Page 1 of the Agilent Technologies E5805A user manual — Agilent E5805A USB/RS232 Interface for Windows - 4 Port Agilent USB/RS232 Interface
Page 1 · click to enlarge
Page 1
Agilent Technologies E5805A diagram (page 1)
Fig. 1

Agilent E5805A USB/RS232 Interface for Windows - 4 Port Agilent USB/RS232 Interface

Agilent USB/RS232 Interface for Windows® - 4 Port

E5805A Installation

Guide

Agilent Technologies

Page 2 of the Agilent Technologies E5805A user manual
Page 2 · click to enlarge
Page 2
Page 2 of the Agilent Technologies E5805A user manual
Page 3 of the Agilent Technologies E5805A user manual — Restricted Rights Legend
Page 3 · click to enlarge
Page 3

Notices

© Agilent Technologies, Inc. 2007

Warranty

receive no greater than Restricted Rights as defined in FAR 52.227-19(c)(1-2) (June 1987). U.S. Government users will receive no greater than Limited Rights as defined in FAR 52.227-14 (June 1987) or DFAR 252.227-7015 (b)(2) (November 1995), as applicable in any technical data.

No part of this manual may be reproduced in any form or by any means (including elec- tronic storage and retrieval or translation into a foreign language) without prior agree- ment and written consent from Agilent Technologies, Inc. as governed by United States and international copyright laws.

The material contained in this docu- ment is provided “as is,” and is sub- ject to being changed, without notice, in future editions. Further, to the max- imum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a par- ticular purpose. Agilent shall not be liable for errors or for incidental or consequential damages in connec- tion with the furnishing, use, or per- formance of this document or of any information contained herein. Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the sep- arate agreement shall control.

Safety Notices

Manual Part Number

CAUTION

E5805-90001

Edition

A CAUTION notice denotes a haz- ard. It calls attention to an operat- ing procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met.

Second Edition, September 22, 2007

Agilent Technologies, Inc. 815 14th Street SW Loveland, CO 80537

Windows is a US Registered trademark of Microsoft Corporation.

USB-IF is a trademark of Universal Serial Bus Implementers Forum, Inc.

Technology Licenses

The hardware and/or software described in this document are furnished under a license and may be used or copied only in accor- dance with the terms of such license.

WARNING

A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly per- formed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated condi- tions are fully understood and met.

Restricted Rights Legend

If software is for use in the performance of a U.S. Government prime contract or subcon- tract, Software is delivered and licensed as “Commercial computer software” as defined in DFAR 252.227-7014 (June 1995), or as a “commercial item” as defined in FAR 2.101(a) or as “Restricted computer soft- ware” as defined in FAR 52.227-19 (June 1987) or any equivalent agency regulation or contract clause. Use, duplication or disclo- sure of Software is subject to Agilent Tech- nologies’ standard commercial license terms, and non-DOD Departments and Agencies of the U.S. Government will

Printed in Malaysia

Page 4 of the Agilent Technologies E5805A user manual — Contents
Page 4 · click to enlarge
Page 4

Contents

Table of Contents

Cabling the E5805A USB/RS232 Interface 2

Installing the USB Hub & E5805A USB/RS232 Drivers 3

Driver Installation For Windows XP 4 Driver Installation For Windows 2000 Users 4 Driver Installation For Windows 98, and Me Users 5

Interpreting the System Status Light 6

The E5805A USB/RS232 Interface Utility Program 7

For all Windows Operating Systems 7

Understanding the E5805 and USB Hubs 14

Support 16

Appendix A 17 Regulatory and Other Information 21 Japanese Version 23

Page 5 of the Agilent Technologies E5805A user manual — 1 Installation Guide for the Agilent USB/RS232 Interface
Page 5 · click to enlarge
Page 5

1 Installation Guide for the Agilent USB/RS232 Interface

E5805A USB/RS232 Interface 2 Installing the E5805A USB/RS232 Interface Drivers 3 Interpreting the System Status Light 6 The E5805A USB/RS232 Interface Utility Program 7 Understanding the E5805A and USB Hubs 14 Support 16

Page 6 of the Agilent Technologies E5805A user manual — Cabling the E5805A USB/RS232 Interface
Page 6 · click to enlarge
Page 6

The E5805A USB/RS232 Interface is an intelligent, stackable expansion module that connects to a PC or server running Windows® 98SE, Me, 2000, or XP via the Universal Serial Bus (USB), providing high- speed serial connectivity.

