BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644
To ensure you have the latest revision of the manual or to obtain the illustrated parts catalog, please visit the Bunn-O-Matic website, at www.bunn.com This is absolutely FREE, and the quickest way to obtain the latest catalog and manual updates. Contact Bunn-O-Matic Corporation at 1-800-286-6070 to obtain a paper copy of the required Illustrated Parts Catalog mailed via U.S. Postal Service.

BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCP/MCA pod brewers thermal servers and Thermofresh servers (mechanical and digital)- 1 year parts and 1 year labor. 2) All other equipment - 2 years parts and 1 year labor plus added warranties as specified below: a) Electronic circuit and/or control boards - parts and labor for 3 years. b) Compressors on refrigeration equipment - 5 years parts and 1 year labor. c) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis - parts and labor for 4 years or 40,000 pounds of coffee, whichever comes first.
These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect, alteration, improper installation or operation, improper maintenance or repair, non periodic cleaning and descaling, equipment failures related to poor water quality, damage or casualty. In addition, the warranty does not apply to replacement of items subject to normal use including but not limited to user replaceable parts such as seals and gaskets. This warranty is conditioned on the Buyer 1) giving BUNN prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Office Box 3227, Springfield, Illinois 62708-3227; 2) if requested by BUNN, shipping the defective equipment prepaid to an authorized BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under warranty. THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EX- PRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make modifications to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and should not be relied upon. If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive op- tion while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during the applicable parts and labor warranty periods specified above) to repair the defective components, provided that this repair is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase price for the equipment. THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND. In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.
392, A Partner You Can Count On, Air Infusion, AutoPOD, AXIOM, BrewLOGIC, BrewMETER, Brew Better Not Bitter, Brew- WISE, BrewWIZARD, BUNN Espress, BUNN Family Gourmet, BUNN Gourmet, BUNN Pour-O-Matic, BUNN, BUNN with the stylized red line, BUNNlink, Bunn-OMatic, Bunn-O-Matic, BUNNserve, BUNNSERVE with the stylized wrench design, Cool Froth, DBC, Dr. Brew stylized Dr. design, Dual, Easy Pour, EasyClear, EasyGard, FlavorGard, Gourmet Ice, Gourmet Juice, High Intensity, iMIX, Infusion Series, Intellisteam, My Café, Phase Brew, PowerLogic, Quality Beverage Equipment Worldwide, Respect Earth, Respect Earth with the stylized leaf and coffee cherry design, Safety-Fresh, savemycoffee.com, Scale-Pro, Silver Series, Single, Smart Funnel, Smart Hopper, SmartWAVE, Soft Heat, SplashGard, The Mark of Quality in Beverage Equipment Worldwide, ThermoFresh, Titan, trifecta, Velocity Brew, Air Brew, Beverage Bar Creator, Beverage Profit Calculator, Brew better, not bitter., BUNNSource, Coffee At Its Best, Cyclonic Heating System, Daypart, Digital Brew- er Control, Element, Milk Texturing Fusion, Nothing Brews Like a BUNN, Pouring Profits, Signature Series, Sure Tamp, Tea At Its Best, The Horizontal Red Line, Ultra are either trademarks or registered trademarks of Bunn-O-Matic Corporation. The commercial trifecta® brewer housing configuration is a trademark of Bunn-O-Matic Corporation.
2 42311 070913


A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department.
When a fault occurs (failure to the unit) the POWER lamp will
flash to identify the problem (early models)
Flashes Description of Failure 1 Temperature Sensor (short) 2 Temperature Sensor (open) 3 Refill Fault (continuous refill for 15 minutes) 4 Heater Fault (heater relay on for 120 minutes) 5 Boil Thermistor (short) H5X/H10X only 6 Boil Thermistor (open) H5X/H10X only
Er1 Temperature Sensor (short) Er2 Temperature Sensor (open) Er3 Refill Fault (continuous refill for 15 minutes) Er4 Heater Fault (heater relay on for 120 minutes) Er5 Boil Thermistor (short) H5X/H10X only) Er6 Boil Thermistor (open) H5X/H10X only)
Remedy
Problem
Equipment will not operate.
(A) Check the terminal block for the cor- rect voltage. It should be: a.) 100 to 120 volts ac across the black and white terminals for 100 to 120 volt models or, b.) 200 to 240 volts ac across the red and black terminals for 200 to 240 volt models or, c.) 230 volts ac across the red and black terminals for 230 volt models.
(B) Check circuit breakers or fuses.
42311 071310

