Page 3

USER NOTICES

Carefully read and follow all notices on the equipment and in this manual. They were written for your protec- tion. All notices are to be kept in good condition. Replace any unreadable or damaged labels.

Bunn FCD-4 — USER NOTICES diagram (page 3)
Fig. 2
Bunn FCD-4 — USER NOTICES diagram (page 3)
Fig. 3

DO NOT OVERLOAD CIRCUIT. ALWAYS ELECTRICALLY GROUND THE CHASSIS OR ADAPTOR PLUG. DO NOT DEFORM PLUG OR CORD. FOLLOW NATIONAL AND LOCAL ELECTRICAL CODES. KEEP COMBUSTIBLES AWAY.

BEFORE USING THIS PRODUCT 00986.0002E 5/98 ©1994 Bunn-O-Matic Corporation

27442.0000 00986.0002

Bunn FCD-4 — USER NOTICES diagram (page 3)
Fig. 4

CHARGE Type R134A, Amount 10 oz Design Pressures: High 335 Low 88

33461.0000

MAXIMUM RINSE WATER TEMPERATURE: 170˚F (76.6˚C) Use Bunn-O-Matic tubing, part number 32759.10XX (See Illustrated Parts Catalog for complete part number) for hot water connection.

Hot Water Rinse Connection

Alternate Connection (When Hot Water source is not available)

RINSE WATER CONNECTION

RINSE WATER CONNECTION

Hot Water connection (See Caution)

MAIN WATER CONNECTION

MAIN WATER CONNECTION

3/8" x 3/8" x 3/8" Barb Tee B.O.M. PN 32750.0000 (may be installed internal or external to the dispenser)

NOTES:

  • Use Bunn-O-Matic tubing, part number 32759.10XX for all connections. (See Illustrated Parts Catalog for complete part number)
  • Clamp all hose connections with Bunn-O-Matic part number 21275.0003 (hose clamp)

33648.0000C 01/01 ©2000 BUNN-O-MATIC CORPORATION

33648.0000

Cold Water Connection · Cold Water Connection · 33496 030901

Page 4 of the Bunn FCD-4 user manual — ELECTRICAL REQUIREMENTS
Page 4 · click to enlarge
Page 4

INITIAL SET-UP

1. Set the dispenser on the counter where it will be used. The FCD-4 requires a minimum of 4 inches (102 mm) of air clearance at the rear and 8 inches (203 mm) of air clear- ance above the dispenser. Minimal clearance is required between the dispenser sides and the wall or another appli- ance. For optimum performance, do not let warm air from surrounding machines blow on the FCD-4. Leave some space so the dispenser can be moved for cleaning. 2. Assemble the cup stop in the third slot of the drip tray cover as shown in Fig 1. 3. Place the cover/cup stop assembly on the drip tray and install on the dispenser.

P2264.50

FIG 1 Installing Cup Stop

ELECTRICAL REQUIREMENTS

ELECTRICAL HOOK-UP CAUTION: Improper electrical installation will damage electronic components.

1. An electrician must provide electrical service as specified. 2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source. 3. Connect the dispenser to the power source. 4. If plumbing is to be hooked up later, be sure the dispenser is disconnected from the power source. If plumbing has been hooked up, the dispenser is ready for Initial Fill.

33496 011101

Page 5 of the Bunn FCD-4 user manual — PLUMBING REQUIREMENTS
Page 5 · click to enlarge
Page 5

PLUMBING REQUIREMENTS

This dispenser must be connected to a COLD WATER system with operating pressure between 20 and 100 psi (138 and 690 kPa). This water source must be capable of producing a minimum flow rate of 3 fluid ounces (88.7 milliliters) per second. A shut off valve should be installed in the line before the dispenser. Install a regulator in the line when pressure is greater than 100 psi (690 kPa) to reduce it to 50 psi (345 kPa). The main water inlet is a 3/8” (9.52 mm) barb connection.

Additionally, the dispenser’s rinse connection may be connected to a HOT WATER system. Caution: MAXIMUM RINSE WATER TEMPERATURE: 170 degrees F (76.6 degrees C)

Use BUNN-O-MATIC tubing, part number 32759.10_ _ (see Illustrated Parts Catalog for complete part number) for hot water connection.

The rinse water operating pressure must be between 20 and 100 psi (138 and 690 kPa). A shut off valve should be installed in the line before the dispenser. Install a regulator in the line when pressure is greater than 100 psi (690 kPa) to reduce it to 50 psi (345 kPa). The rinse water inlet is a 3/8” (9.52 mm) barb connection. NOTE- At least 18 inches (457 mm) of an FDA approved flexible beverage tubing, such as reinforced braided polyethylene or silicone, before the dispenser will facilitate movement to clean the countertop. It can be purchased direct from BUNN-O-MATIC (part number 32759.10_ _ [see Illustrated Parts Catalog for com- plete part number.]) BUNN-O-MATIC does not recommend the use of saddle valves to install the dispenser. The size and shape of the hole(s) made in the supply line(s) by saddle valves may restrict water flow.