Cabling the E5805A USB/RS232 Interface

Agilent Technologies E5805A — Cabling the E5805A USB/RS232 Interface diagram (page 6)
Fig. 2 · Cabling the E5805A USB/RS232 Interface
Agilent Technologies E5805A — Cabling the E5805A USB/RS232 Interface diagram (page 6)
Fig. 3 · Cabling the E5805A USB/RS232 Interface

Type A Type B

Plug the Type A end of the USB cable into the USB port located in the back of your PC or into an available USB port on a standard hub. Plug the Type B end of the USB cable into the back of the E5805A USB/RS232 Interface.

If the drivers are not already installed, go to "Installing the E5805A USB/RS232 Interface” on the next page.

Page 7 of the Agilent Technologies E5805A user manual — Installing the E5805A USB/RS232 Interface Drivers
Page 7 · click to enlarge
Page 7

Installing the E5805A USB/RS232 Interface Drivers

The E5805A ships with the Driver and the Automation- Ready CDs. The Driver CD software must be installed for the product to operate. Once the Driver software is installed, the E5805A can be attached to a USB port. Your PC should be able to connect to it, and the four RS232 ports on the E5805A should appear as additional Windows® COM ports. These ports can be used by your PC to connect serial instruments and general purpose devices to the four port RS- 232 converter. The IO Libraries CD shipped with the E5805A allows you to use I/O libraries (for example VISA, VISA COM, and SICL) to do “instrument style” programming of instruments or devices. It also provides a suite of tools for connection management and interactive instrument control. If you are using VISA or other T&M specialized software to program instruments, or if you are using application software that does instrument control, you may want to also install the IO Libraries Suite.

Page 8 of the Agilent Technologies E5805A user manual — Driver Installation For Windows 2000
Page 8 · click to enlarge
Page 8

Driver Installation For Windows XP

1 You must be logged into an account with administrator privileges.

2 Insert the “Agilent Driver” CD into your CD- ROM drive.

3 After connecting the USB cable, the Found New Hardware Wizard appears. Click “Next,” and the drivers are automatically installed from the CD. There are multiple resources on the E5805A which have to be setup, so continue to install resources until the XP installation completes.

Driver Installation For Windows 2000

1 You must be logged into an account with administrator privileges.

2 Insert the “Agilent Driver” CD into your CD- ROM drive.

3 After connecting the USB cable, the Found New Hardware Wizard appears. Select “Install from a list or specific location (Advanced)” and click “Next”.

4 Select “Search for a suitable driver for my device” and click “Next”.

5 Select “Specify a location” and click “Next”.

6 Type in :\Win2k and click “OK”.

7 Confirm that Windows is pointing to <CD drive letter>:\ Win2k. Then click “Next”.

8 There are multiple resources on the E5805A which have to be setup, so continue to install resources until the Windows 2000 installation completes.

9 Windows then finishes installing the driver files.

10 Choose “Finish” to complete the driver installation.

Installation is complete when no more dialogs appear. Your new COM port(s), numbered sequentially following the existing ports in your system, are ready.

Page 9 of the Agilent Technologies E5805A user manual — Driver Installation For Windows 98SE and Me
Page 9 · click to enlarge
Page 9

Driver Installation For Windows 98SE and Me

1 Insert the "Agilent Driver" CD into your CD- ROM drive.

2 After connecting the USB cable, the Add New Hardware Wizard appears. Click "Next".

3 Select "Search for the best driver for your device" and click "Next".

4 Select "Specify a location" and type in <CD drive letter>:\ Win98. Then click "Next".

5 Confirm Windows is pointing to <CD drive letter>:\Win98. Click "Next". Windows then copies over the driver files.

6 Click "Finish" to complete the driver installation.

Installation is complete when no more dialogs appear. Your new COM port(s), numbered sequentially following the existing ports in your system, are ready.

Page 10 of the Agilent Technologies E5805A user manual — Interpreting the System Status Light
Page 10 · click to enlarge
Page 10

Interpreting the System Status Light

Red: This light signifies a loss of USB communication with the host. If the loss is due to unplugging the unit, when the unit is reconnected the light will blink red for a few moments before turning green. Otherwise, the light indicates a problem with the drivers, which may need to be reinstalled. The red light also blinks during installation. Once the installation is complete, it should stop blinking.

Amber: This light signifies serial port activity on the E5805A USB/RS232 Interface. The amber light may also flash briefly during installation.

