To obtain the Illustrated Parts Catalog, visit the Bunn-O-Matic website, at www.bunn.com This is absolutely FREE, and the quickest way to obtain the catalog. Contact Bunn-O-Matic Corporation at 1-800-286-6070 to obtain a paper copy of the required Illustrated Parts Catalog mailed via U.S. Postal Service.
www.bunnomatic.com 34766.0000J 01/07 ©2002 Bunn-O-Matic Corporation


INTRODUCTION The Liquid Coffee Ambient Dispenser (LCA-2) and the Liquid Coffee Chilled Dispenser (LCC-2) delivers two types of coffee plus hot water. The dispenser can be set up for continuous draw (by the cup) for self-serve ap plications, or portion-control to fill carafes and decanters for wait staff. Product Flavor Profile is extended with chilled product storage cabinet featured in the LCC-2.
Carefully read and follow all notices on the equipment and in this manual. They were written for your protec tion. All notices are to be kept in good condition. Replace any unreadable or damaged labels.


This equipment must be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA). For models installed outside the U.S.A., comply with the applicable Plumbing /SanitationCode.
00656.0000
00986.0002


To reduce the risk of electric shock, do not remove or open cover. No user-serviceable parts inside. Authorized service personnel only. Disconnect power before servicing.
208-240 V, 25.8 A, 6200 W 1PH, 2-Wire + GND, 60HZ or 120/208-240 V, 25.8 A, 6200 W 1PH, 3-Wire + GND, 60HZ
37881.0000
28181.0003
11646.0002
· 34766 010407

Up.
The LCA-2 and LCC-2 dispensers are supplied with a 120-volt / 15 Amp cord set and require a 2-wire, grounded, individual branch circuit rated for 120 volts AC, 15 amp, single phase, 60Hz. The mating connector must be a NEMA 5-15R. The LCA-2C and LCC-2C dispensers are supplied with a 120-volt / 20 Amp cord set and require a 2-wire, grounded, individual branch circuit rated for 120 volts AC, 20 amp, single phase, 60Hz. The mating connector must be a NEMA 5-20R. These dispensers can be Field Wired for 208 or 240 volt applications. This requires a 2 or 3-wire, grounded, individual branch circuit rated for 208/240 volts AC, 30 amp, single phase, 60 Hz.
Models without Master ON/OFF Switch

LIMIT SW. - BLACK For all 208 - 240 Volt Connections: Use No. 10 AWG Wires suitable for 90°C (194 °F) 1. Unit shipped per Fig. 1, wired for 120V A.C./2-Wire. 2. For 208 - 240V A.C./2-Wire per Fig. 2: Move both the Red-Heater wire and the White-Fuse wire to the Top Red Terminal as shown. 3. For 120/208 - 240V A.C./3-Wire per Fig. 3: Move the Red Heater wire to the Top Red Terminal as shown.
Models with Master ON/OFF Switch
ON/OFF SWITCH
BLACK
For all 208 - 240 Volt Connections: Use No. 10 AWG Wires suitable for 90°C (194°F) 1. Unit shipped per Fig. 1, wired for 120V A.C./2-Wire. 2. For 208 - 240V A.C./2-Wire per Fig. 2. 3. For 120/208 - 240V A.C./3-Wire per Fig. 3.
· 34766 010407

The dispenser may be connected to a cold or hot water system (140°F Max.) with operating pressure between 20 and 90 psi (138 and 620 kPa) from a 1/2” or larger supply line. A shut-off valve should be installed in the line before the dispenser. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The water inlet fitting is 3/8” flare. Dispensers set up to deliver to 1.8 Oz./sec. (53.2 ml/sec) per dispense tip, require a water supply source that can deliver a minimum of 1.7 gpm (6.4 lpm) at the inlet fitting. Dispensers set up to deliver 2.6 Oz./sec. (76.9 lpm) per dispense tip, require a water supply source that can deliver a minimum of 2.4 gpm (9.2 lpm) at the inlet fitting. NOTE: Bunn-O-Matic recommends 3/8” tubing from the 1/2” water supply line. At least 18 inches of FDA approved flexible beverage tubing, such as reinforced braided polyethylene or silicone, before the dispenser will facilitate movement to clean the counter top. Bunn-O-Matic does not recommend the use of a saddle valve to install the dispenser. The size and shape of the hole made in the supply line by this type of device may restrict water flow.
This equipment must be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA). For models installed outside the U.S., you must comply with the applicable Plumbing/Sanitation Code for your area.
1. Locate and remove the information packets and tube kits from top of packaging and set aside. 2. Remove foam packing and cut around the bottom of box. 3. Remove the box and the rest of the foam packing. 4. Open the dispenser door and remove the drip tray and the lower splash guard panel. 5. Set dispenser on the counter where it is to be used. CAUTION: DO NOT LIFT ON THE DOOR. 6. Confirm the dispenser is level on the counter.
· 34766 010407

The dispenser comes from the factory with flow restrictors in the mix chambers. With the restrictors in place the dispense rate is about 1.8 oz./sec (53.2 ml/sec) and is used primarily for cup at a time dispensing. The flow restrictors can be removed to increase the dispense rate to about 2.5 oz./sec (74 ml/sec) for larger volume dispensing (airpots, carafes, etc.). NOTE: The hot water FlowRate is fixed at approximately 1.7 oz/sec. and can not be adjusted.
Removing the restrictors: 1. Disconnect the dispenser from the AC power source. 2. Open the Product Cabinet door. 3. Remove the concentrate tube, vent line and grommet from mix chamber ports in side the product cabinet. 4. Remove the two screws that fasten mix chamber to the control panel. 5. Gently pull mix chamber away from dispenser to expose water line connection, (you may have to rotate it slightly). 6. Disconnect FlavorGard™ sensor wire and hot water tubing from the mix chamber. 7. Remove the flow restrictor from the inlet to the mix chamber. 8. Reconnect FlavorGard™ sensor wire and hot water tubing to the mix chamber. 9. Place mix chamber back into position in the dispenser, (you may have to rotate it slightly) and secure it with the two screws 10. Reposition the grommet, vent line and pump tubing onto the mix chamber ports. Caution: Failure to properly replace and secure any of the above components may result leaks and/or cause damage to the dispenser.
If you changed the Dispenser Flow Rate, you will need to reprogram the dispenser to the new rate, see Programming the Dispenser. CAUTION: Failure to reprogram the Dispenser Flow Rates will result in inaccurate Mix Ratios.
Reprogramming the Dispenser Flow Rate: 1. Remove the lower splash guard panel and locate the Programming module. 2. Use the Down Arrow key to enter into the programming function and scroll through the menu’s to the “CAL LEFT SIDE?” menu and select “YES”. 3. Scroll down to the “CAL LF WTR VOL” menu 4. Use the (+) & (-) keys to enter a volume of 50 Oz. (1478 mL). This will recalibrate the Left dispenser to the new rate. 5. Scroll down to the “CAL RT WTR VOL” menu 6. Use the (+) & (-) keys to enter a volume of 50 Oz. (1478 mL). This will recalibrate the Right dispenser to the new rate. 7. Select “Exit” to leave the programming menu. Note: The default volume of 50 Oz (1478 mL), is the typical Cal Volume for a 2.5 Oz/sec Flow Rate Test, see Field Calibration of the Concentrate Pumps / Dispenser Flow Rates.
· 34766 120105

