EN
Official user manual

BLICHMANN ENGINEERING RipTide Upgrade Kit

5 pages·136 KB·Accessory·PDF·ENDEFRITNLJA
BLICHMANN ENGINEERING RipTide Upgrade Kit
Table of Contents 11 sections RipTide™ Upgrade Kit · Assembly, Operation, & Maintenance · PLEASE READ AND THOROUGHLY UNDERSTAND THIS MANUAL PRIOR TO USE FOR · IMPORTANT SAFETY INFORMATION! · … ShowHide
Page 1 of the BLICHMANN ENGINEERING RipTide Upgrade Kit user manual — PLEASE READ AND THOROUGHLY UNDERSTAND THIS MANUAL PRIOR TO USE FOR
Page 1 · click to enlarge
Page 1
BLICHMANN ENGINEERING RipTide Upgrade Kit — RipTide™ Upgrade Kit diagram (page 1)
Fig. 1 · RipTide™ Upgrade Kit

RipTide™ Upgrade Kit

Assembly, Operation, & Maintenance

Congratulations on your purchase, and thank you for selecting the RipTide™ Upgrade Kit from Blichmann Engineering™. We are confident that it will provide you years of service and many gallons of outstanding beer.

This manual will familiarize you with the use, assembly, and the sanitation procedures for the product.

PLEASE READ AND THOROUGHLY UNDERSTAND THIS MANUAL PRIOR TO USE FOR

IMPORTANT SAFETY INFORMATION!

About This Manual:

Sections labeled “Warning” can lead to serious injury or death if not followed. Please thoroughly read these sections and understand them completely before use. If you do not understand them or have any questions, contact your retailer or Blichmann Engi- neering (www.BlichmannEngineering.com) before use.

Sections labeled “Caution” can lead to equipment damage or unsatisfactory perfor- mance of the equipment. Please read these sections thoroughly. If you have any ques- tions, contact your retailer or Blichmann Engineering (www.BlichmannEngineering. com) before use.

Sections labeled “Important” should specifically be followed to ensure satisfactory re- sults with the product.

1 RipTide Upgrade - V1 ©Blichmann Engineering, LLC 2018 For replacement parts visit blichmannengineering.com/genuine-replacemnet-parts

Page 2 of the BLICHMANN ENGINEERING RipTide Upgrade Kit user manual — RipTide™ Upgrade Kit
Page 2 · click to enlarge
Page 2
ItemPart NamePart NumberQuantity 1Rear Casing CupBE-000537-011 2Front HousingBE-000581-101 3ImpellerBE-001146-001 4Screw - Flat Standard (March)BE-000585-004 5Screw - Flat Metric (Chugger)BE-001323-004 6Retainer Clip - ValveBE-000854-021 7Tri-Clamp - 3”BE-000950-001 8WasherBE-001106-001 9Vent ValveBE-001129-001 10RipTide O-RingBE-001130-001 11Rubber FeetBE-000732-004 121/4” Cap ScrewBE-000019-004 131/4” NutBE-000029-004 141/4” WasherBE-000048-008 15RipTide Stand-Off BracketBE-001053-011 16TC Adapter BracketBE-000586-021
BLICHMANN ENGINEERING RipTide Upgrade Kit — RipTide™ Upgrade Kit diagram (page 2)
Fig. 2 · RipTide™ Upgrade Kit

2 RipTide Upgrade - V1 ©Blichmann Engineering, LLC 2018 For replacement parts visit blichmannengineering.com/genuine-replacemnet-parts

8 4/5 6

Page 3 of the BLICHMANN ENGINEERING RipTide Upgrade Kit user manual — RipTide™ Upgrade Kit
Page 3 · click to enlarge
Page 3

Assembly: To upgrade your existing pump start by removing the pump head. Ensure to not remove the magnet collar. (Fig. 1)

BLICHMANN ENGINEERING RipTide Upgrade Kit — RipTide™ Upgrade Kit diagram (page 3)
Fig. 3 · RipTide™ Upgrade Kit

DO NOT REMOVE Fig. 1

Install the 4 rubber feet to the corners of the Stand-Off Brack- et. Mount the pump to the Stand-Off Bracket with the 1/4” hardware provided. (Fig. 2)