Problem Probable Cause Remedy
Equipment will not operate (cont.)
Refer to Service – safety overflow switch for testing procedures.
Automatic refill will not oper- ate after drawing hot water.
Check plumbing and shut-off valves.
(A) Direction of flow arrow must be point- ing towards dispenser.
(B) Remove the strainer/flow control and check for obstructions. Clear or replace.
Refer to Service – electronic controls for testing procedures.
Refer to Service – solenoid valve for test- ing procedures.
Water flows into the tank con- tinuously (Dispenser discon- nected from power source).
Refer to Service – solenoid valve for test- ing procedures.
Water flows into the tank con- tinuously (Dispenser connect- ed to power source).
Refer to Service – electronic controls for testing procedures.
Water is cold.
Refer to Service – safety overflow switch for testing procedures.
Refer to Service – limit thermostat for testing procedures.
Refer to Service – tank heater for testing procedures.
Refer to Service – electronic controls for testing procedures.
42311 071310

Problem Probable Cause Remedy
Water boils continuously.
Refer to Service – electronic controls for testing procedures.
Inspect the tank assembliy for excess lime deposits. Delime as required.
Dispenser is making unusual noises.
Plumbing lines should not be resting on the counter top.
(A) The dispenser must be connected to a cold water line.
(B) Water pressure to the dispenser must not be higher than 90 psi (620 kPa). Install a regulator if necessary to lower the work- ing pressure to approximately 50 psi (345 kPa).
Ready indicator will not light.
Refer to Service – electronic controls for testing procedures.
Replace the indicator LED.
42311 071310

WARNING – Disconnect the dispenser from the power source before the removal of any panel or the replacement of any component. WARNING - Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel. Disconnect the dispenser fromthe power source when servicing, except when electrical tests are required and the test procedure specifically states to connect the dispenser to the power source.


The check valve, electronic control assembly, safety overflow switch, solenoid valve, overflow tube tempera- ture sensor and terminal block are located at the rear of the dispenser. Access is gained by removing the upper and lower rear panels. The upper is attached with six 8-32 slotted-head screws. The lower is attached with four 8-32 slotted-head screws. The middle panel must not be removed from the dispenser.
@ The check valve, electronic control assembly, over- flow protection switch, solenoid valve, overflow tube temperature sensor, triac assembly (EARLY MODELS ONLY) and terminal block are located on the side of the dispenser. Access is gained by removing the side panel. The panel is attached with eight 8-32 slotted- head screws.

Faceplate Removal - H5 ELEMENT: After removing top cover, remove the two upper screws securing the faceplate. Carefully lift faceplate straight up until the three lower screws clear the key holes.
42311 022311

Liquid Level Control Flow Charts



BUNN 90 psig max operating pressure Strainer/Flow Control # 22300.0750 (Repl. Flow Washer #20526.0750) (Repl. Screen #23721.0000)
Location:
The electronic control board is located inside the rear of the dispenser. Access will also be needed to the temperature sensor, overflow tube temperature sensor, and liquid level probe located on the tank lid.
General:
This system controls the liquid level and water temperature of the dispenser. These two functions act independently of each other and should be tested separately.
42311 071310

