EN
Bunn logo
Official user manual

Bunn ULTRA-2

23 pages·2.4 MB·Beverage Dispenser·PDF·ENDEFRITNLJA
Bunn ULTRA-2
Table of Contents 63 sections BUNN · ULTRA-2 · INSTALLATION & OPERATING MANUAL · BUNN-O-MATIC CORPORATION · … ShowHide
Page 1 of the Bunn ULTRA-2 user manual — www.bunnomatic.com
Page 1 · click to enlarge
Page 1

BUNN

®

ULTRA-2

Bunn ULTRA-2 — BUNN diagram (page 1)
Fig. 1

INSTALLATION & OPERATING MANUAL

BUNN-O-MATIC CORPORATION

POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644

www.bunnomatic.com

32080.0000 03/03 © 2002 Bunn-O-Matic Corporation

Page 3 of the Bunn ULTRA-2 user manual — SITE PREPARATION
Page 3 · click to enlarge
Page 3

USER NOTICES

Carefully read and follow all notices on the equipment and in this manual. They were written for your protec- tion. All notices are to be kept in good condition. Replace any unreadable or damaged labels.

Bunn ULTRA-2 — USER NOTICES diagram (page 3)
Fig. 2
Bunn ULTRA-2 — USER NOTICES diagram (page 3)
Fig. 3

CHARGE Type R404A, Amount 10 oz Design Pressures: High 240 Low 34

32162.0000 (ULTRA-2)

Bunn ULTRA-2 — 32162.0000 (ULTRA-2) diagram (page 3)
Fig. 4

27442.0000

CHARGE Type R404A, Amount 9.5 oz(269g) Design Pressures: High 215 Low 40

Bunn ULTRA-2 — 32162.0000 (ULTRA-2) diagram (page 3)
Fig. 5

DO NOT OVERLOAD CIRCUIT. ALWAYS ELECTRICALLY GROUND THE CHASSIS OR ADAPTOR PLUG. DO NOT DEFORM PLUG OR CORD. FOLLOW NATIONAL AND LOCAL ELECTRICAL CODES. KEEP COMBUSTIBLES AWAY.

29373.0000 (ULTRA-2A)

Risk of Electric Shock. This equipment may have two power supply cords. Unplug all cords before moving or servicing this equipment.

BEFORE USING THIS PRODUCT 00986.0002E 5/98 ©1994 Bunn-O-Matic Corporation

00986.0002

29947.0000

SITE PREPARATION

The dispenser is very heavy. Place it on a sturdy counter or shelf capable of supporting at least 180 lbs. It is for indoor use only.

The dispenser must have at least six inches of space behind it. This space is needed for airflow, air filter removal, and cleaning. A clearance of at approximately six inches is recommended between the dispenser sides and the wall or another appliance. The dispenser performs better if not placed near any heating appliance. Leave some space so the dispenser can be moved for cleaning.

ELECTRICAL REQUIREMENTS CAUTION – Improper electrical installation will damage components. An electrician must provide electrical service as specified below.

Model ULTRA-2, This dispenser has an attached cordset and requires a 2-wire, grounded, individual branch circuit rated 120 volts ac, 15 amp, single phase, 60 Hz. The mating connector must be a NEMA 5-15R. (Refer to the dataplate for exact electrical requirements.)

Model ULTRA-2A, This dispenser has an attached cordset and requires a 2-wire, grounded, individual branch circuit rated 230 volts ac, 10 amp, single phase, 50 Hz. (Refer to the dataplate for exact electrical requirements.)

32080 040802

Page 4 of the Bunn ULTRA-2 user manual — USER NOTICES
Page 4 · click to enlarge
Page 4

INITIAL SETUP CAUTION – The dispenser is very heavy! Use care when lifting or moving it. Use at least two people to lift or move the dispenser.

Bunn ULTRA-2 — USER NOTICES diagram (page 4)
Fig. 6
1. Set the dispenser on a sturdy counter top. The dispenser requires a minimum of 6.0" air clearance at the rear of the dispenser. For optimum performance, do not let warm air from surrounding machines blow on the ULTRA -2. NOTE – The dispenser should be level or slightly lower in front for proper operation.
2. Remove all shipping material, including the compressor support eyebolt, the cooling drum supports, the “Do Not Lift Here” signs from the cooling drums, and the “Rinse Before Using” signs from each hopper. For models without PAF (Powder Auto-Fill™), proceed to step #7.
Bunn ULTRA-2 — USER NOTICES diagram (page 4)
Fig. 7
3. Remove the rear plastic plug from the trim strip between the hopper drip trays and loosen the auger motor cover screws.
4. Place PAF platform assembly on top of the motor covers and install support rod into hole in trim strip.
5. Tighten support rod from top of platform. Retighten motor cover screws.
Bunn ULTRA-2 — USER NOTICES diagram (page 4)
Fig. 8
6. Plug RCA cord into ULTRA base unit. Proceed with steps 7 thru 12.
8. Press the seals firmly into place. 7. Install each hopper seal over the flange at the rear of the cooling drums as shown.

