Instruction/ maintenance manual of the product 40QNQ Carrier
Go to page of 24
40QNC / 38HDF 40QNQ / 38QR F High - - - W all Du ct Fr ee Split Sys tem Size s 018 to 036 Installation Instructions 40QNC, QN Q Unit NOTE : Read the en tire instru ction man ual b efore startin g th e installatio n.
2 DIMENSIONS - - INDOOR A08433 Model S ize W In. (mm) H In. (mm) D In. (mm) Operat ing W eight lb (kg) 18k 42.5 (1080) 11.6 (295) 7.9 (201) 31 (14.1) 24k 42.5 (1080) 11.6 (295) 7.9 (201) 31 (14.1) 30k 57.5 (1461) 13.4 (340) 9.5 (241) 51 (23.2) 36k 57.
3 CLEARANCES - - INDOOR min. min. min. min. 4i n . 4i n . 80 in. 8i n . A08357 Fig. 3 - - 40QNC,QN Q Unit Cl ear ance s CLEARANCES - - OUTDOOR A D B Air-inlet Air-outlet C E A08436 UNIT Coil Facing Wall - - - in.
4 Th ese installatio n instru ction s cov er the installatio n of th e matched system s listed in table 2. Parts List Ind oor Unit The fol lowing it ems a re i nc lude d with the i ndoor unit: T ab le.
5 Refrig eran t Charge Th e 38H DF and 3 8 QRF u nits can be matched with mu ltiple outdoor unit s and thus addit ional c har ge might be re quire d when ma tc hed wi th t he 40QNC or 40Q NQ uni ts . T able 6 – A ddit ional Char ge Add itional C harge l b (kg ) Unit S ize 38HD F 38QRF 018 1.
6 INST ALLA TION Compl ete Pr e- - in stall ation Ch ecks 1. Unpack Uni t - - Stor e the i ndoor and outdoor unit s in the orig inal p ackag ing u ntil it is mo ved to th e fin al site fo r in- stallation . 2. Ins pect Shi pment - - U po n receipt o f shipm ent, ch eck th e indoor and outdoor unit s f or dam age .
7 point A or B as s hown in Fig. 12 or Fig. 13. Dr il l the hole at a sl ope so that t he outsi de end is 1/2 inc h (13 mm) lowe r than ins ide end t o ensur e opti mal dra ina ge. Ref e r t o Fig. 14. Side O r Bott om Pipi ng Rem ove the knoc kout in the uni t and dri ll a 2- - 1/2 i nch (63.
8 Mo unting Uni t on W all The uni ts c an a ls o be mount ed on t he wa ll us ing the accessory mo un ting k it. Comp lete Ou tdoor Refri geran t Pipi ng Co nn ec- tions Foll ow the f oll owi ng gener al guide line s: 1. Us e re fri gera nt gr ade fi eld – s upplie d tubing.
9 38QRF Units 1. Assem ble th e con necto r tub es to th e factory su pp lied filter dri er by br az ing t he f ac tory s upplie d fla re c onnec tor s to the inlet an d o utlet fo r the filter d rier (see Fig . 19 ) A09507 Fig. 19 - - 38QRF018 - - 036 Connec tor T ube Ass em bly 2.
10 Control W iring Th e con trol circu it is 24 vo lts AC (m inim um 4 0 V A ) su pp lied fro m the i ndoor unit. 1. Ma ke sur e you have e nough c ontr ol wire s to cove r the dis - ta nce be twe en the indoor a nd outdoor unit .
11 T able 10 – 38HDF / 38QRF Ele ctr ical Dat a 38HD F / 38QR F UNIT SIZE V --- P H --- H z VOL TAGE RANGE* COMPRESS OR OUTDOOR F AN MOTOR MIN C KT AMPS FUSE/ HACR BKR AMPS RLA LRA FLA NE C Hp kW Out Min Max 018 208/230 - - - 1 - - - 60 187 253 9.0 48.
