Distinctive ™ Rangep.1Table of Contentsp.2IMPORTANT:p.2Customer Service Informationp.2Model Identificationp.2DR30DIH-C/NG/Hp.2SIZE (inches)p.2TRIM STYLEp.2HANDLE TYPEp.2COUNTRY CODEp.2GAS TYPEp.2ALTITUDEp.2Product Model/Serial Label and Rating Label Locationsp.2Important Safety Instructionsp.3About Safety Instructionsp.3DANGERp.3cautionp.3CALIFORNIA PROPOSITION 65 WARNINGp.3READ AND SAVE THESE INSTRUCTIONSp.3General Safety Precautionsp.4warning warningp.4NEMA 10-50P Plug NEMA 14-50P Plugp.5NEMA 14-50R Receptacle NEMA 10-50R Receptaclep.5Gas Supply Requirementsp.6Electrical and Gas Supply Connectionsp.6Gas and Electrical Dimensionsp.6Product tolerances: ±1/16” (±1.6 mm), unless otherwise stated Product Dimensionsp.7Side View - DR30D[H] (Freestanding Model)p.7NOTES:p.7Side View - DR30DI[H] (Self-Rimming Model)p.7Cabinet Layoutp.8Gas and Electrical Servicep.8The installation must allow for the following:p.8Required Cabinet Dimensionsp.8Self-Rimming Installation Without Raised Ventp.9Model DR30DI[H] Countertop Self-Rimmed Only,p.9Self-Rimmed, 3 1/4 Inch Side Panels Removedp.9Top View Top Viewp.9Self-Rimming Installation With Raised Ventp.10Model DR30DI/ERV3015 Countertop Self-Rimmed Only,p.103 1/4 Inch Side Panels Not Removedp.10J Kp.10Top Viewp.10Side Viewp.10Model DR30DI[H]/ERV3015 Countertopp.11and Cabinet Front Self-Rimmed, 3 1/4 Inch Side Panels Not Removedp.11and Cabinet Front Self-Rimmed, 3 1/4 Inch Side Panels Removedp.11Side View Side Viewp.11Preparing for Installationp.12Install the Anti-Tip Bracket and Footp.12There are two ways to mount the anti-tip bracket:p.12Installing the Anti-Tip Bracket on the Floorp.12Unpacking the Rangep.12Parts Listp.12Attaching the bracket to a concrete floor:p.13Attaching the bracket to a wood floor:p.13Top View - Location of Floor Mounted Anti-Tip Bracketp.13Preparing for Installation (cont.)p.14Installing the Anti-Tip Bracket on the Wallp.14Top View - Location of Wall Mounted Anti-Tip Bracketp.14Removing the Oven Doorp.15Optional Backguard/Island Trim Installation (Freestanding Model, DR30D[H] Only)p.15Side Panel Removal on Model DR30DI[H]p.15Door Gripping Pointsp.15Electrical Connectionp.16Appliance Cord Connections - Where Local Code Permitsp.16Types of Electrical Connectionsp.163-wire Appliance Cord Connection - Where Local Code Permitsp.1714-50P Plugp.17Electrical Connection (cont.)p.18Connecting Conduit to the Rangep.184-Wire Conduit Connectionp.18(preferred)p.183-Wire Conduit Connection - Where Local Code Permitsp.18Connecting the Conduit to the House Electrical Junction Boxp.19Insulated Pipe Jumperp.193-Wire Conduit-Junction Box Connection with External Groundp.19Gas Connectionp.20Final Installationp.20Anti-Tip Foot Locationp.20
Page 1 of the Dacor DR30DI user manual — Distinctive ™ Range
Page 1 · click to enlarge
Page 1
Dacor DR30DI — Distinctive ™ Range diagram (page 1)
Fig. 1 · Distinctive ™ Range

Distinctive ™ Range

ModelsDR30D, DR30DH, DR30DI, DR30DIH, DR30D-C, DR30DH-C, DR30DI-C and DR30DIH-C

THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITIONs OF UL858/CSA C22.2 No. 61/ANSI Z21.1 STANDARDs FOR HOUSEHOLD COOKING APPLIANCES.

Part No. 106769 Rev. F

Page 2 of the Dacor DR30DI user manual — Table of Contents
Page 2 · Contents
Contents

Contents

Distinctive ™ Rangep.1Table of Contentsp.2IMPORTANT:p.2Customer Service Informationp.2Model Identificationp.2DR30DIH-C/NG/Hp.2SIZE (inches)p.2TRIM STYLEp.2HANDLE TYPEp.2COUNTRY CODEp.2GAS TYPEp.2ALTITUDEp.2Product Model/Serial Label and Rating Label Locationsp.2Important Safety Instructionsp.3About Safety Instructionsp.3DANGERp.3cautionp.3CALIFORNIA PROPOSITION 65 WARNINGp.3READ AND SAVE THESE INSTRUCTIONSp.3General Safety Precautionsp.4warning warningp.4NEMA 10-50P Plug NEMA 14-50P Plugp.5NEMA 14-50R Receptacle NEMA 10-50R Receptaclep.5Gas Supply Requirementsp.6Electrical and Gas Supply Connectionsp.6Gas and Electrical Dimensionsp.6Product tolerances: ±1/16” (±1.6 mm), unless otherwise stated Product Dimensionsp.7Side View - DR30D[H] (Freestanding Model)p.7NOTES:p.7Side View - DR30DI[H] (Self-Rimming Model)p.7Cabinet Layoutp.8Gas and Electrical Servicep.8The installation must allow for the following:p.8Required Cabinet Dimensionsp.8Self-Rimming Installation Without Raised Ventp.9Model DR30DI[H] Countertop Self-Rimmed Only,p.9Self-Rimmed, 3 1/4 Inch Side Panels Removedp.9Top View Top Viewp.9Self-Rimming Installation With Raised Ventp.10Model DR30DI/ERV3015 Countertop Self-Rimmed Only,p.103 1/4 Inch Side Panels Not Removedp.10J Kp.10Top Viewp.10Side Viewp.10Model DR30DI[H]/ERV3015 Countertopp.11and Cabinet Front Self-Rimmed, 3 1/4 Inch Side Panels Not Removedp.11and Cabinet Front Self-Rimmed, 3 1/4 Inch Side Panels Removedp.11Side View Side Viewp.11Preparing for Installationp.12Install the Anti-Tip Bracket and Footp.12There are two ways to mount the anti-tip bracket:p.12Installing the Anti-Tip Bracket on the Floorp.12Unpacking the Rangep.12Parts Listp.12Attaching the bracket to a concrete floor:p.13Attaching the bracket to a wood floor:p.13Top View - Location of Floor Mounted Anti-Tip Bracketp.13Preparing for Installation (cont.)p.14Installing the Anti-Tip Bracket on the Wallp.14Top View - Location of Wall Mounted Anti-Tip Bracketp.14Removing the Oven Doorp.15Optional Backguard/Island Trim Installation (Freestanding Model, DR30D[H] Only)p.15Side Panel Removal on Model DR30DI[H]p.15Door Gripping Pointsp.15Electrical Connectionp.16Appliance Cord Connections - Where Local Code Permitsp.16Types of Electrical Connectionsp.163-wire Appliance Cord Connection - Where Local Code Permitsp.1714-50P Plugp.17Electrical Connection (cont.)p.18Connecting Conduit to the Rangep.184-Wire Conduit Connectionp.18(preferred)p.183-Wire Conduit Connection - Where Local Code Permitsp.18Connecting the Conduit to the House Electrical Junction Boxp.19Insulated Pipe Jumperp.193-Wire Conduit-Junction Box Connection with External Groundp.19Gas Connectionp.20Final Installationp.20Anti-Tip Foot Locationp.20
Page 3 of the Dacor DR30DI user manual — READ AND SAVE THESE INSTRUCTIONS
Page 3 · click to enlarge
Page 3

Important Safety Instructions

About Safety Instructions

The Important Safety Instructions and warnings in this manual are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance.