Bunn FCD-4 — PLUMBING REQUIREMENTS diagram (page 5)
Fig. 5

This equipment must be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).

PLUMBING HOOKUP CAUTION: The dispenser must be disconnected from the power source throughout the plumbing hookup.

Bunn FCD-4 — PLUMBING REQUIREMENTS diagram (page 5)
Fig. 6

All plumbing connections are located behind the dispenser’s splash panel. Water lines may enter the dispenser through the access holes in either the bottom panel or the rear panel of the dispenser. To access plumbing connections: remove the drip tray assembly; remove the two screws securing the splash panel to the dispenser; lower the splash panel from the front of the dispenser. Refer to FIG 2 for proper water hookup.

3/8" x 3/8" x 3/8" Barb Tee B.O.M. PN 32750.0000 (may be installed internal or external to the dispenser)

Alternate Connection (When Hot Water source is not available)

33496 011101

Page 6 of the Bunn FCD-4 user manual — P2263
Page 6 · click to enlarge
Page 6

OPERATING CONTROLS

Bunn FCD-4 — OPERATING CONTROLS diagram (page 6)
Fig. 7

Refrigeration Switch The refrigeration switch is located on the top of the dispenser near the left rear corner. This switch controls power to the compressor and the condenser fan motor.

Sanitize Switch The sanitize switch is located behind the drip tray in the lower left corner of the chassis. The drip tray can be removed to provide easy access to the switch. The sanitize switch is used to enter and exit the sanitize mode and to initiate the sanitize automatic cycle. Refer to Weekly Sanitizing in the Cleaning section for detailed instructions on the use of this switch.

Bunn FCD-4 — OPERATING CONTROLS diagram (page 6)
Fig. 8

B

A

Water Bath and Main Water Valves These valves are manually operated and are located above the drip tray, behind the splash panel. The drip tray and splash panel must be removed to gain access to the valves. The upper (small) one is the water bath valve and the lower (large) one is the main water valve. Refer to the Initial Fill section for detailed instructions on the use of these valves.

P2263

FIG 4 Sanitize Switch & Water Valves

A. Sanitize Switch B. Water Bath Valve C. Main Water Valve

33496 122200

Page 7 of the Bunn FCD-4 user manual — D
Page 7 · click to enlarge
Page 7

OPERATING CONTROLS (cont.)

Bunn FCD-4 — E E E E diagram (page 7)
Fig. 9

FIG 5 Press and Hold Models A. Product Dispense Switch

Pressing and holding switch will initiate product flow from the respective nozzle; releasing the switch will stop the flow. B. Chilled Water Dispense Switch

Pressing and holding switch will initiate chilled water flow from the nozzle; releasing the switch will stop the flow. C. Hidden Switch

These switches are used to access, change and exit the dispenser program mode.

D

E E E E

FIG 6 Portion Control Models B. Chilled Water Dispense Switch

Pressing and holding switch will initiate chilled water flow from the nozzle; releasing the switch will stop the flow. C. Hidden Switch

These switches are used to access, change and exit the dispenser program mode. D. Product Dispense Switch

Momentarily pressing and releasing one of the switches will initiate a timed dispense. Each station has three different timed dispenses which are preset at the factory. Refer to DISPENSER USE section for preset volumes and adjustment procedures. E. Plus/Stop Switch

This switch can be used to “top-off” a beverage. Pressing and holding switch will initiate product flow from the respective nozzle; releasing the switch will stop the flow. Momentarily pressing this switch during a timed dispense will stop the flow.

33496 122200

Page 8 of the Bunn FCD-4 user manual — INITIAL FILL
Page 8 · click to enlarge
Page 8

INITIAL FILL

specified in the instructions. 1. Remove drip tray assembly and splash panel from the dispenser. 2. Pull the overflow tube from its retaining clip and place the end into an empty 64 fluid ounce (2 liter) container. 3. Ensure that the Main Water Valve and the Water Bath Valve Fig 4, are turned off (handles positioned at 6 o’clock and 12 o’clock, respectively,) and that the Refrigeration Switch Fig 3, is in the OFF (rear) position. 4. Turn on the water supply. 5. While observing the water bath sight gauge (the clear tube located just to the left of the plumbing connections,) begin filling the water bath by rotating the handle of the Water Bath Valve counterclockwise to the 9 o’clock position. 6. When the water level in the sight gauge comes within 1 inch (25.4 mm) of the clear plastic tee, reduce the water flow by rotating the handle of the Water Bath Valve clockwise to the 11 o’clock position. 7. When the water in the water bath sight gauge begins to trickle down into the drip tray, turn the Water Bath Valve off by rotating the handle clockwise to the 12 o’clock position. 8. Connect the dispenser to the power source. 9. After approximately 3 minutes (this allows the recirculating pump and cabinet cooling components an opportunity to fill with water,) top off the water bath tank by rotating the handle of the Water Bath Valve counterclockwise to the 11 o’clock position. 10. Again, when the water in the water bath sight gauge begins to trickle down into the drip tray, turn the Water Bath Valve off by rotating the handle clockwise to the 12 o’clock position. 11. Place the Refrigeration Switch ON (forward.) 12. It will take approximately 4 hours at 70 degrees F (21 degrees C) ambient to create the ice bank required for full dispenser performance. During this time, some further trickling from the water bath is expected due to expansion caused by ice bank formation. While the refrigeration system is creating the ice bank, the dispenser may be readied for use as described in Loading, Priming and Adjustment. 13. The dispenser will safely store concentrate once the “COOLING” indicator completely extinguishes (not lit steadily or flashing.) 14. After the refrigeration compressor switches off, turn Main Water Valve on by rotating the handle counterclock- wise to the 3 o’clock position. Secure the overflow tube into its retaining clip and replace the splash panel and drip tray assembly.