4. Remove the pink wire from terminal 5 of the elec- tronic control assembly. 5. Check the voltage across terminals 1 & 4 of the electronic control board with a voltmeter. Connect the dispenser to the power source. The indication must be: a.) 100 to 120 volts ac for 100 to 120 voltmodels or b.) 200 to 240 volts ac for 200 to 240 volt models or c.) 230 volts ac for 230 volt models after a delay of approximately 5 seconds. 6. Disconnect the dispenser from the power source.
Liquid Level Control Test Procedure
1. Disconnect the dispenser from the power source. 2. Check the voltage across terminals 3 & 4 of the electronic control board with a voltmeter. Connect the dispenser to the power source. The indication must be: a.) 100 to 120 volts ac for 100 to 120 volt models or b.) 200 to 240 volts ac for 200 to 240 volt models or c.) 230 volts ac for 230 volt models. 3. Disconnect the dispenser from the power source. If voltage was present as described, proceed to #4. If voltage was not present as described, refer to the Wiring Diagrams and check the dispenser wiring harness.
If voltage was present as described, the liquid level con- trol of the system is operating properly, proceed to #7. If voltage was not present as described, replace the electronic control board and the temperature sensor in the tank lid.
SERVICE (cont.) Temperature Control Flow Charts


42311 071310

7. Reconnect the pink wire to terminal 5 of the elec- tronic control assembly. 8. Loosen the compression fitting, remove the probe from the tank lid, and inspect it for mineral depos- its. Replace it if necessary. Keep the exposed ends of the probe away from any metal surface of the dispenser. 9. Check the voltage across terminals 1 & 4 of the elec- tronic control assembly with a voltmeter. Connect the dispenser to the power source. The indication must be: a.) 100 to 120 volts ac for 100 to 120 volt models or b.) 200 to 240 volts ac for 200 to 240 volt models or c.) 230 volts ac for 230 volt models after a delay of approximately 5 seconds. 10. Touch the screw head end of the probe to the dis- penser housing. The indication must be 0. 11. Move the probe away from the dispenser housing. The indication must again be: a.) 100 to 120 volts ac for 100 to 120 volt models or b.) 200 to 240 volts ac for 200 to 240 volt models or c.) 230 volts ac for 230 volt models after a delay of approximately 5 seconds. 12. Disconnect the dispenser from the power source.
If voltage was not present as described, check the pink probe wire and the green ground wire for continuity and/or replace the probe.
Temperature Control Test Procedure
1. Disconnect the dispenser from the power source. 2. Check the voltage across terminals 3 & 4 of the electronic control circuit board with a voltmeter. Connect the dispenser to the power source.The indication must be: a.) 100 to 120 volts ac for 100 to 120 volt models or b.) 200 to 240 volts ac for 200 to 240 volt models or c.) 230 volts ac for 230 volt models. 3. Disconnect the dispenser from the power source. 4. Check the voltage across the tank heater terminals with a voltmeter. Connect the dispenser to the power source. The indication must be: a.) 100 to 120 volts ac for 100 to 120 volt models or b.) 200 to 240 volts ac for 200 to 240 volt models or c.) 230 volts ac for 230 volt models. 5. Disconnect the dispenser from the power source.
Temperature Control Flow Charts (cont.)
If voltage was present as described, reinstall the probe, the sensing function of the system is operating properly.
H5X THERMOSTAT
Red Light On While
Red Light On While
Disconnect Blue Wire From
Disconnect Blue Wire From
Control Board Pin 7
Control Board Pin 7


If voltage was present as described, the temperature control of the system is operating properly. If voltage was not present as described, contact Bunn-O-Matic to order an electronic control board and temperature sensor for evaluation and proceed to #9.
T3 BLK to Overflow Safety Switch T2 GRN or GRN/YEL to Chassis Ground
If voltage was present as described, the temperature control of the system is operating properly. Return the new electronic control board or temperature sensor to Bunn-O-Matic for credit.
J3 PNK & GRY to Heater Indicator Refill Indicator Power Indicator Ready Indicator
Electronic Controls Removal and Replacement
1. Remove all wires from the electronic control board terminals. 2. Remove the six 6-32 screws holding the electronic control board to the component bracket. 3. Disconnect the temperature sensor, overflow tube temperature sensor, and indicator wires from the electronic control board. 4. Attach the temperature sensor, overflow tube temperature sensor, and indicator wires to the electronic control assembly. 5. Fasten the new electronic control board to its bracket. 6. Refer to Fig 2 when reconnecting the wires. 7. Review the initial set-up procedures on page 6.
The H5X/H10X dispensers hold the water tempera- ture at the threshold of boiling. It is not adjustable by the user. The H5E dispenser is factory calibrated for the temperature specified on the data plate. If adjustment is required, use the following procedure:
Adjustments · 42311 071310

