EN
Ecler logo
Official user manual

Ecler Digital Audio Wall Panel Interface (WP22DN)

19 pages·584 KB·Panel·PDF·ENDEFRITNLJA
Ecler Digital Audio Wall Panel Interface (WP22DN)
Table of Contents 21 sections WP22DN · REMOTE CONTROLS AND INTERFACES DANTE™/AES67 digital audio wall panel interface · USER MANUAL · 50-0366-01 01 WP22DN EN · … ShowHide
Page 1 of the Ecler Digital Audio Wall Panel Interface (WP22DN) user manual — 50-0366-01 01 WP22DN EN
Page 1 · click to enlarge
Page 1
Ecler Digital Audio Wall Panel Interface (WP22DN) — WP22DN diagram (page 1)
Fig. 1

WP22DN

REMOTE CONTROLS AND INTERFACES DANTE™/AES67 digital audio wall panel interface

Ecler Digital Audio Wall Panel Interface (WP22DN) — REMOTE CONTROLS AND INTERFACES DANTE™/AES67 digital audio wall panel interface diagram (page 1)
Fig. 2 · REMOTE CONTROLS AND INTERFACES DANTE™/AES67 digital…
Ecler Digital Audio Wall Panel Interface (WP22DN) — REMOTE CONTROLS AND INTERFACES DANTE™/AES67 digital audio wall panel interface diagram (page 1)
Fig. 3 · REMOTE CONTROLS AND INTERFACES DANTE™/AES67 digital…

USER MANUAL

50-0366-01 01 WP22DN EN

Page 2 of the Ecler Digital Audio Wall Panel Interface (WP22DN) user manual — WP22DN
Page 2 · click to enlarge
Page 2
Page 2 of the Ecler Digital Audio Wall Panel Interface (WP22DN) user manual — WP22DN
Page 3 of the Ecler Digital Audio Wall Panel Interface (WP22DN) user manual — 2. IMPORTANT SAFETY INSTRUCTIONS
Page 3 · click to enlarge
Page 3

1. IMPORTANT REMARK

Ecler Digital Audio Wall Panel Interface (WP22DN) — 1. IMPORTANT REMARK diagram (page 3)
Fig. 4

The lightning flash with arrowhead symbol, within an equilateral triangle, is

intended to alert the user to the presence of uninsulated “dangerous voltage”

within the product’s enclosure that may be of sufficient magnitude to

constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the

user to the presence of important operating and maintenance (servicing)

instructions in the literature accompanying the appliance.

sufficient magnitude to constitute a risk of electric shock. The external wiring connected

to the terminals requires installation by an instructed person or the use of ready-made

leads or cords.

moisture.

socket-outlet with a protective earthing connection.

2. IMPORTANT SAFETY INSTRUCTIONS

1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
Page 4 of the Ecler Digital Audio Wall Panel Interface (WP22DN) user manual — WARNING : This product must not be discarded, under any circumstance, as
Page 4 · click to enlarge
Page 4
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

9. Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10. Protect the power cord from being walked on or pinched particularly at the plugs, convenience receptacles, and at the point where they exit from the apparatus. 11. Only use attachments/accessories specified by the manufacturer. 12. Unplug the apparatus during lightening sorts or when unused for long periods of time. 13. Refer all servicing to qualified personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 14. Disconnecting from mains: Switching off the POWER switch all the functions and light indicators of the amplifier will be stopped, but fully disconnecting the device from mains is done unplugging the power cord from the mains input socket. For this reason, it always shall remain readily operable. 15. Equipment is connected to a socket-outlet with earthing connection by means of a power cord. 16. The marking information is located at the bottom of apparatus. 17. The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on apparatus.

A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to

provide reasonable protection against harmful interference when the equipment is

operated in a commercial environment. This equipment generates, uses, and can radiate

radio frequency energy and, if not installed and used in accordance with the instruction

manual, may cause harmful interference to radio communications. Operation of this

equipment in a residential area is likely to cause harmful interference in which case the

user will be required to correct the interference at his own expense.