LOADING Frozen Concentrates 1. Thaw the frozen concentrate in a refrigerated 35-40 degrees F (1.6-4.4 degrees C) environment for 36 to 48 hours before use. 2. Thoroughly mix the thawed concentrate by vigorously shaking the product container. 3. Open the dispenser door. 4. Prior to placing the product container in the dispenser, make sure that the o-ring on the container adapter is lubricated. This will ease removal of the container when it becomes necessary. 5. Place the product container in the desired position and press it firmly into the bottle adapter opening. 6. Open the vent hole in the product container.

33496 011101

Page 9 of the Bunn FCD-4 user manual — INITIAL FILL
Page 9 · click to enlarge
Page 9

Ambient Concentrates (Optional) 1. Install an Ambient Concentrate Conversion Kit (BUNN-O-MATIC part number 33699.0000) per the instructions provided in the kit. 2. Attach the concentrate product hose to the appropriate concentrate line located behind the dispenser’s splash panel. 3. Attach the other end of the product hose to the product container through an appropriate fitting.

PRIMING 1. Open the dispenser door 2. Load concentrate per instructions in section titled Loading. 3. Close the dispenser door. Note: The dispenser will not operate with the door open. 4. Place a large container under the appropriate dispense nozzle. 5. Dispensers with Press and Hold Feature: Press and hold the “Product Dispense Switch” Fig 5, until concentrate dispenses from the dispense nozzle. Dispensers with Portion Control Feature:

Press and hold the “+/STOP Switch” Fig 6, until concentrate dispenses from the dispense nozzle. Note: This may take several seconds, depending on the installation and programmed pump speed.

INITIAL FILL (cont) · 33496 011101

Page 10 of the Bunn FCD-4 user manual — DISPENSER USE
Page 10 · click to enlarge
Page 10

DISPENSER USE

Press and Hold Models (Refer to Fig 5) 1. Place a cup on the drip tray beneath the desired dispensing nozzle. 2. Press and hold the “Product Dispense” or “Chilled Water” switch until the beverage/water reaches the desired level, then release.

Portion Control Models (Refer to Fig 6) 1. Place a cup on the drip tray beneath the desired dispensing nozzle. 2. Momentarily press the appropriate cup size switch to dispense the beverage. The dispenser is factory preset to produce the approximate beverage sizes as follows:

Small (4.0 seconds): approximately 7 fl.oz. (207 ml) Medium (6.9 seconds): approximately 12 fl.oz. (355 ml) Large (9.1 seconds): approximately 16 fl.oz. (473 ml)

The dispense times can be individually programmed by following the procedures described in ADJUST- MENT - Cup Size Programming.

To stop a timed dispense, momentarily press the “+/Stop Switch”.

3. To “top-off” a beverage, press and hold the “+/Stop Switch” until the beverage reaches the desired level, then release. 4. To dispense chilled water, press and hold the “Chilled Water Switch” until the water reaches the desired level, then release.

33496 011101

Page 11 of the Bunn FCD-4 user manual — CLEANING & PREVENTIVE MAINTENANCE
Page 11 · click to enlarge
Page 11

CLEANING & PREVENTIVE MAINTENANCE

General Cleaning and Sanitizing Procedures Note: The Bunn Juice Dispenser incorporates a rinse reminder feature which lights the rinse led on the front panel

when it is time to rinse. See dip switch function list to activate this feature.

DailyRinse Procedure Tools required: 32 oz. (946 ml) minimum empty container

1. Open the refrigerated compartment’s door to access the “DISPENSE/RINSE” Knobs Fig 7. 2. Select the stations that will be rinsed and then rotate the appropriate Knob(s) to the rinse position. It is recommended that ALL dispense heads be rinsed daily. Note: If a station is in service lockout, leave its knob in the Dispense position. 3. Close the refrigerated compartment’s door. 4. Place the empty container under the dispense nozzle to catch the rinse water. (CAUTION: THE BUNN JUICE DISPENSER CAN BE PLUMBED FOR A HOT WATER RINSE. RINSE WATER CAUGHT

FIG 7 Dispense/Rinse Switch

IN THIS STEP SHOULD BE HANDLED WITH EXTREME CARE.) 5. Press and release the appropriate “Product Dispense Switch” Fig 5. This will initiate a timed rinse cycle. Portion control users can press any of the 3 “Product Dispense Switches” Fig 6, to initiate a timed rinse cycle. 6. Repeat for each dispense head. 7. Open the refrigerated compartment’s door and return each knob to the dispense position. 8. Actuate the station’s Dispense Switch until concentrate appears from the dispense nozzle.

