Silver Series®


BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644
To ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts Catalog, Programming Manual, or Service Manual, please visit the Bunn-O-Matic website, at www.bunn.com This is absolutely FREE, and the quickest way to obtain the latest catalog and manual updates. For Technical Service, contact Bunn-O-Matic Corporation at 1-800-286-6070.

BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCP/MCA pod brewers thermal servers and Thermofresh servers (mechanical and digital)- 1 year parts and 1 year labor. 2) All other equipment - 2 years parts and 1 year labor plus added warranties as specified below: a) Electronic circuit and/or control boards - parts and labor for 3 years. b) Compressors on refrigeration equipment - 5 years parts and 1 year labor. c) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis - parts and labor for 4 years or 40,000 pounds of coffee, whichever comes first.
These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect, alteration, improper installation or operation, improper maintenance or repair, non periodic cleaning and descaling, equipment failures related to poor water quality, damage or casualty. In addition, the warranty does not apply to replacement of items subject to normal use including but not limited to user replaceable parts such as seals and gaskets. This warranty is conditioned on the Buyer 1) giving BUNN prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Office Box 3227, Springfield, Illinois 62708-3227; 2) if requested by BUNN, shipping the defective equipment prepaid to an authorized BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under warranty. THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EX PRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make modifications to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and should not be relied upon. If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive op tion while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during the applicable parts and labor warranty periods specified above) to repair the defective components, provided that this repair is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase price for the equipment. THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND. In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.
392, A Partner You Can Count On, Air Infusion, AutoPOD, AXIOM, BrewLOGIC, BrewMETER, Brew Better Not Bitter, Brew WISE, BrewWIZARD, BUNN Espress, BUNN Family Gourmet, BUNN Gourmet, BUNN Pour-O-Matic, BUNN, BUNN with the stylized red line, BUNNlink, Bunn-OMatic, Bunn-O-Matic, BUNNserve, BUNNSERVE with the stylized wrench design, Cool Froth, DBC, Dr. Brew stylized Dr. design, Dual, Easy Pour, EasyClear, EasyGard, FlavorGard, Gourmet Ice, Gourmet Juice, High Intensity, iMIX, Infusion Series, Intellisteam, My Café, Phase Brew, PowerLogic, Quality Beverage Equipment Worldwide, Respect Earth, Respect Earth with the stylized leaf and coffee cherry design, Safety-Fresh, savemycoffee.com, Scale-Pro, Silver Series, Single, Smart Funnel, Smart Hopper, SmartWAVE, Soft Heat, SplashGard, The Mark of Quality in Beverage Equipment Worldwide, ThermoFresh, Titan, trifecta, Velocity Brew, Air Brew, Beverage Bar Creator, Beverage Profit Calculator, Brew better, not bitter., BUNNSource, Coffee At Its Best, Cyclonic Heating System, Daypart, Digital Brew er Control, Element, Milk Texturing Fusion, Nothing Brews Like a BUNN, Pouring Profits, Signature Series, Sure Tamp, Tea At Its Best, The Horizontal Red Line, Ultra are either trademarks or registered trademarks of Bunn-O-Matic Corporation. The commercial trifecta® brewer housing configuration is a trademark of Bunn-O-Matic Corporation.

CONTENTS Warranty 2 User Notices 3 Initial Set-Up & Electrical Requirements 4 Plumbing Requirements 4 CE Requirements 4 Door Cover Installation 5 Plumbing Hookup 6 Initial Fill 6 Loading 15 Priming 15 Operating Controls 8 Dispenser Use 10 Portion Control Option 10 Cleaning 12 Adjustments & Optional Settings 14 Function Lists 18 Troubleshooting 20 Coolant Diagram 26 Schematic Wiring Diagram 27 Quick Setup Guide 29
Carefully read and follow all notices on the equipment and in this manual. They were written for your protec tion. All notices are to be kept in good condition. Replace any unreadable or damaged labels.
As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration (FDA), this equipment must be installed with adequate backflow prevention to comply with federal, state and local codes. For models installed outside the U.S.A., you must comply with the applicable Plumb- ing /Sanitation Code for your area.
12559.0003
27442.7000
CHARGE Type R134A, Amount 10 oz (283 gm) Design Pressures: High 335 psi (23 bar) (2.31 MPa) Low 88 psi (6 bar) (0.61 MPa)
CHARGE Type R134A, Amount 9 oz (255 gm) Design Pressures: High 255 psi (15.5 bar)
33461.0000 JDF-4S
33461.0001 JDF-2S
44744.2 082112

