EN
Official user manual

Phytech New Generation 300 Sensor

9 pages·172 KB·Sensor·PDF·ENDEFRITNLJA
Phytech New Generation 300 Sensor
Table of Contents 4 sections New Generation 300 sensor · User Manual · Version 1.01 · WARNING: ShowHide
Page 1 of the Phytech New Generation 300 Sensor user manual — Version 1.01
Page 1 · click to enlarge
Page 1
Phytech New Generation 300 Sensor — New Generation 300 sensor diagram (page 1)
Fig. 1 · New Generation 300 sensor

New Generation 300 sensor

User Manual

Version 1.01

Page 2 of the Phytech New Generation 300 Sensor user manual — New Generation 300 sensor
Page 2 · click to enlarge
Page 2
1. General description

The Phytech 300 plant sensor is part of an advanced AG IoT platform for optimized Irrigation management. It is an upgraded version of the previous, 102 plant sensor and performs as part of Phytech’s New Generation. The Phytech plant sensor (300 sensor) measures and transmits data to the hub. The hub organizes the data and then sends it to a Phytech datalogger. Finally, the data is sent to the Phytech cloud for analysis and processing. The outcome is a simple color scheme that aids the grower to decide online when and how much to irrigate.

2. Installation and operation

2.1 Hub Installation 2.1.1 Up to 20 hubs can connect to a single logger. 2.1.2 The maximum distance between the hub and the logger is 300 meters. 2.1.3 After the logger is set up, set the hub near the middle tree of the project in between the trees in the row. 2.1.4 Mound the hub on a tree or in soil (Figure B). 2.1.5 Turn the hub switch ON to activate.

Page 3 of the Phytech New Generation 300 Sensor user manual — New Generation 300 sensor
Page 3 · click to enlarge
Page 3
Phytech New Generation 300 Sensor — New Generation 300 sensor diagram (page 3)
Fig. 2 · New Generation 300 sensor

2.2 Sensor installation Up to 40 type 300 sensors can connect to a single Hub. The maximum distance between the sensors and the Hub is 80 m.Sensor must be installed after the hub was successfully installed and while in sensor acquiring mode. The 300 sensor is a versatile sensor that can be installed as a dendrometer or a fruit sensor. For a dendrometer - a “triangle” and attaching screw (with butterfly screw) need to be attached to the sensor. For a fruit sensor - plastic “hooks” or “claws” need to be attached to the sensor.

Page 4 of the Phytech New Generation 300 Sensor user manual — New Generation 300 sensor
Page 4 · click to enlarge
Page 4

2.2.1 Dendrometer (Figure C1) 2.3.1.1 Choose a smooth area above of the grafting on the scion of

the tree, preferably before any branching of the trunk. If there is

no space before branching, choose the main tree branch. The

chosen area should preferably have a clear line of sight to the

Hub.

2.3.1.2 On some tree species scraping off the bark is needed with a

knife - a flat surface is ideal.

2.3.1.3 Use a drill to drill a 2 mm x 20 mm deep hole at a 90

degree angle into the tree trunk.

2.3.1.4 Screw the attaching screw through the dendrometer

designated hole. Note that the butterfly screw is completely free.

2.3.1.5 Screw the attaching screw to the new hole in the tree until

the thread is completely embedded and the screw feels secure.

2.3.1.6 Push the calibration spacer device to set the right distance

between the dendrometer piston tip and the tree trunk. Once the

for a Hub.

2.3.1.7 Wait for the blinking to stop and the LED to become

steady, an indication that the sensor has connected to the Hub.

2.3.1.8 Tighten the butterfly screw into place.

2.3.1.9 Push the calibration device back and take your hands off

the sensor.

Page 5 of the Phytech New Generation 300 Sensor user manual — New Generation 300 sensor
Page 5 · click to enlarge
Page 5

2.3.1.10 In case the light turns off while in the blinking stage

(meaning the sensor could not connect to the Hub) open the

tree and redo steps ‘6’ to ‘10’.

butterfly screw to completely release the dendrometer from the

2.3.1.11 If the dendrometer still doesn’t connect - replace the

dendrometer.

2.3.1.12 Repeat for all dendrometers in the project.

piston isn’t closed at all should send “I am dead message”.

