EN
Dacor logo
Official user manual

Dacor DR30GFS

5 pages·695 KB·Ventilation Hood·PDF·ENDEFRITNLJA
Dacor DR30GFS
Table of Contents 4 sections Self-Rimming Installation, custom Cutout Options (Models DR30GIS and DR30GIFS Only) · Raised Vent (Self-Rimming) Installation Cutout Options (Models DR30GIS and DR30GIFS Only) · Self-Rimming Installation, Standard Cutout Requirements (Models DR30GIS and DR30GIFS Only) · Electrical Specifications/Dimensions, All Models ShowHide
Page 1 of the Dacor DR30GFS user manual
Page 1 · click to enlarge
Page 1
Dacor DR30GFS diagram (page 1)
Fig. 1
  • Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
  • This appliance must be installed in accordance with the accompanying installation instructions.

28 9/16” (72.5 cm) Front of knobs 28” (71.1 cm)

DR30GI[F]S3 1/2” (8.9 cm) partial stainless steel side panels

Overall Depth Dimensions - side view

Part NumberDescriptionCompatibility AER30GLBGLow profile (1 3/4 inch)Standard on models DR30GIS, DR30GIFS Optional on models DR30GS, DR30GFS AERB30G033 InchOptional on models DR30GS, DR30GFS NOT compatible with models DR30GIS, DR30GIFS AERB30G066 InchStandard on models DR30GS, DR30GFS NOT compatible with models DR30GIS, DR30GIFS AERB30G099 InchOptional on models DR30GS, DR30GFS NOT compatible with models DR30GIS, DR30GIFS
Dacor DR30GFS diagram (page 1)
Fig. 2

All specifications subject to change without notice. Phone: (800) 793-0093 www.dacor.com

Available Backguards

Page 2 of the Dacor DR30GFS user manual — A
Page 2 · click to enlarge
Page 2

B

  • Failure to meet or exceed the maximum and minimum dimensions/clearances stated may result in a fire hazard.
  • The range should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets.
  • To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above surface units should be avoided. If cabinet storage space is to be provided directly above the range, the risk of personal injury may be reduced by installing a range hood.
Dacor DR30GFS — B diagram (page 2)
Fig. 3

13” (33.0 cm) max.4

Back wall immediately behind range6

  • In all instances, installation of a range hood is highly recommended. The hood should project horizontally a minimum of five (5) inches beyond the face of the cabinets. See the range hood specifications for minimum clearances.

Top of finished counter

Suggested location of utilities3

  • If installing a raised vent, install only Dacor model ERV3015.

14” (35.6 cm) min.4

A

  • The range may be installed flush to the rear wall. See diagram and notes for rear wall surface requirements. It is not necessary to install noncombustible materials behind the range below the countertop height.
  • Any openings in the wall behind the appliance or in the floor underneath it must be sealed.
A*BC 30” min. (76.2 cm)36” (91.4 cm) recommended 30” (76.2 cm) min.37” (94.0 cm) max.

* See the cutout dimensions on following page for self-rimming installations.

Freestanding Installation Cabinet Cutout Dimensions - Models DR30GS, DR30GFS, DR30GIS and DR30GIFS

1 30” (76.2 cm) min. vertical clearance from top of range grates to bottom of uncovered wood or metal cabinet. 24” (61 cm) min. clearance if bottom of wood or metal cabinets are protected by not less than 1/4“ (0.6 cm) flame retardant millboard covered with no less than No. 28 MSG sheet steel 0.015” (0.04 cm) stainless steel, or 0.024” (0.06 cm) aluminum or 0.020” (0.05cm) copper. 30” (76.2 cm) min. clearance between top of range grates and bottom of unprotected wood or metal cabinet. If installing range hood, check the hood specifications for minimum required clearances.

2 Cabinet/countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel. See Product Dimensions.

3 Consult local code and following pages for requirements.

4 This specification not applicable for cabinets more than a horizontal distance of 10” (25.4 cm) from edge of range.

5 10” (25.4 cm) min. to combustible sidewalls above range (both sides).

6 Non-combustible surface required for models DR30GIS and DR30GIFS up to vertical distance specified in note 1 or range hood, whichever is lower. Non- combustible surface recommended, but not required, for models DR30GS and DR30GFS.