There are two pump tube sizes available for use with this dispenser. To determine the correct tubing for you application, first determine the dispenser flow rate you intend to use, refer to Setting Dispenser Flow Rate. Then look up the recommended tube size for the mix ratio of your concentrate, refer to the Tube Selection Chart.
TUBE SELECTION CHART Dispense Concentrate Ratios Rate 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 1.8 Oz/sec. 3/16” I.D. TUBING 1/8” I.D. TUBING (53 ml/sec.) 2.5 Oz/sec. 3/16” I.D. TUBING 1/8” I.D. TUBING (74 ml/sec.)
Examples:
Tube kits can be purchased from BUNN-O-MATIC. Part # 34727.1000 for 3/16” I.D. Tubing or #34728.1000 for 1/8” I.D. Tubing.
INSTALLING THE PUMP TUBING (Refer to the Tubing Installation Instructions in side the cabinet door for details.) 1. Loosen the thumbscrew securing the tubing retainer plate to the pump housing. Set it and the retainer plate aside. 2. Depress the tension screw and remove it from the notch in the pump body, releasing the spring tension on the pump band. 3. Apply lubricant (BUNN-O-MATIC part number M2531.0001) to the new pump tubing. 4. Insert the tubing onto the mix chamber port and wrap the tubing around the pump rotor, making sure that the elbow and clamps end up on the bottom side of the pump body. 5. Close the compression band reinsert the tension screw into the notch in the pump housing. 6. Replace the tubing retainer plate and tighten the thumbscrew. 7. Reconnect bag connector to the product box. 8. Repeat steps 1 through 7 for the other pump. 9. Prime the pumps. Refer to Priming the Concentrate Lines section.




2.0” 2.0” Tension Screw
Remove Retaining Plate Release Spring Tension Remove Tubing Lubricate New Tube


Install New Tubing Completed Installation

1a. Dispense Handles: Pull and Hold to dispense product. 1b. Dispense Switches: Push and Release to dispense product for Portion Control Models. 2. Stop Switch: Momentary switch stops all dispense functions. 3a. Hot Water Switch: Push and Hold switch to dispense hot water from the center dispense tip. 3b. Push and Release switch for Portion Control Models. 4. Alternate Portion Control Switch: Momentarily pushed to select the Alternate Portion Control Volume #2. 5. Function Selector Switch: Allows the user to set the dispenser into different dispensing modes. a. Rinse: Dispenses hot water only- Flushes the mix chamber and dispense tip. b. Prime: Dispenses concentrates only – Primes the concentrate pump. c. Normal: Normal dispense mode - Dispenses mixed product (concentrate and water). 6. Mode Selector Switch: Allows the user to set the dispenser into different operating modes. a. Run: Normal operating position. b. Off: Turns off all functions including tank heater and chiller. WARNING - The OFF Mode does not remove AC power from the dispenser. Disconnect power source before servicing the dispenser
operational. 7. Door Interlock Switch: Unit will not dispense product if the door is open. 8. Power LED: Red - illuminates when AC power is applied to dispenser. 9. Ready LED: Green - illuminates when the water is at the preset ready temperature. 10. Portion LED: Yellow - illuminates when the portion dispense option has been selected, (5 second delay). 11. Rinse LED: Yellow - illuminates when the optional preset rinse alarm time has elapsed. 12. Left Refill LED: Yellow - illuminates when the Left Concentrate BIB needs replaced. 13. Right Refill LED: Yellow - illuminates when the Right Concentrate BIB needs replaced. 14. Programming Keypad: Used in conjunction with the LCD display to program and calibrate the dispenser to customer specific requirements. (Located behind the splash guard panel) 15. LCD Display: Displays programming menus and fault messages. (Located behind the splash guard panel)


AMBIENT UNIT
12 15 14 · · 34766 120105

1. Select Normal on the Function Selector Switch and Run on the Mode Selector Switch. 2. Confirm the water supply is on. 3. Connect the dispenser to the power source. The Red POWER LED will illuminate and water will begin flowing into the tank. The dispenser will automatically stop filling when the tank is full. The dispenser will not begin heating the water until after the tank is filled. Dispenser models with product chillers will begin to cool the cabinet at this time. 4. The Green READY LED will illuminate when the tank temperature reaches the preset ready temperature. Note: The time required to heat the water initially will vary depending on the AC Power supplied to the dispenser.
While the tank is heating, the dispenser may be readied for use as described in Programming Functions & Basic

