EN
Draper logo
Official user manual

Draper Skylight FlexShade (Skylight 2)

8 pages·1.5 MB·Blind·PDF·ENDEFRITNLJA
Draper Skylight FlexShade (Skylight 2)
Table of Contents 16 sections PLEASE READ - Important Installation Information · PLEASE READ - Safety Information · WARNING · Important Safety Information Important Safety Information · … ShowHide
Page 1 of the Draper Skylight FlexShade (Skylight 2) user manual
Page 1 · click to enlarge
Page 1
Draper Skylight FlexShade (Skylight 2) diagram (page 1)
Fig. 1
Draper Skylight FlexShade (Skylight 2) diagram (page 1)
Fig. 2

Section 4 - Guide Cables and Draw Cable 4

Section 7 - Skylight 2 FlexShade Diagram (Completed) 7

If you have any difficulties installing or servicing your Skylight 2 FlexShade, call your dealer or Draper, Inc.

Draper, Inc. | 411 S. Pearl St. Spiceland, IN 47385

draperinc.com | 765.987.7999 | 800.238.7999 © 2022 All Rights Reserved | FORM: Skylight2FlexShade_Inst22

Page 2 of the Draper Skylight FlexShade (Skylight 2) user manual — PLEASE READ - Cleaning and Maintenance
Page 2 · click to enlarge
Page 2

PLEASE READ - Important Installation Information

1. Inspect all boxes to make sure you have received the proper shades and parts. Controls may be shipped separately, or in same carton as shades.
5. Do not wire motors in parallel without written permission from Draper.
6. All endcaps, fascia, pocket headbox, and other hardware must be installed level. Shades must be level and square.
2. Open cartons lengthwise.
3. Before mounting shades, verify measurements on label provided with shade, and ensure unit is installed at correct width.
7. Read the following installation guidelines thoroughly and follow them carefully. Failure to do so may cause product to fall or otherwise fail, and invalidates warranty.
4. Before connecting switches, controls, or electrical, ensure that power is turned OFF . Wiring indicated in diagram by dashed lines must be completed by an electrician.
8. Installer is responsible for selecting mounting hardware appropriate for site conditions.

PLEASE READ - Safety Information

WARNING

Important Safety Information Important Safety Information

Improper installation and use of the Skylight 2 Flexshade® can result in serious injury or death. Primarily, injuries can occur if the unit falls due to imprecise installa- tion, mishandling of the unit during installation or installation on an insufficient wall or ceiling structure. Please use extreme care.

1. Please read the following installation guidelines thoroughly and follow them carefully. Failure to do so may cause product to fall or otherwise fail, and could result in serious injury.
9. Make sure the limit switches are pointed down or accessible when placing the motor in brackets/endcaps.
10. All motors should be tested and limits set using test cord before shades are wired.
2. Installation and calibration of the unit should only be performed by an authorized, qualified, and experienced professional. In particular, electrical work and wiring [indicated in diagram by dashed lines] must be completed only by a qualified professional electrician who has read this manual completely and is familiar with the construction and operation of this equipment and the hazards involved.
11. Do not wire motors in parallel without written permission from Draper, Inc.
12. During testing or operation, carefully watch the surrounding area for any potential safety concerns including nearby persons or objects.
13. After installation, the entire system, including all sensors, should be carefully tested to ensure safe and normal operation. Extreme care should be taken during testing to remain clear of moving parts to avoid possible injury.
3. Do not affix the unit to wall or ceilings that have inadequate strength to permanently hold the unit during use. It is the owner’s and installer’s responsibility to confirm the wall or ceiling to which the unit attaches is sufficient to permanently hold the weight and stress loads of the unit at all times. Draper, Inc., is not responsible for improper installation, application, testing, or workmanship related to the product at place of installation.
14. Operation of unit should be performed only by authorized and qualified personnel, who have been trained in the safe and effective operation of the unit and understand its safety features.
15. The safety features of the unit , including sensors, should never be disabled, bypassed, or overridden. The system should not be operated until all safety features, including the sensors, are properly and completely installed, calibrated, and tested.
4. It is the installer’s responsibility to make sure appropriate fasteners are used for mounting.
5. All brackets, fascia, headboxes, pockets, wall clips, and other hardware must be installed level. Unit must be level and square.
16. Unit may need to comply with local, state, or district rules and regulations, in particular when installed in schools. All applicable rules and regulations should be reviewed before installation and use.
6. Never leave the area while operating the unit during installation, maintenance, or normal operation, unless it is secure and safe.
7. Before testing or operation, carefully inspect the entire area and path of the shade and areas underneath the shade to be sure no persons or objects are in the area.
17. Failure to precisely follow installation guidelines invalidates all warranties.
18. Custom products/installations may not be reflected in this manual. Call Draper, Inc., if you have questions about the installation of custom products or any questions about your installation.
8. Turn off power and any nearby equipment or cables carrying electricity before connecting switches, wires, controls, or electrical components.

