EN
Dacor logo
Official user manual

Dacor DHI482

16 pages·1.1 MB·Ventilation Hood·PDF·ENDEFRITNLJA
Dacor DHI482
Table of Contents 53 sections DHI361 · DHI421 · DHI482 · DHI542 · … ShowHide
DHI361p.1DHI421p.1DHI482p.1DHI542p.1DHI602p.1T able of C ontentsp.2B efore Y ou B egin ... IMPORTANT:p.2I mportant S afety I nstructions Important Information About Safety Instructionsp.3Safety Symbols and Labelsp.3DANGERp.3CAUTIONp.3READ AND SAVE THESE INSTRUCTIONsp.3I mportant S afety I nstructionsp.4P roduct S pecificationsp.5G eneral S pecificationsp.5D imensionsp.5ALL MODELSp.5MODEL SPECIFICp.5P reparing for I nstallation V erify the P ackage C ontentsp.6P reparing for I nstallationp.7E lectrical P ower S upplyp.7Electrical Specificationsp.7P lanning the L ocationp.7Preparing the Mounting Bracket Locationp.7P lan the D uct W ork I nstallationp.8Calculating the Maximum Duct Run Lengthp.8Duct Work Equivalent Lengthsp.8Duct Work Design Tipsp.8A ssemble the H oodp.9H ood A ssembly ( cont )p.10HOOD JUNCTIONp.10BOXp.10FRAMEWORKp.10BOTTOMp.10HOODp.10EXTERNALp.10MOTOR TERMINALp.10BLOCKp.10H anging the R ange H oodp.12I nstall the D uct W orkp.12I nstallation I nstructions F inal E lectrical I nstallationp.13F inal C himney A ssemblyp.13WARNINGSp.13V erifying P roper O perationp.14I nstallation C hecklistp.14Is the mounting bracket properly attached to the ceiling □ □p.14Is the hood properly secured to the mounting bracket □ □p.14Is the duct work completely installed? Are all joints □ □p.14If the hood fails to operate properly:p.14Is the range hood wired and grounded according to □ □p.14Are the filters properly installed according to the use □ □p.14Has proper operation □ □ been verified?p.14Have any problems been noted on the warranty card □ □p.14
Page 1 of the Dacor DHI482 user manual — DHI361
Page 1 · click to enlarge
Page 1

Installation Instructions Millennia™ Island (Ceiling Mount) Range Hoods

For use with models:

DHI361

DHI421

DHI482

DHI542

DHI602

Part No. 101744 Rev. B

Page 2 of the Dacor DHI482 user manual — B efore Y ou B egin ... IMPORTANT:
Page 2 · click to enlarge
Page 2

T able of C ontents

Installation Instructions 7-12 Electric Service Installation 7 Mounting Bracket Installation 7 Assemble the Hood 7 Hanging the Range Hood 10 Install the Duct Work 10 Final Electrical Installation 11 Final Chimney Assembly 11 Verifying Proper Operation 12 Installation Checklist 12

B efore Y ou B egin ... IMPORTANT:

If you have questions or problems with installation, contact your Dacor dealer or the Dacor Customer Service Team.

INSTALLER • : In the interest of safety and to minimize problems, read these installation instructions completely and carefully before you begin the installation process. Leave these installation instructions with the customer.

Dacor Customer Service Team

Phone(800) 793-0093
Web sitewww.Dacor.com

CUSTOMER • : Keep these installation instructions for future reference and the local electrical inspector’s use.

All specifications are subject to change without notice. Dacor assumes no liability for changes to specifications.

© 2007 Dacor, all rights reserved

Page 3 of the Dacor DHI482 user manual — READ AND SAVE THESE INSTRUCTIONs
Page 3 · click to enlarge
Page 3

I mportant S afety I nstructions Important Information About Safety Instructions

Safety Symbols and Labels

DANGER

The Important Safety Instructions and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance.

Immediate hazards which WILL result in severe personal injury or death.

Hazards or unsafe practices which COULD result in severe personal injury or death.

Always contact the Dacor Customer Service Team about problems and conditions that you do not understand.

CAUTION

Hazards or unsafe practices which COULD result in minor personal injury or property damage.