BLICHMANN ENGINEERING RipTide Upgrade Kit — RipTide™ Upgrade Kit diagram (page 3)
Fig. 4 · RipTide™ Upgrade Kit
BLICHMANN ENGINEERING RipTide Upgrade Kit — RipTide™ Upgrade Kit diagram (page 3)
Fig. 5 · RipTide™ Upgrade Kit

Flat Head Screw Fig. 3

With the flat head screws mount the TC Adapter Bracket to your pump. (Fig. 3)

Set the Impeller inside the Rear Casing Cup and insert into the pump magnet. (Fig. 4)

BLICHMANN ENGINEERING RipTide Upgrade Kit — RipTide™ Upgrade Kit diagram (page 3)
Fig. 6 · RipTide™ Upgrade Kit
BLICHMANN ENGINEERING RipTide Upgrade Kit — RipTide™ Upgrade Kit diagram (page 3)
Fig. 7 · RipTide™ Upgrade Kit

O-Ring and Washer installed Fig. 5

Install the RipTide O-Ring and Washer to the Housing. (Fig. 5)

3 RipTide Upgrade - V1 ©Blichmann Engineering, LLC 2018 For replacement parts visit blichmannengineering.com/genuine-replacemnet-parts

Remove Head · Do Not over-tighten

Page 4 of the BLICHMANN ENGINEERING RipTide Upgrade Kit user manual — Operation:
Page 4 · click to enlarge
Page 4

Fig. 6 Mount the RipTide™ housing to your pump with the 3” Tri-Clamp. (Fig. 6)

BLICHMANN ENGINEERING RipTide Upgrade Kit — Operation: diagram (page 4)
Fig. 8 · Operation:

Operation:

Connect the pump to your system using heavy wall and/or braided hoses. It is highly recommended to use ½” ID x .125” wall silicone tubing. This hose will handle the pressures and temperatures of the beer brewing processes. Secure all hoses with clamps. If using NPT pipe fittings, always wrap the threads in Teflon tape to prevent galling of the threads. Galled threads are not covered under warranty.

Prime the pump with liquid before turning it on. Never run the pump dry! It is easiest to prime the pump when all hoses are empty, particularly hoses downstream of the pump. Open valve on the pump and then the valve on your kettle to let flow begin. If liquid does not readily flow into your pump slowly pull the ring on the vent valve to allow air to escape from the pump head. When you see liquid escape from the vent valve holes release the ring and turn on the pump.

Adjust pump flow by turning the knob on the linear flow valve.

4 RipTide Upgrade - V1 ©Blichmann Engineering, LLC 2018 For replacement parts visit blichmannengineering.com/genuine-replacemnet-parts

Do Not over-tighten

Page 5 of the BLICHMANN ENGINEERING RipTide Upgrade Kit user manual — 809-BR-HS 809-BR-HS 809-PL-HS 809-SS-HS 809-BR-HS-C 809-PL-HS-C 809-SS-HS-C 809-BR
Page 5 · click to enlarge
Page 5

Caution: As with all motors, exposure to excessive heat reduces the service life of the product. Do not exceed 125 °F (52 C) ambient air temperature. Take care when mounting near heat sources to ensure the exposure to heat is minimized and does not exceed 125 °F (52 C) when heat source is on. You should be able to comfort- ably hold your hand on the motor at all times. Failure to comply with this caution will result in damage to the equipment and may void the warranty.

After Use Cleaning and Storage:

After use completely disassemble the pump and soak the parts in PBW. Do NOT soak the motor in any liquid at any time! To clean spilled wort off of the motor, use a gentle spray of warm water and dry with a soft cloth. Then rinse the parts in hot tap water and soak the parts in StarSan. Allow the parts to air dry and reassemble the pump for storage.

Please refer to your pump manufacturer for any motor related warrantee issues. Blichmann Engineering will not cover any manufacturing defects to another manufacture’s pump.

Performance may vary.