WARNING : This product must not be discarded, under any circumstance, as

unsorted urban waste. Take to the nearest electrical and electronic waste

treatment centre.

NEEC AUDIO BARCELONA, S.L. accepts no liability for any damage that may be

caused to people, animal or objects due to failure to comply with the warnings above.

Page 5 of the Ecler Digital Audio Wall Panel Interface (WP22DN) user manual — 4. INTRODUCTION
Page 5 · click to enlarge
Page 5

3. IMPORTANT NOTE

Thank you for choosing our DANTE™/AES67 digital audio wall panel audio interface

WP22DN.

It is VERY IMPORTANT to carefully read this manual and to fully understand its

contents before any connection in order to maximize your use and get the best

performance from this equipment.

To ensure optimal operation of this device, we strongly recommend that its

maintenance be carried out by our authorized Technical Services.

The WP22DN comes with a 3-year warranty.

4. INTRODUCTION

WP22DN is a wall panel interface with DANTE™/AES67 digital audio transport

protocols compatibility.

It features 2 audio MIC/LINE Combo connector inputs in its frontal panel and 2

DANTE™/AES67 conversion channels either directly or by the sum of the analogue

inputs channels (stereo to mono conversion). Also, it features 2 analogue outputs with

duplicated connectors in XLR format for the front panel and Euroblock on the rear

panel, both linked to 2 DANTE™/AES67 channels coming from the local network. It

supports PoE supply or local power supply.

4.1. Main features

  • DANTE™/AES67 compatible audio interface wall panel
  • 2 balanced analog inputs, MIC/LINE level (4 gain taps selector), with Combo
  • Conversion of 2 analog channels to 2 DANTE™/AES67 channels, directly taking

the 2 input channels or combining them (IN1 + IN2 mix)

  • 2 balanced analogue outputs, with XLR connector on the front panel and

Euroblock connector on the rear panel. The outputs come from the conversion of

the 2 DANTE™/AES67 channels received in the unit

  • Ethernet communication interface, RJ45 connector
  • PoE power or by local power supply
  • Phantom Power available for the analogue inputs, 48VDC, 5 mA max.

connector

Page 6 of the Ecler Digital Audio Wall Panel Interface (WP22DN) user manual — 5. INSTALLATION
Page 6 · click to enlarge
Page 6
  • Double gang size, compatible with Ecler double gang surface mount installation

box (WPa2SMBOX, supplied by default with each unit) and with Ecler double

gang flush mount installation box (WPa2FMBOX, optional)

  • Double set of front panel plates: one with access to the inputs’ gain selector, and

the other one without access to the gain selector

5. INSTALLATION

The installation of the WP22DN unit comprises the following steps.

5.1. Mounting the unit

1. Remove the front panel covers, held in place by magnets. You can use the

magnet provided as a tool, by making contact in the upper right corner of the

cover and gently pulling on it.

2. Connect the RJ-45 connector on the CAT5 or higher cable that will connect

the unit to the local area network. If necessary (see below section Installing

an External Power Supply) - connect an external power.

3. If required, connect the analogue audio outputs at the back side of the unit

(equipped with Euroblock terminals) to the desired audio device. These 2

outputs are an exact copy of the 2 outputs available with XLR connectors at

the front panel.

4. Screw the device to the surface mount box or flush mount box.
5. Mount the desired set of front panel covers (with or without access to the

inputs’ gain trimmers), held in place by magnets.

