Series
User’s Guide
Be sure to read “Safety Precautions” inside this guide before trying to use your Handheld Terminal. After reading this guide, keep it in a safe place for future reference.

CE operating system or its derivative work, which use is governed by a license granted by Extended Systems Inc.
Copyright 1993-2000 Datalight, Inc., All Rights Reserved.
U.S. Patent Office 5,860,082

Congratulations upon your selection of this CASIO product. Be sure to read the following Safety Precautions before trying to use it for the first time.
The following are the meanings of the markings and symbols used in these Safety Precautions.
This symbol indicates information that, if ignored or applied incorrectly, creates the danger of death or serious personal injury.
This symbol indicates information that, if ignored or applied incorrectly, creates the possibility of death or serious personal injury.
This symbol indicates information that, if ignored or applied incorrectly, creates the possibility of personal injury or property damage.
Warning
Disassembly and Modification

Foreign Objects
Also, never connect or disconnect peripherals to the Handheld Terminal while they are wet. Water getting into the Handheld Terminal or its peripherals creates the danger of fire and electric shock. Laser Light
Interference with the Operation of Other Equipment
(Using Wireless Data Communication)

Foreign Objects
immediately wash your mouth with water and then consult a physician. – Should liquid from the LCD panel accidentally get into your eyes or onto
your skin, immediately rinse for at least 15 minutes with clean tap water and then consult a physician.

Danger

Replace only with same or equivalent type recommended by CASIO. Dispose of used batteries according to the local regulation.

Warning

Caution
Dust built up between the prongs can lead to the danger of fire.
Caution

Your Handheld Terminal and its options is a precision digital instrument. Improper operation or rough handling can cause problems with data storage and other problems. Note and observe the following precautions to ensure proper operation.
Doing so can cause data to be lost. When the battery goes low, charge it as soon as possible.
Dead batteries can leak, leading to malfunction and damage to the Handheld Terminal.
Use outside of the specified temperature range creates the risk of malfunction.
The following conditions create the risk of damage to the Handheld Terminal.
— Large amounts of static electricity
— Extreme heat or extreme cold
— Sudden temperature extremes
— Large amounts of dust
To clean the Handheld Terminal, wipe it with a dry cloth, or a cloth moistened in a weak solution of water and a mild neutral detergent. Wring all excess moisture from the cloth before wiping.
— High humidity


We, the undersigned.
certify and declare under our sole responsibility that the following equipments:
are tested and found to conform with the essential requirements for protection of health and the safety of the user and any other persons and Electromagnetic Compatibility, as included in following standards:

Products are for distribution within all member states of the EU.
France limited to 2446.5-2483.5 Mhz Indoor use. Belgium limited to 2400-2483.5 Mhz Indoor, 2460-2483.5 Mhz Outdoor use. The Netherlands limited to 2400-2483.5 Mhz Indoor use with no license, 2451-2471.0 Mhz Outdoor use with license.
The information described above dates from January 2003 and may be subjected to future changes.
CASIO Europe GmbH Bornbarch 10, D-22848 Norderstedt, Germany


Be sure to perform the following steps before trying to use the Handheld Terminal for the first time.
1.When unpacking, make sure that everything is included.
Open the box and make sure that all the items shown here are included.
The stylus is attached to the Handheld Terminal.
Large-capacity battery pack cover
User's Guide (this manual)
Touch Screen Protective Sheet
2.Charge the battery pack.
Charge the separately available battery pack (DT-5123BAT or DT-5124LBAT). You can use the Dual Battery Charger, or the Cradle-type Battery Charger, or the Bridge Satellite Cradle to charge a battery pack.
For information using these options for charging, see pages 38, 47, and 51.
3.Load the battery pack into the Handheld Terminal.
1 Turn the battery pack lock switch to the "FREE" position, and then remove the battery pack cover.
Handheld Terminal Stylus · Neck Strap

2 Load a battery pack (DT-5123BAT) or large-capacity battery pack (DT-5124LBAT). Take care that the battery pack is oriented correctly when you load it. In addition, load the battery back while making sure that the end of the battery pack removal tape is protruding above the battery pack.

3 Replace the rechargeable battery pack cover as shown in the diagram and then return the rechargeable battery pack cover switch to the “LOCK” position. When loading a large-capacity rechargeable battery pack, mount the large-capacity rechargeable battery pack cover.