INITIAL SET-UP CAUTION: The dispenser is very heavy! Use care when lifting or moving it. Use at least two people to lift or move the dispenser. Place dispenser on a sturdy counter or shelf able to support at least 150 lbs. (68 kg). This dispenser is designed for indoor use only. Set the dispenser on the counter where it will be used. This dispenser requires a minimum of 4 inches (102 mm) of air clearance at the rear and 8 inches (203 mm) of air clearance above the dispenser. Minimal clearance is required between the dispenser sides and the wall or another appliance. For optimum performance, do not let warm air from surrounding machines blow on the dispenser. Leave some space so the dispenser can be moved for cleaning.
ELECTRICAL REQUIREMENTS CAUTION: The dispenser must be disconnected from the power source until specified in Electrical Hook-Up. The 120V rated dispensers have an attached cord set and require a 2-wire, grounded, individual branch circuit rated 120 volts ac, 15 amp, single phase, 60Hz. The mating connector must be a NEMA 5-15R. The 220-230V rated dispenser has an attached cord set and requires an attachment plug cap rated at least 230 volts ac, 15 amp. The attachment plug cap must meet with applicable national/local electrical codes. Refer to the data plate for exact electrical requirements.
ELECTRICAL HOOK-UP CAUTION: Improper electrical installation will damage electronic components. 1. An electrician must provide electrical service as specified. 2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source. 3. Confirm that the refrigeration switch near the main control board is in the OFF position. 4. Connect the dispenser to the power source. 5. If plumbing is to be hooked up later, be sure the dispenser is disconnected from the power source. If plumbing has been hooked up, the dispenser is ready for Initial Fill.
PLUMBING REQUIREMENTS This dispenser must be connected to a COLD WATER system with operating pressure between 20 and 100 psi (138 and 690 kPa). This water source must be capable of producing a minimum flow rate of 3 fluid ounces (88.7 milliliters) per second. A shut off valve should be installed in the line before the dispenser. Install a regulator in the line when pressure is greater than 100 psi (690 kPa) to reduce it to 50 psi (345 kPa). The regulator is also necessary if the water source has pressure fluxuations. The main water inlet is a 3/8” (9.52 mm) MFL connection. NOTE- At least 18 inches (457 mm) of an FDA approved flexible beverage tubing, such as reinforced braided polyethylene, before the dispenser will facilitate movement to clean the countertop. It can be purchased direct from BUNN-O-MATIC (part number 34325.10_ _ [see Illustrated Parts Catalog for complete part number.]) BUNN-O-MATIC does not recommend the use of saddle valves to install the dispenser. The size and shape of the hole(s) made in the supply line(s) by saddle valves may restrict water flow.
As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration (FDA), this equipment must be installed with adequate backflow prevention to comply with federal, state and local codes. For models installed outside the U.S.A., you must comply with the applicable Plumbing /Sanitation Code for your area.



JDF-4S


JDF-2S & JDF-4S


JDF-2S
44744.2 110813

PLUMBING HOOKUP The plumbing connection is located on the rear of the dispenser. A 3/8" (9.52 mm) male flare adapter fitting is supplied, installed on the rear of the dispenser. NOTE - Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed and maintained in accordance with federal, state and local codes.


FIG 2 Plumbing Connections - JDF-4S
INITIAL FILL CAUTION: The dispenser must be disconnected from the power source throughout the initial fill except when
specified in the instructions. 1. Remove drip tray assembly and splash panel from the dispenser. Replace the drip tray. 2. Connect the water source to the back of the dispenser. 3. Pull the fill tube from the dispenser, remove the plug and connect it to the dispense nozzle (Fig. 5 & 6). 4. Set the Program Switch (Fig. 7) to the ON position. (On older models without program switch, set the Dis pense Lockout Switch (Fig. 13) to the OFF position) 5. Connect dispenser to the power source. Press and hold the dispense button for the dispense station that the tube is connected to for 10 seconds, until you hear the water valve turn on. (For Portion Control machines, press and hold the PLUS/STOP switch) 6. Monitor the water bath fill level until water starts to trickle from the overflow tube. Then press the dispense button again to stop the fill process. NOTE: The fill timer may time out before filling is complete. Press and hold the dispense button for 10 seconds to start again if needed.


FIG 4 Initial Fill Hose - JDF-4S
44744.2 110813

7. Turn ON the refrigeration switch near the main control board (Fig. 7). This will start the water bath pump circulation. 8. Check water level in the overflow tube and top off the tank if necessary (Step 5). 9. Disconnect the fill tube and allow excess water to drain into the drip tray. Replace the plug in the end of the fill tube and store back into the dispenser. 10. Set the Program Switch (near main control board) to the OFF position. (On older models without program switch, set the Dispense Lockout Switch to the ON position) 11. Replace the splash panel and drip tray. 12. It will take several hours to create the ice bank required for full dispenser performance. During this time, some further trickling from the water bath is expected due to expansion caused by ice bank formation. While the refrigeration system is creating the ice bank, the dispenser may be readied for use as described in Loading, Priming and Adjustment.


