JDF-2
INSTALLATION & OPERATING MANUAL
POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644
35303.0000 12/03 ©2003 Bunn-O-Matic Corporation

CONTENTS Introduction & Warranty 2 User Notices 3 Initial Set-Up & Electrical Requirements 4 Plumbing Requirements 4 Operating Controls 7 Initial Fill 5 Dispenser Use 9 Cleaning 10 Adjustments & Optional Settings 13 Function Lists 18 Coolant Diagram 20 Schematic Wiring Diagram 21
Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 years parts and 1 year labor. 2) Electronic circuit and/or control boards: parts and labor for 3 years. 3) Compressors on refrigeration equipment: 5 years parts and 1 year labor. 4) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis: parts and labor for 3 years or 30,000 pounds of coffee, whichever comes first.
These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect, alteration, improper installation or operation, improper maintenance or repair, damage or casualty. This warranty is conditioned on the Buyer 1) giving BUNN prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Office Box 3227, Springfield, Illinois 62708-3227; 2) if requested by BUNN, shipping the defective equipment prepaid to an authorized BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under warranty.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make modifications to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and should not be relied upon.
If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive option while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/ or labor (during the applicable parts and labor warranty periods specified above) to repair the defective components, provided that this repair is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase price for the equipment.
THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND.
In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.
BUNN, and JDF-2 are either trademarks or registered trademarks of Bunn-O-Matic Corporation.
35303 081503

Carefully read and follow all notices on the equipment and in this manual. They were written for your protec- tion. All notices are to be kept in good condition. Replace any unreadable or damaged labels.


DO NOT OVERLOAD CIRCUIT. ALWAYS ELECTRICALLY GROUND THE CHASSIS OR ADAPTOR PLUG. DO NOT DEFORM PLUG OR CORD. FOLLOW NATIONAL AND LOCAL ELECTRICAL CODES. KEEP COMBUSTIBLES AWAY.
BEFORE USING THIS PRODUCT 00986.0002E 5/98 ©1994 Bunn-O-Matic Corporation
27442.0000 00986.0002


12559.0003

CHARGE Type R134A, Amount 9 oz Design Pressures: High 255 Low 36
33461.0001
35303 012703

Set the dispenser on the counter where it will be used. The JDF-2 requires a minimum of 4 inches (102 mm) of air clearance at the rear and 8 inches (203 mm) of air clearance above the dispenser. Minimal clearance is required between the dispenser sides and the wall or another appliance. For optimum performance, do not let warm air from surrounding machines blow on the JDF-2. Leave some space so the dispenser can be moved for cleaning.
The 120V rated dispensers have an attached cord set and require a 2-wire, grounded, individual branch circuit rated 120 volts ac, 15 amp, single phase, 60Hz. The mating connector must be a NEMA 5-15R. (Refer to the data plate for exact electrical requirements.)
The 230V rated dispensers have an attached cord that requires an attachment plug cap rated at least 10a, 230V. The attachment plug cap must meet with applicable national/local electrical codes.
ELECTRICAL HOOK-UP CAUTION: Improper electrical installation will damage electronic components.
This dispenser must be connected to a COLD WATER system with operating pressure between 20 and 100 psi (138 and 690 kPa). This water source must be capable of producing a minimum flow rate of 3 fluid ounces (88.7 milliliters) per second. A shut off valve should be installed in the line before the dispenser. Install a regulator in the line when pressure is greater than 100 psi (690 kPa) to reduce it to 50 psi (345 kPa). The main water inlet is a 3/8” (9.52 mm) MFL connection.
Additionally, the dispenser’s rinse connection may be connected to a HOT WATER system. Caution: MAXIMUM RINSE WATER TEMPERATURE: 170 degrees F (76.6 degrees C)
Use BUNN-O-MATIC tubing, part number 32759.10_ _ (see Illustrated Parts Catalog for complete part number) for hot water connection.
The rinse water operating pressure must be between 20 and 100 psi (138 and 690 kPa). A shut off valve should be installed in the line before the dispenser. Install a regulator in the line when pressure is greater than 100 psi (690 kPa) to reduce it to 50 psi (345 kPa). The rinse water inlet is a 1/4" (6.35 mm) MFL connection.
35303 081503