  • A child or adult can tip the range and be killed.
  • Attach the anti-tip bracket to the floor or wall as directed in these installation instructions.

Always contact the Dacor Customer Service Team about problems and conditions that you do not understand. Safety Symbols in this Manual

  • Engage the floor or wall mounted anti-tip bracket by sliding the anti-tip foot on the range into it according to these installation instructions. Using a flashlight, be sure that the anti-tip bracket engages the range’s anti-tip foot as shown below.

DANGER

  • After moving the range, be sure to re-engage the anti-tip foot into the anti-tip bracket as shown below.

Immediate hazards that WILL result in severe personal injury or death.

  • See the anti-tip bracket installation instructions in this guide for further details.
  • Failure to follow these instructions can result in death or serious burns to children or adults.

Hazards or unsafe practices that COULD result in severe personal injury or death.

caution

Hazards or unsafe practices that COULD result in minor personal injury or property damage.

DANGER

  • Do not use or light any appliance.
  • Do not touch any electrical switch or use any electrical devices, including the telephone, in your building.
  • From a neighbor’s phone, immediately call the gas supplier. Follow the gas supplier’s instructions.
  • If you cannot contact the gas supplier, call the fire department.

CALIFORNIA PROPOSITION 65 WARNING

The burning of gas cooking fuel generates some by-products that are on the list of substances which are known by the State of California to cause cancer or reproductive harm. California law requires businesses to warn customers of potential exposure to such substances. To minimize exposure to these substances, always operate this unit according to the use and care manual, ensuring you provide good ventilation when cooking with gas.

READ AND SAVE THESE INSTRUCTIONS

Anti-tip bracket · Anti-tip foot

Page 4 of the Dacor DR30DI user manual — warning warning
Page 4 · click to enlarge
Page 4

Important Safety Instructions

General Safety Precautions

To reduce the risk of fire, explosion, electric shock, serious injury or death when installing or using this appliance, follow basic safety precautions, including the following:

warning warning

  • Read the accompanying use and care manual completely before operating this appliance.
  • If the range is near a window, do not use long curtains as window treatment. The curtains could blow over the cooktop and create a fire hazard.
  • Keep packaging materials away from children. Plastic sheets and bags can cause suffocation.
  • Keep flammable items, such as paper, cardboard, plastic and cloth away from the burners and other hot surfaces. Do not place such items in the oven. Do not allow pot holders to touch hot surfaces or gas burners.
  • If you receive a damaged product, immediately contact your dealer or builder. Do not install or use a damaged appliance.
  • Do not wear loose or hanging apparel while using the range. Do not allow clothing to come into contact with the interior of the oven or the cooktop and surrounding areas during and immediately after use.
  • This range must be properly installed by a qualified installer according to these installation instructions prior to use. The installer must show the customer the location of the gas shut off valve and the circuit breaker panel or fuse box so that they know where and how to turn off the gas supply and electric power to the range.
  • To avoid a fire hazard, do not hang flammable or heat sensitive objects over the range.
  • To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above surface units should be avoided.
  • Do not use the oven for storage.
  • Do not touch the burner assembly, grates or surrounding surfaces (including the backguard) or the interior surfaces of the oven during use. After use, make sure these surfaces have had sufficient time to cool before touching them.
  • Do not install, repair or replace any part of the range unless specifically recommended in the literature accompanying it. A qualified service technician should perform all other service.
  • Make sure that all the cooktop parts are dry before lighting a burner.
  • Do not connect this range to the gas supply without the supplied gas pressure regulator installed.
  • Turn the knobs to the OFF position prior to removing them from the valve stems.
  • Before performing any type of service or installation, make sure that the gas supply and power to the range are off.
  • Do not operate the cooktop without the knobs and trim rings in place.
  • NEVER block or cover any slots, holes or passages anywhere inside the oven or on the outside of the range or cover an oven rack with materials such as aluminum foil. Doing so blocks airflow through the oven and cooktop and may cause carbon monoxide poisoning or fire. See the Getting to Know Your Range section of the use and care manual for the location of the various air holes (slots).
  • For your safety, do not use the oven to cook without the convection filter installed. When the filter is not installed, the spinning fan blades at the back of the oven are exposed.
  • Non-stick coatings, when heated, can be harmful to birds. Remove birds to a separate, well-ventilated room during cooking.
  • Only use this range for cooking tasks expected of a home appliance as outlined in the literature accompanying it. This range is not intended for commercial use.
  • To prevent damage, remove the meat probe from the oven when it is not being used.
  • DO NOT TOUCH THE SURFACES OF THE OVEN OR COOKTOP DURING OR IMMEDIATELY AFTER USE.
  • Do not line the oven with aluminum foil or other materials. These items can melt or burn up during self-cleaning and cause permanent damage to the oven.
  • Do not climb on any part of the appliance.
  • Never leave this appliance unattended when in use.
  • Do not leave children or pets alone or unattended in the area around the range. Do not allow children to play with the controls, pull on the handle, or touch other parts of the range.
  • Do not leave objects, such as aluminum foil, the meat probe, cookie sheets, etc. on the bottom of the oven. Damage to the oven or the objects themselves may result.
  • Do not cover the broil element on the ceiling of the oven with cookie sheets, aluminum foil, pots, pans, etc. Covering them could cause the heating elements to over-heat, damaging the oven.
  • Do not store items of interest to children on top of or above the range. Children could be burned or injured while climbing on the appliance.
  • Do not attempt to use this appliance in the event of a power failure.
  • Do not expose the knobs or trim rings to direct flame, hot utensils or other sources of heat.
  • Do not tamper with the controls. Do not adjust or alter any part of the range unless specifically instructed to do so in these instructions.
  • Always ensure that the light fixture lens cover is in place when using the oven. The lens cover protects the light bulb from breakage caused by high oven temperatures or mechanical shock.
  • Clean the cooktop thoroughly before operating it for the first time.
Page 5 of the Dacor DR30DI user manual — NEMA 14-50R Receptacle NEMA 10-50R Receptacle
Page 5 · click to enlarge
Page 5
Dacor DR30DI — NEMA 10-50P Plug NEMA 14-50P Plug diagram (page 5)
Fig. 2 · NEMA 10-50P Plug NEMA 14-50P Plug
  • Model numbers that end in -C are freestanding ranges that come with a factory installed 4-wire appliance cord and NEMA 14-50P plug. This wiring configuration is required for freestanding ranges installed in Canada, although they may be used elsewhere, if local codes permit. The plug is designed to plug directly into a NEMA 14-50R electrical receptacle installed by a licensed electrician according to the specifications below. Do not modify the factory wiring on models with -C at the end of the model number.