FIG 5 Initial Fill Connection - JDF-2S
44744.2 110813

Refrigeration Switch The refrigeration switch is located on the Electrical Panel of the dispenser near the Circuit Board. This switch controls power to the water bath pump and relay contacts for the compressor and condenser fan motor.

Product Dispense Switch (Mechanical Switch Machines) Pressing and holding switch will initiate product flow from the respective nozzle; releasing the switch will stop the flow.


FIG 10 Product Dispense Switches - JDF-4S
44744.2 110813

Product Dispense Switch (Membrane Switch Machines) A. Product Dispense Switch Momentarily pressing and releasing one of the switches will initiate a timed dispense. Each station has three different timed dispenses which are preset at the factory. Refer to DISPENSER USE section for preset volumes and adjustment procedures. B. Plus/Stop Switch This switch can be used to “top-off” a beverage. Pressing and holding switch will initiate product flow from the respective nozzle; releasing the switch will stop the flow. Momentarily pressing this switch during a timed dispense will stop the flow. C. Chilled Water Dispense Switch (Optional for JDF-4S only) Pressing and holding switch will initiate chilled water flow from the nozzle; releasing the switch will stop flow.


FIG 12 Product Dispense Switches - JDF-4S
Dispense Lockout Switch This switch is located at the bottom front of the dis penser just behind the drip tray. It is used to turn ON and OFF the Dispensing function. It is also used for some programming and fill procedures.

Program Switch This switch is located near the main control board next to the refrigeration switch.
44744.2 110813

DISPENSER USE Press and Hold Dispensing: 1. Place a cup on the drip tray beneath the desired dispensing nozzle. 2. Press and hold the “Product Dispense” switch until the beverage reaches the desired level, then release.
Portion Control Option (Mechanical Switch Machines) The dispenser is also equipped with a portion control option. The following steps will guide you through the set up process for this option. Portion control can be set on one or all dispense heads as needed. 1. Unplug dispenser from power source. 2. Set the Program Switch (near main control board) to the ON position. (On older models without program switch, set the Dispense Lockout Switch to the OFF position) 3. Remove drip tray and splash panel from the front of the machine then replace the drip tray. 4. Press and hold the left most (Station 1) dispense switch while plugging the dispenser into the power source. Continue holding dispense switch(s) until all 4 temperature LED’s, Figs. 15 and 16 on the circuit board start flashing slowly (this takes about 5 seconds). Release dispense switch(s). 5. Press and release any dispense switch 6 times to enter the portion control set up mode. This will cause the 4 temperature LED’s to flash rapidly. 6. Place a container under the desired dispense nozzle to measure the portion size. 7. Press and hold the desired dispense switch to dispense product until the desired amount of product is achieved. (Maximum dispense time is 150 seconds). Repeat this on all dispense heads as desired. 8. Set the Program Switch (near main control board) to the OFF position. (On older models without program switch, set the Dispense Lockout Switch to the ON position) 9. Place a container under the dispense nozzle(s) and press the dispense button to confirm that the portion size is set correctly. Repeat steps 1-8 if any changes are needed. 10. Replace splash panel. Note: The portion control dispense can be cancelled during a dispense by pressing the dispense button again. Note: If a portion size is not set for a dispense head while in the portion control set up mode, that dispense head will remain a push and hold dispense head.
Push and Hold Membrane Switch Machines 1. To set single portion sizes on a push and hold membrane type dispense switch, follow steps 1 - 10 above.
Portion Control Option (Membrane Switch Machines) Portion sizes are preset but can be adjusted by following these steps below. 1. Set the Program Switch (near main control board) to the ON position. (On older models without program switch, set the Dispense Lockout Switch to the OFF position) 2. Press and hold the large and medium buttons on the left most (Station #1) dispense station until you hear the machine "beep" three times. 3. Place a measuring container under the station to be adjusted, then press and hold the apprpriate dispense switch until the desired amount is dispensed. The machine will record the amount of time that the button is pressed continously. If the button is released too soon, simply empty the container and start over. 4. Repeat step 3 for all stations as desired. 5. Turn the program switch to the OFF position.