Green: This light indicates the serial ports are successfully set up and the E5805A USB/RS232 Interface is operating normally.

Page 11 of the Agilent Technologies E5805A user manual — The E5805A USB/RS232 Interface Utility Program
Page 11 · click to enlarge
Page 11

The E5805A USB/RS232 Interface Utility Program

For all Windows Operating Systems

The E5805A USB/RS232 Interface configuration utility program, which is available from the Start menu, allows you to manage the serial ports of your 4 Port Interface product.

Agilent Technologies E5805A — The E5805A USB/RS232 Interface Utility Program diagram (page 11)
Fig. 4 · The E5805A USB/RS232 Interface Utility Program
Page 12 of the Agilent Technologies E5805A user manual — The E5805A USB/RS232 Interface Utility Program
Page 12 · click to enlarge
Page 12

The General tab in this utility allows you to do the following:

Agilent Technologies E5805A — The E5805A USB/RS232 Interface Utility Program diagram (page 12)
Fig. 5 · The E5805A USB/RS232 Interface Utility Program

1 Information - Check the manufacturing information related to your device.

2 Configure - Reassign your device’s physical port to any available Windows COM port number from 1 to 255 and give your device a user- friendly Device Name. This capability is particularly helpful if you have more than one device.

Page 13 of the Agilent Technologies E5805A user manual — The E5805A USB/RS232 Interface Utility Program
Page 13 · click to enlarge
Page 13
Agilent Technologies E5805A — The E5805A USB/RS232 Interface Utility Program diagram (page 13)
Fig. 6 · The E5805A USB/RS232 Interface Utility Program

Port Flags - Configure performance options and special functionality on a per- port basis.

  • Remap Baud : Setting the baud rate to 1200 baud will result in 230400 baud
  • Fast Reads :

This flag is used when an application requires a read to complete immediately. In the read immediate case, the E5805A USB/RS232 Interface driver sends a request to the device asking for any buffered data to be sent. This buffered data will be included when the read completes. If this flag is set, the driver does not query the device for additional data.

  • Fast Writes : When an application sends a write to the driver, by default the E5805A USB/RS232 Interface driver waits until all data has been transmitted out of the device before completing the write. When the Fast Writes flag is set, the write is completed even if data is still buffered in the driver and the device.
  • Ignore Tx Purge : The IOCTL_SERIAL_PURGE request cancels the specified requests and deletes data from the specified buffers. The purge request can be used to cancel all read requests, all write requests, and to delete all data from the read and write buffers.
Page 14 of the Agilent Technologies E5805A user manual — The E5805A USB/RS232 Interface Utility Program
Page 14 · click to enlarge
Page 14

When the Ignore Tx Purge flag is set the SERIAL_PURGE_TXCLEAR command is ignored. The function does not purge the write buffer.

  • Disable Plug & Play : (Windows 2k/XP only)

Do not let the serial port enumerator detect devices plugged into the 4 Port Interface.

  • Timer Logic : (Windows 98SE only)

If the application uses PortSetReadCallBack(), the notification routine is only called when the number of bytes in the receive buffer is greater then the RX trigger. The Microsoft serial VxD also implements a timer that triggers and calls the notification routine if some amount of data is available in the RX buffer, but no new data has been received for ~200ms (receiver is no longer active).

We do not enable this behavior by default because of the nature of E5805A USB/RS232 Interface’s buffering. However, if you set the flag, the read is completed when ~200 ms of no activity is detected.

Here is a comment from the code:

If the receiver is active, then do not complete this read. The problem is that the device buffers the RX bytes and we poll the driver. If we do not receive any bytes in 200ms we may report an erroneous event even if there are available bytes in the device or driver.

Test Ports - Performs a confidence test on the internal workings of the serial ports..

Page 15 of the Agilent Technologies E5805A user manual — The E5805A USB/RS232 Interface Utility Program
Page 15 · click to enlarge
Page 15
Agilent Technologies E5805A — The E5805A USB/RS232 Interface Utility Program diagram (page 15)
Fig. 7 · The E5805A USB/RS232 Interface Utility Program

The Version tab allows you to check the file information related to the software. There is no graphic of this tab.