32080 021202

Page 5 of the Bunn ULTRA-2 user manual — INITIAL SETUP (CONT.)
Page 5 · click to enlarge
Page 5

INITIAL SETUP (CONT.)

9. Align the auger shaft with the flat fin of the auger. Push the augers as far as they will go and rotate them so the flat fin is facing up.
10. Install auger nose bushing into inside front of hopper.
11. Thoroughly rinse the hoppers and install them over the augers and cooling drums.
Bunn ULTRA-2 — INITIAL SETUP (CONT.) diagram (page 5)
Fig. 9
Bunn ULTRA-2 — INITIAL SETUP (CONT.) diagram (page 5)
Fig. 10
12. Slide them into place and push them down until the hopper lock plungers snap into place. For models without PAF, proceed to step 15.
13. For models with PAF, install level probes into slots at top rear of PAF hoppers.
14. Install PAF unit onto platform and plug power cord into rear of platform. Plug platform power cord into proper outlet. (Refer to PAF manual for water connections)(Proceed to step 17)
Bunn ULTRA-2 — INITIAL SETUP (CONT.) diagram (page 5)
Fig. 11
15. Set the lids on the hoppers. Lift slightly and slide back or front for filling.
16. Plug in the hopper lid lamp cords.
17. Assemble the drip tray.

32080 021202

Page 6 of the Bunn ULTRA-2 user manual — 2 3 4 5
Page 6 · click to enlarge
Page 6

OPERATING CONTROLS

There are five of these switches that will be used for the operation of the dispenser.

Bunn ULTRA-2 — OPERATING CONTROLS diagram (page 6)
Fig. 12

2 3 4 5

1. switch (upper left corner of the control pad)

This switch is the ON/OFF toggle switch which powers up the dispenser and the LCD display. When ON the Date and Time toggle back and forth continously except during programming.

2. (bottom left corner)

This is used to turn the left side auger motor ON or OFF.

3. (bottom left corner)

This is used to turn the left side ice control to OFF, ICE or CHILL.

4. (bottom right corner)

This is used to turn the right side auger motor ON or OFF.

5. (bottom right corner)

This is used to turn the right side ice control to OFF, ICE or CHILL.

32080 021202

Page 7 of the Bunn ULTRA-2 user manual — OPERATING CONTROLS
Page 7 · click to enlarge
Page 7

PROGRAMMING Using the menu-driven display on the front of the dispenser, the operator has the ability to alter or modify various parameters such as beverage consistency and set day/night “ON/OFF” times. The operator is also prompted to check a variety of periodic service functions or even a step-by-step cleaning routine. There is also the oppor- tunity to return all changes back to factory default settings.

Access to most controls can be password protected to allow only qualified personnel to make changes.

Bunn ULTRA-2 — OPERATING CONTROLS diagram (page 7)
Fig. 13

PROGRAMMING SWITCHES To access the programming mode, and to scroll through the different function screens, hidden programming switches are used. There are three of these switches that will be used for the setup of the dispenser.

1. I/O switch (upper left corner of the control pad) This switch is the ON/OFF toggle switch which powers up the dispenser and the LCD display. This switch is also used as back up switch in menu mode.
2. “GOURMET” (center under display) Press and hold this switch 5 seconds to access the Menu Function Index. This switch is also used as “NEXT” to scroll through the functions.
3. “ULTRA” (left under display) When prompted by a selection from the menu to answer yes or no, the “ULTRA” switch is used to answer “NO” or (-) minus.
4. “ICE” (right under display) When prompted by a selection from the menu to answer yes or no, the “ICE” switch is used to answer “YES” or (+) plus.

32080 021202

Page 8 of the Bunn ULTRA-2 user manual — JAN. 4, 2002 Off Off
Page 8 · click to enlarge
Page 8

PROGRAMMING THE DISPENSER

During normal operations, the Date, the Time, and the Serial Number toggle back and forth continuously. The following function screens are in the order they appear from the menu display. Each screen will have instructions and procedures to program the various functions of the dispenser.