Procedure to return all dispense heads back to Push and Hold mode (Mechanical Switch Machines): 1. Unplug dispenser from power source. 2. Place Program switch in the ON position. 3. Remove drip tray and splash panel from the front of the machine then replace the drip tray. 4. For the JDF-2S, press and hold either dispense switch while plugging the dispenser into the power source. For the JDF-4S, press and hold two left dispense switches while plugging the dispenser into the power source. Continue holding dispense switch(s) until all 4 temperature LED’s on the circuit board start flashing slowly (this takes about 5 seconds). Release dispense switch(s). 5. Press and release any dispense switch three times. 6. Place Program switch back into the OFF position. 7. Replace splash panel and drip tray. 8. Place a container under each dispense nozzle and press dispense buttons to confirm machine is operating in push and hold mode.


FIG 16 Temperature LEDs JDF-4S
(Early Models)

(Late Models)
44744.2 062912

Daily: Rinse Procedure Tools required: 32 oz. (946 ml) minimum empty container 1. Open dispenser door. Lift up on product containers and remove them from the machine. 2. Close the door, place an empty container under the dispensing nozzle. 3. Dispense from each station until clear water flows from the dispense nozzle. 4. Open dispenser door and reconnect all product containers.
Daily: Parts Washing 1. Remove and wash the dispense nozzle(s), drip tray and drip tray cover in a mild detergent solution. Rinse thoroughly. Use brush (00674.0000) to clean inside and oring area on dispense nozzles. 2. Wipe splash panel, areas around dispense nozzle(s), and refrigerated compartment with a clean, damp cloth. 3. Use brush and a mild detergent solution to clean inside dispense area where dispense nozzles are removed. Rinse.
Sanitize Process for Semi-Automatic and Manual Tools required: 1 empty 5 gallon (18.9 L) bucket, 2 packets of Kay 5 sanitizer, and clean, empty concentrate container. 1. Remove all concentrate from the dispenser and store in a separate refrigerated compartment. 2. Fill clean empty concentrate container(s) with approximately 32 oz. (946 ml) of hot tap water (approximately 140 Deg. F (60 Deg. C). Load the containers of hot water into the dispenser (just like concentrate). 3. Place an empty container under the dispense nozzles. 4. Press and hold the dispense button at each station until the stream out of the nozzles runs clear (about 30 seconds). Note: the dispenser will not allow all stations to run at the same time. 5. Once this is completed, remove the container(s) and empty. 6. Remove each dispense nozzle and mixing element and run under hot tap water to remove excess pulp. 7. Prepare 2.5 gal. (9.46 L) of sanitizing solution by dissolving 1 packet of Kay 5 sanitizer into 2.5 gal. (9.46 L) of 120 Deg F (48.9 Deg. C) water to ensure 100 ppm of available chlorine. 8. Place nozzle(s) and mixing element(s) in a separate 1-quart container of sanitizing solutions and mix thoroughly. Allow the parts to soak for 2 minutes. 9. Clean the dispense nozzle receptacle(s) (dispense valves) with the sanitizing solution and a soft bristle brush. 10. Clean the concentrate bottle’s inlet adapter(s) using the sanitizing solution and a soft bristle brush. 11. Replace the mixing element(s) and nozzle(s). 12. Fill approximately 128 ounces (3.8 L) of clean sanitizing solution into clean, empty concentrate container(s). Do not use the sanitizing solution used in step 10. Load the container(s) into the dispenser. 13. Place the empty 5 gallon bucket under the dispense nozzles. For Semi-Automatic Sanitizing Prior to S/N JDF0016500: 14. a. For the JDF-2S, press and hold both dispense buttons for about 10 seconds to initiate the sanitize cycle. b. For the JDF-4S, press and hold three left most dispense buttons (Stations 1, 2 and 3) for about 10 seconds to initiate the sanitize cycle. The cycle will start with only one of the dispense stations dispensing. Note: The cycle will consist of a 1 minute dispense time (alternating) on each station, then 5 minutes of soak time, then a 2 minute dispense time (alternating) on each station. For Semi-Automatic Sanitizing Effective S/N JDF0016500 and up: 14. Turn the Program Switch in the bottom of the machine to the "ON" position. a. For the JDF-2S, press the left dispense button 2 times, then press the right dispense button 2 times. b. For the JDF-4S, press the left most (station 1) dispense button 2 times, then the left center (station 2) button 2 times. The cycle will start with only one of the dispense stations dispensing. Note: The cycle will consist of a 1 minute dispense time (alternating) on each station, then 5 minutes of soak time, then a 2 minute dispense time (alternating) on each station. For Manual Sanitizing: 14. a. Dispense each station for 1 minute. b. Allow to soak for 5 minutes. c. Dispense each station for 2 minutes. NOTE: On Portion Control models, use the plus/stop switches. 15. When the above cycle is complete, Remove the sanitizing solution and replace with concentrate. 16. At each station, press and hold the dispense switch until product appears. Then dispense one 12 ounce (354.9 ml) glass of finished product and discard. 17. Wipe internal and external surfaces with a clean, damp cloth.