If voltage was present as described, reconnect the black wire and proceed to #5. If voltage was not present as described, refer to the Wir- ing Diagrams and check the dispenser wiring harness.
Limit Thermostat Location: The limit thermostat is located on the tank lid. To test the limit thermostat, access will also be needed to the terminal block located at the rear of the dispenser.

If continuity is not present as described, the circuit is broken. Press the reset button of the limit thermostat and recheck for continuity. If continuity is not present as described, replace the limit thermostat.
Removal and Replacement: 1. Remove both wires from the limit thermostat ter- minals. 2. Remove the two #10-32 nuts attaching the limit thermostat to the top of the tank. 3. Install the new limit thermostat and secure into place with two #10-32 nuts. 4. Refer to FIG. 4 when reconnecting the wires.

Test Procedure: 1. Disconnect the dispenser from the power source. 2. There are two black wires on the limit thermostat terminals. One comes from the terminal block. The other goes directly to the tank heater terminal. Re- move the black wire at the limit thermostat coming from the terminal block. 3. Check the voltage across the black wire removed from the limit thermostat and the white wire or red wire of the terminal block with a voltmeter. Connect the dispenser to the power source. The indication must be: a.) 100 to 120 volts ac for 100 to 120 volt models or b.) 200 to 240 volts ac for 200 to 240 volt models or c.) 230 volts ac for 230 volt models. 4. Disconnect the dispenser from the power source.
42311 071310


Removal and Replacement: 1. Disconnect the black wires from the safety overflow switch. 2. Remove the nut beneath the copper overflow cup. 3. Remove the entire switch assembly from the cup. 4. Place the new switch assembly into the cup, wires first. Make sure that a gasket is in place around the threaded switch stem.

Location: The safety overflow switch is located inside the rear of the dispenser inside the copper overflow cup. For testing or removal of the safety overflow switch, access may also be needed by removing the two screws attaching the electronic control assembly to its mount- ing bracket.
Test Procedure: 1. Once voltage is verified at the power source, check for continuity across the safety overflow switch red wires only until the plastic float is raised and check that continuity returns when the plastic float is again lowered.
If continuity is present as described, reconnect each of the red wires to the black wires, the safety overflow switch is operating properly. If continuity is not present as described, replace the safety overflow switch.
42311 071310

sound after approximately 5 seconds, as the coil magnet attracts the plunger. 8. Disconnect the dispenser from the power source. 9. Reconnect the pink wire to terminal 5 of the elec- tronic control board.
Location: The solenoid valve is located inside the rear of the dispenser on the right side near the bottom. To test the solenoid valve, access will also be needed to the electronic control board.
If the sound was heard as described and water will not pass through the solenoid valve, there may be a blockage in the water line before or after the solenoid valve or the solenoid valve may require inspection for wear and removal of waterborne particles. If the sound was not heard as described, replace the solenoid valve.

