Page 1 of the Chicago Electric Wireless Remote Switch (66508) user manual — 50 FT. DRAIN CLEANER WITH POWER FEED
Page 1 · click to enlarge
Page 1

50 FT. DRAIN CLEANER WITH POWER FEED

ASSEMBLY AND OPERATING INSTRUCTIONS

Chicago Electric Wireless Remote Switch (66508) — 50 FT. DRAIN CLEANER WITH POWER FEED diagram (page 1)
Fig. 1
Visit our website athttp://www.harborfreight.com

Read this material before using this product.

Failure to do so can result in serious injury. Save this manual.

Copyright© 2008 by Harbor Freight Tools®. All rights reserved. No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product described herein. Tools required for assembly and service may not be included.

For technical questions or replacement parts, please call 1-800-444-3353. Revised Manual 09b, 09k

Page 2 of the Chicago Electric Wireless Remote Switch (66508) user manual — Work Area
Page 2 · click to enlarge
Page 2

Specifications

the presence of flammable liquids, gases, or dust. Power tools create sparks which may ignite the dust or fumes.

Electric Motor1/3 HP 1785 RPM Power Cord#16 AWG X 3C, 6’4” long Power Input120 V~ / 60 Hz / 4.7 A (running) Cable TypeSpring Steel with Coupler End 50’ L x ½” Cable Diameter (0.123” Wire Diameter) Pipe CompatibilityFor use with pipes having 2” to 4” I.D.

Keep bystanders, children, and visi 3. tors away while operating a power tool. Distractions can cause you to lose control. Protect others in the work area from debris such as chips and sparks. Provide barriers or shields as needed.

Electrical Safety

Avoid body contact with grounded 1. surfaces such as pipes, radiators, ranges, and refrigerators. There is an increased risk of electric shock if your body is grounded.

Save This Manual

You will need the manual for the safety warnings and precautions, assembly instruc tions, operating and maintenance procedures, parts list and diagram. Keep your invoice with this manual. Write the invoice number on the inside of the front cover. Keep the manual and invoice in a safe and dry place for future reference.

Do not expose power tools to rain 2. or wet conditions. Water entering a power tool will increase the risk of electric shock.

Grounded tools must be plugged 3. into an outlet properly installed and grounded in accordance with all codes and ordinances. Never remove the grounding prong or modify the plug in any way. Do not use any adapter plugs. Check with a qualified electri cian if you are in doubt as to whether the outlet is properly grounded. If the tools should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user.

General Safety Rules

WARNING!

READ AND UNDERSTAND ALL

INSTRUCTIONS Failure to follow all instructions listed

below may result in electric shock,

fire, and/or serious injury. SAVE THESE INSTRUCTIONS

Double insulated tools are equipped 4. with a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install a polarized outlet. Do not change the plug in any way. Double insulation

Work Area

Keep your work area clean and well 1. lit. Cluttered benches and dark areas invite accidents.

Do not operate power tools in ex 2. plosive atmospheres, such as in

REV 09b, 09k

Page 3 of the Chicago Electric Wireless Remote Switch (66508) user manual — Personal Safety
Page 3 · click to enlarge
Page 3

Do not overreach. 5. Keep proper foot ing and balance at all times. Proper footing and balance enables better control of the power tool in unexpected situations.

eliminates the need for the three wire grounded power cord and grounded power supply system.

Do not abuse the Power Cord. 5. Never use the Power Cord to carry the tools or pull the Plug from an outlet. Keep the Power Cord away from heat, oil, sharp edges, or moving parts. Replace damaged Power Cords immediately. Damaged Power Cords increase the risk of electric shock.

Use safety equipment. 6. Always wear eye protection. Dust mask, nonskid safety shoes, hard hat, or hearing pro tection must be used for appropriate conditions.

Tool Use and Care

When operating a power tool out 6. side, use an outdoor extension cord marked “W-A” or “W”. These exten sion cords are rated for outdoor use, and reduce the risk of electric shock.

Do not force the tool. 1. Use the correct tool for your application. The correct tool will do the job better and safer at the rate for which it is designed.

Personal Safety

Do not use the power tool if the 2. Power Switch does not turn it on or off. Any tool that cannot be controlled with the Power Switch is dangerous and must be replaced.

Stay alert. 1. Watch what you are doing, and use common sense when operat ing a power tool. Do not use a power tool while tired or under the influence of drugs, alcohol, or medication. A moment of inattention while operating power tools may result in serious per sonal injury.

Disconnect the Power Cord Plug 3. from the power source before mak ing any adjustments, changing ac cessories, or storing the tool. Such preventive safety measures reduce the risk of starting the tool accidentally.