Monthly: Clean Condenser Coils and Filter 1. Removable filter can be cleaned in warm soapy water. 2. Use a soft bristle brush to clean the build up of dirt in the condenser.
1. Open dispenser door. 2. Remove all product containers and place them in a refrigerated (35-40 degrees F [1.6-4.4 degrees C]) envi ronment. Disconnect all connections to ambient products from the bottle adapter. 3. Rinse all dispense stations using steps outlined in “DAILY RINSE PROCEDURE”. 4. Disconnect dispenser from power source. 5. Remove the dispense platform cover. 6. Disconnect the dispense platform water line(s) from the supply line inside the refrigerated cabinet and dis connect the wiring connection(s) from the cabinet receptacle(s). 7. Remove the mounting screw(s) securing the dispense platform(s) to the cabinet . 8. Pull the dispense platform(s) completely out of the cabinet and place it on a flat work surface. 9. Close the dispenser door. 10. Remove the 4 screws securing the pump head. 11. Gently pull the pump head apart. 12. Gently pull the pump tube from around the pump’s rotor. 13. Release the clamps securing the old pump tubing to the plastic elbows. 14. Pull the plastic elbows from the old pump tubing, and discard the old pump tubing. 15. Insert the plastic elbows into the new pump tubing and secure it with the clamps. 16. Gently wrap the new pump tubing around the pump’s rotor. 17. Reassemble the pump housing onto the platform assembly. 18. Repeat steps 10 through 17 for the remaining pump(s). 19. Replace the dispense platform(s) into the refrigerated cabinet, making sure to reconnect all electrical and water connections. 20. Replace the dispense platform cover. 21. Turn power on to dispenser. 22 Install containers of rinse water, run each station and check for leaks. Repair leaks as necessary. 23. Replace product shelf and product containers. Reconnect any connections to ambient product containers. 24. Prime the pumps as described in “PRIMING” in the Initial Fill Section.

Water Flow Testing and Adjustment NOTE: Purge all dispense stations to remove air from water line before making initial adjustments. 1. Place a graduated measuring cup or the large chamber of the empty brixing cup (BUNN-O-MATIC part number 33095.0000) under the appropriate dispense nozzle. Place the Program switch in the ON position. 2. Press and release the desired “Product Dispense Switch” three times.(On Portion Control models, use the plus/stop switches) 3. The selected position will dispense water (no concentrate) only for 3 seconds. 4. Measure the water dispensed. Suggested target is 3 ounces (1 ounce per second flow rate. 5. Adjust the water flow rate Fig 17, (clockwise to increase flow rate; counterclockwise to decrease flow rate) to the corresponding product mix ratio. Chart below provides general brix instructions.
Using 1/4" allen wrench
Mix Ratio Adjust water flow rate to: Product Brix % (water + concentrate) 2+1 *3.0 fl. oz (89 ml) Prune Juice 16.0% per 3-second test Other * Orange Juice 11.8% 4+1 Pineapple Juice 12.8% Cranberry Fruit Cocktail 14.0% *3.0 fl. oz (89 ml) Grapefruit Juice 10.6% per 3-second test Lemonade 5+1 Apple Juice 12.0% Fruit Punch Grape Juice 13.0% 3+1 through 7+1 Other * Above 7+1 *4.0 fl. oz (118 ml) Other * per 3-second test High Viscosity Juice 3.0 fl. oz (89 ml) As Required - per 3-second test *Maximum flow rate may be less depending on the water pressure supply at each location. Note: Information for specific products listed in this table is to be used for reference only. Consult the product label for exact mix ratio and/or brix %. See product label for target brix %.
6. Repeat steps 1 through 5 as necessary until the correct water flow rate is achieved. 7. Repeat steps 1 through 5 for the remaining dispense positions. 8. Place the Program switch back into the OFF position. Pump Speed Adjustment 1. Disconnect the dispenser from the power source. 2. Remove the drip tray. 3. Remove the two screws securing the splash panel and remove the splash panel 4. Locate the adjustment knobs on the circuit board. NOTE: Start with the adjustment dial in the nine o'clock position. 5. Turn the adjustment knobs clockwise to increase speed and counterclockwise to decrease speed. NOTE: If splashing occurs while dispensing, reduce water flow rate. Then re-adjust pump speed to achieve proper ratio/ brix target. 6. The knob positions directly correspond to dispense station locations. NOTE: Some 2S models have 4 adjustment knobs on the circuit board. For these models use the two left most knobs to make pump speed adjustments. Left most being station #1 (left side dispense) and left center being station #2 (right side dispense). 7. Reinstall the splash panel and drip tray and reconnect the dispenser to the power source.