Fill water tank before turning -on thermostat or connecting appliance to power source.
Use only on a properly protected circuit capable of the rated load.
Do not use near combustibles. Follow national/local electrical codes.
READ THE ENTIRE OPERATING MANUAL INCLUDING THE LIMIT OF WARRANTY AND LIABILITY BEFORE BUYING OR USING THIS PRODUCT
Removal and Replacement: 1. Remove all wires from the solenoid valve coil. 2. Turn-off the water supply to the dispenser. 3. Disconnect the water line from the solenoid valve. 4. Remove the two 8-32 slotted-head screws holding the solenoid valve and mounting bracket to the back panel. 5. Lift-out the solenoid valve. 6. Securely install the new solenoid valve to the back panel. 7. Securely fasten the water line to the solenoid valve. 8. Reconnect the wires, FIG. 8.
Test Procedure: 1. Disconnect the dispenser from the power source and turn-off the water supply to the dispenser. 2. Remove the pink wire from terminal 5 of the elec- tronic control board. 3. Check the voltage across the solenoid valve coil terminals with a voltmeter. Connect the dispenser to the power source. The indication must be: a.) 100 to 120 volts ac for 100 to 120 volt models or b.) 200 to 240 volts ac for 200 to 240 volt models or c.) 230 volts ac for 230 volt models after a delay of approximately 5 seconds. 4. Disconnect the dispenser from the power source.

If voltage was present as described, proceed to #5. If voltage was not present as described, refer to the Wir- ing Diagrams and check the dispenser wiring harness.
If continuity is present as described, reconnect the wires and proceed to #7. If continuity is not present as described, replace the solenoid valve coil.
42311 071310

If continuity is present as described, reconnect the wires and proceed to #7. If continuity is not present as described, replace the solenoid valve coil.
Location: The solenoid valve is located behind the large access panel on the left side of the dispenser. To test the solenoid valve, access will also be needed to the electronic control board.

If the sound was heard as described and water will not pass through the solenoid valve, there may be a blockage in the water line before or after the solenoid valve or the solenoid valve may require inspection for wear and removal of waterborne particles. If the sound was not heard as described, replace the solenoid valve.
Removal and Replacement: 1. Remove all wires from the solenoid valve coil. 2. Turn off the water supply to the dispenser. 3. Disconnect the water lines to and from the solenoid valve. 4. Remove the two 8-32 slotted-head screws holding the solenoid valve and mounting bracket to the component bracket. 5. Lift out the solenoid valve. 6. Remove the two 10-32 slotted-head screws holding the solenoid valve to its mounting bracket. 7. Securely install the new solenoid valve to its mount- ing bracket. The direction of flow arrow must be pointing towards the tank lid. 8. Attach the solenoid valve and mounting bracket to the component bracket. 9. Securely fasten the water lines to and from the solenoid valve. 10. Reconnect the wires, FIG. 8.
BUNN 90 psig max operating pressure Strainer/Flow Control # 22300.0750
Test Procedure: 1. Disconnect the dispenser from the power source and turn off the water supply to the dispenser. 2. Remove the pink wire from terminal 5 of the elec- tronic control board. 3. Check the voltage across the solenoid valve coil terminals with a voltmeter. Connect the dispenser to the power source. The indication must be 200 to 240 volts ac for 200 to 240 volt models after a delay of approximately 5 seconds. 4. Disconnect the dispenser from the power source.

RED to Terminal Block RED to Control Board T4
If voltage was present as described, proceed to #5. If voltage was not present as described, refer to the Wir- ing Diagrams and check the dispenser wiring harness.
42311 071310

Tank Heater Location: The tank heater is located in the tank lid.
If the sheath shows no sign of damage, proceed to #5. If the sheath is damaged, replace the tank heater.

If continuity is present as described, reinstall the tank heater. The tank heater is operating properly. If continuity is not present as described, replace the tank heater. Removal and Replacement: 1. Remove the wires to the tank heater. 2. Remove the 8-32 nuts from the tank heater flange. 3. Remove the tank heater. 4. Inspect the tank heater gasket and replace if neces- sary. 5. Securely install the new tank heater. Be certain of a watertight seal. 6. Reconnect the wires, FIG. 10.

BLK to Limit Thermostat BLU to Control Board Relay
Test Procedure: 1. Disconnect the dispenser from the power source. 2. Check the voltage across the terminals of the tank heater with a voltmeter. Connect the dispenser to the power source. The indication must be: a.) 100 to 120 volts ac for 100 to 120 volt models or b.) 200 to 240 volts ac for 200 to 240 volt models or c.) 230 volts ac for 230 volt models. 3. Disconnect the dispenser from the power source.