HOME SCREEN Displays the TIME, DATE, SERIAL NUMBER and ASSET NUMBER which toggle back and forth continuously.

10:45:30 AM Off Off

JAN. 4, 2002 Off Off

ULT00000001 Off Off

AN00000001 Off Off

MENU FUNCTION INDEX Press and hold for five seconds the GOURMET hidden switch to enter into the Menu Function Index. The follow- ing screens are in order that they appear from the menu display. Pressing NO (“ULTRA”) or NEXT (GOURMET”) will advance to the next function. Press ON/OFF (“I/O”) will back up to the previous screen. A one minute time out will return to the Home Screen.

JAN. 4, 2002 Off Off

32080 032702

Page 9 of the Bunn ULTRA-2 user manual — STEP 7
Page 9 · click to enlarge
Page 9

This function leads the operator through a nine step cleaning process when answered YES (“ICE”). Depress GOURMET to display the next cleaning instruction.

When entering this mode, the refrigeration system will automatically turn OFF. After step when hoppers are drained, the augers will turn OFF. Three messages will display after advancing past the last cleaning instruction: FINISH/NEXT, PLEASE WAIT, ULTRA VERSION #

Bunn ULTRA-2 — STEP 1 diagram (page 9)
Fig. 14

STEP 1

STEP 2

STEP 3

Bunn ULTRA-2 — STEP 1 diagram (page 9)
Fig. 15

STEP 4

STEP 5

STEP 6

Bunn ULTRA-2 — STEP 4 diagram (page 9)
Fig. 16

STEP 7

STEP 8

STEP 9

Bunn ULTRA-2 — STEP 7 diagram (page 9)
Fig. 17

Cleaning Guide · 32080 021202

Page 10 of the Bunn ULTRA-2 user manual — SET THICKNESS ?
Page 10 · click to enlarge
Page 10

This function allows the operator to adjust the ice consistency, or torque of each auger when answered YES (“ICE”). Two screens will appear for left and right. The operator can scroll through a range of a minimum of1 (ULTRA) to a maximum of 16 (ICE). Factory default is 10.

SET THICKNESS ?

NO YES

MIN LEFT 9 MAX MIN RIGHT 5 MAX

Set Consistency · 32080 032702

Page 11 of the Bunn ULTRA-2 user manual — SET THICKNESS ?
Page 11 · click to enlarge
Page 11

This function tests the operation of forward and reverse of each auger motor. Left auger appears first. Press the ICE hidden switch to toggle between OFF, FORWARD and REVERSE. Press GOURMET hidden switch to repeat the operation for the right auger motor. A one minute time out will return to the Home Screen.

Bunn ULTRA-2 — SET THICKNESS ? diagram (page 11)
Fig. 18
Bunn ULTRA-2 — SET THICKNESS ? diagram (page 11)
Fig. 19

Select NEXT to repeat process for Right Auger Test.

Set Time and Date

Selecting YES (ICE) allows the operator to set the DATE (YY MM DD) and TIME (HR MIN SEC) for display on the Home Screen.

Bunn ULTRA-2 — SET THICKNESS ? diagram (page 11)
Fig. 20
Bunn ULTRA-2 — SET THICKNESS ? diagram (page 11)
Fig. 21

Test Augers · 32080 021202

Page 12 of the Bunn ULTRA-2 user manual — SET NIGHT TIME (-) OFF (+)
Page 12 · click to enlarge
Page 12

From this screen, the operator must know the password before moving on to the remaining functions. The range is from 0 - 9999 with the factory default being 0.

PASSWORD 0 (-) NEXT (+)

Set Night Time/Set Day Time

The setting of the Day/Night mode allows the dispenser to “power down” during off hours. The bottom corners displaying “ICE” will change to “CHILL” during the night mode. During the night mode, the product will be kept chilled to below 35°F. “ICE” reading will return after night mode elapses. With “OFF” representing 12:00 AM, the operator can scroll to the times desired for the night time mode to begin and end. (Some early models displayed the word “DISABLED” in place of the word “OFF”).

SET NIGHT TIME (-) OFF (+)

SET DAY TIME (-) OFF (+)

NIGHT TIME MODE CHILL CHILL

Password · 32080 022003

Page 13 of the Bunn ULTRA-2 user manual — PM COMPLETE ? NO YES
Page 13 · click to enlarge
Page 13

This feature allows the machine to defrost the product during day time operation. The defrost minutes setting will select the defrost time period. The freeze minutes setting will select the freeze time between defrost periods. These modes when activated will function anytime the machine is in day mode operation. The machine will automatically stay in the freeze mode for 2 hours after waking up from the night time mode. (This feature was not offered on some early models).

