COMBINATION INSTALLATIONS

Document # PGCI-026 Revised 12/07/11 Page 1/1

Dacor ERV3015 — COMBINATION INSTALLATIONS diagram (page 1)
Fig. 1
  • Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
  • All appliances must be installed in accordance with the accompanying installation instructions. Cutout tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated

On installations with a raised vent, when sliding the range into position, it will stop when the rear of the side panels or control panel contacts the notches toward the front of the countertop. The rear range trim will partially cover the front of the raised vent chassis in back.

Dacor ERV3015 — COMBINATION INSTALLATIONS diagram (page 1)
Fig. 2
Dacor ERV3015 — COMBINATION INSTALLATIONS diagram (page 1)
Fig. 3

2 9/16” (6.5 cm)

Dacor ERV3015 — COMBINATION INSTALLATIONS diagram (page 1)
Fig. 4
DR30DI with Raised Vent Installed Side PanelsABC Installed 20 5/8” (52.4 cm)0” (0 cm) to 3 1/4” (8.3 cm)0” (0 cm) to 5 3/8” (13.7 cm) Removed 23 7/8” (60.6 cm)0” (0 cm)0” (0 cm) to 2 1/8” (5.4 cm)

below countertop To cabinet face To countertop

Countertop HeightMin: 35 7/16” (90.0 cm) Max: 37 1/4” (94.6 cm)

Top View - Model DR30DI Counter/Cabinet Cutout Dimensions

Self-Rimming Installation with ERV3015 Raised Vent

Dacor ERV3015 — Top View - Model DR30DI Counter/Cabinet Cutout Dimensions diagram (page 1)
Fig. 5 · Top View - Model DR30DI Counter/Cabinet Cutout Dimen…

3/8” min. (1.0 cm) flat countertop overhang required behind cutout

3/8” min. (1.0 cm) space behind raised vent chassis to clear stiffener

Countertop height: 35 7/16" (90.0 cm) min. 37 1/4” (94.6 cm) max.

* IMPORTANT: See Countertop/Cabinet Cutout Dimensions for countertop cutout dimensions.

** IMPORTANT: If 3 1/4 inch side panels are removed cabinet face cabinet face must be flush with back of control panel.

dimensions - model DR30DI with ERV3015 Raised Vent

All specifications subject to change without notice. Phone: (800) 793-0093 www.dacor.com

front · ERV3015 raised vent

Ask about the Dacor ERV3015

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Dacor ERV3015

Be the first to ask — other owners or our team will answer.

Original document

Dacor ERV3015 manual PDF

1 pages·307 KB·Ventilation Hood·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…