EN
Hisense logo
Official user manual

Hisense Electric Range (HER30F5CSS)

28 pages·1.9 MB·Range·PDF·ENDEFRITNLJA
Hisense Electric Range (HER30F5CSS)
Table of Contents 26 sections Front page · ae · Before you begin · For your safety · … ShowHide
Page 1 of the Hisense Electric Range (HER30F5CSS) user manual — ELECTRIC RANGE
Page 1 · click to enlarge
Page 1
Hisense Electric Range (HER30F5CSS) — Front page diagram (page 1)
Fig. 1 · Front page
Hisense Electric Range (HER30F5CSS) — Front page diagram (page 1)
Fig. 2 · Front page
Hisense Electric Range (HER30F5CSS) — Front page diagram (page 1)
Fig. 3 · Front page
Hisense Electric Range (HER30F5CSS) — Front page diagram (page 1)
Fig. 4 · Front page

INSTRUCTIONS FOR INSTALLATION

Hisense Electric Range (HER30F5CSS) — INSTRUCTIONS FOR INSTALLATION diagram (page 1)
Fig. 5

ELECTRIC RANGE

Hisense Electric Range (HER30F5CSS) — ELECTRIC RANGE diagram (page 1)
Fig. 6
Hisense Electric Range (HER30F5CSS) — ELECTRIC RANGE diagram (page 1)
Fig. 7
Page 2 of the Hisense Electric Range (HER30F5CSS) user manual — Contents
Page 2 · click to enlarge
Page 2

Contents

3 Before you begin

4 For your safety

4 Tip-Over hazard

4 Anti-Tip Bracket

4 Tools and materials

5 Steps for installation

5 Remove packaging materials

5 Prepare the opening

7 Electrical installation

11 Anti-tip device installation

12 Level the range

12 Final installation check list

Page 3 of the Hisense Electric Range (HER30F5CSS) user manual — Before you begin
Page 3 · click to enlarge
Page 3

Before you begin

Read these instructions completely and carefully.

Propper installation is the responsibillity of the installer.

Page 4 of the Hisense Electric Range (HER30F5CSS) user manual — Tools and materials Tools you may need
Page 4 · click to enlarge
Page 4

For your safety

Tip-Over hazard

Hisense Electric Range (HER30F5CSS) — For your safety diagram (page 4)
Fig. 8 · For your safety

A. A child or adult can tip the range and be killed. B. Verify the anti-tip device has been properly installed and engaged (See below). C. Ensure the anti-tip device is re-engaged when the range is

moved (See below). D. Do not operate the range without the anti-tip device in place

Anti-Tip Bracket

Hisense Electric Range (HER30F5CSS) — Anti-Tip Bracket diagram (page 4)
Fig. 9 · Anti-Tip Bracket
  • To reduce the risk of tipping the range, the range must be secured by a properly installed anti-tip bracket.
  • See installation instructions shipped with the bracket for complete details before attempting to install.

Tools and materials Tools you may need

Hisense Electric Range (HER30F5CSS) — Tools and materials Tools you may need diagram (page 4)
Fig. 10 · Tools and materials Tools you may need
Flat-blade and Phillips screwdriverDrill, awl or nailOpen-end wrenchPipe wrench (2)LevelPencil and rulerUtility knife

Materials you may need

Power Cord Clamp Squeeze Connector 4' long with strain relief (For Conduit Installations Only).

UL Listed 40 AMP 4-Wire or 3-Wire Cord

Page 5 of the Hisense Electric Range (HER30F5CSS) user manual — Prepare the opening (for indoor use only)
Page 5 · click to enlarge
Page 5

Steps for installation

Remove packaging materials Failure to remove packaging materials could result in damage to the appliance. Remove all packing parts from the oven, racks, heating elements and drawer. Also remove protective film and labels on the door, cooktop and control panel.

Prepare the opening (for indoor use only)

See ilustrations for all rough-in and spacing dimensions. The appliance may be placed with 0'' clearance (flush) at the back walls and side walls of the cabinets.

Hisense Electric Range (HER30F5CSS) — Prepare the opening (for indoor use only) diagram (page 5)
Fig. 11 · Prepare the opening (for indoor use only)

A. Recommended acceptable electrical outlet area. Orient the electrical receptacle so the length is parallel to the floor.

