Congratulations on choosing the Phonak RemoteControl.
Please read the user guide carefully to make sure that you understand and get the best out of your remote control.
For more information about features and benefits, simply contact your hearing care professional.
! Compatibility information: Check your hearing aid compatibility with your hearing care professional.
Phonak – life is on www.phonak.com

1. Description 6 2. Using phonak RemoteControl 7 2.1 Activating the Phonak RemoteControl 7 2.2 Switching On/Off 7 2.3 Understanding the indicator light 7 2.4 Pairing the Phonak RemoteControl with your hearing aid 8 2.5 Changing hearing aid volume 9 2.6 Changing hearing aid program 10 3. Inserting a new battery 11 3.1. Open the battery compartment 11 3.2. Remove the battery from the battery compartment 11 3.3. Insert the new battery 11 3.4. Close the battery compartment 12 4. Reset the Phonak RemoteControl 13 5. Troubleshooting 14

2. Using Phonak RemoteControl
The intended user of the Phonak RemoteControl is to enable changes of your hearing aid programs and volume.
2.1 Activating the Phonak RemoteControl Pull out the battery protective tab to activate your Phonak RemoteControl.
2.2 Switching On/Off Use the slider to switch on or off.
2.3 Understanding the indicator light
Solid green for 3 seconds Switched on, ready to use Blinking blue Paring mode
Solid green for 5 seconds Pairing successful Solid red for 5 seconds Paring failed Solid green for 1 second Confirmation of push button press Solid orange Battery warning Solid red General device error Solid green for 3 seconds Reset successful
The Phonak RemoteControl must be paired with your
hearing aids before you can use it (chapter 2.4).

2.4 Pairing the Phonak RemoteControl with your hearing aids
1. Press and hold the volume up “+” button 2. Switch on your Phonak RemoteControl whilst still pressing the volume up “+” button 3. Release the volume up ”+” button when the light indicator starts to blink blue 4. The Phonak RemoteControl and your hearing aids will now pair automatically 5. After a successful pairing the light indicator is solid green for 5 seconds and you may hear a notification beep in your hearing aid 6. You can now use your Phonak RemoteControl
To use your Phonak RemoteControl with your hearing aids, you must first pair the hearing aids.
It is only necessary to perform the pairing procedure
once with your hearing aids. After the initial pairing, your Phonak RemoteControl will connect automatically with your hearing aids.
The Phonak RemoteControl will be automatically in the
pairing mode if switched on for the first time. This is indicated by the blinking blue light indicator on your Phonak RemoteControl.
2.5 Changing hearing aid volume
Set your hearing aids into the pairing mode by switching them on. You now have 3 minutes to pair your Phonak RemoteControl with your hearing aids.
Press “+” to increase volume
Press “–” to decrease volume

2.6 Changing hearing aid program
3.1. Open the battery compartment

Each press of the program button will switch your hearing aids to the next available program.
Press to change the hearing aid program

Changes are applied to both hearing aids at the same
hearing care professional to print your Phonak RemoteControl instructions.

3.4. Close the battery compartment
A reset of your Phonak RemoteControl will remove the
pairing to your hearing aids.
Press the volume up “+” button and the program change button for more than 10 seconds.
Keep batteries out of reach of children, mentally

Problem No indicator light when a button is pressed Hearing aids do not respond to the RemoteControl commands
Causes Remote control is switched off Battery is empty Hearing aids are switched off Hearing aids are not paired with your RemoteControl Remote control is switched off Battery is empty General device error
What to do Switch on your remote control (chapter 2.2) Change battery (chapter 3) Switch on your hearing aids (see hearing aid user guide) Pair the RemoteControl (chapter 2.4)
Switch on your remote control (chapter 2.2) Change battery (chapter 3) Reset your RemoteControl (chapter 4) and pair your hearing aids (chapter 2.4)
Solid red light indicator
If the problem persists, contact your hearing care
professional for assistance.

Declaration of conformity Hereby Phonak AG declares that this Phonak product is in compliance with the essential requirements of the Medical Device Regulation (EU) 2017/745 as well as the Radio Equipment Directive 2014/53/EU. The full text of the EU Declaration of Conformity can be obtained from the manufacturer or the local Phonak representative whose address can be taken from the list on https://www.phonak.com/com/en/certificates.html (Phonak worldwide locations).
The following model is certified under:
Australia/New Zealand:
Indicates a device’s compliance with applicable Radio Spectrum Management’s (RSM) and Australian Communications and Media Authority (ACMA) regulatory arrangements for the legal sale in New Zealand and Australia. The compliance label R-NZ is for radio products supplied in the New Zealand market under conformity level A1.