It is the owner’s responsibility to ensure that a licensed electrician performs the installation of the electrical supply for this appliance. The electrical installation, including minimum supply wire size, must comply with the National Electric Code ANSI/NFPA 70 (latest revision) and local codes and ordinances. A copy of this standard may be obtained from:

  • It is the owner’s responsibility to ensure that the required 4-wire electrical outlet compatible with the power cord is installed by a licensed electrician as specified below prior to range installation. The electrical outlet installation, including minimum supply wire size and grounding, must be in accordance with all governing codes and ordinances.

National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101

  • The correct voltage, frequency and amperage must be supplied to the appliance from a separate, grounded, circuit that is protected by a properly sized circuit breaker or time delay fuse. If a fuse is utilized, fuse both sides of the line (L1 and L2). Refer to the ratings on the range rating label.
  • The correct voltage, frequency and amperage must be supplied to the appliance from a separate, grounded, circuit that is protected by a properly sized circuit breaker or time delay fuse. If a time-delay fuse is utilized, fuse both sides of the line (L1 and L2).
Electrical Specifications Circuit RequiredTotal Connected Load 240 Vac, 60 Hz., 4-wire*, 30 Amp.5.7 kW (23.8 Amp.)
Electrical Specifications Circuit RequiredTotal Connected Load 240 Vac, 60 Hz., 4-wire*, 30 Amp.5.7 kW (23.8 Amp.)

* Two 120 Vac hot (L1 and L2), one neutral (N1) and one ground.

* The ratings above are for reference only - refer to the product data label for exact specifications.

The above electrical specifications are for reference only. See the range data label for exact specifications. See inside cover for location.

The ratings above are for reference only - refer to the range rating label (see inside cover).

  • The wiring needs to be long enough to allow the range to be pulled out for service, while remaining connected.
  • The wiring connected to the range must:

◊ Meet NEMA standards and have a minimum rating of 250 Volts @ 30 Amp.

◊ Include a strain relief.

◊ Be terminated by tinned leads, closed loop terminals or open ended spade lugs with upturned ends.

◊ Connect to a junction box or receptacle installed by a licensed electrician.

NEMA 10-50P Plug NEMA 14-50P Plug

The appliance may be connected one of the following ways:

  • Using conduit:

◊ A 4-wire conduit connected to a 4-wire junction box, or

◊ A 3-wire conduit (where local code permits) connected to a 3-wire junction box.

Suggested conduit wiring color code: black, white, red and green.

  • Using an appliance cord:

◊ A 4-wire appliance cord equipped with a NEMA 14-50P plug connected to a NEMA 14-50R receptacle, or

NEMA 14-50R Receptacle NEMA 10-50R Receptacle

◊ A 3-wire appliance cord (where local code permits) equipped with a NEMA 10-50P plug connected to a NEMA 10-50R receptacle.

Appliance cord plug must be UL listed type SRD or SRDT.

Page 6 of the Dacor DR30DI user manual — Gas and Electrical Dimensions
Page 6 · click to enlarge
Page 6

Gas Supply Requirements

  • Check your local building codes for the proper method of installation. In the absence of local codes, this appliance should be installed in accordance with the National Fuel Gas Code ANSI Z223.1.
Dacor DR30DI — Gas Supply Requirements diagram (page 6)
Fig. 3 · Gas Supply Requirements
Gas Supply Specifications Gas TypeManifold Pressure* (WC)Min. Gas Supply Pressure (WC)Max. Input Pressure Natural561/2 psi LP10111/2 psi
  • Be certain that the appliance being installed is correct for the gas service provided (natural gas or LP gas). Also, if operating the range at an altitude above 4000 ft. (1219 m) make sure it is equipped for high altitude operation. Refer to the product data label and the table on the inside cover to determine the correct model.

The ratings above are for reference only - refer to the product data label (see inside cover for location).

  • See the table for gas supply pressure requirements.
  • The regulator inlet accommodates a 3/4” gas line. The range ships with a 1/2” to 3/4” adapter connected to the regulator.

Electrical and Gas Supply Connections

Dacor DR30DI — Electrical and Gas Supply Connections diagram (page 6)
Fig. 4 · Electrical and Gas Supply Connections
ABCD 4 3/4” (12.1 cm)22 1/8” (56.2 cm)8 3/4” (22.2 cm)13 3/4” (34.9 cm)

* When using an appliance cord that is not factory installed, the hole size must be increased to 1 1/8” (2.9 cm) by removing the conduit bracket inside the range electrical access box (see page 14).

7/8” (2.2 cm) dia. electrical connection hole in bottom*

Gas and Electrical Dimensions

Page 7 of the Dacor DR30DI user manual — Side View - DR30DI[H] (Self-Rimming Model)
Page 7 · click to enlarge
Page 7

Product tolerances: ±1/16” (±1.6 mm), unless otherwise stated Product Dimensions

Dacor DR30DI — Product tolerances: ±1/16” (±1.6 mm), unless otherwise stated Product Dimensions diagram (page 7)
Fig. 5 · Product tolerances: ±1/16” (±1.6 mm), unless otherwi…
28 7/8” (73.3 cm) 28 1/2” (72.4 cm) 26 1/2” (67.3 cm) 24 3/8” (61.9 cm)

9” (22.9 cm) Backguard** 6” (15.2 cm) Backguard** 3” (7.7 cm) Backguard*

1 1/8” (2.9 cm) to cooking surface (top of grates) from top of trim

Optional Backguard and Island Trim Part Number Island trim kit (no backguard)ADTK30D 6 inch trim kitADB3006 9 inch trim kitADB3009

Side View - DR30D[H] (Freestanding Model)

Dacor DR30DI — Side View - DR30D[H] (Freestanding Model) diagram (page 7)
Fig. 6 · Side View - DR30D[H] (Freestanding Model)

Front of open door

28 11/16” (72.9 cm) 28 5/16” (71.9 cm) 26 5/16” (66.8 cm) 24 3/16” (61.4 cm)

Control panel Front of knobs

Rear of control panel/oven door

5/16” (8 mm) Trim thickness

1 7/16” (3.7 cm) to cooking surface (top of grates) from bottom of trim

NOTES:

  • When installing model DR30DI[H] with a raised vent, install only Dacor model ERV3015.
  • The backguards shown above for model DR30D[H] are NOT compatible with model DR30DI[H].
  • Model DR30DI[H] can be installed in a freestanding configuration provided the trim around the cooktop is level with the surrounding countertop.

Side View - DR30DI[H] (Self-Rimming Model)

Rear trim overhang

Page 8 of the Dacor DR30DI user manual — Required Cabinet Dimensions
Page 8 · click to enlarge
Page 8

Cabinet Layout

Gas and Electrical Service

  • The shaded area shown below denotes the location of the gas inlet and the electrical junction box/receptacle. This is the recommended location. For replacement purposes, the location of the existing utilities may be utilized provided they do not interfere with the sides or rear of the range. Check local building codes for permissible utility connection locations.
Dacor DR30DI — Gas and Electrical Service diagram (page 8)
Fig. 7 · Gas and Electrical Service

All maximum and minimum cabinet and countertop dimensions and clearances stated in these instructions must be maintained for safe operation.

