ULTRA-2

POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644
32080.0000 03/03 © 2002 Bunn-O-Matic Corporation


Carefully read and follow all notices on the equipment and in this manual. They were written for your protec- tion. All notices are to be kept in good condition. Replace any unreadable or damaged labels.


CHARGE Type R404A, Amount 10 oz Design Pressures: High 240 Low 34

27442.0000
CHARGE Type R404A, Amount 9.5 oz(269g) Design Pressures: High 215 Low 40

DO NOT OVERLOAD CIRCUIT. ALWAYS ELECTRICALLY GROUND THE CHASSIS OR ADAPTOR PLUG. DO NOT DEFORM PLUG OR CORD. FOLLOW NATIONAL AND LOCAL ELECTRICAL CODES. KEEP COMBUSTIBLES AWAY.
Risk of Electric Shock. This equipment may have two power supply cords. Unplug all cords before moving or servicing this equipment.
BEFORE USING THIS PRODUCT 00986.0002E 5/98 ©1994 Bunn-O-Matic Corporation
00986.0002
29947.0000
The dispenser is very heavy. Place it on a sturdy counter or shelf capable of supporting at least 180 lbs. It is for indoor use only.
The dispenser must have at least six inches of space behind it. This space is needed for airflow, air filter removal, and cleaning. A clearance of at approximately six inches is recommended between the dispenser sides and the wall or another appliance. The dispenser performs better if not placed near any heating appliance. Leave some space so the dispenser can be moved for cleaning.
ELECTRICAL REQUIREMENTS CAUTION – Improper electrical installation will damage components. An electrician must provide electrical service as specified below.
Model ULTRA-2, This dispenser has an attached cordset and requires a 2-wire, grounded, individual branch circuit rated 120 volts ac, 15 amp, single phase, 60 Hz. The mating connector must be a NEMA 5-15R. (Refer to the dataplate for exact electrical requirements.)
Model ULTRA-2A, This dispenser has an attached cordset and requires a 2-wire, grounded, individual branch circuit rated 230 volts ac, 10 amp, single phase, 50 Hz. (Refer to the dataplate for exact electrical requirements.)
32080 040802

INITIAL SETUP CAUTION – The dispenser is very heavy! Use care when lifting or moving it. Use at least two people to lift or move the dispenser.



32080 021202




32080 021202

There are five of these switches that will be used for the operation of the dispenser.

This switch is the ON/OFF toggle switch which powers up the dispenser and the LCD display. When ON the Date and Time toggle back and forth continously except during programming.
This is used to turn the left side auger motor ON or OFF.
This is used to turn the left side ice control to OFF, ICE or CHILL.
This is used to turn the right side auger motor ON or OFF.
This is used to turn the right side ice control to OFF, ICE or CHILL.
32080 021202

PROGRAMMING Using the menu-driven display on the front of the dispenser, the operator has the ability to alter or modify various parameters such as beverage consistency and set day/night “ON/OFF” times. The operator is also prompted to check a variety of periodic service functions or even a step-by-step cleaning routine. There is also the oppor- tunity to return all changes back to factory default settings.
Access to most controls can be password protected to allow only qualified personnel to make changes.

PROGRAMMING SWITCHES To access the programming mode, and to scroll through the different function screens, hidden programming switches are used. There are three of these switches that will be used for the setup of the dispenser.
32080 021202

During normal operations, the Date, the Time, and the Serial Number toggle back and forth continuously. The following function screens are in the order they appear from the menu display. Each screen will have instructions and procedures to program the various functions of the dispenser.
HOME SCREEN Displays the TIME, DATE, SERIAL NUMBER and ASSET NUMBER which toggle back and forth continuously.
JAN. 4, 2002 Off Off
ULT00000001 Off Off
AN00000001 Off Off
MENU FUNCTION INDEX Press and hold for five seconds the GOURMET hidden switch to enter into the Menu Function Index. The follow- ing screens are in order that they appear from the menu display. Pressing NO (“ULTRA”) or NEXT (GOURMET”) will advance to the next function. Press ON/OFF (“I/O”) will back up to the previous screen. A one minute time out will return to the Home Screen.
32080 032702

This function leads the operator through a nine step cleaning process when answered YES (“ICE”). Depress GOURMET to display the next cleaning instruction.
When entering this mode, the refrigeration system will automatically turn OFF. After step when hoppers are drained, the augers will turn OFF. Three messages will display after advancing past the last cleaning instruction: FINISH/NEXT, PLEASE WAIT, ULTRA VERSION #