DEFROST MINUTES (-) OFF (+)

FREEZE MINUTES (-) 60 (+)

This function is used to reset a reminder message Preventive Maintenance Due every six months. The ma- chine will not shut down if service is not performed. When the service is performed and the message is answered YES (ICE), the time and date is recorded for another six months to elapse. This feature can be DISABLED by pressing (-) ULTRA hidden switch. (Some early models displayed the word “ENABLED” in place of the word “ON”).

PM COMPLETE ? NO YES

6 MONTH PM (-) ON (+)

Preventive Maintenance Complete? · 32080 022003

Page 14 of the Bunn ULTRA-2 user manual — NO THICK ADJUST
Page 14 · click to enlarge
Page 14

Day To Clean Off (formerly Days Disabled)

This function allows the operator to program a cleaning schedule from 1 to 14 days. The default screen is 0 or DISABLED. Selecting - or ULTRA will prompt the screen Days To Clean. Once a number of days is selected the screen will prompt two functions, CLEAN MESSAGE ONLY or CLEAN LOCKOUT. On the day selected, the display will toggle between DATE & TIME and CLEAN DUE TODAY. The dispenser will lock into night mode at midnight if “Clean Lockout” is activated. To reset the Clean Due Today message or lockout, two functions must be per- formed. Either power off the dispenser using the I/O (ON/OFF) switch and allow the barrels or cooling drums to warm over 50°F, or scroll to the Cleaning Guide and perform the cleaning service. The barrels will warm to over 50°F when cleaned with warm water and the message will disappear.

DAY TO CLEAN OFF

DAYS TO CLEAN 14

(-) NEXT (+)

(-) NEXT (+)

CLN MESSAGE ONLY

CLEAN LOCKOUT

(-) NEXT (+)

(-) NEXT (+)

This is an option of locking the Set Consistency function by selecting + (YES) or - (NO).

NO THICK ADJUST

YES THICK ADJUST

(-) NEXT (+)

(-) NEXT (+)

Consistency Adjust Lock · 32080 022003

Page 15 of the Bunn ULTRA-2 user manual — SET PASS WR 0
Page 15 · click to enlarge
Page 15

This function allows the operator to lockout the touch pad. Selecting + (ON) provides no time delay on switches except for the center (GOURMET) hidden switch. Selecting - (LOCKOUT) provides a five second hold to wake up the touch pad and a two minute time frame from last button pressed to make adjustments before returning to sleep mode (five second hold). (Some early models displayed the word “ENABLED” in place of the word “ON” and the word “DISABLED” in place of the word “LOCKOUT”).

SWITCHES (-) LOCKOUT (+)

SWITCHES (-) ON (+)

This is the function to set the password using a range of 0 to 9999 (the factory default is 0). When the password is set, the operator can only access the first four functions: Cleaning Guide, Set Consistency, Test Augers and Set Date & Time.

SET PASS WR 0

SET PASS WR 9999

(-) NEXT (+)

(-) NEXT (+)

Switches Enabled · Set Password · 32080 022003

Page 16 of the Bunn ULTRA-2 user manual — INSTALL DATE
Page 16 · click to enlarge
Page 16

Answering YES (ICE) to this function returns the unit back to preset factory constants. 1. Set Consistency ? 10 2. Set Night Time - DISABLED 3. Set Day Time - DISABLED 4. 6 Month PM - ENABLE 5. Days Disabled - DISABLED 6. Torque Adjust Lock - YES 7. Switches Enabled - ENABLED 8. Set Password - 0

RESTORE DEFAULT ?

NO YES

RESTORE DEFAULTS

ARE YOU SURE ? NO YES

The following three screens will scroll after advancing past the function “Restore Defaults”. The Install Date and Time is recorded when the dispenser is powered on for the first 100 hours. The Install Date and Time cannot be reset and is stored in permanent memory.

INSTALL DATE

3:55:25 AM ULTRA VERSION # __.__

NOV. 28, 2001

Restore Default? · Install Date · 32080 032702

Page 17 of the Bunn ULTRA-2 user manual — 0 0 36 36 ° 0 0 67 67 ° h
Page 17 · click to enlarge
Page 17

TEMP & TORQUE Press and hold for five seconds the ULTRA and ICE hidden switches to display the TEMP & TORQUE. The temperature of each cooling drum and the hot gas temperature will toggle back and forth. The auger torque is displayed continuously. Press and release the ULTRA and ICE hidden switches to return to HOME SCREEN. The TEMP & TORQUE mode is typically used for service.