  • Carefully check the location where the range is to be installed. For best performance, the range should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets.
  • An external manual shut-off valve must be installed between the gas inlet and the range for the purpose of turning on or shutting off gas to the appliance.
  • To reduce the risk of personal injury and to reduce accumulated smoke in the room, Dacor strongly recommends installing a range hood or raised vent (model DR30DI[H] only). A range hood should project horizontally a minimum of five (5) inches beyond the face of the cabinets.

The installation must allow for the following:

  • Access to the gas shut-off valve when the unit is installed.
  • Access to the remote circuit breaker panel or fuse box when the range is in place.
  • The gas supply piping, gas shut-off valve and the electrical junction box or receptacle must be located so they do not interfere with the range when it is installed.
  • Any openings in the wall behind the appliance or in the floor underneath it must be sealed.
  • Carefully note the requirements stated below for clearances to walls and cabinets.
  • The junction box and gas shut off valve must be located so that the range can be pulled out for service while the appliance remains connected.
Cutout tolerances+1/16” (+1.6 mm), -0

E

EF*** 36” (91.4 cm)* 30” (76.2 cm)**30 1/16” (76.4 cm) * R *** Seeecommended ** Minimum following pages for self-rimming installations

13” (33.0 cm) max.5

30” (76.2 cm) min.2

10” (25.4 cm) min. to combustible side walls above the range (both sides)

18” (45.7 cm) min.2, 5

F

1 Minimum distance to a combustible rear wall for model DR30DI[H] is 2.5” (6.4 cm) from top rear trim. Model DR30D[H] may be installed flush to rear wall, but non-combusible surface or 9-inch backguard (PN ADB3009) is recommended.

Suggested location of utilities 4

2 Distance to combustible surfaces measured from cooking surface (top of cooktop grate); if installing an overhead range hood, also check the hood specifications for minimum required clearances.

1 Minimum distance to a combustible rear wall for model DR30DI[H] is 2.5” (6.4 cm) from top rear trim. Model DR30D[H] may be installed flush to rear wall, but non-combusible surface or 9-inch backguard (PN ADB3009) is recommended.

3 Cabinet/countertop depth is at discretion of customer but cabinet face MUST NOT protrude further than rear of cabinet front, see Product Dimensions.

2 Distance to combustible surfaces measured from cooking surface (top of cooktop grate); if installing an overhead range hood, also check the hood specifications for minimum required clearances.

4 Consult local code for exact location requirements.

5 This specification does not apply for cabinets located greater than a horizontal distance of 10” (25.4 cm) from the edge of the range.

3 Cabinet/countertop depth is at discretion of customer but cabinet face MUST NOT protrude further than rear of cabinet front, see Product Dimensions.

6 Model DR30D[H]: 37 7/8 (96.2 cm) max. Model DR30DI[H]: 37 7/16 (95.1 cm) max.

4 Consult local code for exact location requirements.

Required Cabinet Dimensions

Back wall 1

Page 9 of the Dacor DR30DI user manual — Top View Top View
Page 9 · click to enlarge
Page 9

Self-Rimming Installation Without Raised Vent

  • When sliding the range into position, it will stop when the rear of the side panels or front panel contacts the notches toward the front of the countertop. The rear of the range trim will overhang the countertop in back.
  • See page 8 for raised vent installations.
Model DR30DI Range WithHJK Countertop SelfRimmed Only21” (53.3 cm)0” (0 cm) to 3 1/4” (8.3 cm)0” (0 cm) to 5 3/8” (13.7 cm) Countertop and Cabinet Front Self-Rimmed 124 1/4” (61.6 cm)NA0” (0 cm) to 2 1/8” (5.4 cm)
Dacor DR30DI — Self-Rimming Installation Without Raised Vent diagram (page 9)
Fig. 8 · Self-Rimming Installation Without Raised Vent
  • Only model DR30DI may be installed in a self-rimming configuration. Self-rimming installations create a “built-in” look where the trim of the range overlaps the surrounding countertop. It is also possible, if the cabinets are the right depth, to self rim the front of the range into the cabinet face, immediately behind the control panel and door trim. When the front of the range is self-rimmed, the 3 1/4” side panels are removed.

1 Side panels removed

Countertop height for all self-rimming installations: 35 7/16” (90.0 cm) minimum, 37 7/16” (95.1 cm) maximum

Model DR30DI[H] Countertop Self-Rimmed Only,

3 1/4 Inch Side Panels Not Removed Model DR30DI[H] Countertop and Cabinet Front

Self-Rimmed, 3 1/4 Inch Side Panels Removed

Dacor DR30DI — Self-Rimmed, 3 1/4 Inch Side Panels Removed diagram (page 9)
Fig. 9 · Self-Rimmed, 3 1/4 Inch Side Panels Removed
Dacor DR30DI — Self-Rimmed, 3 1/4 Inch Side Panels Removed diagram (page 9)
Fig. 10 · Self-Rimmed, 3 1/4 Inch Side Panels Removed
29 1/4” (74.3 cm) countertop opening 30” (76.2 cm) cabinet opening below countertop

Top View Top View

below countertop To cabinet face

below countertop Cabinet face

* When increasing overhang, increase dimension H by same amount.

* When increasing overhang, increase dimension H by same amount.

** Any vertical surfaces behind the range must be non-combustible unless countertop overhang exceeds 2 3/4” (7.0 cm).

** Any vertical surfaces behind the range must be non-combustible unless countertop overhang exceeds 2 3/4” (7.0 cm).

See Top View for required distance

Dacor DR30DI — Top View Top View diagram (page 9)
Fig. 11 · Top View Top View

See Top View for required distance to vertical surfaces

Back of control panel and trim behind door rest against cabinet face DR30DI[H] range

front · front

Page 10 of the Dacor DR30DI user manual — Side View
Page 10 · click to enlarge
Page 10

Self-Rimming Installation With Raised Vent

Cutout tolerances+1/16” (+1.6 mm), -0

Model DR30DI/ERV3015 Countertop Self-Rimmed Only,

3 1/4 Inch Side Panels Not Removed

  • Only model DR30DI may be installed with a raised vent. Use only Dacor raised vent model ERV3015.
  • A self-rimming countertop configuration is required for raised vent installation. On installations with a raised vent, when sliding the range into position, it will stop when the rear of the control panel or side panels contact the notches toward the front of the countertop.