number.]) BUNN-O-MATIC does not recommend the use of saddle valves to install the dispenser. The size and shape of the hole(s) made in the supply line(s) by saddle valves may restrict water flow.
This equipment must be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).
CAUTION: The dispenser must be disconnected from the power source throughout the initial fill except when specified in the instructions. 1. Remove drip tray assembly and splash panel from the dispenser. 2. Pull the overflow tube from its retaining clip and connect it to the main water source (black gasket is supplied in install kit). 3. Slowly open the water shut off valve and fill the water bath until water trickles from the overflow. 4. Connect dispenser to the power source. 5. After 3 minutes of power, slowly add more water to the tank until water trickles from overflow again. 6. Once water bath is filled, remove water source, cap dispenser fill line, and store the fill tube in it’s holder (the fill tube can now be used as a sight glass). 7. Replace the splash panel and drip tray. 8. Place refrigeration switch to the “ON” position. It will take approximately three hours at 75° F (24° C) ambient to create the ice bank required for full dispenser performance. During this time, some further trickling from the water bath is expected due to expansion caused by ice bank formation. While the refrigeration system is creating the ice bank, the dispenser may be readied for use as described in Plumbing, Loading, Priming and Adjustment.

FIG 1 Initial Fill Connection
35303 081503

All plumbing connections are located on the rear of the dispenser. Both the rinse and potable water line must be connected to a water source. A water hookup kit is included with each dispenser.

FIG 2 Plumbing Connections
Frozen Concentrates 1. Thaw the frozen concentrate in a refrigerated 35-40 degrees F (1.6-4.4 degrees C) environment for 36 to 48 hours before use. 2. Thoroughly mix the thawed concentrate by vigorously shaking the product container. 3. Open the dispenser door. 4. Prior to placing the product container in the dispenser, make sure that the o-ring on the container adapter is lubricated. This will ease removal of the container when it becomes necessary. 5. Place the product container in the desired position and press it firmly into the bottle adapter opening. 6. Open the vent hole in the product container.
Ambient Concentrates (Optional) 1. Install an Ambient Concentrate Conversion Kit (BUNN-O-MATIC part number 33699.0001) per the instructions provided in the kit. 2. Attach the concentrate product hose to the appropriate concentrate line located at the rear of the dispenser. 3. Attach the other end of the product hose to the product container through an appropriate fitting.
PRIMING 1. Open the dispenser door 2. Load concentrate per instructions in section titled Loading. 3. Close the dispenser door. 4. Place a large container under the appropriate dispense nozzle. 5. Dispensers with Press and Hold Feature: Press and hold the “Product Dispense Switch” Fig 4, until concentrate dispenses from the dispense nozzle. Dispensers with Portion Control Feature:
Press and hold the “+/STOP Switch” Fig 5, until concentrate dispenses from the dispense nozzle. Note: This may take several seconds, depending on the installation and programmed pump speed.
35303 012703


Refrigeration Switch The refrigeration switch is located on the top of the dispenser near the left rear corner. This switch controls power to the compressor and the condenser fan motor.

