G ETTING S TARTED G UIDE Cisco Aironet 1600 Series Access Points December , 2012 Revised: April 1 6, 2013 1 About this Guide 2 Introduction to the Access Point 3 Safety Instructi ons 4 Unpacking 5 Con.
2 1 About this Guide This Guide provides in structions on how to inst all and configure your Cisco Aironet 1600 Series Access Point. The 1600 Series Ac cess Point is referred to as the 160 0 series or the acce ss point in this document. 2 Introduction to the Access Point The 1600 series offers dual-band ra dios (2.
3 • 802.11af/at – CDP (Cisco Discovery Protocol) • 2.4 GHz and 5 GHz 802.11n radios with the following features: – 3TX x 3RX – 2 spatial streams, 300 Mbps PHY rate – DPD (Digital Pre-Distortion) technology – Radio hardware is capable of explicit comp ressed beamforming (ECBF) per 802.
4 War n in g Do not operate your wirel ess network device near u nshielded blasting caps or in an explosive environment unless the device has been mod ified to be especially qualified for such use. Statement 245B War n in g In order to comply wi th FCC radio frequency (RF) exposure limits, an tennas should be located at a minimum of 7.
5 Step 3 V erify that you have rece ived the items listed below . If any item is missing or damaged, contact your Cisco representative or reseller for instructions.
6 Internal Antennas The 1602I model access p oints are configured with up to three dual-band inverted-F antennas and two 2.4-GHz/5-GHz dual-band radios. Each antenna covers both the 2.4 GHz and the 5 GHz bands with a single feed line. The basic features are as follows: • Dual-band inverted-F antenna for use in both th e 2.
7 Figur e 1 Access P oint Por ts and Connections (t op) 1 Antenna connector A 3 Antenna connector C 2 Antenna connector B.
8 Figur e 2 Access P oint LED Indicator (top) The ports and connections on the bottom of the access point are shown in Figure 3 . Figur e 3 Access P oint Por ts and Connections (bot tom) 1 LED indicat.
9 7 Configuring the Access Point This section describes how to connect the access point to a wireless LAN controller . Because the configuration process takes plac e on the controller , see the Cisco Wireless LAN Controller Configuration Guide for additional information.
10 Note CAPW A P support is provided in controller so ftware release 5.2 or later . However , your controller mu st be runn ing release 7.4.x. x or later to su pport 1600 series access points. Note Y ou cannot edit or query any ac cess poin t using the controller C LI if the name of the access point contains a space.
11 Preparing the Access Point Before you mount and deploy your access point, we recommend that you perform a site survey (or use the site planning tool) to determine the be st location to install your access point. Y ou should have the follow ing information about y our wireless network available: • Access point locations.
12 Performing a Pre-Instal lation Configuration The following procedures ensure th at your access point installati on and initial op eration go as expected. A pre-installation configuration is also known as priming the access point . This procedure is optional.
13 Step 1 Make sure that the Cisco wireless LAN controller DS port is connected to the network. Use the CLI, web-browser interface, or Cisco Prime Infrastructure procedures as described in the appropriate Cisco wireless LAN controller guide.
14 Note If the access point remains in this mode for more than five minutes, the access point is unable to find the Master Cisc o wireless LAN contro ller. Check the connection betwee n the access point and the Cisco wirele ss LAN controller and be sure that they are on the same subnet.
15 8 Mounting the Access Point Cisco Aironet 1600 series access points can be mo unted in severa l configurations, including on a suspended ceiling, on a hard ceiling or wall , on an electrical or n etwork box, and above a su spended ceiling. Click this URL to browse to comp lete access point mounting instructions: http://www.
16 10 Troubleshooting If you experience difficulty getti ng your access point installed and running, lo ok for a solution to your problem in this guide or in additional access po int documentation. These, and other documents, are available on Cisco.com.
17 Figur e 5 Access P oint LED Location The access point status LED indicates va rious conditions and are described in Table 1 . 1 Status LED T a ble 1 LED Status Indicati ons Message Ty p e Status LE.
18 Troubleshooting the Ac cess Point Join Process Access points can fail to join a controller for many reasons: a R ADIUS auth orization is pending; self-signed certificat es are not enabled on the cont roller; the access point’ s and controller’ s regulatory domains don’ t match, a nd so on.
19 Controller software enables you to configure the a cce ss points to send all CAPW AP-related errors to a syslog server . Y ou do not need to enable any de bug command s on the controller because all of the CAPW A P error messages ca n be viewed from the syslog server itself.