STEP 2
STEP 3

STEP 5
STEP 6

STEP 8
STEP 9

Cleaning Guide · 32080 021202

This function allows the operator to adjust the ice consistency, or torque of each auger when answered YES (“ICE”). Two screens will appear for left and right. The operator can scroll through a range of a minimum of1 (ULTRA) to a maximum of 16 (ICE). Factory default is 10.
NO YES
MIN LEFT 9 MAX MIN RIGHT 5 MAX
Set Consistency · 32080 032702

This function tests the operation of forward and reverse of each auger motor. Left auger appears first. Press the ICE hidden switch to toggle between OFF, FORWARD and REVERSE. Press GOURMET hidden switch to repeat the operation for the right auger motor. A one minute time out will return to the Home Screen.


Select NEXT to repeat process for Right Auger Test.
Set Time and Date
Selecting YES (ICE) allows the operator to set the DATE (YY MM DD) and TIME (HR MIN SEC) for display on the Home Screen.


Test Augers · 32080 021202

From this screen, the operator must know the password before moving on to the remaining functions. The range is from 0 - 9999 with the factory default being 0.
Set Night Time/Set Day Time
The setting of the Day/Night mode allows the dispenser to “power down” during off hours. The bottom corners displaying “ICE” will change to “CHILL” during the night mode. During the night mode, the product will be kept chilled to below 35°F. “ICE” reading will return after night mode elapses. With “OFF” representing 12:00 AM, the operator can scroll to the times desired for the night time mode to begin and end. (Some early models displayed the word “DISABLED” in place of the word “OFF”).
SET DAY TIME (-) OFF (+)
NIGHT TIME MODE CHILL CHILL
Password · 32080 022003

This feature allows the machine to defrost the product during day time operation. The defrost minutes setting will select the defrost time period. The freeze minutes setting will select the freeze time between defrost periods. These modes when activated will function anytime the machine is in day mode operation. The machine will automatically stay in the freeze mode for 2 hours after waking up from the night time mode. (This feature was not offered on some early models).
FREEZE MINUTES (-) 60 (+)
This function is used to reset a reminder message Preventive Maintenance Due every six months. The ma- chine will not shut down if service is not performed. When the service is performed and the message is answered YES (ICE), the time and date is recorded for another six months to elapse. This feature can be DISABLED by pressing (-) ULTRA hidden switch. (Some early models displayed the word “ENABLED” in place of the word “ON”).
6 MONTH PM (-) ON (+)
Preventive Maintenance Complete? · 32080 022003

Day To Clean Off (formerly Days Disabled)
This function allows the operator to program a cleaning schedule from 1 to 14 days. The default screen is 0 or DISABLED. Selecting - or ULTRA will prompt the screen Days To Clean. Once a number of days is selected the screen will prompt two functions, CLEAN MESSAGE ONLY or CLEAN LOCKOUT. On the day selected, the display will toggle between DATE & TIME and CLEAN DUE TODAY. The dispenser will lock into night mode at midnight if “Clean Lockout” is activated. To reset the Clean Due Today message or lockout, two functions must be per- formed. Either power off the dispenser using the I/O (ON/OFF) switch and allow the barrels or cooling drums to warm over 50°F, or scroll to the Cleaning Guide and perform the cleaning service. The barrels will warm to over 50°F when cleaned with warm water and the message will disappear.
DAYS TO CLEAN 14
(-) NEXT (+)
(-) NEXT (+)
CLN MESSAGE ONLY
CLEAN LOCKOUT
(-) NEXT (+)
(-) NEXT (+)
This is an option of locking the Set Consistency function by selecting + (YES) or - (NO).
YES THICK ADJUST
(-) NEXT (+)
(-) NEXT (+)
Consistency Adjust Lock · 32080 022003

This function allows the operator to lockout the touch pad. Selecting + (ON) provides no time delay on switches except for the center (GOURMET) hidden switch. Selecting - (LOCKOUT) provides a five second hold to wake up the touch pad and a two minute time frame from last button pressed to make adjustments before returning to sleep mode (five second hold). (Some early models displayed the word “ENABLED” in place of the word “ON” and the word “DISABLED” in place of the word “LOCKOUT”).
SWITCHES (-) ON (+)
This is the function to set the password using a range of 0 to 9999 (the factory default is 0). When the password is set, the operator can only access the first four functions: Cleaning Guide, Set Consistency, Test Augers and Set Date & Time.
SET PASS WR 9999
(-) NEXT (+)
(-) NEXT (+)
Switches Enabled · Set Password · 32080 022003