Sanitize Switch The sanitize switch is located behind the drip tray in the lower left corner of the chassis. The drip tray can be removed to provide easy access to the switch. The sanitize switch is used to enter and exit the sanitize mode and to initiate the sanitize automatic cycle. Refer to Weekly Sanitizing in the Cleaning section for detailed instructions on the use of this switch.
35303 012703

OPERATING CONTROLS (cont.)
B

FIG 5 Press and Hold Models A. Product Dispense Switch
Pressing and holding switch will initiate product flow from the respective nozzle; releasing the switch will stop the flow. B. Hidden Switch
These switches are used to access, change and exit the dispenser program mode. C. Lock Switch
This switch is used to lockout the dispensing capabilities.
FIG 6 Portion Control Models B. Hidden Switch
These switches are used to access, change and exit the dispenser program mode. C. Lock Switch
This switch is used to lockout the dispensing capabilities. D. Product Dispense Switch
Momentarily pressing and releasing one of the switches will initiate a timed dispense. Each station has three different timed dispenses which are preset at the factory. Refer to DISPENSER USE section for preset volumes and adjustment procedures. E. Plus/Stop Switch
This switch can be used to “top-off” a beverage. Pressing and holding switch will initiate product flow from the respective nozzle; releasing the switch will stop the flow. Momentarily pressing this switch during a timed dispense will stop the flow.
35303 012703

Press and Hold Models (Refer to Fig 5) 1. Place a cup on the drip tray beneath the desired dispensing nozzle. 2. Press and hold the “Product Dispense” switch until the beverage reaches the desired level, then release.
Portion Control Models (Refer to Fig 6) 1. Place a cup on the drip tray beneath the desired dispensing nozzle. 2. Momentarily press the appropriate cup size switch to dispense the beverage. The dispenser is factory preset to produce the approximate beverage sizes as follows:
Small (4.0 seconds): approximately 7 fl.oz. (207 ml) Medium (6.9 seconds): approximately 12 fl.oz. (355 ml) Large (9.1 seconds): approximately 16 fl.oz. (473 ml)
The dispense times can be individually programmed by following the procedures described in ADJUST- MENT - Cup Size Programming.
To stop a timed dispense, momentarily press the “+/Stop Switch”.
35303 012703

General Cleaning and Sanitizing Procedures Note: The Bunn Juice Dispenser incorporates a rinse reminder feature which lights
the rinse led on the front panel when it is time to rinse. See dip switch function list to activate this feature.
1. Open the refrigerated compartment’s door to access the “DISPENSE/RINSE” Knobs Fig 7. 2. Select the stations that will be rinsed and then rotate the appropriate Knob(s) to the rinse position. It is recommended that ALL dispense heads be rinsed daily. Note: If a station is in service lockout, leave its knob in the Dispense position. 3. Close the refrigerated compartment’s door. 4. Place the empty container under the dispense nozzle to catch the rinse water. (CAUTION: THE BUNN JUICE DISPENSER CAN BE PLUMBED FOR A HOT WATER RINSE. RINSE WATER CAUGHT
FIG 7 Dispense/Rinse Switch
IN THIS STEP SHOULD BE HANDLED WITH EXTREME CARE.) 5. Press and release the appropriate “Product Dispense Switch” Fig 5. This will initiate a timed rinse cycle. Portion control users can press any of the 3 “Product Dispense Switches” Fig 6, to initiate a timed rinse cycle. 6. Repeat for each dispense head. 7. Open the refrigerated compartment’s door and return each knob to the dispense position. 8. Actuate the station’s Dispense Switch until concentrate appears from the dispense nozzle.
Daily: Parts Washing 1. Remove and wash the dispense nozzle(s), mixing element(s), drip tray and drip tray cover in a mild detergent solution. Rinse thoroughly. 2. Wipe splash panel, areas around dispense nozzle(s), and drip trough in refrigerated compartment with a clean, damp cloth.
Weekly: Sanitizing Tools required: Nozzle tubing (BUNN-O-MATIC part number 03289.1002) recommended when sanitizing multiple dispense heads simultaneously, 1 empty 5 gallon (18.9 L) bucket, 1 packet of Kay 5 sanitizer, and clean, empty concentrate containers.
1. Remove any juice concentrate from the dispenser and store in a separate refrigerated compartment. 2. Perform the rinse procedures as previously described. (Note: If the dispenser is plumbed for hot water rinse, proceed to step 9.) 3. Fill clean empty concentrate container(s) with approximately 32 oz. (946 ml) of the hot tap water (approxi- mately 140°F (60°C). Load the containers of hot water into the dispenser (just like concentrate). Verify the rinse knobs are in the “DISPENSE” position. 4. Remove the drip tray and verify that the nozzle tubes are positioned within the empty bucket. 5. Press and hold the “Sanitize Switch” Fig 5, located on the front left portion of the base, for 5 seconds. The “SANITIZE” indicator on the front panel will begin to flash and the beeper will sound twice indicating that you have entered the sanitize mode.
35303 012703