Radio information of your wireless device
Antenna type Operation frequency Modulation Radiated power Bluetooth® Range Bluetooth Profiles supported
Monopole antenna 2.4 GHz – 2.48 GHz GFSK < 2.8mW
~1m 4.2 BLE (GATT)

Compliance with emission and immunity standards
Emission standards EN 60601–1-2:2015 IEC 60601–1-2:2014 EN 55011:2009+A1 CISPR11:2009/AMD1:2010 CISPR22:1997 CISPR32:2012 ISO 7637-2:2011 CISPR25:2016 EN 55025:2017
Immunity standards EN 60601-1-2:2015 IEC 60601-1-2:2014 EN 61000-4-2:2009 IEC 61000-4-2:2008 EN 61000-4-3:2006+A1+A2 IEC 61000-4-3:2006+A1+A2 EN 61000-4-4:2012 IEC 61000-4-4:2012 EN 61000-4-5:2014 IEC 61000-4-5:2014 EN 61000-4-6:2014 IEC 61000-4-6:2013 EN 61000-4-8:2010 IEC 61000-4-8:2009 EN 61000-4-11:2004 IEC 61000-4-11:2004 IEC 60601-1 (§ 4.10.2):2005 ISO 7637-2:2011

Additional information can be found in the Data Sheet of your product.
Any serious incident that has occurred in relation to the device should be reported to the manufacturer representative and the competent authority of the state of residence. The serious incident is described as any incident that directly or indirectly led, might have led or might lead to any of the following:
For any information regarding the repair service of the hearing aid accessories please contact the hearing care professional.
Intended use: The intended use of the Phonak RemoteControl is to enable changes of the hearing aid programs and volume.
- the death of a patient, user or other person - the temporary or permanent serious deterioration of a patient‘s, user‘s or other person‘s state of health - a serious public health threat
To report an unexpected operation or event, please contact the manufacturer or a representative.
Diligent and routine care of your Phonak RemoteControl contributes to outstanding performance and a long service life. To ensure a long service life, Sonova AG provides a minimum of a five year service period after phase out of the respective product.
Target population: Target group are people with hearing loss wearing compatible Phonak hearing aids. No restrictions on the hearing loss level.
Phonak RemoteControl is suitable for the home healthcare environment and due to their portability it may happen that it is used in professional healthcare facility environment like physician offices, dental offices etc.
For more information regarding features, benefits, setup, use and maintenance or repairs of your accessories – contact your hearing care professional or manufacturer representative.

With the CE symbol, Sonova AG confirms that this product – including accessories – meets the requirements of the Medical Device Regulation (EU) 2017/745 as well as the Radio Equipment Directive 2014/53/EU. The numbers after the CE symbol correspond to the code of certified institutions that were consulted under the above-mentioned directives.
This symbol indicates that it is important for the user to read and take into account the relevant information in these user guides.
This symbol indicates that it is important for the user to pay attention to the relevant warning notices in these user guides.
This symbol indicates that the products described in these user instructions adhere to the requirements for an applied part of Type B of EN 60601-1.
This symbol confers that the electromagnetic interference from the device is under limits approved by the US Federal Communications Commission.
Indicates the medical device manufacturer, as defined in Medical Device Regulation (EU) 2017/745.
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Sonova AG is under license. Other trademarks and trade names are those of their respective owners.
Indicates the Authorized representative in the European Community. The EC REP is also the importer to the European Union.