Before Beginning Installation

1. Look for any job site conditions that could interfere with installation or operation of the system.
3. Open cartons lengthwise.
4. Locate and lay out all pieces.
2. Read carefully and be sure to understand all installation instructions and all related operations manuals. These instructions are intended to serve as a guide for the installer and owner. They should be followed closely and combined with the expertise of experienced qualified installers. Draper, Inc., is not responsible for improper installation, application, testing, or workmanship related to the product at place of installation. Please retain all instructions for future use.
5. Inspect all boxes to make sure you have received the proper shade and parts. Controls may be shipped separately, or in same carton as shade.
6. If you have any difficulties with installing, servicing, or operating your shade, call your dealer or Draper, Inc., 765-987-7999.

PLEASE READ - Cleaning and Maintenance

Window covering products manufactured by Draper, when properly installed, should require no operational maintenance or lubrication.

Most of Draper’s standard fabrics may be cleaned at the window by vacuuming with a soft brush attachment. They also may be cleaned by using a sponge or soft cloth and mild solution of warm soapy water. A mild dishwashing liquid is recommended. A clean dry cloth is recommended for the metal finish.

Please NoteExceptions are Flocké and Phifer SW7000 fabrics, which must be cleaned with a dry

art sponge.

Page 3 of the Draper Skylight FlexShade (Skylight 2) user manual — Section 3 - Hem Bar
Page 3 · click to enlarge
Page 3

Section 1 - Endcaps

Please Note: Installer is responsible for selecting mounting hardware appropriate for site conditions.

1. Mark wall, jamb, or ceiling for placement of mounting brackets.
2. Drill small starter holes (if necessary) in mounting surface.
Draper Skylight FlexShade (Skylight 2) — Section 1 - Endcaps diagram (page 3)
Fig. 3 · Section 1 - Endcaps
3. Mount brackets using appropriate fasteners for surface (Figure 1 for bracket dimensions) .
4. Mount fabric/roller assembly. Make sure limit switches are accessible from below the unit (Figure 1) .
5. Install optional bracket covers (if provided) .

Section 2 - Connect Unit to Power

Shade operates on 110-120V, 60 Hz current. Shade is shipped with internal wiring complete and control switch(es) fully boxed, and standardly supplied with 8' (244 cm) cable lead. Wire to connect shade to switch(es) and switch(es) to power supply should be furnished by installer. Connections should be made in accordance with attached wiring diagram, and wiring should comply with national and local electrical codes. DO NOT wire motors in parallel without written permission from Draper. All operating switches should be “off” before power is connected.

Please Note: For low-voltage wiring requirements, Draper recommends consulting with a professional low voltage electrical contractor. It is very important that

shielded and stranded CAT 5 cable be used to prevent any electrical interference. See wiring diagrams on page 7.

Section 3 - Hem Bar

Draper Skylight FlexShade (Skylight 2) — Section 3 - Hem Bar diagram (page 3)
Fig. 4 · Section 3 - Hem Bar
4. Slide hem bar onto fabric panel and retainer.
Page 4 of the Draper Skylight FlexShade (Skylight 2) user manual — Section 4 - Guide Cables and Draw Cable
Page 4 · click to enlarge
Page 4

Section 4 - Guide Cables and Draw Cable

Draper Skylight FlexShade (Skylight 2) — Section 4 - Guide Cables and Draw Cable diagram (page 4)
Fig. 5 · Section 4 - Guide Cables and Draw Cable

Please Note: Make sure that the Hem Bar is close enough to unit to make the following steps as easy as possible, but no closer than 1"-2" (25-51 mm) from the unit.

1. Insert Guide Cable through roller mounting bracket and hem bar endcap (Fig. 3) .
3. Route the Guide Cable over the outside pulley and through the Guide Cable Tensioner (Fig. 4) .
Please NoteThe rope end must be absolutely free of oil and grease. Degrease with
2. Remove the nut and ferrules from the Guide Cable Tensioner.
Draper Skylight FlexShade (Skylight 2) — Section 4 - Guide Cables and Draw Cable diagram (page 4)
Fig. 6 · Section 4 - Guide Cables and Draw Cable
Draper Skylight FlexShade (Skylight 2) — Section 4 - Guide Cables and Draw Cable diagram (page 4)
Fig. 7 · Section 4 - Guide Cables and Draw Cable
4. Pull the Guide Cable tight and install the Tensioner ferrules (Fig. 5) .
5. Tighten the ferrule nut to approximately 13 ft-lb (18 Nm) .
6. Extend the tensioner to tighten the Guide Cable. Do not allow the tensioner to rotate in the bracket.
Draper Skylight FlexShade (Skylight 2) — Section 4 - Guide Cables and Draw Cable diagram (page 4)
Fig. 8 · Section 4 - Guide Cables and Draw Cable
7. Route the draw cable around the two inside pulleys (Fig. 6) .
Draper Skylight FlexShade (Skylight 2) — Section 4 - Guide Cables and Draw Cable diagram (page 4)
Fig. 9 · Section 4 - Guide Cables and Draw Cable
Page 5 of the Draper Skylight FlexShade (Skylight 2) user manual — Left-Hand Cable Spool Right-Hand Cable Spool
Page 5 · click to enlarge
Page 5
8. Wind the Draw Cable 1-2 turns around the Cable Spool at each end of the roller assembly.