12 A08367 Fig. 24 - - 40QNC01824 Mat ched w it h 38HDF T ypic al W ir ing Sch emat ic.
13 Optional on 38QRF018/024 Models A08368 Fig. 25 - - 40QNQ018, 024 Mat che d with 38Q RF T ypic al W ir ing Sc hemat ic.
14 A08369 Fig. 26 - - 40QNC030, 036 Matc hed wit h 38HDF T ypic a l W ir ing Sch emat ic.
15 Optional on 38QRF0036 Models Standard on 38QRF030 A08370 Fig. 27 - - 40QNQ030, 036 Matc hed wit h 38QRF T ypic al Wi ri ng Sche mat ic.
16 Run Power W i ring for Ind oor Unit Be su re field wirin g com plies with lo cal b uild ing co des an d NEC , and u nit vo ltage is within lim its sh ow n in T able 11.
17 A Wal l Han gi ng Br ac k e t H ook Ho l e Re t a i n e r C lip Re t a i n e r Cl i p B UNIT SIZE DIMENS ION AB 40QNC01824 13. 4 10.6 40QNC030 12.2 12. 2 40QNC036 12.2 12. 2 40QNQ018 13.4 10. 6 40QNQ024 13.4 10. 6 40QNQ030 12.2 12. 2 40QNQ036 12.2 12.
18 A09512 Fig. 31 - - Contr ol Wi ring Bet wee n Indoor and Outdoor Unit s Up to s ix unit s c an be dais y - - cha ined a nd contr olle d from one wi red c ontrol .
19 Zone Manager If a Zone M ana ger is r equi red, the f ollowi ng ste ps should be per form ed at t he sam e ti me t he indoor c ontrol a nd powe r wir ing are bein g co nn ected : 1. Pl ug the com munic at ion boa rd to t he J8 a s shown i n Fig. 33 2.
20 ST A R T - - UP Pr eliminar y Che cks 1. Che c k conde nsa te dra inage s yste m; on t he opposit e s ide of the d rain co nn ectio n, in sert a water b ottle u p in to th e fan coil u nit an d fill th e d rain p an. W ater m ust flow stead ily; if not, che ck the pipe s lope or inspe ct for any pipe re str ict ions.
21 T rip le Evac uation Method The tr iple e va cua tion m et hod shoul d only be us ed when va cuum pump i s onl y capa ble of pumping down to 28 in. of mer cur y vac uum and s yste m does not c onta in any l iquid w at er . Refer to Fig . 37 and p roceed as follo ws: 1.
22 SER VICE ! W ARNING ELECTRICAL SHOCK HAZARD Fai lure to fol low thi s war ning coul d re sul t in pe rs onal inj ury or deat h. Befo re installin g, mo dify in g, or serv icing system , main electrical disco n nect switch m ust b e in th e OFF posi tion.
23 TROUBLES HOOTING See T abl e 12 and T abl e 13 for tr ouble shooti ng infor mati on. Fau lt Code Onc e a fa ilur e occur s with the i ndoor unit i n opera tion, t he gree n LED on the i ndoor unit f las hes a t inte rval s of 0.
24 Copyright 2009 Carrier Corp. S 7310 W . Morris St. S I ndianapolis, I N 46231 Prin ted in U.S .A. Edition Date: 09/09 Manufacturer reser ve s the right to change, at any time, specifications and de signs without notice and without ob ligations.
An important point after buying a device Carrier 40QNQ (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Carrier 40QNQ yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Carrier 40QNQ - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Carrier 40QNQ you will learn all the available features of the product, as well as information on its operation. The information that you get Carrier 40QNQ will certainly help you make a decision on the purchase.
If you already are a holder of Carrier 40QNQ, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Carrier 40QNQ.
However, one of the most important roles played by the user manual is to help in solving problems with Carrier 40QNQ. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Carrier 40QNQ along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center