DANGER

  • Do not use or light any appliance.
  • Do not touch any electrical switch or use any electrical devices, including the telephone, in your building.
  • From a neighbor’s phone, immediately call the gas supplier. Follow the gas supplier’s instructions.
  • If you cannot contact the gas supplier, call the fire department.

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

b) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to

prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

READ AND SAVE THESE INSTRUCTIONs

Page 4 of the Dacor DHI482 user manual — I mportant S afety I nstructions
Page 4 · click to enlarge
Page 4

I mportant S afety I nstructions

To reduce the risk of fire, electric shock, serious injury or death when using your range hood, follow basic safety precautions, including the following:

Do not 1. install or operate this hood if it has been damaged, dropped, has damaged electrical conduit or wires or is not working properly. If the product is damaged when received, immediately contact the dealer or builder.

Use this range hood only for its intended purpose as outlined in the use and care manual. 2. Do not use this range hood to vent hazardous or explosive materials or vapors. If you have questions, contact the manufacturer.

The customer should not install, repair or replace any part of the range hood unless specifically recommended in 3. the literature accompanying it. A qualified service technician should perform all other service. Contact the nearest Dacor authorized service representative at (800) 793-0093, or at www.Dacor.com for examination, repair or adjustment.

Keep all packaging materials away from children. Plastic bags can cause suffocation. 4.

This range hood must be installed and grounded by a qualified installer according to these installation 5. instructions. All installation work and electrical wiring must be performed in accordance with all applicable codes and standards, including fire-rated construction.

Install or locate this appliance only in accordance with these installation instructions and the requirements 6. specified by the manufacturer of the cooktop or range. Improper installation, adjustment, alteration, service or maintenance can cause serious personal injury or property damage.

Do not use an extension cord or adapter plug with this appliance. 7.

Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning 8. equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utilities. 9.

The installer must show the customer the location of the fuse or junction box so that the customer knows where 10. and how to turn the power off.

Before installing or servicing the range hood, switch power off at the fuse or junction box and lock the electrical 11. panel door to prevent power from being switched on accidentally. When the electrical panel cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

Read the use and care manual completely before using the appliance. 12.

Do not tamper with the controls. 13.

Never allow the filter(s) to become blocked or clogged. Do not allow foreign objects, such as cigarettes or 14. napkins, to be sucked into the hood.

Clean the filter(s) and all grease-laden surfaces often to prevent grease fires and maintain performance. 15.

If the cooktop and range hood are near a window, use an appropriate window treatment. Avoid long drapes or 16. other window coverings that could blow over the cooktop and hood, resulting in a fire hazard.

Always run the blower(s) whenever the cooktop is operating. 17.

Never leave the range or cooktop unattended when a burner (or element) is in use. Boil-overs and greasy spills 18. may smoke and/or ignite.

Do not leave children alone or unattended in the area where the cooktop and range hood are in use. Never allow 19. children to sit or stand on an appliance. Do not let children play with a range, cooktop or range hood. Do not store items of interest to children above or around the cooktop, range or range hood.

The minimum vertical distance between the cooktop surface and the exterior part of the hood must be no less 20. than 30” (762 mm). The vertical distance may be longer for the range or cooktop being used. Consult the range or cooktop installation instructions for the minimum and maximum vertical distance from the appliance being used.

A minimum of two people are required to safely install this appliance. 21.

Page 5 of the Dacor DHI482 user manual — MODEL SPECIFIC
Page 5 · click to enlarge
Page 5

I mportant S afety I nstructions

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE: 22.

SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray, then turn off the burner. BE CAREFUL a.

TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

NEVER PICK UP A FLAMING PAN - you may be burned. b.

DO NOT USE WATER, including wet dish cloths or towels - a violent steam explosion may result. c.

Use a fire extinguisher ONLY if: d.

You have a Class ABC extinguisher, and you already know how to operate it. •

The fire is small and contained in the area where it started. •

The fire department is being called. •

You can fight the fire with your back to an exit. •

P roduct S pecifications

G eneral S pecifications

D imensions

Tolerances+1/16”, -0 (+1.6 mm, -0), unless otherwise stated

ALL MODELS

15 ¾” (40.0 cm)

12 9/16” (31.9 cm)

