Instruction/ maintenance manual of the product BCDV48N Continental
Go to page of 28
W415-0327 / B / 12.07.07 1 W415-0327 / B / 12.07.07 $10.00.
W415-0327 / B / 12.07.07 2 Framing Minimum Mantel and Enclosure Clearances Nailing T ab Installation 19-20 FINISHING Log Placement Charcoal Embers V ermiculite Glowing Embers Logo Placement Louvre Ins.
W415-0327 / B / 12.07.07 3 CONDITIONS AND LIMIT A TIONS WOLF STEEL LTD. warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or l egal entity (registered customer) whose name appears on the warranty registration card filed with WOLF STEEL Ltd.
W415-0327 / B / 12.07.07 4 THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. In absence of local codes, install the BCDV48 to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes.
W415-0327 / B / 12.07.07 5 FIGURE 1 INST ALLA TION O VERVIEW FIGURE 2.
W415-0327 / B / 12.07.07 6 Use only Wolf Steel, Simpson Dura-V ent, Selkirk Direct T emp or American Metal Amerivent venting components.Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal locations for either system are set out in this manual and must be adhered to.
W415-0327 / B / 12.07.07 7 MINIMUM AIR TERMINAL L OCA TION CLEARANCES FIGURE 3.
W415-0327 / B / 12.07.07 8 FIGURE 5 SPECIAL VENT INST ALLA TIONS NO TE: When ter minating v er tically , the restrictor plate W500- 0205 must be installed. R efer to Restricting V er tical V ents. PERISCOPE TERMINA TION TYPICAL MINIMUM AND MAXIMUM VENT LENGTHS FIGURES 4 a-b Use only GD401 periscope kit to locate the air termination above grade.
W415-0327 / B / 12.07.07 9 VER TICAL TERMINA TION HORIZONT AL TERMINA TION vertical rise is equal to or greater than the horizontal run horizontal run + v erti- cal rise to maximum of 40 feet vertical.
W415-0327 / B / 12.07.07 10 ELBOW VENT LENGTH V ALUES DEFINITIONS HORIZONT AL TERMINA TION REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFF- SETS IN FEET (H T ) FIGURE 6.
W415-0327 / B / 12.07.07 11 V 1 HORIZONT AL TERMINA TION See graph to determine the required vertical rise V T for the required hori- zontal run H T . For vent confi gurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.
W415-0327 / B / 12.07.07 12 VERTICAL TERMIN A TION Example 3: V 1 = 5 ft V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 = 3 ft H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03 (one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.
W415-0327 / B / 12.07.07 13 H 1 VERTICAL TERMIN A TION For vent confi gurations requiring more than one 45º and one 90° elbow , the following formulas apply: F or mula 1: H T < 3V T F or mula 2:.
W415-0327 / B / 12.07.07 14 FIGURE 16 This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Continental® dealer .
W415-0327 / B / 12.07.07 15 FIGURE 25 4. Insert the vent pipe assembly through the fi restop maintaining the required clearance to combustibles. Holding the air terminal (lettering in an upright, readable position), secure to the exterior wall and make weather tight by sealing with caulking (not sup- plied).
W415-0327 / B / 12.07.07 16 FIGURE 31 RESTRICTOR PLA TE TOP OF THE FIREBOX FLUE COLLAR The vent system must be supported approximately every 3 feet for both vertical and horizontal runs.
W415-0327 / B / 12.07.07 17 Proceed once the vent installation is complete. NOTE: All gas connections must be contained within the fi replace when complete. 1. Move the fi replace into position and secure to the fl oor through the 1/4" holes located at either side of the base.
W415-0327 / B / 12.07.07 18 MINIMUM MANTEL AND ENCLOSURE CLEARANCES Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clearance needed. Curtains, above the fi replace, must not be positioned lower than the 2" distance re- quired for the 2" combustible mantel.
W415-0327 / B / 12.07.07 19 NAILING TA B FIGURE 39 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws supplied. Secure through the centre of the top and bottom slots in the nailing tab and then through the existing holes in the corner posts.
W415-0327 / B / 12.07.07 20 B A Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner . Fine dust found in the bottom of the bag should not be used. Sprinkle vermiculite around the charcoal embers. Note: Both char coal embers and vermiculite ar e not to be placed on the burner .
W415-0327 / B / 12.07.07 21 FIGURE 50 FIGURE 45 INST ALLA TION TO BE DONE BY A QUALIFIED INST ALLER and must be electrically connected and grounded in accord- ance with local codes.
W415-0327 / B / 12.07.07 22 When lit for the fi rst time, the fi replace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again.
W415-0327 / B / 12.07.07 23 VENTURI CO VER Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow . Air shutters have been factory set open according to the chart below: These settings are for the maximum horizontal vent run.
W415-0327 / B / 12.07.07 24 1 W357-0001 PIEZO IGNITER 2 W680-0004 THERMOPILE 3 W680-0005 THERMOCOUPLE ** 4 W010-0796 NA TURAL GAS PILOT ASSEMBL Y 4 W010-0797 PROP ANE GAS PILOT ASSEMBL Y 5* W573-0008 .
W415-0327 / B / 12.07.07 25.
W415-0327 / B / 12.07.07 26 TR OUBLE SHOO TING GUIDE Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button igniter . - check if the push button igniter needs tightening. - replace the wire if the wire insulation is broken or frayed.
W415-0327 / B / 12.07.07 27 SYMPT OM PROBLEM TEST SOLUTION Flames are consist- ently too large or too small. Carboning oc- curs. - check pressure readings: Inlet pressure can be checked by turning screw (A) counter-clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point.
W415-0327 / B / 12.07.07 28 NO TES.
An important point after buying a device Continental BCDV48N (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Continental BCDV48N yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Continental BCDV48N - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Continental BCDV48N you will learn all the available features of the product, as well as information on its operation. The information that you get Continental BCDV48N will certainly help you make a decision on the purchase.
If you already are a holder of Continental BCDV48N, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Continental BCDV48N.
However, one of the most important roles played by the user manual is to help in solving problems with Continental BCDV48N. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Continental BCDV48N along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center