Left-Hand Cable Spool Right-Hand Cable Spool

C016.085 Cable Clamp

C016.085 Cable Clamp

9. Insert the Draw Cable through the Cable Spool and Cable Clamp at each end of the assembly (Fig. 7) .

Orientation is CRITICAL.

exiting the spool.

Orientation is CRITICAL.

exiting the spool.

Fabric Panel Fabric Panel

Draw Cable Insertion1-2 wraps around spool Draw Cable Insertion: 1-2 wraps around spool
Draper Skylight FlexShade (Skylight 2) — Left-Hand Cable Spool Right-Hand Cable Spool diagram (page 5)
Fig. 10 · Left-Hand Cable Spool Right-Hand Cable Spool
10. Pull slightly on the Draw Cable to ensure that the Cable Clamp has secured the Draw Cable.
11. Tighten the Draw Cable by pulling it through one of the Cable Clamps.
12. Ensure the Draw Cable is routed properly around the pulleys inside the Hem Bar assembly, as well as around the pulleys in the Mounting Brackets (Fig. 8) .
13. Cut off the excess Draw Cable for each end of the Roller Assembly. Insert the Tensioning Tool into the Spring Cassette Cable Spool and tension the shade 10-20 turns (Fig. 9) .
14. Set the Motor limits so that the shade stops about ½" (13 mm) away from the Mounting Brackets at both ends of shade travel (see "Limit Setting" section) .

may result in damage to the unit. Ensure that the pinch points between the Bracket and Hem Bar are clear during operation.

15. Cycle the unit and make sure the Hem Bar does not contact the Draw Cable during operation. If it does, then more tension is required in the Guide Cable. If required, retract the Tensioner, loosen the Nut, pull more of the Guide Cable through the Tensioner, re-tighten the Nut, and extend the Tensioner. Repeat as needed until the Hem Bar does not contact the Draw Cable.
16. After confirming that the Hem Bar does not contact the Draw Cable and that the installation is complete, shorten the Guide Cables (Fig. 10) .

may need to be replaced if more tension is needed.

Trim excess cable · Trim excess cable

Page 6 of the Draper Skylight FlexShade (Skylight 2) user manual — Section 6 - Dimensions
Page 6 · click to enlarge
Page 6

Section 5 - Limit Setting

Please Note: These instructions are for standard motors. For instructions on setting limits on RTS motors, contact Draper, Inc.

1. Determine which direction of fabric travel corresponds with arrows on motor.
2. Operate shade to desired “Closed” stop position. Adjust the limit by turning the proper socket toward the “+” or “-”.
3. Operate shade to desired “Open” stopping position. Adjust the limit by turning the proper socket toward the “+” or “-”.

Section 6 - Dimensions

Draper Skylight FlexShade (Skylight 2) — Section 6 - Dimensions diagram (page 6)
Fig. 11 · Section 6 - Dimensions

2 "(73mm) Fully Closed 3"(76mm) Hem Bar Width

Fabric Width = Shade Width - 5 "(146mm)

5"(133mm) to fabric panel finished edge (REF)

This Side Faces the Window 5 " (148mm)

This Side Faces the Room

Page 7 of the Draper Skylight FlexShade (Skylight 2) user manual — Section 7 - Skylight 2 FlexShade Diagram (Completed)
Page 7 · click to enlarge
Page 7

Section 7 - Skylight 2 FlexShade Diagram (Completed)

Draper Skylight FlexShade (Skylight 2) — Section 7 - Skylight 2 FlexShade Diagram (Completed) diagram (page 7)
Fig. 12 · Section 7 - Skylight 2 FlexShade Diagram (Completed)
Page 8 of the Draper Skylight FlexShade (Skylight 2) user manual — Controls & System Overview Sonesse RTS ® 120VAC Motors
Page 8 · click to enlarge
Page 8

Section 8 - Wiring Diagrams

Draper Skylight FlexShade (Skylight 2) — Section 8 - Wiring Diagrams diagram (page 8)
Fig. 13 · Section 8 - Wiring Diagrams

Controls & System Overview Sonesse RTS ® 120VAC Motors

Do not wire motors in parallel without written permission from Draper.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Draper Skylight FlexShade (Skylight 2)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Draper Skylight FlexShade (Skylight 2)

Be the first to ask — other owners or our team will answer.

Original document

Draper Skylight FlexShade (Skylight 2) manual PDF

8 pages·1.5 MB·Blind·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…