3/8” min. (1.0 cm) countertop

10” min. (25.4 cm) both sides

  • The self-rimming installation of the DR30DI range and ERV3015 raised vent create a “built-in” look where the range trim overlaps the countertop on both sides and the raised vent overlaps the countertop in back. It is also possible, if the cabinets are deep enough, to self rim the front of the range into the cabinet face immediately behind the control panel and door trim or behind the side panels (see side views on this and the facing page). The rear range trim will partially cover the front of the raised vent chassis in back.

cabinet opening below countertop

H

Combustible side wall above range

Model DR30DI Range and ERV3015 Raised Vent WithHJK Countertop selfrimmed only20 5/8” (52.4 cm)0” (0 cm) to 3 1/4” (8.3 cm)0” (0 cm) to 5 3/8” (13.7 cm) Countertop and Cabinet Front Self-Rimmed,20 5/8” * (52.4 cm)NA0” (0 cm) to 5 3/8” (13.7 cm) Countertop and Cabinet Front Self-Rimmed (side panels removed)23 7/8” * (60.6 cm)NA0” (0 cm) to 2 1/8” (5.4 cm)

J K

Notch countertop overhang to width of

below countertop To cabinet face To countertop

Top View

3/8” min. (1.0 cm) flat countertop overhang required behind cutout

* Cabinet face below countertop must be flush with back of notch in countertop.

Countertop height for all self-rimming installations: 35 7/16” (90.0 cm) minimum, 37 7/16” (95.1 cm) maximum

Back of control panel DR30DI[H] range

H

3 1/4 inch side panel

3/8” min. (1.0 cm) space required behind ERV3015 chassis to clear stiffener

Side View

Show 11 more labels / short text on this page
Non-combustible · rear wall recommended · overhang · raised vent opening · countertop opening · cabinets · front · Range trim resting · on countertop · Cabinet face Countertop · ERV3015 raised vent
Page 11 of the Dacor DR30DI user manual — Side View Side View
Page 11 · click to enlarge
Page 11

Model DR30DI[H]/ERV3015 Countertop

Model DR30DI[H]/ERV3015 Countertop

and Cabinet Front Self-Rimmed, 3 1/4 Inch Side Panels Not Removed

and Cabinet Front Self-Rimmed, 3 1/4 Inch Side Panels Removed

Dacor DR30DI — Model DR30DI[H]/ERV3015 Countertop diagram (page 11)
Fig. 12 · Model DR30DI[H]/ERV3015 Countertop
Dacor DR30DI — Model DR30DI[H]/ERV3015 Countertop diagram (page 11)
Fig. 13 · Model DR30DI[H]/ERV3015 Countertop

below countertop Cabinet face To countertop

below countertop Cabinet face To countertop

Top View Top View

Dacor DR30DI — Top View Top View diagram (page 11)
Fig. 14 · Top View Top View
Dacor DR30DI — Top View Top View diagram (page 11)
Fig. 15 · Top View Top View

3/8” min. (1.0 cm) flat countertop overhang required behind cutout

3/8” min. (1.0 cm) flat countertop overhang required behind cutout

Back of control panel and trim behind door rest against cabinet face

3/8” min. (1.0 cm) space required behind ERV3015 chassis to clear stiffener

3/8” min. (1.0 cm) space required behind ERV3015 chassis to clear stiffener

Side View Side View

front · front

Page 12 of the Dacor DR30DI user manual — Parts List
Page 12 · click to enlarge
Page 12

Preparing for Installation

Install the Anti-Tip Bracket and Foot

Dacor DR30DI — Preparing for Installation diagram (page 12)
Fig. 16 · Preparing for Installation

Locate the anti-tip bracket included in the parts box.

There are two ways to mount the anti-tip bracket:

  • If the gas or electric service provided does not meet the product specifications, do not proceed with the installation. Call the dealer, the gas supplier or a licensed electrician.
  • Floor mounting (preferred method)
  • Wall mounting (alternate method). Use this method if floor mounting is not suitable. If the front panel of range is further than 27 1/2” (69.9 cm) from the back wall or if the flooring is too thick (see Installing the Anti-Tip Bracket on the Wall ), the wall mounting method may not be used and the floor mounting method must be suitable.
  • Before installing the range, you must locate and secure the anti-tip bracket as instructed.
  • Be sure that the unit is not connected to gas or power before proceeding with the following sections.

Installing the Anti-Tip Bracket on the Floor

Dacor DR30DI — Installing the Anti-Tip Bracket on the Floor diagram (page 12)
Fig. 17 · Installing the Anti-Tip Bracket on the Floor

Unpacking the Range

Unpack the range and verify that all required parts have been provided. If any item is missing or damaged, please contact your dealer immediately. Do not install a damaged or incomplete appliance. The customer must report cosmetic issues within 30 days of installation.

To perform its intended function, the anti-tip bracket must be attached as instructed to the concrete slab or wood sub-floor below any floor coverings (including cement board) on top. Do not attach the anti-tip bracket directly to floor coverings such as ceramic/asphalt tile or linoleum.

Parts List

Dacor DR30DI — Parts List diagram (page 12)
Fig. 18 · Parts List
  • 2 grates
  • 1 small standard burner cap
  • 1 small standard burner ring
  • 2 large standard burner caps
  • 2 large standard burner rings
  • 1 inner SimmerSear™ burner cap
  • 1 outer SimmerSear burner cap
  • 1 SimmerSear burner ring
  • 2 standard oven racks
  • 1 GlideRack oven rack
  • Anti-tip bracket w/screws and anchors
  • Meat probe
  • Dacor Stainless Steel Cleaner
  • Literature kit

Concrete anchors shown, do

not use for wood sub-floor

Four (4) plastic anchors are provided along with three sizes (4 each) of #8 or #12 Phillips head screws for attaching the anti- tip bracket to the floor. Use both the anchors and four (4) of the screws when attaching the bracket to a concrete sub-floor. Do not use the anchors when attaching to a wood sub-floor.

Sub-floor

Page 13 of the Dacor DR30DI user manual — Top View - Location of Floor Mounted Anti-Tip Bracket
Page 13 · click to enlarge
Page 13
1. Determine the location of the range center line and front panel for the range’s final position based on the Product Dimensions on page 5 and the actual cabinet/cutout dimensions used for the installation.

Attaching the bracket to a concrete floor:

  • Drill four (4) 3/8” diameter countersink holes through any existing floor covering down to the concrete slab below.
  • Drill the 4 holes for the anchors 1 1/4” (3.2 cm) deep into the concrete slab using a 3/16” masonry bit. This hole length is longer than the anchor, but is required for proper installation. Clear the holes of dust and any other material. Tap each anchor into the hole until the anchor top is flush with the top of the concrete slab. Position the anti-tip bracket holes over the anchor holes. Insert the screws through the 4 holes in the base of the bracket and thread them into the anchors. Be sure the screw threads fully engage the anchor body. Tighten the screws into place.
2. Determine the required position of the anti-tip bracket, based on the diagram below. Mark the four (4) mounting hole locations on the floor with a pencil.
Dacor DR30DI — Attaching the bracket to a concrete floor: diagram (page 13)
Fig. 19 · Attaching the bracket to a concrete floor:

Attaching the bracket to a wood floor:

  • If there is ceramic, asphalt or other hard floor covering over the wood below, drill (4) countersink holes to allow access to the wood below for drilling pilot holes.
  • Drill four (4) pilot holes into the wood floor using a drill bit (1/16” dia. for #8 screws, 1/8” dia. for #12 screws). Position the anti-tip bracket holes over the holes in the floor. Insert the screws into the wood and tighten into place.