Dacor DHI482 — ALL MODELS diagram (page 5)
Fig. 1
Blower600 CFM (1200 for units with 2 blowers) with electronic speed control Blower Speeds4 Lights12 Vac, 20 W halogen FiltersBaffle type, dishwasher safe Exhaust8-inch Finish430 stainless steel Voltage120 Vac, 60 Hz (see below for current rating) Circuit Requirement120 Vac, 15 Amp grounded, dedicated circuit, minimum
Dacor DHI482 — ALL MODELS diagram (page 5)
Fig. 2

MODEL SPECIFIC

Dacor DHI482 — MODEL SPECIFIC diagram (page 5)
Fig. 3
SPECIFICATION MODELBlowersLightsFiltersMaximum Current Draw DHI3611413.75 A DHI4211413.75 A DHI4822426.75 A DHI5422627.10 A DHI6022637.10 A

36” (91.4 cm) - 42” (106.7 cm) 48” (121.9 cm) - 54” 137.2 cm) 60” (152.4 cm)

* 18” 1/4 on models DHI482, DHI542 and DHI602

** 30” on models DHI482, DHI542 and DHI602

Page 6 of the Dacor DHI482 user manual — D
Page 6 · click to enlarge
Page 6

P reparing for I nstallation V erify the P ackage C ontents

Unpack the parts box and verify that all required components have been provided. If any item is missing or damaged, please contact the dealer immediately. Do not install a damaged or incomplete appliance.

Dacor DHI482 — P reparing for I nstallation V erify the P ackage C ontents diagram (page 6)
Fig. 4 · P reparing for I nstallation V erify the P ackage C…

Hood assembly with filter(s)

A

Chimney assembly (2 piece)

B

Blower exhaust cowling (2 blower units only)

D

Framework assembly (2 piece)

E

Mounting and assembly hardware

F

Use and care manual

G

Make sure you have everything necessary for proper installation before proceeding.

B

Dacor DHI482 — B diagram (page 6)
Fig. 5
Dacor DHI482 — B diagram (page 6)
Fig. 6

D

F

G

Mounting bracket

Page 7 of the Dacor DHI482 user manual — Preparing the Mounting Bracket Location
Page 7 · click to enlarge
Page 7

P reparing for I nstallation

E lectrical P ower S upply

The electrical service to the range hood should be • installed only by a licensed electrician.

Electrical Specifications

It is the owner’s responsibility to ensure that the electrical connection of this appliance is performed by a qualified electrician. The electrical installation, including minimum supply wire size and grounding, must be in accordance with the National Electric code ANSI/NFPA* (or latest revision) and local codes and ordinances.

Observe all governing codes and ordinances during • planning and installation. Contact your local building department for further information.

DO NOT • use the mounting anchors provided with the unit. They are part of a standard mounting hardware package provided with many Dacor hoods, but not suitable for use with this model.

Connect the hood to a 120 Vac, 60 Hz dedicated, grounded, circuit protected by a 15 Amp circuit breaker or time delay fuse.

The range hood is heavy. To prevent personal injury • and property damage caused by the hood coming loose from the ceiling, mount the hood mounting bracket only as specified below.

*A copy of this standard may be obtained from:

National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101

P lanning the L ocation

Carefully check the location where the hood is to be • installed. The hood should be placed for convenient access. Make certain that electrical power can be provided in the selected location.

Install the range hood and cooking appliance(s) so that • they can be removed if service is required.

Plan the installation so that all minimum dimensions • are met or exceeded (see page 3). Dimensions shown provide minimum clearances, unless otherwise noted.

Preparing the Mounting Bracket Location

The mounting bracket must be attached directly to the • studs in the ceiling, or to a reinforced mounting block secured to the studs. See below for mounting bracket hole dimensions.

12 9/16” (31.9 cm)

11” (27.9 cm)

6 1/8” (15.6 cm)

Attach the mounting bracket directly above the center • of the cooktop.

Attach the mounting bracket to the mounting surfaces • with #12 screws (not supplied). The screws must be of sufficient length to penetrate into the wood mounting surfaces at least 1 1/2” (3.8 cm).

The mounting surface must be level. •

Allow clearance in the center of the mounting bracket • for the exhaust duct to pass through the ceiling (8-inches in diameter).

Page 8 of the Dacor DHI482 user manual — Duct Work Design Tips
Page 8 · click to enlarge
Page 8

P reparing for I nstallation

P lan the D uct W ork I nstallation

Calculating the Maximum Duct Run Length

The maximum straight duct length for the hood is 100 feet. For each elbow and transition added to the duct work, a certain number of feet must be subtracted from the maximum straight length to compensate for wind resistance. To determine the length the duct work cannot exceed, subtract all of the equivalent lengths of the elbows and transitions listed below from 100 feet.