Bunn ULTRA-2 — 0 0 36 36 ° 0 0 67 67 ° h diagram (page 17)
Fig. 22 · 0 0 36 36 ° 0 0 67 67 ° h

0 0 36 36 ° 0 0 67 67 ° h

CLEAN FILTER Monthly cleaning of the air filter is recommended. Should the air filter become dirty creating a high temperature problem, the unit will shut down until service is completed to correct the problem.

Bunn ULTRA-2 — 0 0 36 36 ° 0 0 67 67 ° h diagram (page 17)
Fig. 23 · 0 0 36 36 ° 0 0 67 67 ° h

32080 053102

Page 18 of the Bunn ULTRA-2 user manual — 0 0 36 36 ° 0 0 67 67 ° h
Page 18 · click to enlarge
Page 18

USING THE DISPENSER FOR GRANITA-TYPE PRODUCTS 1. Lift the lid slightly for the selected hopper and slide back to gain access to the hopper. 2. Place the pre-mixed liquid product in the selected hopper.

3. a. Press and release the (ON/OFF) switch to power on the dispenser.

b. Press and release the Left and/or Right (ON/OFF) switch to start the Auger Motor.

c. Press and release the (OFF/ICE/CHILL) switch and select ICE to begin the cooling process for the

selected hopper. 4. Wait for the liquid to freeze to the desired consistency.

The ice granules get too large and a consistent product is difficult to maintain if left frozen for an extended period of time. Set the NIGHT mode for a few hours each night and return it to the DAY mode when the product has thawed sufficiently. You’ll know it is in the NIGHT mode because the display will indicate NIGHT MODE.

USING THE DISPENSER FOR COLD LIQUID PRODUCTS 1. Lift the lid slightly for the selected hopper and slide back to gain access to the hopper. 2. Place the pre-mixed liquid product in the selected hopper.

3. a. Press and release the (ON/OFF) switch to power on the dispenser.

b. Press and release the Left and/or Right (ON/OFF) switch to start the Auger Motor.

c. Press and release the (OFF/ICE/CHILL) switch and select CHILL to begin the cooling process for

the selected hopper. 4. Wait for the liquid to cool.

32080 021202

Page 19 of the Bunn ULTRA-2 user manual — 0 0 36 36 ° 0 0 67 67 ° h
Page 19 · click to enlarge
Page 19

OTHER RECOMMENDATIONS FOR YOUR DISPENSER • Whether liquid concentrate or granulated powder, all product must be thoroughly mixed BEFORE adding it to the hoppers.

Bunn ULTRA-2 — 0 0 36 36 ° 0 0 67 67 ° h diagram (page 19)
Fig. 24 · 0 0 36 36 ° 0 0 67 67 ° h
  • For best results with granita-type products, use only products with an apparent brix of 12 or higher. Some products may work with an apparent brix as low as 9. Your experimentation with other products will be the best guide in this area.
  • Keep the pre-mixed liquid product refrigerated. This reduces cooling/freezing time in the dispenser.
  • Keep the hoppers topped-off during peak serving periods. Add pre-mixed liquid product as it is dispensed. This reduces the cooling/freezing time and assures you of always having product ready to dispense.
  • Keep the product level in the hoppers higher than the auger. Air will become entrapped in the mixture resulting in a clouded foamy consistency.
  • You may find it beneficial to turn down the ice controls to keep the ice granules from growing too large. Refer to Programming The Dispenser on page 11 for Setting the Consistency.
  • Some products freeze at a lower temperature than others. You may notice frost or ice on the hoppers. This is normal and should not be a concern.
  • Humidity in the air may cause sweating on the outside surfaces of the hoppers. This is to be expected and should not be a concern. The drip trays beneath the hoppers will capture this and cause it to flow to the lower drip tray for disposal.
  • Some noises are to be expected during normal operation of the dispenser. By becoming familiar with the noises made during normal operation, you will be better able to listen for problems.

32080 021202

Page 20 of the Bunn ULTRA-2 user manual — 0 0 36 36 ° 0 0 67 67 ° h
Page 20 · click to enlarge
Page 20

RECOMMENDED DAILY CLEANING NOTE – Turn the power OFF to the dispenser before proceeding. 1. Empty all product from the hoppers. Disconnect the hopper lid lamp cords and remove the lids.