· 34766 112502

FlavorGard™ is a patented feed back control loop that monitors the mixed product and adjusts the concentrate delivery rate to maintain a consistent mix profile, i.e. Flavor Profile. The system consists of a conductance probe mounted in the final stages of the mixing chamber, a metering pump with RPM sensor and a digital controller. Once you have completed the installation of the dispenser, entered the desired mix ratio for your concentrate, dispensed several cups of the mixed product, and are satisfied with the Flavor and Strength being delivered, simply enable FlavorGard™, (refer to FlavorGard™ in Programming the Dispenser).
The dispenser will automatically calibrate the system to all the factors that make up your particular mix profile, (e.g. water source, filtration system, Brand of concentrate and mix ratio selected, etc.). NOTE: It is very important that you have dispensed enough product to insure that the dispenser is fully functional and you are satisfied with the Flavor Profile of the mix product before enabling FlavorGard™.
Once FlavorGard™ is enabled, the dispenser will continuously monitor the mix product as it is being dispensed and adjust the metering pump speed to maintain a consistent mixed product, thus eliminating factors such as (settling of the concentrate, tube wear, viscosity changes, liming, etc.).
The system is designed to work with in the range of variations that can be caused by these factors. The factory preset range is (+/- 10 %) and is adjustable to a Max of (+/- 15%). This insures that the FlavorGard™ system is not responding to factors that cannot be corrected by minor adjustments to the speed of the metering pump, (e.g. kinked hoses, low water pressure, severely worn tubes, empty BIB’s, etc). NOTE: Changes to Concentrate Ratios or Dispenser Flow Rates will automatically disable FlavorGard™. You will need to re-enable FlavorGard™, once you are satisfied with the new Flavor Profile.
Periodic rinsing of the mix chambers and dispense tips is essential for proper maintenance and optimum performance of the dispenser. The automated Rinse Alarm feature has three levels of operation, Disabled, Warning Only and Warning with Brew Lockout, see chart for details.
Alarm Level Selected Alarm Mode Disabled None Warning Only Rinse LED will come on 4 hrs prior to the selected time interval and remain on until the Rinse procedure has been performed. The dispenser will continue to serve product. Warning w/ Brew Lockout Rinse LED will come on 4 hrs prior to the selected time interval and remain on until the Rinse procedure has been performed. The dispenser will Lockout and not continue to serve product once the selected time interval has elapsed. NOTE: The time interval between Rinses is adjustable from 8 to 24 hrs.
The dispenser is shipped with the automated Rinse Alarm disabled, (No Alarm). It is up to the user to determine the Rinse time interval and the level of warning required, based on their application and maintenance procedures. To enable the automated Rinse Alarm feature, refer to RINSE ALARM ? in Programming the Dispenser.
34766 050103

Rinse Procedure:
1. Open the cabinet door and select Rinse on the Function Selector switch – close the door. 2. Place a 2 Liter (1/2 Gal) container under the Left dispense tip. 3. Activate the Left dispenser until water flow stops automatically, approximately 20 sec. 4. Repeat Steps 2 & 3 for the Right dispense tip. The Rinse LED will turn OFF, when the Rinse procedure has been satisfied for both sides. 5. Open the cabinet door and select Normal on the Function Selector switch – close the door.
The dispenser can be set to not dispense product when the concentrate BIB is empty. To enable this feature, first calibrate the Empty BIB Threshold (refer to Field Calibrating the Empty BIB Warning). Then enable the BIB Empty Lockout feature (refer to the BIB Empty Lockout menu in Programming the Dispenser). The dispenser will now Lockout dispensing and flash the Right or Left “REFILL LED” corresponding to the empty BIB. Once the BIB has been replaced, PRIME the concentrate line (refer to Priming the Concentrate Lines) and then dispense mixed product until the “REFILL LED” goes out. NOTE: If the dispenser fails to clear the BIB Empty Lockout, repeat the Priming operation a second time to insure the concentrate is flowing properly.
The dispenser can be set to not dispense product if the hot water is not up to the preset READY temperature. To enable this feature set the READY temperature to the minimum allowable dispense temperature. Then enable the Brew Lockout feature, refer to READY TEMP and BREW LOCKOUT, in Programming the Dispenser.
34766 042304

Remove the lower splash guard assembly to access the digital programming module with LCD display. Press the Down Arrow key to inter the programming menu. Use the Up and Down Arrow keys to scroll through the menu screens. Select Exit to leave the programming function and return to normal operations. NOTE 1: Flashing menu items indicate which selection is active. NOTE 2: Values shown below are the factory default values for English units. NOTE 3: Values in [X - X] are the Min. and Max. for that function.
TANK TEMP XXX
Use the Down Arrow Key to enter Programming Functions
Normal Display for LCA models, (No Chiller)
TANK TEMP XXX CABINET TEMP XX
Use the Down Arrow Key to enter Programming Functions
Normal Display for LCC models, (with Chiller)
Enter the desired Mix Ratio for the concentrate used in the Left dispenser. [20:1 - 100:1]
Use the (+) or (-) buttons to adjust the Mix Ratio
(-) 35:1 (+)
Select tube size.
Enter Pump Tube Size to be used in the Left metering pump, (see Tube Selection Chart)
R DISPENSE RATIO
Use the (+) or (-) buttons to adjust the Mix Ratio
Enter the desired Mix Ratio for the concentrate used in the Right dispenser. [20:1 - 100:1]
(-) 35:1 (+)
Select tube size.
Enter Pump Tube Size to be used in the Right metering pump, (see Tube Selection Chart)
FLAVOR GUARD ?
Select (YES) to activate. Select (NO) to deactivate.
Select Yes, if you are ready to calibrate the Flavor Guard sensor. Select NO, if you do not wish to use this feature, (see Flavor Guard)
If NO - go to LF DISP VOLUME menu.
Select (YES) or (NO)
Select YES, if you have dispensed several cups and are satisfied with the Left dispenser flavor. Select NO, if you have not run taste test.
Place a 16 Oz. (500 mL) cup under the Left dispense tip, then activate the Left dispenser
Calibrates the Left FlavorGard™ sensor to the current MixProfile. The dispenser will shut OFF automatically when finished.
Select (YES) or (NO)
Select YES, if you have dispensed several cups and are satisfied with the Right dispenser flavor. Select NO, if you have not run taste test.
Place a 16 Oz. (500 mL) cup under the Right dispense tip, then activate the Right dispenser
Calibrates the Right FlavorGard™ sensor to the current MixProfile. The dispenser will shut OFF automatically when finished.
34766 042304

