7H02-06 F ast Ether net Smar tSWITCH ™ Interf ace Module User’ s Guide 9031924.
.
Notice i NO TICE Cabletron Systems r eserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made.
Notice ii FCC NO TICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference r eceived, including interference that may cause undesired operation.
Notice iii brouillage radioélectrique édicté par le ministèr e des Communications du Canada. VCCI NO TICE This equipment is in the 1st Class Category (information equipment to be used in commercia.
Notice iv EXCLUSION OF W ARRANTY AND DISCLAIMER OF LIABILITY 1. EXCLUSION OF W ARRANTY . Except as may be specifically provided by Cabletr on in writing, Cabletron makes no warranty , expressed or implied, concerning the Pr ogram (including Its documentation and media).
v CONTENTS CHAPTER 1 INTRODUCTION 1.1 USING THIS MANUAL ......................................................................... 1-1 1.2 THE 7H02-06 MODULE.......................................................................... 1-2 1.2.1 Cable T ype and FEPIMs .
vi Contents 5.3 SAFETY ...................................................................................................... 5-1 5.4 EMI ............................................................................................................. 5-1 5.
1-1 CHAPTER 1 INTRODUCTION W elcome to Cabletron Systems 7H02-06 Fast Ethernet SmartSwitch ™ Interface Module Installation Guide. This guide is a simple refer ence for installing and using the 7H02-06 Module. Before installing the module, car efully read this manual to gain a full understanding of its capabilities.
1-2 Introduction 1.2 THE 7H02-06 MODULE The 7H02-06 Module provides six Fast Ethernet ports via 5 RJ45 connectors and one FEPIM. The 7H02-06 Module can be installed in: • The 7C03 MMAC SmartSwitch .
Introduction 1-3 Figure 1-1. 7H02-06 Module 1.2.2 7C03 MMA C Smar tSwitch, the 7C04 W orkgr oup SmartSwitch and the 7C04-R W orkgroup SmartSwitch The 7H02-06 Module is designed to be installed in the 7C03 MMAC SmartSwitch, the 7C04 W orkgroup SmartSwitch or the 7C04-R W orkgroup SmartSwitch.
1-4 Introduction Ring to be used with the 7H02-06 Module. These modules provide the capability to share data without the use of external bridges or routers.
Introduction 1-5 1.3.2 FEPIMs The front panel connections ar e standard Cabletr on FEPIMs. Currently , the 7H02-06 supports the following two FEPIMs: • FE-100TX (see Figure 1-2). The FE-100TX allows Fast Ethernet connectivity using Category 5 T wisted Pair (UTP) cabling with one RJ45 connector .
1-6 Introduction 1.4 RELA TED MANU ALS The manuals listed below should be used to supplement the procedur es and other technical data provided in this manual.
2-1 CHAPTER 2 NETWORK REQUIREMENTS Before installing Cabletr on Systems 7H02-06 Module, review the network requir ements outlined in this chapter . All requir ements included in this chapter should be met to ensure satisfactory performance of the 7H02-06 Module.
2-2 Network Requirements Transmitter power parameters are listed in Table 2-2. The link distance is up to 2 kilometers on the multimode fiber-optic cable as specified by ANSI MMF-PMD. Note: The link distance for Full Duplex is 2km; if Full Duplex is not being utilized, the link distance is 400 meters.
Network Requirements 2-3 The link distance is up to 100 meters on unshielded Category 5 twisted pair cable as specified by ANSI TP-PMD. T able 2-3. FEPIM Pinouts Pin Number Represents Pin Number Repr.
2-4 Network Requirements.
3-1 CHAPTER 3 INSTALLATION This chapter contains instructions for unpacking and installing the 7H02-06 Module in the 7C03, 7C04, 7C04-R MMAC SmartSwitch. Also included in the chapter are instr uctions for the front panel FEPIMs. 3.1 UNP A CKING THE 7H02-06 MODULE Unpack the 7H02-06 Module by using the following steps: 1.
3-2 Installation Figure 3-1. Module Bottom View 3. Remove the blank front cover over the FEPIM slot. 4. Install the FEPIM as shown in Figure 3-2. Ensur e that the rear connector is seated firmly before tightening the thr ee mounting screws. Note: Carefully push the FEPIM straight down once it is firmly seated onto the module.
Installation 3-3 Figure 3-2. Installing an FEPIM 3.3 INST ALLING/REMO VING THE 7H02-06 MODULE The 7H02-06 Module is installed in: the 7C03 MMAC SmartSwitch, the 7C04 W orkgroup SmartSwitch or the 7C04-R W orkgroup SmartSwitch by using the following steps and referring to the appropriate figur e.