Dress properly. 2. Do not wear loose clothing or jewelry. Contain long hair. Keep your hair, clothing, and gloves away from moving parts. Loose clothes, jewelry, or long hair can be caught in moving parts.

Store idle tools out of reach of chil 4. dren and other untrained persons. Tools are dangerous in the hands of untrained users.

Check for misalignment or binding 5. of moving parts, breakage of parts, and any other condition that may af fect the tool’s operation. If damaged, have the tool serviced before using. Many accidents are caused by poorly maintained tools.

Avoid accidental starting. 3. Be sure the Power Switch is off before plugging in. Carrying power tools with your fin ger on the Power Switch, or plugging in power tools with the Power Switch on, invites accidents.

Remove adjusting keys or wrenches 4. before turning the power tool on. A wrench or a key that is left attached to a rotating part of the power tool may result in personal injury.

Use only accessories that are rec 6. ommended by the manufacturer for your model. Accessories that may be suitable for one tool may become haz ardous when used on another tool.

Page 4 of the Chicago Electric Wireless Remote Switch (66508) user manual — for This Product
Page 4 · click to enlarge
Page 4

Service

area free of obstructions, grease, oil, trash, and other debris. Do not use a power tool in areas near flammable chemicals, dusts, and vapors

Tool service must be performed 7. only by qualified repair personnel. Service or maintenance performed by unqualified personnel could result in a risk of injury.

Always unplug the Drain Cleaner 6. from its electrical outlet before performing any inspection, mainte nance, or cleaning procedures.

When servicing a tool, use only 8. identical replacement parts. Follow instructions in the “Inspection, Mainte nance, And Cleaning” section of this manual. Use of unauthorized parts or failure to follow maintenance instruc tions may create a risk of electric shock or injury.

Never leave the Drain Cleaner unat 7. tended while running. Turn power off if you have to leave the Drain Cleaner.

Before each use, check all nuts, 8. bolts, and screws for tightness. Vibration during operation may cause these to loosen.

Specific Safety Rules

Avoid electrical shock. 9. Do not op erate the Drain Cleaner if sitting in standing water, and if the operator is in standing water. Keep extension cord off the ground and away from water. Water increases the risk of electric shock.

for This Product

Maintain labels and nameplates on 1. the Drain Cleaner. These carry im portant information. If unreadable or missing, contact Harbor Freight Tools for a replacement.

Always connect the Line Cord to 10. a Ground Fault Circuit Interrupter (GFCI) protected electrical outlet.

Always wear ANSI-approved safety 2. impact eye goggles and heavy, leather work gloves when using the Drain Cleaner. Never grasp a rotating cable with a rag or cloth glove. Using personal safety devices reduce the risk for injury. Safety impact eye goggles and heavy work gloves are available from Harbor Freight Tools.

Install this product on a proper sur 11. face. Locate on a flat, level, and solid surface that is capable of supporting the weight of the Drain Cleaner.

Never operate the Drain Cleaner with 12. the belt guard removed. Fingers can get caught between the drive belt and pulley.

Avoid unintentional starting. 3. Make sure you are prepared to begin work before turning on the Drain Cleaner.

Do not overstress cable. 13. Keep gloved hand on the cable for control when ma chine is running. In the course of drain cleaning, if the cable encounters an obstruction, it may stress the cable and cause the cable to twist, kink, or break. This may result in serious injury, and damage the equipment or pipes.

Do not force the Drain Cleaner. 4. This tool will do the work better and safer at the speed and capacity for which it was designed.

Maintain a safe working environ 5. ment. Keep the work area well lit. Make sure there is adequate surround ing workspace. Always keep the work

Position Drain Cleaner within two 14. feet of drain opening. Greater dis

Page 5 of the Chicago Electric Wireless Remote Switch (66508) user manual — Grounded Tools: Tools with Three
Page 5 · click to enlarge
Page 5

tances can result in the cable twisting or kinking.

Grounding

To prevent electric shock and death from incorrect grounding wire connection: Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the power cord or plug is damaged. If damaged, have it repaired by a service facility before use. If the plug will not fit the outlet, have a proper outlet installed by a qualified electrician.

For safest operation, the Drain 15. Cleaner should be run only by the operator controlling the Foot Pedal and Cable.

Reversing the Motor direction should 16. only be done when pulling the Cable out of the pipe, or off an obstruction. Trying to push the Cable down the pipe while in reverse operation can result in Cable damage. Make sure Drum has stopped turning before changing the Motor Direction Switch (5).

Keep hands away from the rotating 17. Drum (38a) and Feed Pipe (42a). Do not reach into Drum unless the Drain Clean power cord is unplugged.

Avoid contact to eyes and skin of 18. any drain cleaners that may have been used to unclog the drain pre vious to using the Drain Cleaner. These chemicals can burn the eyes and skin. They may also damage the Cable.