Japanese mark for certified radio equipment.
Humidity during storage: 0% to 70%, if not in use.
Indicates the manufacturer’s serial number so that a specific medical device can be identified.
Atmospheric pressure during transportation, storage and operation: 500 hPA to 1060 hPa.
Indicates the manufacturer’s catalogue number so that the medical device can be identified.
During transportation keep dry.
The symbol with the crossed-out garbage bin is to make you aware that this device may not be thrown away as normal household waste. Please dispose of old or unused device, at waste disposal sites intended for electronic waste, or give your device to your hearing care professional for disposal. Proper disposal protects the environment and health.
This symbol indicates that it is important for the user to read and take into account the relevant information in this user guide.
The device is a medical device.
Temperature during transportation and storage: –20° to +60° Celsius (–4° to +140° Fahrenheit). Temperature operation: 0° to +40° Celsius (+32° to +104° Fahrenheit)

Please read the information on the following pages before using your device
If problems occur which cannot be resolved by
following the remedy guidelines in the troubleshooting section of this user guide, consult your hearing care professional.
8.1 Hazard warnings
Your device operate between 2.4 GHz–2.48 GHz
This device is not for children below 36 months. The
frequency range. When flying please check if flight operator requires devices to be switched off.
usage of this device by children and individuals with cognitive impairment should be supervised at all times to ensure their safety. It is a small device and contains small parts. Do not leave children and individuals with cognitive impairment unsupervised with this device. If swallowed, consult a physician or hospital immediately as the device or its parts can cause choking!
Keep this device out of reach of children aged under
3 years and mentally challenged people or pets.
This remote control uses low-power, digitally coded
transmission to communicate to your hearing system. Although unlikely, interference with medical devices (i.e. pacemakers, defibrillators, etc.) is possible. Therefore users must not keep this remote control in or near a breast pocket.
Use of this equipment adjacent to or stacked with
other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
Changes or modifications to the device that were not
explicitly approved by Sonova are not permitted. Such changes may damage your device.
Remove the battery if you are not using the device
for a long period of time.

Do not use the device in explosive areas (flammable
8.2 Information on product safety
anesthetics, mines or industrial areas with a danger of explosions), oxygen rich environments or where electronic equipment is prohibited.
Protect the device from excessive moisture (bathing,
swimming), heat (radiator, car dashboard) or direct skin contact when sweating (workout, fitness, sport).
Use of accessories, transducers and cables other than
Do not drop the device. Dropping onto a hard
those specified or provided by the manufacturer of this equipment could result in increased electro- magnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.
surface can damage your device.
Special medical or dental examination including
radiation described below, may adversely affect the correct functioning of your device. Remove and keep it outside the examination room/area before undergoing: • Medical or dental examination with X-ray
Portable RF communications equipment (including
peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the Phonak RemoteControl including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.
(also CT scan). • Medical examinations with MRI/NMRI scans,
generating magnetic fields.
Protect the device sockets and battery slot from dirt
and debris.

The digitally-coded, transmission technology used in
8.3 Other important information
the device is highly reliable and experiences virtually no interference from other devices. It should be noted, however, that when operating the hearing system near computer equipment, larger electronic installations or other strong electromagnetic fields, it may be necessary to be at least 60 cm (24”) away from the interfering device to ensure proper operation.
High-powered electronic equipment, larger electronic
installations and metallic structures may impair and significantly reduce the operating range.
If the hearing aids do not respond to the device
because of an unusual field disturbance, move away from the disturbing field.
Keep the device at least 10 cm away from any kind of
magnets.
When the device is not in use, turn it off and store it
safely.
Do not use your device in areas where electronic
equipment is prohibited.

10. Service and warranty
Cleaning of the device
10.1 Local warranty Please ask the hearing care professional, where you purchased your devices, about the terms of the local warranty.
Use a lint-free cloth for cleaning. Dry cleaning is preferred. If necessary, the surface can be cleaned with mild soapy water. However, the cloth should be damp and not dripping wet to prevent moisture from entering the device. Do not use aggressive substances such as solvents or paint thinners as these can impair the surface.
10.2 International warranty Sonova offers a one year limited international warranty, valid as of the date of purchase. This limited warranty covers manufacturing and material defects. The warranty is valid only if proof of purchase is shown.
The international warranty does not affect any legal rights that you might have under the local warranty or the applicable national legislation governing sale of consumer goods.

10.3 Warranty limitation This warranty does not cover damage from improper handling or care, exposure to chemicals or undue stress. Damage caused by third parties or non-authorized service centers renders the warranty null and void. This warranty does not include any services performed by a hearing care professional in their office.
Serial number:
Date of purchase:
Authorized hearing care professional (stamp/signature):



029-0856-02/V1.00/2020-06/cl © 2020 Sonova AG All rights reserved
Your hearing care professional:
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.