EN
Unitech logo
Official user manual

Unitech UHF RFID Reader Module (RM100)

10 pages·293 KB·Scanner·PDF·ENDEFRITNLJA
Unitech UHF RFID Reader Module (RM100)
Table of Contents 9 sections UHF RFID Reader Module · - RM100 - · Quick Start Guide · Features · … ShowHide
Page 1 of the Unitech UHF RFID Reader Module (RM100) user manual — Quick Start Guide
Page 1 · click to enlarge
Page 1
Unitech UHF RFID Reader Module (RM100) — UHF RFID Reader Module diagram (page 1)
Fig. 1 · UHF RFID Reader Module
Unitech UHF RFID Reader Module (RM100) — UHF RFID Reader Module diagram (page 1)
Fig. 2 · UHF RFID Reader Module

UHF RFID Reader Module

- RM100 -

Unitech UHF RFID Reader Module (RM100) — - RM100 - diagram (page 1)
Fig. 3

Quick Start Guide

Version 1.0

Page 2 of the Unitech UHF RFID Reader Module (RM100) user manual — Features
Page 2 · click to enlarge
Page 2

Introducing the RM100 UHF RFID Reader Module Unitech’s RM100 is a high-performance UHF RFID reader module based on the Impinj R2000 chip. It is compliant with EPC C1 Gen2 / ISO 18000-6C.

RM100 has one (Ipex) antenna connector. It also supports dense reader mode (DRM), anti- collision, and Listen-Before-Talk (LBT) features. RM100 has a long operating distance of up to 9 meters when its adjustable TX power is set to 33 dBm with a 4 dBi antenna.

RM100 is small (55 mmx 35 mm x 4.3 mm) and ideal for adding UHF RFID read/write capabilities to a wide range of products and solutions, such as RFID handheld PDA, label printers, and stationary readers.

RM100 uses Serial and USB interfaces to connect to an external processor board or PC host.

Features

Complaint with EPC C1 Gen2 / ISO 18000-6C

Supporting Dense Reader Mode (DRM) and Listen-Before-Talk (LBT) features

One (Ipex) antenna connector

Adjustable transmit output level control from 10 dBm to 33 dBm in 0.1 dB step

Maximum tag read rate of over 750 tags per second

Maximum tag read distance of 27 feet (9 m) with 4 dBi antenna

1 © 2022 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd. All product and company names are trademarks, service marks, or registered trademarks of their respective owners

Page 3 of the Unitech UHF RFID Reader Module (RM100) user manual — Specifications
Page 3 · click to enlarge
Page 3

Specifications

Protocol RFIDEPCglobal Gen 2 (ISO 18000-6C), DRM Architecture RFID ASICIMPINJ R2000 ProcessorATMEL AT91SAM7S-256 Power Voltage5V VDC Interface Connector20-pin (HRS-DF12 SMT connector) UARTBaud rates: 9,600 to 460,800 bps, Logic levels: 3.3 / 5 V USBUSB 2.0 Full Speed (12 Mbps) GPIO2 GPIO pins, Logic levels: 3.3 / 5 V API InterfaceImpinj RF Antenna Connector1 Ipex connector TX powerAdjustable from 10 dBm to 33 dBm @ +/-1.0 dBm accuracy Frequency Stability±20 ppm Harmonic performanceunder 35.0dBc Modulation Depth90% nominal Data EncodingFM0 or Miller code Bit RateSupports uplink data rates of up to 640 Kbps Performance Tag Read RateOver 750 tags/second Inventory ReliabilityThrough anti-collision Tag Read Distance27 feet (9m) with a 4 dBi antenna (36 dBm EIRP) Environmental Compliance Temperature RangeOperating: -20 to +60 degree C, Storage: -30 to + 85 degree C Humidity10% ~ 85% Non-condensing Electrostatic Discharge10 KV to antenna conductor with the antenna attached Physical Dimensions55 mm L X 35 mm W X 4.3 mm H

2 © 2022 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd. All product and company names are trademarks, service marks, or registered trademarks of their respective owners

Page 4 of the Unitech UHF RFID Reader Module (RM100) user manual — Specifications
Page 4 · click to enlarge
Page 4

Package Content Check the package before connecting and operating the RM100. If one or more items in this package are lost, contact your local dealer.

RM100 UHF RFID Reader ModulePower Adaptor Interface boardUSB Cable AntennaRFID Tag
Unitech UHF RFID Reader Module (RM100) — Specifications diagram (page 4)
Fig. 4 · Specifications
Unitech UHF RFID Reader Module (RM100) — Specifications diagram (page 4)
Fig. 5 · Specifications
Unitech UHF RFID Reader Module (RM100) — Specifications diagram (page 4)
Fig. 6 · Specifications
Unitech UHF RFID Reader Module (RM100) — Specifications diagram (page 4)
Fig. 7 · Specifications
Unitech UHF RFID Reader Module (RM100) — Specifications diagram (page 4)
Fig. 8 · Specifications
Unitech UHF RFID Reader Module (RM100) — Specifications diagram (page 4)
Fig. 9 · Specifications
Unitech UHF RFID Reader Module (RM100) — Specifications diagram (page 4)
Fig. 10 · Specifications

3 © 2022 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd. All product and company names are trademarks, service marks, or registered trademarks of their respective owners

Page 5 of the Unitech UHF RFID Reader Module (RM100) user manual — Installing the IndyTool
Page 5 · click to enlarge
Page 5

Tour of the RM100 UHF RFID Reader Module

This section describes the main components and features of the interface board.