Grounded Tools: Tools with Three

Prong Plugs

Be aware of possible damage to 19. drain lines that may result from the discovery of roots and other ob stacles.

  • 20. WARNING! People with pacemak ers should consult their physician(s) before using this product. Electro magnetic fields in close proximity to a heart pacemaker could cause interfer ence to or failure of the pacemaker. In addition, people with pacemakers should adhere to the following:
  • Avoid operating power tools alone.
  • Properly maintain and inspect all tools before use to avoid electrical shock.

Tools marked with “Grounding Re 1. quired” have a three wire cord and three prong grounding plug. The plug must be connected to a properly grounded outlet. If the tool should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user, reducing the risk of electric shock. (See 3-Prong Plug and Outlet.)

Page 6 of the Chicago Electric Wireless Remote Switch (66508) user manual — Extension Cords
Page 6 · click to enlarge
Page 6

The grounding prong in the plug is con 2. nected through the green wire inside the cord to the grounding system in the tool. The green wire in the cord must be the only wire connected to the tool’s grounding system and must never be attached to an electrically “live” termi nal. (See 3-Prong Plug and Outlet.)

Ground Fault Circuit Interrupter

(GFCI)

A Ground Fault Circuit Interrupter (GFCI) is manufactured within the Power Cord (15), about midway, due to the risk of electrical shock when operating the Drain Cleaner, and its proximity to water and ground. The GFCI provides additional protection from the risk of electrical shock.

The tool must be plugged into an ap 3. propriate outlet, properly installed and grounded in accordance with all codes and ordinances. The plug and outlet should look like those in the preceding illustration. (See 3-Prong Plug and Outlet.)

Chicago Electric Wireless Remote Switch (66508) — Ground Fault Circuit Interrupter diagram (page 6)
Fig. 2 · Ground Fault Circuit Interrupter

Make sure that the Motor Direction 1. Switch is in the Off position before plug ging in the Drain Cleaner.

Double Insulated Tools: Tools with

Two Prong Plugs

Plug the GFCI Power Plug into a 2. grounded, 120 VAC electrical outlet.

Press the TEST button, then press the 3. RESET button. The GFCI indicator should show Red in the window.

If the indicator is not red, try plugging the Power Cord into a different electri cal outlet and repeat the steps. If the same results occur, have the Power Cord inspected by a licensed electri cian. Repair or replacement must be completed by a licensed electrician.

Tools marked “Double Insulated” do 4. not require grounding. They have a special double insulation system which satisfies OSHA requirements and com plies with the applicable standards of Underwriters Laboratories, Inc., the Canadian Standard Association, and the National Electrical Code. (See Outlets for 2-Prong Plug.)

from the GFCI unit to the 3-prong plug in the electrical outlet.

Extension Cords

Grounded 1. tools require a three wire extension cord. Double Insulated tools can use either a two or three wire extension cord.

Double insulated tools may be used in 5. either of the 120 volt outlets shown in the preceding illustration. (See Outlets for 2-Prong Plug.)

As the distance from the supply outlet 2. increases, you must use a heavier gauge extension cord. Using exten sion cords with inadequately sized wire causes a serious drop in voltage,

Page 7 of the Chicago Electric Wireless Remote Switch (66508) user manual — Unpacking
Page 7 · click to enlarge
Page 7

resulting in loss of power and possible tool damage. (See Figure C, next page.)

RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS* (120/240 VOLT) NAMEPLATE AMPERES (at full load)EXTENSION CORD LENGTH 25’50’75’100’150’ 0 – 2.01818181816 2.1 – 3.41818181614 3.5 – 5.01818161412 5.1 – 7.01816141212 7.1 – 12.018141210- 12.1 – 16.0141210-- 16.1 – 20.01210--- * Based on limiting the line TABLE A voltage drop to five volts at 150% of the rated amperes.
Chicago Electric Wireless Remote Switch (66508) — Unpacking diagram (page 7)
Fig. 3 · Unpacking

The smaller the gauge number of the 3. wire, the greater the capacity of the cord. For example, a 14 gauge cord can carry a higher current than a 16 gauge cord. (See Figure C.)

When using more than one exten 4. sion cord to make up the total length, make sure each cord contains at least the minimum wire size required. (See Figure C.)

If you are using one extension cord for 5. more than one tool, add the nameplate amperes and use the sum to determine the required minimum cord size. (See Figure C.)

Double Insulated Canadian Standards Association Underwriters Laboratories, Inc. V~Volts Alternating Current AAmperes n0 xxxx/min.No Load Revolutions per Minute (RPM)

If you are using an extension cord out 6. doors, make sure it is marked with the suffix “W-A” (“W” in Canada) to indicate it is acceptable for outdoor use.

