 lbs.
IVS20.4 kW (3 Amp)38 lbs.
IVSR20.2 kW (1.5 Amp)*29 lbs.
* Does not include remote blower
Web http://www.Dacor.com Corporate Phone: 800-793-0093
Specifications are subject to change without notice. See installation instructions for additional details. 7.14
Show 8 more labels / short text on this page IVS1/IVSR1 overall dimensions · IVS2/ivsR2 overall dimensions · 8" Exhaust · IVS1/ivsR1 overall dimensions · IVS2/ivsR2 overall dimensions · (Top View) · (Top View) · ATD10 Overall dimensions