LOCK FLAVOR ?
Select (YES) or (EXIT)
Select YES, to Lock In sensor calibration. NOTE: Display will return to “Find LF Target” if sensor calibration is out of range.
FLAVORS LOCKED
NONE
Confirms that sensor calibration was in range and accepted. Scroll down to continue.
Portion Control Settings for Pull and Hold Dispensers For Portion Control Dispensers (LCA-2 PC, LCA-2C PC, LCA-2A PC) go to Full Time Portion Control Settings
Use the (+) or (-) buttons to adjust the Left portion volume
Set the volume to be dispensed during a Left Portion controlled dispense to: [0 - 640 Oz.] or [0 - 18.93L]
(-) 4.0oz (+)
Use the (+) or (-) buttons to adjust the Right portion volume
Set the volume to be dispensed during a Right Portion controlled dispense to: [0 - 640 Oz.] or [0 - 18.93L]
(-) 4.0oz (+)
Full Time Portion Control Settings
Use the (+) or (-) buttons to adjust the Normal Left volume
Set the desired portion control volume to be dispensed during a Normal Left dispense to: [0 - 640 Oz.] or [0 - 18.93L]
(-) 4.0oz (+)
Use the (+) or (-) buttons to adjust the Alternate Left volume
Set the desired portion control volume to be dispensed during a Alternate Left dispense to: [0 - 640 Oz.] or [0 - 18.93L]
(-) 0.0oz (+)
Use the (+) or (-) buttons to adjust the Normal Right volume
Set the desired portion control volume to be dispensed during a Normal Right dispense to: [0 - 640 Oz.] or [0 - 18.93L]
(-) 4.0oz (+)
Use the (+) or (-) buttons to adjust the Alternate Right volume
Set the desired portion control volume to be dispensed during a Alternate Right dispense to: [0 - 640 Oz.] or [0 - 18.93L]
(-) 0.0oz (+)
Use the (+) or (-) buttons to adjust the Normal Hot Water volume
Set the desired portion control volume to be dispensed during a Normal Hot Water dispense: [0 - 640 Oz.] or [0 - 18.93L]
(-) 0.0oz (+)
Use the (+) or (-) buttons to adjust the Alternate Hot Water volume
Set the desired portion control volume to be dispensed during a Alternate Hot Water dispense: [0 - 640 Oz.] or [0 - 18.93L]
(-) 0.0oz (+)
34766 120105

TANK TEMP 180
Use the (+) or (-) buttons to adjust the target Temp.
Sets the water Tank temperature [120 - 200°F] or [49 - 93°C]
READY TEMP 175
Use the (+) or (-) buttons to adjust the target Temp.
Sets the hot water Ready temperature. Typically set to the minimum desired dispense temp.
CABINET TEMP 65
Use the (+) or (-) buttons to adjust the target Temp.
LF PRODUCT DISP
Select (RESET) to clear total
Selecting Reset will clear the Current accumulated volume of concentrate dispensed through the Left dispenser. Gal (Liters)
LF PRODUCT DISP
NONE
Displays the Total accumulated volume of concentrate dispensed through the Left dispenser. Not Re-settable. Gal (Liters)
RT PRODUCT DISP
Select (RESET) to clear total
Selecting Reset will clear the Current accumulated volume of concentrate dispensed through the Right dispenser. Gal (Liters)
RT PRODUCT DISP
NONE
Displays the Total accumulated volume of concentrate dispensed through the Right dispenser. Not Re-Settable. Gal (Liters)
The following functions can be Password Protected. If you wish to prevent others from accessing these functions, enter a 4 digit code of your choice. Record your password code [ ], as you will need it to access these functions in the future.
Use the (+) or (-) buttons to enter password.
Enter the access Code to view the remaining functions. Factory Default = 0.
Use the (+) or (-) buttons to change the password.
Enter your own Code to prevent access to the remaining functions. [0 to 9999]
Select the preferred units
Used to select the preferred units of measurement. (Oz., Gal, deg F) or (mL, L, deg C)
Select (YES) or (NO)
LCA Models without Chiller select (NO) LCC Models with Chiller select (YES)
Select (YES) or (NO)
Selecting Yes will enable the Rinse Alarm function, (see Rinse Alarm)
If NO - go to BIB EMPTY LOCKOUT menu.
(-) 0 (+) · (-) 0 (+) · 34766 120105

RINSE TIME ? (-) 12 Hrs (+)
Use the (+) or (-) buttons to adjust Rinse Alarm delay
Enter the desired time between required Rinse Cycles in hours, [8 - 24 hrs.]
Select (YES) to enable
Select YES to Lockout dispensing until the Rinse Alarm has been cleared. Default is NO
Select (YES) to enable
Select YES to Lockout dispensing until the Concentrate BIB has been replaced. Default is NO
NO EXIT YES
BREW LOCKOUT ?
NO EXIT YES
Select (YES) to enable
Select YES to Lockout dispensing until the hot water tank is at READY Temp. Default is NO
(-) 0 SEC (+)
Use the (+) or (-) buttons to adjust the Delay Time
Enter the desired time delay before allowing the next dispense to take place, [0 - 10 sec.]
The following functions are for diagnostic and troubleshooting purposes and typically do not have to be adjusted. Contact your local service agent for assistance before making changes to these functions.
Select (YES) to enable
Selecting Yes will enable the Left Dispenser Calibration routine, (see Field Calibration before attempting to calibrate the dispenser).
If NO - go to CAL RIGHT SIDE menu.
Place a 50 mL (#34843.1000) graduated cylinder under the Left dispense tip, then activate the Left Dispenser
The Left Pump will dispense concentrate for 20 seconds, then shut off automatically. Collect and measure the concentrate dispensed.
PULL DISPENSE
Use the (+) or (-) buttons to enter volume collected
Enter the volume of concentrate measured from the Left Pump in mL, (not Oz.) regardless of Preferred Units selected.
Place a 64 Oz. (2000 mL) container under the Left dispense tip, then activate the Left Dispenser
The Left Dispenser will dispense hot water for 20 seconds, then shut off automatically. Collect and measure the water dispensed.
PULL DISPENSER
Use the (+) or (-) buttons to enter volume collected
Enter the volume of the water measured from the Left dispenser in Oz. (mL).
NONE
Scroll down to bypass this screen.
EXIT YES
Select (YES) to enable Calibration routine.
Selecting Yes will enable the Right Dispenser Calibration routine, (see Pump Calibration) prior to calibrating the dispenser.
EXIT YES
(-) 43mL (+) · 34766 120105