To reduce the risk of fire and to properly exhaust • air, be sure to duct air outside the house or building. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages.

Tape all duct joints securely • to prevent combustion by-products, smoke or odors from entering the home. Doing so will also improve system efficiency.

Duct Work Equivalent Lengths

Do not exhaust more than one • vent into a single duct.

DUCT PIECESUBTRACT 90° elbow (8” Dia.)7 feet 45° elbow (8” Dia.)3 feet 3 1/4” x 10” to 8” round4 foot Wall cap with damper30 feet Roof cap30 feet

Use only • duct work constructed of materials deemed acceptable by state, municipal and local codes.

Range hoods may interrupt the proper flow of • smoke and combustion gases from furnaces, gas water heaters and fireplaces. To avoid drawing lethal gases into the home, follow the manufactures recommendation for these devices and consult NFPA and ASHRAE recommendations.

Duct Work Design Tips

DO NOT • install an additional in-line or external blower to increase the length of the duct run. Even small differences between blower air flow rates can greatly reduce the air draw by the hood.

Wherever possible, reduce the number of transitions • and turns to as few sharp angles as possible. Two staggered 45° angles are better than one 90°.

Keep turns as far away from the hood exhaust as • possible, with as much space between each bend as possible.

All duct work materials (including screws and duct tape) • must be purchased separately by the customer. When planning new duct work, always look for the shortest, most direct route to the outside.

For best performance, use round duct instead of • rectangular, especially when elbows are required.

The hood exhaust connects to an 8-inch round duct. • You can increase the duct size over the duct run if desired. To prevent a back draft, never decrease the duct size over the run.

If multiple elbows are used, try to keep a minimum of • 24” (61 cm) of straight duct between them.

Avoid “S” or “back to back” configurations of adjacent • elbows.

Do not rely on duct tape alone to seal duct joints. • Fasten all connections with sheet metal screws and tape all joints with duct tape. Use sheet metal screws as require to support the duct weight.

In regions where the weather gets extremely cold, • thermal breaks, such as a short section of non-metallic duct, should be used to avoid indoor heat loss. The break should be located as close to the pass through point to the outside as possible.

To prevent back-drafts, a damper at the duct outlet may • also be required.

Make sure duct work does not interfere with floor joists • or wall studs.

Do not use flexible metal duct. •

Do not • use duct work that is smaller in cross-sectional area than the recommended size duct (8” round).

Page 9 of the Dacor DHI482 user manual — A ssemble the H ood
Page 9 · click to enlarge
Page 9

A ssemble the H ood

Do not install the range hood unless the electrical • service provided meets the range hood specifications.

Lifting and hanging the range hood requires two • people. Do not attempt to lift the hood without assistance.

Observe all governing codes and ordinances during • planning and installation. Contact your local building department for further information.

Place the hood assembly on a soft surface with the 1. bottom side down during assembly to avoid damage.

A qualified technician must complete the installation • of this built-in appliance. The owner is responsible to make sure the hood is properly installed.

To avoid an electric shock hazard and property • damage, locate electric wires and water pipes and avoid drilling in the vicinity.

Inside the exhaust outlet(s) there are metal or plastic 3. damper flaps. The flaps close to help prevent back- drafts when the blower is turned off. Make sure all the flaps open and close freely before proceeding. Remove any shipping tape that may be present.

The range hood is heavy. To prevent personal • injury and property damage install the hood only as specified below. Make sure all screws used to mount and assemble the hood are tight. Electric Service Installation

The electrical connection box must be:

Connected to a 120 Vac, 60 Hz dedicated, grounded, • circuit protected by a 15 Amp circuit breaker or time delay fuse.

Located a minimum of 17” (43.2 cm) above the bottom • of the range hood. Mounting Bracket Installation

Remove the tape that holds the wiring in place on top 4. of the hood during shipment.

Locate the mounting bracket and position it against the 1. ceiling at the previously determined mounting location (see page 5).

On models with two blowers: Put the exhaust cowling 5. over the blower outlets on the top of the hood. Fasten the cowling in place with 14 machine screws.