Frozen Concentrates 1. Thaw the frozen concentrate in a refrigerated 35-40 degrees F (1.6-4.4 degrees C) environment for 36 to 48 hours before use. NOTE: Loading frozen concentrate in the product cabinet may cause damage to the machine. This damage is not covered by warranty. 2. Thoroughly mix the thawed concentrate by vigorously shaking the product container. 3. Open the dispenser door. 4. Prior to placing the product container in the dispenser, make sure that the o-ring on the container adapter is lubricated. This will ease removal of the container when it becomes necessary. 5. Place the product container in the desired position and press it firmly into the bottle adapter opening. 6. Open the vent hole in the product container. Note: Concentrate in the container must be completely thawed and be within the temperature range of 35-40 degrees F (1.6-4.4 degrees C.) Product outside of this temperature range, especially below, will produce an “out of brix” drink.
Ambient Concentrates (Optional) 1. Install an Ambient Concentrate Conversion Kit (BUNN-O-MATIC part number 33699.0002) per the instruc tions provided in the kit. 2. Attach the concentrate product hose to the appropriate concentrate line located at the rear of the dispenser. 3. Attach the other end of the product hose to the product container through an appropriate fitting.

Total Dispense Ratio Set Up Procedure 1. Adjust water flow as described in Water Flow Testing and Adjustment. Record water output setting for later reference on each dispense head. Suggested target is 3 ounces. 2. Place the Program switch in the ON position. 3. Place a measuring container under the dispense nozzle, press and release the DISPENSE button 6 times. NOTE: For best results, discard the first sample and measure a second sample. Repeat the same practice after every adjustment. 4. Record the total ounces dispensed. 5. Refer to the Brix/Ratio chart below to confirm proper total dispensed amount for ratio desired and water output previously recorded. 6. To increase or decrease the product output, refer to Pump Speed Adjustment section. 7. Place the Program switch back into the OFF position.
Ratio Target 2:1 3:1 4:1 5:1 6:1 7:1 8:1 9:1 10:1 11:1 12:1 1.5 2.25 2.00 1.88 1.80 1.75 1.71 1.69 1.67 1.65 1.64 1.63 1.75 2.63 2.33 2.19 2.10 2.04 2.00 1.97 1.94 1.93 1.91 1.90 2.0 3.00 2.67 2.50 2.40 2.33 2.29 2.25 2.22 2.20 2.18 2.17 2.25 3.38 3.00 2.81 2.70 2.63 2.57 2.53 2.50 2.48 2.45 2.44 2.5 3.75 3.33 3.13 3.00 2.92 2.86 2.81 2.78 2.75 2.73 2.71 2.75 4.13 3.67 3.44 3.30 3.21 3.14 3.09 3.06 3.03 3.00 2.98 3.0 4.50 4.00 3.75 3.60 3.50 3.43 3.38 3.33 3.30 3.27 3.25 3.25 4.88 4.33 4.06 3.90 3.79 3.71 3.66 3.61 3.58 3.55 3.52 3.5 5.25 4.67 4.38 4.20 4.08 4.00 3.94 3.89 3.85 3.82 3.79 3.75 5.63 5.00 4.69 4.50 4.38 4.29 4.22 4.17 4.13 4.09 4.06 4.0 6.00 5.33 5.00 4.80 4.67 4.57 4.50 4.44 4.40 4.36 4.33
3 second water dispense
Ratio Target 2:1 3:1 4:1 5:1 6:1 7:1 8:1 9:1 10:1 11:1 12:1 44.4 66.5 59.1 55.5 53.2 51.8 50.7 49.9 49.3 48.8 48.4 48.1 51.8 77.6 69.0 64.7 62.1 60.4 59.1 58.2 57.5 56.9 56.5 56.1 59.1 88.7 78.9 73.9 71.0 69.0 67.6 66.5 65.7 65.1 64.5 64.1 66.5 99.8 88.7 83.2 79.8 77.6 76.0 74.9 73.9 73.2 72.6 72.1 73.9 110.9 98.6 92.4 88.7 86.3 84.5 83.2 82.1 81.3 80.7 80.1 81.3 122.0 108.4 101.7 97.6 94.9 92.9 91.5 90.4 89.5 88.7 88.1 88.7 133.1 118.3 110.9 106.5 103.5 101.4 99.8 98.6 97.6 96.8 96.1 96.1 144.2 128.1 120.1 115.3 112.1 109.8 108.1 106.8 105.7 104.8 104.1 103.5 155.3 138.0 129.4 124.2 120.8 118.3 116.4 115.0 113.9 112.9 112.1 110.9 166.4 147.9 138.6 133.1 129.4 126.7 124.8 123.2 122.0 121.0 120.1 118.3 177.4 157.7 147.9 141.9 138.0 135.2 133.1 131.4 130.1 129.0 128.1
44744.2 110813