Daily: Parts Washing 1. Remove and wash the dispense nozzle(s), mixing element(s), drip tray, drip tray cover, and cup stop in a mild detergent solution. Rinse thoroughly. 2. Wipe splash panel, areas around dispense nozzle(s), and drip trough in refrigerated compartment with a clean, damp cloth.

Weekly: Sanitizing Tools required: Nozzle tubing (BUNN-O-MATIC part number 03289.1002) recommended when sanitizing multiple dispense heads simultaneously, 1 empty 5 gallon (18.9 L) bucket, 1 packet of Kay 5 sanitizer, and clean, empty concentrate containers.

1. Remove any juice concentrate from the dispenser and store in a separate refrigerated compartment. 2. Perform the rinse procedures as previously described. (Note: If the dispenser is plumbed for hot water rinse, proceed to step 9.) 3. Fill clean empty concentrate container(s) with approximately 32 oz. (946 ml) of the hot tap water (approxi- mately 140°F (60°C). Load the containers of hot water into the dispenser (just like concentrate). Verify the rinse knobs are in the “DISPENSE” position. 4. Remove the drip tray and verify that the nozzle tubes are positioned within the empty bucket. 5. Press and hold the “Sanitize Switch” Fig 4, located on the front left portion of the base, for 5 seconds. The “SANITIZE” indicator on the front panel will begin to flash and the beeper will sound twice indicating that you have entered the sanitize mode. 6. Select the dispense stations by pressing the “Dispense Switch” for that station. Use the “+/Stop Switch” for 33496 030701

Page 12 of the Bunn FCD-4 user manual — CLEANING & PREVENTIVE MAINTENANCE
Page 12 · click to enlarge
Page 12

portion contol dispensers. The “REFILL” indicator will light and the beeper will sound for the dispense head selected. 7. Once the dispense heads have been selected, press and hold the “Sanitize Switch” for 5 seconds again to initiate the automatic cycle. (When the cycle is initiated the “SANITIZE” indicator lights steadily and the “REFILL” indicator for each station being sanitized will flash.)

A) The pumps at the selected dispense heads will run for 1 minute, or until the bottles filled

with hot water empty, whichever occurs first. B) The dispenser will sit idle for 5 minutes. C) The pumps at the selected dispense heads will run for 2 minutes or until the bottles filled

with hot water empty, whichever occurs first. D) The beeper will sound once every 3 seconds to indicate completion of the sanitize

routine.

8. Once the cycle is completed, disconnect the sanitizing hose(s) from the nozzle(s) and empty the bucket. 9. Remove each dispense nozzle and mixing element and run under hot tap water to remove excess pulp. 10. Prepare 2.5 gal. (9.46 L) of sanitizing solution by dissolving 1 packet of Kay 5 sanitizer into 2.5 gal. (9.46 L) of 120°F (48.9°C) water to ensure 100 ppm of available chlorine. 11. Place nozzle(s) and mixing element(s) in a separate 1 quart container of sanitizing solution and mix thoroughly. Allow the part to soak for 2 minutes. 12. Clean the dispense nozzle receptacle(s) (dispense valves) with the sanitizing solution and a soft bristle brush. 13. Clean the concentrate bottle’s inlet adapter(s) using the sanitizing solution and a soft bristle brush. 14. Replace the mixing element(s) and nozzle(s), reattach the sanitizing hose(s) to the nozzle(s), and insert the hoses into the catch bucket. 15. Fill approximately 64 ounces (1.89 L) of clean sanitizing solution into clean, empty concentrate container(s). Do not use the sanitizing solution used in step 11. Load the containers into the dispenser. 16. Repeat steps 5 through 8.

A) The pumps at the selected dispense heads will run for 1 minute, or until the bottles filled

with sanitizing solution empty, whichever occurs first. B) The dispenser will sit idle for 5 minutes. C) The pumps at the selected dispense heads will run for 2 minutes or until the bottles filled

with sanitizing solution empty, whichever occurs first. D) The beeper will sound once every 3 seconds to indicate completion of the sanitize

routine.

17. Replace the sanitizing solution with concentrate and reattach the drip tray. 18. Activate a rinse cycle at each station as described in DAILY RINSE PROCEDURE. 19. At each station, actuate the Dispense Switch until juice appears. Then pour one 12 ounce (354.9 ml) glass of juice and discard. 20. Wipe internal and external surfaces with a clean, damp cloth.

CLEANING (cont) · 33496 030901

Page 13 of the Bunn FCD-4 user manual — CLEANING & PREVENTIVE MAINTENANCE
Page 13 · click to enlarge
Page 13

Monthly: Clean Condenser Air Filter 1. Remove the condenser air filter located on the rear of the dispenser. 2. Using a water spray, clean the air filter.