Ecler Digital Audio Wall Panel Interface (WP22DN) — 5. INSTALLATION diagram (page 6)
Fig. 5

WP22DN top view

Page 7 of the Ecler Digital Audio Wall Panel Interface (WP22DN) user manual — 5. INSTALLATION
Page 7 · click to enlarge
Page 7

5.2. WP22DN front panel controls

Ecler Digital Audio Wall Panel Interface (WP22DN) — 5. INSTALLATION diagram (page 7)
Fig. 6

WP22DN front panel view

Behind the right front panel plate (INPUT2 / OUTPUT 2) there’s a 3 x DIP Switch

selector set. It is used to define the contents of DANTE™/AES67 output channels 1 and

2 (coming from straight analogue inputs or a combination of them both) and the

activation of the Phantom Power for the analogue input channels.

Ecler Digital Audio Wall Panel Interface (WP22DN) — 5. INSTALLATION diagram (page 7)
Fig. 7

WP22DN front panel view with front plates removed

Page 8 of the Ecler Digital Audio Wall Panel Interface (WP22DN) user manual — 5. INSTALLATION
Page 8 · click to enlarge
Page 8
DIP Switch 1 (left one)DIP Switch 2 (centre one)DIP Switch 3 (right one) OFF (up position): Dante Channel 1 = analogue IN1OFF (up position): Phantom Power for analogue IN1 and IN2 = OFFOFF (up position): Dante Channel 2 = analogue IN2 ON (down position): Dante Channel 1 = analogue IN1 + IN2ON (down position): Phantom Power for analogue IN1 and IN2 = ONON (down position): Dante Channel 2 = analogue IN2 + IN1

Additionally, each analogue input has its own gain control, with 4 taps: 0 / 10 / 20 /

35dB, as marked in the front panel plates which have that access enabled for the

adjustment using a screwdriver.

proper adjustment of these input gains and resulting levels, once the signals have been

converted to DANTE™/AES67 by the WP22DN unit and received by this

DANTE™/AES67 receiver unit. In the next example a MIMO4040DN unit is receiving

two DANTE™/AES67 channel coming from a WP22DN unit:

Ecler Digital Audio Wall Panel Interface (WP22DN) — 5. INSTALLATION diagram (page 8)
Fig. 8
Page 9 of the Ecler Digital Audio Wall Panel Interface (WP22DN) user manual — 5. INSTALLATION
Page 9 · click to enlarge
Page 9

It’s then possible to monitor their levels in the MIMO4040DN reception unit:

Ecler Digital Audio Wall Panel Interface (WP22DN) — 5. INSTALLATION diagram (page 9)
Fig. 9
Ecler Digital Audio Wall Panel Interface (WP22DN) — 5. INSTALLATION diagram (page 9)
Fig. 10
Page 10 of the Ecler Digital Audio Wall Panel Interface (WP22DN) user manual — 6. POWER UP AND MANAGEMENT FROM DANTE CONTROLLER
Page 10 · click to enlarge
Page 10

5.3. Installing an External Power Supply

In case of not having a PoE type power received in the WP22DN panel directly from the

connection port of the network switch to which it is connected, it is possible to power

the panel through an optional external power supply, model WP-PSU or WP24-PSU,

with stripped wires connected to the Euroblock + and - terminals shown in 5.1.

Mounting the unit.

Ecler Digital Audio Wall Panel Interface (WP22DN) — 6. POWER UP AND MANAGEMENT FROM DANTE CONTROLLER diagram (page 10)
Fig. 11

6. POWER UP AND MANAGEMENT FROM DANTE CONTROLLER

SOFTWARE

6.1 WP22DN Power Up

When the unit is connected to the DANTE™/AES67 network and supplied with PoE or

external DC supply, the front panel LED indicators will show the following information:

POWER LEDwill light up in green meanwhile the unit is powered
DANTE LEDwill light with the following coded information:
  • RED (fixed): during the boot up process
  • AMBER (fixed) : during the PTP (Precision Time Protocol) network time
  • GREEN (fixed): when the unit has been set up as a D DANTE™/AES67 Slave
  • GREEN (blinking): when the unit has been set up as a DANTE™/AES67 Master

