Installation & Owner's Manual
Original Instructions
Split Type Wall-mounted Air Conditioner
Thank you for choosing our product. Please read this Owner’s Manual carefully before operation and retain it for future reference. If you have lost the Owner's Manual, please contact your local distributor or visit www.greecomcomfort.com/resources for the electronic version.



Indicates a hazardous situation that, if not avoided, will result in death or serious injury.
Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
Indicates a hazardous situation that, if not avoided, may result in minor or moderate injury.
Indicates important but not hazard-related information, used to indicate risk of property damage.
Indicates a hazard that would be assigned a signal word WARNING or CAUTION.
Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons.
1. Damage the product due to improper use or misuse of the product; 2. Altering, changing, servicing or using the product with other equipment without abiding by the instruction manual of manufacturer. 3. Upon verification, the defect of product is directly caused by corrosive gas; 4. Upon verification, the defects are due to transportation damage. 5. Operating, repairing or servicing the unit without following the instruction manual or related regulations. 6. Upon verification, the problem or dispute is caused by the quality specification or performance of parts and components that produced by other manufacturers; 7. Damage caused by natural disasters, corrosive environments or force majeure.
CONFORMITY AND RANGE GENERAL INFORMATION This appliance can be used by children aged from 8 years and above and persons
with reduced physical,sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Please read this owner's manual carefully before operating the unit and retain it for consultation. Instructions for installation and use of this product are provided by the manufacturer.
Only use the air conditioner as instructed in this booklet. These instructions are not intended to cover every possible condition and situation. As with any electrical household appliance, common sense and caution are therefore always recommended for installation, operation and maintenance.


If the supply wire is damaged, it must be replaced by the manufacturer or a licensed HVAC technician or a similarly qualified person in order to avoid a hazard. Be sure to disconnect the power supply before cleaning the air conditioner; to avoid an electrical shock. Wetting of air conditioner may cause the risk of electrical shock. Make sure not to wash your air conditioner under any circumstance.
Volatile liquids such as thinner or gasoline will cause damage to the appearance of air conditioner. (Only use soft dry cloth moist cloth clean the air conditioner cabinet).
Do not dispose this product as unsorted municipal waste. Dispose according to local waste regulations. The temperature of refrigerant circuit is high, please keep the interconnecting wire away from the copper refrigerant lines.


If the supply wire is damaged, it must be replaced by the manufacturer or a licensed HVAC technician or a similarly qualified person in order to avoid a hazard. Be sure to disconnect the power supply before cleaning the air conditioner; to avoid an electrical shock. Wetting of air conditioner may cause the risk of electrical shock. Make sure not to wash your air conditioner under any circumstance. Volatile liquids such as thinner or gasoline will cause damage to the appearance of air conditioner. (Only use soft dry cloth moist cloth clean the air conditioner cabinet). Do not dispose this product as unsorted municipal waste. Dispose according to local waste regulations. The temperature of refrigerant circuit is high, please keep the interconnecting wire away from the copper refrigerant lines.



MULTIU36HP230V1DO MULTIU42HP230V1DO
If the supply wire is damaged, it must be replaced by the manufacturer or a licensed HVAC technician or a similarly qualified person in order to avoid a hazard. Be sure to disconnect the power supply before cleaning the air conditioner; to avoid an electrical shock. Wetting of air conditioner may cause the risk of electrical shock. Make sure not to wash your air conditioner under any circumstance.
Volatile liquids such as thinner or gasoline will cause damage to the appearance of air conditioner. (Only use soft dry cloth moist cloth clean the air conditioner cabinet).
Do not dispose this product as unsorted municipal waste. Dispose according to local waste regulations. The temperature of refrigerant circuit is high, please keep the interconnecting wire away from the copper refrigerant lines.







An all-pole disconnect switch having a contact separation of at least 3mm in all poles should be connected to supply power wiring.
Wrong wire connections may cause malfunction of some electric components. After fixing wire, ensure that leads between connection to fixed point have some space.
The connection pipes and the connection wiring of unit A, unit B, unit C and unit D must correspond to each other respectively.
Provide a circuit breaker with suitable capacity, please note the following table. Circuit breakers will prevent short-circuits and overload. (Caution: do not use a fuse only for circuit protection.
The appliance shall be installed in accordance with national wiring regulations.


An all-pole disconnect switch having a contact separation of at least 3mm in all poles should be connected to supply power wiring.
Wrong wire connections may cause malfunction of some electric components. After fixing wire, ensure that leads between connection to fixed point have some space.
The connection pipes and the connection wiring of unit A, unit B, unit C and unit D must correspond to each other respectively.
Provide a circuit breaker with suitable capacity, please note the following table. Circuit breakers will prevent short-circuits and overload. (Caution: do not use a fuse only for circuit protection.
The appliance shall be installed in accordance with national wiring regulations.


An all-pole disconnect switch having a contact separation of at least 3mm in all poles should be connected to supply power wiring.
Wrong wire connections may cause malfunction of some electric components. After fixing wire, ensure that leads between connection to fixed point have some space.
The connection pipes and the connection wiring oft unit A, unit B, unit C and unit D must be correspond to each other respectively.
Provide a circuit breaker with suitable capacity, please note the following table. Circuit breakers will prevent short-circuits and overload. (Caution: do not use a fuse only for circuit protection.
The appliance shall be installed in accordance with national wiring regulations.