Annually: Replace Pump Tubing 1. Open dispenser door. 2. Remove all product containers and place them in a refrigerated (35-40 degrees F [1.6-4.4 degrees C]) environment. Disconnect all connections to ambient products from the bottle adapter. 3. Close the dispenser door and dispense product at each station until the product runs clear. 4. Remove the drip tray assembly and splash panel from the dispenser. 5. Replace the drip tray assembly. 6. Turn the Main Water valve to the 6 o’clock position. 7. Open the dispenser door and remove the product shelf. 8. Remove the DISPENSE/RINSE knobs Fig 7, all dispense nozzles, the 2 screws securing the cover to the dispense platform, and the cover. 9. Disconnect the dispense platform’s water lines from the supply lines inside the refrigerated cabinet and disconnect the wiring connections from the cabinet receptacles. 10. Remove the 2 thumb-screws securing the dispense platform to the cabinet . 11. Slowly pull the dispense platform forward to allow access to the rear wiring harness connector. 12. Disconnect the rear wiring harness connector from its receptacle. 13. Pull the dispense platform completely out of the cabinet and place it on a flat work surface. 14. Close the dispenser door. 15. Remove the screw securing the tubing retainer plate to the pump body and set it and the tubing retainer plate aside. 16. Gently pull the socket head screw from its notch in the pump body, releasing the spring tension on the pump band. 17. Gently pull the pump tube from around the pump’s rotor. 18. Inspect the pump band for signs of wear. Replace if necessary. 19. Release the clamps securing the old pump tubing to the plastic elbows. 20. Pull the plastic elbows from the old pump tubing, and discard the old pump tubing. 21. Insert the plastic elbows into the new pump tubing and secure it with the clamps. 22. Apply lubricant (BUNN-O-MATIC part number M2548.0000) to the new pump tubing’s rotor side. 23. Gently wrap the new pump tubing around the pump’s rotor, making sure that the elbows and clamps end up on the top-side of the pump body and don’t protrude through the exit slots. 24. Replace the socket-head screw into its notch in the pump body. 25. Replace the tubing retainer plate and its retaining screw. 26. Repeat steps 15 through 24 for the remaining pumps. 27. Replace the dispense platform into the refrigerated cabinet, making sure to reconnect all electrical and water connections. 28. Turn the Main Water Valve to the 3 o’clock position. Check for leaks. 29. Replace the thumb-screws, cover, cover screws, DISPENSE/RINSE knobs and dispense nozzles. 30. Turn all DISPENSE/RINSE knobs to the RINSE positions. Close the door and run a rinse at each station. Check for leaks. 31. Replace product shelf and product containers. Reconnect any connections to ambient product containers. 32. Prime the pumps as described in “PRIMING” in the Initial Fill Section.

CLEANING (cont) · 33496 030901

Page 14 of the Bunn FCD-4 user manual — ADJUSTMENT & OPTIONAL SETTINGS
Page 14 · click to enlarge
Page 14

ADJUSTMENT & OPTIONAL SETTINGS

SETTING THE MIX RATIO/BRIX Ratio Cup Method 1. Adjust the water flow as described in Water Flow Testing and Adjustment. 2. Remove the dispense nozzle from the appropriate dispense position. 3. Assemble, lubricate, and install the Flow Separator Assembly (BUNN-O-MATIC part number 32629.0000) into the dispense nozzle receptacle (dispense valve,) making sure to point the arrow on the separator body away from the dispenser. 4. Place an empty container under the Flow Separator Assembly. 5. Dispensers with Press and Hold Feature: Press and hold the “Product Dispense Switch” Fig 5, until water and concentrate begin flowing freely from the Flow Separator Assembly nozzles. Dispensers with Portion Control Feature:

Press and hold the “+/Stop Switch” Fig 6, until water and concentrate begin flowing freely from the Flow Separator Assembly nozzles. 6. Place the empty brixing cup (BUNN-O-MATIC part number 33095.0000) under the Flow Separator Assembly nozzles, small (concentrate) chamber to the left and large (water) chamber to the right. 7. Dispensers with Press and Hold Feature: Press and hold the “Product Dispense Switch” until concentrate reaches the 1 oz. (black line) mark. Dispensers with Portion Control Feature:

Press and hold the “+/Stop Switch” until concentrate reaches the 1 oz. (black line) mark. 8. Read the level in the water chamber. This reading directly determines the mix ratio (i.e. If the water level reads 4.0 oz., then the mix ratio is 4 [water] + 1 [concentrate].) 9. Adjust the pump speed (down to increase the ratio, up to decrease the ratio) to achieve the correct mix ratio as described in Pump Speed Programming. 10. Remove the Flow Separator Assembly and replace the dispense nozzle assembly into the dispense nozzle receptacle (dispense valve.)