4.Hold down the power key for about one second to turn on the Handheld Terminal.
Using the stylus Tap: Lightly tap with the stylus once on the touch screen. Tap and Hold: Hold the tip of the stylus on the touch screen without moving it. Drag: Hold the tip of the stylus on the touch screen as you drag from one location to another. This operation is the same as writing with a pencil on a piece of paper.

Bridge Basic Cradle (IT-560IOE)
Required AC Adaptor (AD-S42120A)
IT-569CHGE
Required AC Adaptor (AD-S42120A)

DT-5124LBAT (Large-capacity Battery Pack)
DT-5122CHGE
Required AC Adaptor (MPC-577ADP)
DT-5123BAT (Battery Pack)

DT-887AXA DT-888RSC DT-380USB
Bridge Satellite Cradle Cable/RS-232C Dsub-9Pin (Female) Bridge Daisy Chain Cable USB Cable
Level converter Cable

Left Front Right Back


This lamp indicates the charge status of the battery pack. Red: Charging Green: Charging complete
Indicates the result of a barcode or other read operation. Red: Read error Green: Read successful
Outputs audio.
4 LCD Panel/Touch Screen
Shows text, operation indicators, etc. Also, operations can be performed and text can be input using the supplied stylus.
Hold down for about one second to turn the power on or off.
Inputs audio.
Press to register an input value and advance to the next step.
8 Power supply terminal
Used to supply power from the Cradles and Cradle-type Battery Charger.
Use these keys to input numbers and letters.
Press to clear all key inputs.
Press when switching to the input mode. In combination with the numeric keys, each setting is performed while it is also used when starting application which have been registered beforehand.
Press to perform a barcode read operation. This is also pressed before performing full reset.

This port is used for IR data communication with another Handheld Terminal or the Cradles.
Emits a laser that reads bar codes.
Connected to the separately sold level converter cable.
Used during input from touch screen.
17 Neck strap hole
Attach the neck strap here.
Confirms object being photographed when photographing with the camera lens facing towards you.
Used when photographing or capturing images. (IT-500M30CR/ M30CF/M30CB only)
Sounds a buzzer.
Press to reset the Handheld Terminal.
22 Battery Pack Cover Lock Switch
Slide the switch to lock and release the battery pack cover.
23 Battery Pack Cover
Covers the compartment that holds the battery pack.

Your Handheld Terminal uses two types of battery: a battery pack and a memory backup battery. The battery pack is used to power normal operations and to store data, while the memory backup battery provides the power required to maintain memory contents when the battery pack power is unable to supply power for some reason.
The operating power is supplied by a battery pack. You can choose between a battery pack (DT-5123BAT) and a large-capacity battery pack (DT-5124LBAT).
The backup battery is installed inside of the Handheld Terminal.
This guide uses the following terms to refer to the batteries. Battery Pack: Rechargeable battery pack (DT-5123BAT or DT-5124LBAT) for normal operations and data storage Backup Battery: Built-in battery for memory backup
When the battery pack power goes low, immediately charge it or replace it with a charged battery pack. You can use the Dual Battery Charger, the Cradle-type Battery Charger, the Bridge Basic Cradle, or the Bridge Satellite Cradle to charge a battery pack. See the sections of this guide that cover the Dual Battery Charger, the Cradle-type Battery Charger, the Bridge Basic Cradle, and the Bridge Satellite Cradle for information about how to use them for charging.
Important!
Always keep backup copies of all important data!

1.Make sure that the Handheld Terminal is turned off.
If the power is on, press the power key to turn it off.
2.Turn over the Handheld Terminal.
3.Turn the battery pack lock switch on the back of the Handheld Terminal to the "FREE" position, and then remove the battery pack cover.
4.Remove the battery pack as shown in the illustration.
5.Taking care to ensure it is oriented correctly, load a new battery pack into the Handheld Terminal. Load the battery back while making sure that the end of the battery pack removal tape is protruding above the battery pack.

6.Replace the rechargeable battery pack cover as shown in the diagram and then return the rechargeable battery pack cover switch to the “LOCK” position.
Loading the large-capacity battery pack into the Handheld Terminal After loading the large-capacity battery pack, you need to use the special large-capacity battery pack cover in place of the standard battery cover. Attachment and removal of the large-capacity battery pack cover are the same as those for the standard battery pack cover.