Top View - Location of Floor Mounted Anti-Tip Bracket

3. Determine the screw size required. The minimum full thread depth (portion of screw threaded into wood/slab) for wood is 3/8” (1 cm) and 5/8” (1.6 cm) for concrete. See the table below to select the correct screw size.
Dacor DR30DI — Top View - Location of Floor Mounted Anti-Tip Bracket diagram (page 13)
Fig. 20 · Top View - Location of Floor Mounted Anti-Tip Bracke…

covering up to 1/4” thick #8 x 1 *

Concrete or wood sub-floor, floor covering over 1/4” and up to 1/2” thick #8 x 1 1/4 *

1/2” and up to 1 3/16” thick #12 x 1 3/4 *

* Included with range

** Determine required depth based on information in step 3 and purchase from local hardware store.

Page 14 of the Dacor DR30DI user manual — Top View - Location of Wall Mounted Anti-Tip Bracket
Page 14 · click to enlarge
Page 14

Preparing for Installation (cont.)

2. To install the bracket, place it against the wall in the mounting location. Using a drill with 1/8” diameter drill bit, drill four (4) 1 5/8” deep pilot holes perpendicular to the screw seating surfaces shown below. Attach the bracket to the wall as shown with the four (4) included #12 x 1 3/4 screws.

Installing the Anti-Tip Bracket on the Wall

1. Determine the suitability of wall mounting the anti-tip bracket. To use the wall mount option, the range front panel must not be more than 27 1/2” from the wall and the bracket screws must be able to thread into the base plate inside the wall behind. The notches on the sides of the bracket indicated the minimum required height of the base plate inside the wall and that any floor covering is not too thick for proper screw thread engagement.

This hole lines up with

Dacor DR30DI — Installing the Anti-Tip Bracket on the Wall diagram (page 14)
Fig. 21 · Installing the Anti-Tip Bracket on the Wall
Dacor DR30DI — Installing the Anti-Tip Bracket on the Wall diagram (page 14)
Fig. 22 · Installing the Anti-Tip Bracket on the Wall

26 1/2” (67.3 cm) to 27 1/2” (69.9 cm)

To determine if the base plate is high enough:

◊ Determine the location of the range center line and front panel when the range is in its final position based on the product dimensions on page 5 and the actual cabinet/cutout dimensions used for the installation.

Top View - Location of Wall Mounted Anti-Tip Bracket

◊ Determine and mark the required position of the anti-tip bracket, based on the diagram above. Push the bracket up against the wall in the mounting location.

◊ Using a pencil, make a dot next to the notches on both sides of the bracket. Determine if the base plate is as high at the notches by drilling test holes into the wall at both dots with a 1/16” drill bit. Drill just deep enough to see if the bit contacts the base plate. If the bit contacts the base plate the location will support wall installation of the anti-tip bracket. If you do not contact the base plate, the wall mounting method may not be used and the floor mounting method must be suitable, or the wall must be modified so that the base plate is above the notches.

Base plate · Bracket center line

Page 15 of the Dacor DR30DI user manual — Door Gripping Points
Page 15 · click to enlarge
Page 15

Removing the Oven Door

Optional Backguard/Island Trim Installation (Freestanding Model, DR30D[H] Only)

To make the range easier to move, remove the door to reduce weight.

When used, the optional island trim or optional 6 or 9 inch backguard must be installed before sliding the range into place. Install them according to the accompanying installation instructions.

Dacor DR30DI — Removing the Oven Door diagram (page 15)
Fig. 23 · Removing the Oven Door
  • Do not attempt to disengage the hinge catches with the door removed from the oven. The hinge springs could release causing personal injury.

Side Panel Removal on Model DR30DI[H]

Remove the 3 1/4” side panels if both the top and the front of the range will be self-rimmed (see pages 7 and 8). Remove them before sliding the range into place.

  • Do not lift or carry the oven door by the handle.
1. Open the door to its fully opened position.
1. Remove the two screws on the side of the range and the one just above the kick panel that hold the side panel in place.
2. Using a screwdriver, rotate the catch over the retaining arm on each hinge.
2. To remove, slide the panel toward the back of the range, off of the ball studs.
Dacor DR30DI — Side Panel Removal on Model DR30DI[H] diagram (page 15)
Fig. 24 · Side Panel Removal on Model DR30DI[H]
Dacor DR30DI — Side Panel Removal on Model DR30DI[H] diagram (page 15)
Fig. 25 · Side Panel Removal on Model DR30DI[H]
3. Lift the oven door to about a 15° angle from the vertical position.
Dacor DR30DI — Side Panel Removal on Model DR30DI[H] diagram (page 15)
Fig. 26 · Side Panel Removal on Model DR30DI[H]

Door Gripping Points

4. Hold the door with both hands just below the handle and pull it away from the oven while continuing to lift.
Page 16 of the Dacor DR30DI user manual — Types of Electrical Connections
Page 16 · click to enlarge
Page 16

Electrical Connection

Appliance Cord Connections - Where Local Code Permits

  • Wire the range only in compliance with local ordinances.

Do not connect the green appliance wire to the neutral (white) supply wire unless local building codes permit.

  • Before proceeding, turn off power to the electrical supply at the circuit breaker panel for fuse box. Do not turn on power to the range until instructed to do so in the Verifying Proper Operation section of these instructions.
1. Remove the range electrical access cover from the back of the range.
  • Improper connection of the electrical wiring can cause an electric shock hazard and damage the appliance. Dacor is not responsible for damages resulting from improper installation.
2. IMPORTANT: If using a 4-wire connection, loosen the grounding screw and remove the neutral to ground jumper link from the terminal block. Leave the link in place for 3-wire connections.
  • The ground terminal (or lead) on the appliance must be connected to a grounded, metallic, permanent wiring system or grounding conductor.
3. Remove the conduit bracket from the bottom of the range electrical box.
  • Do not use an extension cord with this appliance. Such use may result in fire, electric shock or other personal injury.
  • Do not install a fuse in the neutral or ground circuit. A fuse in the neutral or ground circuit may result in an electric shock hazard.

IMPORTANT:

  • Some models come pre-wired at the factory with a 4-wire appliance cord for connection to a 14-50R electrical receptacle as specified on page 3. If the range being installed is pre-wired, skip to Gas Connection on page 18. This section does not apply to pre-wired units.

Remove link on 4-wire installations

  • Do not disconnect any of the wires inside the range electrical box unless instructed to do so.
  • Make sure that the conduit or appliance cord is long enough to allow the range to be pulled out for service without disconnecting it from power.

Remove conduit bracket before strain relief installation

4. Disassemble and remove the strain relief from the appliance cord (not included). Insert the tabs on the two parts of the strain relief into the hole on the bottom of the box and reassemble it so that the tabs are below the box and the strain relief itself is inside the box.

Put slack in electrical wiring and gas line

Types of Electrical Connections

Dacor DR30DI — Types of Electrical Connections diagram (page 16)
Fig. 27 · Types of Electrical Connections

Refer to the product data label (see inside cover) for power requirements.