3-4 Installation 1. Remove the blank panel covering the slot in which the module will be installed. All other slots in the 7C03 must remain covered to ensur e proper airflow and cooling.
Installation 3-5 3.3.2 Removing the 7H02-06 Module fr om a 7C03 MMA C SmartSwitch T o remove the 7H02-06 Module fr om a 7C03 MMAC SmartSwitch, follow the listed steps and refer to Figur e 3-4. Note: Before removing the 7H02-06 Module, attach the wrist strap included with the module (instructions are printed on the packet).
3-6 Installation 3.3.3 Installing the 7H02-06 Module in a 7C04 or 7C04-R Chassis T o install the 7H02-06 Module in a 7C04 or 7C04-R Chassis, follow the listed steps and refer to Figur e 3-5 and Figure 3-6, r espectively . Notes: The 7H02-06 Module cannot be installed in the top slot of the 7C04 Chassis.
Installation 3-7 Figure 3-5. Installing the 7H02-06 Module in the 7C04 W orkgroup SmartSwitch Figure 3-6. Installing the 7H02-06 Module in the 7C04-R W orkgroup SmartSwitch 1 2 3 4 P S P S POWER IN PO.
3-8 Installation 3.3.4 Removing the 7H02-06 Module fr om a 7C04 or 7C04-R Chassis T o remove the 7H02-06 Module fr om a 7C04 or 7C04-R Chassis, follow the listed steps and refer to Figur e 3-7 and Figure 3-8 respectively .
Installation 3-9 Figure 3-8. Removing the 7H02-06 Module fr om the 7C04-R W orkgroup SmartSwitch. XXX -X XX- X XX XXX -X XX- X XX 4 3 2 1 Screws Ejector T abs.
3-10 Installation.
4-1 CHAPTER 4 T ROUBLESHOOTING The 7H02-06 Module uses LANVIEW , Cabletron Systems built-in visual diagnostic and status monitoring system. W ith LANVIEW LEDs the status of each transmit and receive port on the 7H02-06 Module can be determined, at a glance.
4-2 T roubleshooting T able 4-1 indicates the state of the receive port. T able 4-2 indicates the state of the transmit port. T able 4-1. Port Receive LEDs LED Color State Green Link, no activity , port enabled Green (Flashing) Link, port disabled Y ellow (Flashing) Link, activity , port enabled (flashing to steady-on indicates receive rate).
5-1 CHAPTER 5 T ECHNICAL SPECIFICATIONS This chapter includes the technical specifications for Cabletron Systems 7H02-06 module. Cabletron Systems r eserves the right to change these specifications at any time without notice.
5-2 T echnical Specifications • VCCI Class I 5.5 IMMUNITY The 7H02-06 Module meets the requir ements of EN50082-1 including: • IEC 801-2 ESD • IEC 803-1 radiated immunity • IEC 801-4 EFT/B 5.6 NETWORK INTERF A CES 5 RJ45 connectors and 1 FEPIM.
T echnical Specifications 5-3 5.8.3 En vironmental Operating T emperature +5 ° to +40 ° C (+41 ° to +104 ° F) Storage T emperature -30 ° to +80 ° C (-22 ° to +160 ° F) Relative Humidity 5 to .
5-4 T echnical Specifications.
A-1 APPENDIX A The 7H02-06 module uses Fast Ethernet Interface Modules (FEPIMs) to provide fr ont panel cable connections. The FEPIMs are user-installable. See the section ‘Installing an FEPIM’ on page 3-1. A.1 FE-100TX The FE-100TX is an RJ45 connector supporting Unshielded T wisted Pair (UTP) cabling.
A-2 Figure A-2. FE-100FX The transmitter power levels listed in T able A-1 are peak power levels after optical overshoot. A peak power meter must be used to correctly compar e the values given below to those measured on any particular port.
An important point after buying a device Cabletron Systems 7H02-06 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Cabletron Systems 7H02-06 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Cabletron Systems 7H02-06 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Cabletron Systems 7H02-06 you will learn all the available features of the product, as well as information on its operation. The information that you get Cabletron Systems 7H02-06 will certainly help you make a decision on the purchase.
If you already are a holder of Cabletron Systems 7H02-06, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Cabletron Systems 7H02-06.
However, one of the most important roles played by the user manual is to help in solving problems with Cabletron Systems 7H02-06. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Cabletron Systems 7H02-06 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center