Answering YES (ICE) to this function returns the unit back to preset factory constants. 1. Set Consistency ? 10 2. Set Night Time - DISABLED 3. Set Day Time - DISABLED 4. 6 Month PM - ENABLE 5. Days Disabled - DISABLED 6. Torque Adjust Lock - YES 7. Switches Enabled - ENABLED 8. Set Password - 0
NO YES
RESTORE DEFAULTS
ARE YOU SURE ? NO YES
The following three screens will scroll after advancing past the function “Restore Defaults”. The Install Date and Time is recorded when the dispenser is powered on for the first 100 hours. The Install Date and Time cannot be reset and is stored in permanent memory.
3:55:25 AM ULTRA VERSION # __.__
NOV. 28, 2001
Restore Default? · Install Date · 32080 032702

TEMP & TORQUE Press and hold for five seconds the ULTRA and ICE hidden switches to display the TEMP & TORQUE. The temperature of each cooling drum and the hot gas temperature will toggle back and forth. The auger torque is displayed continuously. Press and release the ULTRA and ICE hidden switches to return to HOME SCREEN. The TEMP & TORQUE mode is typically used for service.

CLEAN FILTER Monthly cleaning of the air filter is recommended. Should the air filter become dirty creating a high temperature problem, the unit will shut down until service is completed to correct the problem.

32080 053102

USING THE DISPENSER FOR GRANITA-TYPE PRODUCTS 1. Lift the lid slightly for the selected hopper and slide back to gain access to the hopper. 2. Place the pre-mixed liquid product in the selected hopper.
b. Press and release the Left and/or Right (ON/OFF) switch to start the Auger Motor.
c. Press and release the (OFF/ICE/CHILL) switch and select ICE to begin the cooling process for the
selected hopper. 4. Wait for the liquid to freeze to the desired consistency.
The ice granules get too large and a consistent product is difficult to maintain if left frozen for an extended period of time. Set the NIGHT mode for a few hours each night and return it to the DAY mode when the product has thawed sufficiently. You’ll know it is in the NIGHT mode because the display will indicate NIGHT MODE.
USING THE DISPENSER FOR COLD LIQUID PRODUCTS 1. Lift the lid slightly for the selected hopper and slide back to gain access to the hopper. 2. Place the pre-mixed liquid product in the selected hopper.
b. Press and release the Left and/or Right (ON/OFF) switch to start the Auger Motor.
c. Press and release the (OFF/ICE/CHILL) switch and select CHILL to begin the cooling process for
the selected hopper. 4. Wait for the liquid to cool.
32080 021202

OTHER RECOMMENDATIONS FOR YOUR DISPENSER • Whether liquid concentrate or granulated powder, all product must be thoroughly mixed BEFORE adding it to the hoppers.

32080 021202

RECOMMENDED DAILY CLEANING NOTE – Turn the power OFF to the dispenser before proceeding. 1. Empty all product from the hoppers. Disconnect the hopper lid lamp cords and remove the lids.

10. Place all parts in a clean sink with mild hot water (120°F) and sanitizer solution. Allow all parts to soak for at least 5 minutes. Carefully wash all components with a clean wash cloth in the hot water and sanitizer solution. Use a clean, soft bristle brush as needed for the smaller components and tight areas. Do not immerse hopper lids. Use a commercial sanitizer that has 100 ppm of available chlorine with a concentration level of at least 3% available chlorine (KAY-5 Sanitizer). Follow the sanitizer’s mixing instructions to ensure 100 ppm of available chlorine. 11. Wash the drums, hopper drip trays, top covers, and outer enclosure using a clean wash cloth that has been dampened in the hot water and sanitizer solution. Pay particular attention to the shaft area and make sure it is thoroughly cleaned and sanitized. 12. Thoroughly rinse all surfaces with a clean wash cloth that has been dampened with hot water. Wipe dry with a clean dry wash cloth before reassembling the dispenser. NOTE – Although most parts are dishwasher safe, they may be affected by the chemicals in some commercial sanitizing agents. Do not place the hopper nor hopper lids in a dishwasher. Rinse thoroughly before assembly.
32080 032702



32080 053102

RIGHT
N L GRN

BLK-22 ORN-22 YEL-22 GRN-22 BLU-22 VIO-22 GRY-22 WHI-22 TAN-22 PNK-22 WHI/BLK-22
32080 021502

N L GND

BLK-22 ORN-22 YEL-22 GRN-22 BLU-22 VIO-22 GRY-22 WHI-22 TAN-22 PNK-22 WHI/BLK-22
32080 053102
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.