There are four possible ways to wire the range:

  • 4-wire appliance cord, where local codes permit
  • 3-wire appliance cord, where local codes permit
  • 4-wire conduit (see page 16)
  • 3-wire conduit, where local codes permit (see page 16)

The sections on the following pages give directions for connecting each type of wiring harness.

Reassemble with tabs below and clamp above Bottom of range electrical box

Terminal block

Page 17 of the Dacor DR30DI user manual — 3-wire Appliance Cord Connection - Where Local Code Permits
Page 17 · click to enlarge
Page 17
Dacor DR30DI — 3-wire Appliance Cord Connection - Where Local Code Permits diagram (page 17)
Fig. 28 · 3-wire Appliance Cord Connection - Where Local Code…
5. Slide the end of the appliance cord into the strain relief from the bottom of the box.
6. Connect the white (neutral) wire to the neutral terminal in the box.
7. Connect the L1 wire to the L1 power supply terminal in the box.
8. Connect the L2 wire to the L2 power supply terminal in the box.
9. If using a 4-wire connection, connect the ground wire to the grounding screw inside the box using a loop or spade terminal.
10. Tighten the strain relief so that the appliance cord is held snuggly in place.

3-wire Appliance Cord Connection - Where Local Code Permits

14-50P Plug

Page 18 of the Dacor DR30DI user manual — 3-Wire Conduit Connection - Where Local Code Permits
Page 18 · click to enlarge
Page 18

Electrical Connection (cont.)

Connecting Conduit to the Range

Do not connect the green appliance wire to the neutral (white) supply wire unless local building codes permit.

1. Remove the range electrical access cover from the back of the range.
2. IMPORTANT: If using a 4-wire connection, loosen the grounding screw and remove the neutral to ground jumper link from the terminal block. Leave the link in place for 3-wire connections.

Neutral to ground jumper link removed

Remove link on 4-wire installations

3. Remove the nut from the conduit strain relief (not included).

4-Wire Conduit Connection

4. Slide the wires and the end of the strain relief into the hole on the bottom of the range electrical box.

(preferred)

5. Before connecting the wires, slide the strain relief nut over the wires and thread it onto the conduit strain relief inside the box. Tighten into place.
6. Connect the white wire to the neutral terminal in the box.
7. Connect the black wire to the L1 power supply terminal.
8. Connect the red wire to the L2 power supply terminal.
9. If using a 4-wire connection, connect the green wire to the grounding screw inside the box.

Loop and spade terminal connections

10. Replace the range electrical access cover.

3-Wire Conduit Connection - Where Local Code Permits

Show 22 more labels / short text on this page
L1 terminal · Neutral terminal · L2 terminal · Grounding screw · Red wire · Green wire · White wire · Black wire · Terminal block · Conduit strain · relief nut · L1 terminal · Neutral terminal · Neutral to ground · jumper link · L2 terminal · Bare wire connections · Black wire · White wire · Red wire · Conduit strain · relief nut
Page 19 of the Dacor DR30DI user manual — 3-Wire Conduit-Junction Box Connection with External Ground
Page 19 · click to enlarge
Page 19

Connecting the Conduit to the House Electrical Junction Box

Dacor DR30DI — Connecting the Conduit to the House Electrical Junction Box diagram (page 19)
Fig. 29 · Connecting the Conduit to the House Electrical Junct…
Dacor DR30DI — Connecting the Conduit to the House Electrical Junction Box diagram (page 19)
Fig. 30 · Connecting the Conduit to the House Electrical Junct…
  • Do not ground the appliance to a gas supply pipe or hot water pipe.
  • Do not turn on power to the appliance without it being permanently grounded.
  • A grounded cold water pipe must have metal continuity to electrical ground and must not be interrupted by insulating materials. Any insulating materials must be jumpered with a length of No. 4 copper wire securely clamped to bare metal at both ends.

No. 4 copper wire

Dacor DR30DI — Connecting the Conduit to the House Electrical Junction Box diagram (page 19)
Fig. 31 · Connecting the Conduit to the House Electrical Junct…

Separate No. 10 (minimum)

Dacor DR30DI — Connecting the Conduit to the House Electrical Junction Box diagram (page 19)
Fig. 32 · Connecting the Conduit to the House Electrical Junct…

Insulated Pipe Jumper

1. With the range positioned directly in front of the cabinet cutout, feed the appliance wires into the junction box. Depending upon local codes, utilize one of the three (3) methods shown to connect the appliance to the junction box.

3-Wire Conduit-Junction Box Connection with External Ground

Dacor DR30DI — 3-Wire Conduit-Junction Box Connection with External Ground diagram (page 19)
Fig. 33 · 3-Wire Conduit-Junction Box Connection with External…
2. Connect the white wire from the appliance to the neutral (white) supply wire in the junction box.
3. Connect the black wire from the appliance to the black (L1) power supply wire in the junction box.
4. Connect the red wire from the appliance to the red (L2) power supply wire in the junction box.
5. If using a 4-wire connection, connect the green wire to a grounded supply wire in the junction box or to a grounded cold water pipe. If connecting to a grounded cold water pipe:

◊ Use a separate copper grounding wire (No. 10 minimum) to connect to the cold water pipe by means of a clamp and an external grounding connector screw.

◊ If there are any materials that isolate the cold water pipe from ground, jumper it with a No. 4 copper wire, clamped on both ends.

6. Replace the junction box cover.

Bare metal

Page 20 of the Dacor DR30DI user manual — Anti-Tip Foot Location
Page 20 · click to enlarge
Page 20

Gas Connection

Final Installation

1. Peel the protective plastic coating off of the range, including the range door.
  • Make sure the gas supply valve is off and that the power to the range is turned off at the circuit breaker or fuse box prior to connecting the gas line.
2. Measure from the floor to the countertop.
3. Adjust the leveling legs:

On freestanding units, adjust the leveling legs as required to position the trim around the edge of the cooktop even with or above the countertop.

  • Do not apply excessive pressure when tightening gas connections and fittings.
  • Do not use Teflon tape or plumber’s putty on gas flex line connections.

On self-rimming units, adjust the leveling legs to position the bottom edge of the range top trim slightly above countertop height.

  • Check for gas leaks as instructed below before using the appliance. Do not use a flame to check for leaks.
  • For LP installations, the LP gas tank must have its own high pressure regulator. This is in addition to the pressure regulator provided with the range.
  • The maximum gas supply pressure to the regulator must never exceed 1/2 pound per square inch (psi) or 3.5 kPa.
  • The range and shut-off valve must be disconnected from the gas supply piping during any pressure testing exceeding 1/2 psi (3.5 kPa).
  • The range must be isolated from the gas supply piping by closing the shut-off valve during any pressure testing at or below 1/2 psi (3.5 kPa).
* Distance to floor2 7/8” (7.3 cm)

to 5” (12.7 cm)

  • Be careful not to damage the wires inside the chassis while pushing the gas line through the access holes.
4. Locate the anti-tip foot on the back of the range and lower (turn) it until it is 1/16” (2 mm) off the floor.

NOTE: The gas pressure regulator is pre-set at the factory for the type of gas intended for use with the appliance. To verify that the appliance is compatible with the type of gas available, check the product data label (see inside cover for location). Ranges intended for use with LP gas will have “LP” as a part of the model number. Consult your dealer if the range is not compatible with the type of gas supplied.