20 Y ou can configure the syslog server for access points and view th e access point join information only from the controller CLI. A detailed explanation of th e join process is on Cisco.com at the following URL: http://www.Cisco.com/en/US/products/ps6366/products_tech_note09 186a00808f8599.
21 This device complies with Part 15 rules. Operation is subject to the followin g two conditions: 1. This device may not cause harmful interferenc e, and 2. This device must accept any interference received, incl uding interference that may cause undesired operation.
22 VCCI Statement for Japan War n in g This is a Class B product based on the standard of the V oluntary Control Council for Interf erence from Information T echnology Equipment (VCCI). If thi s is used near a radio or television receiver in a domestic environment, it may cause radio interference.
23 Guidelines for Operating Cisco Aironet Access Points in Japan This section provides guidelines for avoiding interf erence when operating Cisc o Aironet access points in Japan.
24 Statement 371—Power Cable and AC Adapter English Translation When installing th e product, please use the provided or designated connection cables/power cables/AC adaptors.
25 This device complies with Class B Limits of Industry Canada. Operatio n is subject to the follo wing two conditions: 1. This device may not cause harmful interferenc e, and 2. This device must accept any interference received, incl uding interference that may cause undesired operation.
26 Declaration of Conformity with regard to the R&TTE Directive 1999/5/EC & Medical Directive 93/42/EEC.
27 The following standards were applied: EMC—EN 301.489-1 v1.8.1; EN 301.489-17 v2.1.1 Health & Safety—EN60950-1: 2005; EN 50385: 2002 Radio—EN 300 328 v 1.7.1; EN 301.893 v 1.5.1 The conformity assessment procedure ref e rred to in Article 10.
28 This device also conforms to the EMC requirem ents of the Medical Devices Directi ve 93/42/EEC. Note This equipment is intended to be used in a ll EU and EF T A co untries. Outdoor use may be restricted to certain frequencie s and/or may require a license fo r operation.
29 As such the systems are desi gned to be operated as to avoid contact with the antennas by the end user . It is recommended to set the system in a location where the antennas can remain at least a m.
30 This Device Meets the In dustry Canada Guidelines for Exposure to Radio Waves The 1600 series device includes a radio transmi tter an d receiver . It is designed not to exceed the limits for exposure to radio waves (radio frequency electrom agnetic fields) as referenced in Heal th Canada Safety Code 6.
31 • United Kingdom, National Radiological Protection Board at this URL: www.nrpb.org.uk • Cellular T elecommunications Association at this U RL: www.
32 English Translation Administrative Rules for Low- power Radio-Frequency Devices Article 12 For those low-power radio-frequenc y devices that have alr e ady recei ved a type -approval , compani es, business units or users should not change its freque ncies, increase its power or change its original features and functions.
33 English Translation Low-power Radio-frequency Devices T echn ical Specifications Operation of Cisco Aironet Access Points in Brazil This section contains special information for oper ation of Cisco Aironet access points in Brazil.
Figur e 6 Brazil Regulat ory Inf ormation Portuguese Translation Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo, e nã o po de causar interferência a sistemas operando em caráter primário.
35 12 Access Point Specifications Table 2 lists the technical speci fications for 1600 series acc ess points. T able 2 A ccess Point Specifications Category Specification Dimensions (LxWxD) 8.68 x 8.68 x 1.84 in. (22.04 x 22.0 4 x 4.67 cm) W eight 1.9 lbs (0.
36 13 Obtaining Documentation and Submitting a Service Request For information on obtaining documentation, submitti ng a service request, and gathering additional information, see the monthly What’ s New in Cisco Product Documentation , which also lists all new and revised Cisco technical documentation, at: http://www .
37.
Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: www.cisco .com/go/trademarks . Third-party trad emarks mentioned are the p roperty of their respec tive owners.
An important point after buying a device Cisco Systems 1602I (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Cisco Systems 1602I yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Cisco Systems 1602I - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Cisco Systems 1602I you will learn all the available features of the product, as well as information on its operation. The information that you get Cisco Systems 1602I will certainly help you make a decision on the purchase.
If you already are a holder of Cisco Systems 1602I, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Cisco Systems 1602I.
However, one of the most important roles played by the user manual is to help in solving problems with Cisco Systems 1602I. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Cisco Systems 1602I along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center