Bunn ULTRA-2 — 0 0 36 36 ° 0 0 67 67 ° h diagram (page 20)
Fig. 25 · 0 0 36 36 ° 0 0 67 67 ° h
2. Depress the hopper lock plunger. Lift the hopper up slightly.
5. Remove the cooling drum seal from the rear of the drum.
6. Caution: The faucet valve is under spring tension. Spread one side of the handle first, then the other and disconnect from the hopper.
7. Carefully slide the faucet valve up to remove the spring and faucet seal. Extra care should be taken when handling the seal to prevent damage. Do not fold the seal as this will cause damage to the Teflon ® sealing surface.
8. Remove the auger nose bushing from inside the hopper.
9. Care must be taken to ensure this surface does not get scratched during cleaning. Deep scratches could cause leakage around the seal.

10. Place all parts in a clean sink with mild hot water (120°F) and sanitizer solution. Allow all parts to soak for at least 5 minutes. Carefully wash all components with a clean wash cloth in the hot water and sanitizer solution. Use a clean, soft bristle brush as needed for the smaller components and tight areas. Do not immerse hopper lids. Use a commercial sanitizer that has 100 ppm of available chlorine with a concentration level of at least 3% available chlorine (KAY-5 Sanitizer). Follow the sanitizer’s mixing instructions to ensure 100 ppm of available chlorine. 11. Wash the drums, hopper drip trays, top covers, and outer enclosure using a clean wash cloth that has been dampened in the hot water and sanitizer solution. Pay particular attention to the shaft area and make sure it is thoroughly cleaned and sanitized. 12. Thoroughly rinse all surfaces with a clean wash cloth that has been dampened with hot water. Wipe dry with a clean dry wash cloth before reassembling the dispenser. NOTE – Although most parts are dishwasher safe, they may be affected by the chemicals in some commercial sanitizing agents. Do not place the hopper nor hopper lids in a dishwasher. Rinse thoroughly before assembly.

32080 032702

Page 21 of the Bunn ULTRA-2 user manual — INSTALLATION
Page 21 · click to enlarge
Page 21

INSTALLATION

Bunn ULTRA-2 — INSTALLATION diagram (page 21)
Fig. 26
1. Install the seals over the flange at the rear of the cooling drums and press the seals firmly into place as shown.
2. Align the auger shafts with the augers. Push the augers as far as they will go and rotate them so the flat face of the auger shaft is aligned with the flat face of the auger nose.
3. Install auger nose bushing into inside front of hopper.
Bunn ULTRA-2 — INSTALLATION diagram (page 21)
Fig. 27
4. Thoroughly rinse the hoppers and install them over the augers and cooling drums.
5. Slide them into place and push them down until the hopper lock plungers snap into place.
6. Set the lids on the hoppers and plug in the hopper lid lamp cords.
7. Position the faucet seal and return spring in the faucet valve.
8. Slide the faucet valve assembly into place on the hopper.
9. Press down on the valve to compress the spring. Position the faucet handle over the faucet valve one side at a time and snap into place on the hopper.

32080 053102

Page 22 of the Bunn ULTRA-2 user manual — SCHEMATIC WIRING DIAGRAM ULTRA-2
Page 22 · click to enlarge
Page 22

SCHEMATIC WIRING DIAGRAM ULTRA-2

RIGHT

N L GRN

Bunn ULTRA-2 — SCHEMATIC WIRING DIAGRAM ULTRA-2 diagram (page 22)
Fig. 28

BLK-22 ORN-22 YEL-22 GRN-22 BLU-22 VIO-22 GRY-22 WHI-22 TAN-22 PNK-22 WHI/BLK-22

32080 021502

Page 23 of the Bunn ULTRA-2 user manual — SCHEMATIC WIRING DIAGRAM ULTRA-2A
Page 23 · click to enlarge
Page 23

SCHEMATIC WIRING DIAGRAM ULTRA-2A

N L GND

Bunn ULTRA-2 — SCHEMATIC WIRING DIAGRAM ULTRA-2A diagram (page 23)
Fig. 29

BLK-22 ORN-22 YEL-22 GRN-22 BLU-22 VIO-22 GRY-22 WHI-22 TAN-22 PNK-22 WHI/BLK-22

32080 053102

Ask about the Bunn ULTRA-2

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Bunn ULTRA-2

Be the first to ask — other owners or our team will answer.

Original document

Bunn ULTRA-2 manual PDF

23 pages·2.4 MB·Beverage Dispenser·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…