WP-PSU power supply · synchronization

Page 11 of the Ecler Digital Audio Wall Panel Interface (WP22DN) user manual — 6. POWER UP AND MANAGEMENT FROM DANTE CONTROLLER
Page 11 · click to enlarge
Page 11

6.2 WP22DN network configuration and DANTE™/AES67 routing

In order to configure WP22DN network parameters and DANTE™/AES67 channels

transmission and reception, Audinate’s application Dante Controller must be used. For

extended information, please refer to the developer's documentation:

www.audinate.com/products/software/dante-controller?lang=es

WP22DN comes from factory with DHCP service activated, meaning this that the unit

will automatically take a dynamic IP address served by a DHCP server in the local area

network where it is connected to, in case it exists. However, specific static network

parameters can be configured using Dante Controller, accessing to the window shown

in this example:

Ecler Digital Audio Wall Panel Interface (WP22DN) — 6. POWER UP AND MANAGEMENT FROM DANTE CONTROLLER diagram (page 11)
Fig. 12
Page 12 of the Ecler Digital Audio Wall Panel Interface (WP22DN) user manual — 6. POWER UP AND MANAGEMENT FROM DANTE CONTROLLER
Page 12 · click to enlarge
Page 12

The unit’s default name (label shown in Dante Controller), from factory, is always

WP22DN–nnnnnn, where “nnnnnn” matches the 6 last digits from the MAC address of

each device. Anyway, this name can be renamed accessing to this window:

Ecler Digital Audio Wall Panel Interface (WP22DN) — 6. POWER UP AND MANAGEMENT FROM DANTE CONTROLLER diagram (page 12)
Fig. 13

The routing for DANTE™/AES67 channel transmitters and receivers can be defined in

the routing window, where all the devices with Dante capabilities detected in the

network will as well appear:

Ecler Digital Audio Wall Panel Interface (WP22DN) — 6. POWER UP AND MANAGEMENT FROM DANTE CONTROLLER diagram (page 12)
Fig. 14
Page 13 of the Ecler Digital Audio Wall Panel Interface (WP22DN) user manual — 4. POWER LED
Page 13 · click to enlarge
Page 13

7. NOTES:

Check that all WP22DN, MIMO4040DN, WPNET, etc. units in a project are working

with the latest firmware versions available.

At www.ecler.com an EclerNet software firmware package is always available,

including the latest official versions of EclerNet Manager firmware and software.

8. FRONT PANEL

Ecler Digital Audio Wall Panel Interface (WP22DN) — 8. FRONT PANEL diagram (page 13)
Fig. 15
1. INPUT 1 and 2 Combo connectors (analogue inputs)
2. INPUT 1 and 2 GAIN selectors (analogue inputs)
3. OUTPUT 1 and 2 XLRM connectors (analogue outputs)

4. POWER LED

5. DANTE LED

Page 14 of the Ecler Digital Audio Wall Panel Interface (WP22DN) user manual — 9. REAR PANEL
Page 14 · click to enlarge
Page 14

9. REAR PANEL

Ecler Digital Audio Wall Panel Interface (WP22DN) — 9. REAR PANEL diagram (page 14)
Fig. 16
1. OUTPUT 1 and 2 Euroblock connectors (analogue outputs)
2. External PSU connector (12 to 24 VDC compatible)
3. RJ45 network DANTE™/AES67 interface
Page 15 of the Ecler Digital Audio Wall Panel Interface (WP22DN) user manual — 10. BLOCK DIAGRAM
Page 15 · click to enlarge
Page 15

10. BLOCK DIAGRAM

Ecler Digital Audio Wall Panel Interface (WP22DN) — 10. BLOCK DIAGRAM diagram (page 15)
Fig. 17
Page 16 of the Ecler Digital Audio Wall Panel Interface (WP22DN) user manual — 11. ASSEMBLY DIAGRAM
Page 16 · click to enlarge
Page 16