Make sure your extension cord is 7. properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified electrician before using it.

Protect your extension cords from 8. sharp objects, excessive heat, and damp or wet areas.

Unpacking

When unpacking, check to make sure that all the parts are included. Refer to the Assembly section, and the Assembly Drawing and Parts List at the end of this manual. If any parts are missing or broken, please call Harbor Freight Tools at the number on the cover of this manual as soon as possible.

Page 8 of the Chicago Electric Wireless Remote Switch (66508) user manual — Operational Components and Controls
Page 8 · click to enlarge
Page 8

Operating Instructions

The following sections describe the operational components and controls of the Drain Cleaner, as well as its operation and application.

Operational Components and Controls

The main operational components of the Drain Cleaner tool are the Motor (7), with its 1. Motor Direction Switch (5), Pneumatic Foot Pedal (14A) and the Cable Feed Unit (44a) with its direction controller.

The 2. Motor (7) is connected to the Drum (38a) using a Drive Belt (2). When turned on, the Motor turns the Drum, which causes the Spring Cable (39a) to rotate. Rotation of the Spring Cable helps it to move through bends or turns in the drain line, and also to drill through soft clogs, or entangle harder clogs for removal. (See photo below, left.)

The 3. Motor Direction Switch (5) has NORMAL, UNBIND and OFF settings. NORMAL will set the Spring Cable to rotate clockwise (viewed from machine rear), causing it to bore into or entangle any obstruction. UNBIND will cause the Spring Cable to rotate counterclockwise (viewed from machine rear), causing it to unwind from any obstruc tion. (See photo below, right.)

Chicago Electric Wireless Remote Switch (66508) — Operational Components and Controls diagram (page 8)
Fig. 4 · Operational Components and Controls
Chicago Electric Wireless Remote Switch (66508) — Operational Components and Controls diagram (page 8)
Fig. 5 · Operational Components and Controls

Motor (7), Drum (38a) and Drive Belt (2). Motor Direction Switch (5)

The Motor is controlled by a 4. Pneumatic Foot Pedal (14A). Whenever the Motor Direc tion Switch (5) is in the NORMAL or UNBIND position, stepping on the Pneumatic Foot Pedal (14A) will cause the motor to run and the Drum (38a) to turn. NOTE: The Foot Pedal is a Pneumatic Switch. (See photo on page 10, top-left.)

The rotating Drum causes the Spring Cable (39a) to rotate along its axis like a drill. The 5. Direction Lever (44-16) on the Cable Feed Unit (44a) controls the motion of the Spring Cable (39a) forward into the drain or back into the Drum (38a). The feed tension is controlled by the Star Knob (44-13). See photo on page 10, top-right. The Star Knob (44-13) must be loosened before changing the position of the Direction Lever (44-16), and then retightened after the adjustment.

Page 9 of the Chicago Electric Wireless Remote Switch (66508) user manual — Select and Attach Proper Cutting Tool
Page 9 · click to enlarge
Page 9
Chicago Electric Wireless Remote Switch (66508) — Attaching Guide Spring (48) diagram (page 9)
Fig. 6 · Attaching Guide Spring (48)
Chicago Electric Wireless Remote Switch (66508) — Attaching Guide Spring (48) diagram (page 9)
Fig. 7 · Attaching Guide Spring (48)
Pneumatic Foot Pedal (14A)Press On, release Off

Direction Lever (44-16): Pull Up: forward direction, Center: neutral; Push down: slow reverse, Fast reverse direction.

Attaching Guide Spring (48)

While following these procedures, it may be helpful to refer to the Parts List and Assembly Drawings located at the end of this manual.

Unplug the Power Cord from the electrical outlet. 1.

Pull up on the Direction Lever (44-16) to place it in the NEUTRAL position. 2.

Loosen Tension Knob (44-13) and pull out three feet of cable from the Drum (38a). 3.

Slide the Guide Spring (48) over the cable and onto the Adapter (44-3) on the end of 4. the Cable Feed Unit.

Pull out and align the Spring Loaded Pin (46) on the Guide Spring, with the hole in the 5. Adapter (44-3).

Retighten Tension Knob (44-13). 6.

Select and Attach Proper Cutting Tool

There are four Cutting Tools included with the Drain Cleaner. Select the appropriate tool for the cleaning job and attach to Cable (39a). Each is described in the table below.