Be sure to attach the neck strap and use it to protect against dropping the Handheld Terminal when carrying it around.
1.Pass the thin cord of the neck strap through the neck strap hole on the back of the Handheld Terminal.
2.Pass the other end of the strap (the part you put around your neck) through the loop formed by the thin cord.
Do not swing the Handheld Terminal around holding the neck strap.

Attach the touch screen protective sheet according to the procedure described below.
1.Switch the power of this unit OFF and remove any dust or other debris from the touch screen.
2.Peel off the film (green) affixed to the front of the protective sheet.
3.With its front side (the side to which the film was attached) towards you, fix the upper and lower sides of the protective sheet properly to the touch screen. If you encounter difficulties fixing it properly, carefully bend the slight projections at the four corners of the protective sheet to the front.
Front

Whenever the response of the touch screen is poor, or the operations being executed do not match with the location you are tapping on the touch screen, please recalibrate the alignment of the touch screen using the following method.
∗The following screen can also be displayed by consecutively tapping “Stylus” on the
control panel.



Perform the following procedures to adjust display contrast to make display colors more vivid and easier to see.
∗In order to continue to make adjustments, press the “2” key or “3” key after again
first pressing the “Fn” key.
∗Contrast settings can also be made by consecutively tapping “Brightness” on the
control panel.
You can use the following procedures to adjust display brightness to make it easier to read under different lighting conditions.
∗In order to continue to make adjustments, press the “5” key or “6” key after again
first pressing the “Fn” key.
∗Brightness settings can also be made by consecutively tapping “Brightness” on the
control panel.
The display auto dimmer automatically lowers display brightness if you do not perform any operation for a specific amount of time. This helps to conserve battery power. You can use the following procedure to specify the amount of that should be allowed to pass before auto dimming is performed.

1.After turning on the power, position the laser scanner close to a bar code and then press the trigger key.
2.The laser emits light and scans the bar code. If scanning is completed normally, Indicator 2 displays a green light and a buzzer sounds. If the bar code was not scanned properly, Indicator 2 indicates a red light.

LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER 1mW 650nm IEC650825-1:1993+A1:1997
Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. • The laser light emitted by this laser scanner has a maximum output of less than 1 mW and a wavelength of 650 nm.
Position the laser scanner close to the bar code when scanning small bar codes. Position the laser scanner at a distance from the bar code so that the bars enter the light when scanning large bar codes.


IR data communication can be used to transfer data between two Handheld Terminals. When performing IR data communication, orient the IR ports of both Handheld Terminals so they are pointing directly at each other. The ports can be in direct contact with each other, or they can be separated by up to 1 meter (3'31⁄2") (up to 25cm (97⁄8") for 4Mbps data communication).

BluetoothTM protocol can also be used to transfer data between two Handheld Terminals. With BluetoothTM the two Handheld Terminals should be located within about three meters (9'103⁄8") from each other, as long as there is nothing blocking the path between them.
Observe the following precautions to help ensure that data communication is successful.
Because BluetoothTM and RF wireless LAN use the same frequency band (2.4GHz), radio interference can occur if there is a wireless LAN device nearby. This can result in lower data communication speeds, or even make it impossible to establish a connection. If this happens, try the following countermeasures.

Resetting the Handheld Terminal is the same as restarting a computer. Performing a reset causes all unsaved inputs and edits to be lost, but data that is already stored in the memory as well as all settings should be unaffected. Use reset to restore normal operation whenever the Handheld Terminal operates abnormally due to misoperation or some other reason.
Use the stylus to press the reset switch on the back of the Handheld Terminal. This starts the reset operation.
If reset does not find a memory problem The Handheld Terminal restarts, and normal operation is restored.
If reset finds a memory problem A message like the one shown below appears on the display when the reset operation discovers a memory problem.
Memory Corruption Warning A problem with memory contents has been found. Press [Trigger key] to continue with
normal system operation. Note that if the system determines that user memory cannot be repaired, it will delete all
installing memory.
When this message appears, press the Trigger key to continue with the reset operation. Note, however, that reset may not be successful depending on the condition of the memory. In this case, perform the full reset operation described on the next page.
Trigger key