A) The pumps at the selected dispense heads will run for 1 minute, or until the bottles filled
with hot water empty, whichever occurs first. B) The dispenser will sit idle for 5 minutes. C) The pumps at the selected dispense heads will run for 2 minutes or until the bottles filled
with hot water empty, whichever occurs first. D) The beeper will sound once every 3 seconds to indicate completion of the sanitize
routine.
8. Once the cycle is completed, disconnect the sanitizing hose(s) from the nozzle(s) and empty the bucket. 9. Remove each dispense nozzle and mixing element and run under hot tap water to remove excess pulp. 10. Prepare 2.5 gal. (9.46 L) of sanitizing solution by dissolving 1 packet of Kay 5 sanitizer into 2.5 gal. (9.46 L) of 120°F (48.9°C) water to ensure 100 ppm of available chlorine. 11. Place nozzle(s) and mixing element(s) in a separate 1 quart container of sanitizing solution and mix thoroughly. Allow the part to soak for 2 minutes. 12. Clean the dispense nozzle receptacle(s) (dispense valves) with the sanitizing solution and a soft bristle brush. 13. Clean the concentrate bottle’s inlet adapter(s) using the sanitizing solution and a soft bristle brush. 14. Replace the mixing element(s) and nozzle(s), reattach the sanitizing hose(s) to the nozzle(s), and insert the hoses into the catch bucket. 15. Fill approximately 96 ounces (2.8 L) of clean sanitizing solution into clean, empty concentrate container(s). Do not use the sanitizing solution used in step 11. Load the containers into the dispenser. 16. Repeat steps 5 through 8.
A) The pumps at the selected dispense heads will run for 1 minute, or until the bottles filled
with sanitizing solution empty, whichever occurs first. B) The dispenser will sit idle for 5 minutes. C) The pumps at the selected dispense heads will run for 2 minutes or until the bottles filled
with sanitizing solution empty, whichever occurs first. D) The beeper will sound once every 3 seconds to indicate completion of the sanitize
routine.
CLEANING (cont) · 35303 012703