Cutter ToolApplication Arrow Cutting Head (59)Starting tool for cutting and scraping Auger Bulb (60)Starting tool to remove loose objects 1-1/2” U-Cutter (61)Finishing tool for grease stoppages and scraping pipe walls 1-1/4” Side Cutter Blade (62)Starting / Finishing tool to remove loose objects and scraping pipe walls

Select the desired cutter tool and insert it into the female connector located at the 1. end of the Cable (39a). It is recommended to start with the Arrow Cutting Head (59) or Auger Bulb (60). Once the drainpipe is opened, then use the 1-1/2 U-Cutter (61) or 1-1/4” Side Cutter Blade (62) to scrape the inside wall of the drain pipe, for a more

Star Knob · (44-13)

Page 10 of the Chicago Electric Wireless Remote Switch (66508) user manual — Drain Cleaning Operation
Page 10 · click to enlarge
Page 10

thorough cleaning job. Secure the cutter tool to Cable (39a) with Phillips Screw (78) and Spring Washer (77).

Drain Cleaning Operation

Place the Drain Cleaner within two feet of the drain pipe inlet. 1.

Pull Cable (39a) from the Drum (38a) and begin feeding it into the drain pipe inlet as 2. far as it will go manually.

Verify that the Motor Direction Switch (5) is in the Off position, then plug the Power 3. Cord (15) into an electrical outlet. Press the Reset button on the GFCI.

Loosen the Star Knob (44-13) by turning it counterclockwise until it is no longer 4. pressing against the cable. See photo on page 10.

Pull the Direction Lever (44-16) up (FORWARD) to feed Cable out of the Drum. 5. Pushing the Direction Lever down (REVERSE) will retract the Cable back into the Drum. When the lever is in the middle (NEUTRAL) position, the Cable will spin in place.

Move the Motor Direction Switch (5) to the Forward position. 6. Caution: Do not force the Cable. Let the cutter do the work.

Turn (clockwise) the Star Knob (44-13), at the top of the Cable Feed Unit, until the 7. feed roller touches the Cable, then one quarter additional turn. Do not overtighten, excessive cable wear will occur. See photo on page 10.

Wearing a leather glove, place your hand on the Guide Tube or Cable, press the 8. Pneumatic Foot Pedal (14A) to start the forward Cable movement. Feed the Cable into the drain pipe inlet with a firm and even pressure against any resistance. Adjust the feeding rate to the resistance met. Do not force the Cable. Let the cutter do the work. Run hot water down the drain pipe during and after the removal of the stop page to wash away debris.

After the drain pipe has been opened, return the cable to the Drum. To do that: 10. Place the Direction Lever (44-16) in the UNBIND direction. Press the Motor Direc tion Switch (5) to the NORMAL position. Press on the Pneumatic Foot Pedal (14A) to recoil Cable. When the cutter head is near the drain pipe inlet, release Foot Pedal to stop Drum rotation. NOTE: If necessary, replace the cutter tool with the U-Cutter or Side Cutter, and reenter the drain pipe to clean the pipe walls.

Page 11 of the Chicago Electric Wireless Remote Switch (66508) user manual — Troubleshooting
Page 11 · click to enlarge
Page 11

Switch (5) in the NORMAL position, whether feeding the Cable into the drain pipe, or pulling it out. Use Reverse position only to release the Cable if it should become caught in the drain pipe line, and only for a few seconds.

When the job is complete, unplug the Power Cord from the electrical outlet and coil 12. it. Store the Drain Cleaner and cutter tools in clean and dry location.

When Cable starts to bend, twist or whip.Too much slack in Cable or cutter tool caught in stoppage. Re lease Foot Pedal, press Direction Lever down to temporarily re verse cable feed direction, and re-wind to relieve twist on Cable. Pull Direction Lever up (FORWARD) to continue. When Cable has trouble getting around tight bends in drain pipe.Press Motor Direction Switch (5) to Reverse while applying steady pressure to Cable. Keep in mind that this will reverse auto feed operation as well. Do for only a few seconds to pass bend. More time could cause tangling or kinks in the Drum. If problem persists, Cable is too large for pipe. Switch to a drain cleaner with a smaller cable. When Cable reach es clog in drain pipe.Do not force Cable through stoppage. Press Direction Lever to neutral position. Allow Cable to progress forward slowly, chew ing stoppage. Slow forward movement reduces stress on Cable, while cleaning better. Try back and forth Cable movement, using the Direction Lever (44-16).