If NO - skip to next menu.
Place a 50 mL (#34843.1000) graduated cylinder under the Right dispense tip, then activate the Right Dispenser
The Right Pump will dispense concentrate for 20 seconds, then shut off automatically. Collect and measure the concentrate dispensed.
CAL RT PUMP VOL
Use the (+) or (-) buttons to enter volume collected
Enter the volume of concentrate measured from the Right Pump in mL(not Oz.) regardless of Preferred Units selected.
Place a 64 Oz. (2000 mL) container under the Right dispense tip, then activate the Right Dispenser
The Right Dispenser will dispense hot water for 20 seconds, then shut off automatically. Collect and measure the water dispensed.
CAL RT WTR VOL (-) 36.0OZ (+)
Use the (+) or (-) buttons to enter volume collected
Enter the volume of the water measured from the Right dispenser in Oz. (mL)
NONE
Scroll down to bypass this screen.
For Portion Control Dispensers (LCA-2 PC, LCA-2C PC, LCA-2A PC) only
Place a 64 Oz. (2000 mL) container under the Hot Water dispense tip, then activate the Hot Water Dispenser
The Hot Water Dispenser will dispense for 20 seconds, then shut off automatically. Collect and measure the water dispensed.
CAL HOT WTR VOL
Use the (+) or (-) buttons to enter volume collected
Enter the volume of the water measured from the Hot Water Dispenser in Oz. (mL)
XXX CAL -> XXX
Use the (+) or (-) buttons to adjust temperature reading
Adjust the display reading to match a calibrated probe inserted next to the Tank Sensor, °F (°C).
Use the (+) or (-) buttons to adjust % value
Used to set the maximum adjustment the Flavor Guard feature is allowed to make, [3 - 15%].
LfFlvrGrdTargets RPM XXX-CON XXX
Displays the Left Dispenser target RPM and Conductance Reading, (Diagnostics Only)
RtFlvrGrdTargets RPM XXX-CON XXX
Displays the Right Dispenser target RPM and Conductance Reading, (Diagnostics Only)

BIB EMPTY -> 500
Use the (+) or (-) buttons to adjust empty BIB threshold
Used to set the Conductance Threshold for the Empty BIB warning. Default is 500
XX REFILL -> 155
Use the (+) or (-) buttons to adjust Refill threshold
Used to set the Conductance Threshold for the Tank Refill Probe.
WTR START DELAY
Use the (+) or (-) buttons to adjust delay time
Dispense Valve ON Delay. Eliminates weak mix at the beginning of a dispense.
WTR STOP DELAY
Use the (+) or (-) buttons to adjust delay time
Dispense Valve OFF Delay. Flushes the mix chamber at the end of a dispense.
TEST LED’S ? NO EXIT YES
Select (YES) or (NO)
LED diagnostics. Selecting YES will light all Front Door LED’s.
NONE
Switch Diagnostic: Activate switches separately to test. Display will indicate which Switch has been activated. NOTE: Door Interlock switch must be held closed.
Refill Valve Diagnostic: Press YES to momentarily energize the Solenoid. CAUTION: Inlet Valve will open and water will flow, if connected and turned ON.
Tank Heater Diagnostic: Press YES to momentarily energize the Tank Heater Circuit. CAUTION: AC power will be applied to the Tank Heater Circuit.
ENTER ASSET #
Use the (+) or (-) buttons to adjust the ASSET NUMBER
Allows the user the option of entering an Asset Number. Default is 000000
NONE
Displays the manufacture’s Serial Number (should be identical to the Serial Number on the machine Data Plate)
Select (YES) or (NO)

LOADING THE CONCENTRATE 1. Thoroughly mix concentrate by vigorously shaking the product Bag-In-Box (BIB). 2. Pull the BIB connector through the hole provided in the box and place it on the drip tray with the connector facing up. (See Fig. 1) 3. Open the dispenser door and locate the appropriate left or right BIB Adapter fitting. 4. Pull the Adapter fitting down and connect it to the BIB. (See Fig. 2) 5. Place the BIB upright in the machine, rotating it into position with the connector facing forward. 6. Rotate the BIB Adapter to avoid sharp bends in the tubing and allow it to be routed between the two pumps. Refer to the Tube Installation Decal on the door for proper routing. (See Fig. 3) 7. Close the cabinet door.



Fig. 1 Fig. 2 Fig. 3
PRIMING THE CONCENTRATE LINES 1. Open the dispenser door. 2. Load concentrate per instructions in the section titled Loading the Concentrate. 3. Select Prime on the Function Selector Switch and Run on the Mode Selector Switch. 4. Close the dispenser door. 5. Place a container under the appropriate dispense tip. 6. Activate the appropriate dispenser until concentrate flows from the dispense nozzle. Priming may take 5 to 10 seconds. 7. Open the dispenser door, select Normal on the Function Selector Switch, and then close door. Note: Concentrate may continue to drip out of dispense tip. The user may wish to run a Rinse Cycle (refer to Rinsing) after Priming the dispenser to clean out the remaining concentrate.

34766 042304

OPERATING THE PULL & HOLD DISPENSER (Models LCA-2, LCA-2C, LCA-2A, LCC-2, LCC-2C, LCC-2A) Set the Function Selector Switch to Normal and the Mode Selector Switch to Run. 1. Pull and Hold Dispense Mode (Cup at a time) a. Place cup on the cup tray beneath the desired dispensing tip. For a large container, flip the cup tray up
and place the container on top of the drip tray. b. Pull and Hold the corresponding dispense handle until the cup or other container is full. c. Remove cup or container. 2. Portion Dispense Mode (Preset volume dispensing) Refer to Programming Functions on how to set this volume. a. Place the appropriate size container beneath the desired dispensing tip. For large containers, flip the cup
tray up and place the container on top of the drip tray. b. Momentarily press the Portion Switch. The Portion LED will illuminate for 5 seconds after the Portion
Switch is pressed. c. Momentarily pull the corresponding dispense handle, then release. If the user waits longer than 5 seconds
to pull the handle, the dispenser will default back to the Pull & Hold Mode. Portion Dispense Mode can be disabled at any time during the portion dispense by either momentarily pulling the Dispense Handle again or pressing the Stop button. d. Wait for container to fill and the dispenser to quit dispensing, then remove container. 3. Hot Water Dispense a. Place container under the hot water dispenser (center of machine). For large containers, flip the cup tray
up and place the container on top of the drip tray. b. Push and hold the Hot Water Switch until the water reaches the desired level, then release. c. Remove container.
Filling Cambros or other large containers: The dispenser is designed primarily for cups or other small containers that will fit under the dispense tips. However, it may be used to fill larger containers (up to 2 Gal) by use of an extension hose on the dispense tip. Removing the Flow Restrictors will increase the dispenser flow rate to 2.5 Oz/sec. (74 mL/sec.) and reduce the time to fill larger containers, (see Setting Dispenser Flow Rate.) Care must be taken to insure that the mixed product flows freely from the dispense tip into the container. 1. Use a 5/8” I.D. or larger, NSF (National Sanitation Foundation) approved hose. 2. Use as short a hose as possible with no loops, bends or kinks in it. 3. Insure that the outlet of the hose is below the dispense tip and that the mixed product flows freely into the container A properly sized and positioned hose will not run full or back up into the dispense tip. Failure to follow these directions can alter the mix ratio and/or cause flooding of the vent tube. NOTE: The temperature of the product being dispensed will start to drop after ~2 gal. continuous draw. Recovery time will be dependent on the temperature of the supply water and the voltage at which the heater coil is being operated.
34766 042304