Monthly: Clean Condenser Air Filter 1. Remove the condenser air filter located on the rear of the dispenser. 2. Using a water spray, clean the air filter.
Annually: Replace Pump Tubing 1. Open dispenser door. 2. Remove all product containers and place them in a refrigerated (35-40 degrees F [1.6-4.4 degrees C]) environment. Disconnect all connections to ambient products from the bottle adapter. 3. Close the dispenser door and dispense product at each station until the product runs clear. 4. Disconnect dispenser from power source. 5. Remove the DISPENSE/RINSE knobs Fig 7, all dispense nozzles, and the dispense platform cover. 6. Shut off the dispenser platform water valve located on the dispense platform. Disconnect the dispense platform’s water lines from the supply lines inside the refrigerated cabinet and disconnect the wiring connections from the cabinet receptacles. 7. Release the latch securing the dispense platform to the cabinet . 8. Slowly pull the dispense platform forward to allow access to the rear wiring harness connector. 9. Disconnect the rear wiring harness connector from its receptacle. 10. Pull the dispense platform completely out of the cabinet and place it on a flat work surface. 11. Close the dispenser door. 12. Remove the screw securing the tubing retainer plate to the pump body and set it and the tubing retainer plate aside. 13. Gently pull the socket head screw from its notch in the pump body, releasing the spring tension on the pump band. 14. Gently pull the pump tube from around the pump’s rotor. 15. Inspect the pump band for signs of wear. Replace if necessary. 16. Release the clamps securing the old pump tubing to the plastic elbows. 17. Pull the plastic elbows from the old pump tubing, and discard the old pump tubing. 18. Insert the plastic elbows into the new pump tubing and secure it with the clamps. 19. Apply lubricant (BUNN-O-MATIC part number M2548.0000) to the new pump tubing’s rotor side. 20. Gently wrap the new pump tubing around the pump’s rotor, making sure that the elbows and clamps end up on the top-side of the pump body and don’t protrude through the exit slots. 21. Replace the socket-head screw into its notch in the pump body. 22. Replace the tubing retainer plate and its retaining screw. 23. Repeat steps 12 through 21 for the remaining pumps. 24. Replace the dispense platform into the refrigerated cabinet, making sure to reconnect all electrical and water connections. 25. Turn the dispense platform water valve to the open position. Check for leaks. 26. Replace the dispense platform cover, DISPENSE/RINSE knobs and dispense nozzles. 27. Turn power on to dispenser. 28. Turn all DISPENSE/RINSE knobs to the RINSE positions. Close the door and run a rinse at each station. Check for leaks. 29. Replace product shelf and product containers. Reconnect any connections to ambient product containers. 30. Prime the pumps as described in “PRIMING” in the Initial Fill Section.
CLEANING (cont) · 35303 012703

SETTING THE MIX RATIO/BRIX Ratio Cup Method 1. Adjust the water flow as described in Water Flow Testing and Adjustment. 2. Remove the dispense nozzle from the appropriate dispense position. 3. Assemble, lubricate, and install the Flow Separator Assembly (BUNN-O-MATIC part number 32629.0000) into the dispense nozzle receptacle (dispense valve,) making sure to point the arrow on the separator body away from the dispenser. 4. Place an empty container under the Flow Separator Assembly. 5. Dispensers with Press and Hold Feature: Press and hold the “Product Dispense Switch” Fig 5, until water and concentrate begin flowing freely from the Flow Separator Assembly nozzles. Dispensers with Portion Control Feature:
Press and hold the “+/Stop Switch” Fig 6, until water and concentrate begin flowing freely from the Flow Separator Assembly nozzles. 6. Place the empty brixing cup (BUNN-O-MATIC part number 33095.0000) under the Flow Separator Assembly nozzles, small (concentrate) chamber to the left and large (water) chamber to the right. 7. Dispensers with Press and Hold Feature: Press and hold the “Product Dispense Switch” until concentrate reaches the 1 oz. (black line) mark. Dispensers with Portion Control Feature:
Press and hold the “+/Stop Switch” until concentrate reaches the 1 oz. (black line) mark. 8. Read the level in the water chamber. This reading directly determines the mix ratio (i.e. If the water level reads 4.0 oz., then the mix ratio is 4 [water] + 1 [concentrate].) 9. Adjust the pump speed (down to increase the ratio, up to decrease the ratio) to achieve the correct mix ratio as described in Pump Speed Programming. 10. Remove the Flow Separator Assembly and replace the dispense nozzle assembly into the dispense nozzle receptacle (dispense valve.)
Temperature Compensated Refractometer Method 1. Adjust the water flow as described in Water Flow Testing and Adjustment. 2. Place an empty container under the appropriate dispense nozzle. 3. Dispensers with Press and Hold Feature: Press and hold the “Product Dispense Switch” Fig 5, until water and concentrate begin flowing freely from the dispense nozzle. Dispensers with Portion Control Feature:
Press and hold the “+/Stop Switch” Fig 6, until water and concentrate begin flowing freely from the dispense nozzle. 4. Discard the product caught previously and place the empty container back under the dispense nozzle. 5. Dispensers with Press and Hold Feature: Press and hold the “Product Dispense Switch” until the cup is filled. Dispensers with Portion Control Feature:
Press and hold the “+/Stop Switch” until the cup is filled. 6. Stir the contents of the cup, and use the refractometer (according to the manufacturer’s instructions) to check the brix %. 7. Adjust the pump speed (down to decrease the brix %; up to increase the brix %) to achieve the correct brix % as described in Pump Speed Programming.
35303 012703