Performing a full reset initializes memory. This means that all data stored in the memory (RAM) is deleted and all the settings are returned to their initial factory defaults.
Perform a full reset whenever any one of the following conditions exists.
Important!
Performing a full reset deletes all data currently stored in the memory (RAM). If possible, backup data of the Handheld Terminal to a computer, Flash Memory, a memory card, or some other medium before performing a full reset.
1.Hold down the power key and push down the reset switch for about one second, until the message shown below appears on the display.
Memory All Clear Warning Proceeding with this operation initializes memory.
or [CLR key] to cancel.
2.Press the Trigger key. This causes the message shown below to appear.
stored in memory. Press [Trigger key] to proceed
or [CLR key] to cancel.
3.Press the Trigger key again.
Trigger key · Trigger key

Model: IT-500M30, IT-500M30R, IT-500M30B, IT-500M30CR, IT-500M30F, IT-500M30CF, IT-500M30CB CPU: Intel® PXA255 Application Processor (400MHz max.) Memory: 32MB RAM; 32MB Flash ROM (FlashFX built in) OS: Microsoft® Windows® CE.NET operating system, English Version Display: 3.5-inch, 240 × 320-dot 2-Way TFT color LCD Laser scanner:
Scanned codes: EAN (JAN), UPC, Codabar (NW-7), ITF, CODE39, CODE128, MSI,IATA, Industrial 2 of 5, EAN128 Scanning distance: Within approximately 40-300 mm (15/8"-117/8") Serial Port:
Interface: IrDA Ver. 1.1 Standard Synchronization: Asynchronous, frame synchronization Transfer Rate: Up to 4Mbps (max.) BluetoothTM Data Communication (IT-500M30B/M30CB) :
Protocol: BluetoothTM Specification Ver.1.1 Range: Approximately 3 m (9'103/8") (depends on radio wave conditions and environment) Output: 3dBm max. (PowerClass2) Wireless Communication (IT-500M30R/M30CR/M30F/M30CF):
Standard: Complies with IEEE 802.11b Diffusion Modulation: Direct Sequence Spread Spectrum Frequency: 2.400-2.4835 GHz Transmission Rate: Max. 11 Mbps Transmission Distance: 50 m (164'55/8") indoors, 150 m (493'5") outdoors (varies according to usage environment) No. of Channels: 13 (of which 3 channels can be used simultaneously) IT-500M30R/M30CR 11 (of which 3 channels can be used simultaneously) IT-500M30F/M30CF Other Functions: Roaming function between multiple access points Digital Color Camera (IT-500M30CR/M30CF/M30CB):
Approx. 350,000 pixels Power Requirements:
Power Supply: DT-5123BAT Battery Pack DT-5124LBAT Large-capacity Battery Pack Memory Backup: Rechargeable Lithium Battery (Built-in) Power Consumption: 5A DC, 3.7 to 5V

Battery Life:
Main battery:
Approximately 4 hours (DT-5123BAT)* Approximately 8 hours (DT-5124LBAT)* IT-500M30R/M30CR/M30F/M30UCF
Approximately 4 hours (DT-5123BAT)* Approximately 8 hours (DT-5124LBAT)* Approximately 3 hours (DT-5123BAT)** Approximately 7 hours (DT-5124LBAT)** *In the case of Standby (20): Operation (1): Scanning (1) **In the case of Standby (20): Operation (1): Scanning (1): Wireless (1) Memory backup: Data Protection (RAM): 10 minutes (when
no power is being supplied by the installed battery) Operating Temperature: –10°C to 50°C (–4°F to 122°F) Operating Humidity: 10% to 80% RH (non-condensation) Drop Durability: 1.0 m (3'31/2") Dust and Water Splash Proof:
IEC529, IP54 Standard *When all connectors and covers are closed. Dimensions:
Approximately 78(W) × 162(D) × 20(H) mm (3"W × 85⁄8"D × 17⁄8"H) (not including projections) Weight:
Approximately 260g (9.2oz)(IT-500M30/M30B/M30CB) Approximately 280g (9.9oz)(IT-500M30R/M30CR/M30F/M30CF)

The optionally available Bridge Satellite Cradle (IT-564IOE)/Bridge Basic Cradle (IT-560IOE) make it possible to transfer system data and file data between the IT-500 and a computer over an RS-232C connection or USB connection (USB only for the IT-5601OE) (download or upload). You can also use the Bridge Satellite Cradle/Bridge Basic Cradle to charge the battery pack installed on the IT-500. An optionally available wall mount unit lets you mount the Bridge Satellite Cradle/ Bridge Basic Cradle on a wall.
1 2 3 4