(Models LCA-2 PC, LCA-2C PC, LCA-2A PC) Set the Function Selector Switch to Normal and the Mode Selector Switch to Run.
Dispensing Preset Portions of Coffee or Hot Water 1. Primary Volume Portion Dispense Mode. (Volume 1) Refer to Programming Functions on how to set this amount. a. Place cup on the cup tray beneath the desired dispensing tip. For a large container, flip the cup tray up
and place the container on top of the drip tray. b. Momentarily press the appropriate dispense switch. The dispenser will automatically dispense the beverage
at the preset amount. Allow the mix chamber to drain at the end of the cycle. c. Remove cup or container. 2. Alternate Volume Portion Dispense Mode. (Volume 2) Refer to Programming Functions on how to set this volume. a. Place the appropriate size container beneath the desired dispensing tip. For large containers, flip the cup
tray up and place the container on top of the drip tray. b. Momentarily press the Portion Switch. The Portion LED will illuminate for 5 seconds after the Portion
Switch is pressed. c. Momentarily press the corresponding Dispense Switch. If the user waits longer than 5 seconds to push
the switch, the dispenser will default back to the Primary Volume preset amount. Alternate Portion Dispense Mode can be disabled at any time during the portion dispense by either momentarily pushing the Dispense Switch again or pressing the Stop button. d. Wait for the container to fill and the dispenser to quit dispensing, then remove the container.
Push and Hold Dispensing of Coffee or Hot Water Push and Hold Dispense Mode. See Programming Functions on how to set the Preset Volume to Zero.
a. Place cup on the cup tray beneath the desired dispensing tip. For a large container, flip the cup tray up
and place the container on top of the drip tray. b. Push and hold the corresponding dispense switch until the container is full. c. Remove cup or container.
Filling Cambros or other large containers: The dispenser is designed primarily for cups or other small containers that will fit under the dispense tips. However, it may be used to fill larger containers (up to 5 Gal) by use of an extension hose on the dispense tip. Removing the Flow Restrictors will increase the dispenser flow rate to 2.5 Oz/sec. (74 mL/sec.) and reduce the time to fill larger containers, (see Setting Dispenser Flow Rate.) Care must be taken to insure that the mixed product flows freely from the dispense tip into the container. 1. Use a 5/8” I.D. or larger, NSF (National Sanitation Foundation) approved hose. 2. Use as short a hose as possible with no loops, bends or kinks in it. 3. Insure that the outlet of the hose is below the dispense tip and that the mixed product flows freely into the container A properly sized and positioned hose will not run full or back up into the dispense tip. Failure to follow these directions can alter the mix ratio and/or cause flooding of the vent tube. NOTE: The temperature of the product being dispensed will start to drop after ~2 gal. continuous draw. Recovery time will be dependent on the temperature of the supply water and the voltage at which the heater coil is being operated.
34766 120105

General Cleaning and Sanitizing Procedures Note: The BUNN® Liquid Coffee Dispenser incorporates a “user selectable” rinse reminder feature, which lights the Rinse LED on the front panel and disables dispensing when it is time to rinse. See Programming Functions to activate this feature.
Daily: RINSING 1. Open the dispenser door. 2. Select Rinse on the Function Selector Switch and Run on the Mode Selector Switch. 3. Close the dispenser door. 4. Place a 1/2 gal (2 liter) container under the appropriate dispense nozzle or nozzles. 5. Activate the Dispenser of the appropriate side or sides for approximately twenty seconds or until the hot water is clear or has no concentrate coloring in it. 6. Open the dispenser door, select Normal on the Function Selector Switch, and then close door. Note: To clear the “Rinse” alarm, activate each dispenser until the flow stops automatically (approx. 20 seconds for each tip). The “Rinse” alarm LED will turn off when the Rinse Procedure has been satisfied for both sides.
Daily: PARTS WASHING 1. Remove and wash the drip tray, drip tray cover, and cup tray in a mild detergent solution. Rinse thoroughly. 2. Wipe splash panel, area around dispense nozzles, door, and cabinet with a clean damp cloth.
Weekly: SANITIZING 1. Open the dispenser door. 2. Select Prime on the Function Selector Switch and Run on the Mode Selector Switch. 3. Remove the bag connector from the product box and disassemble or prop open the internal valve to allow free flow of product through the connector. NOTE: Cutting the mating fittings from an empty bag makes an excellent “free flowing” connector for this purpose. 4. Place the bag connector into a one-gallon (3.8 liter) container of warm soapy tap water 140°F (60°C). 5. Place an empty container under dispense tip and activate the corresponding Dispenser until the clean soapy water is dispensed from the dispense tip. 6. Repeat steps 4 and 5 with warm tap water 140°F (60°C) to rinse the soapy water from the pump tubing. Continue dispensing until the water is clear, and no soapy water is being dispensed. 7. Prepare 2.5 gallons (9.46L) of sanitizing solution by dissolving 1 packet of Kay 5 sanitizer into 2.5 gallons (9.46L) of 120°F (48.9°C) water to ensure 100 ppm of available chlorine. 8. Again, repeat steps 4 and 5 with the sanitizing solution. Once sanitizing solution is being dispensed, stop dispensing and allow the solution to sit for 5 minutes. 9. Repeat step 6 to flush out the sanitizing solution from the pump tubing. 10. Remove the mating connector from the bag connector. 11. Reattach the bag connector to product box. 12. Select Normal on the Function Selector Switch and Run on the Mode Selector Switch. 13. Activate the Dispenser until concentrate/water mixture appears. Then dispense one 12 ounce (354.9 ml) glass of concentrate/water mixture and discard. 14. Repeat steps 1 through 13 for other dispense head. 15. Wipe internal and external surfaces with a clean, damp cloth.
34766 042304