Hisense Electric Range (HER30F5CSS) — Prepare the opening (for indoor use only) diagram (page 5)
Fig. 12 · Prepare the opening (for indoor use only)
Page 6 of the Hisense Electric Range (HER30F5CSS) user manual — Rating plate
Page 6 · click to enlarge
Page 6

Minimum dimensions between cooktop, walls and above the cooktop

  • Provide adequate clearances between the range and adjacent combustible surfaces. These dimensions must be met for the safe use of your appliance.
  • Make sure the wall covering, countertop, flooring and cabinets around the range can withstand the heat (up to 200°F (90°C)) generated by the range.
  • Allow 30'’ minimum clearance between surface units and bottom of an unprotected wood or metal cabinet, or allow a 24'’ minimum when the bottom of wood or metal cabinets is protected by no less than 1/4'’ thick flame retardant millboard covered with not less than No 28MSG sheet metal, (0,015'’) thick stainless steel, 0,024'’ aluminium or 0,020'’ copper.
  • This appliance has been approved for 0'’ spacing to adjacent surfaces above the cooktop. However, a 6'’ minimum spacing to surfaces less than 15'’ above the cooktop and adjacent cabinet is recomended to reduce steam, grease platter, and heat exposure.
  • Install with zero clearance on sides and back.
Hisense Electric Range (HER30F5CSS) — Minimum dimensions between cooktop, walls and above the cooktop diagram (page 6)
Fig. 13 · Minimum dimensions between cooktop, walls and above…

Cabinet storage space above the cooktop should be avoided to reduce the risk of burns or fire when reaching over hot surface elements. If cabinet storage space is to be provided above the cooktop, the risk can be reduced by installing an appliance hood that projects at least 5'’ beyond the front of the cabinets. Cabinets installed above the cooktop must be no deeper than 16'’.

Hisense Electric Range (HER30F5CSS) — Minimum dimensions between cooktop, walls and above the cooktop diagram (page 6)
Fig. 14 · Minimum dimensions between cooktop, walls and above…

Rating plate

The rating plate indicating the basic information about the appliance is located on the oven frame and it is visible when the oven door is opened.

Page 7 of the Hisense Electric Range (HER30F5CSS) user manual — For conduit installation
Page 7 · click to enlarge
Page 7

Electrical installation

Hisense Electric Range (HER30F5CSS) — Electrical installation diagram (page 7)
Fig. 15 · Electrical installation

Power cord and conduit installation

On the back side of the appliance remove the metal cover by removing screws using a screwdriver. Do not discard these screws.

INFORMATION! NOTE! Power cord and conduit with strain relief are not included in the appliance. It must be purchased separately.

Hisense Electric Range (HER30F5CSS) — Electrical installation diagram (page 7)
Fig. 16 · Electrical installation
Range rating, wattsSpecified rating of power-supply-cord kit, amperesDiameter (inches) of the range connection opening 120/240 volts 120/ 3-wire 3-wir208 volts e40 or 50 APower cordConduit 11900 - 14200 8900- 108001 3/8''1 1/8''

For power cord installation Assemble the strain relief in the connection plate hole (1 3/8''). Insert the power cord through the strain relief and tighten the clamp screws.

Hisense Electric Range (HER30F5CSS) — Electrical installation diagram (page 7)
Fig. 17 · Electrical installation
1. Conduit connection plate 2. Power cord 3. Strain relief

For conduit installation

Remove the conduit connection plate by removing two screws and rotating it, as shown below. The conduit hole (1 1/8'') must be used. Tighten both screws back.

Page 8 of the Hisense Electric Range (HER30F5CSS) user manual — Three-Wire Cord Connection
Page 8 · click to enlarge
Page 8
Hisense Electric Range (HER30F5CSS) — Three-Wire Cord Connection diagram (page 8)
Fig. 18 · Three-Wire Cord Connection

Prepare the conduit cord (insulation stripped) as shown in A.

Install the conduit cord into the connection plate as shown in B.

Insert the strain relief into the conduit hole (1 ¹⁄8''). Then thread the conduit cord through the body (2) of the strain relief and fasten the ring (1). Reinstall the connection plate into possition and screw up.

Three-Wire Cord Connection

Hisense Electric Range (HER30F5CSS) — Three-Wire Cord Connection diagram (page 8)
Fig. 19 · Three-Wire Cord Connection

The neutral wire of the power cord must be connected to the neutral terminal located in the center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block.