Using a pencil, mark the four mounting hole locations 2. on the ceiling.

Drill four 1/16” (1.6 mm) pilot holes at the mounting 3. hole locations.

Dacor DHI482 — A ssemble the H ood diagram (page 9)
Fig. 7 · A ssemble the H ood

Attach the bracket using four #12 screws (not 4. supplied). Make sure the screws penetrate into the wood mounting surfaces 1 1/2” (3.8 cm).

Dacor DHI482 — A ssemble the H ood diagram (page 9)
Fig. 8 · A ssemble the H ood
Page 10 of the Dacor DHI482 user manual — BOTTOM
Page 10 · click to enlarge
Page 10

H ood A ssembly ( cont )

Separate the bottom framework piece from the top 6. framework piece. The top frame work piece has 5-inch slots on the the sides. The bottom piece has a series of holes on the sides.

Attach the hood junction box to the rim of the bottom 9. framework piece using two machine screws as shown.

Position the bottom framework piece on top of the 7. hood. Slide the studs on the top of the hood into the holes on the bottom of the framework piece. The cut- outs for the wiring allow the bottom framework piece to fit on only one way. If it does not fit properly, turn it 180° so that the cut-outs line up. Make sure all wiring is tucked inside the framework piece and are not pinched.

HOOD JUNCTION

BOX

FRAMEWORK

Attach the external motor terminal block to the rim of 10. the bottom framework piece using two machine screws as shown. It mounts on the opposite side of the hood junction box.

BOTTOM

HOOD

EXTERNAL

MOTOR TERMINAL

BLOCK

Use eight provided lock washers and nuts to secure the 8. bottom framework piece to the top of the hood.

Page 11 of the Dacor DHI482 user manual — H ood A ssembly ( cont )
Page 11 · click to enlarge
Page 11

Determine the 11. required framework height. To deter- mine the required framework height:

Dacor DHI482 — H ood A ssembly ( cont ) diagram (page 11)
Fig. 9 · H ood A ssembly ( cont )

Measure the distance from the ceiling to the • cooktop.

Subtract the height at which the hood will be • mounted (30” minimum) and the hood thickness (12 1/2”) from the distance measured.

Put the top framework piece over the bottom framework 12. piece. The mounting slots on the top piece must be up.

Use four machine screws to fasten the top piece to 13. the bottom piece. The total height of the two pieces together must equal the required framework height determined above.

Remove the protective plastic covering from both 14. pieces of the chimney assembly. Do not remove the protective tape strips from the inside. They protect the telescoping pieces from scratching during installation.

Carefully slide both sections together so that only the 15. vents on the top section show.

Hold the chimney vertically with the vents up. 16.

Carefully put the chimney over the top of the 17. framework, taking care not to scratch the surfaces. Make sure the Dacor logo faces the same side as the control panel.

Make sure any wires are tucked in behind the chimney 18. and are not pinched.

Page 12 of the Dacor DHI482 user manual — H anging the R ange H ood
Page 12 · click to enlarge
Page 12

H anging the R ange H ood

I nstall the D uct W ork

Dacor DHI482 — H anging the R ange H ood diagram (page 12)
Fig. 10 · H anging the R ange H ood

To prevent personal injury, do not rely on the • mounting springs to hold the hood assembly in place on the ceiling. Once the hood is hooked in place IMMEDIATELY secure the framework to the mounting bracket as described below.

Do not use screws to attach the duct work to the • hood exhaust outlet. Use duct tape only. Screws may prevent the damper flaps on the top of the hood from opening.

Install the duct work system. Lift the chimney up • and reach inside the framework to access the hood exhaust. Attach the duct to the hood exhaust with duct tape alone. Use sheet metal screws (not provided) and duct tape on all the remaining duct system joints.

Before raising the hood into position, lift it up and orient 1. it so that the control panel faces the same direction as the front of the cooktop or range.

Lift the hood assembly up on both sides and slip the 2. end of the framework over the mounting bracket. Push up until all four mounting springs protrude out of the mounting slots on the top of the framework.

duct work through ceiling, connects to exhaust outlet inside framework

Dacor DHI482 — H anging the R ange H ood diagram (page 12)
Fig. 11 · H anging the R ange H ood

Attach the framework to the mounting bracket using 3. four self-tapping screws.