2.3.1.13 Sensors that their butterfly screw open, meaning the

2.2.2 Dendrometer recalibration 2.3.2.1 Release the butterfly screw and distance the dendrometer

from the tree until the piston is free.

2.3.2.2 Push the dendrometer calibration spacer towards the tree

until the spacer reaches the trunk.

2.3.2.3 Tighten the screw into place.

2.3.2.3 Take your hands off the sensor.

2.2.3 Fruit sensor (Figure C2)

2.3.3.1 Select 3 fruits on the chosen tree that look healthy at a

regular size and are reachable by hand.

Page 6 of the Phytech New Generation 300 Sensor user manual — New Generation 300 sensor
Page 6 · click to enlarge
Page 6

2.3.3.1.1 The selected fruits should be representative of all fruits

on the tree/plot.

2.3.3.1.2 Try to avoid choosing fruits that are exposed to the sun

2.3.3.2 For installing the sensor, open the sensor's “hooks” or

or located in a very high/low position.

“claws” and place them on the desired fruit.

2.3.3.2 The LED on the sensor will immediately start blinking

when opening the fruit sensor.

2.3.3.2 Make sure the sensor LED becomes stable, meaning the

installation is successful.

2.3.3.2 After installing, shake the branches gently and make sure

the sensor is staying in its place.

2.3.3.2 Come and visit the fruit installation 1-2 weeks after

installing to make sure the fruits you chose are indeed

representative to the plot (replace them if needed).

2.3.3.2 Sensors that fall on soil should send “I am dead message”.

Phytech New Generation 300 Sensor — New Generation 300 sensor diagram (page 6)
Fig. 3 · New Generation 300 sensor
Page 7 of the Phytech New Generation 300 Sensor user manual — D
Page 7 · click to enlarge
Page 7
3. Received data

The data received from the sensors reaches the server where it is analyzed. The analyzed data provides users plant status and irrigation recommendations via web and mobile apps (Figure D).

Phytech New Generation 300 Sensor — New Generation 300 sensor diagram (page 7)
Fig. 4 · New Generation 300 sensor

D

Page 8 of the Phytech New Generation 300 Sensor user manual — New Generation 300 sensor
Page 8 · click to enlarge
Page 8
  • 4. Product features 4.2 Hub
  • 40 sensors per hub.
  • Easy installation. 4.3 300 Sensor
  • Easy mount.
  • High resolution trunk/fruit measurements.
  • Event triggered radio transmission. 5. Interfaces 5.2 Hub
  • ON/OFF switch.
  • 1 indication LED. 5.3 300 Sensor
  • Indication LED.
  • 6. Radio
  • UHF 433.9 MHz.
  • FM modulation.
  • 2.4 kbps.
  • Custom antenna

Operation is subject to the following two conditions:

(1) This device may not cause harmful interference.

(2) This device must accept any interference received, including interference that may cause undesired operation.

This device complies with FCC Rules Part 15 and with Industry Canada licence- exempt RSS standard(s). Operation is subject to two conditions: (1) This device may not cause harmful

Page 9 of the Phytech New Generation 300 Sensor user manual — WARNING:
Page 9 · click to enlarge
Page 9

interference, and (2) this device must accept any interference that may be received or that may cause undesired operation.

Changes or modifications to this equipment not expressly approved by the party responsible for compliance (Phytech Ltd.) could void the user’s authority to operate the equipment.

Professional installation is required due to the intended application of the system is exclusively for the commercial/industry use.

WARNING:

It is the responsibility of the installer to ensure that when using the outdoor antenna kits in the United States (or where FCC rules apply), only those antennas certified with the product are used. The use of any antenna other than those certified with the product is expressly forbidden in accordance with FCC rules CFR47 part 15.204."

7. Electrical 7.1 Hub
  • input voltage: 2.7-3.2 Volts (2X type C alkaline battery). 7.2 300 Sensor
  • input voltage: 2.7-3.2 Volts (2X AAA alkaline battery).

Ask about the Phytech New Generation 300 Sensor

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Phytech New Generation 300 Sensor

Be the first to ask — other owners or our team will answer.

Original document

Phytech New Generation 300 Sensor manual PDF

9 pages·172 KB·Sensor·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…