All specifications subject to change without notice. Phone: (800) 793-0093 www.dacor.com

Page 3 of the Dacor DR30GFS user manual — Self-Rimming Installation, custom Cutout Options (Models DR30GIS and DR30GIFS Only)
Page 3 · click to enlarge
Page 3

Self-Rimming Installation, custom Cutout Options (Models DR30GIS and DR30GIFS Only)

For all self-rimming installations: Countertop height: 34 3/4” (88.3 cm) min. 36 7/8” (93.7 cm) max. Countertop thickness: 1 5/8” (4.1 cm) max.

10” min. (25.4 cm) to any combustibles above counter both sides

10” min. (25.4 cm) to any combustibles above counter both sides

Non-combustible rear wall required

Rear wall or countertop edge

3/4” min. (1.9 cm) countertop overhang

Dacor DR30GFS — Self-Rimming Installation, custom Cutout Options (Models DR30GIS and DR30GIFS Only) diagram (page 3)
Fig. 4 · Self-Rimming Installation, custom Cutout Options (Mo…
Dacor DR30GFS — Self-Rimming Installation, custom Cutout Options (Models DR30GIS and DR30GIFS Only) diagram (page 3)
Fig. 5 · Self-Rimming Installation, custom Cutout Options (Mo…

20 3/4” (52.7 cm) 25 5/8” max. (65.1 cm)

Cabinet Depth Greater Than 24” 2 3 1/4” Side Panels Installed, Range Back Overhanging Countertop (Top View)

Cabinets Less Than 24” Deep, 3 1/4” Side Panels Installed, Range Back Flush to Wall (Top View)

10” min. (25.4 cm) to any combustibles above counter both sides

Non-combustible rear wall required

10” min. (25.4 cm) to any combustibles above counter both sides

Rear wall or countertop edge

1” min. (2.5 cm) Countertop overhang

Dacor DR30GFS — Self-Rimming Installation, custom Cutout Options (Models DR30GIS and DR30GIFS Only) diagram (page 3)
Fig. 6 · Self-Rimming Installation, custom Cutout Options (Mo…
Dacor DR30GFS — Self-Rimming Installation, custom Cutout Options (Models DR30GIS and DR30GIFS Only) diagram (page 3)
Fig. 7 · Self-Rimming Installation, custom Cutout Options (Mo…

1 5/8” (4.1 cm) max.

1 5/8” (4.1 cm) max.

Cabinet Exactly 24” Deep, 3 1/4” Side Panels Removed, Range Back Flush to Wall (Top View)

Cabinet Depth Greater Than 25 1/8” 2 3 1/4” Side Panels Removed, Range Back Overhanging Countertop (Top View)

1 On models DR30GIS and DR30GIS, non-combustible surface required immediately behind range, as specified on previous page, when back of backguard is less than 2 1/2” (6.4 cm) from rear wall. 2 Models DR30GIS and DR30GIS include self-rimming trim piece that attaches to back of range and covers the edge of the countertop overhang in back. 3 To create a “built-in look” on the front of the cabinet, this dimension may be changed to 29 1/4” (74.3 cm). This configuration is only for models DR30GIS and DR30GIS with side panels behind door removed.

All specifications subject to change without notice. Phone: (800) 793-0093 www.dacor.com

Show 5 more labels / short text on this page
below countertop · Countertop front · below countertop · Countertop overhang · Countertop overhang
Page 4 of the Dacor DR30GFS user manual — Raised Vent (Self-Rimming) Installation Cutout Options (Models DR30GIS and DR30GIFS Only)
Page 4 · click to enlarge
Page 4

Raised Vent (Self-Rimming) Installation Cutout Options (Models DR30GIS and DR30GIFS Only)

Dacor DR30GFS — Raised Vent (Self-Rimming) Installation Cutout Options (Models DR30GIS and DR30GIFS Only) diagram (page 4)
Fig. 8 · Raised Vent (Self-Rimming) Installation Cutout Optio…

3/8” min. (1.0 cm) flat countertop overhang required behind cutout

For all installations with a raised vent: Countertop height: 34 3/4” (88.3 cm) min. 36 7/8” (93.7 cm) max. Countertop thickness: 1 5/8” (4.1 cm) max.

10” min. (25.4 cm) to any combustibles above counter both sides

Rear wall or countertop edge

3/8” (9.5 mm) min. countertop overhang

Dacor DR30GFS — Raised Vent (Self-Rimming) Installation Cutout Options (Models DR30GIS and DR30GIFS Only) diagram (page 4)
Fig. 9 · Raised Vent (Self-Rimming) Installation Cutout Optio…

27 1/2” (69.9 cm) Cabinet face

3/8” min. (1.0 cm) space behind raised vent chassis to clear stiffener

1 5/8” (4.1 cm) max.