This port accepts connection of a USB cable for connection to a computer for transfer of system data and file data. Use of the USB port requires installation of a special driver on the PC.
2 RS-232C Port (IT-564IOE only)
This port accepts connection of an RS-232C cable for connection to a computer for transfer of system data and file data. Use of the RS-232C port requires installation of a special driver on the PC.
3 RS-422C Port (IT-564IOE only)
This port is used when connecting to another Bridge Satellite Cradle.
4 AC Adaptor Jack
Connect the AC adaptor here.
5 Wall Mount Unit Fastening Plate
The holes in this plate accept screws that secure the wall mount unit in place.
6 Terminal Detect Switch
This switch detects when the IT-500 is seated correctly on the Cradle.
Power is supplied to the IT-500 via these contacts.
8 Power Indicator Lamp
This lamp indicates the power status and the mounting status of the IT-500. Off: Power off Green: Power on, IT-500 mounted correctly Red: Power on, IT-500 not mounted This lamp shows that the IT-500 is performing data communication via a serial interface (RS-232C/RS-422). Off: No data communication being performed Green flashing: Data communication in progress Red: Problem with a connection between two Cradles
9 Communication Indicator Lamp (IT-564IOE only)
10 System Status Indicator Lamp
This lamp indicates whether the system is operating normally. Regardless of whether or not an IT-500 is mounted this lamp indicates the system status and whether or not a communication operation with the system can be performed. Off: System is not operating. Green: System is operating.
This port transfers data with the IT-500 IR port non-contact data communication.
Turns the power on and off.
13 DIP Switches (IT-564IOE only)
Use these switches to configure the Cradle as required.

Use the AC adaptor available as option for the Bridge Satellite Cradle/Bridge Basic Cradle to supply the power to it. Always make sure that the power is being supplied to the Bridge Satellite Cradle/Bridge Basic Cradle by the AC adaptor before performing any type of data communication operation with the IT-500. The IT-500 draws the power via the Bridge Satellite Cradle/Bridge Basic Cradle during data communication.
1.After making sure that the Bridge Satellite Cradle/Bridge Basic Cradle power switch is turned off, plug the AC adaptor into the AC adaptor jack on the back.

When using the RS-232C port
2.Next, plug the AC adaptor into a power outlet.

POWER DATA LINE System Status Indicator Lamp
Communication Indicator Lamp (IT-564IOE only)
Be sure to keep the Bridge Satellite Cradle/Bridge Basic Cradle connection ports covered whenever you are not using them.

4.Turn on the power. This causes the Bridge Satellite Cradle/Bridge Basic Cradle power indicator lamp to light in red.
5.Making sure that their two IR ports come into contact with each other, place the IT-500 onto the Bridge Satellite Cradle/Bridge Basic Cradle. This causes the Bridge Satellite Cradle/Bridge Basic Cradle power indicator lamp to light in green.
When charging is initiated, indicator 1 on the IT-500 lights up in red. When charging has been completed, indicator 1 on the IT-500 changes color from red to green.
In order to ensure successful communication, avoid using cellular phones or other devices that emit radio wave in the area where you are performing IR data communication.
If you need to use such a device, move away from the communicating Handheld Terminals. In case of a cellular phone, keep it at least 30cm (117⁄8") away.
Shorting the power contacts can damage the Cradle.

Dismounting the bottom cover of the Bridge Satellite Cradle exposes the DIP switches. You can change the ON/OFF settings of the DIP swiches to set the configuration. Please, set after swiching OFF the power.
1 2 3 4 5 6 7 8
Not used (Always off)
Not used (Always off)
ON
Setting Intermediate Unit Daisy Chain Disabled/Termination
ON
Setting Host Computer Daisy Chain
4 OFF OFF
ON
Bridge Satellite Cradle Data Rate
Setting 115,200bps *Initial factory default setting
2 OFF
Important!