Page 16 of the Agilent Technologies E5805A user manual — The E5805A USB/RS232 Interface Utility Program
Page 16 · click to enlarge
Page 16
Agilent Technologies E5805A — The E5805A USB/RS232 Interface Utility Program diagram (page 16)
Fig. 8 · The E5805A USB/RS232 Interface Utility Program

The Advanced tab allows you to do the following:

  • Uninstall the drivers.
  • Enable Event Logging – Place event messages in the system event log.
  • Configure how COM ports are assigned.

The driver supports COM port number assignment in two ways:

1 Assign COM ports based on the converter serial number.

This is the default setting. In this mode, the driver uses the serial number of each converter to uniquely identify it, and the COM port assignments for a given converter are based on its serial number. No matter which physical USB port a converter is plugged into, it maintains its assigned COM port numbers.

2 Assign COM ports based on physical USB port.

Page 17 of the Agilent Technologies E5805A user manual — The E5805A USB/RS232 Interface Utility Program
Page 17 · click to enlarge
Page 17

In this mode, the driver identifies a converter based on the physical USB port where it is connected. This effectively assigns COM port numbers to physical USB ports. No matter which converter is plugged into a given USB port, it uses the COM port numbers assigned to that USB port. This permits a converter to be replaced with a new unit, and, although the new unit has a different serial number, it receives the same COM port assignments as the old unit because they were both plugged into the same USB port.

When using this mode, converters are not identified by their serial number, but by a 2- 7 digit number that identifies the USB port it is plugged into.

After changing this setting, you need to reboot before the change takes effect.

Page 18 of the Agilent Technologies E5805A user manual — Understanding the E5805A and USB Hubs
Page 18 · click to enlarge
Page 18

Understanding the E5805A and USB Hubs

Hubs, critical components in the USB architecture, are wiring concentrators that enable the attachment of multiple devices, thus converting a single attachment point into multiple attachment points. USB architecture allows a cascaded multiple hub configuration with certain power limitations (explained later in this section). See Figure 1.

Agilent Technologies E5805A — Understanding the E5805A and USB Hubs diagram (page 18)
Fig. 9 · Understanding the E5805A and USB Hubs

Figure 1 Hub Architecture

Each hub has an upstream port, connecting to the host, and multiple downstream ports, connecting to downstream devices, possibly including other hubs. A hub can detect attachment and detachment of downstream devices and enable and monitor the distribution of the power to downstream devices via their integral hardware and the operating system.

Each USB device reports its power requirements to the operating system, which then enables and disables the device as a function of its power requirements and the amount of available power. High powered devices typically need to be connected to a self- powered hub that obtains power from its external power supply and provides up to 500 mA for each downstream port. Only low powered devices, such as a mouse,

Page 19 of the Agilent Technologies E5805A user manual — Understanding the E5805A and USB Hubs
Page 19 · click to enlarge
Page 19

can be connected to a bus- powered hub, which obtains power from its upstream host and provides up to 100 mA for each downstream port.

Due to the limited available power for bus- powered hubs, cascading two bus- powered hubs is an illegal topology, and devices connected to the second hub will not function. USB specifications limit the connection of a bus- powered hub to a self- powered hub or host only.

According to the USB Specification, the maximum limit of hubs cascaded in series cannot exceed five. In other words, you may have a maximum of five hubs between any device and the host. This does not mean that the maximum number of hubs in a system is five. Indeed, up to seven hubs can be connected parallel at any given level. You must tally both external and embedded hubs when counting downstream hubs.

Page 20 of the Agilent Technologies E5805A user manual — Support
Page 20 · click to enlarge
Page 20

Support

All support can be reached by contacting a call center. For your nearest call center, go to http://www.agilent.com/find/assist

Page 21 of the Agilent Technologies E5805A user manual — A
Page 21 · click to enlarge
Page 21

A

E5805A Specifications

Page 22 of the Agilent Technologies E5805A user manual — 18 Appendix A
Page 22 · click to enlarge
Page 22

E5805A Specifications

This appendix lists E5805A Agilent USB/RS232 Interface Technical Specifications and Supplementary Information.