ADJUSTMENT & OPTIONAL SETTINGS (cont)

Water Flow Testing and Adjustment 1. Enter the “Pump Speed Programming” mode by simultaneously press- ing both “Hidden Switches” Fig 5 or Fig 6. Note that the beeper sounds twice and that the “PROGRAM” indicator begins flashing. 2. Place a graduated measuring cup or the large chamber of the empty brixing cup (BUNN-O-MATIC part number 33095.0000) under the appropriate dispense nozzle. 3. Press and hold the desired “Product Dispense Switch” Fig 5 (“+/Stop Switch” Fig 6, for portion control dispensers) for 5 seconds. Note that the beeper sounds once per second (6 times, total) during this period. 4. At the end of the 5 second period, the selected position will dispense water (no concentrate) for only 3 seconds. 5. Measure the water dispensed. 6. Adjust the water flow rate Fig 8, (clockwise to increase flow rate; counterclockwise to decrease flow rate) to the corresponding product mix ratio as follows:
FIG 8 Adjusting Water Flow
Mix Ratio Adjust water flow rate to: Product Brix % (water + concentrate)
2+1 3.75 fluid ounces (111 ml) Prune Juice 16.0% per 3-second test Other * Orange Juice 11.8% 4+1 Pineapple Juice 12.8% Cranberry Fruit Cocktail 14.0% 4.5 fluid ounces (133 ml) Grapefruit Juice 10.6% per 3-second test Lemonade 5+1 Apple Juice 12.0% Fruit Punch Grape Juice 13.0% 3+1 through 7+1 Other * Above 7+1 6.0 fluid ounces (177 ml) Other * per 3-second test Note: Information for specific products listed in this table is to be used for reference only. Consult the product label for exact mix ratio and/or brix %. See product label for target brix %.
Pump Speed Programming 1. Enter the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that the beeper sounds twice and that the “PROGRAM” indicator begins flashing. 2. To increase the pump speed, press and hold the right-hand “Hidden Switch” (filled circle) and then momentarily press the “Product Dispense Switch” Fig 5 (“+/STOP Switch” Fig 6, for portion control dispensers). Each time the “Product Dispense Switch “(+/STOP Switch”) is pressed, the motor speed is increased by one step (5 revolutions per minute [RPM].) Note that each step is confirmed by a single flash of the appropriate “REFILL” indicator and a single tone from the beeper. 3. To decrease the pump speed, press and hold the left-hand “Hidden Switch” (half-filled circle) and then momentarily press the “Product Dispense Switch (“+/STOP Switch” for portion control dispensers). Each time
35303 012703