An all-pole disconnect switch having a contact separation of at least 3mm in all poles should be connected to supply power wiring.
Wrong wire connections may cause malfunction of some electric components. After fixing wire, ensure that leads between connection to fixed point have some space.
The connection pipes and the connection wiring of unit A, unit B, unit C and unit D must correspond to each other respectively.
The appliance shall be installed in accordance with national wiring regulations. Provide a circuit breaker with suitable capacity, please note the following table. Circuit breakers will prevent short-circuits and overload. (Caution: do not use a fuse only for circuit protection.


INSTALLER
Use bolts to secure the unit to a flat, solid floor. When mounting the unit on a wall or the roof, make sure the support is firmly secured so that it cannot move in the event of intense vibrations or a strong wind. Do not install the outdoor unit in pits or air vents
Condensation is produced and flows from the out- door unit when the appliance is operating in the heating mode. In order not to disturb neighbours and to respect the environment,install a drain fitting and a drain hose to channel the condensate water. Install the drain fitting and rubber washer on the outdoor unit chassis and connect a drain hose to it as shown in the figure. 82

Use suitable connecting pipes and equipment for the refrigerant R410A.
36Kx3 Max. connection pipe length 164 164 230 164 246 Max. connection pipe length (Simple one indoor unit)
Models(ft) Max. connection pipe length 246 164 246 262 262
Max. connection pipe length (Simple one indoor unit) 1.The refrigerant pipes must not exceed the maximum heights 33ft(18Kx2 & 24Kx2 & 24Kx3) 2.The refrigerant pipes must not exceed the maximum heights 49ft(36x2&36x3&36x4&42x2&42x3&42x4&42x5). Wrap all the refrigerant pipes and joints. Tighten the connections using two wrenches wor-king in opposite directions. BLEEDING
Humid air left inside the refrigerant circuit can cause com- pressor malfunction. After having connected the indoor and outdoor units, bleed the air and humidity from the refrigerant circuit using a vacuum pump.
(1) Unscrew and remove the caps from the 2-way and 3-
way valves. (2) Unscrew and remove the cap from the service valve. (3) Connect the vacuum pump hose to the service valve. (4) Operate the vacuum pump for 10-15 minutes until an
absolute vacuum of 10 mm Hg has been reached. (5) With the vacuum pump still in operation, close the
low-pressure knob on the vacuum pump coupling.
Stop the vacuum pump. (6) Open the 2-way valve by 1/4 turn and then close it
Vacuum pump Vacuum pump
after 10 seconds. Check all the joints for leaks using liquid soap or an electronic leak device.
(7) Turn the body of the 2-way and 3-way valves. Discon- nect the vacuum pump hose. (8) Replace and tighten all the caps on the valves.
3/8'' 26-30 Vacuum pump
1/2'' 33-37 (8) Secure
UNIT Refrigerant fluid direction of fiow
unit need to be installed the indoor unit
(6) Open by 1/4 turn
(7)Turn to open fully
(7)Turn to open fully
Valve cap conversion joint


Do not use mineral oils to clean the unit.
The installation must be done by trained and licensed service personnel adhereing to the instructions provideded in this manual.
Contact a licensed HVAC contractor for installation to avoid any issues that will void the warranty.
Any disconnecting and relocation of a unit must be done by a qualified licensed HVAC technician.
Ensure that the minimum spacing requirements (below) are adhered to.




Problems Due to Improper Installation
Is the installation secure?
The unit may drop, vibrate or make noises
May cause unsatisfactory cooling (heating) problems
Has the gas leakage been checked?
Is the thermal insulation of the unit sufficient?
May cause condensation and water formation
Is the drainage sufficient?
May cause condensation and water formation
Does the power supply voltage match the rated voltage specified on the nameplate?
The unit may break down or the components may burn out
Are the refrigerant lines and wiring correctly installed?
The unit may break down or the components may burn out
Has the unit been safely grounded?
Risk of electrical shock
Do the line sizes comply with requirements?
The unit may break down or the components may burn out
Are there any obstacles near the air inlet and outlet of the indoor and out- door units?
The unit may break down or the components may burn out or not perform to specifications
Is the refrigerant charge correct for the length of refrigerant lines installed
Check to see if more refrigerant needs to be added.
Check Items


Add: West Jinji Rd, Qianshan, Zhuhai,Guangdong, China, 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 E-mail: gree@gree.com.cn www.gree.com
66129932222
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| The unit may drop, vibrate or make noises | Is the installation secure? | p.15 | |
| May cause unsatisfactory cooling (heating) problems | Has the gas leakage been checked? | p.15 | |
| May cause condensation and water formation | Is the thermal insulation of the unit sufficient? | p.15 | |
| May cause condensation and water formation | Is the drainage sufficient? | p.15 | |
| The unit may break down or the components may burn out | Does the power supply voltage match the rated voltage specified on the nameplate? | p.15 | |
| The unit may break down or the components may burn out | Are the refrigerant lines and wiring correctly installed? | p.15 | |
| Risk of electrical shock | Has the unit been safely grounded? | p.15 | |
| The unit may break down or the components may burn out | Do the line sizes comply with requirements? | p.15 | |
| The unit may break down or the components may burn out or not perform to specifications | Are there any obstacles near the air inlet and outlet of the indoor and out- door units? | p.15 | |
| Check to see if more refrigerant needs to be added. | Is the refrigerant charge correct for the length of refrigerant lines installed | p.15 |