24” - 24 1/4” Cabinet Depth Partial Side Panels Installed (Top View)2

face must be flush with back of control panel.

Side View - DR30GI[F]S Range and

10” min. (25.4 cm) to any combustibles above counter both sides

Rear wall or countertop edge

10” min. (25.4 cm) to any combustibles above counter both sides

3/8” (9.5 mm) min. countertop overhang

Dacor DR30GFS — Raised Vent (Self-Rimming) Installation Cutout Options (Models DR30GIS and DR30GIFS Only) diagram (page 4)
Fig. 10 · Raised Vent (Self-Rimming) Installation Cutout Optio…

3/8” (9.5 mm) min. countertop overhang 3” (7.6 cm)

Rear wall or countertop edge

Dacor DR30GFS — Raised Vent (Self-Rimming) Installation Cutout Options (Models DR30GIS and DR30GIFS Only) diagram (page 4)
Fig. 11 · Raised Vent (Self-Rimming) Installation Cutout Optio…
25 3/4” (65.4 cm) max. 27 1/2” (69.9 cm) raised vent opening 120 7/8 (53.0 c to 24 1/8 (61.3 c 29 1/4” (74.3 cm) countertop opening 30” (76.2 cm) cabinet opening below countertop Notch countertop overhang to width of

1 5/8” (4.1 cm) max.

24 1/4” - 27 1/2” Cabinet Depth Partial Side Panels Installed (Top View)

Custom Cabinet 27 1/2” or Deeper, Partial Side Panels Removed (Top View)

1 To create a “built-in look” on the front of the cabinet, this dimension may be changed to 29 1/4” (74.3 cm). Width notches remains 30”. 2 For 24 to 24 1/4 inch deep cabinets, the side panels and control panel will protrude from the cabinet face a total of 5 5/8 inches.

All specifications subject to change without notice. Phone: (800) 793-0093 www.dacor.com

Show 6 more labels / short text on this page
Countertop overhang · ERV3015 Raised Vent · Countertop · Countertop overhang · below countertop · front
Page 5 of the Dacor DR30GFS user manual — Electrical Specifications/Dimensions, All Models
Page 5 · click to enlarge
Page 5

Self-Rimming Installation, Standard Cutout Requirements (Models DR30GIS and DR30GIFS Only)

10” min. (25.4 cm) to any combustibles above counter both sides

Non-combustible rear wall required

Dacor DR30GFS — Self-Rimming Installation, Standard Cutout Requirements (Models DR30GIS and DR30GIFS Only) diagram (page 5)
Fig. 12 · Self-Rimming Installation, Standard Cutout Requireme…

standard width CUTOUT FOR model dr30dI[F]S

self-rimming TRIM KIT atkdr30Gw required

Electrical Specifications/Dimensions, All Models

Dacor DR30GFS — Electrical Specifications/Dimensions, All Models diagram (page 5)
Fig. 13 · Electrical Specifications/Dimensions, All Models
Dacor DR30GFS — Electrical Specifications/Dimensions, All Models diagram (page 5)
Fig. 14 · Electrical Specifications/Dimensions, All Models

back of range utility clearance behind range

ELECTRICAL REQUIREMENTS Electrical Circuit RequiredTotal Connected Load 120 Vac, 60 Hz, 15 Amps., dedicated, grounded4.0 Amps. @ 120 Vac, 60 Hz
GAS SUPPLY PRESSURE REQUIREMENTS Gas TypeManifold Pressure* (WC)Min. Gas Supply Pressure (WC)Max. Input Pressure Natural5”6”1/2 psi LP10”11”1/2 psi
Dacor DR30GFS — Electrical Specifications/Dimensions, All Models diagram (page 5)
Fig. 15 · Electrical Specifications/Dimensions, All Models

The gas inlet on the regulator accommodates a 1/2” NPT gas line connection. The range can also accommodate a 3/4” NPT gas line connection by removing the 1/2” to 3/4” adapter on the regulator inlet.

All specifications subject to change without notice. Phone: (800) 793-0093 www.dacor.com

Countertop front

Ask about the Dacor DR30GFS

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Dacor DR30GFS

Be the first to ask — other owners or our team will answer.

Original document

Dacor DR30GFS manual PDF

5 pages·695 KB·Ventilation Hood·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…