ADJUSTMENT & OPTIONAL SETTINGS (cont)
the “Product Dispense” (“+/STOP”) Switch is pressed, the motor speed is decreased by one step (5 RPM.) Note that each step is confirmed by a single flash of the appropriate “REFILL” indicator and a single tone from the beeper. 4. Repeat as necessary at the remaining dispense stations. 5. Exit the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that the beeper sounds twice and that the “PROGRAM” indicator extinguishes.
Cup Size Programming (Portion Control Dispensers Only) 1. Enter the “Cup Size Programming” mode by simultaneously pressing the “LARGE” and “SMALL” cup size switches at any dispense station. Note that the beeper sounds twice and that the “PROGRAM” indicator lights steadily. 2. Press and hold the desired cup size switch at the appropriate dispense position until the correct cup volume is achieved. Top up as necessary by momentarily pressing the same cup size switch. Note that if DIP switch #2 on the control board is set to the “on” position, concentrate must be present in order to dispense or program cup sizes. 3. Repeat as necessary for the remaining cup sizes and dispense stations. 4. Exit the “Cup Size Programming” mode by pressing any of the “+/STOP Switches”. Note that the beeper sounds twice and that the “PROGRAM” indicator extinguishes.
Dispenser Lockout Dispense and Rinse functions of the dispenser can be electronically locked-out to prevent unauthorized use of the dispenser, while keeping the refrigeration system running.
1. Enter the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that the beeper sounds twice and that the “PROGRAM” indicator begins flashing. 2. Enter a “Lockout” password as follows: a) Press and hold the left hand “Hidden Switch”. b) In a 5 second period, press and release the “Lock Switch” the number of times that you want the password set to (maximum of 10.) For example: If you want the password set to 3, press and release the “Lock Switch” 3 times in the 5 second period. c) Release the “Hidden Switch”. d) At the end of the 5 second period, the password will be confirmed by the “REFILL” indicators flashing the password. 3. Exit the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that the beeper sounds twice and that the “PROGRAM” indicator extinguishes. 4. To lockout the dispenser, proceed as follows: a) Press and hold either “Hidden Switch”. b) In a 5 second period, press and release the “Lock Switch” the “password” number of times. For example: If the password is set to 3, press and release the “Lock Switch” 3 times in the 5 second period. c) Release the “Hidden Switch”. d) At the end of the 5 second period, the dispenser will extinguish the merchandising lamp, and all dispense functions will be disabled. 5. To enable the dispenser, proceed as follows: a) Press and hold either “Hidden Switch”. b) In a 5 second period, press and release the “Lock Switch” the “password” number of times. For example: If the password is set to 3, press and release the “Lock Switch” 3 times in the 5 second period. c) Release the “Hidden Switch”. d) At the end of the 5 second period, the dispenser will light the merchandising lamp, and dispense functions will be enabled.
35303 012703

ADJUSTMENT & OPTIONAL SETTINGS (cont)
a) Disconnect the dispenser from its power source. b) Place the “Refrigeration Switch” Fig 3, in the OFF (rearward) position. c) While pressing and holding the “Lock Switch”, connect the dispenser to its power source. d) Continue to hold the “Lock Switch” until the dispenser beeps three times, then release. e) The passwords are now returned to “0” (no programming or service lockout password/dispenser lockout disabled.) f) After 3 minutes, place the “Refrigeration Switch” in the ON (forward) position.
Service Lockout Should a dispense station become inoperative and require service, the station’s dispense and rinse functions can be independently locked out, while keeping the remaining stations running.
1. To place a single dispense station in “Service Lockout,” open the dispenser door, press and hold either “Hidden Switch” and the desired dispense station “Product Dispense” (“+/Stop”) switch for 10 seconds. 2. At the end of the 10 second period, the beeper will sound a double tone and the dispense position will be disabled. Place the DISPENSE/RINSE Knob to “DISPINSE” and close the dispenser door. 3. To remove a dispense station from “Service Lockout,” press and hold either “Hidden Switch” and the desired dispense station “Product Dispense” (“+/Stop”) switch for 10 seconds. 4. At the end of the 10 second period, the beeper will sound a double tone and the dispense position will be enabled. Close the dispenser door.
Password Protection The programming modes and service lockout function may be password protected to prevent accidental or unauthorized access to these features. The dispenser is shipped from the factory with a password of “0” (no password.)
1. Enter the “Pump Speed Programming” mode by simultaneously pressing both “Hidden switches”. Note that the beeper sounds twice and that the “PROGRAM” indicator begins flashing. 2. Program a password as follows: a) Press and hold either “Hidden Switch”. b) In a 5 second period, press and release the “Sanitize Switch” the number of times that you want the password set to (maximum of 10.) For example: If you want the password set to 3, press and release the “Sanitize Switch” 3 times in the 5 second period.
c) Release the “Hidden Switch”. d) At the end of the 5 second period, the password will be confirmed by the “WATER” indicators flashing the password. e) From this point forward, the password must be entered before access is allowed to programming modes or the service lockout function.
35303 012703