Dacor DHI482 — H anging the R ange H ood diagram (page 12)
Fig. 12 · H anging the R ange H ood
Page 13 of the Dacor DHI482 user manual — WARNINGS
Page 13 · click to enlarge
Page 13

I nstallation I nstructions F inal E lectrical I nstallation

F inal C himney A ssembly

WARNINGS

To avoid electrical shock or fire hazard, make sure • the power supply at the fuse or junction box is turned off before proceeding with final electrical installation.

Move the chimney up toward the ceiling. Line up the 1. holes on the side of the chimney, above the vents, with the holes on the side of the mounting bracket.

Improper connection of the hood electrical wiring may • create an electric shock or fire hazard and may result in damage to the hoods electrical system.

Do not ground the hood to the neutral (white) power • supply wire. Connect the hood ground wire to a separate, properly grounded wire installed by a licensed electrician.

Connect the house power supply wires to the wires coming out of the hood junction box, inside the chimney:

Connect the white wire from the hood to the neutral 1. (white) power supply wire.

Connect the black wire from the hood to the hot (black) 2. power supply wire.

Connect the green and yellow wire from the hood to 3. the house ground (green) wire from the junction box.

Attach the sides of the chimney to the bracket using 2. two machine screws, one on each side.

Carefully, slide the bottom portion of the chimney down 3. until it rests on the top of the range hood.

Reinstall the range hood filter(s) before operation.

black to black · white to white · Yellow/green to green

Page 14 of the Dacor DHI482 user manual — Has proper operation □ □ been verified?
Page 14 · click to enlarge
Page 14

V erifying P roper O peration

I nstallation C hecklist

Turn on power at the junction or fuse box. 1.

If the control panel is not lit, remove the filter(s) and 2. turn on the main power switch located behind the filters on the underside of the hood. Replace the filter(s).

To ensure a safe and proper installation, the following • checklist should be completed by the installer to ensure that no part of the installation has been overlooked.

Touch the light key. Verify that all the lights come on. 3.

Touch the light key again to turn the lights off. 4.

Proper installation is the responsibility of the • homeowner. The importance of proper installation of your Dacor range hood cannot be overemphasized.

Touch the blower 5. “+” key once and release. Verify that one light is showing on the blower speed indicator and that the blower is on at low speed.

Is the mounting bracket properly attached to the ceiling □ □

Touch and release the blower 6. “+” repeatedly, three times. Verify that with each touch of the key the number of lights on the blower speed indicator increases and that the blower speed increases.

according to the instructions on page 7?

Is the hood properly secured to the mounting bracket □ □

with the machine screws (see page 10)?

Is the duct work completely installed? Are all joints □ □

Touch and hold the blower 7. “-” key until the blower turns off.

attached with sheet metal screws and wrapped with duct tape (see pages 6 and 10)?

If the hood fails to operate properly:

Is the range hood wired and grounded according to □ □

Verify that power is supplied to the hood. •

these instructions and in accordance with all applicable electrical codes (see page 11)?

Check the electrical connections to ensure that the • installation has been completed correctly.

Are the filters properly installed according to the use □ □

Repeat the above test. •

If the appliance still does not work, contact an • authorized Dacor service company at (800) 793-0093.

Has proper operation □ □ been verified?

Have any problems been noted on the warranty card □ □

Do not attempt to repair the appliance yourself. Dacor is not responsible for service required to correct a faulty installation.

or during the on-line warranty activation? Has the warranty been activated on-line or the warranty card filled out completely and mailed?

and care manual?

Page 15 of the Dacor DHI482 user manual — V erifying P roper O peration
Page 15 · click to enlarge
Page 15
Page 15 of the Dacor DHI482 user manual — V erifying P roper O peration
Page 16 of the Dacor DHI482 user manual — V erifying P roper O peration
Page 16 · click to enlarge
Page 16
  • Dacor
  • 1440 Bridge Gate Drive, Diamond Bar, CA 91765
  • Tel: (800) 793-0093
  • FAX: (626) 403-3130
  • <a href="http://www.Dacor.com" rel="nofollow noopener" target="_blank">www.Dacor.com</a>

Ask about the Dacor DHI482

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Dacor DHI482

Be the first to ask — other owners or our team will answer.

Original document

Dacor DHI482 manual PDF

16 pages·1.1 MB·Ventilation Hood·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…