Temperature Compensated Refractometer Method 1. Adjust the water flow as described in Water Flow Testing and Adjustment. 2. Place an empty container under the appropriate dispense nozzle. 3. Dispensers with Press and Hold Feature: Press and hold the “Product Dispense Switch” Fig 5, until water and concentrate begin flowing freely from the dispense nozzle. Dispensers with Portion Control Feature:

Press and hold the “+/Stop Switch” Fig 6, until water and concentrate begin flowing freely from the dispense nozzle. 4. Discard the product caught previously and place the empty container back under the dispense nozzle. 5. Dispensers with Press and Hold Feature: Press and hold the “Product Dispense Switch” until the cup is filled. Dispensers with Portion Control Feature:

Press and hold the “+/Stop Switch” until the cup is filled. 6. Stir the contents of the cup, and use the refractometer (according to the manufacturer’s instructions) to check the brix %. 7. Adjust the pump speed (down to decrease the brix %; up to increase the brix %) to achieve the correct brix % as described in Pump Speed Programming.

33496 011101

Page 15 of the Bunn FCD-4 user manual — P2253.70
Page 15 · click to enlarge
Page 15

ADJUSTMENT & OPTIONAL SETTINGS (cont)

Water Flow Testing and Adjustment 1. Enter the “Pump Speed Programming” mode by simultaneously press- ing both “Hidden Switches” Fig 5 or Fig 6. Note that the beeper sounds twice and that the “PROGRAM” indicator begins flashing. 2. Place a graduated measuring cup or the large chamber of the empty brixing cup (BUNN-O-MATIC part number 33095.0000) under the appropriate dispense nozzle. 3. Press and hold the desired “Product Dispense Switch” Fig 5 (“+/Stop Switch” Fig 6, for portion control dispensers) for 5 seconds. Note that the beeper sounds once per second (6 times, total) during this period. 4. At the end of the 5 second period, the selected position will dispense water (no concentrate) for only 3 seconds. 5. Measure the water dispensed. 6. Adjust the water flow rate Fig 8, (clockwise to increase flow rate; counterclockwise to decrease flow rate) to the corresponding product mix ratio as follows:

P2253.70

FIG 8 Adjusting Water Flow

Mix Ratio Adjust water flow rate to: Product Brix % (water + concentrate)

2+1 3.75 fluid ounces (111 ml) Prune Juice 16.0% per 3-second test Other * Orange Juice 11.8% 4+1 Pineapple Juice 12.8% Cranberry Fruit Cocktail 14.0% 4.5 fluid ounces (133 ml) Grapefruit Juice 10.6% per 3-second test Lemonade 5+1 Apple Juice 12.0% Fruit Punch Grape Juice 13.0% 3+1 through 7+1 Other * Above 7+1 6.0 fluid ounces (177 ml) Other * per 3-second test Note: Information for specific products listed in this table is to be used for reference only. Consult the product label for exact mix ratio and/or brix %. See product label for target brix %.

7. Repeat steps 3 through 6 as necessary until the correct water flow rate is achieved. 8. Repeat steps 3 through 7 for the remaining dispense positions. 9. Exit the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that the beeper sounds twice and the “PROGRAM” indicator extinguishes.

Pump Speed Programming 1. Enter the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that the beeper sounds twice and that the “PROGRAM” indicator begins flashing. 2. To increase the pump speed, press and hold the right-hand “Hidden Switch” (filled circle) and then momentarily press the “Product Dispense Switch” Fig 5 (“+/STOP Switch” Fig 6, for portion control dispensers). Each time the “Product Dispense Switch “(+/STOP Switch”) is pressed, the motor speed is increased by one step (5 revolutions per minute [RPM].) Note that each step is confirmed by a single flash of the appropriate “REFILL” indicator and a single tone from the beeper. 3. To decrease the pump speed, press and hold the left-hand “Hidden Switch” (half-filled circle) and then momentarily press the “Product Dispense Switch (“+/STOP Switch” for portion control dispensers). Each time the “Product Dispense” (“+/STOP”) Switch is pressed, the motor speed is decreased by one step (5 RPM.) Note

33496 011101

Page 16 of the Bunn FCD-4 user manual — P2263
Page 16 · click to enlarge
Page 16

ADJUSTMENT & OPTIONAL SETTINGS (cont)

that each step is confirmed by a single flash of the appropriate “REFILL” indicator and a single tone from the beeper. 4. Repeat as necessary at the remaining dispense stations. 5. Exit the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that the beeper sounds twice and that the “PROGRAM” indicator extinguishes.

Chilled Water Flow Testing and Adjustment 1. Enter the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that the beeper sounds twice and that the “PROGRAM” indicator begins flashing. 2. Place a graduated measuring cup or the large chamber of the empty brixing cup (BUNN-O-MATIC part number 33095.0000) under the appropriate dispense nozzle. 3. Press and hold the “Chilled Water Switch” Fig 5 or Fig 6, for 5 seconds. Note that the beeper sounds once per second (6 times, total) during this period. 4. At the end of the 5 second period, the chilled water will dispense for 3 seconds. 5. Measure the water dispensed. (Approx. 4.5 fl. oz. [133 ml]) 6. If adjustment is required, remove all concentrate bottles from dispenser and disconnect any optional ambient concentrate hoses. Remove product shelf from dispenser. 7. Adjust the Chilled Water Flow Valve Fig 9, clockwise to decrease flow rate; counterclockwise to increase flow rate. 8. Repeat steps 3 through 6 as necessary until the desired water flow rate is achieved. 9. Exit the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that the beeper sounds twice and that the “PROGRAM” indicator extinguishes.