11. ASSEMBLY DIAGRAM

Ecler Digital Audio Wall Panel Interface (WP22DN) — 11. ASSEMBLY DIAGRAM diagram (page 16)
Fig. 18
Page 17 of the Ecler Digital Audio Wall Panel Interface (WP22DN) user manual — 12. TECHNICAL FEATURES
Page 17 · click to enlarge
Page 17

12. TECHNICAL FEATURES

WP22DN

Input channels 2 x analog, balanced Connectors 2 x XLRF + jack Combo

Max Input Level +10dBV / +12dBu @ 0dB Gain

Gain settings 0 / 10 / 20 / 35dB

Input Impedance Balanced > 4k

CMRR 20Hz- 20kHz 65dB typ.

THD+Noise @ 1kHz, 0dBV Gain

Phantom power +48VDC, 5mA max. ON / OFF by DIP SWITCH

Output channels 2 analog, balanced, line level Connectors 2 XLR M External, 2 Euroblock Internal

Max Output Level +10dBV / +12dBu @ 0dB Gain

Frequency response (-3dB) 5Hz to 24kHz

Flatness better than ±0.1dB

THD+Noise @ 1kHz

Output Noise floor FFT (20Hz - 20kHz) better than 110dB

Resolution 24bit AKM 48kHz

Dynamic Range ADC 110dB DAC 115dB Latency (fs = 48 kHz) ADC 0,81ms DAC 0 56 Dante™ / AES67 audio interface

Dante™ / AES67 Network Tx / Rx channels 2 / 2

Latency 1 / 2 / 5 ms (selectable)

Connector 1 x RJ45

Cable length between devices 100m CAT5e/CAT6

Poe Power supply PoEclass 0 802.3af Poe PD compliant

External Power supply 12 - 24VDC

Power consumption from PoE 60mA / 2.8W, from Ext power 2.7W

Mounting systems Surface mount installation box WPa2SMBOX

Finished colour White (RAL 9016)

Dimensions 170x85x40mm / 6.7“ x 3.3“ x 1.6“

Weight 0,4 kg. / 0.9 lb.

Show 6 more labels / short text on this page
Analogue inputs · Analogue outputs · AD/DA converters · DC supply · Accessories included · Mechanical
Page 18 of the Ecler Digital Audio Wall Panel Interface (WP22DN) user manual — 13. PACKAGE CONTENTS
Page 18 · click to enlarge
Page 18

13. PACKAGE CONTENTS

  • One WP22DN unit
  • Double frame for mounting on Ecler double electrical boxes
  • Double set of front panel plates: with and without access to analogue inputs’ gain
  • Screws for fixing to surface or flush double electrical boxes
  • Magnet for front plates removal
  • Ecler Double gang surface mount box
  • Euroblock aerial connectors
  • Quick User Guide
  • Warranty Card
Page 19 of the Ecler Digital Audio Wall Panel Interface (WP22DN) user manual — 13. PACKAGE CONTENTS
Page 19 · click to enlarge
Page 19
Ecler Digital Audio Wall Panel Interface (WP22DN) — 13. PACKAGE CONTENTS diagram (page 19)
Fig. 19

All product characteristics are subject to variation due to production tolerances.

NEEC AUDIO BARCELONA S.L. reserves the right to make changes or improvements in the design or

manufacturing that may affect these product specifications.

For technical queries contact your supplier, distributor or complete the contact form on our website,

in Support / Technical requests.

Motors, 166‐168 08038 Barcelona ‐ Spain ‐ (+34) 932238403 | information@ecler.com | www.ecler.com

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Ecler Digital Audio Wall Panel Interface (WP22DN)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Ecler Digital Audio Wall Panel Interface (WP22DN)

Be the first to ask — other owners or our team will answer.

Original document

Ecler Digital Audio Wall Panel Interface (WP22DN) manual PDF

19 pages·584 KB·Panel·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…