18 Appendix A

Page 23 of the Agilent Technologies E5805A user manual — Appendix A 19
Page 23 · click to enlarge
Page 23

E5805A Specifications Technical Specifications

Technical Specifications

Windows 98 Second Edition /Me/2000/XP Professional (Windows Vista is not supported). A USB port (OS may require more resources)

Supported Standards USB 1.0, 1.1 compatible; backwards compatible for USB 2.0

Power External power supply not required (USB powered) Maximum Power - 2.5W

Device Status LEDs for system and device status

Baud Rate 230 Kbps per serial port simultaneously

Acquisition Automatic port acquisition

Reboots COM port assignments maintained across reboots

Flow Control Full hardware and software flow control

LEDs Tri-state LED displays device status and COM port activity

Memory and IRQs No additional IRQ or memory address requirements

Length, Width, and Height 11.05 cm (L) x 18.29 cm (W) x 2.61 cm (H)

Operating Environment 32o F to 131o F (0oC to 55oC)

Humidity 0% to 95% (Non-condensing)

Appendix A 19

Show 9 more labels / short text on this page
General Requirements · Minimum System Requirements · General Characteristics · Certification USB-IF™ certified · Configuration Plug-and-Play · Hot-swappable · Dimensions · Weight 311 grams · Environmental Specifications
Page 24 of the Agilent Technologies E5805A user manual — 20 Appendix A
Page 24 · click to enlarge
Page 24

E5805A Specifications Technical Specifications

20 Appendix A

Page 25 of the Agilent Technologies E5805A user manual — Conforms with the following product standards:
Page 25 · click to enlarge
Page 25

DECLARATION OF CONFORMITY

According to ISO/IEC Guide 22 and CEN/CENELEC EN 45014

Manufacturer’s NameAgilent Technologies, Incorporated
Manufacturer’s Address815 – 14 th St. SW Loveland, Colorado 80537 USA

Declares, that the product

Product NameUSB/4-port RS232 Interface
Model NumberE5805A

Product Options: This declaration covers all options of the above product(s).

Conforms with the following European Directives:

The product herewith complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC (including 93/68/EEC) and carries the CE Marking accordingly. This product is intended for use with ISM equipment.

Conforms with the following product standards:

EMC Standard

Limit

CISPR 22:1997 / EN 55022:1998 CISPR 24:1997 / EN 55024:1998 IEC 61000-4-2:1995+A1:1998 / EN 61000-4-2:1995 IEC 61000-4-3:1995 / EN 61000-4-3:1995 IEC 61000-4-4:1995 / EN 61000-4-4:1995 IEC 61000-4-5:1995 / EN 61000-4-5:1995 IEC 61000-4-6:1996 / EN 61000-4-6:1996 IEC 61000-4-8:1993 / EN 61000-4-8:1993 IEC 61000-4-11:1994 / EN 61000-4-11:1994

4 kV CD, 8 kV AD 3 V/m, 80-1000 MHz 0.5 kV signal lines, 1 kV power lines 2 kV CM, 1 kV DM 3 V, 0.15-80 MHz, Mod 1 kHz, 80% 1 A/m, 50 Hz Dips: 95% 10 ms; 30% 500 ms; Interrupt > 95% 5 s

CanadaICES/NMB-003:1998 [2]
Australia/New ZealandAS/NZS 3548

Safety IEC 60950:1991 +A1, A2, A3, A4 / EN 60950:1992 + A1, A2, A3, A4 USA: UL 1950, 3rd edition Canada: CSA C22.2 No. 950

Class B

Page 26 of the Agilent Technologies E5805A user manual — Supplemental Information:
Page 26 · click to enlarge
Page 26

Supplemental Information:

[1] This product was tested in a typical configuration with Agilent Technologies test systems.

[2] This Class B digital apparatus complies with Canadian ICES-003. [3] Cet appareil numerique de la classe B est conforme a la norme NMB-003 du Canada.

Agilent Technologies E5805A — Supplemental Information: diagram (page 26)
Fig. 10 · Supplemental Information:

Product Regulations Program Manager

For further information, please contact your local Agilent Technologies sales office, agent or distributor.

27 September 2004 · Date Ray Corson

Page 27 of the Agilent Technologies E5805A user manual — サポート 38
Page 27 · click to enlarge
Page 27

E5805A USB/RS232 インタフェース 1

1 Agilent USB/RS232 インタフェース

インストール ガイド

E5805A USB/RS232 インタフェース 24 E5805A USB/RS232 インタフェース ドライバのインストール 25

システム ステータス ランプの説明 28 E5805A USB/RS232 インタフェースのユーティリティ・プログラム 29 E5805A と USB ハブについて 36

サポート 38

E5805A USB/RS232 インタフェース 23

Ask about the Agilent Technologies E5805A

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Agilent Technologies E5805A

Be the first to ask — other owners or our team will answer.

Original document

Agilent Technologies E5805A manual PDF

47 pages·532 KB·Network Router·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…