Temperature Compensated Refractometer Method 1. Adjust the water flow as described in Water Flow Testing and Adjustment. 2. Place an empty container under the appropriate dispense nozzle. 3. Press and hold the “Product Dispense Switch” Figs 9 & 10, until water and concentrate begin flowing freely from the dispense nozzle. 4. Discard the product caught previously and place the empty container back under the dispense nozzle. 5. Press and hold the “Product Dispense Switch” until the cup is filled. 6. Stir the contents of the cup, and use the refractometer (according to the manufacturer’s instructions) to check the brix %. 7. Adjust the pump speed (down to decrease the brix %; up to increase the brix %) to achieve the correct brix % as described in Pump Speed Adjustment.
Optional Cold Water Flow Adjustment Some dispensers are equipped with an optional cold water dispense valve. It is recommended to adjust the flow rate upon initial set up of the dispenser. The adjustment for the cold water can be located inside the dispenser behind the right service panel. The cold water dispense valve is mounted to the frame just above the ice bath. Attached to this valve is a needle type adjustment valve. Turn the adjustment clockwise to decrease the water flow, and counter-clockwise to increase the water flow.
Dispenser Lockout Dispense functions of the dispenser can be turned-off to prevent unauthorized use of the dispenser, while keeping the refrigeration system running.

Circuit Board LED Indicators - JDF-2S (Early Models)
LED # LED Color Illuminates: 1 Green When the compressor should be ON. 2 Cabinet Red When the cabinet temperature is above 50 degrees F. Flashes slowly when cabinet temperature exceeds 50 degrees F for 4 hours. Dispense functions are locked out under this condition. Power down the dispenser to reset.
Flashes rapidly if dispense is attempted in lockout condition.
Open cabinet thermistor circuit will flash #2 and #3 LED’s 1 time every 3 seconds.
Shorted cabinet thermistor will turn #2 and #3 LED’s on steady. *This mode disables the cabinet low temperature lockout fault. 3 Cabinet Green When cabinet temperature is below 50 degrees F. 4 Bath Red When bath temperature is above 34 degrees F. Flashes slowly when compressor is in a 6 minute delay period.
Open bath thermistor circuit will flash #4 and #5 LED’s 1 time every 3 seconds. The compressor will not run under this condition.
Shorted bath thermistor circuit will flash #4 and #5 LED’s 2 times every 3 seconds. The compressor will not run under this condition. 5 Bath Green When bath temperature is below 34 degrees F.
(Early Models)
44744.2 110813

Circuit Board LED Indicators - JDF-4S and Late Model JDF-2S
LED # LED Color Illuminates: 1 Bath Red When bath temperature is above 34 degrees F. Flashes slowly when compressor is in a 6 minute delay period.
Open bath thermistor circuit will flash #1 and #2 LED’s 1 time every 3 seconds. The compressor will not run under this condition.
Shorted bath thermistor circuit will flash #1 and #2 LED’s 2 times every 3 seconds. The compressor will not run under this condition. 2 Bath Green When bath temperature is below 34 degrees F. 3 Green When the compressor should be ON. 4 Cabinet Red When the cabinet temperature is above 50 degrees F. Flashes slowly when cabinet temperature exceeds 50 degrees F for 4 hours. Dispense functions are locked out under this condition. Power down the dispenser to reset.
Flashes rapidly if dispense is attempted in lockout condition.
Open cabinet thermistor circuit will flash #4 and #5 LED’s 1 time every 3 seconds.
Shorted cabinet thermistor will turn #4 and #5 LED’s on steady. *This mode disables the cabinet low temperature lockout fault. 5 Cabinet Green When cabinet temperature is below 50 degrees F.
44744.2 110813

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department.
Cold Water Circulation Dispense stations not working. Note: Cooling failure or excessive cabinet temperatures for more than 4 hours will result in dispense lockout or no dispense. Note: Reset fault/timer by unplug ging unit.
Replace fan (24vdc). Note: Fan receives power when the dispenser is powered.
A) If not running, check refrigera tion switch and wiring for proper continuity.
B) Check for 120V or 230V AC at pump. Replace pump.
Check for kinked hose.
Dispense nozzle dripping/won't stop dispensing.
A) Remove dispense nozzle. Clean nozzles and oring in mild detergent solution.
B) Use soft bristle brush and mild detergent solution to clean dispense valve area that dispense nozzles are seated.
Clean or replace switches.
Check continuity of dispense switches. Replace as needed.