Bunn FCD-4 — P2253.70 diagram (page 16)
Fig. 10

P2263

FIG 9 Chilled Water Flow Valve

Cup Size Programming (Portion Control Dispensers Only) 1. Enter the “Cup Size Programming” mode by simultaneously pressing the “LARGE” and “SMALL” cup size switches at any dispense station. Note that the beeper sounds twice and that the “PROGRAM” indicator lights steadily. 2. Press and hold the desired cup size switch at the appropriate dispense position until the correct cup volume is achieved. Top up as necessary by momentarily pressing the same cup size switch. Note that if DIP switch #2 on the control board is set to the “on” position, concentrate must be present in order to dispense or program cup sizes. 3. Repeat as necessary for the remaining cup sizes and dispense stations. 4. Exit the “Pump Speed Programming” mode by pressing any of the “+/STOP Switches”. Note that the beeper sounds twice and that the “PROGRAM” indicator extinguishes.

Dispenser Lockout Dispense and Rinse functions of the dispenser can be electronically locked-out to prevent unauthorized use of the dispenser, while keeping the refrigeration system running.

1. Enter the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that the beeper sounds twice and that the “PROGRAM” indicator begins flashing. 2. Enter a “Lockout” password as follows: a) Press and hold either “Hidden Switch”.

33496 011101

Page 17 of the Bunn FCD-4 user manual — P2253.70
Page 17 · click to enlarge
Page 17

ADJUSTMENT & OPTIONAL SETTINGS (cont)

b) In a 5 second period, press and release the “Chilled Water Switch” the number of times that you want the password set to (maximum of 10.) For example: If you want the password set to 3, press and release the “Chilled Water Switch” 3 times in the 5 second period. c) Release the “Hidden Switch”. d) At the end of the 5 second period, the password will be confirmed by the “REFILL” indicators flashing the password. 3. Exit the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that the beeper sounds twice and that the “PROGRAM” indicator extinguishes. 4. To lockout the dispenser, proceed as follows: a) Press and hold either “Hidden Switch”. b) In a 5 second period, press and release the “Chilled Water Switch” the “password” number of times. For example: If the password is set to 3, press and release the “Chilled Water Switch” 3 times in the 5 second period. c) Release the “Hidden Switch”. d) At the end of the 5 second period, the dispenser will extinguish the merchandising lamp, and all dispense functions will be disabled. 5. To enable the dispenser, proceed as follows: a) Press and hold either “Hidden Switch”. b) In a 5 second period, press and release the “Chilled Water Switch” the “password” number of times. For example: If the password is set to 3, press and release the “Chilled Water Switch” 3 times in the 5 second period. c) Release the “Hidden Switch”. d) At the end of the 5 second period, the dispenser will light the merchandising lamp, and dispense functions will be enabled. 6. If the password is forgotten, it can be reset to “0” (dispenser lockout disabled) as follows:

a) Disconnect the dispenser from its power source. b) Place the “Refrigeration Switch” Fig 3, in the OFF (reward) position. c) While pressing and holding the “Chilled Water Switch”, connect the dispenser to its power source. d) Continue to hold the “Chilled Water Switch” until the dispenser beeps three times, then release. e) The passwords are now returned to “0” (no programming or service lockout password/dispenser lockout disabled.) f) After 3 minutes, place the “Refrigeration Switch” in the ON (forward) position.

Service Lockout Should a dispense station become inoperative and require service, the station’s dispense and rinse functions can be independently locked out, while keeping the remaining stations running.

1. To place a single dispense station in “Service Lockout,” open the dispenser door, press and hold either “Hidden Switch” and the desired dispense station “Product Dispense” (“+/Stop”) switch for 10 seconds. 2. At the end of the 10 second period, the beeper will sound a double tone and the dispense position will be disabled. Place the DISPENSE/RINSE Knob to “DISPINSE” and close the dispenser door. 3. To remove a dispense station from “Service Lockout,” open the dispenser door, press and hold either “Hidden Switch” and the desired dispense station “Product Dispense” (“+/Stop”) switch for 10 seconds. 4. At the end of the 10 second period, the beeper will sound a double tone and the dispense position will be enabled. Close the dispenser door.

33496 011101

Page 18 of the Bunn FCD-4 user manual — P2253.70
Page 18 · click to enlarge
Page 18

ADJUSTMENT & OPTIONAL SETTINGS (cont)

Password Protection The programming modes and service lockout function may be password protected to prevent accidental or unauthorized access to these features. The dispenser is shipped from the factory with a password of “0” (no password.)