The pumps and tubing used in the dispenser are designed to give maximum performance and long life. However, the tubes are a wear item and must be replaced periodically. How long the tubes last is dependent on usage and properties of the concentrate. Excessive wear will reduce the output of the pumps resulting in a weak mixed beverage. Bunn-O-Matic recommends replacing the Pump Tubing a minimum of once every 6 months or sooner if warranted. Refer to the Tube Replacement Instruction on the Cabinet door for details. 1. Rinse the pump tubing with warm tap water (Refer to steps 1 - 5 of the Weekly Sanitizing instructions) prior to removing the tubes to avoid concentrate spills. 2. Loosen the thumbscrew securing the tubing retainer plate to the pump housing. Set it and the retainer plate aside. 3. Depress the tension screw and remove it from the notch in the pump housing, releasing the spring tension on the pump band. 4. Open the compression band and gently pull the pump tube from around the pump’s rotor. 5. Inspect the pump bands for signs of wear. Replace if necessary. 6. Apply lubricant (BUNN-O-MATIC part number M2531.0001) to the new pump tubing’s rotor side. 7. Insert the tube onto the mix chamber port, then wrap the new tubing around the pump rotor, making sure that the elbow and clamps end up on the bottom side of the pump housing. 8. Depress the tension screw and insert it in the notch in the pump body, reapplying spring tension on the pump band. 9. Replace the tubing retainer plate and tighten the thumbscrew. 10. Repeat steps 1 through 9 for the other pump.
2.0” 2.0” Tension Screw
Remove Retaining Plate Release Spring Tension Remove Tubing Lubricate New Tube
Install New Tubing Completed Installation

CAUTION: The dispenser must be disconnected from the power source throughout these steps. 1. Disconnect the dispenser from the power source. 2. Shut off and disconnect the incoming water supply. 3. Remove the front splash panel. 4. Pull out drain tube to empty into a sink or a container with a minimum of five-gallon capacity. 5. Make sure drain clamp is closed. Then, remove drain plug. 6. Direct tube into sink or container and open drain clamp. Continue draining tank until ALL of the water is out. Be very careful with the draining water because it can be very hot. 7. Close drain clamp, insert drain plug, place drain tube back into machine, and replace splash panel. Note: The dispenser must be refilled using the Initial Fill & Heat steps before reconnecting the power source.
34766 112502

Dispenser Not plugged in. AC Circuit Breaker OFF Power LED “OFF”
Check Power Cord Check the AC Power Circuit Breaker Service Required
Usage has exceeded the capacity of the Tank Heater Ready LED “OFF” Water Temp. Too Low
Check Tank Temp Setting Check Ready Temp. Setting Service Required: Change the Supply Voltage, see Optional Field Wiring
Rinse Dispenser, see Rinse Procedure Rinse Cycle Required Rinse LED “ON”
Rinse Dispenser, see Rinse Procedure Dispenser Locked Out Rinse Cycle Required Rinse LED “FLASHING”
Alternate Portion Dispenser Volume #2 has been selected Portion LED “ON”
Activate the Dispenser within 5 sec. to dispense the pre-selected volume.

Left Refill LED “ON”
Concentrate BIB is Empty. BIB Not properly connected Tubing kinked or blocked Empty BIB warning set too high
Replace BIB, see Loading the Concentrate Check BIB Connector Fittings Check Tubing Installation Check Threshold, see Field Calibrating the Emoty BIB Warning
Right Refill LED “ON”
Concentrate BIB is Empty. BIB Not properly connected Tubing kinked or blocked Empty BIB Warning set too high
Replace BIB, see Loading the Concentrate Check BIB Connector Fittings Check Tubing Installation Check Threshold, see Field Calibrating the Empty BIB Warning
Replace BIB, see loading the Concentrate Left Dispenser will not operate Left Refill LED
“FLASHING” Empty BIB Lockout
Left Dispenser will not operate
Replace BIB, see loading the Concentrate
“FLASHING” Empty BIB Lockout
The Dispenser has detected an Internal Fault
Remove the lower splash guard to view the Fault message, See Diagnostics. After the fault has been repaired or corrected - Hold the “Stop” button for 10 seconds to clear the message.

Screen Displayed Possible Cause Troubleshooting Procedures Dispenser Diagnostics-LCD Display
LF TARGET RPM TOO HIGH !!
Refer to “Selecting the Correct Pump Tubing” section of the manual.
Refer to recommended Dispense Ratio on the product label.
Refer to “Selecting the Correct Pump Tubing” section of the manual.
Refer to recommended Dispense Ratio on the product label.
Refer to “Selecting the Correct Pump Tubing” section of the manual.
Refer to recommended Dispense Ratio on the product label.
Refer to “Selecting the Correct Pump Tubing” section of the manual.
Refer to recommended Dispense Ratio on the product label.
Replace BIB, see loading the Concentrate
Check BIB Connector Fittings
Check Threshold, see Field Calibrating the Empty BIB Warning
Replace BIB, see loading the Concentrate
Check BIB Connector Fittings
Check Threshold, see Field Calibrating the Empty BIB Warning
Check Tubing installation · Check Tubing installation · 34766 011604

Screen Displayed Possible Cause Troubleshooting Procedures
Check water supply shut-off
TANK TEMP SENSOR OUT OF RANGE CHECK FOR BAD CONNECTIONS
TANK TEMP SENSOR OUT OF RANGE CHECK WIRE FOR SHORTS

Screen Displayed Possible Cause Troubleshooting Procedures
LEFT PUMP FAULT! CHK PUMP WIRING CHK RPM SENSOR CHK TUBING AREA
COOLER FAULT! EVAP TEMP TOO HI
Check wiring harness for breaks, shorts, open connectors
Check pump & tubing for proper installation Service Required