This upgrade kit will work on the following: Chugger CPSS-IN-1 (115V) CPSS-IN-2 (230V) CPSS-CI-1 (115V) CPSS-CI-2 (230V) CPPS-IN-1 (115V) TCPSS-IN (115/230V) TCPSS-CI (115/230V)

809-BR-HS 809-BR-HS 809-PL-HS 809-SS-HS 809-BR-HS-C 809-PL-HS-C 809-SS-HS-C 809-BR

809-PL 809-SS 809-BR-C 809-PL-C 809-SS-C 815-BR 815-PL 815-SS

815-BR-C 815-PL-C 815-SS-C

Blichmann Engineering Product Warranty

A. Limited Warranty 1. Blichmann Engineering warrants to the original purchaser that this product will be free from manufacturing defects in material and workmanship for a period of one (1) year from the date of purchase by the customer. Proof of purchase is required. Blichmann Engineering’s obligation to repair or replace defective materials or workmanship is the sole obligation of Blichmann Engineering under this limited warranty. 2. The limited warranty covers only those defects that arise as a result of normal use of the product and does not cover any other problems, including, but not limited to, those that arise as a result of: a. Improper maintenance or modification; b. Damage due to incorrect voltage or improper wiring by customer; c. Operation outside of the product’s specifications; d. Carelessness or neglect to operate the product in accordance with instructions provided with the product; e. Damaging the tamper label on the product; f. Damage by over-tightening the fasteners; g. Failure to follow cleaning and / or maintenance procedures; or h. Exceeding published operational temperatures. 3. Blichmann Engineering reserves the right to request delivery of the defective component for inspection before processing the warranty claim. If Blichmann Engineering receives, during the applicable warranty period, notice of a defect in any component that is covered by the warranty, Blichmann Engineering shall either repair or replace the defective component with a new or rebuilt component at Blichmann Engineering’s option. 4. Blichmann Engineering must be notified within seven (7) days of the delivery date of any shipping damage. Customer is responsible for shipping damage outside of this time period. Approval for return must be provided by Blichmann Engineering prior to any return. Customer is responsible for keeping all original packaging material for warranty returns. Blichmann Engineering is not responsible for damage from improperly packaged warranty returns, and these repair costs will be the sole responsibility of the customer. Shipping costs for warranty returns are covered only for the contiguous United States. 5. Blichmann Engineering’s limited warranty is valid in any country where the product is distributed. B. Limitations of Warranty 1. Any implied warranty that is found to arise by way of state or federal law, including any implied warranty of merchantability or any implied warranty of fitness, is limited in duration to the terms of this limited warranty and is limited in scope of coverage to this warranty. Blichmann Engineering disclaims any express or implied warranty, including any implied warranty of fitness for a particular purpose or merchantability, on items excluded from coverage as set forth in this limited warranty. 2. Blichmann Engineering makes no warranty of any nature beyond that contained in this limited warranty. No one has authority to enlarge, amend, or modify this limited warranty, and Blichmann Engineering does not authorize anyone to create any other obligation for it regarding this product. 3. Blichmann Engineering is not responsible for any representation, promise, or warranty made by any independent dealer or other person beyond what is expressly stated in this limited warranty. Any selling or servicing dealer is not Blichmann Engineering’s agent, but an independent entity. C. Limitations of Liability 1. The remedies provided in this warranty are the customer’s sole and exclusive remedies. 2. Except for the obligations specifically set forth in this warranty, in no event shall Blichmann Engineering be liable for direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any other legal theory and whether or not advised of the possibility of such damages. 3. This warranty does not cover, and in no event shall Blichmann Engineering be liable for, travel, lodging, or any other expense incurred due to manufacturing defects in material and workmanship, or any other reason. 4. Any performance of repairs after the warranty coverage period has expired or performance of repairs regarding anything excluded from coverage after this limited warranty shall be considered good-will repairs and they will not alter the terms of this limited warranty, or extend any warranty coverage period. 5. Venue for any legal proceedings relating to or arising out of this warranty shall be in Tippecanoe County, Indiana, United States, which courts will have exclusive jurisdiction. D. Local Law 1. This warranty gives the customer specific legal rights. The customer may also have other rights that vary from state to state in the United States or other countries. 2. To the extent that this warranty is inconsistent with local law, it shall be deemed modified, only to the extent necessary to be consistent with such local law.

5 RipTide Upgrade - V1 ©Blichmann Engineering, LLC 2018 For replacement parts visit blichmannengineering.com/genuine-replacemnet-parts

March

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the BLICHMANN ENGINEERING RipTide Upgrade Kit

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the BLICHMANN ENGINEERING RipTide Upgrade Kit

Be the first to ask — other owners or our team will answer.

Original document

BLICHMANN ENGINEERING RipTide Upgrade Kit manual PDF

5 pages·136 KB·Accessory·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…