1. Enter the “Pump Speed Programming” mode by simultaneously pressing both “Hidden switches”. Note that the beeper sounds twice and that the “PROGRAM” indicator begins flashing. 2. Program a password as follows: a) Press and hold either “Hidden Switch”. b) In a 5 second period, press and release the “Sanitize Switch” the number of times that you want the password set to (maximum of 10.) For example: If you want the password set to 3, press and release the “Sanitize Switch” 3 times in the 5 second period.

c) Release the “Hidden Switch”. d) At the end of the 5 second period, the password will be confirmed by the “WATER” indicators flashing the password. e) From this point forward, the password must be entered before access is allowed to programming modes or the service lockout function. 3. To enter the password, proceed as follows: a) Press and hold either “Hidden Switch”. b) In a 5 second period, press and release the “Sanitize Switch” the password number of times. For example: If the password is set to 3, press and release the “Sanitize Switch” 3 times in the 5 second period. c) Release the “Hidden Switch”. d) Wait for the password to be confirmed by the flashing of the “Water” indicators. e) Enter the desired program mode or select service lockout as normal within the next 5 seconds.

4. If the password is forgotten, it can be reset to “0” (no password) as follows:

f) Disconnect the dispenser from its power source. g) Place the “Refrigeration Switch” in the OFF (rearward) position. h) While pressing and holding the “Chilled Water Switch”, connect the dispenser to its power source. i) Continue to hold the “Chilled Water Switch” until the dispenser beeps three times, then release. j) The passwords are now returned to “0” (no programming or service lockout password/dispenser lockout disabled.) k) After 3 minutes, place the “Refrigeration Switch” in the ON (forward) position).

33496 011101

Page 19 of the Bunn FCD-4 user manual — P2253.70
Page 19 · click to enlarge
Page 19

“REFILL” indicator Beeper Fault 2 flashes 2 beeps Dispense station locked out. 3 flashes 3 beeps DISPENSE/RINSE sensing fault. 4 flashes 4 beeps DISPENSE/RINSE knob mis-positioned. 5 flashes 5 beeps Pump motor stalled/speed sensor inoperative. All “REFILL” 3 beeps Dispenser locked out. indicators flash

Fault Code “COOLING” DBC display Fault Fault indicator (optional) Priority 8 8 flashes every fault 8 Bath water level low. 1 5 seconds (Also lights all “WATER” indicators) 7 7 flashes every fault 7 Bath temperature probe short circuit. 2 5 seconds 6 6 flashes every fault 6 Bath temperature probe open circuit. 3 5 seconds 5 5 flashes every fault 5 Cabinet temperature probe short circuit. 4 5 seconds 4 4 flashes every fault 4 Cabinet temperature probe open circuit. 5 5 seconds 3 3 flashes every fault 3 Cooling system failure 6 5 seconds (disables all dispense functions) 0 On steady Bath/cabinet Bath and cabinet temperatures excessive. 7 temperatures 2 2 flashes every Bath/cabinet Bath temperature excessive. 8 5 seconds temperatures 1 1 flash every Bath/cabinet Cabinet temperature excessive. 9 5 seconds temperatures

Dip Switch Function List

Dip Switch Controls Off On 1 “REFILL” indicator when “concentrate out” is detected. Inactive Active 2 Lockout dispense components when “concentrate out” is detected. Inactive Active (Note) 3 Number of positions that can dispense/rinse simultaneously. 3 2 4 Rinse timer Off On 5 Audio feedback during dispenses. On Off 6 Future use. None None Note: When dip switch 2 is in the “on” position, the “REFILL” indicator is active, regardless of dip switch 1 position.

Show 4 more labels / short text on this page
Dispense Fault List · 3 times · Cooling Fault List · 33496 030901
Page 20 of the Bunn FCD-4 user manual — PROCESS TUBE
Page 20 · click to enlarge
Page 20

COOLANT SCHEMATIC DIAGRAM

33464.0000A 09/00 ©2000 Bunn-O-Matic Corporation

PROCESS TUBE

EVAPORATOR

ACCUMULATOR COMPRESSOR

SUCTION

FILTER

DRYER

CONDENSER

33496 011101

Page 21 of the Bunn FCD-4 user manual — N L1
Page 21 · click to enlarge
Page 21

SCHEMATIC WIRING DIAGRAM

N L1

GRN

Bunn FCD-4 — N L1 diagram (page 21)
Fig. 11

SPEED SENSOR #1 SPEED SENSOR #2 SPEED SENSOR #3 SPEED SENSOR #4

#3 RINSE & DISPENSE LIMIT #1 RINSE & DISPENSE LIMIT

#4 RINSE & DISPENSE LIMIT #2 RINSE & DISPENSE LIMIT

33496 011101

Ask about the Bunn FCD-4

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Bunn FCD-4

Be the first to ask — other owners or our team will answer.

Original document

Bunn FCD-4 manual PDF

21 pages·522 KB·Beverage Dispenser·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…