The following procedure explains how to use the optional wall mount unit (DT-891WH) to configure the Bridge Satellite Cradle/Bridge Basic Cradle for a wall-mounted configuration.
2.Drive one of the provided screws into the wall at the location where the upper hole of the wall mount unit to be when you mount the unit on the wall.
Do not drive the screw into the wall all the way. Keep a space of about 2mm (1⁄8") between the head of the screw and the wall surface.
3.Hook the upper wall mount unit hole onto the upper screw.
4.Drive the other screw into the wall at the location where the lower hole is located.
Screws · 2mm (1/8")

5.Drive the upper screw and lower screw into the wall the rest of the way.
1.Loosen the upper screw and lower screw.
2.Raise the Bridge Satellite Cradle/Bridge Basic Cradle and remove it from the screws.

Use the modular cable for the connections. You can daisy chain multiple Bridge Satellite Cradles by connecting the C-OUT port of the first unit that is the nearest to the host computer to the C-IN port of the next unit that is sitting to the first unit with DT-888RSC cable(Daisy chain connection cable) as shown in the figure below.

Daisy chain connection cables (DT-888RSC)
You can use optional daisy chain connection cables (DT-888RSC) to link up to eight Bridge Satellite Cradles.

1. IR Data Communication Interface: IR interface Protocol: IrDA Ver. 1.1 Standard Synchronization: Asynchronous Transfer Rate: 9,600, 115,200, 4Mbps (4Mbps is possible during a USB connection with the host computer only.) 2. USB Protocol: USB Ver1.1 Standard Transfer Rate: 12Mbps (max.) 3. RS-232C (IT-564IOE only) Protocol: Full duplex Synchronization: Asynchronous Transfer Rate: 115,200bps 4. RS-422 (IT-564IOE only) Protocol: Full duplex Synchronization: Asynchronous Transfer Rate: 115,200bps 5. Charging Charging System: Fixed-voltage (with current limiter) Charge Time: Approximately 4 hours (battery pack) Approximately 8 hours (large-capacity battery pack) 6. Power Supply Power Requirement: AC adaptor (AD-S42120A) Power Consumption: DC12V approximately 1000mA (IT-564IOE) DC12V approximately 850mA (IT-560IOE) Output to Handheld Terminal: DC5V 1500mA (max.) 7. AC Adaptor Model: AD-S42120A Input: 100V to 240V AC 50/60Hz Output: 12V DC 3500mA 8. Dimensions and Weight Dimensions:
(43⁄8"W × 41⁄8"D × 5"H) Wall Mount: Approximately 110(W) × 148(D) × 153(H) mm
(43⁄8"W × 57⁄8"D × 6"H) Weight: Desktop: Approximately 390g (13.8oz) (IT-564IOE) 370g (IT-560IOE) Wall Mount: Approximately 550g (19.4oz) (IT-564IOE) 530g (IT-560IOE) 9. Operating Environment Temperature: 0°C to 40°C (32°F to 104°F) Humidity: 30% to 80% RH (non-condensation)

The optionally available Cradle-type Battery Charger (IT-569CHGE) lets you charge the Handheld Terminal’s battery simply by placing the Handheld Terminal onto the charger. An optional wall mount unit lets you mount the Cradle-type Battery Charger on a wall.


1 AC Adaptor Jack
Connect the AC adaptor here.
2 Wall Mount Unit Fastening Plate
The holes in this plate accept screws that secure the wall mount unit in place.
3 Terminal Detect Switch
This switch detects when the IT-500 is seated correctly on the Cradle.
Power is supplied to the Handheld Terminal via these contacts.
5 Power Indicator Lamp
This lamp indicates the power status and the mountting status of the Handheld Terminal. Off: Power off Red: Power on, Handheld Terminal not mounted Green: Power on, Handheld Terminal mounted correctly
Turns the power on and off.
4 Power Contacts · 6 Power Switch

Use the special AC adaptor for the Cradle-type Battery Charger to connect to a wall outlet.
1.After making sure that the Cradle-type Battery Charger power switch is turned off, plug the AC adaptor into the AC adaptor jack on the back of the charger.

2.Next, plug the AC adaptor into a power outlet.
3.Turn on the power. This causes the Cradle-type Battery Charger power indicator lamp to light in red.