PROBLEM PROBABLE CAUSE REMEDY
Refrigeration Dispense stations not working. Note: Cooling failure or excessive bath and cabinet temperatures for more than 4 hours will result in dispense lockout or no dispense.
Check for "ON" position or no con tinuity - replace switch.
Clean filter and fins or replace con denser filter. (Filter not supplied on some machines).
A) Check for 120V or 230V AC. Re place fan motor or check fan blades for obstructions.
B) Check compressor LED on circuit board. If ON, relay coil should have power (120 or 230 VAC).
Check compressor relay coil for 120 or 230vac. NOTE: Always check power with coil attached. If compressor LED is ON and no 120 or 230vac - re place board. If yes, 120 or 230vac - replace relay. Note: Relay contacts are normally open.
Check compressor thermal overload (N/C). If open check for dirty con denser filter or adequate ventilation and space around machine.
Check refrigeration system for leaks and proper charge.
Dispenser Locked Out Dispense stations not working.
(A) Set switch to ON position.
(B) Check switch and harness for proper continuity.
Cooling system failure.
Check all previous items that pre tain to refrigeration or cold water recirculation

PROBLEM PROBABLE CAUSE REMEDY
Dispense station not working
Place switch in ON position.
Check switch and harness for proper continuity.
Main water supply
Check for ON position.
A) Compressor relay/contacts shorted - replace relay.
B) Recirculating pump - replace or check for kinked flex line.
A) Check for 120V or 230V power when dispensing. If yes, replace valve. If no, check harness for proper continuity. Then replace circuit board if needed.

PROBLEM PROBABLE CAUSE REMEDY
Dispense station concentrate only
Water solenoid
Replace solenoid (24vdc) or check wire connection between water valve and main control board.
Concentrate out
Replace refill concentrate container or BIB
Product pump not pumping
Check for proper counterclockwise rotation of pump rollers. If coun terclockwise, replace pump tubing. If clockwise, wire connection to pump is reversed. Switch wires on terminals.
A) Check speed setting on circuit board and increase speed (turn clockwise)
B) Check for d.c. power to pump motor. If yes, replace motor assy. If no, check harness for proper con tinuity. Then replace circuit board if needed.

PROBLEM PROBABLE CAUSE REMEDY
Water leak filling drip tray or around dispense deck area
1. Initial fill/setup
Some expansion normal. May fill drip tray during initial ice block formation
2. Dispense deck
Inspect or replace fittings clamps, o-rings, solenoids and quick discon nect fittings. NOTE: Dispense deck area slopes to drain tube that leads to the drip tray.
Install water pressure regulator and reduce to 50 psi.
A) Check all internal water connec tions.
B) Check internal plumbing con nections.
Check for routing of condensation tube to water bath.
Dispense nozzle mixer missing or broken
Replace mixer.
Dispense solenoid.
Replace dispense deck solenoid.

PROBLEM PROBABLE CAUSE REMEDY
Unit is not working
Check for 120/24 or 230/24 vac. If no 24vac reading, replace step-down transformer.
If 24 vac present and no LED’s lit, replace control board..
Maintain 20 psi or higher and a minimum flow rate of 3 fl oz/sec.
Over 100 psi, install a pressure regulator and set to 50 psi.
A) Perform 3 second water dispense test. Factory setting is 1.0 oz/sec. Acceptable water flow rate is .-0.8 to 1.5 oz/sec depending on the mix ratio (4+1).
B) Adjust water to proper mix ratio. Once water is set, adjust motor speed to achieve brix %.
Check for proper brix ratio per prod uct using Total Dispense method and or refractometer method.
Inspect, clean, or replace tubing and pump rotor/rollers for ease of rotation.
A) Follow plumbing requirements for pressure and flow rate.
B) Source another portable pump or water supply that meets require ments.
Vacuum leak
Inspect all lines and connections from bag-in-box connector to bottle adapter assembly.

PROCESS TUBE
EVAPORATOR
ACCUMULATOR COMPRESSOR
SUCTION
FILTER
DRYER
CONDENSER
44744.2 062912

(Models with LED Lited Doors)

44744.2 062912

(Models with Flourescent Lited Doors)
220-230V MODELS

44744.2 030813

(Models with LED Lited Doors)

44744.2 062912

(Models with Flourescent Lited Doors)
220-230V MODELS

44744.2 030813






6. Connect power supply to machine. (See Electrical Requirements)





Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.