1800W-120V 07.44 - 08.67 4000W-240V 13.43 - 15.51 4000W-208V 10.09 - 11.99 6000W-240V 08.85 - 10.23 6000W-208V 06.67 - 07.70
If voltage is present as described, proceed to #4. If voltage is not present as described, replace the tank heater.
42311 071310

Removal and Replacement: 1. Disconnect the dispenser from the power source. 2. Disconnect the thermistor from J5 on control board. 3. Loosen the set screw and the two screws securing the two half blocks together. Remove thermistor assembly from overflow tube. 4. Install new thermistor on tube and slide down until it contacts the flared end. NOTE: It’s critical that the thermistor be centered directly under the tube opening. 5. Snug the set screw so the block assembly does not move aroung easily. 6. Connect the thermistor to J5 on control board.
Location: The thermistor is located on the end of the overflow tube above the overflow cup. To test the thermistor, access will also be needed to the electronic control board.

REMOVED, AS AIR MOVEMENT CAN HINDER PROPER READINGS ON THERMISTOR.

Test Procedure: 1. Disconnect the dispenser from the power source. 2. Disconnect the thermistor from J5 on control board. 3. Check the resistance across thermistor with a ohmmeter. The resistance range is approximately 9K @ room temperature to approximately 2K @ 200°F. 4. Disconnect the dispenser from the power source.

If resistance was present as described, the thermistor is working. If resistance was not present as described, replace the control board.
42311 080510

Dispense Valve (PC Only) Location: The Dispense Valve is located behind control panel.
If voltage is not present as described, refer to Wir- ing Diagrams and check the dispenser wiring harness. Also check the control board for proper operation.

Removal and Replacement: 1. Disconnect the dispenser from the power source and allow to cool. 2. Drain enough water from the tank so the water level is below the outlet. 3. Remove the nut and flare nut from the valve. 4. Remove the top cover, shroud, and bracket. 5. Disconnect wires from the valve. 6. Using a back up wrench to hold fitting in place, Remove the valve. 7. Wrap threads of fitting with Teflon tape and install new valve. 8. Install bracket, nut, flare nut, wires and covers.

Test Procedures: 1. Check the valve for coil action. Turn on the valve with the dispense button. Listen carefully in the vicinity of the dispense valve for a click as the coil pulls the plunger in. If no sound is heard as described, proceed to #2. If the sound is heard as described, there may be a blockage in the valve. Disconnect the dispenser from the power source. Remove the valve and inspect for blockage, and de-lime all related areas.
If voltage is present as described, but no coil action is observed, valve is defective. Replace valve and test again to verify repair.
FIG. 18c VALVE REPAIR KIT 18
42311 071310


H5-PC NO JUMPER Early H5E, H5X, H10X Install jumper thru ver. 1.04
120V AC 2 WIRE + GND 120/208V AC 3 WIRE + GND 120/240V AC 3 WIRE + GND SINGLE PHASE
42311 071310 19


H5-PC NO JUMPER Early H5E, H5X, H10X Install jumper thru ver. 1.04
42311 071310 20


H5-PC NO JUMPER Early H5E, H5X, H10X Install jumper thru ver. 1.04
42311 121312 21


H5-PC NO JUMPER Early H5E, H5X, H10X Install jumper thru ver. 1.04
42311 071310 22


H5-PC NO JUMPER Early H5E, H5X, H10X Install jumper thru ver. 1.04
100-120 VOLTS AC or 200-240 VOLTS AC 2 WIRE + GND SINGLE PHASE
42311 071310 23


H5-PC NO JUMPER Early H5E, H5X, H10X Install jumper thru ver. 1.04
230 VOLTS AC 2 WIRE + GND SINGLE PHASE 40712.0000F 05/11 © 2008 BUNN-O-MATIC CORPORATION
42311 050511 24


42311 050511 25
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.