Troubleshooting

ProblemProbable Cause(s)Solution(s) Motor cuts off during use.The motor may have been shut off by it’s internal thermal protec tion switch, or auto reset breaker.Turn motor off. Allow motor to cool off completely before restarting and stay clear of cable when turning motor back on. Cable kinks, twists, or breaks.1. Too much force on the cable. 2. Too much slack between Drain Cleaner and drainpipe inlet. 3. Cable used is wrong size for drain pipe. 4. Cable exposed to acid. 5. Cable worn out.1. Do not force cable. Let cutter tool do the work. 2. Move Drain Cleaner to within two feet of drainpipe inlet. 3. Change cable size. 4. Clean and oil cable regularly. 5. Replace cable Cable tangles in drum.1. Too much force on the cable. 2. Motor running in reverse. 3. Distributor tube frozen.1. Do not force cable. Let cutter tool do the work. 2. Retract Cable with the Motor Di rection Switch (5) in the Forward position. 3. Lubricate distributor tube bear ings.
Page 12 of the Chicago Electric Wireless Remote Switch (66508) user manual — Troubleshooting
Page 12 · click to enlarge
Page 12

Troubleshooting

ProblemProbable Cause(s)Solution(s) Power Cord GFCI trips when unit is plugged in or when Foot Pedal is pressed.1. Motor Direction Switch (5) defective. 2. Frayed Power Cord. 3. Short circuit in Motor. 4. Excess moisture touch ing Power Cord or Drain Cleaner. 5. Faulty GFCI unit.1. Repair or replace Motor Direction Switch. 2. Repair or replace Power Cord. 3. Have Motor repaired by a qualified technician; Re place Motor. 4. Remove moisture. 5. Replace Power Cord with GFCI. Motor does not operate.Pneumatic Foot Pedal may have a leak.Check for leaks in air line lead ing from Foot Pedal. Check for tears and holes in Foot Pedal. Replace if needed. The “Unbind/Normal” Switch does not work.The centrifugal switch re quires the motor to come to a complete stop before it will allow the direction of the motor to be changed.Move the “Unbind/Normal” Switch to the “Off” position and allow the motor to stop before changing from “Normal to Un bind” or visa versa. The Foot Pedal sticks.Overloading of the motor may cause the Foot Pedal to stick.Press the Foot Pedal several times to release it. Cable does not feed when Foot Pedal is pressed.1. Cable tangled in Drum. 2. Feed tension incorrect. 3. Feed roller frozen. 4. Cable worn out.1. Do not run Motor in reverse. Unplug Drain Cleaner and manually pull cable out until tangle is cleared. 2. Adjust feed tension Star Knob (44-13). If Knob is too loose, cable will slip. If too tight, rollers will wear pre maturely. 3. Clean and lubricated feed rollers. Replace worn roll ers. 4. When cable coils wear flat, cable should be replaced.
Page 13 of the Chicago Electric Wireless Remote Switch (66508) user manual — Auto Feed Maintenance
Page 13 · click to enlarge
Page 13

INSPECTION, MAINTENANCE, AND CLEANING

General

Before each use, 1. inspect the general condition of the Drain Cleaner. Check for loose screws, misalignment or binding of moving parts, cracked or broken parts, damaged electrical wiring, and any other condition that may affect its safe operation. If abnormal noise or vibration occurs, have the problem corrected before further use. Do not use damaged equipment.

Periodically recheck all nuts, bolts, and screws for tightness. 2.

After each use, clean the Drain Cleaner components with a wet, clean cloth. Wipe dry 3. when clean.

Always keep Cable (39a) well oiled by pouring oil directly into the Drum (38a). Then 4. push the Motor Direction Switch (5) to the NORMAL position. The Drum will rotate. Do this until the entire Cable is lubricated. Lubricate all other moving parts adequately to protect against corrosion, sand, grit, and other abrasive material.

Store unit in a clean and dry location. Cover unit with a cloth cover. 5.

The cable includes a Cable Stop (80) to prevent it from being overextended. Loosen 6. the Bolts (81), and remove Stop if removing the cable. When re-installing Cable, reat tach the Stop inside the drum when there are about two full turns of cable still in the drum.

Auto Feed Maintenance

Keep the auto feed mechanism free of excessive soil and grit. It is recommended that it be flushed with fresh water, followed by a light oiling of the moving parts. No disassembly is normally required. Failure to feed during operation can usually be traced to the build up of soil and grit. Over time, dirt can harden enough to stop roller rotation. Flushing with water, followed by liberal oiling can usually restore function. If disassembly is required, proceed as follows:

Remove the two bolts that hold the Front Cap (44-19A) and internal roller to the Case 1. (44-11A).

Slide the front Cap out of the Case and inspect and clean the roller as described 2. above.

Remove the four bolts that hold the End Cap (44-7A) and Guide Rollers (44-9) to the 3. Case (44-11A).

Slide the End Cap out of the Case and inspect and clean the three guide rollers as 4. described above.

Page 14 of the Chicago Electric Wireless Remote Switch (66508) user manual — PLEASE READ THE FOLLOWING CAREFULLY
Page 14 · click to enlarge
Page 14

While the Case is open, thoroughly clean and oil all parts and then reassemble in 5. reverse order.