ADJUSTMENT & OPTIONAL SETTINGS (cont)
3. To enter the password, proceed as follows: a) Press and hold either “Hidden Switch”. b) In a 5 second period, press and release the “Sanitize Switch” the password number of times. For example: If the password is set to 3, press and release the “Sanitize Switch” 3 times in the 5 second period. c) Release the “Hidden Switch”. d) Wait for the password to be confirmed by the flashing of the “Water” indicators. e) Enter the desired program mode or select service lockout as normal within the next 5 seconds.
f) Disconnect the dispenser from its power source. g) Place the “Refrigeration Switch” in the OFF (rearward) position. h) While pressing and holding the “Lock Switch”, connect the dispenser to its power source. i) Continue to hold the “Lock Switch” until the dispenser beeps three times, then release. j) The passwords are now returned to “0” (no programming or service lockout password/dispenser lockout disabled.) k) After 3 minutes, place the “Refrigeration Switch” in the ON (forward) position).
35303 012703

“REFILL” indicator Beeper Fault 2 flashes 2 beeps Dispense station locked out. 3 flashes 3 beeps DISPENSE/RINSE sensing fault. 4 flashes 4 beeps DISPENSE/RINSE knob mis-positioned. 5 flashes 5 beeps Pump motor stalled/speed sensor inoperative. All “REFILL” 3 beeps Dispenser locked out. indicators flash
Fault Code “COOLING” DBC display Fault Fault indicator (optional) Priority 8 8 flashes every fault 8 Bath water level low. 1 5 seconds (Also lights all “WATER” indicators) 7 7 flashes every fault 7 Bath temperature probe short circuit. 2 5 seconds 6 6 flashes every fault 6 Bath temperature probe open circuit. 3 5 seconds 5 5 flashes every fault 5 Cabinet temperature probe short circuit. 4 5 seconds 4 4 flashes every fault 4 Cabinet temperature probe open circuit. 5 5 seconds 3 3 flashes every fault 3 Cooling system failure 6 5 seconds (disables all dispense functions) 0 On steady Bath/cabinet Bath and cabinet temperatures excessive. 7 temperatures 2 2 flashes every Bath/cabinet Bath temperature excessive. 8 5 seconds temperatures 1 1 flash every Bath/cabinet Cabinet temperature excessive. (Disables all 9 5 seconds temperatures dispense functions, flashes, all REFILL and WATER indicators, and sounds the beeper when temperature is excessive for more than 6 hours.)

Dip Switch Function List
Dip Switch Controls Off On 1 “REFILL” indicator when “concentrate out” is detected. Inactive Active 2 Lockout dispense components when “concentrate out” is detected. Inactive Active (Note) 3 Number of positions that can dispense/rinse simultaneously. 3 2 4 Rinse timer Off On 5 Audio feedback during dispenses. On Off 6 Future use. None None Note: When dip switch 2 is in the “on” position, the “REFILL” indicator is active, regardless of dip switch 1 position.
35303 012703

33464.0000A 09/00 ©2000 Bunn-O-Matic Corporation
EVAPORATOR
ACCUMULATOR COMPRESSOR
SUCTION
FILTER
DRYER
CONDENSER
35303 012703


#2 RINSE & DISPENSE LIMIT #1 RINSE & DISPENSE LIMIT
35303 121203


RED
GRY
BLK
BLK
WHI/VIO
GRN
#2 RINSE & DISPENSE LIMIT #1 RINSE & DISPENSE LIMIT
#2 DISPENSE
RED/BLK WHI/VIO
RED/BLK WHI/ORN SOL
SOL
35303 121203