Hisense Electric Range (HER30F5CSS) — Three-Wire Cord Connection diagram (page 8)
Fig. 20 · Three-Wire Cord Connection
1. Live 1 2. Ground strap 3. Neutral terminal 4. Live 2 5. Ground plate

A. Black B. White C. Red

  • Remove the 3 screws lower the terminal on the terminal block. Do not loosen the upper screws.
  • Install the three-wire cord kit and strain relief in the hole in the connection plate.
  • Connect the center (white/neutral) wire lead to the center terminal.
  • Connect the red and black leads to the outside terminals.
  • Push the cord upward (to relieve strain), while tightening the strain relief clamp.
  • Securely tighten each screw (35 to 50 in-lbs).
Page 9 of the Hisense Electric Range (HER30F5CSS) user manual — Four-Wire Cord Connection
Page 9 · click to enlarge
Page 9

Three-Wire Conduit Connection

1. Line 1 2. Ground Strap 3. Neutral terminal 4. Live 2 5. Ground plate 6. Wire tips
Hisense Electric Range (HER30F5CSS) — Three-Wire Conduit Connection diagram (page 9)
Fig. 21 · Three-Wire Conduit Connection

A. Black B. White C. Red

  • Loosen the 3 lower terminal screws on the terminal block. Strip wire to expose tip about 3/8'' long.
  • Insert the center (white/neutral) wire tip through the bottom center terminal block opening. On certain models, the wire will need to be inserted through the ground strap opening and then into the bottom center block opening. Insert the two side bare wire tips into the lower left and the lower right terminal block openings.
  • Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.) Do not over-tighten the screws.

Four-Wire Cord Connection

Hisense Electric Range (HER30F5CSS) — Four-Wire Cord Connection diagram (page 9)
Fig. 22 · Four-Wire Cord Connection

The neutral wire of the supply circuit must be connected to the neutral terminal located in the lower center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block. The grounding lead must be connected to the frame of the range with the ground plate and ground screw.

Hisense Electric Range (HER30F5CSS) — Four-Wire Cord Connection diagram (page 9)
Fig. 23 · Four-Wire Cord Connection
1. Live 1 2. Ground strap 3. Neutral terminal 4. Live 2 5. Ground plate 6. Ground screw

A. Black B. White C. Red D. Green

  • Remove the 3 lower screws from the terminal block. Do not loosen the upper screws.
  • Remove the ground screw and ground plate and retain them.
  • Cut the ground strap below the terminal block and discard the lower section.
  • Insert the ground screw through the power cord ground wire ring through the ground plate and back into the range frame. Tighten securely, but do not over-tighten (15 to 20 in-lbs).
Page 10 of the Hisense Electric Range (HER30F5CSS) user manual — Four-Wire Conduit Connection
Page 10 · click to enlarge
Page 10
  • Insert the 3 terminal screws through each power cord terminal ring and back into the terminal block. Be certain the white wire is in the center.
  • Securely tighten each screw (35 to 50 in-lbs).

Four-Wire Conduit Connection

1. Live 1 2. Ground strap 3. Neutral terminal 4. Live 2 5. Ground plate 6. Ground screw 7. Wire tips
Hisense Electric Range (HER30F5CSS) — Four-Wire Conduit Connection diagram (page 10)
Fig. 24 · Four-Wire Conduit Connection

A. Black B. White C. Red D. Green

  • Loosen the 3 lower terminal screws on the terminal block. Strip wire to exposed tip about 3/8'' long.
  • Remove the ground screw and ground plate and retain them. Cut the ground strap below the ground block and discard the lower section. Insert the ground screw through the ground plate (removed earlier) and put it back into the terminal.
  • Insert the ground wire tip into the ground screw and plate. Tighten securely, but do not over-tighten (15 to 20 in-lbs).
  • Insert the center (white/neutral) wire tip through the bottom center terminal block opening. On certain models, the wire will need to be inserted through the ground strap opening and then into the bottom center block opening. Insert the two side bare wire tips into the lower left and the lower right terminal block openings.
  • Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs). Do not over-tighten the screws.

Replace the wire cover Replace the wire cover on the range back by sliding its left edge under the retaining tabs and replace the screws removed earlier. Make sure that no wires are pinched between the cover and range back.

