EN
HOFTRONIC logo
Official user manual

HOFTRONIC LED Floodlight Sensor (BK02)

12 pages·219 KB·Light·PDF·ENFRITJA
HOFTRONIC LED Floodlight Sensor (BK02)
Table of Contents 11 sections IP65 · USER MANUAL BEAM LED FLOODLIGHT SENSOR · 5420665 SKU · EN · … ShowHide
Page 1 of the HOFTRONIC LED Floodlight Sensor (BK02) user manual — 5420665 SKU
Page 1 · click to enlarge
Page 1

IP65

HOFTRONIC LED Floodlight Sensor (BK02) — IP65 diagram (page 1)
Fig. 1

USER MANUAL BEAM LED FLOODLIGHT SENSOR

5420665 SKU

5420573 5420580 5420597 · 5420603 5420610 5420627 · 5420634 5420641 5420658

Page 2 of the HOFTRONIC LED Floodlight Sensor (BK02) user manual — SPECIFICATIONS
Page 2 · click to enlarge
Page 2

EN

IMPORTANT SAFETY DETAILS

1. Ensure the AC/Mains power is NOT connected and cannot be unexpectedly reconnected during installation.
2. This product must be installed by a qualified electrician in accordance with instructions provided and in compliance with recognised electrical

and safety regulations relevant to the country it is being installed.

3. This product may NOT be installed by minors or people with a mental disability.
4. Carefully observe all instructions of warnings that are labelled on, or supplied with your product.
5. This product is suitable for outdoor use. If in any doubt, consult a qualified electrician.
6. Please use proper wire for connection. The lenght of output leads should be typically 0.5m-2m in order to keep radio interference minimum.

DIAGRAM

HOFTRONIC LED Floodlight Sensor (BK02) — DIAGRAM diagram (page 2)
Fig. 2

SPECIFICATIONS

VoltageAC 220-240V 50/60Hz Power factor>0.9 Wattage30W50W100W150W200W Lumen3000lm5000lm10000lm15000lm20000lm Chip typeLUMILEDS 2835 CRI>80 MaterialAluminum Die-casting Beam angle90° Product size177x180x54mm223x215x54mm290x272x54mm350x305x54mm404x338x54mm Color temp4000K/6400K Work temp-20°C - +50°C ProtectionIP65 Housing colorBlack
HOFTRONIC LED Floodlight Sensor (BK02) — SPECIFICATIONS diagram (page 2)
Fig. 3
Page 3 of the HOFTRONIC LED Floodlight Sensor (BK02) user manual — 30-50W 100-200W
Page 3 · click to enlarge
Page 3

EN

TESTING PIR

  • Turn the SENS dial clockwise to the maximum point, turn the TIME dial anti-clockwise to the minimum point, turn the LUX dial clockwise to

the Sun.

  • When you switch on the power, the fitting will not illuminate. After a 30 second pre-heat, when the sensor gets the induction signal, the load

will turn on. Once the load switches off , it will then turn on again after 5-15 seconds of the sensor receiving an induction signal.

  • After the sensor goes off, trigger the detection field after 5-10 seconds. The load should work.
  • When there is no induction signals in the sensor, the load should stop working.
  • Turn the LUX dial anti-clockwise to the Moon. If it is adjusted to less than 3 LUX (dark), the load and sensor should not work when testing in

daylight. If you cover the detection window with an opaque object, the load should work.

  • Under no induction signal condition, the load should stop working within 5-15 seconds.

30-50W 100-200W

ADJUSTABLE MOTION SENSOR

The motion sensor on this wide-angle light is fully adjustable for three values, namely: delay time, motion detection speed and ambient light:

  • Delay time: This sets the amount of time it takes for the lamp to switch off after detecting movement. This is adjustable from 10 seconds to 2
  • Detection speed of movement: Of course, you don’t want your wide-angle lamp to switch on with every movement. That is why you can set

the minimum movement speed on the lamp. The speed can be set between 0.6 and 1.5 metres per second.

  • Ambient light: Naturally, you only want the floodlight to switch on when it is dark outside. How dark it should be is up to you with the ambient

light setting. This can be set to a value between 3 and 2000 Lux. At 2000 Lux the floodlight will almost ignore the ambient light. At 3 lux, the

floodlight only switches on when it is really dark outside.

minutes

Page 4 of the HOFTRONIC LED Floodlight Sensor (BK02) user manual — INSTALLATION
Page 4 · click to enlarge
Page 4

INSTALLATION

HOFTRONIC LED Floodlight Sensor (BK02) — INSTALLATION diagram (page 4)
Fig. 4
HOFTRONIC LED Floodlight Sensor (BK02) — INSTALLATION diagram (page 4)
Fig. 5
HOFTRONIC LED Floodlight Sensor (BK02) — INSTALLATION diagram (page 4)
Fig. 6
HOFTRONIC LED Floodlight Sensor (BK02) — INSTALLATION diagram (page 4)
Fig. 7
HOFTRONIC LED Floodlight Sensor (BK02) — INSTALLATION diagram (page 4)
Fig. 8
HOFTRONIC LED Floodlight Sensor (BK02) — INSTALLATION diagram (page 4)
Fig. 9

Install the LED floodlights on the ground, wall or ceiling.

HOFTRONIC LED Floodlight Sensor (BK02) — INSTALLATION diagram (page 4)
Fig. 10

This product should be disposed of responsibly at the end of its life. Please recycle where facilities exist. Check with your local authority or retailer for recycling advise. (Waste Electrical and Electronic Equipment Directive)

Ask about the HOFTRONIC LED Floodlight Sensor (BK02)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the HOFTRONIC LED Floodlight Sensor (BK02)

Be the first to ask — other owners or our team will answer.

Original document

HOFTRONIC LED Floodlight Sensor (BK02) manual PDF

12 pages·219 KB·Light·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…