Unitech UHF RFID Reader Module (RM100) — Tour of the RM100 UHF RFID Reader Module diagram (page 5)
Fig. 11 · Tour of the RM100 UHF RFID Reader Module

GPIO Port UART Port

Installing the IndyTool

First of all, install the IndyTool before connecting the interface board to a PC. It is possible for multiple versions of IndyTool to co-exist on a single system, so long as a unique install path is used for each, such as the default installation directory.

Installation Procedure 1. Double click the IndyTool installer file, IndyTool v2.6.msi, to launch the installation wizard.

2. When prompted, designate the desired installation directory. The default is: [Program Files]\IMPINJ\IndyTool v2.6
3. Installation includes the C++ runtime libraries and adds a desktop shortcut to the IndyTool application.
4. To Start the IndyTool application:

a. Double click the desktop shortcut, or

b. Use the Start Menu. For example, if installed to the default directory:

Click Start, select All Programs, IMPINJ, Impinj IndyTool v2.6, and click IndyTool.

c. Open the IndyTool installation folder and double click IndyTool.exe.

4 © 2022 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd. All product and company names are trademarks, service marks, or registered trademarks of their respective owners

Power Inlet · Micro USB Port

Page 6 of the Unitech UHF RFID Reader Module (RM100) user manual — Connecting the RM100 to a PC
Page 6 · click to enlarge
Page 6

Connecting the RM100 to a PC

Before operating the Indy tool software for development of the RFID device, follow the steps made below to connect the RM100 to a PC.

1. Install the Indy tool on your PC.
2. Mount the UHF RFID Module onto the interface board.
Unitech UHF RFID Reader Module (RM100) — Connecting the RM100 to a PC diagram (page 6)
Fig. 12 · Connecting the RM100 to a PC
Unitech UHF RFID Reader Module (RM100) — Connecting the RM100 to a PC diagram (page 6)
Fig. 13 · Connecting the RM100 to a PC
3. Connect the interface board to a PC by using a micro USB cable.
Unitech UHF RFID Reader Module (RM100) — Connecting the RM100 to a PC diagram (page 6)
Fig. 14 · Connecting the RM100 to a PC

5 © 2022 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd. All product and company names are trademarks, service marks, or registered trademarks of their respective owners

Page 7 of the Unitech UHF RFID Reader Module (RM100) user manual — Connecting the RM100 to a PC
Page 7 · click to enlarge
Page 7
4. Insert the power connector into the power inlet on the interface board, and then plug the power adapter into an electrical socket.
Unitech UHF RFID Reader Module (RM100) — Connecting the RM100 to a PC diagram (page 7)
Fig. 15 · Connecting the RM100 to a PC
5. Insert the connector of antenna into the antenna port of the RM100 UHF RFID Reader Module.
Unitech UHF RFID Reader Module (RM100) — Connecting the RM100 to a PC diagram (page 7)
Fig. 16 · Connecting the RM100 to a PC

6 © 2022 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd. All product and company names are trademarks, service marks, or registered trademarks of their respective owners

Page 8 of the Unitech UHF RFID Reader Module (RM100) user manual — Connecting the RM100 to a PC
Page 8 · click to enlarge
Page 8
6. Open the IndyTool. Click Start to scan RFID tags by using the RM100 UHF RFID Reader module.
Unitech UHF RFID Reader Module (RM100) — Connecting the RM100 to a PC diagram (page 8)
Fig. 17 · Connecting the RM100 to a PC
Unitech UHF RFID Reader Module (RM100) — Connecting the RM100 to a PC diagram (page 8)
Fig. 18 · Connecting the RM100 to a PC
Unitech UHF RFID Reader Module (RM100) — Connecting the RM100 to a PC diagram (page 8)
Fig. 19 · Connecting the RM100 to a PC

7 © 2022 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd. All product and company names are trademarks, service marks, or registered trademarks of their respective owners

Page 9 of the Unitech UHF RFID Reader Module (RM100) user manual — FCC 警語置於使用者手冊
Page 9 · click to enlarge
Page 9

FCC 警語置於使用者手冊

Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: . Reorient or relocate the receiving antenna. . Increase the separation between the equipment and receiver. . Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. . Consult the dealer or an experienced radio/TV technician for help. FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral devices). End Product Labeling This transmitter module is authorized only for use in devices where the antenna may be installed such that 20 cm may be maintained between the antenna and users. The final end product must be labeled in visible area with the following: “Contains FCC ID: HLERM100U” ” End Product Manual Information The user manual for end users must include the following information in a prominent location “IMPORTANT NOTE: To comply with FCC RF exposure compliance requirements, the antenna used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be colocated or operating in conjunction with any other antenna or transmitter.” This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1) This device may not cause harmful interference and (2) This device must accept any interference received, including interference that may cause undesired operation.

Page 10 of the Unitech UHF RFID Reader Module (RM100) user manual — FCC 警語置於使用者手冊
Page 10 · click to enlarge
Page 10

IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or colocation with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for reevaluating the end product (including the transmitter) and obtaining a separate FCC authorization. This device is intended only for OEM integrators under the following conditions: The antenna must be installed such that 20 cm is maintained between the antenna and users. As long as a condition above is met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end product for any additional compliance requirements required with this module installed (for example, digital device emissions, PC peripheral requirements, etc.).

Ask about the Unitech UHF RFID Reader Module (RM100)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Unitech UHF RFID Reader Module (RM100)

Be the first to ask — other owners or our team will answer.

Original document

Unitech UHF RFID Reader Module (RM100) manual PDF

10 pages·293 KB·Scanner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…