Guide Roller Replacement

Guide Rollers (44-9) due to excessive use may be damaged to a point of failure and need replacement. Replace all three Guide Rollers at the same time.

Tangled Cable

If the Cable loops over itself in the Drum, it will not feed properly. With the motor stopped and cord unplugged, remove and reload the Cable by hand to restore proper functioning. If the Cable kinks, it is evidence of abuse and results from the use of too much pressure when drain cleaning, or use of the wrong size Cable for the drain pipe being cleaned. Do not force the Cable during use, let the cutter tool do the work.

Removing a Stuck Cable in the Drain Pipe

If the cable gets caught in the drain pipe move the Motor Direction Switch (5) to the Off 1. position. Then, once the drum has stopped turning, move the Motor Direction Switch (5) to the Reverse position to free the Cable.

If using the Power Cable Feed, putting the Motor in reverse will cause the feed Direc 2. tion Lever (44-16) to operate opposite of normal.

Press the Pneumatic Foot Pedal (14A) while pulling on the Cable. 3.

After the Cable is loose, move the Motor Direction Switch (5) back to the Forward 4. position.

PLEASE READ THE FOLLOWING CAREFULLY

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER NOR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.

Page 15 of the Chicago Electric Wireless Remote Switch (66508) user manual — Guide Roller Replacement
Page 15 · click to enlarge
Page 15

Main Unit Parts List Part Description Qty 1 Protect Shield 1 2 Belt 1 3 Belt Wheel 1 4 Bolt M6 x 10 1 5 Motor Direction Switch 1 6 Lock Nut M6 1 7 Motor 1 8 Lock Nut M10 4 9A Motor Holder 1 10 Spring 4 14A Pnuematic Foot Switch 1 15 GFCI 1 16A U Handle 1 17 Star Knob M10 x 35 2 18A Frame 1 20 Cotter Pin Ø3.2 x 25 2 21 Pipe Cap 2 22 Wheel 2 23 Washer Ø14 4 25 Hex Bolt M10 x 20 2 26 Star Nut M10 1 27 Cap Nut M6 2 28 Rubber Foot 2 29 Washer Ø6 4 30 Phillips Bolt M6 x 40 2 31 Bolt M10 x 50 1 32 Washer Ø10 14 33A Axle for Drum 1 35 Washer #1 1 36 Lock Nut M8 5 37A Drum Hub 1 38A Drum 1 39A Spring Cable 1 41 Hex Bolt M8 x 20 5

Part Description Qty 42A Cable Guide 1 44A Feed Unit 1 45 Retaining Ring 2 46 Pin 1 47 Pin Spring 1 48 Guide Spring 1 54 Spring Washer Ø10 2 55 Notched Washer 1 56 Inner Hex Bolt M8 x 8 2 57 Right Angle Guide 1 58 Cross-Head Bolt M5 x 10 1 59 Arrow Head Cutter 1 60 Bulb Auger 1 61 1-1/2” U-Cutter 1 62 1-1/4” Side Cutter Blade 2 63 Hex Bolt M10 x 70 4 64 Flat Washer 6 1 65 Block 4 66 Hinge A 2 67 Inner Hex Bolt M4 x 25 4 68 Hinge B 2 69 Tray 1 70 Washer #2 2 71 Cross-head Bolt M6 x 20 4 72 Sleeve 2 73 Wheel Shaft Cap 2 74 Waveform Washer 19 1 75 Washer 1 76 Spring Washer 5 1 77 Spring Washer 6 5 78 Phillips Screw M6X16 1 79 Washer 1 80 Cable Stop 1 81 Inner Hex Screw M4X12 4

Page 16 of the Chicago Electric Wireless Remote Switch (66508) user manual — Main Unit Assembly Drawing
Page 16 · click to enlarge
Page 16

Main Unit Assembly Drawing

Chicago Electric Wireless Remote Switch (66508) — Main Unit Assembly Drawing diagram (page 16)
Fig. 8 · Main Unit Assembly Drawing
Page 17 of the Chicago Electric Wireless Remote Switch (66508) user manual — Subassembly NO. 44A (feed unit)
Page 17 · click to enlarge
Page 17

Parts List for Subassembly No. 44A (Feed Unit)

Part Description Q’ty 44-1 Base 1 44-2 Inner Hex Bolt M6x14 6 44-3 Adapter 1 44-4A Axle for Guide Roller 1 44-5A Guide Screw 1 44-6 Cable Sleeve 1 44-7A End Cap 1 44-8A Screw 4 44-9 Guide Roller 3 44-10AScrew 2 44-11ACase 1 44-12ASide Cap 1 44-13 Star Knob M12 1 44-14AShaft 1 44-15 Shaft Sleeve 1

