Table of Contents 16 sections Assembly Instructions · DESIGNING · HEALTHIER · WORKPLACES · … ShowHide
Page 1 of the Humanscale eFloat One Table user manual — Assembly Instructions
Page 1 · click to enlarge
Page 1
Humanscale eFloat One Table — Assembly Instructions diagram (page 1)
Fig. 1 · Assembly Instructions

Assembly Instructions

North America+1 800 400 0625 Europe: +353 (0)1 858 0910 Asia Pacific: +8522581 0570
Page 2 of the Humanscale eFloat One Table user manual — DESIGNING
Page 2 · click to enlarge
Page 2

DESIGNING

HEALTHIER

WORKPLACES

Page 3 of the Humanscale eFloat One Table user manual — DESIGNING
Page 3 · click to enlarge
Page 3
Page 3 of the Humanscale eFloat One Table user manual — DESIGNING
Page 4 of the Humanscale eFloat One Table user manual — USE CARE WHEN OPERATING DESK :
Page 4 · click to enlarge
Page 4

Important Safety Instructions

WHEN USING AN ELECTRICAL FURNISHING, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED. READ ALL INSTRUCTIONS BEFORE USING (THIS FURNISHING). HUMANSCALE CANNOT BE HELD LIABLE FOR INJURY OR DAMAGE CAUSED BY NON-COMPLIANCE WITH THESE INSTRUCTIONS. SAVE THESE INSTRUCTIONS AND PASS THEM ON TO ANY FUTURE USER.

  • Close supervision is necessary when this furnishing is used by, or near children, invalids, or disabled persons .
  • Use this furnishing only for its intended use as described in these instructions. Do not use attachments not recommended by the manufacturer.
  • Never operate this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Return the furnishing to a service center for examination and repair.
  • Keep the cord away from heated surfaces.
  • Never operate the furnishing with the air openings blocked. Keep the air openings free of lint, hair, and the like.
  • Never drop or insert any object into any opening.
  • Do not use outdoors.
  • Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
  • To disconnect, turn all controls to the off position, then remove plug from outlet.

DO NOT OVERLOAD DESK: To prevent the table from tipping or collapsing, make sure the desk is not overloaded by the weight of the worksurface and items on table. Evenly distribute load; excess loads near edges can reduce stability and lead to tip over.

  • Worksurfaces must be at least 3/4” (20mm) thick . Work surfaces must not weigh more than

5lbs square/ft. For stability, maximum worksurface size is 36” x 28”.

  • Do not exceed maximum load of 90lbs (40.9kg) (110lbs (49.9kg) excluding worksurface)
  • For loading always put heavier items in the center and distribute the load.
  • Do not sit or stand on table.

USE CARE WHEN OPERATING DESK :

  • Before using the table check for any visible signs of damage . Do not use a damaged product.
Page 5 of the Humanscale eFloat One Table user manual — Important Safety Instructions
Page 5 · click to enlarge
Page 5
  • Make sure no obstacles are in the desk’s path and that the desk is not touching walls or neighboring objects .
  • Items taller than 20” in height should not be placed or stored under the desk .
  • Keep Table Frame dry. Keep all electrical components away from water and high humidity. Do not spray cleaning solutions directly onto table frame.
  • Working Temperature for table is 5 - 40 O C
  • Make sure all the cords are the appropriate length to accommodate the change in height .
  • In order to avoid any pinching, please ensure that hand or other body parts are in a safe position during the operation.
  • Unplug power cord during a thunderstorm or if you do not intend to use the desk for a long time .
  • Never use the table if it has a damaged cords or plugs.
  • Keep cords away from heated surfaces.

DO NOT OPEN ELECTRICAL COMPONENTS: Do not attempt to service the tables components. There are no user-serviceable components within the motor control box, hand switch, or table legs. If your table needs service or you are having issues with your table, please contact customer service.

Page 6 of the Humanscale eFloat One Table user manual — Parts Included
Page 6 · click to enlarge
Page 6

Before Getting Started

  • If using a power drill, use a low torque setting .
  • Do assemble product on a protective surface.
  • 2 or more people maybe required to maneuver the table.
  • After assembly the table will need to have initial set up/reset performed before table can be

used.