The factory set Default Values for the Pump & Dispenser Flow Rates are very accurate and typically do not need to be field calibrated. However, if the mix ratio accuracy is ever in question, this procedure can be used to recalibrate the unit in the field. Equipment Required: 50 to 100 ml graduated cylinder, with 1 ml graduations. 64 Oz (2000 ml) graduated container. Remove the lower splash guard assembly to access prior to starting this procedure NOTE: You can calibrate either the Concentrate Pump or the Dispenser Flow Rate independently. Simply scroll through the menu screen to the desired section and perform only those steps.
Calibrating the Left Side Dispenser
Concentrate Pump Calibration 1. Select PRIME on the Function Selector Switch. (refer to Priming the Concentrate Lines). 2. Place a container under the Left Dispense Tip and prime the concentrate lines until a steady stream of concentrate comes out the tip (approximately 10 seconds). 3. Stop the Priming and allow the tip to stop dripping. Discard the concentrate collected. 4. Select NORMAL on the Function Selector Switch. 5. Locate the programming module and use the Arrow Down key to scroll through LCD screens until CAL LEFT SIDE appears and press the YES button. 6. The CAL LEFT PUMP menu screen will be displayed. Place a 50 ml graduated cylinder under Left Dispense Tip and activate the Left Dispenser momentarily. The dispenser will run the Left Concentrate Pump for 20 seconds and then shut OFF automatically. 7. Keep the graduated cylinder under dispense tip until all the concentrate has dripped out. 8. Measure the volume of concentrate collected in the graduated cylinder.
Acceptable ranges for the volume collected Tubing Size Volume Collected 3/16” tubing 40 - 47 ml. 1/8” tubing 17 - 22 ml
9. If the amount collected is not within the acceptable range, empty the graduated cylinder and repeat STEPS 6 – 8. 10. If the amount collected is still not within range, replace the pump tubing with a new Tube Kit, (refer to the Tube Replacement Instructions). 11. When satisfied with the volume of concentrate collected, press the Down Arrow Key 12. The CAL LF PUMP VOL menu screen will be displayed. Use the (-) / (+) keys to adjust number displayed to the amount measured in STEP 8.
(Continued Next Page) · 34766 042304

(Continued)
Dispenser Flow Rate Calibration 13. Press Down Arrow Key to display the CAL LF WTR FLO menu screen. 14. Place a 64 Oz (2000 ml) graduated container under Left Dispense Tip and Pull the Left Dispense Handle momentarily. The dispenser will dispense water for 20 seconds and then shut OFF automatically. 15. Keep the graduated container under dispense tip until all the water stops dripping. 16. Measure the volume of water collected in the graduated container.
Acceptable ranges for the volume collected Dispenser Flow Rate Volume Collected 1.8 Oz/sec (53 ml/sec) w/ flow restrictor 32 - 38 Oz, (946 - 1124 ml) 2.5 Oz/sec (74 ml/sec) w/o flow restrictor 46 - 52 Oz ,(1360 - 1538 ml)
17. If the amount collected is not within the acceptable range, empty the graduated container and repeat STEPS 14 – 16 18. If the amount collected is still not within range, inspect the dispense valves, tubing and mix chamber for lime, kinks or other obstructions. 19. When satisfied with the volume of concentrate collected, press the Down Arrow Key. 20. The CAL LF WTR VOL screen will be displayed. Use the (-) / (+) keys to adjust number displayed to the amount measured in STEP 16. 21. Press Down Arrow Key again to exit the CAL LEFT SIDE functions.
Calibrating the Right Side Dispenser
Repeat STEPS 1-21 above for the “CAL RIGHT SIDE” menus.
Field Calibrating the Hot Water Flow Rate 1. Locate the programming module and use the Arrow Down key to scroll through the LCD screen until “CAL HOT WTR FLO?” appears. 2. Place a 64 Oz (2000 ml) graduated container under Hot Water Tip and press the hot water switch. The unit will dispense Hot Water for 20 seconds and then shut OFF automatically. Keep the graduated container under the dispense tip until all the water stops dripping. 3. Measure the volume of water collected in the graduated container. The acceptable range for the volume collected is 32 - 38 Oz. (946 - 1124 ml). 4. If the amount collected is not within the acceptable range, empty the container and repeat steps 2 & 3. 5. If the amount collected is still not within range, inspect the hot water valve, tubing and fittings for lime, kinks, or other obstructions. 6. When satisfied with the volume of concentrate collected, press the Down Arrow Key. 7. The “CAL HOT WTR VOL” screen will be displayed. Use the (-) / (+) keys to adjust number displayed to the ammount measured in step 3. 8. Press Down Arrow Key again to exit this function.
30 34766 120105

Field Calibrating the Empty BIB Warning The dispenser will automatically turn on the Left or Right “REFILL LED”, see Operating Controls and Interface, when the corresponding BIB is Empty. The Refill message is triggered when the FlavorGardTM sensor reading drops below the minimum setting. The factory set minimum is 500 and should be correct for most locations. However, in some areas the hardness of the local water supply may effect this reading. If the Refill message doesn’t come on when the BIB is empty or the message comes on too early and there is still concentrate left in the BIB, use the following procedure to find the correct Empty BIB threshold.
Calibrating The Empty BIB Threshold 1. Remove the lower splash guard assembly to access the digital programming module with LCD display. 2. Open the cabinet door and set the Function Switch to the “Rinse” position. Close the door. 3. Place a large container under the Left dispenser tip, then activate and hold the left dispenser. 4. Dispense long enough to rinse all the concentrate out of the mix chamber and for the Conductance reading to stabilize and stop dropping. 5. Record the nominal Conductance value displayed. (NOTE: It is typical for this value fluctuate (+/- 25) points about the nominal value}. This is the conductance reading of the water in your area. 6. Repeat steps 3, 4 & 5 for the Right dispenser. 7. Add 100 points to the larger of the Left or Right side Conductance value. This is the new Empty BIB threshold value for your dispenser. 8. Enter this new value into the Empty BIB Alarm threshold, see Programming the Dispenser.
34766 120105

N (120V 2-Wire) N (120/208-240V 3-Wire) L2 (208-240V 2-Wire)

120 VOLTS AC 2 WIRE 120/208-240 VOLTS AC 3 WIRE 208-240 VOLTS AC 2 WIRE SINGLE PHASE 50/60HZ
32 34766 010407


120 VOLTS AC 2 WIRE 120/208-240 VOLTS AC 3 WIRE 208-240 VOLTS AC 2 WIRE SINGLE PHASE 50/60HZ
34766 010407

L1 N
CAPACITOR .01uF CAPACITOR .01uF

34 34766 092706