4.Making sure that their power contacts come into contact with each other, place the Handheld Terminal onto the Cradle-type Battery Charger. This causes the Cradle- type Battery Charger power indicator lamp to light in green.
When charging is initiated, indicator 1 on the IT-500 lights up in red. When charging has been completed, indicator 1 on the IT-500 changes color from red to green.
Take care to avoid allowing the Cradle-type Battery Charger power contacts to become connected to each other, which creates a short.
Shorting the power contacts can damage.
Power switch (OFF) · Power contacts

To wall mount the Cradle-type Battery Charger, use the same procedure as that described for the Bridge Satellite Cradle (IT-564IOE)/Bridge Basic Cradle (IT-560IOE) on page 41.
(43⁄8"W × 41⁄8"D × 5"H) Wall Mount: Approximately 110(W) × 148(D) × 153(H) mm
(43⁄8"W × 57⁄8"D × 6"H) Weight: Desktop: Approximately 360g (12.7oz) Wall Mount: Approximately 520g (18.3oz) 5. Operating Environment Temperature: 0°C to 40°C (32°F to 104°F) Humidity: 30% to 80% RH (non-condensation)

The optionally available Dual Battery Charger (DT-5122CHG) allows for serial charging of two rechargeable battery packs.




Top · Front · Back

1 Charge Indicator Lamp
This lamp indicates the charge status of the battery pack(s). Off: Not charging Red: Charging Red Flashing: Battery pack problem Green: Charging complete
2 AC Adaptor Jack
Connect the AC adaptor here.
3 Dual Battery Charger Connection Port
Use this port to connect multiple Dual Battery Chargers to each other.
4 Connection Bracket Attachment Holes
The connection bracket attaches here when you connect multiple Dual Battery Chargers to each other.

1.Plug the other end of the AC adaptor into the AC adaptor jack of the Dual Battery Charger.
2.Plug the optional AC adaptor into a wall outlet.
3.Taking care that the battery pack is oriented correctly, insert it into the Dual Battery Charger.
This causes the Charge Indicator Lamp to light in red, indicating that charging has started.

You can connect up to three Dual Battery Chargers. Doing so makes it possible to supply power to all the Dual Battery Chargers using one AC adaptor.
1.As shown in the illustrations below, remove the connector covers of the Dual Battery Chargers you want to connect to each other.

2.Connect the two Dual Battery Chargers as shown below.

3.Turn over the connected Dual Battery Chargers and attach a connection bracket, securing it in place with screws.
You can repeat the above steps to connect up to 3 Dual Battery Chargers.


AC adaptor MPC-577ADP Consumption Current:
Approximately 420mA 4. Operating Environment: Temperature:
0°C to 40°C (32°F to 104°F) Humidity:
30% to 80% RH (non-condensation) 5. Dimensions and Weight: Dimensions:
Approximately 110(W) × 100(D) × 53.5(H) mm (43⁄8"W × 4"D × 21⁄8"H) Weight:
Approximately 163g (5.8oz)

Your Handheld Terminal supports use of two battery pack types of different capacity. You can select the one that best suits your needs in terms of operating time, the type of options you need to use, etc. When using the large-capacity battery pack, you need to use the special large-capacity battery pack cover that comes with the battery pack (DT-5124LBAT).
Store a battery pack in its special soft case whenever you are not using it.
Model:
DT-5123BAT Rated Capacitance:
900mAh Rated Voltage:
3.7V Dimensions:
Approximately 27.9(W) × 51.2(D) × 12.4(H) mm (11⁄8"W × 2"D × 1⁄2"H) Weight:
Approximately 32g (1.1oz) Bundled Item:
Model:
DT-5124LBAT Rated Capacitance:
1800mAh Rated Voltage:
3.7V Dimensions:
Approximately 27.9(W) × 51.2(D) × 23.0(H) mm (11⁄8"W × 2"D × 7⁄8"H) Weight:
Approximately 57g (3.1oz) Bundled Item:
Soft case · Soft case

The separately sold Level Converter Cable (DT-5180RSC) can be used to connect this Handheld Terminal to a serial port of your computer.
1.Open the serial port cover of the Handheld Terminal and connect the Level Converter Cable.
Connect to RS-232C cable
2.Attach the hook to the neck strap.
3.Connect the other end of the Level Converter Cable to an RS-232C cable connected to a serial port of your computer.

CASIO COMPUTER CO., LTD.
6-2, Hon-machi 1-chome Shibuya-ku, Tokyo 151-8543, Japan
PN410372-002 MO0304-002002B Printed in Japan
Printed on recycled paper.
Owners and our team usually reply within a day — and your question helps the next person too.