Page 11 of the Hisense Electric Range (HER30F5CSS) user manual — Anti-Tip Bracket Install Anti-Tip Bracket (Anti-Tip Bracket Kit Included)
Page 11 · click to enlarge
Page 11

Anti-tip device installation Tip Over Hazard

Hisense Electric Range (HER30F5CSS) — Anti-tip device installation Tip Over Hazard diagram (page 11)
Fig. 25 · Anti-tip device installation Tip Over Hazard
  • Child or adult can tip the range and be killed.
  • Install the anti-tip bracket to the wall or floor.
  • Engage the range to the anti-tip bracket by sliding the range back such that the foot is engaged.
  • Re-engage the anti-tip device if the range is moved.
  • See installation instructions for details.
  • Failure to do so can result in death or serious burns to children or adults.
  • Check to make sure that the rear leveling leg is fully inserted into the Anti-Tip bracket.

Anti-Tip Bracket Install Anti-Tip Bracket (Anti-Tip Bracket Kit Included)

  • Determine which mounting method to use: floor or wall. If you have a stone or masonry floor, you can use the wall mounting method. If you are installing the range in a mobile home, you must secure the range to the floor.
  • This anti-tip bracket and screws can be used with wood or metal studs.
Hisense Electric Range (HER30F5CSS) — Anti-Tip Bracket Install Anti-Tip Bracket (Anti-Tip Bracket Kit Included) diagram (page 11)
Fig. 26 · Anti-Tip Bracket Install Anti-Tip Bracket (Anti-Tip…
  • Determine and mark the centerline of the cutout space (1). The mounting bracket can be installed on either the left-hand or right-hand side of the cutout. Position the mounting bracket against the wall in the cutout so that the center of the cutout of the bracket is 13 3/8" (34 cm) from the centerline (A).
  • Drill two 5/32" (4 mm) holes that correspond to the bracket holes of the determined mounting method.
  • Using the two 3/16 x 2" (4,8 x 50 mm) Phillips-head screws provided, mount the anti-tip bracket to the wall or floor.
  • Move range close enough to opening to allow for final electrical connections.
  • Remove shipping base, cardboard or hardboard from under range.
  • Move range into its final location, making sure the rear leveling leg slides into the anti-tip bracket (2).
Page 12 of the Hisense Electric Range (HER30F5CSS) user manual — Operation checklist
Page 12 · click to enlarge
Page 12

Level the range

Never completely remove the leveling leg as the range will not be secured to the anti-tip device properly.

  • Install the oven shelves in the oven and position the range where they will be installed.
  • Check for levelness by placing a spirit level on one of the oven shelves. Take two readings, with the level placed diagonally first in one direction and then the other.
  • First, remove the drawer.
  • Level the range by adjusting the leveling legs with a wrench.
  • The front leveling legs can be adjusted from the top or the bottom leg (1).
  • The rear legs can be adjusted from the top of the leg (2) through the drawer opening.

Final installation check list

  • Check to make sure the circuit breaker is closed or the circuit fuses are replaced.
  • Be sure power is in service to the building.
  • Check that all packaging materials and tape have been removed. This will include tape on the metal panel under control knobs (if applicable), adhesive tape, wire ties, cardboard and protective plastic. Failure to remove these materials could result in damage to the appliance once the appliance has been turned on and surfaces have heated.
  • Check that the door and drawer are parallel to each other and that both operate smoothly. If they do not, see the User Manuals for proper replacement.
  • Check to make sure that the rear leveling leg is fully inserted into the Anti-Tip bracket.

Operation checklist

  • Make sure the combustion and ventilation airflow to the range is unobstructed.
  • Be sure all range controls are in the OFF position before leaving the range.
Page 13 of the Hisense Electric Range (HER30F5CSS) user manual — ES 13
Page 13 · click to enlarge
Page 13

Tabla de contenidos

14 Antes de comenzar

15 Para su seguridad

15 Riesgo de vuelco

15 Soporte antivuelco

15 Herramientas y materiales

16 Pasos para la instalación

16 Retire los materiales de embalaje

16 Preparar la abertura

18 Instalación eléctrica

22 Instalación del dispositivo antivuelco

23 Nivelar la estufa

24 Lista de verificación final de la instalación

ES 13

Ask about the Hisense Electric Range (HER30F5CSS)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Hisense Electric Range (HER30F5CSS)

Be the first to ask — other owners or our team will answer.

Original document

Hisense Electric Range (HER30F5CSS) manual PDF

28 pages·1.9 MB·Range·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…