Part Description Q’ty 44-16 Direction Lever 1 44-17 Handle Cap 1 44-18 Spring 1 44-19AFront Cap 1 44-20 Bolt M6x16 2 44-21 Inner Hex Bolt M6x18 4 44-22 Cap 1 44-23 Small Spring 1 44-24 Nylon Sleeve 2 44-25 Steel Ball Ø10 1 44-26 Spring Washer Ø6 6 44-29 O-ring 8 44-30 Washer Ø8 2 44-31 Pin 3X10 1 44-32 Flat Washer 6 6

Subassembly NO. 44A (feed unit)

Chicago Electric Wireless Remote Switch (66508) — Subassembly NO. 44A (feed unit) diagram (page 17)
Fig. 9 · Subassembly NO. 44A (feed unit)
Page 18 of the Chicago Electric Wireless Remote Switch (66508) user manual — LIMITED 90 DAY WARRANTY
Page 18 · click to enlarge
Page 18

LIMITED 90 DAY WARRANTY

Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper installation, normal wear and tear, or to lack of maintenance. We shall in no event be liable for death, in juries to persons or property, or for incidental, contingent, special or consequential damages arising from the use of our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation of exclusion may not apply to you. This warranty is expressly in lieu of all other warranties, express or implied, including the warranties of merchantability and fitness.

To take advantage of this warranty, the product or part must be returned to us with transportation charges prepaid. Proof of purchase date and an explanation of the complaint must accompany the merchandise. If our inspection verifies the defect, we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will return repaired products at our expense, but if we determine there is no defect, or that the defect resulted from causes not within the scope of our warranty, then you must bear the cost of returning the product.

This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

  • 3491 Mission Oaks Blvd.
  • PO Box 6009
  • Camarillo, CA 93011
  • (800) 444-3353
Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Motor cuts off during use.The motor may have been shut off by it’s internal thermal protec­ tion switch, or auto reset breaker.Turn motor off. Allow motor to cool off completely before restarting and stay clear of cable when turning motor back on. p.11
Cable kinks, twists, or breaks.1. Too much force on the cable. 2. Too much slack between Drain Cleaner and drainpipe inlet. 3. Cable used is wrong size for drain pipe. 4. Cable exposed to acid. 5. Cable worn out.1. Do not force cable. Let cutter tool do the work. 2. Move Drain Cleaner to within two feet of drainpipe inlet. 3. Change cable size. 4. Clean and oil cable regularly. 5. Replace cable p.11
Cable tangles in drum.1. Too much force on the cable. 2. Motor running in reverse. 3. Distributor tube frozen.1. Do not force cable. Let cutter tool do the work. 2. Retract Cable with the Motor Di­ rection Switch (5) in the Forward position. 3. Lubricate distributor tube bear­ ings. p.11
Power Cord GFCI trips when unit is plugged in or when Foot Pedal is pressed.1. Motor Direction Switch (5) defective. 2. Frayed Power Cord. 3. Short circuit in Motor. 4. Excess moisture touch­ ing Power Cord or Drain Cleaner. 5. Faulty GFCI unit.1. Repair or replace Motor Direction Switch. 2. Repair or replace Power Cord. 3. Have Motor repaired by a qualified technician; Re­ place Motor. 4. Remove moisture. 5. Replace Power Cord with GFCI. p.12
Motor does not operate.Pneumatic Foot Pedal may have a leak.Check for leaks in air line lead­ ing from Foot Pedal. Check for tears and holes in Foot Pedal. Replace if needed. p.12
The “Unbind/Normal” Switch does not work.The centrifugal switch re­ quires the motor to come to a complete stop before it will allow the direction of the motor to be changed.Move the “Unbind/Normal” Switch to the “Off” position and allow the motor to stop before changing from “Normal to Un­ bind” or visa versa. p.12
The Foot Pedal sticks.Overloading of the motor may cause the Foot Pedal to stick.Press the Foot Pedal several times to release it. p.12
Cable does not feed when Foot Pedal is pressed.1. Cable tangled in Drum. 2. Feed tension incorrect. 3. Feed roller frozen. 4. Cable worn out.1. Do not run Motor in reverse. Unplug Drain Cleaner and manually pull cable out until tangle is cleared. 2. Adjust feed tension Star Knob (44-13). If Knob is too loose, cable will slip. If too tight, rollers will wear pre­ maturely. 3. Clean and lubricated feed rollers. Replace worn roll­ ers. 4. When cable coils wear flat, cable should be replaced. p.12

Ask about the Chicago Electric Wireless Remote Switch (66508)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Chicago Electric Wireless Remote Switch (66508)

Be the first to ask — other owners or our team will answer.

Original document

Chicago Electric Wireless Remote Switch (66508) manual PDF

18 pages·1.2 MB·Power Tool·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…