1. Make sure the gas supply valve is in the off position and power to the range is off.

Anti-Tip Foot Location

2. Connect a flexible gas supply line to the gas shut-off valve previously installed on the stub out. The gas line needs to be long enough to allow the range to be pulled out for service.
5. Carefully slide the range into position into the cutout. The anti-tip foot should engage the anti-tip bracket. Using a flashlight look underneath the range and verify that the bracket covers the anti-tip foot.
3. Slide the gas line up through the access holes in the chassis and up to the regulator. Move the wires around inside the access holes to prevent them from catching on the gas line as you push it up.
Dacor DR30DI — Anti-Tip Foot Location diagram (page 20)
Fig. 34 · Anti-Tip Foot Location
5. Turn all cooktop control valves to the OFF position.
6. Turn on the gas supply and check all lines and connections for leaks using a soap and water solution.
7. Turn the gas shutoff valve to the off position.
6. Use a level to make sure that the range does not tilt front to back or side to side. Re-adjust the legs to level and change the height if necessary.
Show 9 more labels / short text on this page
Back of range · 2 1/8” * · Rear leg · down · up · Back of · range · Anti-tip · foot
Page 21 of the Dacor DR30DI user manual — SimmerSear Burner
Page 21 · click to enlarge
Page 21

Re-installing the Oven Door

Cooktop Assembly

To avoid personal injury or damage to the door from it falling off its hinges:

Never attempt to operate the range’s cooktop with any of the burner rings, burner caps or grates removed.

  • Make sure that the notch on the bottom of each hinge rests on top of the lower lip of each hinge receptacle before attempting to open the oven door.
1. Remove the burner rings, burner caps and grates from their shipping packages.
  • Rotate the hinge locks toward the front of the range immediately after installation of the door.
2. Assemble the burners and grates as shown below.

1. Grasp the oven door on opposite sides and hold it at a 15° angle from the front of the oven. Slide the hinges into the hinge openings, resting the bottom of the hinge arms on the hinge receptacles. Continue to hold the door at a 15° angle with one hand while pushing in on each of the bottom corners of the door. Push until the notch on the bottom of each hinge slips over the lower lip of each hinge receptacle.

2. Lower the door to the fully opened position.
3. Rotate the two hinge locks toward the oven.
4. Slowly and carefully open and close the door completely to ensure that it is properly installed.
5. Remove any packaging from inside the oven.

Ridge on bottom of on inner burner cap

Ridge on bottom of burner cap

Notch on bottom of hinge

Door Installation

Igniter on burner base

SimmerSear Burner

Standard Burner

Assembly

Assembly

Show 18 more labels / short text on this page
Grates · Standard burners · SimmerSear burner · Spill tray · Inner burner · cap · Outer burner · cap · Lower lip · Burner · Igniter · of hinge receptacle · ring · hole · Burner · ring · Pin on burner · base
Page 22 of the Dacor DR30DI user manual — BAKE
Page 22 · click to enlarge
Page 22

Verifying Proper Operation

3. Repeat the bake test or burner ignition test.
4. If the appliance still does not work, contact Dacor Distinctive Service at (877) 337-3226. Do not attempt to repair the appliance yourself. Have the model and serial numbers available when you call. See inside cover for location.
  • Before operating the range, read the accompanying use and care manual completely.

Dacor is not responsible for the cost of correcting problems caused by a faulty installation. Installation Checklist

  • Make sure that power to the range is turned off at the circuit breaker or fuse box and that the gas is turned off at the gas supply valve before proceeding.
  • The cooktop must be properly grounded at all times when electrical power is applied.
1. Before beginning the test procedure, ensure that all cooktop control valves are in the OFF position, and all burner rings, burner caps and grates are properly positioned on the spill tray. Remove any packaging from inside the oven.

To ensure a safe and proper installation, the following checklist should be completed by the installer to ensure that no part of the installation has been overlooked.

□ □ Has the plastic coating been peeled off of the outside of the range? Have all packaging materials been removed from inside the oven?

2. Turn on the gas supply at the shut-off valve.
3. Plug in the appliance cord, if applicable. Turn on power to the range at the circuit breaker or fuse box.

□ □ Are all leveling legs extended down to make contact with the floor? Is the unit level? See page 18.

4. Perform the following ignition test for all of the burners:

◊ Push in and turn one of the control knobs counterclockwise to the HIGH position. Only the igniter for the selected burner will spark. It may take up to four seconds for the gas to ignite, at which time the igniter will stop sparking. If ignition does not occur within four seconds, turn the knob to the OFF position, wait for at least five minutes to allow any gas to dissipate, then repeat the test.

□ □ Is the range secured in place with the provided anti-tip bracket and foot according to these instructions? See page 10.

OFF HIGH LOW

□ □ Is the range wired and grounded according to these instructions and in accordance with all applicable electrical codes? Has the electrical access cover been replaced? See Pages 3 and 16.

□ □ Has the gas supply inlet pressure been measured to ensure that it does not exceed the maximums stated in these instructions? See page 4.

◊ Once the burner lights, the control knob can be rotated counterclockwise from HIGH to LOW to adjust the flame height progressively.

□ □ Is the range connected to the gas supply according to these instructions and in accordance with all applicable codes? See page 18.

◊ When the unit is installed properly, the flame will be steady. It will also have a sharp, blue inner cone that will vary in length proportional to the burner size. The flame will be reduced by the Smart Flame™ feature under the grate fingers to increase grate life.

Dacor DR30DI — OFF HIGH LOW diagram (page 22)
Fig. 35

□ □ Did the installer check the gas supply for leaks?

□ □ Is the oven door properly installed according to these instructions? See page 19.

□ □ Are the burners and grates properly installed according to these instructions? See page 19.

□ □ Has proper operation been verified?

□ □ Has the warranty been activated on-line or the warranty card been filled out completely and mailed?

Normal Flame

5. Set the clock according to the use and care manual.
6. Press the BAKE key on the control panel. The default bake temperature should appear on the display.
7. Enter the temperature of 350°F on the keypad.
8. Press START . The display should show the BAKE symbol and the preheating temperature.

BAKE

9. After approximately three (3) minutes, the oven should begin to heat. Press the CANCEL-SECURE key to stop the oven heating process.
1. Verify that power and gas are supplied to the range.
2. Check the electrical connections and gas supply to ensure that the installation has been completed correctly.
Page 23 of the Dacor DR30DI user manual — Gas Connection
Page 23 · click to enlarge
Page 23
Page 23 of the Dacor DR30DI user manual — Gas Connection
Page 24 of the Dacor DR30DI user manual — Gas Connection
Page 24 · click to enlarge
Page 24
  • Dacor
  • 14425 Clark Avenue, City of Industry, CA 91745
  • Phone: (800) 793-0093
  • Fax: (626) 403-3130
  • <a href="http://www.dacor.com" rel="nofollow noopener" target="_blank">www.dacor.com</a>

Ask about the Dacor DR30DI

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Dacor DR30DI

Be the first to ask — other owners or our team will answer.

Original document

Dacor DR30DI manual PDF

24 pages·4 MB·Range·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…