Philips Head Screw Driver

Power Drill with Philips driver bit (optional)

Parts Included

(2) Power Supply Straps

1x 4mm Allen Key

Show 10 more labels / short text on this page
Tools Required · X Base · Leg Column · (2) Wing Brackets · 2836 Worksurface · Base Plate · Hand Switch · Power Supply · (5) Cable Ties · Power Cord
Page 7 of the Humanscale eFloat One Table user manual — Before Getting Started
Page 7 · click to enlarge
Page 7
Humanscale eFloat One Table — Before Getting Started diagram (page 7)
Fig. 2 · Before Getting Started

(6) ST5 X 20 Wood Screws (4) M6 X 10 Machine Screws

(4) M6 X 40 Machine Screws (4) M6 X 14 Machine Screws

(2) ST5 X 18 Wood Screws (4) ST3.5 X 16 Wood Screws

Page 8 of the Humanscale eFloat One Table user manual — Assembly Instructions
Page 8 · click to enlarge
Page 8

Assembly Instructions

Attach the Wing Brackets to Leg Column using the (4) M4 X 10 screws and 4mm Allen Key.

Humanscale eFloat One Table — Assembly Instructions diagram (page 8)
Fig. 3 · Assembly Instructions

Secure the Leg to the worksurface using the (6) ST5 X 20mm screws, ensuring that the cords are

Secure the feet to the Leg. Using both the (4) M6 X 14 and (4) M6 X 40 Screws with the 4mm

Humanscale eFloat One Table — Assembly Instructions diagram (page 8)
Fig. 4 · Assembly Instructions

Allen key

Page 9 of the Humanscale eFloat One Table user manual — UNDER HAND SWITCH
Page 9 · click to enlarge
Page 9

Secure the hand switch to the worksurface in your desired location using the (2) ST5 X 18, screw

along the front edge of worksurface. Pilot holes are positioned on the left/right hand side of the

worksurface in our recommended location(s).

Humanscale eFloat One Table — UNDER HAND SWITCH diagram (page 9)
Fig. 5

Secure the Power Supply to the worksurface in your desired location using the provided Cable

Straps. To secure the Cable Straps, peel and stick to desired location and secure with the (4) ST3.5

Plug the Leg Column into the hand switch. Connect the power supply to the hand switch. Plug the

power cord into the power supply. Use the provided Cable ties to secure cables to underside of

worksurface (not pictured), with either double sided tape or the (5) ST5 X 16 Screws.

Humanscale eFloat One Table — UNDER HAND SWITCH diagram (page 9)
Fig. 6

Flip your Table right side up and plug into outlet. Reset the desk per instructions in following

section.

YOU MUST RESET THE DESK BEFORE USE. FOLLOW INSTRUCTIONS ON INITIAL SETUP/RESET

UNDER HAND SWITCH

Page 10 of the Humanscale eFloat One Table user manual — LED indicator:
Page 10 · click to enlarge
Page 10

Hand Switch

Humanscale eFloat One Table — Hand Switch diagram (page 10)
Fig. 7 · Hand Switch

UP DOWN

Initial Setup / Reset

1. Press the DOWN button, moving the desk to its lowest position, then release.
2. Hold the DOWN button while the desk clicks lower, slightly rises and stops.

Your desk is now ready to use. The desk base can be adjusted by pressing and holding either the UP/

DOWN button until the desired height is reached.

LED indicator:

Blue - Reset status

Red - Abnormal state

Page 11 of the Humanscale eFloat One Table user manual — Technical Data
Page 11 · click to enlarge
Page 11

Trouble Shooting

ErrorSolution Table does not moveEnsure all cords are fully secured and the outlet your table is plugged into has power. Table moves at a slow rateReset table. Hand Switch LED RedEnsure all cables are fully secured. Follow the steps to Reset your table. If you are still encountering an error please call customer care.

Technical Data

Power supply100-240VAC 50/60Hz Maximum input current1.5A Stand by power consumption, primarily<0.3W Operating Temperature0 - 40C Height Range23.4” - 49” Travel Speed1” per second (no load) Noise Level< 50dB Maximum lift capacity90lbs (40.9kg) / 110lbs (49.9kg) excluding worksurface Duty Cycle10% Max. 2 min on, 18 mins off
Page 12 of the Humanscale eFloat One Table user manual — GT-NPD-AI-8896-001-R01
Page 12 · click to enlarge
Page 12

1114 6th Ave, 15th Floor New York, NY 10036

GT-NPD-AI-8896-001-R01

humanscale.com

For our terms and conditions please go to https://www.humanscale.com/about/legal-information/terms-conditions.cfm

© 2021 Humanscale Corporation. The text and artwork are copyrighted materials. All rights reserved. The Humanscale mark and logo are trademarks of Humanscale Corporation and are registered in the United States and certain other countries.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Humanscale eFloat One Table

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Humanscale eFloat One Table

Be the first to ask — other owners or our team will answer.

Original document

Humanscale eFloat One Table manual PDF

12 pages·873 KB·Desk·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…